Loading...
Plans RECEIVED Building Plans for City of Tigard Building Permit Application OCT 7 2019 Customer: The Fountains at Summerfield condominiums HOA CITY OF TIGARD 15685 SW 116th Ave., #105 BUILDING DIVISION Tigard, OR 97224 Contact - Paul Brock, 858-212-9105, pbrock987(E)email.com Contractor: Jon Erickson, 503-730-9220 ion.eveniobsPemail.com CCB 162397 OFFICE COPS' CITY OF TIGARD Scope of Work—Repair Decks REVIE D FOR CODE COMPLIANCE • Replace perimeter joists with PT • Repair joist and soffit dry rot Approved: I OTC: I • Replace 42" guardrail and infill to comply with Permit#: u �co ) 9 - n0 C IBC multi-family code Address: pc cf2 S j )9 C Suite#: By: - Date: 0_ ) File Name: Fountains Deck Permit Plans REVISED.pptx VALIDITY OF PER' 1 ; THE ISSUANCE OF A PEF;i,�:_' BASED ON CONSTRUCT'c,N DOCUMENTS AND OTH DATA SHALL NOT PR:P`,'"`' THE CODE OFFICIAL =P REQUIRING THE COR OF ERRORS. 0=',q,- 10/6/19 q10/6/19 Fountains at Summerfield - Deck Building Plans 1 Wood structural members that Irk exposed to the wdetother to be Pressure Treated or de y rg w,t per 317.1.3 Typical Deck Construction and Size — 102 SF Brick Col. 114.5" 15x11.5 —� Imbedded 6x6 PT A E. 4x4 PT Posts • g 2 x 8 PT blocking between joists attached with Three 16D 3-1/2"n HDG >< Ref: 2014 Oregon Structural 43" 15" 56.5 Specialty Code- -Table 2304.9.1-29 2"x8" Joists 16" OC lateral joists with / Blocking supports Simpson Rim joist attached to Tension Ties DTT2Z. Two DTT2Z brackets required for Three 16D 3-1/2"n HDG ----'� posts in this position. See Beam"' 6"x10" Simpson Wood Connection Ref: 2014 Oregon Connectors 2018-18 Deck Structural Specialty Lo Tension Ties—page 337 Code—Table ai 2304.9.1-29 House— Brick exterior 43" Scale— 12"/increment Y Lilo 10/6/19 Fountains at Summerfield - Deck Building Plans 2 Water Penetration Remediation — Cross Section Posts—4x4 PT Flashing 2" x 3" V- Resurfacing material 3/4" exterior plywood decking N_ 0 —,E 00 X N --JHardi-plank Fascia 9.25" x .25". Applied with exterior adhesive and secured with post bolts. Wicking protection for soffit provided by / extension. Pre-paint before adding flashing 77 %" plywood soffit Scale— 1" increment 10/6/19 Fountains at Summerfield - Deck Building Plans 3 • Guard Rail Post — Simpson Tension Ties Posts—4x4 PT Simpson DDT2Z Attach to lateral joist with 8 SDS 1 5" screws r %" x 6" Machine Bolt DTT2Z supports 1800 Ib. HDG with nuts and tension load. Meets IBC washers Code for multi-family deck 00 o guardrails. N E 4 Refer to attached Simpson °C catalog- Deck Tension Ties Lateral Joist page 337 ��` Also refer to Simpson code- compliant Guardrail Post Connection bulletin T-C-GRDRLPST17 Scale—1" increment 10/6/19 Fountains at Summerfield - Deck Building Plans 4 Typical Guardrail and Infill Section — 50// max. between posts Simpson Strong Drive A >..,.: ,, ,, , „���� �,m4P : '-'''''''''''''''':"-tk'�� .:' Wide Screw SDWS 4”, 2 3/8"TL. Two per I Railing 2 x 4 TKC het enri d, three in mid span Cap Rail —Trex a/. 1" x 5.5" attached to r� I I e 44 Puy; Railingwith �4 " F ES i ii i4 t;, exterior , a , ,14 0 I I adhesive. A1111111 � "' r ter d.. WO VX' 4 ViN 440 r Lrl 1 Railing Support Ftil ii p d 2x4TKC . a 4. 4 03 r t4''141' di ; a Attached to �- ,<v; i4 ¢y, , ; 10 I �, Railing and � � ,�� • ��, 4�ig �,�'._ ti n,` �, � ip Installation of x I " 3 §" t4 1' balasters and rails Posts with 40: ' It 0a41; �' Ao. k„ per mfg installation adhesive and r, * ' tos . • fs, h til S ' Simpson ;. t, .. instructions. • X Strong i<' r;. x.;; ,r„, Wide Screw SDWS 4", , Railing 2 x 4 TKC Railing Infill - 2 3/8"TL. I DecKorator aluminum V 2.75” space balaster%" x 32". Spacing 3.75" DecKorator Scale 1" increments 4 4 CodeCompliance Research Report iiiiiiiiiiiii CCRR-0161 10/6/19 Fountains at Summerfield - Deck Building Plans 5 of 5