Report (2) Ms`r2o19-cto Lai I 0q59swIof3Ift4AV intertek Code Compliance Research Report Total Quality.Assured. ECEIVE CCRR-0202 NDV 18 2019 Issue Date: 02-21-2014 CITY OF TIGARD Revision Date: 02-27-2019 BUILDING DIVISION Renewal Date:02-21-2020 DIVISION:05 00 00-METALS 2.0 STATEMENT OF COMPLIANCE Section:05 52 00—Metal Railings Trex° Signature° and Tref RevealTM Railing comply with the REPORT HOLDER: Codes listed in Section 1.1, for the properties stated in Trex Company,Inc. Section 1.2 and uses stated in Section 1.3, when installed as 160 Exeter Drive described in this report, including the Conditions of Use Winchester,VA 22603 stated in Section 6. (540)542-6300 www.Trex.com 3.0 DESCRIPTION REPORT SUBJECT: 3.1 The Trex° Signature' / Trex® Reveal'" Railing is an Trex°Signature°Railing assemblage of extruded aluminum materials,stainless steel Trex°Reveal"Railing fasteners,and cast Zamak 3 bracket materials. 1.0 SCOPE OF EVALUATION 3.2 The guardrail system includes a top rail, bottom rail, balusters, structural aluminum post, rail-to-post brackets, 1.1 This Research Report addresses compliance with the and decorative moldings and post caps. following Codes: 2015 and 2012 International Residential Code®(IRC) 3.3 Each of the top and bottom aluminum rails are routed to accept various infill components described in Section 1.2 Trex°Signature' and Trex' Reveal'" Railing have been 3.4. evaluated for the following properties(see Table 1): Structural Performance 3.3.1 The top rail is an extruded aluminum rail with internal longitudinal ribs, dimensions of 1.75 inches wide by 1.44 inches tall.See Figure 1.A PVC rail insert is 1.3 Trex'Signature'and Trex`Reveal"Railing have been used as a baluster retainer. evaluated for the following uses(see Table 2): The Trex®Reveal'railing system is a guard or guardrail 3.3.2 The bottom rail is an extruded aluminum rail with under the definitions of the referenced codes. It is internal longitudinal ribs, dimensions of 1.75 inches intended for use at or near the open sides of elevated wide by 1.25 inches tall.See Figure 2.A PVC rail insert is walking areas of buildings and walkways as required by used as a baluster retainer. the codes. Trex° Signature' Railing is an alternative name for Trex`Reveal'Railing. 3.4 The infill area utilizes aluminum square or round Guards are provided as level guards for level walking balusters(See Figure 3). areas such as decks,balconies,and porches. Levelguards are 3.5 Aluminum post supports consist of a 2.5 inch square by provided with rail lengths up to 96 0.125 inch wall extruded aluminum tube. The tube is inches in length (measured between the inside of connected to a 4 inch square by 1/2 inch thick aluminum support posts) and an installed height of 42 inches. See base plate via a 1/4 inch continuous fillet weld on all four Table 2 for qualified configurations. sides.See Figure 7. 01) 545 E.Algonquin Road •Arlington Heights• Illinois•60005 intertek.com/building .«F 'E° Intertek PCA-101 Version:21 December 2017 SFT-CCRR-OP-40b Code Compliance Research Report CCRR-0202 Page 2 of 7 3.6 An IRC Crossover post is an intermediate post that blocking under the post location and are fastened permits the uninterrupted connection of two top rails between the joists with #10 x 3 inch wood screws in without the interruption of the post profile above the top accordance with the National Design Specification for railings. It consists of a 2.5 inch square by 0.125 inch wall Wood Construction(ANSI/AWC NDS-2012).See Figure 9 extruded tube. The tube is connected to a 4 inch square by for spacing and quantities. 1/2 inch thick aluminum base plate via a '/4 inch continuous fillet weld on all four sides. See Figure 8. 5.4.4 A 3/8 inch thick, 4.5 inch square aluminum back plate is installed on the underside of the wood blocking 3.7 A support block is installed between the lower rail and as illustrated in Figure 9. This aluminum plate shall be the deck surface midway between supports.See Figure 5. factory painted or given a heavy coat of alkali-resistant bituminous paint to provide separation between any 4.0 PERFORMANCE CHARACTERISTICS wood,fiberboard,or other porous material that absorbs water and the aluminum. 4.1 The guardrail system described in this report has demonstrated the capacity to resist the design loadings 5.5 Decking shall be Trex° Transcend® deck boards (solid specified in Section R301 of the IRC when tested in or grooved)or decking equivalent in compressive strength. accordance with ICC-ES AC273. Hollow, ribbed or decking that is of less compressive strength is not suitable for post mount installation. 5.0 INSTALLATION 6.0 CONDITIONS OF USE 5.1 The Trex®Signature®/Trex® Reveal' Railing must be installed in accordance with the manufacturer's published 6.1 Installation must comply with this Research Report, installation instructions, the applicable Code, and this the manufacturer's published installation instructions, and Research Report. A copy of the manufacturer's instructions the applicable Code. In the event of a conflict,this report must be available on the jobsite during installation. governs. 5.2 The top and bottom rails are attached directly to 6.2 Attachment of guardrail systems described herein to structural posts utilizing cast Zamak 3 mounting brackets conventional wood supports is outside the scope of this via mechanical fasteners.See Figure 6 and Table 3. report. 5.3 Aluminum balusters are inserted into routed holes in 6.3 Where required by the building official, engineering the aluminum rails and secured via PVC rail inserts that are calculations and details shall be provided.The calculations installed internally to the rails.See Figure 3 and 4. shall verify that the anchorage and supporting structure complies with the building code for the type and condition 5.4 The Trex' Signature' / Trex® Reveal' Railing is of the supporting construction. attached to 2.5 inches square aluminum post mounts which may be surface mounted to a wood deck. 6.4 Stainless steel shim plates are used to prevent direct contact between the structural post base plate and 5.4.1 The Trex®Signature®/Trex®Reveal'Railing 2.5 supporting structure. inch post mount may be mounted to a wood deck in accordance with the details in Figure 9. 6.5 Compatibility of fasteners and other metallic components with the supporting structure, including 5.4.2 A minimum of four 3/8 inch diameter,6 inch long chemically treated wood, is outside the scope of this anchor bolts must be used and located in the four pre- report. drilled holes in the structural post base plate. 6.6 The Trex® Signature® / Trex® Reveal" Railing is 5.4.3 Pressure-treated 2x8 Southern Yellow Pine manufactured under a quality control program with (specific gravity 0.50 or better) boards are used as inspections. 545 E.Algonquin Road •Arlington Heights•Illinois•60005 4 intertek.com/building `'`Y1P Intertek PCA-101 Version:21 December 2017 SFT-CCRR-OP--40b Code Compliance Research Report CCRR-0202 Page 3 of 7 7.0 SUPPORTING EVIDENCE 9.0 OTHER CODES 7.1 Drawings and installation instructions submitted by This section is not applicable. Trex Company,Inc. 10.0 CODE COMPLIANCE RESEARCH REPORT USE 7.2 Reports of testing demonstrating compliance with the performance requirements of ICC-ES AC273, Acceptance 10.1 Approval of building products and/or materials can Criteria for Handrails and Guards,revised March 2016. only be granted by a building official having legal authority in the specific jurisdiction where approval is sought. 7.3 Documentation of an Intertek approved quality control system for the manufacturing of products recognized in 10.2 Code Compliance Research Reports shall not be used this report. in any manner that implies an endorsement of the product by Intertek. 8.0 IDENTIFICATION 10.3 Reference to the https://bpdirectorv.intertek.com is The Trex® Signature® / Trex® ReveaPT Railing is identified recommended to ascertain the current version and status with the manufacturer's name (Trex Company, Inc.), address of this report. and telephone number, the product name (Trex®Signature® /Trex®Reveal ' Railing), the statement "For Use in One-and Two-Family Dwellings Only.", the Intertek Mark as shown below, and the Code Compliance Research Report number (CCRR-0202). CODE COMPLIANCE (11D Intertek CCRR-0202 This Code Compliance Research Report("Report")is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Report.Only the Client is authorized to permit copying or distribution of this Report and then only in its entirety,and the Client shall not use the Report in a misleading manner. Client further agrees and understands that reliance upon the Report is limited to the representations made therein. The Report is not an endorsement or recommendation for use of the subject and/or product described herein. This Report is not the Intertek Listing Report covering the subject product and utilized for Intertek Certification and this Report does not represent authorization for the use of any Intertek certification marks.Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek. (C)11545 E.Algonquin Road •Arlington Heights®Illinois•60005 intertek.com/building `"1E° Intertek PCA-101 Version:21 December 2017 SFT-CCRR-OP-40h Code Compliance Research Report CCRR-0202 Page 4 of 7 TABLE 1-PROPERTIES EVALUATED PROPERTY 2015/2012 IRC SECTION Structural Performance R301.5 TABLE 2—CODE OCCUPANCY CLASSIFICATION Guardrail Maximum System Type Guardrail Support Post Mount System Code Occupancy Classification Dimensions1J Trex" 2.5 inch The use of this product shall be limited to Signature°/ Mounted to Trex® 96 inches by Aluminum surface of exterior or interior use as a guard system for Level Reveal"" 42 inches Post Mount wood deck(2) dwellings constructed in accordance with Railing System (Figure 7) the IRC(One-and Two-Family Dwellings). (1) Guardrails are qualified up to and including the listed maximum guardrail system dimensions for use in the referenced Code Occupancy Classification. Guardrail lengths are actual railing lengths, i.e. clear space between supports for level rails. Guardrail height is walking surface to top of top rail.Minimum installed height shall be 36 inches. (2) The 2.5 inch aluminum post mount attachment to surface of wood deck must be in accordance with the wood deck support blocking as depicted in Figure 9. Decking shall be Trex® Transcend® deck boards (solid or grooved) or decking equivalent in compressive strength. Hollow, ribbed or decking that is of less compressive strength is not suitable for post mount installation. TABLE 3-TREX°SIGNATURE°/TREK.REVEAL"'RAILING FASTENER SCHEDULE Connection Fastener Top Rail Bracket to Post Three#10-16 by 5/8 inch pan-head,self-drilling stainless steel screws Bottom Rail Bracket to Post Two#10-16 by 5/8 inch pan-head,self-drilling stainless steel screws Top Rail Bracket to Rail Bottom Rail Bracket to Rail One#10-16 by 5/8 inch pan-head,self-drilling stainless steel screws Picket to Rail The picket at the midpoint of rail length is attached to the top and bottom rails using two#8- 15 x 1.25 inch pan-head,stainless steel screws through screw bosses. Foot Block to Bottom One#12-11 by 1.25 inch pan-head self-drilling stainless steel screws Rail Top Rail to Crossover Post 5/16"Diameter x 2"bolt and nut into Wedge Plate(see Figure 8) Top Rail to Crossover #10 x 5/8"long self-drilling screw each side of adapter into railing(see Figure 8) Adapter 545 E.Algonquin Road •Arlington Heights•Illinois•60005 intertek.com/Building - lntertek PCA-101 Version.21 December 2017 SFT-CCRR-OP-40b le Code Compliance Research Report CCRR-0202 Page 5 of 7 1.740 L 1.740 363 .300 F 1 r ." 1.71T _m__. i. 11-----1.564-.....__.-. I i1.564 f i r 1 `` 1.296 1.162 Li 1.364-....__.... ----'—.1.740 FIGURE 1—TOP RAIL FIGURE 2—BOTTOM RAIL c 0.750 .750 j 1 75i0 I ...9 .060 .053 0.75 Round 0.75"Square FIGURE 3—ALUMINUM BALUSTERS .884'__= �. $ I .050 960 .: �I ..{" I FIGURE 4—PVC RAIL INSERT FIGURE 5—TWO PIECE RAILING SUPPORT 'II IV 11411‘14.4 4it , 10,,,s., • 0 Top Mount Bottom Mount FIGURE 6—ZAMAK 3 CAST MOUNTING BRACKETS 011) 545 E.Algonquin Road•Arlington Heights•Illinois•60005 _ intertek.com/building L4 s Intertek PCA-1O1 I Version:21 December 2017 SFT-CCRR-OP 40b Code Compliance Research Report CCRR-0202 Page 6 of 7 2.s-- i 1 2.5 --0.125 Cross section of 2.5"x 2.5"post (For 36"Tall)37 0.406 T rw (For 42"Tall)43 i51 P�2,f5 I 400 l 4,00 0 • .50 O 0 I Plate thickness L544-1-130 TvR. I 1/4"weld on post and on plate \ Cross section of on all 4 skies / Pte it FIGURE 7—2.5 INCH SQUARE ALUMINUM SUPPORT POST Crossovera` Cover Top Rail/Cover 4' TLI1 Screw Bolt ,4.;‘,.'•-%-„i; Crossover 4 t Nut , Adapter 4i Crossover Crossover . Wedge • 2y" 111WedgePlate g DETAIL CROSSOVER cONnECTIOtt SCALE.6 r s s� Overall Height: 42"Railing 39'/2"Post 36"Railing 33th"Post ¼'x¼"Welded all 4 sides full length to DETAIL A Pr plate SCAIE 0.6:1 Plate FIGURE 8-TREX•CROSSOVER POST ASSEMBLY 545 E.Algonquin Road •Arlington Heights•Illinois•60005 intertek.com/building Intertek PCA-101 Version:21 December 2017 SFT-CCRR-OP-40b aCode Compliance Research Report CCRR-0202 Page 7 of 7 . r .. .-, § - 11111111.1 4.50" - - (-) : SYM. 3/8" Aluminum Back Plate ,..._.",,,--- , , shim i 1 11 3.50" Wood Deck Install Detail Stainless Steel Shim Plates 212 i. I I r 2...r ...1 • • • ' PRESSURE TREATED • I ,2 cSYP(G 0:01 gt;BLOCKING OlY 2 STk 1 I 11. 3 I. 1 • • _L__ __L _L____. I Blocking 8' 8,- ,,,,,,,_ boards ......„0 ..". --...7-7.,,,7- -sot • ----"'—... h--6 ±6.---1 ...„- - -.3-..,--___-- • __I---T_, " '';',."':;••os.:;;; *,,,:-A,,,, ,-,--;""'- ' ''..-" . . • 21. 1 2 '...4. 1i,r,* -''' ,.5-KIIIPatil -„...;;-::';'<,... ......• • —7, , ,:e.,”'`,7,--,;,,,,,y,W. - - ---,, --r..--• -- , — , *NO x 3"WOOD SCREWS Wood Blocking Detail FIGURE 9—POST MOUNT INSTALLATION ON WOOD DECK OD 545 E.Algonquin Road•Arlington Heights• Illinois•60005 intertek.com/building ....m., SOILS <tr./ WIIEWFD Intertek PCA-101 Version:21 December 2017 SFT-CCRR-OP-40b