Loading...
Report 6‘,,,ggo scAI SuidsocJ • co4-sr sr tviSTZ0c9-00278 C T ENGINEERING INC 180 Nickerson St. Suite 302 Seattle,WA 98109 (206)285-4512(V) (206)285-0618(F) asolomon@ctengineering.com BULLETIN Date: July 19,2019 Number:CT-59 Project#: 15238 Project Name: River Terrace SF Attached: None Subject: Plan 7ABD—Shearwall Clarifications Drawings Affected: Description/Action: This bulletin provides response to RFI, design clarifications and/or variation requests for the 'River Terrace SF' project located in Tigard, Oregon. For plan types 7A, 7B and 7D, the front living room shearwalls (first floor) are P2 shearwalls and the rear garage braced wall panel shearwalls (first floor) are P3 shearwalls. The structural calculations incorrectly show that the living room walls are double-sided 2P3 shearwalls and the garage braced wall panels are double-sided 2P4 shearwalls. ,<</e. G I N4-f, 0 W � • a_t` 4REG6NA V/ 22��01<<c/� PleS T, 07/19/2019 CALL WITH ANY OUESTIONS Issued by: Arnold R. Solomon Date: July 19. 2019 Distribution: Contact Information: Allvson Armstrona City of Tiaard David Burnett Milbrandt Architects R:\15238 River Terrace SF\Bulletins\15238_2019.07.19_CT59_Plan 7ABD-Shearwall Clarifications.doc Structural Engineers