Loading...
Report (35) FPSZo0 / 17 FIRE ALARM SYSTEM RECORD OF COMPLETION Name of protected property: Solid Rock Church (Scholls Bus Park Bldg T) Address: 10500 SW Nimbus Portland Or 97223 Representative of protected property(name/phone): KK Investment Properties 503-598-9980 Authority having jurisdiction: City of Tigard Address/telephone number: 13125 SW Hall Blvd, Tigard OR 97223 1. Type(s)of System or Service NFPA 72,Chapter 3—Local If alarm is transmitted to location(s)off premises,list where received: NFPA 72,Chapter 3—Emergency Voice/Alarm Service Quantity of voice/alarm channels: Single: Multiple: Quantity of speakers installed: Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: NFPA 72,Chapter 6—Auxillary Indicate type of connection: Local energy Shunt Parallel telephone Location of telephone number for receipt of signals: NFPA 72,Chapter 5—Remote Station Alarm: Supervisory: NFPA 72,Chapter 5—Proprietary If alarms are retransmitted to public fire service communications centers or others,indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: ✓ NFPA 72,Chapter 5—Central Station Prime contractor: Action Technology Systems LLC Central station location: CSM Estacada, Oregon Means of transmission of signals from the protected premises to the central station: McCulloh Multiplex ✓ One-way radio Digital alarm communicator Two-way radio Others Means of transmission of alarms to the public fire service communications center: (a) (b) System location: I1�l:(R' eAk \CCM (NFPA Record of Completion 1 of 4) Organization name/phone Representative name/phone Installer Action Technology Systems LLC Steven A Barry/503-231-1992 Supplier AES (800) 237-6387 Service organization Action Technology Systems LLC Steven A Barry/503-231-1992 Location of record(as-built)drawings: Owner Rep &Action Office Location of owners manuals: Document Can adjacent Panel in Riser Room Location of test reports: Document Can adjacent Panel in Riser Room A contract,dated ,for test and inspection in accordance with NFPA standard(s) No(s). ,dated ,is in effect. 2. Record of System Installation (Fill out after installation is complete and wiring checked for opens,shorts,ground faults,and improper branching,but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below,was inspected by Action Technology on 12-2-2019 ,includes the devices shown below,and has been in service since 12-2-2019 ✓ NFPA 72,Chapters 1 2 3 4 5 6 7 (circle all that apply) L.NFPA 70,Nations" . trical Code,Article 760 L.Manufacture'r's instruc ions • ther(s r•cify): i S' ed: Date: 12-2-2019 or • iofi:'"`tion Technology Systems LLC 3. Record of System Operation All operational features and functions of this system were tested by Action Technology on 12-2-201j and found to be operating properly in accordance with the requirements of: ✓ NFPA 72,Chapters 1 2 3 4 5 6 7 (circle all that apply) ✓ NFPA 70/ationa. Electrical Code,Article 760 ✓ Manuf. turer's intructions ether cify): Si! ed: ► L Date: 12-2-2019 Orga ' in: Action Technology Systems LLC 4. Alarm-Initiating Devices and Circuits Quantity and class of initiating device circuits(see NFPA 72, Table 3-5) Quantity: Style: Class: MANUAL (a) 10 Manual stations Noncoded,activating Transmitters Coded (b) Combination manual fire alarm and guard's tour coded stations AUTOMATIC Coverage: Complete: Partial: (a) 34 Smoke detectors Ion 34 Photo (b) 9 Duct detectors Ion 9 Photo (c) 1 Heat detectors FT RR FT/RR RC (NFPA Record of Completion 2 of 4) (d) I Sprinkler waterflow switches: Transmitters Noncoded,activating Coded (e) Other(list): 5. Supervisory Signal-Initiating Devices and Circuits (use blanks to indicate quantity of devices) GUARD'S TOUR (a) Coded stations (b) Noncoded stations,activating transmitters (c) Compulsory guard tour system comprised of transmitter stations and intermediate stations Note: Combination devices are recorded under 4(b)and 5(a). SPRINKLER SYSTEM (a) 2 Coded valve supervisory signaling attachments Value supervisory switches,activating transmitters (b) Building temperature points (c) Site water temperature points (d) Site water supply level points Electric fire pump: (e) Fire pump power (f) Fire pump running (g) Phase reversal Engine-driven fire pump: (h) Selector in auto position (i) Engine or control panel trouble (j) Fire pump running Engine-driven generator: (k) Selector in auto position (1) Control panel trouble (m) Transfer switches (n) Engine running Other supervisory function(s)(specify): 6. Alarm Notification Appliances and Circuits Quantity and class(see NFPA 72,Table 3-7)of notification appliance circuits connected to the system: Types and quantities of notification appliances installed: Quantity: 4 Style: Y Class: B (a) Bells Inch (b) Speakers (c) Horns (d) Chimes (e) Other: (NFPA Record of Completion 3 of 4) e (f) 30 Visual signals Type: 30 with audible w/o audible (g) 1 Local annunciator 7. Signaling Line Circuits Quantity and class(see NFPA 72, Table 3-6)of signaling line circuits connected to system: Quantity: 1 Style: �' Class: B 8. System Power Supplies (a)Primary(main): 110vac Nominal voltage: 24vdc Current rating: 10amps Overcurrent protection: Type: Current rating: Location: Main Electrical Room (b)Secondary(standby): ✓ Storage battery: Amp-hour rating: 7.Oah Calculated capacity to drive system,in hours: X 24 60 Engine-driven generator dedicated to fire alarm system: Location of fuel storage: (c)Emergency or standby system used as backup to primary power supply,instead of using a secondary power supply: Emergency system described in NFPA 70,Article 700 Legally required standby system described in NFPA 70,Article 701 Optional standby system described in NFPA 70,Article 702,which also meets the performance requirements of Article 700 or 701 9. System Software (a)Operating system software revision level(s): (b)Application software revision level(s): (c)Revision completed by: (name) (firm) 1'. Co - • (sign•. or central station or alarm service company or installation contractor/supplier (title) (date) Frequency of routine tests and inspections,if other than in accordance with the referenced NFPA standard(s): System deviations from the referenced NFPA standard(s)are: (signed)for central station or alarm service company or installation contractor/supplier (title) (date) Upon completion of the system(s)satisfactory test(s)witnessed(if required by the authority having jurisdiction): (signed)representative of the authority having jurisdiction (title) (date) (NFPA Record of Completion 4 of 4)