Horn Consulting Engineers LLC
ry
Structural Calculations OFFICE COPY P : IED
criv.C1
HCE Project#: JTS:19-33 D 1 7 2019
•
BUILDING V sj
Date: 10/15/2019
O
Project Description: New House:
Tigard, Oregon
Red Cedar Estates Plan 2596C Lot#7
Subject Sheet#'s
Lateral Loads L1 — L7
Framing F1 — F5
Susp. Garage SG1 — SG2
Deck Framing D1
Footings FTG1
Retaining Wall RW1 — RW15
•;O'` ROi
NEFJ.'oy
5 C19PE
• r-
0 10N
t </ `
O qN 12 1°'�'
41/0 NpQ\
Expires: 6-30-21
The following calculations are for lateral wind and seismic engineering and gravity loading of the beams and columns. The design is based on
information provided by the client who is solely responsible for its accuracy. The engineering represents the finished product. Discrepancies from
information provided by the client invalidate this design. Horn Consulting Engineers shall have no liability(expressed, or implied),with respect to the
means and methods of construction workmanship or the actual materials used in construction.
Horn Consulting Engineers shall have no obligation of liability,whether arising in contract(including warranty),Tort(including active, passive,or imputed
negligence)or otherwise,for loss or use,revenue or profit,or for any other incidental or consequential damage.
7412 SW Beaverton-Hillsdale HWY Portland, OR 97225
Phone: 503.892.5782 Email:dave@hornce.com
l !AlHCE
Horn Consulting Engineers LLC
New House: JTS-19-33 GL
Code Basis of Design: 2014 O.R.S.C. and 2017 O.R.S.C.
Wind Loading: Per ASCE 7
Fig 28.6-1
See attached elevations for wind loading breakdown per level.
120mph 3-sec gust Exp B.
The mean roof height of the house
h = 26' approximately.
414144 (i"
# 0
; , -
SIC 4 111.1c
Case A
Case B
a = .10*40' = 4.0'
or for h = 26'
a = .4(h) = .4(26') = 10.4'
a must be larger than .04(40') = 1.6' or 3'
a =4.0' controls
Therefore:
2a = 8' see Fig 28.6-1 ASCE 7, and Figure above.
7412 SW Beaverton-Hillsdale Hwy,Ste 202 Portland,OR 97225
Phone:503.892.5782 Email:dave@hornce.com
_ CZ
000-144-
i111211
i11 I HCE
H r Consulting Engineers LLC
Seismic Loading: D1 seismic design category per O.R.S.C.
Sps= .72, R = 6.5, W=weight of structure
V = [1.2 Sps/(R x 1.4)]W
V= .095W
Roof Dead load = 15 psf
Exterior Wall Dead load = 12 psf
Interior Wall Dead load = 8 psf
Floor Dead load = 12 psf
Seismic in Front to Back:
Wr= [.095(37')(15+6+4)] = 87.9plf > 60.6plf therefore, seismic governs.
W1 = [.095(45')(12+12+8)] + 87.9 = 224.7plf > 199.9plf therefore, seismic governs.
W1 = [.095(14')(12+10+6)]+[.095(10')(60)] + 224.7 = 318.9plf > 309.9plf therefore, seismic governs.
Seismic in Side to Side:
Wr= [.095(40')(15+6+4)] = 95p1f > 61.8plf therefore, seismic governs.
W1 = [.095(40')(12+12+8)] + 95 = 216.6plf > 203.3plf therefore, seismic governs.
W1 = [.095(30')(12+10+6)] +[.095(10')(60)] + 216.6 = 353.4plf > 304.6plf therefore, seismic governs.
Redundancy Factor= 1.0 per ASCE7 section 12.3.4.2
7412 SW Beaverton-Hillsdale Hwy,Ste 202 Portland,OR 97225
Phone:503.892.5782 Email:dave@hornce.com
HCE
Horn Consulting Engineers LLC
Roof Diaphragm:
Left Wall Line Back Wall Line
PW = (0.0606) klf x 20' = 1.2k P = (0.095) klf x 14' = 1.3k
PS = (0.0879) klf x 20' = 1.8k V= P/(24)' = 55plf Type A Wall
V = Pj(34)' = 52p1f Type A Wall 4' Wall
11' Wall Mot = 1.8kft
Mot = 4.6kft Mr = 3.3(0.6) = 2.0kft No HD Req'd
Mr = 14.9(0.6) = 9.0kft No HD Req'd
Front Wall Line
Right Wall Line P = (0.095) klf x 20' = 1.9k
PW= (0.0606) klf x 20' = 1.2k V = P/ (10.5)' = 181 plf Type A Wall
PS = (0.0879) klf x 20' = 1.8k 10.5' Wall
V = PJ (17)' = 103pIf Type A Wall Mot = 15.2kft
17'Wall Mr= 13.9(0.6) = 8.3kft
Mot = 14.1 kft T = 0.7k Type 8 HD
Mr= 35.4(0.6) = 21.2kft No HD Req'd
Front Wall Line @ Bump Outs
P = (0.095) klf x 10' = 1.0k
V= P/(12.25)' = 78plf Type A Wall
2.75' Wall
Mot = 1.7kft
Mr = 2.0(0.6) = 1.2kft
T = 0.2k No HD Req'd
7412 SW Beaverton-Hillsdale Hwy,Ste 202 Portland,OR 97225
Phone:503.892.5782 Email:dave@hornce.com
lI H
HOM Consulting Engineers LLC
Upper Floor Diaphraqm:
Left Wall Line Back Wall Line @ Bump Out
P, = (0.1393) klf x 20' + 1.2k=4.0k P = (0.1216) klf x 2' = 0.2k
PS = (0.1368) klf x 20' + 1.8k = 4.5k V= P/ (9)' = 27p1f Type A Wall
V = Ps/(27)' = 168plf Type A Wall 4'Wall
27'Wail Mot = 1.0kft
Mot = 40.8kft Mr = 3.3(0.6) = 2.0kft No HD Req'd
Mr = 70.4(0.6) = 42.2kft No HD Req'd
Back Wall Line
Right Wall Line P = (0.1216) klf x 13' + 1.3k = 2.9k
PW= (0.1393) klf x 20' + 1.2k =4.0k V = P/ (10.5)' = 274p1f Type B Wall
PS = (0.1368) klf x 20' + 1.8k = 4.5k 3.25' Wall
V = Ps/(29)' = 156plf Type A Wall Mot = 8.0kft
29'Wall Mr = 2.6(0.6) = 1.6kft
Mot = 40.8kft T = 2.0k Type 8 HD Above
Mr = 80.1(0.6) =48.1kft No HD Req'd Type 1 HD Below
Interior Wall Lines
P = (0.1216) klf x 23.25' + 1.9k = 4.7k
V = P/ (20)' = 236plf Type A Wall
10' Wall
Mot = 21.3kft
Mr= 14.6(0.6) = 8.8kft
T = 1.3k + 0.7k = 2.0k Type 8 HD
Front Wall Line
P = (0.1216) klf x 8.25' + 1.0k = 2.0k
V= P/ (11)' = 182plf Type A Wall
2.5'Wall
Mot = 3.2kft
Mr= 1.7(0.6) = 1.0kft
T = 0.9k Type 1 HD
7412 SW Beaverton-Hillsdale Hwy,Ste 202 Portland,OR 97225
Phone:503.892.5782 Email:dave@homce.com
ll HE
Horn Consulting Engineers LLC
Main Floor Diaphragm:
Left Wall Line Back Wall Line
PW= (0.110) klf x 20' + 4.0k = 6.2k P = (0.1368) klf x 12' + 2.9k + 0.2k = 4.7k
Ps = (0.0942) klf x 20' +4.5k= 6.4k V= P/ (40)' = 119plf Type A Wall
V = Ps/(43)' = 149p1f Type A Wall 15' Wall
16' Wall Mot = 10.7kft
Mot = 11.8kft Mr = 18.3(0.6) = 11.0kft
Mr = 18.8(0.6) = 11.3kft
T = 0.0k Back Wall Line @ Garage
P = (0.1368) klf x 18' + 4.7k/2 = 4.8k
Right Wall Line V = P/ (14)' = 344p1f Type B Wall
PW = (0.110) klf x 20' + 4.0k = 6.2k 14'Wall
Ps = (0.0942) klf x 20' +4.5k= 6.4k Mot = 19.3kft
V = Ps/(45)' = 142p1f Type A Wall Mr = 39.9(0.6) = 24.Okft
45'Wall
Mot = 32.Okft
Mr= 107.6(0.6) = 64.5kft
7412 SW Beaverton-Hillsdale Hwy, Ste 202 Portland,OR 97225
Phone:503.892.5782 Email:dave®a hornce.com
A=ce -4. /20Awl/ Exp• $ i-Sec. G.KST
20•'1.0 a /Z.s ksn
1 ; 1 (.V, - o.' As"
A AAA., Z(r' .,
HIGHEST RIDGE
25E 314'
TOPOFPLPTE. - ---- /._-.. N ./S'\ wV (0040 sr"
in h_i st
NpN
,...—
O .
,8'3118^OR _ Aafilii................w.i. wz.. 139.3 '"4
B'-1,18• ..�...... _. ..__._._.___._._._.
z IrvA ► A $
ttLLLL•m � - 11120r11111
•►ITF o� IIII�IIr111111-�_ =aw,: yo /.
—....,
"431
11.47 53,3 ?t.k'
wcz= -1 r---14w..% (00.tesi - _
, Z./` 9' 13'43 . 93.00 /3•/.3 n
Lot'' nii1VG.= //0 */• 6
140.1 11%.1) . 11°4 $, 2.41' S•
_ IAYL.. t3`t•3 *Y
Wet w
g• VK• 8'
W>tz s 1-0(94 _ $0.(4 ' Asce -4. t2a viPN cal. b 3-set" 4145T
a% Po A , zl-I)(4's am As
es z3 ' $4 0
G2 zo- ('(V. rz-s '4sa
104rv4. 26'-0"
HIGHES26'4 3/4T RIDGE
"
il I e f..
CA).r. L91-°o HA -g p g
TOP OF PLATE
IZ:le .)
m
2N0 FLOOR
/41
TOP OF PLATE
1.- corz.e0Avt 1 Fill
t
1ST FLOOR 4, a1
GARAGE SLAB
t..ao: 101.3'��
V.Z7—\ i
I r
i
I
Ti-(0 'tt to 171.5 51s l01:g
_ 53•brV
W&' 1 1 j�'� F-1 AvL.= ( i-"o 11. W{_ • AVL•=
$• Zi, (2' Y ll
--' g' z '
S' U. t l'
4:� PROJECT .A'S'S'' 1'1--3A SHEET TI
/\1111 HCEDATE 1-Ir--?
r�N
SUBJECT ItA•I+ BY ��
Horn Consulting Engineers LLC
x i 13 ^ "a4s(z.4 = a,31.,1` P3,, ovv�z)Z1 1,1k3
ii ;6 .- 4 • tip i'-) - o3A:
,c � �. R�3A a�' �
31 41 t,,v p -�34t)4.#l(z'+ ',1(�) 4,1- 4‘ I4U.
4, 41
4' W--. v .aak1 ) 1713(P) Z .).4...i.
. p-, cp. t-(-1) = 1 :)‘i
Li 2- 23e I) 4.-----
n-, a.%i- z 1:)1°
X
' k IV.
1 IP
iz
p- ►l,vk oa
�' �ti> --- � ' 2' 1.
5 . 1 ( 9 N.s 1.r°364.-
NaZ GT. 4►? sL 6L fix 9 '
GI-
141445' -.Z(aS Cix;) CI.1 17,1 SL
I i44 I L` 6.s yv,-,a s c e-t-) - 4447, ij , I,
Z 1.43*'' 3.i... . \ \ .5.01v
kr; .44(A) t 1- (it-t 1.43(zsz 2S = 5. .9k
6;L' Z A. ` 1
,�� It A �k •7 k(4)'-i.' 10,E
�L
(a.1CM) ' 3
i4alp z,9
a 3 -Ii-,A, l 4'--
9320 SW BARBUR BLVD. SUITE 135 • PORTLAND, OR • 97219
I
PHONE: 503.892.5782 • EMAIL: DAVE@HORNCE.COM
/% PROJECT..9rri't—VS' SHEET fl
1►I/li H C EDATE 1—,r-)MSUBJECT flEIMAArtBY Jj
Horn Consulting Engineers LLC
BEcs 6 (t)4 ,cte}I i, ( 3 v/i
ops � ��� �) % 1,4
_____ ? .4�4.-1.:�
r‘-- 1,13 C i, 1 e- h.-k Ail:L._-,____
-z.
I IA 61 Lr, i\., t�,i.,QfC La6�z3 = AS44 �� Saki
\Ne-7,4* .1'SS (71'S 'Ii?..4S *..P11(-12.74,'"Fal: t1,31( e I,ck 1
Lv-5 4 $:c'
' A g(S- /--1,—k 9'Cr c--.).-f- ,t3(Ts,6 12A' , 3314
,6.S
4, T , z, WO-2-1^
1, -7,3(,6 - ,16(tri.. S *1° 6/_ s ikx i €rii_*----
iv) IY= a� �i'. D � ., TP4S C? o1Z',.),acs .f. (,::6 ,r: "T41,1- #= 2,"ZS .
L-- ` ds �,JZ ; I('
yv--�.5 (1)- y S
14- 14
2- L►r4 Ph.?1q
1
x ' 145 4 S P.� .2k S,`k
I.
1? 133 1 1,CY'
M 3 3L') 4. 3.- \ ',\ �,
Ate'°• i.0 (3.3� ^ ),c it.
d.1 . 3 q-xto i-
7.3 Co-) _ 44_1(,
Agan O.°1
9320 SW BARBUR BLVD. SUITE 135 • PORTLAND, OR • 97219
PHONE: 503.892.5782 • EMAIL: DAVEI HORNCE.COM
�\ PROJECT a is- 11- 1 S SHEET 13
MNHCE DATE q",C-!9
SUBJECT r-►r11?4 BY bad
Horn Consulting Engineers LLC
1
I fief 6 s1 t ��k
,
L fz
P / ,.
'L .-os C1") L `�' N % N %
f.
,°►�� 1' .d�� '� ' 6�s� - e�S -3
6 -�. (.�S Shad '1 (1JZ )
k..?(,I4s
9320 SW BARBUR BLVD. SUITE 135 • PORTLAND, OR • 97219
PHONE: 503.892.5782 • EMAIL: DAVE®HORNCE.COM
.eiN PROJECT .515" ) -3% SHEET f4
IONHCESUBJECTAA^ DATE 1-is -19 Horn Consulting Engineers LLC BY
Z
ll 4 2C W= , ivC ji L 1 C D .rcb , t
7---, .1 s-1, (2-4) c,-*--. �
,ICDA
z 1 '2'-L-'
JL24 L7 I yvr ,ot‘l. 2-5J11 d `l3 f, 64 x I1 .
t i 2.7.Y.rd.1.3( -")i Z,
N d43Gi 3"411
4r
GA 10 W4 a a..SS f31111.14
0.914x, -r , 3-4.Zv�3 —/4
X g,, „,..orl(b)Z 4` 1�� 6.1- 1J‘-14/
J.11(tc) 'N. ' 1 Z•� 971e
try-G ),(C.11)ii T" 1T.41. 1 ,r__________F_Tiqt Oroes41(
' 4
IT,i L-i to.5 it
5,�-Ri a0k 1 �•�
IV . .d4S(0t.oss (nh,>-r, p.m (1) , .$$k0, , e _ . L 111.2,-
ci
•%S( 1i in(1 -f- I.p)6x) 9► �s' _i.`
isi /-42-a‘ W, = .0cs (1.6/4) is'1,111' „c4-01 ?Akt .41N,
= �j1, }7= E-t
w ..')S (310-t�.0).4.6+,4e) J s
-z 1
Ait
r ,_ ,i7) ? ..1,—/(n)ii g A. 63)4.4`)<T)1VC \ ‘ %
F-- FelV 111 31
F =2,00
L .L1 ki
th-;- Wil(-6- t`r)(' ) 2. 1*. 2-4-.10 . i c‘ 0 1-‘,41, 64_ eix W. .1
9320 SW BARBUR BLVD. SUITE 135 • PORTLAND, OR • 97219
PHONE: 503.892.5782 • EMAIL: DAVE@HORNCE.COM
e�\ PROJECT 5 tS-• 11- '1 SHEET tS
/►%1 HCEp mDATE 9-3-19
SUBJECT Tp -s , BY .114.44Horn Consulting Engineers LLC
K. Lc- 14 *ill .oA S s"�.},41. (1 -1. .o S S f zJ +,o4 S 4 1,LS
lc. LZ
r
(� s% xib_
' i a. 2�C
-7 L_ ') , a 1^s i 2Y/1 Sia 1:23(-1-
-A A t4 Z, 1
p,, .-z (.+ Z < Mk r
�2 G-- 1A
z
N‘p: ,occbr4/2_ t :04 , I :::: eAcel,
P, a.-Ls 04--i_-. z.01`. As--104 '''' — / ,..,,,_
_VI _
t� I 1►
51 G"--• '''• . SS 21V2.1k, a�� [ZZ CA (1) � '�,
'. t.c1(71 i_ S v► Gc_ Six tete 4-----
•
S 9 aS,�f 2114 = ,gq �i
L. .5 , . 0SS 2.1.11 Sgt-o1Z( ) t• I�
13401 3 ,�, L
7--, o l (3,5-) 411.sSlf.k�
r`; 9 ,( t i ---
a •csi ( 3-s� -6 ' 1. 7
'- 1'3s-3s-6-1-) - 3 Z
S, ts
o,'1
ig '- 5.1 ,• lc y Z ,b 14
ffINI. Pe- a vt (7) '.
Z4 4
9320 SW BARBUR BLVD. SUITE 135 • PORTLAND, OR • 97219
PHONE: 503.892.5782 • EMAIL: DAVE@HORNCE.COM
MORN PROJECT 545/ 11- 1'1, SHEET Sir'I
IFIC CONSULTINGDATE 16 11.111
ENGINEERS LLC SUBJECT 'KQ• /2441T BY Ah
444;44; 1/140
AO /V0 Per (411-3- Psi' •
fi•Ifire'w• 6 d fF A�
�( ;'.o fT l.�
vg LIMO 'Kt
La 6.s Yr SPA" siatz C •C
• pc/ 1-.040Ly% 0.11 !
sr
F. 6. I i����i;- O 34
.k,
• o.tO4(43) '� d
e4 17 1.0
gj.
ac6s) t .
vw
osw,4 , 1.
r4 • . {. 4' '•
5P43;12° u 'V(e).SS''
•
Hf #Z
•
1302 SW BERTHA BLVD. • PORTLAND, OR • 97219
PunUR• Sill.R92.5782 • F.MA1H.: DAVP.(EHORNCE.COM
/.....IC HORN PROJECT XIII a ino rt. SHEET IS 4*-Z
CONSULTING ' p
A 11 • Mh'. DATE "r 11•`11
E ENGINEERS LLC SUBJECT ` (' By •1165%‘
GHPJoa Ti---R $t-N
I�� DL
bw, . o (g•s%� = �. .� G k
.3
3 •L or
•k
° a .3q ( 1-• 4 3'b
3• k
VAI . 1 ( 7 ' -t ----- • . e g,&.. i t te
a 4 .l. ,
"�,Lk (1�N _ v4 Z In
SPIAlas- 1,0 C' i 40
• L
dd ,fs�
k y l,S 4°'`f, s,S k 3° *► IV-
rrd►t N 4.3:- (2 . Si'�} %N. .J.JI4 S wer
4
•
11,
. s, I.
•
,
1302 SW BERTHA BLVD. • PORTLAND, OR • 97219
'••% CA, 0fl I C•/97 TT,..,,• IlevFn{-I/1RNf F.('(1M
PROJECT Ste'1'10'31 SHEET D' 1
/_\%1 HCE L DATE °1-/r''A1
f/
SUBJECT Ina- AMVAAA 1 ATVA1 TTxx
Horn Consulting Engineers LLC BY AU\
Z 1, 4.3 (x.) _ •' 3
ti1 L--12 W= ,a4fp��zj 1!. C_fs ,o
•, a .2.1, (1,2 4_, -- ).4.4.
A �.tc)
r% 0.1i 61.7-) 4 4.3 _ 4.301) ,_ 4 LI
I,a.(03k ? T. bk,c,
\/*-. 'i.s(t,k�
(..,..07t• (1.� = .-1s , _,
Zs, P
UQ 6,125 3' 44(\ 2 sir k •. PIVP/At n, s
1,(1,4 �4 sL.A.•
1r "; i r 6 L r a V 4
v -, .°0 c (*ii, 2c1 :. v,rtk ,4Ft
1
it-Pet'
ti 4
= 1.4 '� k Lt ' ?06k
DSI
43,61_
Z•R k
if 3i,
jArl- L'-dr,is Irv-,0 4E--"i, bk Y
f% Z‘4 t, ` \ , I,2-
21Lii, {f C.
/
2-4 (4) -1- ,ogtcl.E' 2
6,0()1-� Ws,
liCi
-,
t ( A)-. 04c (4 i_ - 6
1'. 6kt0
9320 SW BARBUR BLVD. SUITE 135 • PORTLAND, OR • 97219
PHONE: 503.892.5782 • EMAIL: DAVE@HORNCE.COM
PROJECT " -'' 141".11. SHEET 13!
HCE DATE 9,(5 /9
SUBJECT fod?/AA,N3 BY N
Horn Consulting Engineers LLC
S '4 waw
��. z• 4'-i' t 6 ,z61 -r2.cs 1.--) x127) ----
\--(3 ,1ki'S t"-A.Nr
2
P 11, 4 kl` - 2.S S �-� = 11-Sk
Htl z "
.s- L S M f l,d f --c 4 0 Jen:
\N-( , S le--1y
NI a f g1, 6,154. f 1k,tk * Z.c (Z� ^ 2'3,5
c,54 r I c Db. 4S ! /4 xn'S 4•.1 t11
w�q-444'S EA 'jA
c t
fii
V 3 4`r IrtAy
0/t' (1440%2- p, 5 4-g \Z�L = i a,s n
1 ) /-435?- ;41. k rtt Grp
'V44.44
v•-/ 10 .S t + • 3 = 1 4 ;e=.(,5 - q.9 wiz
9320 SW BARBUR BLVD. SUITE 135 • PORTLAND, OR • 97219
PHONE: 503.892.5782 • EMAIL: DAVE@HORNCE.COM
Rw i
Use menu item Settings>Printing&Title Block Title Lennar prototype wall Page: 1
to set these five lines of information Job#: Dsgnr: DJH Date: 16 FEB 2017
for your program. Description....
wall w/o slab for sliding
This Wall in File:c:\users\dave\documents\retainpro 10 project files\scouters lot 29 wall_Iennar.RP
RetainPro(c)1987.2017, Build 11.17.11.03
License:KW-06056184 Cantilevered Retaining Wall Code: IBC 2009,ACI 318-08,ACI 530-08
License To:HORN CONSULTING ENGINEERS
Criteria I Soil Data U -
Retained Height = 5.00 ft Allow Soil Bearing = 2,000.0 psf
Wall height above soil = 0.00 ft Equivalent Fluid Pressure Method
Active Heel Pressure = 50.0 psf/ft
Slope Behind Wall = 0.00
Height of Soil over Toe = 6.00 in =
Water height over heel = 0.0 ft Passive Pressure = 250.0 psf/ft
Soil Density, Heel = 125.00 pcf
Soil Density,Toe = 0.00 pcf
FootingIiSoil Friction = 0.450 -'
Soil height to ignore
for passive pressure = 12.00 in
Surcharge Loads ` LLateral Load Applied to Stem I Adjacent Footing Load
Surcharge Over Heel = 0.0 psf Lateral Load = 0.0#/ft Adjacent Footing Load = 0.0 lbs
Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft
Surcharge Over Toe = 0.0 ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in
Used for Sliding&Overturning Wall to Ftg CL Dist = 0.00 ft
Axial Load Applied to Stem Load Type = Wind ce(W0 inFooting Line Load
Base Above/Below Soil 0.0 ft
Axial Dead Load = 750.0 lbs Wind on Exposed Stem= 0.0 psf at Back of Wall
Axial Live Load = 750.0 lbs (Service Level) _
Axial Load Eccentricity = 0.0 in Poisson's Ratio 0.300
Earth Pressure Seismic Load
Method :MononobeOkabe/Seed-Whitman Kae for seismic earth pressure = 0.491 Added seismic base force 216.5 lbs
Design Kh = 0.200 g Ktin§�iee prsure = 0.353
= 0.137
Using Mononobe-Okabe/Seed-Whitman procedure
‘11,3 I.
Use menu item Settings>Printing&Title Block Title Lennar prototype wall Page: 2
to set these five lines of information Job#: Dsgnr: DJH Date: 16 FEB 2017
for your program. Description....
wall w/o slab for sliding
This Wall in File:c:\users\dave\documents\retainpro 10 project files\scouters lot 29 wall Iennar.RP
RetainPro(c)1987-2017, Build 11.17.11.03
License:KW-06056184 Cantilevered Retaining Wall Code: IBC 2009,ACI 318-08,ACI 530-08
License To:HORN CONSULTING ENGINEERS
Design Summary I Stem Construction I Bottom
Stem OK
Wall Stability Ratios Design Height Above Ftc ft= 0.00
Overturning = 3.02 OK Wall Material Above"Ht" = Concrete
Sliding = 1.55 OK Design Method = LRFD ASD LRFD
Thickness = 8.00
Total Bearing Load = 4,252 lbs Rebar Size = # 4
...resultant ecc. = 7.95 in Rebar Spacing = 13.00
Soil Pressure @ Toe = 1,936 psf OK Rebar laced at = Edge
D
Soil Pressure @ Heel = 65 psf OK Design Data
fb/FB+fa/Fa = 0.502
Allowable = 2,000 psf Total Force @ Section
Soil Pressure Less Than Allowable Service Level lbs=
ACI Factored @ Toe = 2,711 psf
ACI Factored @ Heel = 91 psf Strength Level lbs= 1,283.5
Moment....Actual
Footing Shear @ Toe = 5.7 psi OK Service Level ft#_
Footing Shear @ Heel = 0.9 psi OK Strength Level ft-#= 2,517.2
Allowable = 75.0 psi
Sliding Calcs Moment Allowable = 5,011.3
Lateral Sliding Force = 1,116.5 lbs Shear Actual
less 100%Passive Force= - 156.3 lbs Service Level psi=
less 100%Friction Force = - 1,575.9 lbs Strength Level psi= 17.1
Added Force Req'd = 0.0 lbs OK Shear Allowable psi= 75.0
....for 1.5 Stability = 0.0 lbs OK Anet(Masonry) in2= 139.50
Rebar Depth 'd' in= 6.25
Masonry Data
fm psi=
Fs psi=
Solid Grouting =
Vertical component of active lateral soil pressure IS Modular Ration' =
NOT considered in the calculation of soil bearing Wall Weight psf= 100.0
Load Factors Short Term Factor =
Building Code IBC 2009,ACI Equiv.Solid Thick. =
Dead Load 1.200 Masonry Block Type = Medium Weight
Live Load 1.600 Masonry Design Method = ASD
Earth, H 1.600 Concrete Data
Wind,W 1.000 fc psi= 2,500.0
Seismic,E 1.000 Fy psi= 60,000.0
Rw�
Use menu item Settings>Printing&Title Block Title Lennar prototype wall Page: 3
to set these five lines of information Job#: Dsgnr: DJH Date: 16 FEB 2017
for your program. Description....
wall w/o slab for sliding
This Wall in File:c:\users\dave\documents\retainpro 10 project files\scouters lot 29 wall_lennar.RP
RetainPro(c)1987-2017, Build 11.17.11.03
License:KW-06056184 Cantilevered Retaining Wall Code: IBC 2009,ACI 318-08,ACI 530-08
License To: HORN CONSULTING ENGINEERS
Concrete Stem Rebar Area Details
Bottom Stem Vertical Reinforcing Horizontal Reinforcing
As(based on applied moment): 0.0943 in2/ft
(4/3)*As: 0.1257 in2/ft Min Stem T&S Reinf Area 0.960 in2
200bd/fy:200(12)(6.25)/60000: 0.25 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.192 in2/ft
0.0018bh:0.0018(12)(8): 0.1728 in2/ft Horizontal Reinforcing Options
One layer of: Two layers of:
Required Area: 0.1728 in2/ft #4@ 12.50 in #4@ 25.00 in
Provided Area: 0.1846 in2/ft #5@ 19.38 in #5@ 38.75 in
Maximum Area: 0.8467 in2/ft #6@ 27.50 in #6@ 55.00 in
Footing Dimensions &Strengths I Footing Design Results
Toe Width = 1.00 ft Toe Heel
Heel Width = 3.25 Factored Pressure = 2,711 91 psf
Total Footing Width = 4.25 Mu':Upward = 1,253 2,074 ft-#
Footing Thickness = 12.00 in Mu':Downward = 128 3,103 ft-#
Mu: Design = 1,125 1,030 ft-#
Key Width = 0.00 in Actual 1-Way Shear = 5.69 0.93 psi
Key Depth = 0.00 in Allow 1-Way Shear = 40.00 40.00 psi
Key Distance from Toe = 0.00 ft Toe Reinforcing = None Spec'd
fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd
Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd
Min.As% = 0.0018 Other Acceptable Sizes&Spacings
Cover @ Top 2.00 @ Btm= 3.00 in
Toe: Not req'd:Mu<phi*5*lambda*sgrt(fc)*Sm
Heel:Not req'd:Mu<phi*5*lambda*sgrt(fc)*Sm
Key: No key defined
Min footing T&S reinf Area 1.10 in2
Min footing T&S reinf Area per foot 0.26 in2 fit
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 9.26 in #4@ 18.52 in
#5@ 14.35 in #5@ 28.70 in
#6@ 20.37 in #6@ 40.74 in
Summary of Overturning & Resisting Forces& Moments I
OVERTURNING RESISTING
Force Distance Moment Force Distance Moment
Item lbs ft ft-# lbs ft ft-#
Heel Active Pressure = 900.0 2.00 1,800.0 Soil Over Heel = 1,614.6 2.96 4,776.5
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load = Axial Dead Load on Stem= 750.0 1.33 1,000.0
Load @ Stem Above Soil= *Axial Live Load on Stem = 750.0 1.33 1,000.0
Seismic Earth Load = 216.5 3.60 779.4 Soil Over Toe = 0.50
= Surcharge Over Toe =
Total 1,116.5 O.T.M. 2,579.4 Stem Weight(s) = 500.0 1.33 666.7
Earth @ Stem Transitions=
_ = Footing Weight = 637.5 2.13 1,354.7
Resisting/Overturning Ratio = 3.02 Key Weight =
Vertical Loads used for Soil Pressure= 4,252.1 lbs Vert.Component =
Total= 3,502.1 lbs R.M.= 7,797.8
If seismic is included,the OTM and sliding ratios *Axial live load NOT included in total displayed,or used for overturning
be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201 resistance,but is included for soil pressure calculation.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Overturning Resistance.
( 1^)Li
Use menu item Settings>Printing&Title Block Title Scouter HS 29 Page: 1
to set these five lines of information Job#: Dsgnr: DJH Date: 11 SEP 2019
for your program. Description....
wall w/o slab for sliding
This Wall in File:c:\users\dave\documents\retainpro 10 project files\scouters lot 29 wall_lennar.RP
RetainPro(c)1987-2017, Build 11.17.11.03
License:KW-06056184 Cantilevered Retaining Wall Code: IBC 2009,ACI 318-08,ACI 530-08
License To: HORN CONSULTING ENGINEERS
Criteria I Soil Data
Retained Height = 6.00 ft Allow Soil Bearing = 2,000.0 psf
Wall height above soil = 0.00 ft Equivalent Fluid Pressure Method
Active Heel Pressure = 50.0 psf/ft
Slope Behind Wall = 0.00
Height of Soil over Toe = 6.00 in =
Water height over heel = 0.0 ft Passive Pressure = 250.0 psf/ft
Soil Density, Heel = 125.00 pcf
Soil Density,Toe = 0.00 pcf
FootingllSoil Friction = 0.450
Soil height to ignore
for passive pressure = 12.00 in
Surcharge Loads i Lateral Load Applied to Stem I Adjacent Footing Load
Surcharge Over Heel = 0.0 psf Lateral Load = 0.0#/ft Adjacent Footing Load = 0.0 lbs
Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft
Surcharge Over Toe = 0.0 ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in
Used for Sliding&Overturning Load Type = Wind(W) Wall
t
all to Ftg CL Dist = 0.00 ftAxial Load Applied to Stem (Service Level) Footing Type Line Load
Base Above/Below Soil 0.0 ft
Axial Dead Load = 750.0 lbs Wind on Exposed Stem= 0.0 psf at Back of Wall
Axial Live Load = 750.0 lbs (Service Level) Poisson's Ratio = 0.300
Axial Load Eccentricity = 0.0 in
Earth Pressure Seismic Load i
Method :Mononobe-Okabe/Seed-Whitman Kae for seismic earth pressure = 0.491 Added seismic base force 294.7 lbs
Design Kh = 0.200 9 Kgs§Uaprure = 0.353
= 0.137
Using Mononobe-Okabe/Seed-Whitman procedure
c&t3S
Use menu item Settings>Printing&Title Block Title Scouter HS 29 Page: 2
to set these five lines of information Job#: Dsgnr: DJH Date: 11 SEP 2019
for your program. Description....
wall w/o slab for sliding
This Wall in File:c:\users\dave\documents\retainpro 10 project files\scouters lot 29 wall_lennar.RP
RetainPro(c)1987-2017, Build 11.17.11.03
License:KW-06056184 Cantilevered Retaining Wall Code: IBC 2009,ACI 318-08,ACI 530-08
License To:HORN CONSULTING ENGINEERS
Design Summary I _Stem Construction I Bottom
Stem OK
Wall Stability Ratios Design Height Above Ftc ft= 0.00
Overturning = 3.51 OK Wall Material Above"Ht" = Concrete
Sliding = 1.54 OK Design Method = LRFD ASD LRFD
Thickness = 8.00
Total Bearing Load = 5,613 lbs Rebar Size = # 4
...resultant ecc. = 8.49 in Rebar Spacing = 11.00
Soil Pressure @ Toe = 1,808 psf OK Rebar Placed at = Edge
Design Data
Soil Pressure @ Heel = 233 psf OK fb
Allowable = 2,000 psf /FB+fa/Fa = 0.729
Soil Pressure Less Than Allowable Total Force @Section
ACI Factored @ Toe = 2,531 psf Service Level lbs=
ACI Factored @ Heel = 326 psf Strength Level lbs= 1,831.7
Moment....Actual
Footing Shear @ Toe = 9.7 psi OK Service Level ft-#=
Footing Shear @ Heel = 1.1 psi OK Strength Level ft-#= 4,290.3
Allowable = 75.0 psi
Sliding Calcs Moment Allowable = 5,883.6
Lateral Sliding Force = 1,519.7 lbs Shear Actual
less 100%Passive Force= - 156.3 lbs Service Level psi=
less 100%Friction Force = - 2,188.1 lbs Strength Level psi= 24.4
Added Force Req'd = 0.0 lbs OK Shear Allowable psi= 75.0
....for 1.5 Stability = 0.0 lbs OK Anet(Masonry) in2= 139.50
Rebar Depth 'd' in= 6.25
Masonry Data
fm psi=
Fs psi=
Solid Grouting =
Vertical component of active lateral soil pressure IS Modular Ration' =
NOT considered in the calculation of soil bearing Wall Weight psf= 100.0
Load Factors Short Term Factor =
Building Code IBC 2009,ACI Equiv.Solid Thick. =
Dead Load 1.200 Masonry Block Type = Medium Weight
Live Load 1.600 Masonry Design Method = ASD
Earth, H 1.600 Concrete Data
Wind,W 1.000 fc psi= 2,500.0
Seismic, E 1.000 Fy psi= 60,000.0
2w (:.
Use menu item Settings>Printing&Title Block Title Scouter HS 29 Page: 3
to set these five lines of information Job#: Dsgnr: DJH Date: 11 SEP 2019
for your program. Description....
wall w/o slab for sliding
This Wall in File:c:\users\dave\documents\retainpro 10 project files\scouters lot 29 wall_Iennar.RP
RetainPro(c)1987.2017, Build 11.17.11.03
License:KW-06056184 Cantilevered Retaining Wall Code: IBC 2009,ACI 318-08,ACI 530-08
License To:HORN CONSULTING ENGINEERS
Concrete Stem Rebar Area Details
Bottom Stem Vertical Reinforcing Horizontal Reinforcing
As(based on applied moment): 0.1607 in2/ft
(4/3)*As: 0.2143 in2/ft Min Stem T&S Reinf Area 1.152 in2
200bd/fy:200(12)(6.25)/60000: 0.25 in2/ft Min Stem T&S Reinf Area per ft of stem Height:0.192 in2/ft
0.0018bh:0.0018(12)(8): 0.1728 in2/ft Horizontal Reinforcing Options:
One layer of: Two layers of:
Required Area: 0.2143 in2/ft #4@ 12.50 in #4@ 25.00 in
Provided Area: 0.2182 in2/ft #5@ 19.38 in #5@ 38.75 in
Maximum Area: 0.8467 in2/ft #6@ 27.50 in #6@ 55.00 in
Footing Dimensions&Strengths Il Footing Design Results
Toe Width = 1.25 ft Toe Heel
Heel Width = 4.25 Factored Pressure = 2,531 326 psf
Total Footing Width = 5.50 Mu':Upward = 1,847 5,168 ft-#
Footing Thickness = 12.00 in Mu':Downward = 199 6,934 ft-#
Mu: Design = 1,648 1,766 ft-#
Key Width = 0.00 in Actual 1-Way Shear = 9.67 1.06 psi
Key Depth = 0.00 in Allow 1-Way Shear = 40.00 40.00 psi
Key Distance from Toe = 0.00 ft Toe Reinforcing = None Spec'd
ft = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd
Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd
Min.As% = 0.0018 Other Acceptable Sizes&Spacings
Cover @ Top 2.00 @ Btm.= 3.00 in
Toe: Not req'd: Mu<phi*5*lambda*sgrt(fc)*Sm
Heel: Not req'd: Mu<phi*5*lambda*sgrt(fc)*Sm
Key: No key defined
Min footing T&S reinf Area 1.43 in2
Min footing T&S reinf Area per foot 0.26 in2 /ft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 9.26 in #4@ 18.52 in
#5@ 14.35 in #5@ 28.70 in
#6@ 20.37 in #6@ 40.74 in
Summary of Overturning & Resisting Forces& Moments U
OVERTURNING RESISTING
Force Distance Moment Force Distance Moment
Item lbs ft ft-# lbs ft ft-#
Heel Active Pressure = 1,225.0 2.33 2,858.3 Soil Over Heel = 2,687.5 3.71 9,966.1
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load = Axial Dead Load on Stem= 750.0 1.58 1,187.5
Load @ Stem Above Soil= *Axial Live Load on Stem = 750.0 1.58 1,187.5
Seismic Earth Load = 294.7 4.20 1,237.6 Soil Over Toe = 0.63
= Surcharge Over Toe =
Total 1,519.7 O.T.M. 4,095.9 Stem Weight(s) = 600.0 1.58 950.0
Earth @ Stem Transitions=
= = Footing Weight = 825.0 2.75 2,268.8
Resisting/Overturning Ratio = 3.51 Key Weight =
Vertical Loads used for Soil Pressure= 5,612.5 lbs Vert.Component =
Total= 4,862.5 lbs R.M.= 14,372.4
If seismic is included,the OTM and sliding ratios *Axial live load NOT included in total displayed or used for overturning
be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201 resistance, but is included for soil pressure calculation.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Overturning Resistance.
c7
Use menu item Settings>Printing&Title Block Title Scouter HS 29 Page: 1
to set these five lines of information Job#: Dsgnr: DJH Date: 11 SEP 2019
for your program. Description....
wall w/o slab for sliding
This Wall in File:c:\users\dave\documents\retainpro 10 project files\scouters lot 29 wall_Iennar.RP
RetainPro(c)1987-2017, Build 11.17.11.03
License:KW-06056184 Cantilevered Retaining Wall Code: IBC 2009,ACI 318-08,ACI 530-08
License To:HORN CONSULTING ENGINEERS
Criteria I Soil Data
Retained Height = 7.00 ft Allow Soil Bearing = 2,000.0 psf
Wall height above soil = 0.00 ft Equivalent Fluid Pressure Method
Active Heel Pressure = 50.0 psf/ft
Slope Behind Wall = 0.00
Height of Soil over Toe = 6.00 in =
Water height over heel = 0.0 ft Passive Pressure = 250.0 psf/ft
Soil Density, Heel = 125.00 pcf ',,.
Soil Density,Toe = 0.00 pcf
FootingilSoil Friction = 0.450
Soil height to ignore iiiiiiiiiiiiiNi
for passive pressure = 12.00 in ! or
Surcharge Loads I Lateral Load Applied to Stem I Adjacent Footing Load111
Surcharge Over Heel = 0.0 psf Lateral Load = 0.0#/ft Adjacent Footing Load = 0.0 lbs
Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft
Surcharge Over Toe = 0.0 ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in
Used for Sliding&Overturning Wall to Ftg CL Dist = 0.00 ft
Load Type = Wind(W)
Axial Load Applied to StemFooting Type Line Load
(Service Level) Base Above/Below Soil
Axial Dead Load = 750.0 lbs Wind on Exposed Stem= 0.0 psf at Back of Wall = 0.0 ft
Axial Live Load = 750.0 lbs (Service Level) _
Axial Load Eccentricity = 0.0 in Poisson's Ratio 0.300
Earth Pressure Seismic Load
Method :Mononobe-Okabe/Seed-Whitman Kae for seismic earth pressure = 0.491 Added seismic base force 384.9 lbs
Design Kh = 0.200 g K ti ? 06s%ure = 0.353
= 0.137
Using Mononobe-Okabe/Seed-Whitman procedure
R cc
Use menu item Settings>Printing&Title Block Title Scouter HS 29 Page: 2
to set these five lines of information Job#: Dsgnr: DJH Date: 11 SEP 2019
for your program. Description....
wall w/o slab for sliding
This Wall in File:c:\users\dave\documents\retainpro 10 project files\scouters lot 29 wall_Iennar.RP
RetainPro(c)1987-2017, Build 11.17.11.03
License:KW-06056184 Cantilevered Retaining Wall Code: IBC 2009,ACI 318-08,ACI 530-08
License To: HORN CONSULTING ENGINEERS
_Design Summary I Stem Construction 1 Bottom
Stem OK
Wall Stability Ratios Design Height Above Ftc ft= 0.00
Overturning = 3.65 OK Wall Material Above"Ht" = Concrete
Sliding = 1.54 OK Design Method = LRFD ASD LRFD
Thickness = 8.00
Total Bearing Load = 7,185 lbs Rebar Size = # 4
...resultant ecc. = 9.92 in Rebar Spacing = 9.00
Soil Pressure @ Toe = 1,949 psf OK Rebar Placed at = Edge
Design Data
Soil Pressure @ Heel = 262 psf OK =
2,000 psffb/FB+fa/Fa 0.947
Allowable = Total Force @ Section
Soil Pressure Less Than Allowable Service Level lbs=
ACI Factored @ Toe = 2,728 psf
ACI Factored @ Heel = 367 psf Strength Level lbs= 2,477.2
Moment....Actual
Footing Shear @ Toe = 10.6 psi OK Service Level ft#_
Footing Shear @ Heel = 1.2 psi OK Strength Level ft-#= 6,745.5
Allowable = 75.0 psi
Sliding Calcs Moment Allowable = 7,122.4
Lateral Sliding Force = 1,984.9 lbs Shear Actual
less 100%Passive Force= - 156.3 lbs Service Level psi=
less 100%Friction Force = - 2,895.9 lbs Strength Level psi= 33.0
Added Force Req'd = 0.0 lbs OK Shear Allowable psi= 75.0
....for 1.5 Stability = 0.0 lbs OK Anet(Masonry) in2= 139.50
Rebar Depth 'd' in= 6.25
Masonry Data
fm psi=
Fs psi=
Solid Grouting =
Vertical component of active lateral soil pressure IS Modular Ratio'n' =
NOT considered in the calculation of soil bearing Wall Weight psf= 100.0
Load Factors Short Term Factor =
Building Code IBC 2009,ACI Equiv. Solid Thick. =
Dead Load 1.200 Masonry Block Type = Medium Weight
Live Load 1.600 Masonry Design Method = ASD
Earth,H 1.600 Concrete Data
Wind,W 1.000 fc psi= 2,500.0
Seismic, E 1.000 Fy psi= 60,000.0
Use menu item Settings>Printing&Title Block Title Scouter HS 29 Page 3u 1
to set these five lines of information Job#: Dsgnr: DJH Date: 11 SEP 2019
for your program. Description....
wall w/o slab for sliding
This Wall in File:c:\users\dave\documents\retainpro 10 project files\scouters lot 29 wall_Iennar.RP
RetainPro(c)1987-2017, Build 11.17.11.03
License:KW-06056184 Cantilevered Retaining Wall Code: IBC 2009,ACI 318-08,ACI 530-08
License To: HORN CONSULTING ENGINEERS
Concrete Stem Rebar Area Details
Bottom Stem Vertical Reinforcing Horizontal Reinforcing
As(based on applied moment): 0.2527 in2/ft
(4/3)*As: 0.337 in2/ft Min Stem T&S Reinf Area 1.344 in2
200bd/fy:200(12)(6.25)/60000: 0.25 in2/ft Min Stem T&S Reinf Area per ft of stem Height:0.192 in2/ft
0.0018bh:0.0018(12)(8): 0.1728 in2/ft Horizontal Reinforcing Options:
One layer of: Two layers of:
Required Area: 0.2527 in2/ft #4@ 12.50 in #4@ 25.00 in
Provided Area : 0.2667 in2/ft #5@ 19.38 in #5@ 38.75 in
Maximum Area: 0.8467 in2/ft #6@ 27.50 in #6@ 55.00 in
Footing Dimensions&Strengths I Footing Design Results
Toe Width = 1.25 ft Toe Heel
Heel Width = 5.25 Factored Pressure = 2,728 367 psf
Total Footing Width = 6.50 Mu': Upward = 2,013 9,685 ft-#
Footing Thickness = 12.00 in Mu': Downward = 199 12,919 ft-#
Mu: Design = 1,814 3,234ft-#
Key Width = 0.00 in Actual 1-Way Shear = 10.61 1.22 psi
Key Depth = 0.00 in Allow 1-Way Shear = 40.00 75.00 psi
Key Distance from Toe = 0.00 ft Toe Reinforcing = None Spec'd
fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = #4 @ 9.26 in
Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd
Min.As% = 0.0018 Other Acceptable Sizes&Spacings
Cover @ Top 2.00 @ Btm.= 3.00 in Toe: Not req'd:Mu<phi*5*lambda*sgrt(fc)*Sm
Heel:#4@ 9.26 in,#5@ 14.35 in,#6@ 20.37 in,#7@ 27.78 in,#8@ 36.57 in,#9@ 46
Key: No key defined
Min footing T&S reinf Area 1.68 in2
Min footing T&S reinf Area per foot 0.26 in2 /ft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 9.26 in #4@ 18.52 in
#5@ 14.35 in #5@ 28.70 in
#6@ 20.37 in #6@ 40.74 in
Summary of Overturning & Resisting Forces& Moments
OVERTURNING RESISTING
- Force Distance Moment Force Distance Moment
Item lbs ft ft-# lbs ft ft-#
Heel Active Pressure = 1,600.0 2.67 4,266.7 Soil Over Heel = 4,010.4 4.21 16,877.2
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load = Axial Dead Load on Stem= 750.0 1.58 1,187.5
Load @ Stem Above Soil= *Axial Live Load on Stem = 750.0 1.58 1,187.5
Seismic Earth Load = 384.9 4.80 1,847.4 Soil Over Toe = 0.63
= Surcharge Over Toe =
Total 1,984.9 O.T.M. 6,114.1 Stem Weight(s) = 700.0 1.58 1,108.3
Earth @ Stem Transitions=
= = Footing Weight = 975.0 3.25 3,168.8
Resisting/Overturning Ratio = 3.65 Key Weight =
Vertical Loads used for Soil Pressure= 7,185.4 lbs Vert.Component =
Total= 6,435.4 lbs R.M.= 22,341.8
If seismic is included,the OTM and sliding ratios *Axial live load NOT included in total displayed,or used for overturning
be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201 resistance,but is included for soil pressure caculation.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Overturning Resistance.
RIlo
Use menu item Settings>Printing&Title Block Title Scouter HS 29 Page: 1
to set these five lines of information Job#: Dsgnr: DJH Date: 11 SEP 2019
for your program. Description....
wall w/o slab for sliding
This Wall in File:c:\users\dave\documents\retainpro 10 project files\scouters lot 29 wall_lennar.RP
RetainPro(c)1987-2017, Build 11.17.11.03
License:KW-06056184 Cantilevered Retaining Wall Code: IBC 2009,ACI 318-08,ACI 530-08
License To:HORN CONSULTING ENGINEERS
Criteria I Soil Data
Retained Height = 8.00 ft Allow Soil Bearing = 2,000.0 psf
Wall height above soil = 0.00 ft Equivalent Fluid Pressure Method
Active Heel Pressure = 50.0 psf/ft
Slope Behind Wall = 0.00
Height of Soil over Toe = 6.00 in =
Water height over heel = 0.0 ft Passive Pressure = 250.0 psf/ft
Soil Density, Heel = 125.00 pcf
Soil Density,Toe = 0.00 pcf
FootingliSoil Friction = 0.450
Soil height to ignore
for passive pressure = 12.00 in =--
Surcharge Loads 0 [Lateral Load Applied to Stem 0 Adjacent Footing Load
Surcharge Over Heel = 0.0 psf Lateral Load = 0.0#/ft Adjacent Footing Load = 0.0 lbs
Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft
Surcharge Over Toe = 0.0 ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in
Used for Sliding&Overturning Wall to Ftg CL Dist = 0.00 ft
ilI Load Type = Wind(W)
Axial Load Applied to Stem (Service Level) Footing Type Line Load
Base Above/Below Soil
= 0.0 ft
Axial Dead Load = 750.0 lbs Wind on Exposed Stem = 0.0 psf at Back of Wall
Axial Live Load = 750.0 lbs (Service Level) Poisson's Ratio = 0.300
Axial Load Eccentricity = 0.0 in
Earth Pressure Seismic Load
Method : Mononobe Okabe/Seed-Whitman Kae for seismic earth pressure = 0.491 Added seismic base force 487.1 lbs
Design Kh = 0.200 g KPASIP 8e prsure = 0.353
= 0.137
Using Mononobe-Okabe/Seed-Whitman procedure
cwt
Use menu item Settings>Printing&Title Block Title Scouter HS 29 Page: 2
to set these five lines of information Job#: Dsgnr: DJH Date: 11 SEP 2019
for your program. Description....
wall w/o slab for sliding
This Wall in File:c:\users\dave\documents\retainpro 10 project files\scouters lot 29 wall_Iennar.RP
RetainPro(c)1987-2017, Build 11.17.11.03
License:KW-06056184 Cantilevered Retaining Wall Code: IBC 2009,ACI 318-08,ACI 530-08
License To:HORN CONSULTING ENGINEERS
Design Summary I Stem Construction I Bottom
Stem OK
Wall Stability Ratios Design Height Above Ftc ft= 0.00
Overturning = 4.00 OK Wall Material Above"Ht" = Concrete
Sliding = 1.50 OK Design Method = LRFD ASD LRFD
Thickness = 8.00
Total Bearing Load = 8,796 lbs Rebar Size = # 4
...resultant ecc. = 8.71 in Rebar Spacing = 6.00
Soil Pressure @ Toe = 1,772 psf OK Rebar Placed at = Edge
Design Data
Soil Pressure @ Heel = 497 psf OK
fb/FB+fa/Fa =
— 0.961
Allowable = 2,000 psf Total Force @ Section
Soil Pressure Less Than Allowable Service Level lbs=
ACI Factored @ Toe = 2,481 psf
ACI Factored @ Heel = 696 psf Strength Level lbs= 3,219.8
Moment....Actual
Footing Shear @ Toe = 21.3 psi OK Service Level ft-it_
Footing Shear @ Heel = 3.2 psi OK Strength Level ft-#= 9,993.6
Allowable = 75.0 psi
Sliding Calcs Moment Allowable = 10,400.4
Lateral Sliding Force = 2,512.1 lbs Shear Actual
less 100%Passive Force= - 156.3 lbs Service Level psi=
less 100%Friction Force = - 3,620.6 lbs Strength Level psi= 42.9
Added Force Req'd = 0.0 lbs OK Shear Allowable psi= 75.0
....for 1.5 Stability = 0.0 lbs OK Anet(Masonry) in2= 139.50
Rebar Depth 'd' in= 6.25
Masonry Data
fm psi=
Fs psi=
Solid Grouting =
Vertical component of active lateral soil pressure IS Modular Ratio'n' =
NOT considered in the calculation of soil bearing Wall Weight psf= 100.0
Load Factors Short Term Factor =
Building Code IBC 2009,ACI Equiv. Solid Thick. =
Dead Load 1.200 Masonry Block Type = Medium Weight
Live Load 1.600 Masonry Design Method = ASD
Earth,H 1.600 Concrete Data
Wind,W 1.000 fc psi= 2,500.0
Seismic, E 1.000 Fy psi= 60,000.0
Rt)IZ
Use menu item Settings>Printing&Title Block Title Scouter HS 29 Page: 3
to set these five lines of information Job#: Dsgnr: DJH Date: 11 SEP 2019
for your program. Description....
wall w/o slab for sliding
This Wall in File:c:\users\dave\documents\retainpro 10 project files\scouters lot 29 wall_Iennar.RP
RetainPro(c)1987-2017, Build 11.17.11.03
License:KW-06056184 Cantilevered Retaining Wall Code: IBC 2009,ACI 318-08,ACI 530-08
License To:HORN CONSULTING ENGINEERS
Concrete Stem Rebar Area Details
Bottom Stem Vertical Reinforcing Horizontal Reinforcing
As(based on applied moment): 0.3744 in2/ft
(4/3)*As: 0.4992 in2/ft Min Stem T&S Reinf Area 1.536 in2
200bd/fy:200(12)(6.25)/60000: 0.25 in2/ft Min Stem T&S Reinf Area per ft of stem Height:0.192 in2/ft
0.0018bh:0.0018(12)(8): 0.1728 in2/ft Horizontal Reinforcing Options:
One layer of: Two layers of:
Required Area: 0.3744 in2/ft #4@ 12.50 in #4@ 25.00 in
Provided Area: 0.4 in2/ft #5@ 19.38 in #5@ 38.75 in
Maximum Area: 0.8467 in2/ft #6@ 27.50 in #6@ 55.00 in
Footing Dimensions&Strengths I Footing Design Results
Toe Width = 1.75 ft Toe Heel
Heel Width = 6.00 Factored Pressure = 2,481 696 psf
Total Footing Width = 7.75 Mu':Upward = 3,594 15,728 ft-#
Footing Thickness = 12.00 in Mu':Downward = 390 19,627 ft-#
Mu: Design = 3,204 3,899 ft-#
Key Width = 0.00 in Actual 1-Way Shear = 21.26 3.25 psi
Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi
Key Distance from Toe = 0.00 ft Toe Reinforcing = #4 @ 6.00 in
fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = #4 @ 9.26 in
Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd
Min.As% = 0.0018 Other Acceptable Sizes&Spacings
Cover @ Top 2.00 @ Btm.= 3.00 in
Toe: #4@ 9.26 in,#5@ 14.35 in,#6@ 20.37 in,#7@ 27.78 in,#8@ 36.57 in,#9@ 46
Heel:#4@ 9.26 in,#5@ 14.35 in,#6@ 20.37 in,#7@ 27.78 in,#8@ 36.57 in,#9@ 46
Key: No key defined
Min footing T&S reinf Area 2.01 in2
Min footing T&S reinf Area per foot 0.26 in2 /ft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 9.26 in #4@ 18.52 in
#5@ 14.35 in #5@ 28.70 in
#6@ 20.37 in #6@ 40.74 in
Summary of Overturning & Resisting Forces & Moments
OVERTURNING RESISTING
Force Distance Moment Force Distance Moment
Item lbs ft ft-# lbs ft ft-#
Heel Active Pressure = 2,025.0 3.00 6,075.0 Soil Over Heel = 5,333.3 5.08 27,111.1
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load = Axial Dead Load on Stem= 750.0 2.08 1,562.5
Load @ Stem Above Soil= *Axial Live Load on Stem = 750.0 2.08 1,562.5
Seismic Earth Load = 487.1 5.40 2,630.4 Soil Over Toe = 0.88
= Surcharge Over Toe =
Total 2,512.1 O.T.M. 8,705.4 Stem Weight(s) = 800.0 2.08 1,666.7
Earth @ Stem Transitions=
= = Footing Weight = 1,162.5 3.88 4,504.7
Resisting/Overturning Ratio = 4.00 Key Weight =
Vertical Loads used for Soil Pressure= 8,795.8 lbs Vert.Component =
Total= 8,045.8 lbs R.M.= 34,845.0
If seismic is included,the OTM and sliding ratios *Axial live load NOT included in total displayed or used for overturning
be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201 resistance,but is included for soil pressure calculation.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Overturning Resistance.
SZkIs 13
Use menu item Settings>Printing&Title Block Title Scouter HS 29 Page: 1
to set these five lines of information Job#: Dsgnr: DJH Date: 11 SEP 2019
for your program. Description....
wall w/o slab for sliding
This Wall in File:c:\users\dave\documents\retainpro 10 project files\scouters lot 29 wall_lennar.RP
RetainPro(c)1987-2017, Build 11.17.11.03
License:KW-06056184 Cantilevered Retaining Wall Code: IBC 2009,ACI 318-08,ACI 530-08
License To: HORN CONSULTING ENGINEERS
Criteria I Soil Data
Retained Height = 9.00 ft Allow Soil Bearing = 2,000.0 psf
Wall height above soil = 0.00 ft Equivalent Fluid Pressure Method
Active Heel Pressure = 50.0 psf/ft
Slope Behind Wall = 0.00
Height of Soil over Toe = 6.00 in =
Water height over heel = 0.0 ft Passive Pressure = 250.0 psf/ft
Soil Density, Heel = 125.00 pcf
Soil Density,Toe = 0.00 pcf
FootingilSoil Friction = 0.450
Soil height to ignore
for passive pressure = 12.00 in .
Surcharge Loads 1 Lateral Load Applied to Stem ` Adjacent Footing Load
Surcharge Over Heel = 0.0 psf Lateral Load = 0.0#/ft Adjacent Footing Load = 0.0 lbs
Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft
Surcharge Over Toe = 0.0 ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in
Used for Sliding&Overturning Wall to Ftg CL Dist = 0.00 ft
Load Type = Wind(W)
Axial Load Applied to Stem Footing Type Line Load
(Service Level) Base Above/Below Soil
Axial Dead Load = 750.0 lbs Wind on Exposed Stem= 0.0 psf at Back of Wall = 0.0 ft
Axial Live Load = 750.0 lbs (Service Level) Poisson's Ratio = 0.300
Axial Load Eccentricity = 0.0 in
Earth Pressure Seismic Load
Method :Mononobe-Okabe/Seed-Whitman Kae for seismic earth pressure = 0.491 Added seismic base force 621.6 lbs
Design Kh = 0.200 g KASIP eeprl ure = 0.353
= 0.137
Using Mononobe-Okabe/Seed-Whitman procedure
CSW t
Use menu item Settings>Printing&Title Block Title Scouter HS 29 Page: 2
to set these five lines of information Job#: Dsgnr: DJH Date: 11 SEP 2019
for your program. Description....
wall w/o slab for sliding
This Wall in File:c:\users\dave\documents\retainpro 10 project files\scouters lot 29 wall_Iennar.RP
RetainPro(c)1987-2017, Build 11.17.11.03
License:KW-06056184 Cantilevered Retaining Wall Code: IBC 2009,ACI 318-08,ACI 530-08
License To:HORN CONSULTING ENGINEERS
Design Summary i _Stem Construction i Bottom
Stem OK
Wall Stability Ratios Design Height Above Ftc ft= 0.00
Overturning = 4.20 OK Wall Material Above"Ht" = Concrete
Sliding = 1.53 OK Design Method = LRFD ASD LRFD
Thickness = 10.00
Total Bearing Load = 11,138 lbs Rebar Size = # 5
...resultant ecc. = 8.82 in Rebar Spacing = 9.00
Soil Pressure @ Toe = 1,844 psf OK Rebar Placed at = Edge
Design Data
Soil Pressure @ Heel = 631 psf OK
fb/FB+fa/Fa = 0.995
Allowable = 2,000 psf Total Force @ Section
Soil Pressure Less Than Allowable
ACI Factored @ Toe = 2,582 psf Service Level lbs=
ACI Factored @ Heel = 883 psf Strength Level lbs= 4,080.2
Footing Shear @ Toe = 19.3 psi OK Moment....Actual
Service Level ft-#=
Footing Shear @ Heel = 4.2 psi OK Strength Level ft-#= 14,257.0
Allowable = 75.0 psi
Sliding Calcs Moment Allowable = 14,321.6
Lateral Sliding Force = 3,205.6 lbs Shear Actual
less 100%Passive Force= - 222.2 lbs Service Level psi=
less 100%Friction Force = - 4,674.4 lbs Strength Level psi= 41.5
Added Force Req'd = 0.0 lbs OK Shear Allowable psi= 75.0
....for 1.5 Stability = 0.0 lbs OK Anet(Masonry) in2= 139.50
Rebar Depth 'd' in= 8.19
Masonry Data
fm psi
Fs psi=
Solid Grouting =
Vertical component of active lateral soil pressure IS Modular Ration' =
NOT considered in the calculation of soil bearing Wall Weight psf= 125.0
Load Factors Short Term Factor =
Building Code IBC 2009,ACI Equiv.Solid Thick. =
Dead Load 1.200 Masonry Block Type = Medium Weight
Live Load 1.600 Masonry Design Method = ASD
Earth,H 1.600 Concrete Data
Wind,W 1.000 fc psi= 2,500.0
Seismic,E 1.000 Fy psi= 60,000.0
RI) tS
Use menu item Settings>Printing&Title Block Title Scouter HS 29 Page: 3
to set these five lines of information Job#: Dsgnr: DJH Date: 11 SEP 2019
for your program. Description....
wall w/o slab for sliding
This Wall in File:c:\users\dave\documents\retainpro 10 project files\scouters lot 29 wall_Iennar.RP
RetainPro(c)1987-2017, Build 11.17.11.03
License:KW-06056184 Cantilevered Retaining Wall Code: IBC 2009,ACI 318-08,ACI 530-08
License To:HORN CONSULTING ENGINEERS
Concrete Stem Rebar Area Details
Bottom Stem Vertical Reinforcing Horizontal Reinforcing
As(based on applied moment): 0.4026 in2/ft
(4/3)*As: 0.5368 in2/ft Min Stem T&S Reinf Area 2.160 in2
200bd/fy:200(12)(8.1875)/60000: 0.3275 in2/ft Min Stem T&S Reinf Area per ft of stem Height:0.240 in2/ft
0.0018bh :0.0018(12)(10): 0.216 in2/ft Horizontal Reinforcing Options:
One layer of: Two layers of:
Required Area: 0.4026 in2/ft #4@ 10.00 in #4@ 20.00 in
Provided Area: 0.4133 in2/ft #5@ 15.50 in #5@ 31.00 in
Maximum Area: 1.1092 in2/ft #6@ 22.00 in #6@ 44.00 in
Footing Dimensions &Strengths M Footing Design Results
Toe Width = 2.00 ft Toe Heel
Heel Width = 7.00 Factored Pressure = 2,582 883 psf
Total Footing Width = 9.00 Mu':Upward = 4,912 24,170 ft-#
Footing Thickness = 14.00 in Mu':Downward = 570 29,662 ft-#
Mu: Design = 4,342 5,492 ft-#
Key Width = 0.00 in Actual 1-Way Shear = 19.34 4.24 psi
Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi
Key Distance from Toe = 0.00 ft Toe Reinforcing = #5 @ 12.30 in
fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = #5 @ 12.30 in
Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd
Min.As% = 0.0018 Other Acceptable Sizes&Spacings
Cover @ Top 2.00 @ Btm.= 3.00 in
Toe: #4@ 7.94 in,#5@ 12.30 in,#6@ 17.46 in,#7@ 23.81 in,#8@ 31.35 in,#9@ 39
Heel:#4@ 7.94 in,#5@ 12.30 in,#6@ 17.46 in,#7@ 23.81 in,#8@ 31.35 in,#9@ 39
Key: No key defined
Min footing T&S reinf Area 2.72 in2
Min footing T&S reinf Area per foot 0.30 in2 /ft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 7.94 in #4@ 15.87 in
#5@ 12.30 in #5@ 24.60 in
#6@ 17.46 in #6@ 34.92 in
Summary of Overturning & Resisting Forces& Moments
OVERTURNING RESISTING
Force Distance Moment Force Distance Moment
Item lbs ft ft-# lbs ft ft-#
Heel Active Pressure = 2,584.0 3.39 8,757.0 Soil Over Heel = 6,937.5 5.92 41,046.9
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load = Axial Dead Load on Stem= 750.0 2.42 1,812.5
Load @ Stem Above Soil= *Axial Live Load on Stem = 750.0 2.42 1,812.5
Seismic Earth Load = 621.6 6.10 3,791.6 Soil Over Toe = 1.00
= Surcharge Over Toe =
Total 3,205.6 O.T.M. 12,548.6 Stem Weight(s) = 1,125.0 2.42 2,718.8
Earth @ Stem Transitions=
_ = Footing Weight = 1,575.0 4.50 7,087.5
Resisting/Overturning Ratio = 4.20 Key Weight =
Vertical Loads used for Soil Pressure= 11,137.5 lbs Vert.Component =
Total= 10,387.5 lbs R.M.= 52,665.6
If seismic is included,the OTM and sliding ratios *Axial live load NOT included in total displayed or used for overturning
be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201 resistance,but is included for soil pressure calculation.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Overturning Resistance.
EWP Studio Client: Date: 10/11/2019 Page 1 of 3
Simpson Strong Tie®
Component SolutionsTM Project: Input by: KAMI HENDERSON
Address: Job Name: CALCS
Project#:
J1 RFPI 400 11.875" - PASSED Level:UPPER Level
OFFICE COPY
2
4, 1
oo o /11 7/8„
1 D Fir 2 D.Fir 3 D.Fir
1' I 20'6" 6'6" 21/16"
28'
Member Information Reactions UNPATTERNED lb(Uplift)
Type: Joist Application: Floor Brg Live Dead Snow Wind Const
Spacing: 16"o.c. Design Method: ASD 1 510 296 53 0 0
Moisture Condition: Dry Building Code: IBC/IRC 2015 2 1117 319 0(-6) 0 0
Deflection LL: 480 Load Sharing: No 3 0(-134) (-33) 3 0 0
Deflection TL: 360 Deck: 3/4 APA Rated Sturd-l-
Importance: Normal FloorOSB Nailed and
Glued
Temperature: Temp<=100°F
General Load Ceiling: Gypsum 1/2" Bearings
Floor Live: 40 PSF Bearing Length Cap. React D/L lb Total Ld.Case Ld.Comb.
Dead: 12 PSF 1-D.Fir 5.500" 34% 295/512 807 LL_ D+L
2-D.Fir 5.500" 62% 321/1126 1447 _LL D+L
Analysis Results 3-D.Fir 2.750" 27% -34/170 136 L_L D+L
Analysis Actual Location Allowed Capacity Comb. Case (-334)
Neg Moment -2567 ft-lb 21'6" 4315 ft-lb 0.595(59%) D+L _LL
Pos Moment 2335 ft-lb 9'8 3/16" 4315 ft-lb 0.541(54%) D+L _L_
Shear 822 lb 21'6" 1480 lb 0.556(56%) D+L _LL
LL Defl inch 0.336(L/724) 10'6 5/8" 0.507(U480) 0.660(66%) L _L_
TL Defl inch 0.424(L/574) 107 1/8" 0.676(U360) 0.630(63%) D+L _L_
LL Cant -0.053 Lt Cant 0.200 0.265(26%) L _L_
(21/454) (21/480)
TL Cant -0.063 Lt Cant 0.300 0.209(21%) D+L _L_
(2L/384) (2L/360)
Design Notes
1 Tie-down connection required at bearing 3 for uplift 334 lb(Combination D+L,Load Case
U .
2 Cantilever Upward Deflection Live Load 0.052913 greater than recommended 0.05
ID Load Type Location Trib Width Dead 0.9 Live 1 Snow 1.15 Wind 1.6 Const.1.25 Comments
1 Uniform 1-4-0 12 PSF 40 PSF 0 PSF 0 PSF 0 PSF
2 Point 0-0-0 134 lb 0 lb 50 lb 0 lb 0 lb
•
Notes chemicals 5.Provide lateral support at bearing points to avoid Manufacturer Info PACIFIC LUMBER&TRUSS CO.
Calculated Structured Designs is responsible only of the Handling 8 Installation lateral displacement and rotation RoseburgForest Products 10515 SW ALLEN BLVD,OREGON
structural adequacy of this component based on the 6.Web stiffeners for point load as shown Minimum 97005
1.!Joist flanges must not be cut or drilled point load bearing lengtiv=3.5 inches 4500 Riddle By-pass Rd 503-858-9663
design criteria and loadings shown. It is the 2.Refer to latest copy of the!Joist product Information 7.For flat roofs provide proper drainage to prevent Riddle,OR 97469
responsibility of the customer and/or the contractor to details for framing details,stiffener tables,web hole ponding
ensure the component suitability of the intended chart,bridging details,multi-ply fastening details and (541)784 005
application,and to verify the dimensions and loads. handling/erection details www.roseburg.corn
Lumber 3.Damaged!Joists must not be used APA:PR-L259,ICC-ES:ESR-1251 Pacif umber
1.D diems,unless noted otherwise 4.Design assumes top flange to be laterally restrained
Dry service con by attached sheathing or as specified in engineering
2.!Joist not to be treated with fire retardant or corrosive 0"""v
notes. This design is valid until 1/7/2022 & TRU 5 5
EWP Studio Version 19.12.001 Powered by iStructr"
Strang,tr
Client: Date: 10/11/2019 Page 2 of 3
EWP Studio
Project: Input by: KAMI HENDERSON
E Simpson Strong-Tie 0
Address: Job Name: CALCS
Component SolutlonsTM
Project#:
J3 RFPI 400 11.875" - PASSED Level:UPPER Level
1
/
--.4;'' ' '' . '' ---'.1 , :"L", ,1.,,f, ,,. --n.'1; -,- ,' ,"'" 11 7/8"
In Cl /
1 D.Fir 2 D.Fir
172"
' " ...4/
2 1/16
172 "
Member Information Reactions UNPATTERNED lb(Uplift)
Type: Joist Application: Floor Brg Live Dead Snow Wind Const
Spacing: 16"o.c. Design Method: ASD 1 458 137 0 0 0
Moisture Condition: Dry Building Code: IBC/IRC 2015 2 458 137 0 0 0
Deflection LL: 480 Load Sharing: No
Deflection TL: 360 Deck: 3/4 APA Rated Sturd-l-
ImportanceNormal FloorOSB Nailed and
:
Glued
Temperature: Temp<=100°F
Ceiling: Gypsum 1/2"
General Load Bearings
Floor Live: 40 PSF Bearing Length Cap. React D/L lb Total Ld.Case Ld.Comb.
Dead: 12 PSF 1-D.Fir 2.000" 54% 137/458 595 L D+L
' 2-D.Fir 2.000" 54% 137/458 595 L D+L
Analysis Results
Analysis Actual Location Allowed Capacity Comb. Case
Moment 2492 ft-lb 87" 4315 ft-lb 0.578(58%) D+L L
Shear 588 lb 1 1/4" 1480 lb 0.397(40%) D+L L
LL Defl inch 0.276(U738) 87 1/16" 0.424(L/480) 0.650(65%) L L
TL Defl inch 0.359(L/568) 87 1/16" 0.565(L/360) 0.630(63%) D+L L
ID Load Type Location Trib Width Dead 0.9 Live 1 Snow 1.15 Wind 1.6 Const.1.25 Comments
1 Uniform 1-4-0 12 PSF 40 PSF 0 PSF 0 PSF 0 PSF
Notes chemicals 5.Provide lateral support at bearing points to avoid Manufacturer Info PACIFIC LUMBER&TRUSS CO.
lateral displacement and rotabon '
RoseburForest Products 10515 SWALLEN BLVD,OREGON
Calculated Structured Designs is responsible only of the Handling&Installation g 6.Web stiffeners for plant load as shown Minimum 97005
structural adequacy of this component based on the 1.!Joist flanges must not be cut or drilled point load bearing length>.3.5 inches 4500 Riddle By-pass Rd
design critena and loadings shown. It is the 2 Refer to latest copy of the IJoist product information 7.For 111M roMs provide proper drainage to prevent Riddle,OR 97469 503-858-9663
responsibility of the customer and/or the contractor to details for framing details,stiffener tables,web hole onding
ensure the component suitabdity of the intended chart,bndgtng details,mult-ply fastening details and p (541)7844005
application,and to venfy the dimensions and loads. handling/erecton details www.roseburg.corn
Lumber 3.Damaged!Joists must not be used APA:PR-L259,ICC-ES:ESR-1251 Pacifiatumber
4. sign assumes top flange to be laterally restrained
1.Dry service conditions,unless noted otherwise De
by attached sheathing or as specified m neenng
2.!Joist not to be treated with fire retardcorrosive ant or
notes. enmThis design is valid until 1/7/2022 & T R U S S
EWP Studio Version 19.12.001 Powered by iStructta =I
=71
EWP Studio Client: Date: 10/11/2019 Page 3 of 3
Project: Input by: KAMI HENDERSON
Simpson Strong-Tie®
Address: Job Name: CALCS
Component SolutionsTM
Project#:
J6 RFPI 70 11.875" - PASSED Level:UPPER Level
1
/
0' .. 0 /
1 D.Fir 2 D.Fir
20'1"
20'1" /-/2 5/16"
Member Information Reactions UNPATTERNED lb(Uplift)
Type: Joist Application: Floor Brg Live Dead Snow Wind Const
Spacing: 12"o.c. Design Method: ASD 1 402 121 0 0 0
Moisture Condition: Dry Building Code: IBC/IRC 2015 2 402 121 0 0 0
Deflection LL: 480 Load Sharing: No
Deflection TL: 360 Deck: 3/4 APA Rated Sturd-l-
Importance: Normal FloorOSB Nailed and
Glued
Temperature: Temp<=100°F
Ceiling: Gypsum 1/2"
General Load Bearings
Floor Live: 40 PSF Bearing Length Cap. React D/L lb Total Ld.Case Ld.Comb.
Dead: 12 PSF 1-D.Fir 2.000" 42% 121/402 522 L D+L
2-D.Fir 2.000" 42% 121/402 522 L D+L
Analysis Results
Analysis Actual Location Allowed Capacity Comb. Case
Moment 2568 ft-lb 10'1/2" 6645 ft-lb 0.386(39%) D+L L
Shear 517 lb 1 1/4" 1550 lb 0.333(33%) D+L L
LL Defl inch 0.301(L/792) 10'9/16" 0.497(0480) 0.610(61%) L L
TL Defl inch 0.392(L/609) 10'9/16" 0.662(L/360) 0.590(59%) D+L L
ID Load Type Location Trib Width Dead 0.9 Live 1 Snow 1.15 Wind 1.6 Const.1.25 Comments
1 Uniform 1-0-0 12 PSF 40 PSF 0 PSF 0 PSF 0 PSF
Notes chemicals 5.Provide lateral support at bearing points to avoid Manufacturer Info PACIFIC LUMBER&TRUSS CO.
Calculated Structured Designs is responsible only of the Handling&Installation lateralsdisplacementand rotations RoseburgForest Products 10515 SW ALLEN BLVD,OREGON
structural adequacyof this component based on the 6.Web liflenem for point load s shown Minimum 97005
omponen 1.IJoist flanges must not be cut or drilled point load bearing length>=3.5 inches 4500 Riddle By-pass Rd 503-858-9663
design criteria and loadings shown. It Is Me 2.Refer to latest copy of the!Joist product information 7.For flat roofs provide proper&meg°to prevent Riddle,OR 97469
responsibiley of the customer and/or the contractor to details for framing details,stiffener tables,web hole ponding
ensure the component suitability of the intended chart,bridging details,multi-ply fastening details and (541)784-4005
applicebon,and to verify the dimensions and loads. handinglerecton details www.roseburg.com
Lumber 3.Design a'Joists must aoge to used APA.PR-L259,ICC-ES:ESR-1251 Paci lumber
1.Dry service conditions,unless noted otherwise 4.Design assumes top flange ecbe laterally restrained
2.!Joist not to be treated with fire retardant or corrosive by attached sheathing or as specified in engineering & TRUSS \ c o mo eu e n
notes. This design is valid until 1/7/2022
EWP Studio Version 19.12.001 Powered by iStructme