Loading...
Report tot ECzo 19- 00--/59 ( 1 Oct 0 cul 44i PW>' Ai r ' F2P9 ,tVGON Aliet.ltill., _ ....., _ _ 7_ \\\ JOHN;-,' " ON AIR PRODUCTS $1 irst, NIC;Z:=7Ir .... 21 ,S!) 1/4; 44, ,.,,... ,--_--- iii: SUBMITTAL 0 Booster Fans by Reversomatic Project: Red Rock - Tigard Project Address: 11090 SW 68th Pkwy Tigard, OR 97223 Architect: Carleton/Hart Architecture, P.C. Engineer: Fred E. Shaub, Engineer General Contractor: LMC Construction Mechanical Contractor: Mill Creek Heating Date: 10/24/2019 Project: Red Rock - Tigard Project ID: P18-0988 JOHNSON AIR PRODUCTS Table of Contents Tab Submittal Spec/Sub Page# 1 Booster Fans by Reversomatic M0.02 tld-200es-1-inle-1 4 LT-180-n-180F-New 6 Das-250 7 Project: Red Rock - Tigard Project ID: P18-0988 • JOHNSON AIR PRODUCTS Spec Section: M0.02 Typical Dryer Booster Fan Schedule Submittal Name o c3 Booster Fans by Reversomatic 0 Vendor/Subcontractor Johnson Air Products u_ m REVERSOMATIC MANUFACTURING LIMITED TLD-200ES March,2008 GENERAL PURPOSE INLINE AND DRYER EXHAUST FAN TLD-200ES (1 inlet) FAN DATA • Self cleaning, non overloading wheel. 2.00 -- ., • Engineered for quiet continuous operation 0 _ ■ IN ■ making it perfect for general purpose ventilation L 1.50 ., and dryer exhaust application. v �� • Low profile construction simplifies installation in ■■ those tight spaces. a 1.00 ., • Built with a well balanced motor impeller assem- ■ Nil a ■ ■ milin wi'Lmil bly, and a backward inclined wheel for smooth o.so quiet operation. IIIIIIIIIII• High efficiency motor. 0.00 '. • Optional hinged impeller for ease of cleaning and 50 100 150 200 250 maintenance. Air Flow(CFM-Cubic Feet Per Minute) • Available with one,two and three inlets. • Fan housing constructed of heavy gauge satin coat galvanized steel finish. TLD-200E5 (2 inlets) FAN DATA • The logical choice for use in high-rise condo- minium applications. 2.00 — • Certified by California Energy Commission in E • �■ accordance with California Law Title 20. 5 1.50 -----1- • • Also meets Washington State Ventilation and - a Indoor Air Quality Code. a 1.00 ii V Re ,,, 4, t ',.,,,k,r, v 0.50 • • : � � �` .. „-` 0.00 ••• 50 100 150 200 250 Air Flow(CFM-Cubic Feet Per Minute) j R �.' •{tom ' t. /® . 2100 ,, !PA Via: . HVI C USCERTIFIED/ ENERGY STAR Reversomatic Manufacturing Ltd. 790 Rowntree Dairy Road,Woodbridge,ON Canada L4L 5V3 • Tel:905-851-6701 • Fax:905-851-8376 www.reversomatic.com • info@reversomatic.com TLD-200E5 / . *,,::::-Ii::' 5"dia. 11" j . . 10.5" 1. 7.5" I 5"dia. IL , , V ,i 5"dia. 0 5"dia. ELECTRICAL KNOCKOUT / t10.5" N Also available in stainless steel construction for gas dryer. HVI CERTIFIED RATINGS MODEL CFM @ 0.20"S.P. TLD-200ES(2 inlets) 220 FAN DATA QTY:(8) TAG: DBF-1 MODEL MOTOR 120 VAC 60 Hz CUBIC FEET PER MINUTE AlRPM AMPS WATTS S.P. 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.80 1.00 1.25 1.50 1.75 2.00 TLD-200E5 11 inlet) 2500 0.70 78 CFM 232 221 212 205 196 188 179 160 144 119 92 73 37 TLD-200E5(2 inlets) 2500 0.70 78 CFM 249 236 227 220 210 202 193 173 155 130 106 81 40 RPM(Revolution Per Minute)shown is nominal and performance is based on actual speed of test. Contractor: TLD-200ES Architect: Job: Date Supersedes Drawing NO. Engineer: Date Submitted: Reversomatic Manufacturing Ltd. 790 Rowntree Dairy Road,Woodbridge,ON Canada L4L 5V3 • Tel:905-851-6701 • Fax:905-851-8376 www.reversomatic.com • info@reversomatic.com ,e '' REVERSOMATIC MANUFACTURING LIMITED QTY:(8) TAG: LINT TRAP LT-180 March 2016 LINT TRAP SURFACE MOUNTED LT-180 is equipped with _ filter frame attached to the removable door for easy operation. Model LT180-45 lint trap has 4" dia. inlet for dryer connection and 5" dia. outlet for better performance. . Also available in 4" dia. outletofr, (Model # LT-180-44). Please specify when ordering. New Filter for DIMENSIONS: better Performance 4"dia. A. iI I r - , 1 REMOVABLE pA„. PLEXIGLASS COVER 7'/:" 7" 6" 4 1-- 1 � , I I - 6" —.-1 4"dia. FILTER ATTACHED TO P/G COVER CO6'/z' Special sizes are available upon request L Contractor: LT-180 Architect: Job: Date Supersedes Drawing No. Engineer: Date Submitted: Reversomatic Manufacturing Ltd. 790 Rowntree Dairy Road,Woodbridge,ON Canada L4L 5V3•Tel:905-851-6701• Fax:905-851-8376 www.reversomatic.com • info@reversomatic.com 3 REVERSOMATIC ,,, MANUFACTURING LIMITED QTY:(8) TAG: AMP SENSOR DAS-250 March, 2017 DRYER AMP SENSOR FAN CONTROL WITH SURGE PROTECTION AND TIME ,r-__ 13 DELAYED "SHUT-DOWN" / Ti CLOMMIIIENIT The DAS-250 Dryer Fan Control is a solid-state N.O. high swirelml current AC switch that operates a dryer booster fan Eel directly.This device senses when a clothes dryer is draw- cw ing 1.2 Amp(± 20%-25%)of current and then closes the output switch to activate the dryer vent booster fan. When • the dryer cycle is complete and the current drops below • -rr the threshold, the output switch will remain closed for 5 minutes to allow heat to be removed from the vent before the switch is opened again.The DAS-250 requires no field adjustments and only two wire connections for 0 3/4" LJ easy installation. The device output will switch loads at 120 VAC and 3.5 Amp. maximum. The internal circuits of DAS-250 are totally powered by induction from the line being monitored and all units are CSA Certified to Cana11111121,2. dian and US Standards. The high current switch with surge voltage protection meet IEEE 62.41-1991 standards. r— —, The sensor is designed to mount in a standard electrical 03/16„ } 3• t 11'8 box. The AMP Sensor may be placed in an electrical box Li 0 adjacent to the junction box in which the wires supplying power to the dryer are located (see back of this page). 1E1 bidd The dryer supply neutral (white)wire passes through the center of the AMP Sensor donut. No physical connection 1 31/2 } is made. SPECIFICATIONS NOTE:Action Current Range: 1.20-60 Amp.-turns AC Conductor Hole: 19 mm (0.75")diameter Installation by a licensed electri Trip Set-Point: Pre-set at approximately 1.2A cian is recommended. Installa Switch Rating: 120 VAC 3.5A max. tion and use of this equipment Output Type: should be in accordance with P yP Triac with volts surge protected design provisions of the national Output 0 ffDelay Time: 4.5-5 minutes electrical code. Applicable local Operating Temperature: -5 - +40° C (23 - 104° F) codes and pertinent industry Operating Humidity: 0 - 99% standards should be verified Dimensions: H63 x W89 x D28 mm (2.5"x 3.5"x 1.1") before installation. Mounting Holes: 2 x 5 mm (2 x 0.19") holes spaced 76 mm (3")on base Leakage Current: < 1 mA Manufacturing Process: ISO 9001 Certified Standards Met: CSA No.14-2005 edition, UL 508, FCC, IEEE 62.41-1991 Reversomatic Manufacturing Ltd. 790 Rowntree Dairy Road,Woodbridge,ON Canada L4L 5V3 • Tel:905-851-6701 • Fax:905-851-8376 www.reversomatic.com • info@reversomatic.com DAS-250 TURN POWER OFF AT CIRCUIT BREAKER OR FUSE PANEL BEFORE INSTAL INSTALLATION INSTRUCTIONS INSTALLATION TYPE 1 (at dryer junction box) TWO TURNS NEUTRAL/WHITE 1. Attach electrical junction box to the dryer junction box. / \/ 2. Disconnect and loop neutral (white)dryer power supply POWER TO DRYER_ FAN _ wire through center of sensor as shown then back to the t Q , (� (MAX.3.5 Amp.) dryer junction box anile-connect. - ,_-.7 .--1 3. Mount sensor in the electrical box (two holes may have \ AMP SENSOR 120 VAC/60 Hz to be drilled for mounting). DRYER JUNCTION BOX 4. Connect fan 120 VAC power supply to the top (relay) NOTE: terminals of the sensor. If the dryer cooling motor is less than 0.6 Amp.,you may have to increase numbers of turns to operate AMP Sensor switch. But make sure numbers of turns multiply by dryer max.input current(AMP) INSTALLATION TYPE 2 must be less than 60 Amp.(see action current range on page 1) (at fuse/breaker panel) FUSE/BREAKER PANEL TWO TURNS 1. Mount sensor at a convenient location on the fuse/breaker panel. 120 VAC 0 �1FAN 2. Disconnect and loop neutral (white) dryer power supply NEUTRAL/WHITErrAZNIErLLm (MAX'3.5 Amp.) wire through center of sensor then re-connect. e AMP SENSOR 3. Connect fan 120 VAC power supply to the top (relay) POWER TO DRYER -„� terminals of the sensor. = II—, 0 p • = DRYER JUNCTION BOX INSTALLATION TYPE 3 (inside dryer compartment) 1. Mount sensor in a convenient location inside the dryer DRYER connection compartment. DRYER JUNCTION BOX 2. Disconnect and loop neutral (white) dryer power supply wire through center then re-connect. 111TO FAN AND 120 VAC 3. Connect fan 120 VAC power supply to the top (relay) TERMINAL BLOCK ` (MAX.3.5 Amp.) terminals of the sensor. _.........,____.„- ;, NEUTRAL/WHITE , li#1111 itior INSTALLATION TYPE 4 TWO TURNS ....... ... MP (for stacker dryer C/W common power supply -US only) Stacker Dryer that has separate power supply for dryer and washer, use instruction 1,2 or 3. WHA • POWER SUPPLY TO DRYE BOOST RRFAN BLACK • THE BOOSTER FAN (MAX.3.5 Amp.) GREEN 120 VAC/60 Hz TWO TURNS EC-1520D If the stacker dryer max. input current is less than 20 Amp. and (SURGE PROTECTED) the dryer cooling motor is less than 0.6 Amp., you may have to DRYER(MAX.23 Amp.) HEATING COI RED • increase numbers of turns to operate AMP Sensor switch.But make sure numbers of turns multiply by dryer max.input current(Amp.) COOLING 0AMP SENSOR BLACK must be less than 60 Amp.(see action current range on page 1) COOLING 0 MOTOR 0.6 Amp. WHITE • POWER SUPPLY TO THE STACKER DRYER GREEN 1 (C/W COMMON POWER SUPPLY FOR DRYER&WASHER) 230 VAC/60 Hz BLACK WASHER WHITE Reversomatic Manufacturing Ltd. 790 Rowntree Dairy Road,Woodbridge, ON Canada L4L 5V3 • Tel:905-851-6701 • Fax:905-851-8376 www.reversomatic.com • info@reversomatic.com „ ,,,i h! ic _ t v vi ED NO'l 5 2019 BUILUi G DIViSION ___-------- , 7--- JOHN;----,H ON AIR PRO DUCTS SUBMITTAL Ceiling Fans by Panasonic Project: Red Rock- Tigard Project Address: 11090 SW 68th Pkwy Tigard, OR 97223 Architect: Carleton/Hart Architecture, P.C. Engineer: Fred E. Shaub, Engineer General Contractor: LMC Construction Mechanical Contractor: Mill Creek Heating Date: 10/24/2019 Project: Red Rock - Tigard Project ID: P18-0988 JOHNSON AIR PRODUCTS Table of Contents Tab Submittal Spec/Sub Page# 1 Ceiling Fans by Panasonic M0.02 FV-0511 VKS2_Submittal 4 FV-0511 VK2_Submittal 6 FV-1115VK2 Submittal 8 Project: Red Rock - Tigard Project ID: P18-0988 AIR PRODUCTS Spec Section: M0.02 Fan Schedule Submittal Name 0 c Ceiling Fans by Panasonic 0 cts Vendor/Subcontractor Johnson Air Products 0 w 0) E iii U 0 ca H [A `r i e r Built-In Self Adjusting VENTILATION FAN Airflow Capability FV-0511 VKS2 Specification Submittal Data /Panasonic Ventilation Fan Description Customizable ceiling mount ventilating fan, low sone and rated for continuous operation. ENERGY STAR®rated and certified by the Home Ventilating Institute(HVI).Evaluated by the 4" or 6" duct Underwriters Laboratories and conforms to both UL and cUL standards. Motor/Blower: •Enclosed brushless ECM smart motor technology rated for continuous operation •Adjustable ventilation rates at 50-80-110 CFM ' (� •Power rating of 120 volts and 60 Hz 1,01 \'I, , 4" •UL and cUL listed for tub/shower enclosure when GFCI protected. �`�f\� •Motor equipped with thermal cutoff fuse 7r UI •Removable permanently lubricated plug-in motor 3is \ !' ,.,i�l����l�l�u' Noosing: Imo` •Environmentally friendly 26 gauge Zinc-Aluminum-Magnesium(ZAM)housing •Integrated dual 4"or 6"diameter duct adapter 101/4.. 101/4" •Built-in damper reduces back draft and helps with blower door testing •Buitt-in metal flange provides blocking for penetrations through drywall as an Air Barrier,and assists with the decrease in leakage in the Building Envelope during blower door testing •Suitable for installation in ceilings insulated upto R60 •Articulating and expandable installation bracket up to 24" Grille: \ •Attractive design using Poly Pro material 13. 13 •Attaches directly to housing with torsion springs • Includes a motion sensor cap for use as a cover when the motion sensor Plug 'n Play'" module has not been selected Warranty: •ECM Motor:6 Years from original purchase date •ALL Parts:3 Years from original purchase date FV-0511 VKS2 Architectural Specifications: Customizable ceiling mount ventilation fan,ENERGY STAR®rated with multi-speed control(0, 30-100 CFM,in 10 CFM increments)and a built-in high/low adjustable time delay activated by a wall switch,SmartAction Motion Sensor Plug'N Play-module or Condensation Sensor Plug'N Performance Curve 4"or 6"duct Play"'module.Features a built-in speed selector.Select from 50/80/110 CFM with<0.3 sone as 0 70 certified by the Home Ventilating Institute(HVI)at 0.1 w.g.with 51/80/110 CFM and no more than 0.4/0.5/0.8 sones at 0.25 w.g.and 51/79/108 CFM at 0.375 w.g.Power Consumption shall be no greater than 3.1/5.1/9.9 watts at 0.1 w.g.and 6.2/9.6/15.4 watts at 0.25 w.g.and 9.6/13.4/20.0 0 60 MI6 —„aM watts at 0.375 w.g.ENERGY STAR®rated with efficiency of no less than 16.2/15.7/11.1 CFM/ watt at 0.1 w.g.and 8.3/8.3/7.1 CFM/watt at 0.25 w.g.and 5.3/5.9/5.4 CFM/watt at 0.375 rim w.g.The motor shall be enclosed with brushless ECM motor engineered to run continuously. a Of —'” ECM motor speed shall automatically increase when the fan senses static pressure to maintain 5 i selected CFM.Power rating shall be 120v/60Hz.Duct diameter shall be no less than 4",inclusive "," of an integrated dual 4"or 6"duct adapter.Plug'N Play"modules provide up to two additional I features.Select from Condensation Sensor,and SmartAction Motion Sensor.Fan shall be RoHS a� ,i I ,- Compliant and UL and cUL listed for tub/shower enclosure when GFCI protected.Also suitable for installation in ceilings insulated up to R60.Fan can be used to comply with ASHRAE 62.2, a' ��®�® `°° LEED,ENERGY STAR®,IAP,EarthCraft,California Title-24 and WA Ventilation Code. ".MEI= .4'P0.T F(04_ ECM Motor Technology: ," =a 3" �" gra b.ICFMI • '" „� „" „� l \ When fan senses static pressure, its speed is automatically increased to ensure that the desired CFM is not compromised, which allows the fan to c1ND\-° perform as rated. Model Quantity Comments Project: FV-0511VKS2 50 TAG: TEF 1 Location: Architect: Engineer: Contractor: Submitted by: Date: For complete Installation Instructions visit us.panasonic.com/ventfans Cuing Radiation Damper:WhisperGreen Select"is UL listed for use with the Panasonic Ceiling Radiation Damper(Model e:PC-RDO5C5,sold separatey). O FV-0511 VKS2 J erl '\ (''. 1 ._ deet Built-In VEATIONN Airflow Capability Plug 'N PlayTM Modules Plug 'N Play" modules provide up to two additional features (multi-speed is already built-in to FV-0511VKS2). Select from Motion Sensor and Condensation Sensor. FV-VS15VK1: Multi-Speed with Time Delay - N/A for this Fan, already built-in. IIII Allows you to select the proper CFM settings to satisfy ASHRAE 62.2 continuous ventilation requirements. The fan runs continuously at a pre-set lower level(0,30-100 CFM,in 10 CFM increments),then elevates to a maximum level of operation (50-80-110 CFM)when the wall switch is turned on,or when the motion sensor or Condensation Sensor module is activated. A High/Low delay timer returns the fan to the pre-set CFM level after a period of time set by the user. FV-MSVK1: Motion Sensor Automatically activates when someone enters the room.Once the settings have been applied,th- .- •ecomes truly automatic. .....,..* •' module also activates a 20 minute delay off timer for the fan. FV-CSVK1: Conden - '• Sensor Helps control.. •om condensation to prevent mold and mildew.Sens. : a nology detects relative humidity and temperature • to.• ' 'sate dew point,automatically turning the fan on to control humidity.Built-in--: ' e Humidity(RH)sensitivity adjustment enables fine tuning for moist conditions and for satisfying CalGreen requirements.When the :•••nsation sensor is used in ,...• conjunction with multi-speed functionality,the fan will kick up to high speed when the condensation se : •etects moisture in the room.This module also activates a 20 minute delay off timer for the fan. Fan Specifications W isperGreen Selectt':FV-051 1VK Static Pressure in inches w.g. 0.1 0.25 0.375 0.1 0.25 0.375 0.1 0.25 0.375 0.1 0.25 0.375 0.1 0.25 Air Volume(CFM) 110 110 108 100 101 101 90 90 90 80 80 79 70 71 Noise(sones) <0.3 0.8 - <0.3 0.7 - <0.3 0.6 - <0.3 _ 0.5 - <0.3 0.5 Power Consumption(watts) 9.9 15.4 20.0 7.9 13.1 17.8 6.5 11.2 16.0 5.1 9.6 13.4 4.3 8.5 Energy Efficiency(CFM/Watt) 11.1 7.1 5.4 12.7 7.7 5.7 13.9 8.0 5.6 15.7 8.3 5.9 16.7 8.5 Speed(RPM) 920 1182 1356 889 1164 1356 839 1135 1351 795 1113 1315 760 1112 Current(amps) 0.10 0.16 0.20 , 0.09 0.14 I 0.18 0.07 0.12 0.16 0.06 0.10 0.14 0.05 0.09 MAX.Current(amps) 0.20 Power Rating(V/Hz) 120/60 ENERGY STAR rated Yes 0.375=Installed Performance Panasonic Eco Solutions Company of North America Eco Products Division Most Efficient Two Riverfront Plaza -2018 Newark,NJ 07102 MMEI,,,,,, .energysbcgav us.panasonic.com/ventfans ; c us Panasonic VF18972SS-FV-o511VKS2 NASA nip C Whis er�� . , SeCee� $Din-In SettAdluatlng FV-0511 VK2 VENTILATION FAN AirflowCapa6ihty Specification Submittal Data/Panasonic Ventilation Fan Description Customizable ceiling mount ventilating fan,low sone and rated for continuous operation. ENERGY STAR®rated and certified by the Home Ventilating Institute(HVI). Evaluated 4" or 6" duct by the Underwriters Laboratories and conforms to both UL and cUL standards. Motor/Blower: •Enclosed brushless ECM smart motor technology rated for continuous operation c •Adjustable ventilation rates at 50—80—110 CFM I • 'Al •Power rating of 120 volts and 60 Hz •UL and cUL listed for tub/shower enclosure when GFCI protected •Motor equipped with thermal cutoff fuse 73'8' :(3'8 ( •Removable permanently lubricated plug-in motor ,- • Housing: •Environmentally friendly 26 gauge Zinc-Aluminum-Magnesium(ZAM)housing •Integrated dual 4"or 6"diameter duct adapter 10 1/4° 10 1/4" •Built-in damper reduces back draft and helps with blower door testing •Built-in metal flange provides blocking for penetrations through drywall as an Air Barrier,and assists with the decrease in leakage in the Building Envelope during blower door testing /`\\\ •Suitable for installation in ceilings insulated up to R60 •Articulating and expandable installation bracket up to 24" Grille: l3' VII 13. •Attractive design using Poly Pro material •Attaches directly to housing with torsion springs •Includes a motion sensor cap for use as a cover when motion sensor Plug'n Play-module has not been selected Warranty: •ECM Motor:6 Years from original purchase date FV-0511VK2 •ALL Parts:3 Years from original purchase date Architectural Specifications: Customizable ceiling mount ventilation fan, ENERGY STAR® rated with built-in speed selector.Select from 50/80/110 CFM with<0.3 sone as certified by the Home Ventilating Performance Curve 4"or 6"duct Institute(HVI)at 0.1 w.g. with 51/80/110 CFM and no more than 0.4/0.5/0.8 sones at " ro 0.25 w.g.and 51/79/108 CFM at 0.375 w.g.Power Consumption shall be no greater than 9.9/7.9/6.5 watts at 0.1 w.g.and 15.4/13.1/11.2 watts at 0.25 w.g. and 9.6/13.4/20.0 watts at 0.375 w.g.ENERGY STAR®rated with efficiency of no less than 16.2/15.7/11.1 CFM/watt at 0.1 w.g.and 8.3/8.3/7.1 CFM/watt at 0.25 w.g.and 5.3/5.9/5.4 CFM/watt ► "" at 0.375 w.g.The motor shall be enclosed with brushless ECM motor engineered to run :'• continuously. ECM motor speed shall automatically increase when the fan senses static o." M pressure to maintain selected CFM.Power rating shall be 120v/60Hz.Duct diameter shall f be no less than 4",inclusive of an integrated dual 4"or 6"duct adapter.Plug'N Play'" �� N �, modules provide up to three additional features.Select from Multi Speed with Time Delay, l Condensation Sensor,and Motion Sensor.Fan shall be RoHS Compliant and UL and cUL ° listed for tub/shower enclosure when GFCI protected.Also suitable for installation in ceilings •//' 11111111 4.4011. insulated up to R60. Fan can be used to comply with ASHRAE 62.2, LEED, ENERGY "•".' STAR®IAP,EarthCraft,California Title-24 and WA Ventilation Code. a ‘. I M, Fto ECM Motor Technology: " 20 • w % wicFMS" • • „" " i y, • ECM When fan senses static pressure, its speed is automatically increased to ensure that the desired CFM is not compromised,which allows the fan to FQNr,o‘-'° perform as rated. Model Quantity Comments Project FV-0511VK2 11 TAG:EF 1-3 , 1-5, 2-1, Location: ' 2-3 , 2-4 , 3-1, 3-3 , 3-4, Architect: 4-1, 4-3 , 4-4 Engineer: Contractor: Submitted by: Date: For complete Installation Instructions visit us.panasonic.com/ventfans Catling Radiation Damper:whisperGreen Select"is UL holed for use with the Panasonic Ceiling Radiation Damper(Model#:PC-RDO5C5,sold separately). -oPt FV- _ . BunSelfAdjusting1JlETNer Airflow Capability TM P z 'N Play'modules provide up to three additional features.Select from Multi-Speed with Time Delay,Motion Sensor,and Condensation S-• •r. FV-VS15VK1: Multi-Speed with Time Delay 1011 • •ws you to select the proper CFM settings to satisfy ASHRAE 62.2 continuous v-- ation requirements. The fan runs contin c sly at a pre-set lower level(0,30-100 CFM,in 10 CFM increments),th-• -evates to a maximum level of operation (50-80-110 t when the wall switch is turned on,or when the motion s- .r or Condensation Sensor module is activated. A High/Low delay --r returns the fan to the pre-set CFM level afte - •eriod of time set by the user. FV-MSVK1: Motion Sens• Automatically activates when someone- ers th- •om.Once the settings have been applied,the fan becomes truly automatic. This module also activates a 20 ute delay off timer : the fan. r'•-CSVK1: Condensation Sensor Helps control bathroom condensation to prevent mold and mildew.Sensor technology detects re. -humidity and temperature •+ to anticipate dew point,automatically turning the fan on to control humidity.Buitt-in Relative Humidity(•• ensitivity adjustment enables fine tuning for moist conditions and for satisfying CalGreen requirements.When the condensation -- sor is used in us conjunction with multi-speed functionality,the fan will kick up to high speed when the condensation sensor detec oisture in the room.This module also activates a 20 minute delay off timer for the fan. Fan Specifications WhisperGreen Select'"FY-051 1VK2 Static Pressure in inches w.g. 0.1 0.25 0.375 0.1 0.25 0.375 0.1 0.25 0.375 Air Volume(CFM) 110 110 108 80 80 79 50 51 51 Noise(sones) <0.3 0.8 - <0.3 0.5 - <0.3 0.4 - Power Consumption(watts) 9.9 15.4 20.0 5.1 9.6 13.4 3.1 6.2 9.6 Energy Efficiency(CFM/Watt) 11.1 7.1 5.4 15.7 8.3 5.9 16.2 8.3 5.3 Speed(RPM) 920 1182 1356 795 1113 1315 722 1054 1266 Current(amps) 0.10 0.16 0.20 0.06 0.10 0.14 0.04 0.07 0.10 MAX.Current(amps) 0.20 Power Rating(V/Hz) 120/60 ENERGY STAR rated Yes 0.375.-Installed Performance Fan Specifications WhisperGreer Select":FV-0511VK2+FV-VS 5VK1 (Multi peed Plug'N Play Module) Static Pressure in inches w.g. 0.1 0.25 1.375 0.1 0.25 1.37 0.1 0.25 1.375 0.1 0,25 1.375 0.1 0.25 0.375 0.1 0.25 0.37 0.1 0.25 1.37 0.1 0.25 1.37 0.1 0.25 1.37 Air Volume(CFM) 110 110 108 100 101 101 90 90 90 80 80 79 70 71 70 60 60 60 50 51 51 40 41 40 30 30 30 Noise(sones) <0.3 0.8 - <0.3 0.7 - <0.3 0.6 - <0.3 0.5 - <0.3 0.5 - <0.3 0.4 - <0.3 0.4 - <0.3 0.3 - <0.3 0.3 - Power Consumption(watts) 9.9 15.4 20.0 7.9 13.1 17.8 6.5 11.2 16.0 5.1 9.6 13.4 4.3 8.5 12.1 3.7 6.9 10.5 3.1 6.2 9.6 2.7 5.5 7.8 2.4 4.6 6.8 Energy Efficiency(CFM/Watt) 11.1 7.1 5.4 12.7 7.7 5.7 13.9 8.0 5.6 15.7 8.3 5.9 16.7 8.5 5.9 16.3 8.7 5.7 16.2 8.3 5.3 14.8 7.4 5.1 12.6 6.6 4.4 Speed(RPM) 920 1182 1356 889 1164 1356 839 1135 1351 795 1113 1315 760 1112 1309 751 1061 1287 722 1054 1266 707 1057 1251 711 1039 1259 Current(amps) 0.10 0.16 0.20 0.09 0.14 0.18 0.07 0.12 0.16 0.06 0.10 0.14 0.05 0.09 0.13 0.05 0.08 0.11 0.04 0.07 0.10 0.04 0.07 0.09 0.04 0.06 0.08 MAX.Current(amps) 0.20 Power Rating(V/Hz) 120/60 ENERGY STAR rated Yes 0.375=Installed Performance Panasonic Eco Solutions Company of North America M Most Efficient Eco Products Division 218 Two Riverfront Plaza Newark,NJ 07102 =www•n<rer+r•r.eo• us.panasonic.com/ventfans 51)c Us Panasonic VF189725S-FV-0511VK2 °,1a5oy 'cry `A y�0° FV-1115VK2 i p e r i E,'.1eeeet Built-In Self Adjusting VENTILATION E FAN // Airflow Capability Specification Submittal Data /Panasonic Ventilation Fan Description Customizable ceiling mount ventilating fan,low sone and rated for continuous operation. ENERGY STAR®rated and certified by the Home Ventilating Institute(HVI).Evaluated by 6 duct the Underwriters Laboratories and conforms to both UL and cUL standards. Motor/Blower: •Enclosed brushless ECM smart motor technology rated for continuous operation th, , e•Adjustable ventilation rates at 110—130—150 CFM•Power rating of 120 volts and 60 Hz „: 11--- c• (. ...T.,p UL and cUL listed for tub/shower enclosure when GFCI protected +•Motor equipped with thermal cutoff fuse ��•Removable permanently lubricated plug in motor 3/sy�r[��.I IIIIII,) • �� \= Housing: _;011 .''.' •Environmentally friendly 26 gauge Zinc-Aluminum-Magnesium(ZAM)housing ✓, •Integrated dual 4"or 6"diameter duct adapter •Built-in damper reduces back draft and helps with blower door testing 101/4" 101/4" •Built-in metal flange provides blocking for penetrations through drywall as an Air Barrier,and assists with the decrease in leakage in the Building Envelope during blower door testing •Suitable for installation in ceilings insulated up to R60 •Articulating and expandable installation bracket up to 24" \�\ Grille: V1p •Attractive design using Poly Pro material � •Attaches directly to housing with torsion springs 13° 13 •Includes a motion sensor cap for use as a cover when the motion sensor Plug'n PIayTM module has not been selected Warranty: •ECM Motor:6 Years from original purchase date •AL1 Parts:3 Years from original purchase date Architectural Specifications: FV-1115VK2 Customizable ceiling mount ventilation fan, ENERGY STAR® rated with built-in speed selector.Select from 110/130/150 CFM with<0.3 sone as certified by the Home Ventilating Institute(HVI)at 0.1 w.g.with 112/130/151 CFM and no more than 0.3/0.4/0.7 sones at 0.25 w.g.and 105/124/132 CFM at 0.375 w.g.Power Consumption shall be no greater than Performance Curve 6"duct 6.9/9.2/12.9 watts at 0.1 w.g.and 12.8/16.5/22.0 watts at 0.25 w.g.and 17.9/22.1/24.4 °. watts at 0.375 w.g.ENERGY STAR®rated with efficiency of no less than 16.0/14.2/11.7 CFM/watt at 0.1 w.g.and 8.7/7.9/6.8 CFM/watt at 0.25 w.g.and 5.8/5.6/5.4 CFM/watt °r° at 0.375 w.g.The motor shall be enclosed with brushless ECM motor engineered to run Ill continuously. ECM motor speed shall automatically increase when the fan senses static _ pressure to maintain selected CFM.Power rating shall be 120v/60Hz.Duct diameter shall a a oc be no less than 6'.Plug'N Play"modules provide up to three additional features.Select r ,°- \ from Multi-Speed with Time Delay,Condensation Sensor,and SmartAction Motion Sensor. \ Fan shall be RoHS Compliant and UL and cUL listed for tub/shower enclosure when GFCI protected.Also suitable for installation in ceilings insulated up to R60..Fan can be used f,°_°- to comply with ASHRAE 62.2,LEED,ENERGY STAR®IAP,EarthCraft,California Title-240.20 - ,��- `,� „ and WA Ventilation Code. ° MIME _6.0, Un yip.TF<o� ECM Motor Technology: r "°°'° °. �:" 1111111 ECM --,.: When fan senses static pressure,its speed is automatically increased to rF ensure that the desired CFM is not compromised,which allows the fan to Airflow ICFMI %NOV' perform as rated. Model Quantity Comments Project: FV-1115VK2 5 Tags : EF 1-1, 1-2, Location: 2-2, 3-2 ,4-2 Architect: Engineer: Contractor: Submitted by: Date: For complete Installation Instructions visit us.panasonic.com/ventfans Ceding Radiation Damper:whisperGreen Select"is UL listed for use with the Panasonic Ceiling Radation Damper(Model#:PC-RD05C5,sold separately). 0 h s ��' QCQG�'� g -1115VK2 VENTILATION FAN Airflow Capability TM P . 'N Play'modules provide up to three additional features.Select from Multi-Speed with Time Delay,Motion Sensor,and Condensation Senso FV-VS15VK1: Multi-Speed with Time Delay MI - .ws you to select the proper CFM settings to satisfy ASHRAE 62.2 continuous ventila requirements. The fan runs contin•s sly at a pre-set lower level (0,50-120 CFM,in 10 CFM increments),then ele . -s to a maximum level of operation (110-130-1 0 CFM) when the wall switch is turned on, or when the motion - sor or Condensation Sensor module is activated.A High .. delay timer returns the fan to the pre-set CFM level---r a period of time set by the user. FV-MSVK1: Motion Sen f' 1:A Automatically activates when someone enters .-: oom.Once the settings have been applied,the fan becomes truly automatic. This module also activates a 20 minute•-ay ay off time •r the fan. FV-C 1: Condensation Sensor -elps control bathroom condensation to prevent mold and mildew.Sensor technology detects r-:'ve humidity and temperature 0' to anticipate dew point,automatically turning the fan on to control humidity.Built-in Relative Humidity '- sensitivity adjustment enables fine tuning for moist conditions and for satisfying CalGreen requirements.When the condensatio ensor is used in f' conjunction with multi-speed functionality,the fan will kick up to high speed when the condensation sensor de-. moisture in the room.This module also activates a 20 minute delay off timer for the fan. Fan Specifications WhisperGreen Select'":FV-1115VK2 Static Pressure in inches w.g. 0.1 0.25 0.375 0.1 0.25 0.375 0.1 0.25 0.375 Air Volume(CFM) 150 151 132 130 130 124 110 112 105 Noise(sones) <0.3 0.7 - <0.3 0.4 - <0.3 0.3 - Power Consumption(watts) 12.9 22.0 24.4 9.2 16.5 22.1 6.9 12.8 17.9 Energy Efficiency(CFM/Watt) 11.7 6.8 5.4 14.2 7.9 5.6 16.0 8.7 5.8 Speed(RPM) 684 916 1084 645 900 1080 625 _ 894 1083 Current(amps) 0.14 0.22 0.24 0.10 0.17 0.22 0.08 0.13 0.18 MAX.Current(amps) 0.24 Power Rating(V/Hz) 120/60 ENERGY STAR rated Yes 0.375=Installed Performance Fan Specifications FV- 115VK2+FV-VS15VK1 (Multi Spee. Plug'N Play-module) Static Pressure in inches w.g. 0.1 0.25 1.37 0.1 0.25137 0.1 0.25 0:37 0.1 0.25 1.37 0.1 0.25 1.375 0.1 0.25 0.37 0.1 0.25 1.375 0.1 0.25 1.37 0.1 0.25 0.37 0.1 0.25 1.375 Air Volume(CFM) 150 151 132 130 130 124 120 120 122 110 112 105 100 100 97 90 91 90 80 81 80 70 71 70 60 60_60 50 50 50 Noise(sones) <0.3 0.7 - <0.3 0.4 - <0.3 0.3 - <0.3 0.3 - <0.3 0.2 - <0.3 0.3 - <0.3 0.3 - <0.3 0.4 - <0.3 0.4 - <0.3 0.5 - Power Consumption(watts) 12.9 22.0 24.4 9.2 16.5 22.1 7.7 14.0 20.5 6.9 12.8 17.9 5.5 11.0 16.0 4.7 9.7 15.0 4.2 9.0 13.9 3.7 8.1 12.2 3.3 7.2.11.2 3.0 6.4 10.2 Energy Efficiency(CFM/Watt) 11.7 6.8 5.4 14.2 7.9 5.6 15.7 8.6 6.0 16.0 8.7 5.8 18.2 9.1 6.0 19.1 9.3 6.0 19.0 9.0 5.7 19.2 8.8 5.8 18.2 8.3 5.3 17.3 8.1 5.1 Speed(RPM) 684 916 1084 645 900 1080 633 895 1086 625 894 1083 615 898 10931602 9001099 608 912 1104i591 914 1109 608 913 1117 609 910 1116 Current(amps) 0.14 0.22 0.24 0.10 0.17 0.22 0.09 0.15 0.21 0.08 0.13 0.18 0.07 0.12 0.1610.06 0.10 0,15 0.05 0.10 0.1410.05 0.09 0.13 0.04 0.08 0.12 0.04 0.07 0.11 MAX.Current(amps) 0.33 Power Rating(V/Hz) 120/60 ENERGY STAR rated Yes 0.375=Installed Performance Panasonic Eco Solutions Company of North America Most Efficient Eco Products Division 2018 Two Riverfront Plaza Newark,NJ 07102 ill=yyyrty.energnt,r.gOV us.panasonic.com/ventfans Nc us Panasonic J VF18972SS-FV-0511 VK2 F4 m�a;(''I i t.UA J4HNH C ) AIR DUCTS SUBMITTAL Electric Heaters by Qmark/Cadet Project: Red Rock - Tigard Project Address: 11090 SW 68th Pkwy Tigard, OR 97223 Architect: Carleton/Hart Architecture, P.C. Engineer: Fred E. Shaub, Engineer General Contractor: LMC Construction Mechanical Contractor: Mill Creek Heating Date: 10/24/2019 Project: Red Rock - Tigard Project ID: P18-0988 JOHNSON AIR PRODUCTS Table of Contents Tab Submittal Spec/Sub Page# 1 Electric Heaters by Qmark/Cadet M0.03 UH 1-1 and UH B-3 4 UH 1-3, 2-1, 3-1, 4-1 8 TH106 Thermostats for tags UH 1-3, 2-1, 3-1,4-1 10 CH-1 Heaters 11 M602W Thermostats for CH-1 Heaters 13 UH 1-2, B-1, B-2 14 Project: Red Rock - Tigard Project ID: P18-0988 JOHNSON AIR PRODUCTS Spec Section: M0.03 Typical Electric Cove Heater Schedule/Electric Unit Heater Schedule Submittal Name a) Electric Heaters by Qmark/Cadet Vendor/Subcontractor Johnson Air Products U co UNIT HEATERS Qty.(2) #CU935 cabinet unit heaters CU900 SERIES Qty.(2) Std. single stage/single pole remote wall CUSTOM CABINET UNIT HEATER mounted thermostats Tags: UH 1-1; UH B-3 1'5.4 :4 LI Q e.� E-.pyx�} a Y,+` •A' re � � ps-, .:t m • BMS-compatible ■ 16 air inlet/outlet combinations that are all field-changeable ■ One-person maintenance on ceiling applications with hinged front panel '% ■ Cabinet constructed of heavy 16-gauge cold-rolled steel to provide strength and finished with a polyester powder coating for corrosion IDEAL SPACES resistance • Motors are mounted with automatic thermal overload protection; motor • School Hallways • Entrance Ways fuse protection is provided on all heaters to meet safety requirements • Churches ■ Vestibules • Plate fin element-steel fins are copper-brazed to low-watt density, • Transportation • Lobbies steel-sheathed tubular heating elements Terminals • Mechanical • Element is finished with aluminized paint for corrosion resistance • Stairwells Rooms ■ Fins and elements are arranged in a uniform grid pattern and fit closely COLORS into the discharge area to assure that all outgoing air passes through • Neutral Gray • Statuary Bronze the heating element ■ Charcoal Gray • Desert Tan IIIThermal safety cutout- installed with direct contact to the heating element.Automatically shuts off the heater in the event of overheating • Aluminum • Gloss Black reactivates the heater when operating temperature returns to normal • Navajo White • Custom Colors • Built-in thermostat*-single-pole,snap-action thermostat with remote • Northern White Available bulb sensor located directly in the air intake DIMENSIONS ■ Tamper-resistant,two-position selector switch to select full heat at high • 26-3/8"H x 9-3/4"D(length varies) fan speed and reduced heat at low fan speed* • Automatic fan delay eliminates cold drafts on start-up and discharges TEMP RANGE residual heat from the heater body during shut down • 55°-85°F ■ Front cover interlock de-energizes unit when front cover is removed for added safety CFM • Disposable air filter mounted in inlet air stream; optional permanent and • 200-1000 washable aluminum filters available • Standard stamped louvered grilles; optional architectural-style grille available; optional aluminum wall louver available, ideal for exterior 51,1/1,11 Y E A R masonry or panel walls WARRANTY f' US ELEMENT WORKMANSHIP *Optional feature.Contact sales representative or factory regarding optional features available, including:built-in fan switch;120V control,electronically controlled outside air damper;inlet and discharge duct collars;dead-front and fused dead-front disconnect switches;built-in night set back relay;and trim kits.See page 39 to find out how to order cabinet unit heaters. www.gmarkmep.com For Technical Services, Call 800-642-4328 MARK® ITEM#QFLY_CU900_1217-1 A Marley Engineered Products Brand Qty.(2) #CU935 cabinet unit heaters CU900 SERIES Qty.(2) Std. single stage/single pole remote wall CUSTOM CABINET UNIT HEATER mounted thermostats Tags: UH 1-1; UH B-3 MODELS&SPECIFICATIONS FINAL AIR 208 208 24U 24U 277 347 38U° 480 600 TEMP 1 PH 3 PH 1 PH 3 PH 1 PH 1 PH 3 PH 3 PH 3 PH SERIES KW BTU/HR (Deg.F) CFM* 60 HZ 60 HZ 60 HZ 60 HZ 60 HZ 60 HZ 60 HZ 60 HZ 60 HZ ..___________+ --+ 2,0 f85. 10 `6 g 3 3 10,239 98 15 9 13 8 12 9 5 4 4 CU935 4 13,652 111 20 12 17 10 15 12 7 6 5 35 in.(L) 5 17,065 123 250 25 15 22 13 19 15 8 7 6 120 LBS. 6 20,478 136 30 17 26 15 22 18 10 8 7 7 23,891 148 34 20 30 18 26 21 11 9 7 8 27,304 161 39 23 34 20 30 24 13 10 8 4 13,652 85 20 12 18 11 16 13 7 6 6 27,478 98 30 18 26 16 23 18 10 8 7 CU945 27,304 111 40 23 34 20 30 24 13 9 45in.(L) 10 34,130 123 500 48 29 43 25 37 30 16 13 11 160 LBS. 12 ' 6 136 59 34 51 30 44 36 16 13 14 47,78 148 68 40 59 35 52 41 22 18 15 16 54,608 78 46 68 40 59 25 20 17 6 20,478 85 30 18 26 16 23 18 10 8 7 CU958 8 27,304 96 40 23 34 20 24 13 11 9 10 34,130 103 48 29 43 25 37 30 16 13 11 58 in.(L) 12 40,956 111 750 34 51 44 36 19 16 13 200 LBS. 14 47,782 118 68 40 59 35 52 41 22 18 15 16 54,608 128 78 40 59 47 25 20 17 6 20,478 85 31 19 27 16 24 19 11 9 8 9 30,717 98 45 24 34 28 16 13 11 CU968 12 40,956 111 60 35 52 31 45 36 20 16 13 68 in.(L) 15 51,195 123 750 44 64 56 45 25 20 16 260 LBS. 18 61,434 136 88 52 77 45 67 - 29 24 19 21 71,673 148 - 60 89 52 - 34 27 22 24 81,912 161 - 69 - 60 - - 38 31 25 8 27,304 :5 41 24 36 21 31 2 14 12 10 12 40,' 98 60 36 52 31 46 37 0 17 14 CU978 16 •',608 111 79 47 69 41 60 48 2 21 18 78 in.(L) 2t 68,260 123 1,000 - 58 86 50 74 - 33 6 21 300 LBS. 4 81,912 136 - 69 - 60 - - 39 3 25 28 95,564 148 - 80 - 70 - - 45 36 9 32 109,216 161 - 91 - 79 - - - 41 3 NOTE:RED numbers represent circuit breakers or fused disconnect required.**380V units will operate with a 16%reduction in heating capacity.+Based on 60°F inlet air temperature.*Values shown is high speed. FRONT INLET FRO T BOTTOM INLET BOTTOM INLET I"- 35",45',58",68',78' -1 9-3/4" .I FRONT OUTLET(FIFO) TOP OUTLET 0) FRONT OUTLET(BIFO) TOP OUTLET(BITO I7/8 and 3/32" I lIi IIM I concentric K.O. WALL EM 1-23/32%1-23/64"-% 26-3/8" MI �,�I LI I■ and 1-31/32" • - • • • • concentric K.O. 3" t_11l ■I■ 1-1 lin) (' S Mi 1 1 I_ WALL 5" I"-� 1�4,� I t 1 J VERTED L_4-1/4" drill location for conduit hole 1-5/8' in right side .M rig ME o 01111.111111111111111* -„.. .„ ► /'- CEILING • • rr r,+rr 4111111.7 411111.11% Allellir I „,,N, ;4-• 7 ji ON END www.qmarkmep.com 4. For Technical Services, Call 800-642-4328 MARK ITEM#OFLY_CU900_1217-1 A Marley Engineered Products Brand UNIT HEATERS ACCESSORIES CATALOG NO. DESCRIPTION I COMPATIBLE WITH FUNCTION SHIP WT.(LBS) CU935RTK CU935 3 CU945RTK CU945 4 CU958RTK Ceiling or Wall Recess Trim CU958 Provides a neat finish t. i-recessed 5 - or fun reces !. .pplication. CU968RTK CU968 6 CU978RTK illiCU978 7 CU935BK 9 CU945BK CU945 16 gauge,muted black base is recessed from the 10 CU958BK Floor/Toe-Space Base Kit CU958 heater front and sides to provide an attractive and 11 CU968BK CU968 practical floor mounting application. 13 _ CU978BK CU' : 15 CU935AWL 935 5 CU945AWL a CU945 Used on exterior of . . or panel walls of 2-3/4" 6 100%Outside Air, ry CU958AWL Exterior Aluminum Wall Lo CU958 or greater to provi.• . ' ished exterior 7 CU968AWL CU968 For heaters 100%outsi.- •. pers. 9 _ CU978AWL CU978 10 CU935WF CU935 4 CU945WF CU945 6 CU958WF Permanent,Reusable CU958 Replaces standard filter 8 - Washable Filter Washable filter can be cleaned and replaced. CU968W CU968 F CU978 12 OPTIONAL FACTORY-INSTALLED ACCESSORIES ACCESSORY DESCRIPTION Standard -Ear remote-mounted)single-pole,single-stage Thermostat that cycles the element(s)and fan.fan speed and element wattage selected 2-STAGE THERMOSTAT by the built-in HIGH or LOW selector switch. aikt-er Remote Optional Built-in(or remote-mounted)two-stage thermostat that cycles 2/3 of the element for during first stage and full heat during second stage.Fa cycles on high speed only. Standard Control supply is internally generated 24V.Field supplied 24V control supply can be applied to heater.(Requires removing only on•'. per wire 120 ! TROL in the control panel). Internally -••rated Optional 120V internally generated control voltage is available.Field supplied 120V control supply can be applied to heater.(Re. 'es removing only one jumper wire in the control panel.) MANUAL RESET Standard Heater is supplied with auto-reset over temperature cutout. Optional Manual Reset over temperature cutout wired into control circuit.Supplied in addition to auto-reset c . DEAD FRONT dard Supply terminal block in the control compartment. DISCONNECT SWITCH Optiona A three pole non-fused disconnect switch disconnects power to the heater.Design prey••..entry into the control compartment until disconnect witch is turned to the OFF position. DEAD FRONT FUSED Standard Sup. terminal block in the control compartment. DISCONNECT SWITCH' Optional A three po •on-fused disconnect switch and circuit breaker(s)sized • e heater load protects heater and disconnects power to the heater. Design preven . into the control compartment until disconn•- witch is turned to the OFF position. SUMMER FAN SWITCH Standard Fan cycles as the hea . les on and off. Optional Built-in switch provides con i .. s fan operation wit. . without heat,or automatic fan cycling as the heat cycles on and off. ON/OFF SWITCH Standard No switch supplied. Optional Built-in switch provides continuous fan.• :'on with or without heat,or automatic fan cycling as the heat cycles on and off. Standard Two(2)slotted head spring latche KEY LOCK FOR FRONT COVER Optional Two(2)toolhead key locks. spring latches prevent u : horized adjustment of controls and provides additional safety from injury due to contact with internal c.-•orients. NIGHT SET-BACK RELAY Standard Heater will not s .ack at night. 24V or 120V Optional Ability to s0 .ack heater from energy management system that supplies(Sp• -24V or 120V)to relay holding coil for day operation. Standard Ret air only. MOTORIZED 100%OUTSIDE 4V electronically controlled damper with rear mounted duct collar permits outside air t. :•er the chamber at 100%.If power is interrupted at AIR DAMPER* Opti.•. the heater,outside damper remains in the open/closed position from the last switch setting.I....er fully opens in less than 2 minutes when selector switch is in the open damper'position.(Available only with heaters having 24V control su.. Cannot be used with 120V control supply or with bottom inlet configuration) INLET OR DISCHARGE Standard Slotted louver grilles. DUCT COLLAR(S) Optional Collars provide easy connection of field supplied duct work.We do not recommend exceeding 0.2 in.wg external sta .essure.Heater with duct collars are supplied with a single speed high static motor. ARCHIT RAL EXTRUDED Standard Slotted louver grilles. i A UM GRILLES Optional Architectural styled extruded aluminum grille to enhance the appearance of the cabinet unit heater.This option is only available for both i •t and discharge openings ordered at the same time.Can not be ordered separately. NOTE:t Plus price of circuit breaker*Need to add summer fan switch and heat on/off switch.Allow 4 to 6 weeks for shipment with these options. UNIT HEATERS CU900 SERIES CUSTOM CABINET UNIT HEATER HOW TO ORDER CABINET HEATERS—CU900 v f- _ � _ N y w O _ 2 H E.6 - - - H W c u 9 3 5 0 2 2 0 1 FIF B 1R 2 01010 02 : 10 0 0 0 0 A=Architectural Extruded Aluminum Grille Cabinet Unit Heater 0=Standard Louver Grilles I=Inlet Duct Collars/Discharge Louver Grille D=Inlet Louver Grille/Discharge Duct Collar 900 Series i I B=Inlet Duct Collar/Discharge Duct Collar 0=Standard Lock 35=35"Cabinet Length i K=Key Lock 45=45"Cabinet Length 58=58"Cabinet Length 0=Standardized,No Outside Air Damper(must be 0 for bottom inlet) 68=58"Cabinet Length A=Motorized 100%Outside Air Damper 78=78"Cabinet Length 0=Standard Throw-Away Filter P=Permanent"Washable"Filter See Chart(2 kW=02,32 kW=32) 0=Standard,No Night Setback Relay 1=Night Setback Relay(120 Volt Holding Coil) 20=208 Volt Supply Power 2=Night Setback Relay(24 Volt Holding Coil) 24=240 Volt Supply Power 27=277 Volt Supply Power 0=Standard,No ON-OFF Switch 34=347 Volt Supply Power S=ON-OFF Switch 38=380 Volt Supply Power(3-Phase Only) 0=Standard,No Disconnect Switch 48=480 Volt Supply Power(3-Phase Only) 60=600 Volt Supply Power(3-Phase Only) S=Disconnect Switch F=Fused(Circuit Breaker)Disconnect Switch 0=Standard,No Summer Fan Switch 1 =Single Phase Supply Power S=Summer Fan Switch 3=Three Phase Supply Power 0=Standard,No Manual Reset M=Manual Reset F=Front Inlet Air Configuration B=Bottom Inlet Air Configuration 0=No Circuit Breaker(s) C=Circuit Breaker(s),Required or Optional 2=Standard Internal Generated 24 Volt Control F=Front Discharge Air Configuration I 1 =Internal Generated 120 Volt Control B=Bottom Discharge Air Configuration 1B=Standard Single Pole,Single Stage Built-In Thermostat 1R=Single Pole,Single Stage Remote(Wall Thermostat) 2B=Two Stage Built-In Thermostat Series Model Number 2R=Two Stage Remote(Wall Thermostat) 1111 www.gmarkmep.com For Technical Services, Call 800-642-4328 MARK ITEMe QFLY_CU900_1217-1 A Marley Engineered Products Brand (` t- t r t2, ten 4' -14.241111117 CALF T4 i_.. r APEx72 t ..., ., , , ,„I r... b ..., ..„, , . , .. . . , ,,.„,„,,,. ,,,,,i,:e, „,,,, „,,,,- ,,,,,., ..„.....„..„..4,s Bring warmth to your room without sacrificing living space. Our new Apex72 heater is installed high on your wall, so you're free to place furniture where you like, and the heater is Pp out of reach for little hands. The quiet fan efficiently spreads • warmth throughout the entire room. Li ii ARCHITECTURAL-ENGINEERING INFORMATION .L. Fan forced electric air heaters are ETL listed,factory field rated at 120V, 240V and 208V, dual field rated 208V/240V.An orient ring, and a powder coated 20 gauge wall mounting can with six knockouts and 34 cubic inch • Gain up to 9 extra square feet wiring compartment are required. Each complete heater is of unitized of living space with higher construction, is self-contained,and completely separate from the wall placement on the wall mounting can. Element construction is a coiled nichrome heating wire E Contemporary look blends sealed in a steel sheath with steel fins brazed to the sheath. Heating unit seamlessly into any room includes a 16-amp rating at 240V, high temperature manual reset limit • Cover secured by strong magnets, switch.A two stage centrifugal blower is driven by an impedance protected yet detaches easily for cleaning motor.The motor is totally isolated from the heating chamber. Hexagonal • Outlet grille is available or louvered metal outlet grilles are of one piece,constructed of 22-gauge in two designs steel and finished with a powder coat paint system. Decorative, high • Recommended cleaning every impact, high temperature,non-metallic cover attaches with neodymium 24 months, compared with six months for most wall heaters magnets and optional cover screws are available. • Easy to install orient ring assists TECHNICAL INFORMATION in a level,flush installation of wall can UL safety standards require the heater to be placed a minimum distance of Enjoy lasting warmth,thanks to 72 inches from the floor,6 inches(15.2 cm)from adjacent surfaces,and 10 durable sealed heating element inches(25.4 cm)from the ceiling. Maximum distance from bottom of wall can Includes high-temperature safety to floor is 90 inches for ceilings 9 feet and higher. For ceilings greater than 9 shutoff feature feet,a ceiling fan with a cooling thermostat is recommended for optimum performance. Install horizontally only.This heater is not approved for vertical or ceiling installation. Electric wall heaters and thermostats work best when installed on an inside wall.We recommend installing the heater assembly after walls are finished. Heater must be cleaned every 24 months minimum. Specifications are subject to change.©2019 Glen Dimplex Americas. \5 1. (07), I us Glen Dimplex Americas I 1 855 223-3887 I www.cadetheat.com YE"R/ Intertek APEX72 CADETS INVITING WARMTH Cover: 12"W x 8-1/2"H x 1"D • Rough-in: 10"W x 7-7/8"H x 4"D Heater assemblies require orient ring, CC or CCSM wall can,decorative cover and electronic wall thermostat(sold separately) PART MODEL DESCRIPTION WATTS VOLTS AMPS BTUS WT/LBS 65402 HWC101 K Complete unit with orient ring,CC wall can,TH114 120 8.3 65403 HWC102K thermostat,and ACL decorative cover 1000 240 4.2 3415 10.1 65316 HW051 Heater assembly without thermostat 500 120 4.2 1710 4.7 65314 HW101 1000 120 8.3 3415 4.7 65315 H W 151 " 1500 120 12.5 5120 4 7 65305 HW052 " 500 240 2.1 1710 4.7 65304 HW082 " 800 240 3.3 2730 4 7 65303 H W 102 " 1000 240 4.2 3415 4 7 65302 H W 132 " 1300 240 5.4 4440 4 7 65313 HW038 375 208 1.8 1280 4 7 65312 HW058 " 525 208 2.5 1795 4.7 X5311 HW078 .< " 750 0$ (14 4fi0 4.7 65310 HW10e " QTY:(4)TAGS: UH1-3, 1000 208 4.8 3415 47 65309 HW128 . 2-1, 3-1,4-1 1200 208 5.8 4095 4.7 65308 H W 168 " 1600 208 7.7 5460 4.7 65301 HW162 1600/1200 240/208 6.7/5.7 5460/4095 4.7 -6•74363 CC10 \_ Wall can for model HW,single or 10-pack QTY.(4)TAG:HALL CAN -22-S 69110 CCSMB Surface mount wall can for model HW,single,black or white 4.4 69111 CCSMW A ACL t7 Decorative cover for model HW with louver outlet grille,single pack or 5-pack,white } 5 QTY:(4)TAG:GRILLE j 67130 ACH .7 Decorative cover for model HW with hexagonal outlet grille,single pack or 5-pack,white 67132 ACH5 3.6 67051 OR 1.9 Orient ring for model HW,single pack or 10-pack QTY:(4)TAG ORIENT RING }"1"2 Side Decorative Cover Wat Can Side CEILING ------------ :NM....r 1 1 •�e�• 4.45cm ;NO 7.62 cm ����e 10"Minimum PENi����' 7'lr from ceiling .59 20.00 1 •��s• ay; 1i aiN4 D FINIS.... 11/4"�o��r •��M p 3.18cm D 1.-1I. 12" ,I I 10.16cm I +6"Min."h.4 1" 30.48cm 2.54cm Wall Can Bottom ♦ r 11'1, r I* 28.26cm /8'ceiling:bottom of wall can to floor minimum 72" IMF maximum 78" 9'or greater ceiling: bottom of 1'I- wall can to floor alacm minimum 72" l0" maximum 90" 25.4cm Orient Ring O O 0 * 10" O 11 Ye" 25.4 cm 28.26 cm 774' ROUGH-IN:10"W x 7-7/8"H x 4"D 20cm 1 O O I- 17'4" I 44.13cm Q3 2019 QTY:(4) TH106 thermostats for tags UH 1-3, UH 2-1, UH 3-1, and UH 4-1 �„ r TH 1 06 „. 4t, , _ ,. r „.„.',..„-_,..„,-?:,:7,--.,,-. _. Ultimate, programmable control ts," r, i. Save on your heating bill with the TH106 programmable •s digital thermostat. Its precise temperature-sensing control brings comfort to your room with simple programming. Battery-free backup, silent operation, and an early-start function ensure that you're always in control. !'. ', ARCHITECTURAL . ENGINEERING INFORMATION Electronic thermostat is UL listed for USA and Canada. Line voltage Customize your settings, or choose from temperature control shall be digital with LCD display. Switching means pre-programmed options shall be by "triac switching action" to eliminate RF line noise.The • Push-button programming and override control is capable of switching a maximum resistive load of 16.7 amps options with large LCD display that's easy at 240 volts. Minimum load requirement 2 amps. LCD display shall show to read time of day, actual room temperature, mode and current status of the Set for 15 second cycles for baseboard heater. Programming choices are 7-day with 4 daily settings and early heaters, or 5-minute cycles for fan heaters • Controls up to 2,000 watts at 120 volts, start function. Unit shall have a default temperature program of 62°F 4,000 watts at 240 volts or 3,470 watts at (16.5°C).Vented housing shall be white and made of flame retardant 208 volts high impact plastic with two mounting screws provided. No batteries ▪ Ideal performance for electric baseboard shall be required for operation. and wall heaters TECFINICAL INFORMATION , Comfort range: 1 degree Set point range:40°F to 86°F(5°C to 30°C) Device shall have ability to retain programming indefinitely.Time setting must be readjusted if power outage lasts more than 2 hours. Product Dimensions: 16.7 amps maximum load 5"W x 4-15/16"H x 1-1/2"D UPC/PART MODEL DESCRIPTION VOLTS AMPS 027418 08160 5 TH106 Electronic programmable,single pole,retail pack 120/240/208 16.7 CADETt INVITING WARMTH cadetheat.com PPRQIT 855.CADET.US 3l1 ) C U� u Vancouver, Washington \TEAR/ LISTED 02 2016 RCC IES � g�FMR krID® COVE HEATER n A Marley Engineered Products Brand SUBMITTAL SHEET m C 120 us 10/24/19 Date: Red Rock Commons-Tigard n Project: Carleton/Hart Architecture,P.C. m Architect: Fred E.Shaub,Engineer m Engineer: Mill Creek Heating m Contractor: Jacob Buntrock Submitted by: Approved by: HEATERS TAG QTY. CAT. NO. SIZE VOLTS WATTS CUSTOM FEATURES CH-1 48 RCC7508C 59" 208V 750 ACCESSORIES & CONTROLS TAG QTY. CAT. NO. DESCRIPTION CH-1 48 M602W THERMOSTAT ZSS-BRCCO 2-11 www.berkomep.com gl riggB___FRI-c:'__'® W A Marley Engineered Products Brand Q470 Beauty Spot Rd. E,Bennettsville,SC 29512 w Visit: www.berkomep.com for more information I LU ARCHITECT'S AND ENGINEER'S SPECIFICATIONS* OFurnish and install where indicated on the plans,Type RCC Series Cove heaters as manufactured by Berko,A Marley U Engineered Products Brand, Bennettsville, SC. Heaters shall be cULus listed. The heater shall be designed to provide radiant and convection heating in the area to be I heated. Patent Pending. (/) CONSTRUCTION: Uj Front Panel: The front panel which is the radiating surface shall be of extruded aluminum, coated with "high temperature" rated textured powder coat paint to achieve a high radiating efficiency.The backside of the front panel shall have a formed sec- tion to hold the heating element. The backside is to include the crossover wires at the bottom of the extrusion to be able to wire the heater from either end. Back Shield: The back shield shall be formed of 24 gauge plated steel and be able to spring into place without hardware. O The heater shall be open on top and bottom to permit maximum convection heating of room air. lyElement: The heating element wire shall consist of high resistance nickel-chrome alloy wire, embedded in high purity magne- sium oxide and encased in a metal sheath for maximum strength and corrosion resistance. Installation: Mounting brackets shall be included with the heaters for mounting on any wall surface. Heaters shall be com- pletely assembled and pre-wired for either single or multiple-heater installations. Heater construction shall permit supply wiring to be brought in and connected at either end of the heater.All capacities,voltages, physical sizes and options shall be as spec- ified in the heater schedule. SELECTION CHART LENGTH SHIPPING CATALOG NO. WATTS VOLTAGE BTUH AMPS (INCHES) WEIGHT RCC4508C 208V 2.2 34 4 lbs C el US RCC4512C 450W 120V 1536 3.7 34 RCC4524C 240V 1.9 34 RCC6008C 208V 2.9 47 6 lbs RCC6012C 600W 120V 2048 5.0 47 j/���/� 24 �jRCC6024C 240V 2.5 47 RCC6027C 277V 2.2 4727 'RCC7508C 208V X3.6 59 7 lbs RCC7512C 750W 14Bb' 2560 6.2 2) 4"Min. RCC7524C 240V 3.1 JJ / 1 RCC7527C 277V 2.7 53 RCC9008C 208V 4.3 71 8lbs RCC9012C 900W 120V 3072 7.5 71 RCC9024C 240V 3.7 71 11 j/ iffol( / RCC9027C 277V 3.2 71 / RCC10508C 208V 5.0 83 9 lbs / RCC10512C 1050W 120V 3583 8.8 83 / No RCC10524C 240V 4.4 83 RCC10527C 277V 3.8 83 RCC12008C 208V 5.8 94 10 lbs ' J i RCC12012C 1200W 120V 4095 10.0 94 RCC12024C 240V 5.0 94 pp RCC12027C 277V 4.3 94 /� RCC15008C 208V 7.2 118 13 lbs // RCC15024C 1500W 240V 5120 6.2 118 RCC15027C 277V 5.4 118 13/16" -4- RCC18008C 208V 8.7 132 15 lbs RCC18024C 1800W 240V 6142 7.5 132 RCC18027C 277V 6.5 132 RCCT Integral Thermostat:Range 45-90°F will positive off. 1 lb 21/2" RCCSPC Splice Plate Assembly 2 lbs Berko reserves the right to change specifications without prior notice. TOP VIEW 3 CEILING 4"MIN.(DRY WALL CEILINGS) 6"MIN.(LAY IN OR VINYL } 1CEILINGS OR PLASTIC MOLDING) // // /T// // // // /! // // // // // // // // //a// // //( WALL I 1"MIN.BETWEEN BOTTOM 2„ OF HEATER AND ANY FABRIC BACK VIEW I t t CEILING // // !/ // // /! // /! !/ /! // /! // // // // // /! !/ /` _4"MIN.(DRY WALL CEILINGS) / MOUNTING BRACKETS ,ei +I�r ' 6"MIN.(LAY INI OR VINYL CEILINGS 6'MINIMUM E OR PLASTIC MOLDING) CLEARANCE ", IllP '� 4-3116" TO FLOOR w \ 0 �_ f-1-112" MOUNTING SLOTS \\\\\\\\\\ 34'TO 132' FLOOR (0.86 M to 3.35 M) MOUNTING RESTRICTIONS THERMOSTATS & CONTROLS THERMOSTATS I LINE VOLTAGE Qty.(48) for tag CH-1 cove heaters A ,,,...tt2j _ ) , MS26 MD26 MSl14W M602W M601TPW M602TPW M611W M612W ACTION Snap Action Snap Action Snap Action Snap Action TYPE SPST I DPST SPST I DPST SPST 1 DPST SPST 1 DPST WATT RATING Model MD26 has Positive OFF Model M602W has Positive OFF Model M602TPW has Positive OFF Model M612W has Positive OFF 120V 22A 22A 22A 22A 208V 22A 22A 22A 22A 240V 22A 22A 22A 22A 277V 18A 18A 18A 18A PILOT DUTY No Yes 125VA Yes 125VA Yes 125VA TEMP.RANGE °F 50°F to 80°F 45°F to 75°F 45°F to 75°F 45°F to 75°F DIFFERENTIAL +/-5°F '+/- 4°F +/- 4°F +/-2 1/2°F These economy thermostats are the snap action type that These bi-metal snap-action Same as M601 W and M602W Built-in heat anticipator FEATURES are used in apartment construction. thermostats are sensitive. except the cover mounting assures closer control of Good thermostat for its value. Large knob allow for cover offer tamper-proof feature. room temperature. Ideal for radiant cove heaters easy adjustmentP and baseboard. ((fi�ee �L US el. dl•' . @US ®US SP ®US $)° ' 1001000264°P I I z: M600MTP M600S T100 1200 WR651 ACTION Modulation(2-stage) Simultaneous switching(double ckt) Snap Action with Heat Anticipator Creep(Hydraulic)Action TYPE DPST SPST WATT RATING DPST SPST I DPST 120V 22A 22A 22A 22A 208V 22A 22A 22A 22A 240V 22A 22A 22A 22A 277V 18A 18A 18A na PILOT DUTY Yes 125VA Yes 125VA Yes 125VA No TEMP.RANGE °F 50°F to 80°F 50°F to 80°F 50°F to 90°F 40°F to 85°F DIFFERENTIAL Accuracy:Within 3°F of setpoint Accuracy:Within 3°F of setpoint +/-2 1/2°F +/-2°F One thermostat controls two separate Simultaneous control of two heating loads. Line voltage thermostat with everything; Extra-sensitive element in control heating circuits and reduces input during Used where the total load slightly exceeds Performance,reliability,durability,and knob senses radiant heat as well FEATURES light load periods.Second stage activates capacity of a single switch,where two a large knob.Built-in heat anticipation as air temperature for ultimate when temperature drops to approx. thermostats are impractical.Both switches assures close temperature regulation. control.May cause slight radio or 1-1/2°F below the first stage tum-ON are calibrated to operate at approx.the Large knob for easy rotation. television interference in outlying temperature. same temperature. fringe areas. UL US a ®US ei. UL US SA' uL US SA" For the latest models and information,please visit our website at www.berkomep.com 5 ilSUBMITTAL SHEET E MARK® MUH SERIES = A Marley Engineered Products Brand \ HORIZONTAL/VERTICAL T vaillill UNIT HEATERS �o rn �� imm � I C ® US I File#E21609 XI N `� Z n JOB NAME: LOCATION: m M ARCHITECT: -I ENGINEER: n a CONTRACTOR: r SUBMITTED BY• C Z DATE: I m CATALOG GRILLE CEILING D ITEM QTY. NUMBER TAG WATTS VOLTS 0 AMPS FINISH MOUNT ' 1 • m 1 1 MUH0381 UH 1-2 3KW 208 1 14.5 W M 2 1 MUH0381 UH B-1 3KW 208 1 14.5 W N 3 1 MUH0381 UH B-2 3KW 208 1 14.5 W ITEM QTY. s CAT. NO. TAG DESCRIPTION 1 3 B10 UH I-2,UH B-1,2 MOUNTING BRACKET ACCESSORIES 2 3 UHMTI UH 1-2,UH B-1,2 THERMOSTAT AND CONTROLS SUBMITTED BY: DATE APPROVED BY: DATE ZSS-QMUHO 06-17 H W CC MARK® ILI .2-speed fan selector switch(25 to 50 KW models). Cl) AMarley Engineered Preclude Brand . Fan delay feature eliminates cold drafts.Element heats up Cvisit www.qmarkmep.com for more Info C ARCHITECT'S AND ENGINEER'S SPECIFICATIONS* after element shuts off. • Ruggedly built,yet lighter weight for easier installation.No •Unit mounts either horizontally or vertically.Totally versatile.For factories, piping flutes,valves,or traps. warehouses,garages,stores,shipping rooms,power stations.Can be used for . Individually adjustable discharge louvers to control air flow. primary,supplementary,spot,or dual-system heating. •Choice of optional diffusers for variety of air patterns, •Wide range of optional control kits are field installable,increasing the MUH maximizing heat concentration and coverage in the vertical adaptability to the specification market. position. • Forced air unit heater with 10 power ratings;from 3KW to 50 KW heating output; 208,240,277 and 48OV,10,230 to 170,500 BTU/hr. • Meets all UL,NEC,and OSHA requirements. •32 compatible models(no need to try to assemble a heating system from 70 or 80 models!) , .,?'-ie •Heavy gauge die formed steel housing.Two toned,smartly styled with stainless steel louvers. •Advanced pull-through air flow design draws air across heating element for more �' '��- even air distribution and cooler element operation. jH •Specially designed venturi outlet to meet that added throw as required in vertical \ position. • Branch circuit fusing(when required). •Completely enclosed fan motor. ,� • 1-or 3-phase wiring on 5 through 10 KW 2O8/24OV and 15 KW 2O8V units(field �� interchangeable). •Aluminum-finned,copper clad steel sheath heating element has longer useful ND \ /w life,because of cooler sheath temperature and faster heat dissipation. DIMENSIONS ~ •24V control transformer standard on most models,providing a safer and more CAT.NO. I HEIGHT I WIDTH I DEPTH accurate means of temperature control.3KW and 5KW,208-277V,have line MUH-03&05 16" 14" 71//" voltage controls as standard(24V control available on made-to-order basis). MUH-07&10 21314" 19" 71R" •Automatic reset linear thermal cut-out,capillary type,provides protection over MUH-15&20 213/4" 19" 123/4" entire length of element areas(Manual reset protection available on made-to- MUH-25&30 30" 266/3' 113/4 order basis). MUH-40&50 30" 266/8" 171/8" SELECTION CHART ELECTRICAL DATA 2 STAGE AIR DELIVERY DATA FAN MOTOR DATA MAXIMUM EFFECTIVE LORI. INSTALLED CONTROL ELEMENT MOUNTING HEIGHT WEIGHT CAT.NO. VOLTS PHASE SW BTVA�R. AIR WIRE (L95) Gpp I AMPS(3) VOLT U) CONTROL I CFM(2) 1 FPM(2) I ATM I VOLTS 1 RPM(2) I HP I HORIZ. I VERT. ITHROWI SIZE w43846K. MUHD34E '208 10 3.0 102 14.5 208 N/A 350 800 27° 208 1600 1/100 8 12 AWG 12 27 MUH03-21 208/240 10 2.2/3.0 7.5710.2 11.0/12.5 208/240 N/A 350 800 27° 208/240 1600 1/100 9 12 AW(.12 27 MUH03.71 277 10 3.0 10.2 11.0 277 N/A 350 800 27° 277 1600 1/100 9 12 AWG 14 27 MUH03-31 347 10 3.0 10.2 8.6 24 N/A 350 800 27° 347 1600 1/100 9 12 AWG 14 27 MUH0341 480 30 3.0 10.2 3.6 24 N/A 350 800 27° 480 1600 1/100 9 12 AWG 14 27 MUH03-61 600 30 3.0 10.2 2.9 24 N/A 350 800 27° 600 1600 1/100 9 12 AWG 14 27 MUH05.81 208 1-30 5.0 17.0 24.0 208 SA 350 800 45° 208 1600 1/100 9 12 AWG10 27 MUH05-21 208/240 1-30 3.7/5.0 12.6/17.0 18.021.0 208/240 5A 350 800 45° 256,240 1600 1/100 9 12 AWG 10 27 MUHO5-71 277 10 5.0 17.0 18.0 277 N/A 350 800 45° 277 1600 1/100 9 12 AWG10 27 MUH05.31 347 10 5.0 17.0 14.4 24 N/A 350 800 45° 347 1600 1/100 9 12 AWG 10 27 MUH05.41 480 30 5.0 17.0 6.0 24 N/A 350 800 45° 480 1600 1/100 9 12 AWG 14 27 MUH05.61 600 30 5.0 17.0 4.8 24 N/A 350 800 45° 600 1600 1/100 9 12 AWG 10 27 MUH-07-8 208 1.30 7.5 25.6 36.0 24 5B 650 970 37° 208 1600 1430 9 14 18 AWG 6 38 MUH-07-2 208240 1.30 5.6/7.5 19.1/25.6 27.0/31.3 24 58 650 970 37° 208240 1600 1/30 9 14 18 AWG 8 38 141114-07-7 277 10 7.5 25.6 27.0 24 58 650 970 37° 277 1600 1/30 9 14 18 AWG8 38 MU11-07.4 347 10 7.5 25.6 21.6 24 5B 650 970 37° 347 1600 1/30 9 14 18 AWG 14 38 MU1407-4 480 30 7.5 25.6 9.0 24 58 650 970 37* 480 1600 1/30 9 14 18 AWG 14 38 MUH-07. 600 30 7.5 25.6 7.3 24 5B 650 970 37° 600 1600 1/30 9 14 18 AWG 14 38 MUH-18.8 208 1-30 10.0 34.1 48.0 24 5B 650 970 49° 208 1600 1/30 9 14 18 AWG 4 38 MUH-18.2 208/240 1-30 7.5/10.0 25.6/34.1 36.0/42.0 24 5B 650 970 49° 208240 1600 1/30 9 14 18 AWG 6 38 MUFL10.7 277 10 10.0 34.1 36.0 24 5B 650 970 49° 277 1600 1/30 9 14 18 AWG 6 38 MUH-103 347 10 10.0 34.1 28.8 24 5B 650 970 49° 347 1600 1430 9 14 18 AWG 14 38 MUH-10.4 480 30 10.0 34.1 120 24 5B 650 970 49* 480 1600 1/30 9 14 18 AWG 14 38 MUH-10.6 600 30 10.0 34.1 9.7 24 58 650 970 49° 600 1600 1/30 9 14 18 AWG 14 38 MUH-15-8 208 1-30 15.0 51.2 72.0 24 5A 910 1640 52° 208 1530 1/20 11 20 35 AWG 2 53 MUH-15.2 208/240 30 11.2/15.0 38.2/51.2 31.3/36.1 24 SC 910 1640 52° 208/240 1530 1/20 11 20 35 AWG 6 53 MUH-153 480 30 15.0 51.2 18.0 24 5C 910 1640 52° 480 1530 120 11 20 35 AWG 10 53 114UH-15-6 600 30 15.0 51.2 14.5 24 5C 910 1640 52° 600 1530 120 11 20 35 AWG 12 53 MUH-20-8 208 30 20.0 68.2 56.0 24 5A 1320 2060 48° 208 1500 1/10 12 23 41 AWG 4 60 MUH-20.2 208/240 30 15.0/20.0 51.2/682 41.2/48.0 24 5C 1320 2060 48° 208240 1500 1/10 12 23 41 AWG 4 60 MUH-20-4 480 30 20.0 68.2 24.0 24 5C 1320 2060 48° 480 1500 1/10 12 23 41 AWG 10 60 MUH-204 600 30 20.0 68.2 19.3 24 5C 1320 2060 48° 600 1500 1/10 12 23 41 AWG 12 60 MUH-25-2 208240 30 18.725.0 63.8/85.2 52.0/60.0 24 5A 2100/1800 2100/2030 38 144° 208/240 1600/1375 1/4 13 23 50 AWG 3 93 MUH-254 480 30 25.0 85.2 30.0 24 SC 2100/1800 2100/2030 38°/44° 480 1600/1375 1/4 13 23 50 AWG8 93 MUH-25-6 600 30 25.0 85.2 24.2 24 5C 2100/1800 2100/2030 38./44° 600 1600/1375 1/4 13 23 50 AWG 10 93 MUH30.8 208 30 30.0 102.3 84.0 24 5A 2100/1800 21002030 45°/53° 208 1600/1375 1/4 12 20 50 AWG 1 93 MUH-304 208240 30 22.5/30.0 76.7/102.3 63.0/72.3 24 5A 2100/1800 2100/2030 45 053° 208240 1600/1375 1/4 12 20 50 AWG 2 93 MUH304 480 30 30.0 102.3 36.0 24 5C 2100/1800 2100/2030 45 053° 480 1600/1375 1/4 12 20 50 AWG 6 93 MUH39.6 600 30 30.0 102.3 29.0 24 5C 2100/1800 2100/2030 45°/53° 600 1600/1375 1/4 12 20 50 AWG 8 93 MUH40.2 208240 30 30.0/40.0 102.3/136.4 83.4/36.4 24 5A 3000/2600 32602900 42 049° 208240 1525/1420 1/2 15 28 60 AWG 1/0 114 MUH404 480 30 40.0 136.4 48.0 24 5A 30002600 3260/2900 42149° 480 1525/1420 1/2 15 28 60 AWG 4 114 MUH40'6 600 30 40.0 136.4 38.7 24 5A 3000/2600 3260/2900 42 049° 600 1525/1420 12 15 28 60 AWG 6 114 MUH-604 208 30 50.0 170.5 139.0 24 5A 3000/2600 3260/2900 53 061° 208 1525/1420 1/2 15 25 60 AWG 4/0 114 MUH-50-2 208240 30 37.5/50.0 127.3/170.5 104.2/120.4 24 5A 3000/2600 3260/2900 53 061° 208/240 1525/1420 1/2 15 25 60 'AWG 3/0 114 MUH-50-4 480 30 50.0 170.5 60.2 24 5A 3000/2600 3260/2900 53 061° 480 1525/1420 1/2 15 25 60 AWG 4 114 MUH-50.6 600 30 50.0 170.5 48.3 24 5A 30002600 3260/2900 53 061° 600 1625/1420 1/2 15 25 60 AWG 3 114 Note: 1. All standard units are supplied with a low voltage control transformer and contactor(24V)except 3. On dual phase units,maximum amp draw is listed for respective voltage. MU11-03&05,208,240&277 volt models.Low voltage control on these units are available on made 4. 25 thru 50 KW models have two speed motors and dual CFM ratings. to order.All units are also available on special order for 120 volt control;internal and transformer or 5A. Standard. external without transformer. 5B.Optional-made to order-amp load unbalanced on 3 Phase. 2. On dual voltage units;CFM,FPM,and RPM are shown at higher voltage. 5C.Optional-made to order-amp load balanced on 3 Phase. MUH SERIES UNIT HEATER DIMENSIONS w -1- D 1 CATALOG NO. HEIGHT(IN) WIDTH(IN) I DEPTH(IN) MUH03&05 16 14 7-1/2 \--------J MUH07&10 21-3/4 19 7-1/2 --- ---•l MUH15&20 21-3/4 19 12-3/4 MUH25&30 30 26-5/8 11-3/4 ;o ) i MUH40&50 30 26-5/8 17-1/8 J 1---!1/ OPTIONAL FIELD-INSTALLED CONTROLS CATALOG NO. UPC DESCRIPTION ELECTRICAL RATING COMPATIBLE WITH 'Single Pole Internal Thermostat-Temp > „ o i;' ',. UHMTt $$360 15241 77. All MUH Series Heaters Ran r°-: °F -,277VA a= 1,J:(41 L)ifsP 1 3 PH M 1-10581 PH which •e HMT2` Two Stage Internal Thermostat-Temp 25A @ 120,240VAC Res. MUH0521 3 PH,MUH0581 3 PH,MUH158,MUH2O8,MUH252,MUH302, UHMT2 6 85360 15242 4 Range:40°-85°F 22A @ 277VAC Res.125VA MUH308,MUH402,MUH404,MUH406,MUH502,MUH504,MUH506, MUH508 MCFS 6 85360 04637 2 Internal Summer Fan Switch 250,480, Pilot Duty 6A,600VAC Res.2 HP All MUH Series Heaters 600V.A.C.1,2 OR 3 PH MRFS1 6 85360 04708 9 Remote Summer Fan Switch(Line 2 HP,250-480VAC All MUH Series Heaters Voltage) MRFS2 6 85360 04709 6 Remote Summer Fan Switch with Relay 6 AR,35 ALR,250VAC,60Hz All MUH Series Heaters(except MUH0321,MUH0371,MUH0381,MUH0521, (24V Coil-Sin.le Pole Normally Open) 3 AFL,18 ALR,480VAC,60Hz MUH0571,MUH0581)Units unless optional control transformer is sup.lied Heat Recovery Thermostat with Relay 6 AFL,35 ALR,250VAC,60Hz All MUH Series Heaters(except MUH0321,MUH0371,MUH0381,MUH0521, MHRT 6 85360 04694 5 (24V Coil-Single Pole Normally Open)Hi- 3 AFL,18 ALR,480VAC,60Hz MUH0571,MUH0581)Units unless optional control transformer is supplied 120°F,Low-60°F p pp MUH0321,MUH0341,MUH0371,MUH0381,MUH0521,MUH0541,MUH0571, MPDS25 6 85360 04703 4 Power Disconnect Switch(3-Pole) 30A @ 600VAC,Res. MUH0581,MUH073,MUH074,MUH076,MUH104,MUH106,MUH154, MUH156,MUH2O4,MUH2O6 MUH072,MUH077,MUH078,MUH102,MUH103,MUH107,MUH108, MPDS60 6 85360 04704 1 Power Disconnect Switch(3-Pole) 80A @ 600VAC,Res. MUH152,MUH2O2,MUH2O8,MUH252,MUH254,MUH256,MUH304, MUH306,MUH404,MUH406,MUH504,MUH506 NOTE:Any field installed options assembled in the factory require added surcharge.See price book for charges.MPDS60 disconnect switch is not suitable for field installation on 7.5kw and 10kw unit heaters. DIFFUSER SELECTOR TABLES FOR VERTICAL MOUNTING MAX. CATALOG MOUNTING NO. DESCRIPTION CATALOG NO. HEIGHT (A)DIMENSION DIFFUSER PATTERN AND AREA NONE MUH03&MUH05 18 26 NONE MUH07&MUNI 0 NONE WITHOUT DIFFUSER MUH15 20 f I NONE No diffuser needed where a straight downflow MUH2O P3 35 40 air pattern is required.For maximum air throw, 11 1111111111111 NONE MUH25 23 NONE remove louvers.Any of three diffusers can be 63 55 1 I added to basic heater. MUH30 20 NONE MUH40 28 70 63 NONE MUH50 25 MLDS MUH03&MUH05 9 25(A) 12(B) MLDM MUH07&MUH10 14 39(A 19(B) - MLDM LOUVER DIFFUSER MUH15 18 50(A) 25(B) MLDM Permits directional(straight line)air flow as in air MUH2O 20 56(A) 28(B) •IIIIIIIIIIIIIII curtain application over doorways.Rectangular MLDL coverage,Louvers can be turned in either direc- MUH25 23 72(A) 36(B) sinomm al, MLDL tion. MUH30 20 MLDL MUH40 24 88(A) 44(B) MLDL MUH50 22 80(A) 40(B) MUH SERIES UNIT HEATER OPTIONAL MOUNTING BRACKETS BRACKET SIZE CATALOG NO. ( UPC I COMPATIBLE WITH I SHIP WT.(LBS) DIMENSION A I 3-20 kW(IN.) 25-50 kW(IN.) 9-7/16 P A^ 04 Ma4.1Q 0 B 9-1/2 14-3/8 620 6 85360 15230 1 MUH15&20 10 C 7-1/4 12-1/8 B30 6 85360 15231 8 MUH25&30 13 D 11-5/16 2-1/16 E 2-1/4 3 B50 6 85360 15232 5 MUH40&50 15 L 20-1/2 28-15/16 M 9-15/16 14-15/16 N 3-1/4 4-1/2 OPTIONAL CEILING MOUNTING BRACKETS 1-1 CATALOG NO. I UPC COMPATIBLE WITH I SHIP WT.(LBS) Ell CMB70 6 85360 15236 3 MUH03-10 3 I=1 CMB20 6 85360 15237 0 MUH15&20 4 CMB30 6 85360 15238 7 MUH25&30 5 CMB50 6 85360 15239 4 MUH40&50 6 , 111= 1" OPTIONAL VERTICAL CEILING MOUNTING BRACKETS CATALOG NO. I UPC I COMPATIBLE WITH I SHIP WT.(LBS) VDMB5 6 85360 15245 5 MUH03-05 5 VDMB20 6 85360 15246 2 MUH07-20 7 VDMB50 6 85360 15247 9 MUH25-50 9 MOUNTING LIMITATIONS:Unit heaters should not be used in potentially explosive atmospheres.The finish is not intended for direct salt spray exposure in marine applications or the highly corrosive atmospheres of swimming pools,chemical storage bins, etc.Do not install unit heaters above recommended maximum mounting height.Obstructions must not block unit heater air inlet E or discharge.Heaters must be mounted at least 7 ft.above the floor to prevent accidental contact with the heating element or fan blade which could cause injury. A � FACTORY-INSTALLED OPTIONS FOR CONTROLS&ACCESSORIES 1-1/2" B \ > SNIS4'-':). . DESCRIPTION MUH03&05(208,208/240,277V Supply) 24 or 120V Control Transformer and Power Contactor D 24 or 120V H.C.Power Contactor \ MUH03&05(480V Supply)&MUH07 thru MUH50 ----1 Optional 120V Control N C 2-Stage Control of Elements(See Note 5) ManualResetReset Outlet Mesh(Bird Screen)For all MUH Heaters .'' 3/a" NOTE:Any factory-installed options require added surcharge.See price book for charges or contact factory. 1-1/2" c '') JOHNSON AIR PRODUCTS 'Ilir \\N. -----7-,Z. _- ri--_----__::----- ---- --- SUBMITTAL Fans and Vents by Greenheck Project: Red Rock - Tigard Project Address: 11090 SW 68th Pkwy Tigard, OR 97223 Architect: Carleton/Hart Architecture, P.C. Engineer: Fred E. Shaub, Engineer General Contractor: LMC Construction Mechanical Contractor: Mill Creek Heating Date: 10/24/2019 Project: Red Rock - Tigard Project ID: P18-0988 JOHNSON AIR PRODUCTS Table of Contents Tab Submittal Spec/Sub Page# 1 Fans and Vents by Greenheck M0.02 Fans (GH)- Submittals- Red Rock 4 Project: Red Rock - Tigard Project ID: P18-0988 ISH SON AIR PRODUCTS Spec Section: M0.02 Fan Schedule Submittal Name .Y U a) Fans and Vents by Greenheck /Ln Vendor/Subcontractor Johnson Air Products U_ 13GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value In Air. Mark: EF 1-4 Model: SQ-70-VG Model: SQ-70-VG Direct Drive Centrifugal Inline Fan Dimensional Quantity 1 Weight w/o Acc's(Ib) 30 Weight w/Acc's(Ib) 37 0.8 .• _ 0.40 • 0.7 0• .35 Performance • Requested Volume(CFM) 185 0.6 - t -' —--- - 0.30 Actual Volume(CFM) 177 77 Total External SP(in.wg) 0.364 3 0.5 �s ,RpM 0.25 ,. Fan RPM 1725 W s Operating Power(hp) 0.04 w 0.4 v __.. , - ,/ — 0.20 014 3 Elevation(ft) 108 a Airstream Temp.(F) 70 n` 0.3 ., — -/- ---- --- 1 — 0.15 Y Air Density(Ib/ft3) 0.075o -- m Tip Speed(ft/min) 3,669 U) 0.2 - -- =— — 0.10 • Static Eff.(%) 25 r • 0.1 — 0.05 -1 0.0 -L-j-1- I i 1 I HI i " ' HIill ' HI l 0.00 0 40 80 120 160 200 240 280 320 360 Motor Volume(CFM) Motor Mounted Yes Size(hp) 1/15 Voltage/Cycle/Phase 115/60/1 A Operating Bhp point Static Pressure Calculations Enclosure TENV 0 FOaperating n curve point at Total External SP External SP 0.4 in.wg Motor RPM 1725 ---•---System curve Direct Drive RPM Adjustment -0.036 in.wg Windings 1 Brake horsepower curve Total External SP 0.364 in.wg Notes: All dimensions shown are in units of in. 'NEC FLA-based on tables 430.248 or 430.250 of Qmca Sound Power by Octave Band National Electrical Code 2014.Actual motor FLA may vary, IMMOUPIDE coarrfor sizing thermal overload,consult factory. Atoos D Sound LwA-A weighted sound power level,based on ANSI S1.4 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones Data dBA-A weighted sound pressure level,based on 11.5 dB fOUAD attenuation per Octave band at 5 ft-dBA levels are not Me Inlet 68 70 69 54 50 49 44 38 63 51 6.0 licensed by AMCA International �uvoNueRe Radiated 67 66 59 45 39 30 25 25 54 43 3.0 Sones-calculated using AMCA 301 at 5 ftZVEITini w nnl,COM. 'ac n Fr jlnn Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 1 of 38 [jGREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: EF 1-4 Model: SQ-70-VG Model: SQ-70-VG Direct Drive Centrifugal Inline Fan Standard Construction Features: -Galvanized steel housing-Backward inclined composite(sizes 60-95)or aluminum(sizes 97-160)wheel-Two bolted access panels-Integral duct connection flanges-Ball bearing motors(sizes 97-160 and all vari-green motors), sleeve bearing motors(sizes 60-95)-Corrosion resistant fasteners Selected Options &Accessories: Motor-Vari-Green EC motor with Dial ONLY(Not capable for field conversion to 0-10) Control-Vari-Green Dial on Exterior of Fan Housing,Mounted and Wired UL/cUL 705 Listed-"Power Ventilators" Switch,NEMA-1,Toggle,Shipped with Unit Junction Box Mounted&Wired Composite Wheel Material Insulated Housing-1 in.Thick:Fan Housing Isolator Mounting Brackets(PN 800201)(Shipped Loose) Unit Warranty: 1 Yr(Standard) Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 2 of 38 1 GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: EF 1-4 Model: SQ-70-VG SQ-70-VG Direct Drive Centrifugal Inline Fan 15.75 /?) c IIum ■m 10.80 �I• ■NO IIIIM3: etet c TOP VIEW 8.881 SQ. INLET 12.00 11 1I ' _ \L l --.-12.00-.— 1.50 i --.-13.00i —1.50 16.00-- END VIEW SIDE VIEW Notes:All dimensions shown are in units of in. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 3 of 38 I GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: EF 1-4 Model: SQ-70-VG Disconnect Switch Enclosure Rating: NEMA-1 Standard Construction Features: Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor corrosion protection design tests. The rod entry test is intended to simulate incidental contact with enclosure equipment. Enclosure is equipped with provision to lockout in the off position with customer supplied lock. Disconnect Switch Configuration Type: Toggle Motor Size: 1/15 hp Voltage: 115 UL Listed: Yes Manufacturer: Pass and Seymour Cycle: 60 Amperage: 15 CSA Approved: Yes Overload Protection: None Phase: 1 Switch Pole(s): 1 Rating: 1/2 hp Junction Box Mtg.: Mounted and Wired RPM: 1725 Exp. Resist. Wiring: None Switch Mounting: Shipped With Unit Electrical Drawing Details 00.28 (4 HOLES) Wiring Schematic O 4.35 • O 1.06 • O 1.65 0 1 ` � 0 0.72 — L 2.00 1.06 2.50 Notes:All dimensions shown are in units of in. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 4 of 38 IBGREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: EF 1-4 Model: SQ-70-VG Assembly Drawing Type: Direct Drive Centrifugal Inline Fan 15.75 al. ■Ili 10.80 MN IND IIIIII k 0 r c TOP VIEW 8.88 SQ. INLET 12.00 I I —12.00— 1.50-- —13.00-- --1.50 — 16.00 END VIEW SIDE VIEW Notes:All dimensions shown are in units of in.. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 5 of 38 j GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: EF 1-4 Model: SQ-70-VG Vari-Green Motor & Control Options An EC motor that uses AC input power and internally converts it to DC power. Motor accepts a 0-10VDC control signal along with a 24V source to power controls in the motor. Motor is operable in the 2-10VDC range and off while in the 0-1.9VDC range. Vari-Green motors feature a soft-start and inherent thermal and current protection built into each unit. Inrush current at start up is eliminated and the motor will automatically reduce speed or turn off if overloaded or it becomes too hot. An EC motor that uses AC input power and internally converts it to DC power. Potentiometer(dial) mounted on the fan housing adjusts the speed (RPM) down 80%. Vari-Green motors feature a soft-start and inherent thermal and current protection built into each unit. Inrush current at start up is eliminated and the motor will automatically reduce speed or turn off if overloaded or it becomes too hot. Motor Configuration Varl-Green Input Voltage: 115 Speed Reference: 0-10VDC 24V Required: No FACTORY WIRING Permanent Dial: No FIELD WIRING Balance Dial Included: N/A vVAN-GREEN. Wier / (FACTORY MOUNTED 4 S 6 \ \ Control Configuration SPEED co! RDL VOLTAGE 3 O O 2� -e o PRESENT I Control Type: Dial on Fan NRS 2E.AC 0 10 J/ 'NOTE \ JTPUT: 24vOC,o-tOVDC I I J / / BLACK WIRE NOT USED COM 24V10-1U� Transformer: Included /� oN SOME MOTORS _SGS 33 r F1V IC 11 \\� 2X4 JUNCTION BOX DRAWING INPUT VOLTAGE —— —— 1.2.v2 --- -- -- -- — Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 6 of 38 LHGREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: EF 1-4 Model: SQ-70-VG SQ-70-VG Min/Max Fan Curve Performance Requested Actual Total External Fan Operating Volume Volume SP(in.wg) RPM Power(hp) (CFM) (CFM) 185 177 0.364 1725 0.04 0.8 0.40 0.7 - -- ,` . 1035 1i. 0.6 - - — - 0.30 • cr) 172 •��0.5 - - -' - _ - 0.25 ,..7.- a) � F�pM •f - 20.4 -- � ' 0.203 a) _ o co i 2 0.3 - `'. ' --- - 0.15 ami U -- Co �.-, . co cin r 0.2 - - - -- - - - 0.10 0.1 c P Mx•:•_FRPM- ---- -• __ 0.05 302 F PM• - 0.0 - I 1 1 I 1 1 l 1 1 h 0.00 0 40 80 120 160 200 240 280 320 360 Volume (CFM) A Operating Bhp point 0 Operating point at Total External SP Fan curve - - - -System curve Brake horsepower curve Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 7 of 38 GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: EF 1-4 Model: SQ-70-VG AMCA amca WORLDWIDE CERTIFIED RATIAGS SOURD ano RIR PERIORMAACE RIR n ovcrnEnT 4i Rnn COOTROI •°�� nssocinTiOn 9*o�� InTERnnTIOnnl. inc. AMCA Licensed for Sound and Air Performance. Power rating (BHP/kW)does not include transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP/kW)does not include transmission losses. Performance ratings do not include the effects of appurtenances(accessories). The inlet sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type B: free inlet hemispherical sone levels. dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies to inlet sone ratings only. Radiated (casing)sound data is the sound generated through the fan housing when the fan is ducted on both the inlet and outlet. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 8 of 38 aiGREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: EF B-1 Model: SQ-80-VG Model: SQ-80-VG Direct Drive Centrifugal Inline Fan Dimensional Quantity 1 Weight w/o Acc's(Ib) 46 Weight w/Acc's(Ib) 53 0.7 0.7 1582 p,o •0.6 -_ — 0.6 Performance - Requested Volume(CFM) 280 Actual Volume(CFM) 280 0.5 - • 0.5 Total External SP(in.wg) 0.4 3 / ^ Fan RPM 1582 -- 0.4 d 0.4 . Operating Power(hp) 0.06 m z' ' 43 Elevation(ft) 108 12 0.3 ---- — '-, -- 0.3 ti Airstream Temp.(F) 70 p`- .�' Y Air Density(Ib/ft3) 0.075 g 0.2 �, 0 2 m o m Tip Speed(ft/min) 4,504 CO Static Eff.(%) 30 0.1 --'� 0.0 ,,L.1-- , III ! I l l l l r i. 1 . 1 . . 1 . . , i t SII 0.0 0 50 100 150 200 250 300 350 400 450 500 Motor Volume(CFM) Motor Mounted Yes Size(hp) 1/10 Voltage/Cycle/Phase 115/60/1 G Operating Bhp point Enclosure TENV 0 Operating point at Total External SP Fan curve Motor RPM 1725 ---••- -System curve Windings 1 Brake horsepower curve Notes: All dimensions shown are in units of in. *NEC FLA-based on tables 430.248 or 430.250 of lama Sound Power by Octave Band National Electrical Code 2014.Actual motor FLA may vary, EIOltunliDE caninfor sizing thermal overload,consult factory. RATINGS r Sound LwA-A weighted sound power level,based on ANSI S1.4 RATINGS 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones Data dBA-A weighted sound pressure level,based on 11.5 d6 MUM attenuation per and atInlet 68 74 69 62 60 58 53 47 67 55 7.6 licensed by AMCOAtave lnternational ft-dBA levels are not D rluou�R Radiated 67 69 59 52 49 39 34 34 57 46 4.1 Sones-calculated using AMCA 301 at 5 ft Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 9 of 38 LSGREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: EF B-1 Model: SQ-80-VG Model: SQ-80-VG Direct Drive Centrifugal Inline Fan Standard Construction Features: -Galvanized steel housing-Backward inclined composite(sizes 60-95)or aluminum(sizes 97-160)wheel-Two bolted access panels-Integral duct connection flanges-Ball bearing motors(sizes 97-160 and all vari-green motors), sleeve bearing motors(sizes 60-95)-Corrosion resistant fasteners Selected Options &Accessories: Motor-Vari-Green EC motor Control-Vari-Green Dial on Exterior of Fan Housing,Mounted and Wired UL/cUL 705 Listed-"Power Ventilators" Switch,NEMA-1,Toggle,Shipped with Unit Junction Box Mounted&Wired Composite Wheel Material Insulated Housing-1 in.Thick:Fan Housing Motor Cover Isolator Mounting Brackets(PN 800201)(Shipped Loose) Unit Warranty: 1 Yr(Standard) Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 10 of 38 L'GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: EF B-1 Model: SQ-80-VG SQ-80-VG Direct Drive Centrifugal Inline Fan 18.75 MCI 13.80 I CNN MCI TOP VIEW f 1 11.88SQ. INLET 15.00 11 , i I I \L J —15.00-- 1.50— --16.00 —1.50 — 19.00 END VIEW SIDE VIEW Notes:All dimensions shown are in units of in. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 11 of 38 INGREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: EF B-1 Model: SQ-80-VG Disconnect Switch Enclosure Rating: NEMA-1 Standard Construction Features: Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor corrosion protection design tests. The rod entry test is intended to simulate incidental contact with enclosure equipment. Enclosure is equipped with provision to lockout in the off position with customer supplied lock. Disconnect Switch Configuration Type: Toggle Motor Size: 1/10 hp Voltage: 115 UL Listed: Yes Manufacturer: Pass and Seymour Cycle: 60 Amperage: 15 CSA Approved: Yes Overload Protection: None Phase: 1 Switch Pole(s): 1 Rating: 1/2 hp Junction Box Mtg.: Mounted and Wired RPM: 1725 Exp. Resist.Wiring: None Switch Mounting: Shipped With Unit Electrical Drawing Details 00.28 (4 HOLES) Wiring Schematic O 4.35 • O 1.06 • • Q 1.65 O 41 0.72 — 2.00 ui- 1.06 2.50 — Notes:All dimensions shown are in units of in. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 12 of 38 GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: EF B-1 Model: SQ-80-VG Assembly Drawing Type: Direct Drive Centrifugal Inline Fan 18.75 �■ Imo 13.80 1---- /3\ 0 TOP VIEW 11.88 SQ. INLET 15.00 I I I � I i _ 11 \LJ 15.00 1.50-- —16.00 — 19.00 — END VIEW SIDE VIEW Notes:AU dimensions shown are in units of in.. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 13 of 38 Printed Date: 10/14/2019 tbr,GREENHECK Job: Red Rock Commons Building Value in Air. Mark: EF B-1 Model: SQ-80-VG Vari-Green Motor & Control Options An EC motor that uses AC input power and internally converts it to DC power. Motor accepts a 0-10VDC control signal along with a 24V source to power controls in the motor. Motor is operable in the 2-10VDC range and off while in the 0-1.9VDC range. Vari-Green motors feature a soft-start and inherent thermal and current protection built into each unit. Inrush current at start up is eliminated and the motor will automatically reduce speed or turn off if overloaded or it becomes too hot. An EC motor that uses AC input power and internally converts it to DC power. Potentiometer(dial) mounted on the fan housing adjusts the speed (RPM)down 80%. Vari-Green motors feature a soft-start and inherent thermal and current protection built into each unit. Inrush current at start up is eliminated and the motor will automatically reduce speed or turn off if overloaded or it becomes too hot. Motor Configuration Vari-Green Input Voltage: 115 Speed Reference: 0-10VDC 24V Required: No FACTORY WIRING Permanent Dial: No FIELD WIR.NG r Balance Dial Included: N/A v �E ar / FACTORY MOUNTED 4 S \ SPEED CONTROL 7 Control Configuration VOLTAGE PRE ENT 21 /"--1 ..b (, f Control Type: Dial on Fan INPUT 6 265VAC D 10 'NOTE: \ OUTPUT 24400.0-10400 ICOM�24010-1D1,I,�/ CLACK WIRE NOT USED Transformer: Included L® i (i oN SOME MOTORS = m mx yr ! 1 2_X4 JUNCTION BOX INPUT VOLTAGE II DRAWINGS 1.2.v2 --- -- -- -- —--- Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 14 of 38 [j 'GREENHECKJob: Red Rock Commons Building Value in Air. Mark: EF B-1 Model: SQ-80-VG SQ-80-VG Min/Max Fan Curve Performance Requested Actual Total External Fan Operating Volume Volume SP(in.wg) RPM Power(hp) (CFM) (CFM) 280 280 0.4 1582 0.06 1.0 0.5 • • 0.8 1'-- 725 p- A - — 0.4 '1582 is �,, 3 0.6 — ii` . —, 0.3 c c a .� L a� co j o a 0.4 - -- - - . — 0.2 CL -- 11 CD .�c U 1 I m CU _ I 0.2 T-_ /_ — 0.1 -- BhP (j) Max FR 'M-- -- 1 -------- ---- -----7.---- - I- ---------- - __. 3O_ RP. I 0.0 --'1"2"—:- I l 1 1 1 1 ! I l l 0.0 0 1 2 3 4 5 6 Volume (CFM) x 100 0 Operating Bhp point O Operating point at Total External SP Fan curve - - System curve Brake horsepower curve Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 15 of 38 GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: EF B-1 Model: SQ-80-VG AMCA amca WORLDWIDE CERTIFIED ROTIRGS SOURD anlo AIR PEREORMAflCE RIR tp nloVEmERT (64. nno coninot •nuc RssoclnTlon '•oma InTERnnrlonnl. Inc. AMCA Licensed for Sound and Air Performance. Power rating(BHP/kW)does not include transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP/kW)does not include transmission losses. Performance ratings do not include the effects of appurtenances(accessories). The inlet sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type B: free inlet hemispherical sone levels. dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies to inlet sone ratings only. Radiated (casing)sound data is the sound generated through the fan housing when the fan is ducted on both the inlet and outlet. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 16 of 38 ayGREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: EF B-2 Model: SQ-70-VG Model: SQ-70-VG Direct Drive Centrifugal Inline Fan Dimensional Quantity 1 Weight w/o Acc's(Ib) 30 Weight w/Acc's(Ib) 37 0.5 0.5 FR A4,1 Performance 0.4 m ® I 0.4 Requested Volume(CFM) 100 to Actual Volume(CFM) 100 rn i Total External SP(in.wg) 0.4 3 V • 0.3 a 0.3 _; Fan RPM 1651 v — Operating Power(hp) 0.03 3 Elevation(ft) 108 vi _ o a� 0.2 - - — — 0.2 � Airstream Temp.(F) 70 ti i Air Density(Ib/ft3) 0.075 0 Tip Speed(ft/min) 3,511 cA ° 0.1 — 0.1 Static Eff.(%) 20 • ��, 1 ----------- ------------ -- ------------ 0.0 I ; 1 I 1 I i i 1 I I I I I A 1 1 1 1 ' , 0.0 0 50 100 150 200 250 300 350 Motor Volume(CFM) Motor Mounted Yes Size(hp) 1/15 Voltage/Cycle/Phase 115/60/1 A Operating Bhp point Enclosure TENV 0 Operating point at Total External SP Fan curve Motor RPM 1725 - -•-••-System curve Windings 1 Brake horsepower curve Notes: All dimensions shown are in units of in. *NEC FLA-based on tables 430.248 or 430.250 of CIMCCI Sound Power by Octave Band National Electrical Code 2014.Actual motor FLA may vary, INORtDEIDE for sizing thermal overload,consult factory. OWIAGED Sound 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones LwA-A weighted sound power level,based on ANSI S1.4 Data dBA-A weighted sound pressure level,based on 11.5 dB fOUAD attenuation per Octave band at 5 ft-dBA levels are not Inlet 68 70 66 51 46 44 40 36 60 48 5.0 licensed by AMCA International 'meted Radiated 67 66 55 • 41 36 , 25 21 23 53 41 2.6 Sones-calculated using AMCA 301 at 5 ft nip movement �v, ',c nuocinToon 9, Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 17 of 38 LtifGREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: EF B-2 Model: SQ-70-VG Model: SQ-70-VG Direct Drive Centrifugal Inline Fan Standard Construction Features: -Galvanized steel housing-Backward inclined composite(sizes 60-95)or aluminum(sizes 97-160)wheel-Two bolted access panels-Integral duct connection flanges-Ball bearing motors(sizes 97-160 and all van-green motors), sleeve bearing motors(sizes 60-95)-Corrosion resistant fasteners Selected Options &Accessories: Motor-Vari-Green EC motor with Dial ONLY(Not capable for field conversion to 0-10) Control-Vari-Green Dial on Exterior of Fan Housing,Mounted and Wired UL/cUL 705 Listed-"Power Ventilators" Switch,NEMA-1,Toggle,Shipped with Unit Junction Box Mounted&Wired Composite Wheel Material Insulated Housing-1 in.Thick:Fan Housing Isolator Mounting Brackets(PN 800201)(Shipped Loose) Unit Warranty: 1 Yr(Standard) Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 18 of 38 LGREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: EF B-2 Model: SQ-70-VG SQ-70-VG Direct Drive Centrifugal Inline Fan 15.75 0 C2 Q 1■CNN ■� 10.80 ra ■E:3 Lo \ 14.0 CY Q TOP VIEW 8.88jSQ. INLET 12.00 � 1 _� L j _ 12.00-- 1.501 13.001 x-1.50 16.00—.-- END VIEW SIDE VIEW Notes:All dimensions shown are in units of in. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 19 of 38 I GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: EF B-2 Model: SQ-70-VG Disconnect Switch Enclosure Rating: NEMA-1 Standard Construction Features: Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor corrosion protection design tests. The rod entry test is intended to simulate incidental contact with enclosure equipment. Enclosure is equipped with provision to lockout in the off position with customer supplied lock. Disconnect Switch Configuration Type: Toggle Motor Size: 1/15 hp Voltage: 115 UL Listed: Yes Manufacturer: Pass and Seymour Cycle: 60 Amperage: 15 CSA Approved: Yes Overload Protection: None Phase: 1 Switch Pole(s): 1 Rating: 1/2 hp Junction Box Mtg.: Mounted and Wired RPM: 1725 Exp. Resist.Wiring: None Switch Mounting: Shipped With Unit Electrical Drawing Details 00.28 (4 HOLES) Wiring Schematic I O 4.35 • O • 1.06 • • 0 1.65 O 0 0.72 — I— 2.00 i 1.06 2.50 '- Notes: Notes:All dimensions shown are in units of in. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 20 of 38 IBGREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: EF B-2 Model: SQ-70-VG Assembly Drawing Type: Direct Drive Centrifugal Inline Fan 15.75 3 0 CEMITI W11111:---- 10.80 a 0Q3 0 ct TOP VIEW 8.88 SQ. INLET 12.00 II I II _ _ —12.001 1.50-- —13.00-- --1.50 16.00 END VIEW SIDE VIEW Notes:All dimensions shown are in units of in.. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 21 of 38 L GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: EF B-2 Model: SQ-70-VG Vari-Green Motor & Control Options An EC motor that uses AC input power and internally converts it to DC power. Motor accepts a 0-10VDC control signal along with a 24V source to power controls in the motor. Motor is operable in the 2-10VDC range and off while in the 0-1.9VDC range. Vari-Green motors feature a soft-start and inherent thermal and current protection built into each unit. Inrush current at start up is eliminated and the motor will automatically reduce speed or turn off if overloaded or it becomes too hot. An EC motor that uses AC input power and internally converts it to DC power. Potentiometer(dial) mounted on the fan housing adjusts the speed (RPM)down 80%. Vari-Green motors feature a soft-start and inherent thermal and current protection built into each unit. Inrush current at start up is eliminated and the motor will automatically reduce speed or turn off if overloaded or it becomes too hot. Motor Configuration Vari-Green Input Voltage: 115 Speed Reference: 0-10VDC 24V Required: No — FACTORY WIRING Permanent Dial: No FIELD WIRING Balance Dial Included: N/A vVA -GREEN. War / FACTORY MOUNTED 4 5 N \ \ / SPEED CONTROL Control Configuration "OLTA'L O O z � O PRESENT 7 Control Type: Dial on Fan NPUT.55-265VAC D ,D NOTE: wTRUT�z4vcc.o—io.roc 1coM124v10-1D'vi SLAC,! WIRE NOT USED Transformer: Included ON SOME MOTORS m d mx 2X4 JUNCTION BOX I INPUT VOLTAGE DRAWING# --- -- -- -- -- 1.2.v2 --- -- -- -- --- Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 22 of 38 Printed Date: 10/14/2019 ai GREENHECK Job: Red Rock Commons • Building Value in Air. Mark: EF B-2 Model: SQ-70-VG SQ-70-VG Min/Max Fan Curve Performance Requested Actual Total External Fan Operating Volume Volume SP(in.wg) RPM Power(hp) (CFM) (CFM) 100 100 0.4 1651 0.03 0.6 i 0.6 17,r$ a. . 4 . -- - 6- .R 0.5 1pt 0.5 RPAA a. 0.4 {_ - - 0.4 ca.. ! s 2,2 0.3 - - — - 0.3 3 Cl) • ;'ao 0.20 0.2 _ ML ++ W CO 0.1 0.1 _v_c___ __ ___ 1 Bhp Max_ F PM 0.0 l ! 0.0 0 50 100 150 200 250 300 350 Volume (CFM) A Operating Bhp point 0 Operating point at Total External SP Fan curve - - - -System curve Brake horsepower curve Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 23 of 38 GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value In Air. Mark: EF B-2 Model: SQ-70-VG AMCA amca WORLDWIDE CERTIflED RATIAGS SOURD ano AIR PEW ORMAIICE RIR 4� n1OVEn1ERT mg)COnTROI •o% nssOCInTIOn QQr InTERnnTIOnnl. inc. AMCA Licensed for Sound and Air Performance. Power rating (BHP/kW)does not include transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating(BHP/kW)does not include transmission losses. Performance ratings do not include the effects of appurtenances(accessories). The inlet sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m)in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type B: free inlet hemispherical sone levels. dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies to inlet sone ratings only. Radiated (casing)sound data is the sound generated through the fan housing when the fan is ducted on both the inlet and outlet. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 24 of 38 �GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value In Air. Mark: SF 1-5 Model: SQ-80-VG Model: SQ-80-VG Direct Drive Centrifugal Inline Fan Dimensional Quantity 1 Weight w/o Acc's(Ib) 46 Weight w/Acc's(Ib) 48 0.70.7 . 1571 F RM R 0.6 —. — 0.6 Performance Requested Volume(CFM) 275 I -- Actual Volume(CFM) 275 0'S 0.5 Total External SP(in.wg) 0.4 3 Fan RPM 1571 E 0.4 m` - Ay — — - 0.4 s Operating Power(hp) 0.06 2 a� a. Elevation(ft) 108 2 0.3 ,,t, — --- — 0.3 a E Airstream Temp.(F) 70 d Air Density(Ib/ft3) 0.075 m 0.2 r w, 0.2 m Tip Speed(ft/min) 4,473 CO Static Eff.(%) 31 0.1 w — 0.1 0.0 i--11' G1 Will Hi IH hili : il ' li II HIT 0.0 0 50 100 150 200 250 300 350 400 450 500 Motor Volume(CFM) Motor Mounted Yes Size(hp) 1/10 Voltage/Cycle/Phase 115/60/1 L\ Operating Bhp point Enclosure TENV 0 Operating point at Total External SP Fan curve Motor RPM 1725 -- ---System curve Windings 1 Brake horsepower curve Notes: All dimensions shown are in units of in. 'NEC FLA-based on tables 430.248 or 430.250 of QmcQ Sound Power by Octave Band National Electrical Code 2014.Actual motor FLA may vary, WORLDWIDE for sizing thermal overload,consult factory. RHOW D Sound 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones LwA-A weighted sound power level,based on ANSI S1.4 Data cot,-A weighted sound pressure level,based on 11.5 dB fO11AD attenuation per Octave band at 5 ft-dBA levels are not Inlet 68 74 69 61 60 57 52 46 66 55 7.5 licensed by AMCA International 1.111/01111 Radiated 67 69 59 51 49 38 33 33 57 45 4.1 Sones-calculated using AMCA 301 at 5 ft qac Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 25 of 38 LGREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: SF 1-5 Model: SQ-80-VG Model: SQ-80-VG Direct Drive Centrifugal Inline Fan Standard Construction Features: -Galvanized steel housing-Backward inclined composite(sizes 60-95)or aluminum(sizes 97-160)wheel-Two bolted access panels-Integral duct connection flanges-Ball bearing motors(sizes 97-160 and all vari-green motors), sleeve bearing motors(sizes 60-95)-Corrosion resistant fasteners Selected Options &Accessories: Motor-Vari-Green EC motor Control-Vari-Green Dial on Exterior of Fan Housing,Mounted and Wired UL/cUL 705 Listed-"Power Ventilators" Switch,NEMA-1,Toggle,Shipped with Unit Junction Box Mounted&Wired Composite Wheel Material Insulated Housing-1 in.Thick:Fan Housing Motor Cover Unit Warranty: 1 Yr(Standard) Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 26 of 38 IBGREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: SF 1-5 Model: SQ-80-VG SQ-80-VG Direct Drive Centrifugal Inline Fan 0 Q i----) i l 0 TOP VIEW rr 11.88 SQ. INLET 15.00 1 _J J J 15.00— 1.50 —16.00--- —1.50 — 19.00 — END VIEW SIDE VIEW Notes:All dimensions shown are in units of in. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 27 of 38 INGREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: SF 1-5 Model: SQ-80-VG Disconnect Switch Enclosure Rating: NEMA-1 Standard Construction Features: Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor corrosion protection design tests. The rod entry test is intended to simulate incidental contact with enclosure equipment. Enclosure is equipped with provision to lockout in the off position with customer supplied lock. Disconnect Switch Configuration Type: Toggle Motor Size: 1/10 hp Voltage: 115 UL Listed: Yes Manufacturer: Pass and Seymour Cycle: 60 Amperage: 15 CSA Approved: Yes Overload Protection: None Phase: 1 Switch Pole(s): 1 Rating: 1/2 hp Junction Box Mtg.: Mounted and Wired RPM: 1725 Exp. Resist. Wiring: None Switch Mounting: Shipped With Unit Electrical Drawing Details 00.28 (4 HOLES) Wiring Schematic I O 4.35 • O • 1.06 • • • O 1.65 L10 0.72 — I— 2.00IIIII I 1.06 -- 2.50 — Notes:All dimensions shown are in units of in. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 28 of 38 Printed Date: 10/14/2019 GREENHECK Job: Red Rock Commons Building Value in Air. Mark: SF 1-5 Model: SQ-80-VG Assembly Drawing Type: Direct Drive Centrifugal Inline Fan 0 ———— Q 0 TOP VIEW 11.88 SQ. INLET 15.00 1 _ I I I 1I �L J —15.00--- 1.50— —16.00— —1.50 19.00 END VIEW SIDE VIEW Notes:AU dimensions shown are in units of in.. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 29 of 38 1351GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value In Air. Mark: SF 1-5 Model: SQ-80-VG Vari-Green Motor & Control Options An EC motor that uses AC input power and internally converts it to DC power. Motor accepts a 0-10VDC control signal along with a 24V source to power controls in the motor. Motor is operable in the 2-10VDC range and off while in the 0-1.9VDC range. Vari-Green motors feature a soft-start and inherent thermal and current protection built into each unit. Inrush current at start up is eliminated and the motor will automatically reduce speed or turn off if overloaded or it becomes too hot. An EC motor that uses AC input power and internally converts it to DC power. Potentiometer(dial) mounted on the fan housing adjusts the speed (RPM)down 80%. Vari-Green motors feature a soft-start and inherent thermal and current protection built into each unit. Inrush current at start up is eliminated and the motor will automatically reduce speed or turn off if overloaded or it becomes too hot. Motor Configuration Vari-Green Input Voltage: 115 Speed Reference: 0-10VDC 24V Required: No FACTOR P WIRWC Permanent Dial: No Balance Dial Included: N/A FIELD WRING .6. -GREEN War FACTORY MOUNTED 4 S G \ SPEED CONTROL Control Configuration V0LrANE ,\ PRESENT zl �l � `J) Control Type: Dial on Fan NPUT 65_2E.`.VAC D ,D NOTE: OUTPU: 245CC, c-,ovoc p�. 0—,w BLACK WIRE NOT iICED Transformer: Included ` CSV - ON SOME MOTORS NS®] / m� � ti✓ ,F 1, L 2X4 JUNCTION BOX I IF DRAWING# INPUT VOLTAGE — _ Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 30 of 38 Printed Date: 10/14/2019 ,GREENHECK Job: Red Rock Commons Building Value in Air. Mark: SF 1-5 Model: SQ-80-VG SQ-80-VG Min/Max Fan Curve Performance Requested Actual Total External Fan Operating Volume Volume SP(in.wg) RPM Power(hp) (CFM) (CFM) 275 275 0.4 1571 0.06 1.0 0.5 I I ! r 0.8 ----g 7,2 'P — ; 0.4 1571 , 1 uli!P0.6 -- 0.3 I 45 co o F2 0.4 - s. 0.2 CL ID U 00 co 0.2 --- —___ P,N , 0.1 - �.� Max FR -------- 300-' RPM - 0.0 0.0 0 1 2 3 4 5 6 Volume (CFM) x 100 0 Operating Bhp point 0 Operating point at Total External SP Fan curve - - - -System curve Brake horsepower curve Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 31 of 38 GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: SF 1-5 Model: SQ-80-VG AMCA amca WORLDWIDE CERTIFIED RRTIRGS SOWID AAD AIR PERFORMAACE RIR tp AIOVEIt1EAT �tti nom COATROI •n% ASSOCIRTIOR ''oma IATERARTIOAAI. Inc.' AMCA Licensed for Sound and Air Performance. Power rating (BHP/kW)does not include transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP/kW)does not include transmission losses. Performance ratings do not include the effects of appurtenances(accessories). The inlet sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type B: free inlet hemispherical sone levels. dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies to inlet sone ratings only. Radiated (casing)sound data is the sound generated through the fan housing when the fan is ducted on both the inlet and outlet. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 32 of 38 'NGREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: Fan Dampers Model: VCD-23 VCD-23 Low Leakage 3V Blade Volume Control Damper APPLICATION & DESIGN The VCD-23 is a ruggedly built low leakage control damper intended for applications in low to medium pressure and velocity systems.A wide range of electric and pneumatic actuators are available. RATINGS Pressure: Up to 5 in.wg-pressure differential I... Channel Frame Velocity: Up to 3,000 ft/min Leakage: Class 1A @ 1 in.wg *I 1 1 Class l@upto5in.wg Temperature: Up to 250 F PRODUCT DETAILS Frame Type: Channel \ \ Frame Thickness: 16 g a a m ` , tin. • Height max Material: Galvanized (typical) Blade Action: Opposed Blade Seal Material: TPE Axle/Linkage Material: SteelPI Axle Bearings: Synthetic -' Jamb Seal Material: Stainless Steel Width Damper Temp.Rating: 180 F y —..J 5 in.- Jackshafting: No Preference Actuator Sizing: Default SqFt Ext.Shaft Length: Standard(6 in.) Multi-Section Fastening: Standard •This drawing shows a general damper configuration and is not Sizing: Nominal intended to depict the exact configuration of all dampers in this submittal. ACTUATOR INFORMATION •Width and height furnished approximately 0.250 in.undersize. •Installation instructions available at www.greenheck.com. Actuator Type: 120 VAC Actuator Mounting: External CODES APPROVED Actuator Location: Left Side IECC(International EnergyConservation Code) aMCCI rt� Operating Mode: TwoPosition w itiio Actuator Operation: Spring Return compliant tames Fail Position: Closed The AMCA Certified Ratings Seal applies to Airi Leakage and Air Performance ratings.NEMA Enclosure: Least Cost &kik/ liliip Auxiliary Switches: Yes OPTIONS & ACCESSORIES Union Label: No Preference SUMMARY ID# TAG 0 QTY I Width ( Height I CONFIGURATION I Drive Arrangement: Drive Actuator Mfr: Actuator Model: . Actuator Qty: i 1-1 (Multiple) 2 9.000 in. ; 9.000 in. CC-11 1FEL-0 Honeywell MS4104F1210 ; 1 { i Act.Orientation: Standoff: I i Parallel 1 500 to Tags:EF 1-4 EF B-2 ._ Drive Arrangement Actuator Mfr: Actuator Model: ' Actuator Qty: Drive- Honeywell MS4104F1210 1 1 2 (Multiple) 2 12.000 in. 12.000 in. CC-11-1FEL-0 I ° Act.Orientation: Standoff I �, I Parallel 1.500 in. Tags:EF B-1 SF 1-5 Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 33 of 38 0GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: Fan Dampers Model: VCD-23 AMCA amca WORIDW IDE CERTIFIED RIITIRGS AIR PERiORMAACE nin tp� mOVEmEnT kr nnD COOTROI •°mac nssOCInTIOn ?oma InTEnnnTIOnnl. Inc. AMCA Licensed for Air Performance&Air Leakage Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs.The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance ratings. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 34 of 38 ajGREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: Louvered Penthouse Model: WRH WRH Exhaust Penthouse APPLICATION & DESIGN The flexible design of the WIH (Intake) and WRH (Exhaust) allows the four louvered sides and hood section(s)to be shipped preassembled. Each section is made of storm resistant aluminum louver blades with mitered corners and a reinforced, removeable cover. The sides are joined at the four corners with stainless steel screws in each louver. These screws are countersunk to maintain the appearance of the mitered corner. The cover is securely fastened to the unit with stainless steel fasterners. Optional factory assembled units are available based on shipping limitations. Greenheck's louvered penthouse design results in low pressure drops,low hood heights and maintains maximum weather resistance. A X B PRODUCT DETAILS Material: Aluminum Sizing: Actual Options and Accessories LOUVER HEIGHT Finish: Mill Bird Screen: 0.75 in.x 0.05 in.,Flat Expanded Aluminum,Internal, 2111 .111: 41.00 Mill Finish Roof Curb: Yes L TW X TL - I Hood: 0.5 in. Insulation Ship Assembled: No CURB CAP WIDTH X A.- Warranty: Warranty: 1 Yr(Standard)Product Warranty CURB CAP LENGTH Summary I Throat Throat Louver Louvers I Curb Cap !Curb Cap, Weight ID# Tag Qty. A(in.) B(in.) ; Free Area(ft2) Width(in.) Length(in.) Height(in.) I High W(in) ' L(in) (Ib) 2-1 Note 5 1 14 14 12.25 3 28 28 22 22 2.60 24 2-2 Note 4 1 14 14 12.25 3 28 28 22 " 22 2.60 24 2-3 1 Note 3 1 16 28 II 12.25 3 30 42 24 36 3.78 35 2-4 Note 2 1 16 2812.25 3 30 42 24 36 3.78 35 2-5 Note 1 7 22 30 j 16 4 36 44 , 30 38 5.63 50 Larger openings may require field assembly of multiple louver panels to make up the overall opening size.Individual louver panels are designed to withstand windloads up to a maximum of 25 PSF(size and configuration dependent).Design,materials and installation of structural reinforcement required to adequately support large sections or multiple section assemblies within a large opening are not provided by.Unless specifically indicated,the following are NOT included in the quote provided:structural steel,installation hardware(anchors,angle clips,continuous angles, shims,fasteners,inserts,backer rod and sealant),field measuring and/or installation,miscellaneous flashing,trim or enclosures,blank off panels,mullion covers or mullion hardware,hinged frames or removable subframes,custom bird/insect screen,3-coat,metallic and/or exotic paint finishes,bituminous paints for unlike metals,any applicable taxes,stamped and sealed structural calculations seismic calculations or job specific engineered submittal drawings. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 35 of 38 L'GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: Louvered Penthouse Model: WRH Louvers Product Limited Warranty Thank you for purchasing Greenheck louvers.Greenheck warrants this equipment to be free from defect in material and workmanship for a period of 1 Yr(Standard)from the date of product shipment.Any units or parts,which prove defective during the warranty period,will be repaired or replaced at our option when returned to our factory,transportation prepaid. Unless agreed upon otherwise Greenheck will not be held responsible for costs associated with removal or installation of product(s). The legal remedies described in this Limited Warranty are the sole exclusive remedy of Customer.This limited warranty will be void if payment from Customer is not received within a commercially reasonable time frame.GREENHECK MAKES NO OTHER WARRANTY,EITHER EXPRESS OR IMPLIED, REGARDING ITS PRODUCTS,OR ITS SELECTION AND APPLICATION,INCLUDING,BUT NOT LIMITED TO,COMPLIANCE WITH BUILDING CODES,SAFETY CODES,LAWS,MERCHANTABILITY OR FITNESS OR A PARTICULAR PURPOSE.This limited warranty is extended solely to the Customer.It is nontransferable and non-assignable,and the Customer shall not permit or authorize its employees,agents,representatives or customers to claim,represent or imply that this limited warranty extends or is available to anyone other than the Customer. In the event of material breach by the Customer of any of the conditions of this warranty,Greenheck shall have no liability for and product failure claims. Failure to pay Greenheck in full for original services will automatically make this warranty null and void. Greenheck will not be held liable for incidental or consequential damages of any kind. The limited warranty of product(s)replaced or repaired under this limited warranty shall be limited to the remainder of the original warranty period. Greenheck reserves the right to reasonable field access to diagnose and repair any product alleged to be defective. This limited warranty may not be modified by anyone and may not be changed by such things as purchase order forms or acceptance forms,unless otherwise agreed upon by Greenheck. This limited warranty is provided in lieu of any other warranty requirements or obligations,including,but not limited to,those within project specifications. All notices and claims given under or pursuant to this agreement shall be in writing and sent by certified or registered mail,postage prepaid,return receipt requested to: Greenheck,Attn: Louver Sales,525 Western Road,Schofield,WI 54476. By proceeding to use our products and services on your project,you accept the terms of these limited warranties. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 36 of 38 J GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: Louvered Penthouse Model: GPI Actual tual W Model: GPI 1.75 '" `� Roof Curb !f Standard Construction Features: Height -Roof Curb fits between the building roof and the fan mounted directly to the roof support structure -Constructed of either 18 ga galvanized steel or 0.064 in. o' 'o. aluminum-Straight Sided without a cant-2 in.mounting flange-3 lb density insulation-Height-Available from 12 in.to 42 in.as specified in 0.5 in. • „,,,,_2, � increments. Notes: -The maximum roof opening dimension should not be \, Flan @ L greater than the"Actual”top outside dimension minus 2 in.. -The minimum roof Flange W opening dimension should be at least 2.5 in.more than the damper dimension or \\ e / recommended duct size.-The Roof Opening Dimension may or may not be the �/ same as the Structural Opening Dimension.-Damper Tray is optional and must be specified. Tray size is same as damper size.-Security bars are optional and must be specified. Frames and gridwork are all 12 ga steel. Gridwork is welded to the frame and the frame is welded to the curb. General ID# Tag Qty Model 2-1 Note 5 1 GPI-22-G12 2-2 Note 4 1 GPI-22-G12 2-3 Note 3 1 GPI-24x36-G12 2-4 Note 2 1 GPI-24x36-G12 2-5 Note 1 7 GPI-30x38-012 Dimensions Curb Curb Cap Curb Cap Actual Actual Flange Height Width Length Width Length Width ID# (in.) (in.) (in.) (in.) (in.) (in.) 2-1 12 22 22 20.5 20.5 4 2-2 12 22 22 20.5 20.5 4 2-3 12 24 36 22.5 34.5 4 2-4 12 24 36 22.5 34.5 4 2-5 12 30 38 28.5 36.5 4 Accessories Insulation Damper ID# Material Liner (in.) Tray 2-1 Galvanized No 1 No 2-2 Galvanized No 1 No 2-3 Galvanized No 1 No 2-4 Galvanized No 1 No 2-5 Galvanized No 1 No Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 37 of 38 LGREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value In Air. Damper Drive Arrangements Job Summary -Start- Drive Arrangement: Drive-CC-11-1 FEL-0 Damper Drive Arrangements Job Summary -End- Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 38 of 38 Drive Arrangement Definition On multi-blade dampers (except vertical blade and Face & Bypass), they are given a drive arrangement code that helps describe the construction of the damper. The following breaks down what each number and letter represents. 22-2FEL- 77 - T I 7 ®� ©0 ® O Number of sections wide ® Number of sections high Jackshaft 0 Number of actuators or manual quadrants I 0 3 173 ® Who supplies the actuators or manual quadrants F- Factory Actuator or c�• C - Customer Supplied (field mounted) Manual Quadrant 3• • Actuator or manual quadrant mounting E - External I - Internal B - Both internal and external ® Actuator or manual quadrant location L- Left hand drive R - Right hand drive B - Both right and left k Damper Width >I 0 Number of jackshafts Vertical blade and face&bypass dampers are given a configuration ID number that helps describe the construction of the damper. See the following examples: Model Drive Arrangement Prefix AMD-23, 33, 42 AMD AMD-42V VB DFD-210, 230; DFDAF-310; MLS DFDAF-330; SEDFD-210 FBH &FBV FB FSD, OFSD, CFSD, SMD, SEFSD, SSFSD, SESMD, SSSMD series MLS (except vertical blade models) FSD-311V, SMD-301V VB GFSD series GFSD ICD series CC IMO series MLS MBD-15&VCD series (except CC vertical blade models) VCD-xxV(vertical blade models) VB Honeywell MS4104, MS4109, MS4604, MS4609, MS8104, MS8109 Fast-Acting, Two-Position Actuators F0FI -/SNO<E CO\TOL A»LICATIO �S PRODUCT DATA FEATURES• • 30 lb-in.(3.4 N•m)or 80 lb-in.(9 N•m)minimum j driving torque at 350°F(176°C) • Reversible mounting facilitates use in either clockwise(cw)or counterclockwise(ccw)spring rotation. UHoneywellre • Integral spring return ensures level of return torque. MS418012 O • Fifteen-second spring return timing. ,4 r=c cnn. • No special cycling required during long-term j holding.(See Operation section.) � �tom. o b S:T » •"' C • No audible noise during holding. • Patent pending design eliminates need for limit ���'is 4 s switches to reduce power consumption. r ' f w• 1 • Models available for 24,120,and 230 Vac. • Ninety-five degree angle of rotation. • Actuator holds rated torque at reduced power level. • Die-cast aluminum housing. • Housing design allows flush mounting to damper. APPLICATION • Designed to operate reliably in smoke control systems requiring Underwriter's Laboratories Inc. The MS4104,MS4109, MS4604, MS4609,MS8104 and UL555S ratings up to 350°F. MS8109 Fast-Acting,Two-Position Actuators are spring return direct coupled actuators(DCA)for Fire and Smoke • Non-UL marked models available. dampers(on/off control).The actuator accepts an on/off • Models available with SPST position-indicating signal from a single-pole,single-throw(SPST)controller. switches(7°,85°stroke). Reversible mounting allows actuator to be used for either clockwise(cw)or counterclockwise(ccw)spring rotation. Contents Application 1 Features 1 Specifications 2 Ordering Information 2 Installation 4 Operation 6 Checkout 6 E 011 C US 63-2740-11 MS4104,MS4109,MS4604,MS4609,MS8104,MS8109 FAST-ACTING,TWO-POSITION ACTUATORS SPECIFICATIONS Mounting:Round 1/2 inch shaft adapter with 1/4 inch set screws. Models:See Table 1. Threads:Y4-20 UNC-2A Material:Alloy Steel hardened to HRC 45-53 Table 1.Models. Thread Lock:Nylon Patch Voltage Internal Auxiliary IMPORTANT Modela (Vac) Switches Honeywell does not recommend using linkages MS4104F1010 120 None with these actuators because side-loading of the output hub reduces actuator life. MS4104F1210 120 2 SPSTb Temperature Ratings: MS4109F1010 120 None Ambient:0°F to 130°F(-18°C to 55°C). MS4109F1210 120 2 SPSTb Shipping and Storage:-40°F to 140°F(-40°C to 60°C). MS4604F1010 230 None IMPORTANT 230SPSTb The actuator is designed to meet UL555S stan- MS4604F12102 dards at 350°F(176°C)on applicable marked MS4609F1010 230 None models.The actuator must be tested with the MS4609F1210 230 b damper to achieve this rating. 2 SPST MS8104F1010 24 None Humidity Ratings:50/0 to 95°/o RH noncondensing. MS8104F1210 24 2 SPSTb Noise Rating(Maximum): MS8109F1010 24 None Driving Open:75 dBA at lm. Holding:20 dBA at lm(no audible noise). MS8109F1210 24 2 SPSTb Controller Type: a Product model numbers with'NM'at the end do not con- MS4104,MS4109:Line voltage(120 Vac), tain an UL listing or marking.Check with local codes and two-position,SPST(Series 40). authority having jurisdiction prior to commissioning this MS4604,MS4609:Line voltage(230 Vac), product type. two-position,SPST(Series 40). b Internal switches are designed to pass UL555S MS8104,MS8109:Low voltage(24 Vac), requirements(at 350°F for 30 minutes)and are intended two-position,SPST(Series 80). for use as position indication,if applicable. Table 2.MS4104,MS4109,MS4604,MS4609,MS8104 Dimensions:See Fig.1. and MS8109 DCA Models. Power Consumption Torque Voltage Minimum Damper Shaft Length: 2 in.(51 mm). in lb-in. Input Device Weight:5 lb(2.3 kg). Model Running Holding (Wm) in Vac MS4104F 0.18A,18W 0.11A, 30(3.4) 120±10%, Stroke:95°±3°,mechanically limited. 9W 50/60 Hz Electrical Ratings:See Table 2. MS4109F 0.25A,23W 0.13A, 80(9) 7W Electrical Connections: MS4604F 0.13A,18W 0.10A, 30(3.4) 230±10%, Power Lead Wires: 11W 50/60 Hz MS410xF and MS460xF:32 inches(0.8m),18 AWG MS810xF:39 inches(lm),18 AWG MS4609F 0.13A,23W 0.09A, 80(9) 7W Switch Lead Wires:18 inches,18 AWG,2 color coded MS8104F 16 VA 8 VA 30(3.4) 24Vac/dc leads +20%,-10%, MS8109F 23 VA 7 VA 80(9) 50/60 Hz ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELIN E®wholesaler or distributor,refer to the TRADELINE®Catalog or price sheets for complete ordering number.If you have additional questions,need further information,or would like to comment on our products or services,please write or phone: 1. Your Local Honeywell Environmental and Combustion Controls Sales Office(check white pages of your phone directory). 2. Honeywell Customer Care 1985 Douglas Drive North Golden Valley, Minnesota 55422-4386 3. http://customer.honeywell.com or http://customer.honeywell.ca International Sales and Service Offices in all principal cities of the world.Manufacturing in Belgium,Canada,China, Czech Republic,Germany,Hungary,Italy,Mexico,Netherlands,United Kingdom,and United States. 63-2740-11 2 MS4104,MS4109,MS46O4,MS4609,MS81O4,MS81O9 FAST-ACTING,TWO-POSITION ACTUATORS Torque Rating(at rated voltage): Table 3.Approvals. Spring Return: MS4104F,MS4604F, MS8104F:30 lb-in.(3.4 N•m). MS4104F, MS4604F, MS8104F, MS4109F,MS4609F,MS8109:80 lb-in.(9 N•m). MS4109F MS4609F MS8109F Stall Maximum: UL/cUL(optional) X X X MS4104F,MS4604F,MS8104F:150 lb-in.(17 N•m). UL6O730(optional) X X X MS4109F,MS4609F,MS8109:240 lb-in.(27 N•m). 350°F Driving: CE X X X MS4104F,MS4604F,MS8104F:30 lb-in.(3.4 N•m). C-Tick X X X MS4109F,MS4609F, MS8109:80 lb-in.(9 N•m). Timing(At Rated Torque and Voltage): Table 4.Environmental Ratings. Drive Open:15 seconds typical. MS41O4,MS4109, Spring Close:15 seconds typical. MS46O4,MS46O9,MS81O4 All Devices and MS8109 Auxiliary Switches: NEMAl IP40 Ratings(maximum load): •MS41O4F,MS4604F,MS41O9F,MS4609F: 125 Vac/24Vdc,3A resistive �-2(51) •MS8104F,MS8109F: -011(25) -.- 24 24 Vac/24 Vdc,3A resistive Settings(fixed):7°nominal stroke,85°nominal stroke ° C,Imo ° '(;/;j li Cycling Requirements: -3/e The actuator and the internal spring are designed to n ^ (1631) /.11.1 require no special cycling during long-term holding. Honeywell recommends following all local,state and national codes for periodic testing of the entire smoke control system.Refer to National Fire Protection Associ- ation(NFPA)National Fire Codes®:NFPA90A,NFPA92A and NFPA92B for your application. NFPA recommends periodic examination of each fire/smoke damper(semi-annually or annually)to ensure proper performance. 1111 I Design Life(at Rated Voltage):30,000 full stroke cycles. 1 8-15/16 (227) iI Approvals:See Table 3. Environmental Protection Ratings:See Table 4. I--2(51)-. -.-3-1/4(83) f-1/16 - 4(102) (2) Accessories: 205649 Mounting Bracket(supplied with actuator). 32003168-004 Shaft Adapter Extension. .-9/16(14) 50006427-001 Flexible Anti-Rotation Bracket. ip _. 5-1/8(130) M34622 Fig.1.MS41O4,MS41O9,MS4604,MS46O9,MS8104 and MS81O9 dimensional drawing in in.(mm). 3 63-2740-11 MS4104,MS4109,MS4604,MS4609,MS8104,MS8109 FAST-ACTING,TWO-POSITION ACTUATORS INSTALLATION When Installing this Product... 1. Read these instructions carefully.Failure to follow ,11 them could damage the product or cause a hazard- 90{ous condition. CtCa 2. Check the ratings given in the instructions and on the ��— product to make sure the product is suitable for your application. 3. Installer must be a trained,experienced service technician. 4. After installation is complete,check out product operation as provided in these instructions. IMPORTANT All wiring must agree with applicable codes, ordinances and regulations. AWARNING Electrical Power Hazard. „ CI�([ Line voltage can cause death or serious injury (� �= and short equipment circuitry. Disconnect power supply before installation. 015 m m n CAUTION A ENSURE THAT MOUNTING ASSEMBLY PREVENTS ACTUATOR ROTATION AND ALLOWS ACTUATOR TO FLOAT ALONG INDICATED Electrical Shock or Equipment Damage Hazard. AXIS. WHEN TOO TIGHT,THE RESULTING BINDING CAN DAMAGE Low voltage can shock individuals or short THE ACTUATOR OR REDUCE TORQUE OUTPUT. M34623A equipment circuitry. Disconnect power supply before installation. Fig.2.Mounting actuator to damper housing. Location and Mounting Preparation The actuators are designed to open a damper by driving Before mounting the actuator onto the damper shaft, the damper shaft in either clockwise /Thi or determine the: counterclockwise ic1 direction.The actuator housing has — Damper/valve opening direction for correct spring two slots on the bottom that,with a 205649 Mounting return rotation.The actuator can be mounted to Bracket,secure it flush to a damper box(see Fig.2).When provide clockwise or counterclockwise spring mounted correctly,these slots allow the actuator to float return. without rotating relative to the damper shaft. — Damper shaft size(see Specifications section). A CAUTION Equipment Damage Hazard. Tightly securing actuator to damper housing can damage actuator. Mount actuator to allow it to float along its vertical axis. 63-2740-11 4 MS4104,MS4109,MS4604,MS4609,MS8104,MS8109 FAST-ACTING,TWO-POSITION ACTUATORS Installation IMPORTANT 1. All wiring must comply with local electrical codes, ordinances and regulations. A CAUTION 2. Voltage and frequency of transformer must corre- spond with the characteristics of power supply and Device Malfunction Hazard. actuator. Improper set screw tightening causes device 3. Use wires rated for at least 75°C(167°F). malfunction. 4. The conduit fittings are designed for use with 3/8 Ensure damper blade is in the correct position and in.reduced-wall steel or aluminum flexible conduit. tighten set screws with proper torque to prevent damper shaft slippage. I-2(±) A CAUTION BLACK 24 VAC RED Actuator Damage Hazard. Lt(-) Using actuator as shaft bearing causes device — — damage. — — Use actuator only to supply rotational torque.Avoid — — any side loads to actuator output coupling bearings. 7°AUXILIARY{ BLUE SWITCH BLUE To install actuator,proceed as follows: YELLOW 1. Place actuator over damper shaft;and hold mounting 85°AUXILIARY SWITCH{ YELLOW 1.? • bracket in place.See Fig.2. 2. Mark screw holes on damper housing. \ 3. Remove actuator and mounting bracket. M34624 Fig.3.Typical 24 Vac wiring. 4. Drill or center-punch holes for mounting screws(or use no.10 self-tapping sheet metal screws). 5. Turn damper blades to desired normal(closed)posi- 1 tion. L2(1)4 WHITE 6. Place actuator and mounting bracket back into posi- 120 VAC tion and secure bracket to damper box with sheet L1(-. pip BLACK metal screws. GREEN 7. Tighten set screws securely into damper shaft using -L minimum 100 lb-in.,maximum 130 lb-in.torque.Use — — 1/4 in.wrench(see Specifications for details)to BLUE - { tighten set screws. 7°AUXILIARY SWITCH BLUE YELLOW Wiring 85°AUXILIARY f YELLOW SWITCH l See Fig.3 through 5 for typical wiring diagrams. \ M34625 ,A WARNING Fig.4.Typical 120 Vac wiring. Electrical Power Hazard. p N Line voltage can cause death or serious injury and r short equipment circuitry. L2(1) BLUE Disconnect power supply before installation. 230 vA \0 BROWN L1(�) A GREEN CAUTION 1 c = Electrical Shock or Equipment Damage Hazard. - Low voltage can shock individuals or short 7°AUXILIARY BLUE - equipment circuitry. SWITCH{ BLUE Disconnect power supply before installation. YELLOW 85°AUXILIARY i SWITCH l YELLOW \ i M34626 Fig.5.Typical 230 Vac wiring. 5 63-2740-11 OPERATION CHECKOUT The MS4104,MS4109,MS4604,MS4609,MS8104 and MS4104F MS4109F (120 Vac MS8109 DCA are designed for use in Smoke Control Systems.If power fails,the actuator spring returns to the 0° model) position.The actuator mounts flush with the damper box. The actuator drives from 0°to 95°and spring returns back 1. Check damper position. to 0°. 2. Connect 120 Vac to the black and white leadwires to drive the damper to the open position.The actuator The actuators are operated by an spst two-position should drive the damper. controller.When using an spst two-position controller,the 3. If the actuator does not spring return,verify that the actuator drives to the damper fully open position when actuator is properly installed.See Installation sec- controller contact makes and spring returns to the damper tion. fully closed position when controller contact breaks.The 4. If the actuator is correctly installed but neither runs actuator drops to holding power level on detection of stall, nor spring returns,replace the actuator. independent of hub position. Cycling MS4604F, MS4609F (230 Vac model) The actuator and the internal spring are designed so that no special cycling during long-term holding is required. 1. Check damper position. Honeywell recommends following all local,state,and 2. Connect 230 Vac to the blue and brown leadwires to national codes for periodic testing of the entire smoke drive the damper to the open position.The actuator control system.Refer to National Fire Protection should drive the damper. Association(NFPA)National Fire Codes :NFPA90A, 3. If the actuator does not spring return,verify that the NFPA92A,and NFPA92B for your application. actuator is properly installed.See Installation sec- tion. NOTE: The actuator is designed to operate for 30 minutes 4. If the actuator is correctly installed but neither runs during a one-time excursion to 350°F(176°C). nor spring returns,replace the actuator. MS8104F, MS8109F (24 Vac model) 1. Check damper position. 2. Connect 24 Vac to the red and black leadwires to drive the damper to the open position.The actuator should drive the damper. 3. If the actuator does not spring return,verify that the actuator is properly installed.See Installation sec- tion. 4. If the actuator is correctly installed but neither runs nor spring returns,replace the actuator. National Fire Codes°is a registered trademark of the National Fire Protection Association(NFPA). 63-2740-11 6 By using this Honeywell literature,you agree that Honeywell will have no liability for any damages arising out of your use or modification to,the literature.You will defend and indemnify Honeywell,its affiliates and subsidiaries,from and against any liability,cost,or damages,including attorneys'fees,arising out of,or resulting from,any modification to the literature by you. Home and Building Technologies In the U.S.: Honeywell Honeywell 715 Peachtree Street NE U.S.Registered Trademark Atlanta,GA 30308 ©2018 Honeywell International Inc. 63-2740-11 M.S.Rev.02-18 customer.honeywell.com Printed in United States EUiLE, ,_ i, , z .T : JOHN1 ,. N AIR PRODUCTS \\<___ __________ 1%; ::::;,;!7 _ SUBMITTAL Fire/Fire Smoke Dampers by Greenheck Project: Red Rock- Tigard Project Address: 11090 SW 68th Pkwy Tigard, OR 97223 Architect: Carleton/Hart Architecture, P.C. Engineer: Fred E. Shaub, Engineer General Contractor: LMC Construction Mechanical Contractor: Mill Creek Heating Date: 10/24/2019 Project: Red Rock - Tigard Project ID: P18-0988 JOHNSON AIR PRODUCTS Table of Contents Tab Submiftal Spec/Sub Page# 1 Fire/Fire Smoke Dampers by Greenheck N/A FSD - Submittals- Red Rock 4 Project: Red Rock - Tigard Project ID: P18-0988 -- JOHNSON AIR PRODUCTS Spec Section: N/A No FSD spec provided 0 0 Submittal Name c a) 2 Fire/Fire Smoke Dampers by Greenheck 0, L Vendor/Subcontractor gQ Johnson Air Products o 0 O E 2 L LL a) 1L LL 0 (a F- Printed Date: 10/14/2019 eGREENHECK Job: Red Rock Commons Building Value in Air. Mark: FD V,R Model: DFD-150X12 DFD-150X12 1 1/2 hour dynamic rated fire damper with 12.000 in. integral sleeve APPLICATION & DESIGN Model DFD-150X12 is approved for use in walls,floors and partitions with fire resistance ratings less than 3 hours. UL 555 classifies dynamic rated fire dampers for use in HVAC systems that are operational in the event of fire. Damper RATINGS Fire Rating: 1'Y2 hours Dynamic Closure Rating Maximum Velocity: 4,000 ft/min vertical mount only, 0111111 up to 24 in.x 24 in.; Height2,000 ft/min vertical or horizontal mount r on all sizes CR 111 CR MaximumPressure: 4 in.wg 10111, Transition a • Transition Damper PRODUCT DETAILS Damper cation Width Sleeve Length f Frame: Galvanized No,Blade: Galvanized Closure Device: Fusible Link Damper Width=Diameter+ttn. Closure Temp: 165 F ore in.minimum Velocity: 2,000 fUmin Damper Height="O"Dimension Mounting: Vertical Sizing: Nominal •This drawing shows a general damper configuration and is not intended to depict the exact configuration of all dampers OPTIONS & ACCESSORIES in this submittal. •Damper is furnished approximately 0.250 in.undersize. Transition: CR Transition Location: Both Sides (Add sleeve thickness for overall sleeved damper dimension) •Installation instructions available at www.greenheck.com. Retaining Angle Type: 2-Side Loose Retaining Angle Size: Minimum UL CODES APPROVED Union Label: No Preference This model meets the requirements for fire dampers established by: •UL Classfied(U.S.and Canada) Standard UL 555(Listing#R13317) •National Fire Protection Association NFPA Standard 80,90A&101 L' PL us •IBC:International Building Codes •New York City:MEA listing#260-91-M •California State Fire Marshal:CSFM listing#3225-981:102 SUMMARY ID# I TAG I QTY Diameter ( CONFIGURATION I Sections Wide: Sections High: "0"Dim: Sleeve Length: 1 1 10.000 in. 12.000 in. 3-1 I 6 ! 7.000 in. —iN-1. Sleeve Thickness Damper Location: 22 ga 6.000 in. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 1 of 5 JJGREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: OFSD Model: OFSD-211 OFSD-211 Out of Wall Combination Fire Smoke Damper APPLICATION & DESIGN Model OFSD-211 is approved for use in walls, partitions and floors with fire resistance ratings less than 3 hours. OFSD-211 is an out of wall" combination fire smoke damper with 3V style blades. Removal of wall grille allows access to the actuator and other components. This model has operational ratings of 2,000 fUmin and pressures to 6 in. wg. Model OFSD-211 shall be installed horizontally or vertically (with blades running horizontally)and is rated for airflow and leakage in either direction. RATINGS UL 555 Fire Resistance Rating ISI Fire Rating: 1 1/2 hours in walls Dynamic Closure Rating: Actual ratings are size dependent Velocity: Up to 2,000 ft/min Pressure: 6 in.wg differential pressure �\ UL 555S Leakage Rating -�, ��■ Leakage Class: I Operational Rating: Actual ratings are size dependent Velocity: Up to 2,000 ft/min �'' Height Pressure: 6 in.wg differential pressure �� Temperature: Up to 350 F depending on actuator ` PRODUCT DETAILS width Frame Type: Channel \ NI Frame Thickness: 16 ga Damper Mounting: Vertical ocaton-- Closure Device: RRL/OCI ^" Sleeve Closure Temperature: 165 F Length Blade Action: Parallel Blade Seal: •This drawing shows a general damper configuration and is not Axle/Linkage Material: Steel intended to depict the exact configuration of all dampers Axle Bearings: 316 SS in this submittal. Grille Depth: 1.250 in. •Width and height furnished approximately 0.250 in.undersize. Wall Thickness: 5.000 in. •Add sleeve thickness for overall sleeved damper dimension. Sizing: Nominal •Dampers with more than one section wide will be furnished with a single OCI device per row when the blade indicator ACTUATOR INFORMATION option is selected. Actuator Type: 120 VAC •Installation instructions available at www.greenheck.com. Actuator Mounting: Internal Actuator Location: Left Side CODES APPROVED Operating Mode: Two Position Model OFSD-211 meets the requirements for fire Actuator Operation: Spring Return dampers,smoke dampers and combination fire smoke Fail Position: Closed dampers established by: Time Cycle: Standard National Fire Protection Association: Operating Temperature: 250 F NFPA Standards 80,90A,92, 101, 105 Velocity: 2,000 ft/min IBC(International Building Codes) C (13US Pressure: 4 in.wg New York City(MEA Listing#260-91-M) NEMA Enclosure: 1 CSFM(California State Fire Marshal) Fire Damper Listing(3225-0981:103) Via,'" OPTIONS & ACCESSORIES Leakage(Smoke)Damper Listing(3230-0981:104) """% Breakaway Actuator Side: Flanged Underwriters Laboratories: r>. 119 Retaining Angle Type: 2-Side Loose UL Classified to U.S.and Canadian safety standards Retaining Angle Size: Minimum UL Standard 555&555S(Listing#R13317) Union Label: No Preference SUMMARY ID# TAG QTY Width Height 1 CONFIGURATION i Drive Arrangement: 1 i Drive- Actuator Mfr: Actuator Model: Actuator Qty: MLS-11-1FIL-1 1 Belimo I FSTF120 I 1 4-1 4 22.000 in. 10.000 in. I Act.Orientation: Sleeve Length: I Sleeve Thickness:I Damper Location:12.000 in. Parallel 21.000 in. �� Flange Width: 0.625 in. 20 ga Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 2 of 5 Printed Date: 10/14/2019 GREENHECK Job: Red Rock Commons ° Building Value in Air. Mark: OFSD Model: OFSD-211 ID# I TAG I QTY I Width I Height I CONFIGURATION Drive Arrangement: Actuator Mfr: Actuator Model: Actuator Qty: Drive MLS-11-1FIL-1 Belimo FSTF120 1 1 4-2 11 ! 12.000 in. 10.000 in. Act.Orientation: Sleeve Length: 1 Sleeve Thickness: . Damper Location: I Parallel 21.000 in. 20 ga 12.000 in. Flange Width: n 0.625 in. _. _ Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 3 of 5 L51GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: OFSD Model: OFSD-211 AMCA amca WORLDWIDE CERTIFIED RATINGS AIR PERIORMARCE nin 4, MOVEMEnT nnD CORTROI •�% nssOCInTIOn '•o.: IfITERnfTIOnfL. MC. ry AMCA Licensed for Air Performance w/o Appurtenances. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 4 of 5 Prin ed Date: 2019 L GREENHECK Job:RRed Rock Commons/ Building Value in Air. Damper Drive Arrangements Job Summary -Start- Drive Arrangement: Drive-MLS-11-1 FIL-1 t- Damper Drive Arrangements Job Summary -End- Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 5 of 5 INGREENHECK POC Retaining Angle Greenheck's one piece retaining angle, the POC (literally named for being a "Piece of Cake") makes damper installation a breeze.The POC angle is designed by fastening four pieces together to form one piece. When installed the angles simply wraps around the sleeve of the damper and is fastened in place. Construction ' •20 ga. (1mm)or 16 ga. (1.5mm) galvanized steel ' �y -�• • Sizes: 11/2 in.x 1'/4 in. (38mm x 32mm) or ' t*~ ' 21/2 x 11/2 in. (64mm x 38mm)for sizes greater than 48 xl inches (1219mm) t-,' 3 Retaining angles for 1 1/2 hour rated fire and combination fire smoke dampers witha width ad height 48 in. (1219mm) .. or less must be a minimum of 20 ga. (1mm)steel. Retaining ' <� 44.. `". angles for all 3 hour rated dampers and all dampers with 00 ? .",.a a width or height greater than 48 in. (1219mm) must be a minimum of 16 ga. (1.5mm). If the damper width plus damper height is less than or equal Retaining angle as shipped from the factory. to 44 inches(1117mm), then the POC angles ship in one The four sides are connected together by rivets in three piece. If damper width plus damper height is greater than 44 corners allowing for easy installation. in. (1117mm), the POC angle ships in two pieces. The POC retaining angles meets the requirements of UL 555 and UL555S. POC Mounting Angle Sleeve ,e Fire-Rated Wall -ter r • f:: k_ /. i t - Convenient Prepunched ' Mounting Holes j , i1111110•• 4 Retaining angle as mounted in the field. The POC angle wraps around the sleeve.The factory provides prepunched mounting holes to further simplfy installation. Available Retaining Angle Options: • Loose -Angle(s)ships unattached to the damper. (DFD series , FD Series, FSD series, VCD series) • Single-Fastened -Angles ships mechanically fastened to the damper sleeve at a specified location. (DFD series , FD Series, FSD series) 111411 Mechanically fastened Ill° along this surface (4 sides) r11110... 11110 •Wrapped -Angle is wrapped around the damper sleeve and tied together. (DFD series , FD Series, FSD series) ---4011111- 40", 110 - Tied here I M GREENHECK Copyright©2019 Greenheck Fan Corporation P.O.Box 410•Schofield,WI 5 44 76-04 10•715-359.6171•g,eenheck.com POC Rev. 10 January 2019 Drive Arrangement Definition On multi-blade dampers (except vertical blade and Face & Bypass), they are given a drive arrangement code that helps describe the construction of the damper. The following breaks down what each number and letter represents. 22-2FE - TT 71 T T CD@ C)0 ® © 0 0 Number of sections wide 0 Number of sections high Jackshaft 0 Number of actuators or manual quadrants 0 Who supplies the actuators or manual quadrants F - Factory = Actuator or fD• C - Customer Supplied (field mounted) Manual Quadrant 0 Actuator or manual quadrant mounting E - External I - Internal B - Both internal and external 0 Actuator or manual quadrant location L- Left hand drive R - Right hand drive B - Both right and left k Damper Width >I 07 Number of jackshafts Vertical blade and face&bypass dampers are given a configuration ID number that helps describe the construction of the damper. See the following examples: Model Drive Arrangement Prefix AMD-23, 33,42 AMD AMD-42V VB DFD-210,230; DFDAF-310; MLS DFDAF-330; SEDFD-210 FBH &FBV FB FSD, OFSD, CFSD, SMD, SEFSD, SSFSD, SESMD, SSSMD series MLS (except vertical blade models) FSD-311V, SMD-301V VB GFSD series GFSD ICD series CC IMO series MLS MBD-15&VCD series(except CC vertical blade models) VCD-xxV(vertical blade models) VB RRL/OCI Option Resettable Link Option with Blade Indicator for Combination Fire Smoke Dampers Application The RRUOCI option performs the function of resettable link and also open or close blade indicator.The RRL option replaces the fusible link on a combination fire smoke damper with an electric sensor(thermostat).The sensor has a fixed temperature setting(165°F, 212°F, 250°F or 350°F[74°C,100°C, 121°C,177°C])and performs the same function as the fusible link that it replaces.The sensor s interrupts power to the actuator and the actuator's spring { return mechanism causes the damper to close.The sensor can be reset after the temperature has cooled down below - the sensor set point. , Before resetting any sensor, a careful inspection of the damper and sensor should be made as exposure to actual 'Wq,j, f fire conditions may render these devices unusable. Second,the OCI assembly contains a single pole,double . . �'t throw switch used to indicate damper blade position.The g switch provides a positive open or closed signal when used ' .r in conjunction with remote indicator lights(furnished by " = ` ,' others).OCI assemblies are used in active smoke control x_ Y"' applications to positively indicate the status of all smoke and combination fire smoke dampers in the building.This single pole/single throw switch assembly may also be used to provide a start/stop control circuit for remote fan installations. To meet UL requirements,factory installation of the damper actuator and factory wiring of the electric sensor is required. If the damper is equipped with a pneumatic actuator,an EP switch is required with an appropriate electric power circuit, to allow the electric thermostat to control the pneumatic actuator. RESETTABLE REUSABLE LINK/ OPEN-CLOSED INDICATOR S � FST O PS ' Ll MST SWRCH YORIXfARY CONGCT L2 ORANGE NC BLACK BLACK © WHITE ••• He ACTUA DAAPER ACID SOLENOID R O PRIMARY TEMP SENSOR VALVE VALVE SWITCHES (10AMP MAX) YELLOW(W/BLUE TAPE) 51(WYOS WHEN1 • DAMPER CLOSES) E BY OTHERS �N0 YELLOW(W/BLUE TAPE) j I� 4• ukaEn YELLOW (W/O BLUE TAPE) I j i, INDICATOR cR I 52(WAKES WHEN ♦ ' I + �� ) �N0 YELLOW (W/O BLUE TAPE) — — I- • Copyright©2008 RRUOCI Option Rev.3 Dec 2008 ArAor FSTF120 US BELIMO On/Off, Spring Return Fail-Safe, 120 VAC I Torque 18 in-Ib,250°F for 30 min,for fire and smoke dampers Application The type FSTF spring-return actuator is intended for the operation of smoke 4' and combination fire and smoke dampers in ventilation and air-conditioning —1 i systems.The actuator will meet requirements of 11555 and UL555S when rtested as an assembly with the damper.Square footage of damper operated will WARRANTY depend on make and model per damper manufacturer UL testing. Operation LIS94 5° Mounting of the actuator to the damper axle shaft or jackshaft is via a cold- TEMP. 6P.IND..a US weld clamp.Teeth in the clamp and V-bolt dig into the metal of both solid and hollow shafts maintaining a perfect connection.The specially designed clamp Technical Data will not crush hollow shafts.The bottom end of the actuator is held by an anti- Power Supply 120 VAC,±10%,50/60 Hz rotation strap or by a stud provided by the damper manufacturer.The actuator Power consumption in operation 2 W,3.5 VA is mounted in its fail safe position with the damper blade(s)typically closed. Power consumption in rest 1.5 W,2.5 VA Upon applying power,the actuator drives the damper to the open position.The internal spring is tensioned at the same time.If the power supply is interrupted, position the spring moves the damper back to its fail-safe position. Shaft Diameter 1/4"to 1/2"round,centers on 1/2" Electrical Connection 3 ft[1 m],18 GA appliance cable with 1/2" conduit connector Overload Protection electronic throughout 0°to 95°rotation Dimensions(Inches[mml) Electrical Protection actuators are double insulated Angle of rotation 95° 0.68°[16.7] Torque motor 18 in-lb[2 Nm] -j direction of rotation motor reversible with CW/CCW mounting M 11111 I'1 10. direction of rotation spring-return reversible with CW/CCW mounting _ Position indication visual indicator,0°to 95° (0°is full spring IL';'li� return position) Running time motor <75 sec @ 250°F[121°C] ``L6.2 ( Running time emergency control <25 sec @ 32...122°F[0...50°C] Standard' I _I�'II1®I position a 1/4 to 1/2 r✓ 1► • Ambient humidity 5 to 95%RH non-condensing ❑ 1/4° to 5/16° - I{�A==% 'Er: 0.2"[5.2] • Ambient temperature 32...122°F[0...50°C] „.o Non-operating temperature 40...176°F[-40...80°C] 0.77”[19s]MEN o.aa^[11] • Degree of Protection IP42,NEMA 2,UL Enclosure Type 2 Housing material UL94-5VA a Agency Listing cULus acc.to UL60730-1N-2-14,CAN/ Safety Notes E CSA E60730-1:02,Listed to UL 2043- Screw a conduit fitting into the actuator's bushing.Jacket the actuator's input suitable for use in air plenums per Section and output wiring with suitable flexible conduit.Properly terminate the conduit C) 300.22(C)of the NEC and Section 602 of in a suitable junction box. c. the IMC. Retrofit Safety Note co California State Fire Marshal Listing 3210- Use of the FSTF for replacement of other makes of actuators is limited in 1593:104 damper area.The FSLF is preferred for direct coupled applications.The FSTF • Noise level,motor <45 dB(A) may be applied for linkage applications on dampers 1.5 sq.ft.and smaller at Noise Level(Fail-Safe) <62 dB(A) velocities under 2000 fpm. • Maintenance maintenance free c, Quality Standard ISO 9001 M Weight 1.59 lb[0.60 kg] 0 'a Part no. Clamp side spring return FSTF120 US CW u 151-F120.1 US CW(bulk pack) FSTF120.1 CCW CCW(bulk pack) o FSTF120-S US CW CW FSTF120-5.1 US CW(bulk pack) FSTF120-S.1 CCW CCW(bulk pack) FSTF24-S.1 US CW(bulk pack) t UL File XAPX.E108966 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN BELIMO FSTF120 US On/Off, Spring Return Fail-Safe, 120 VAC Accessories — — ---KH-TF US TFB(X)crankarm with 5/16"slot. ---KH-TF-1 US TFB(X)crankarm with 1/4"slot. N (White) I1 Neutral KH-TF-1.1 US TFB(X)crankarm for Shafts with 1/4"slot. 't ---TF-P Anti rotation bracket TF/NKOIAM/NM/LM. L1 (Black) f— I ' 2 Hot ---TOOL-06 8mm and 10 mm wrench. ---ZG-TF2 TFB(X)crankarm adaptor kit(T bracket included). ---ZG-TF112 TFB(X)crankarm adaptor kit(includes ZG-113). ---ZS-100 Weather shield-galvaneal(13"L x 8"W x 6"D). ---ZS-150 Weather shield-PC w/foam seal(16"L x 8-3/8"W x 4"D). ---BAE165 US 165°F electric thermal sensor,SPST,normally closed. 45 Typical Specification 120 VAC All smoke and combination fire and smoke dampers shall be provided _ with Belimo FSTF,FSLF,FSNF,or FSAF actuators.All substitutions must be Detector or relay F&S Damper approved before submission of bid.Damper and actuator shall have UL 555S Listing for 250°F&/or 350°E.Actuator shall have been tested to UL 2043 per requirements of IMC 602.2 and NEC 300.22(c).Where position indication isN,L2, required-S models with auxiliary switches or damper blade switches will be HOT 111111111117111 or,CL provided per code requirements. Fusible link F&S or smoke damper Wirin. Diatrams Actuator AProvide overload protection and disconnect as required. To alarm QActuators may be powered in parallel.Power consumption must be system observed. Typical smoke or fusible link damper wiring A Ground present on some models. Meets cULus requirements without the need of an electrical ground Detector or relay F&S Damper connection. HOT N,L2, or COM Manual Actuator reset co0 To alarm system Typical containment damper control wiring AN, L2, Com 1 1 O Hot 2 2 —� Parallel Actuator Wiring O 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN 'rs z---- _ ____ ,__ ::::-_,—_—....—„-- ____ JOHN;---,E ' ON AIR PRODUCTS _:"."1: _____:: _ _ \\N„ ,44; zz::::71r SUBMITTAL GRD's by Titus Project: Red Rock - Tigard Project Address: 11090 SW 68th Pkwy Tigard, OR 97223 Architect: Carleton/Hart Architecture, P.C. Engineer: Fred E. Shaub, Engineer General Contractor: LMC Construction Mechanical Contractor: Mill Creek Heating Date: 10/24/2019 Project: Red Rock - Tigard Project ID: P18-0988 JOHNSON AIR PRODUCTS Table of Contents Tab Submittal Spec/Sub Page# 1 GRD's by Titus M0.03 GRD - Schedule 4 GRD - Submittals- Red Rock 6 Project: Red Rock - Tigard Project ID: P18-0988 JOHNSON AIR PRODUCTS Spec Section: M0.03 Diffuser and Grille Schedule Submittal Name GRD's by Titus Vendor/Subcontractor Johnson Air Products o 0 H Schedule Date/Time: 10/14/2019 11:58:30 Current Version:2014.0.453 Job: Red Rock Commons Modified Version:2014.0.453 Project: Created by:dsmith@johnsonair.com Customer: Schedule Name: StandardStandard Redefine your comfort zone." Sales Person: Douglas Smith Model Symbol/Mark Tag Quantity Description Width Height Slots Slot Module Border End Fastening Damper Finish Accessory Accessory Accessory Config Border -1 -2 -3 23RL EA,RA EA 2 12 6 NONE 1- A- 0- 26- NONE NONE NONE 12X6 SURFACE SCREW NONE WHITE MOUNT HOLES 23RL EA,RA EA 1 22 6 NONE 1- A- 0- 26- NONE NONE NONE 22X6 SURFACE SCREW NONE WHITE MOUNT HOLES 23RL EA,RA RA 8 22 10 NONE 1 - A- 0- 26- NONE NONE NONE 22X10 SURFACE SCREW NONE WHITE MOUNT HOLES 23RL EA,RA RA 1 24 12 NONE 1- A- � 0- 26- NONE NONE NONE 24X12 SURFACE SCREW NONE WHITE MOUNT HOLES 272RS SA SA 11 12 6 NONE 1- A- 0- 26- NONE NONE NONE 12X6 SURFACE SCREW NONE WHITE MOUNT HOLES 272RS SA SA 2 18 10 NONE 1- A- 0- 26- NONE NONE NONE 18X10 SURFACE SCREW NONE WHITE MOUNT HOLES 272RS SA SA 1 18 6 NONE 1- A- 0- 26- NONE NONE NONE 18X6 SURFACE SCREW NONE WHITE MOUNT HOLES Model Symbol/Mark Tag Quantity DIM 1 DIM 2 Module Border Finish Damper Pattern Accessory Accessory Accessory 1 2 3 MCD SB SB 6X6 1 6 6 24X24 3-LAY- 26- 0- NONE NONE NONE INCHES INCHES IN WHITE NONE Page 1 of 2 E:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.pjf v453-v453 Job Name: Red Rock Commons MCD SB SB 8X8 1 8 8 24X24 3-LAY- 26- 0- NONE NONE NONE INCHES INCHES IN WHITE NONE PAR RB RB 2 12 12 24X24 3-LAY- 26- 0- NONE NONE NONE 12X12 INCHES INCHES IN WHITE NONE Page 2 of 2 E:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.pjf v453-v453 Project Red Rock Commons Date 10/14/2019 Architect Office Johnson Air Products Engineer Preparer jbuntrock(a.iohnsonair.com Contractor Redefine your comfort zone. Version 2014.0.453 Designation EA,RA 23RL Aero-Blade return grille, 45° deflection, 3/4" spacing, blades parallel to long dimension, Steel. Main Product 23RL-1 23RL D+1 3/4" -10-1 1/4"1--am D-3/4" 9/16" —.. 1/4" 314" 11111 "IP) � � 4 4 2 7/8" Optional 11/8" Opposed Blade Damper D-1/2" Nominal Duct Size D" Screw Hole Fastening,Grille Mounting Detail Duct Width Duct Height Grille OA Width Grille OA Height 12 6 13.75 7.75 22 6 23.75 7.75 22 10 23.75 11.75 24 12 25.75 13.75 General Description 23RL-1 •One set of 45°fixed horizontal blades. •Optional opposed blade damper has slide adjustment accessible at face of register. •Srcew hole fastening includes#8 x 1 'h"Ig.Phillip's fiat head sheet metal screws painted color of grille. •Sizes larger than 48"x 48"are shipped in multiple sections with joining strips for field assembly. •Odd and fractional sizes are available at additional cost. •All dimensions are in+1/16" •Material is 20 gauge steel for blades and border. Page 1 of 2-Edge Version 2014.0.453-Product Information is Subject to Change without notice Project Red Rock Commons Date 10/14/2019 Architect101 Office Johnson Air Products 1 Engineer Preparer buntrock(a�iohnsonair.com ° P Contractor Redefine your comfort zone. Version 2014.0.453 Designation EARA Option Schedule 23RL-1 ID Quantity Tag WIDTH IN INCHES _ HEIGHT IN INCHES 1 2 _ EA 12X6 12 6 2 1 EA 22X6 22 6 3 8 RA 22X10 22 _ 10 4 1 RA 24X12 24 12 MODULE SIZE NONE DAMPER MODEL 0-NONE BORDER 1 -SURFACE MOUNT ACCESSORY 1 NONE FINISH 26-WHITE ACCESSORY 2 NONE FASTENING A-SCREW HOLES ACCESSORY 3 NONE Page 2 of 2 -Edge Version 2014.0.453 -Product Information is Subject to Change without notice Project Red Rock Commons Date jjEr.corn 0/1401 Architectt* rt OffisPreparerce Contractor Redefine your comfort zone. Version 2014.0.453 Designation RB PAR Perforated Return diffuser, Steel. Main Product PAR-1 PAR Nominal Duct Size(S) TS minus VS"- 3,, AM 11111PLi I 1°1 101 1 8 23 3/d' 24X24 Ceiling Module Nom.Neck Size(S) _ Neck Size 12"X 12" 11 7/8"X 11 7/8" General Description PAR-1 Standard Finish:#26 White •Model PAR flush face perforated ceiling diffusers are designed for use as returns to match the Model PAS supply diffusers. •Can be mounted in a plenum or connected to a return duct. •Perforated face has 3/16"diameter holes on Y,"staggered centers. •Material:Heavy gauge steel. Option Schedule PAR-1 ID Quantity Tag DIM 1 NECK SIZE DIM 2 NECK SIZE 1 2 RB 12X12 12 INCHES 12 INCHES MODULE SIZE 24X24 ACCESSORY 1 NONE BORDER 3-LAY-IN ACCESSORY 2 NONE FINISH 26-WHITE ACCESSORY 3 NONE DAMPER MODEL 0-NONE Page 1 of 1 -Edge Version 2014.0.453-Product Information is Subject to Change without notice Project Red Rock Commons Date 10/14/2019 Architect Titus *1 Office Johnson Air Products Engineer Preparer jbuntrockl7a.iohnsonair.com Contractor Redefine your comfort zone. Version 2014.0.453 Designation SA 272RS Aero-Blade double deflection supply grille, 3/" spacing, blades parallel to short dimension, Steel. Main Product 272RS-1 272RS D plus 1 3/4" --eo— 1 1/4"his D minus 3/4" 9/16"--.-- — 13/4" - 3116" II 111111111111111 Jt 1 11/16" / i 3 7/16" Optiodnal-1►Blade 11 Oppose Damper Note: D minus 1/2" When Damper Is Full Open Add 3/8" To Overall Depth. Nominal Duct Size D" Screw Hole Fastening,Grille Mounting Detail VA 00/ Duct Width Duct Height Grille OA Width Grille OA Height 12 6 13.75 7.75 18 10 19.75 11.75 18 6 19.75 7.75 General Description 272RS-1 •Aerodynamically shaped blades are individually adjustable. •Optional opposed blade damper has screwdriver adjustment accessible through face of register. •Srcew hole fastening includes#8 x 1 '/,"Ig.Phillip's flat head sheet metal screws painted color of grille. •All dimensions are±1/16" •Material is 20 gauge steel for border and heavy extruded aluminum for blades. Option Schedule 272RS-1 ID Quantity Tag WIDTH IN INCHES HEIGHT IN INCHES 1 11 SA 12X6 12 6 2 2 SA18X10 18 10 3 1 SA 18X6 _ 18 6 Page 1 of 2- Edge Version 2014.0.453-Product Information is Subject to Change without notice Project Red Rock Commons *° Date 10/14/2019 Architect m Office Johnson Air Products Engineer Preparer buntrock{a�Iohnsonair.com Contractor Redefine your Comfort zone. Version 2014.0.453 Designation SA Option Schedule(continued) 272RS-1 MODULE SIZE NONE ACCESSORY 1 NONE BORDER 1 -SURFACE MOUNT ACCESSORY 2 NONE FINISH 26-WHITE ACCESSORY 3 NONE DAMPER MODEL 0-NONE Page 2 of 2 -Edge Version 2014.0.453- Product Information is Subject to Change without notice Project Red Rock Commons E:rer Er.corn 9 Architectlitus Contractor Redefine your comfort zone: Version 2014.0.453 Designation SB MCD Modular core diffuser, Steel. Main Product MCD-1 MCD Border Type 3(Lay-In) 24"x 24"Module Size Duct Size Duct Size minus 1/8" 2'/8"�� 5/8" 23 3/4"x 23 3/4" Duct Size 6"x6" 8"x8" General Description MCD-1 •The Model MCD modular core diffuser is an extremely flexible diffuser.The model MCD can be adjusted for 1,2,3,or 4-way air patterns after being installed. •Model MCD diffuser maintains a horizontal flow pattern from maximum to minimum CFM making it an excellent choice for variable air volume applications. •MCD is shipped with the modular cores set for 4-way throw. •Material is Steel Option Schedule MCD-1 ID Quantity Tag DIM 1 NECK SIZE DIM 2 NECK SIZE 1 1 SB 6X6 6 INCHES 6 INCHES 2 1 SB 8X8 8 INCHES 8 INCHES MODULE SIZE 24X24 ACCESSORY 1 NONE BORDER 3-LAY-IN ACCESSORY 2 NONE FINISH 26-WHITE ACCESSORY 3 NONE DAMPER MODEL 0-NONE Accessories MCD-1 Modular Core Arrangements - • E-74 ,HgIII111H• •W-1:• s II •II Il hi- Page 1 of 1 - Edge Version 2014.0.453- Product Information is Subject to Change without notice D ,----- '-'-' ,\ JOHNSON AIR PRODUCTS \\N„. SUBMITTAL Louvers by Greenheck Project: Red Rock - Tigard Project Address: 11090 SW 68th Pkwy Tigard, OR 97223 Architect: Carleton/Hart Architecture, P.C. Engineer: Fred E. Shaub, Engineer General Contractor: LMC Construction Mechanical Contractor: Mill Creek Heating Date: 10/24/2019 Project: Red Rock - Tigard Project ID: P18-0988 JOHNSON AIR PRODUCTS Table of Contents Tab Submittal Spec/Sub Page# 1 Louvers by Greenheck N/A Louvers-Submittals- Red Rock 4 Project: Red Rock - Tigard Project ID: P18-0988 JOHNSON AIR PRODUCTS Spec Section: N/A No Louver spec provided. Submittal Name Louvers by Greenheck Vendor/Subcontractor 0 Johnson Air Products 0 as 1=3GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value In Air. Mark: Louvers Model: ESD-435 ESD-435 4 in. Frame, 35 deg Blade APPLICATION & DESIGN ESD-435 is a weather louver designed to protect air intake and exhaust openings in building exterior walls.Design incorporates drain gutters in the head member and horizontal blades to channel water to the jambs where water is further channeled through vertical downspouts and out at the sloped sill. The ESD-435 is an extremely efficient louver with AMCA LICENSED PERFORMANCE DATA enabling designers to select and apply with confidence. PRODUCT DETAILS Frame: 4 in.x 0.081 in.Frame Thickness Internal View j' Frame Type: Channel / Blades: 0.081 in.Fixed Blade Thickness Material: Aluminum I Sizing: Nominal Shape: Rectangular i l' Construction: Mechanically Fastened P • � OPTIONS & ACCESSORIES ii Finish: Kynar 70%(2 coat),Match Color Chip,(,To Be Selected,IHB) I Bird Screen: 0.5 in.x 0.063 in.,Mesh Aluminum,Internal,Match ii Louver Finish Warranty: 1 year Standard Product Warranty - 10 year Standard Finish Warranty .i ll :i i i ii. Width and Height furnished approximately 0.250 in.under size. SUMMARY ID# TAG QTY. W(in.) H(in.) FREE AREA ' FREE AREA ; 1. _._ ., O.. .._ (%) f SECT.WIDE j SECT HIGH;SHIP SECT. 5-1 3 12 18 0.54 35.8 1 1 3 5-2 17 18 18 0.88 39.3 1 1 17 5-3 2 18 24 1.30 43.2 1 1 2 5-4 1 18 36 2.13 47.4 1 1 1 Total Louver Qty: 23 Total Weight(Ib): 181 Louver Area(ft2): 53 Total Ship Sect.: 23 "Weight shown is an estimate only based on the default base product configuration without options or accessories. Larger openings may require field assembly of multiple louver panels to make up the overall opening size.Individual louver panels are designed to withstand windloads up to a maximum of 25 PSF(size and configuration dependent).Design,materials and installation of structural reinforcement required to adequately support large sections or multiple section assemblies within a large opening are not provided by Greenheck.Options and accessories including,but not limited to,screens,filter racks,louver doors,and blankoff panels are not subject to structural analysis unless indicated otherwise by Greenheck.Unless specifically indicated,the following are NOT included in the quote provided:structural steel,installation hardware(anchors,angle clips,continuous angles,shims,fasteners,inserts,backer rod and sealant),field measuring and/or installation,miscellaneous flashing,trim or enclosures,blank off panels,mullion covers or mullion hardware, hinged frames or removable subframes,custom bird/insect screen,3-coat,metallic and/or exotic paint finishes,bituminous paints for unlike metals,any applicable taxes,stamped and sealed structural calculations seismic calculations or job specific engineered submittal drawings. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 1 of 4 111 GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value In Air. Mark: Louvers Model: ESD-435 Louvers Product Limited Warranty Thank you for purchasing Greenheck louvers.Greenheck warrants this equipment to be free from defect in material and workmanship for a period of 1 year from the date of product shipment.Any units or parts,which prove defective during the warranty period,will be repaired or replaced at our option when returned to our factory,transportation prepaid.Unless agreed upon otherwise Greenheck will not be held responsible for costs associated with removal or installation of product(s). The legal remedies described in this Limited Warranty are the sole exclusive remedy of Customer.This limited warranty will be void if payment from Customer is not received within a commercially reasonable time frame.GREENHECK MAKES NO OTHER WARRANTY,EITHER EXPRESS OR IMPLIED,REGARDING ITS PRODUCTS,OR ITS SELECTION AND APPLICATION,INCLUDING,BUT NOT LIMITED TO,COMPLIANCE WITH BUILDING CODES,SAFETY CODES,LAWS,MERCHANTABILITY OR FITNESS OR A PARTICULAR PURPOSE.This limited warranty is extended solely to the Customer. It is nontransferable and non-assignable,and the Customer shall not permit or authorize its employees,agents,representatives or customers to claim,represent or imply that this limited warranty extends or is available to anyone other than the Customer. In the event of material breach by the Customer of any of the conditions of this warranty,Greenheck shall have no liability for and product failure claims. Failure to pay Greenheck in full for original services will automatically make this warranty null and void. Greenheck will not be held liable for incidental or consequential damages of any kind. The limited warranty of product(s)replaced or repaired under this limited warranty shall be limited to the remainder of the original warranty period. Greenheck reserves the right to reasonable field access to diagnose and repair any product alleged to be defective. This limited warranty may not be modified by anyone and may not be changed by such things as purchase order forms or acceptance forms,unless otherwise agreed upon by Greenheck. This limited warranty is provided in lieu of any other warranty requirements or obligations,including,but not limited to,those within project specifications. All notices and claims given under or pursuant to this agreement shall be in writing and sent by certified or registered mail,postage prepaid,return receipt requested to: Greenheck,Attn: Louver Sales,525 Western Road,Schofield,WI 54476. By proceeding to use our products and services on your project,you accept the terms of these limited warranties. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 2 of 4 GREENHECK Printed Date: 10/14/2019 Job: Red Rock Commons Building Value in Air. Mark: Louvers Model: ESD-435 Louvers Architectural Finish Limited Warranty Kynar/Hylar and Mica (70% PVDF) Paint Greenheck warrants the finish of Kynar/Hylar(70% PVDF)paint for a period of 10 Yrs(Standard) from the date of product shipment when applied to aluminum louvers or aluminum architectural products. Greenheck warrants that for after the date of product shipment the applied finish: A) Will not chip, crack or peel (lose adhesion)but does not include minute fracturing, which may occur in proper fabrication of building parts. B) Will not chalk in excess of ASTM D-4214-89 number 8 rating, determined by the procedure outlined in ASTM D-4214-89 specification test. C) Will not change color more than five(5) Delta-E Hunter units(square root of the sum of Delta L, Delta A and Delta B)as determined by ASTM method D-2244. It is acknowledged that fading or color changes may not be uniform if the surfaces are not equally exposed to the sun and elements. Metallic and Mica colors are exempt in the warranty from item C but will hold the L value within 5 Delta E or the L scale of the Hunter E unit system. Exotic colors will receive a full 10 year warranty if they have the recommended clear coat applied. However, Exotic colors are excluded from the 20 year warranty. Any units or parts,which prove defective during the warranty period,will be repaired or replaced at our option when returned to the factory, transportation prepaid. Unless agreed upon otherwise Greenheck will not be held responsible for costs associated with installation or removal of product(s). Greenheck limited warranties are not applicable when failure is caused by events that cannot be controlled by Greenheck. These include, but are not limited to, Acts of God,fire or other casualty or physical damage; Government restrictions;Acts of aggression; Harmful fumes or foreign substances in the atmosphere; Improper storage or packaging of the parts prior to installation; Product failure due to improper usage and/or application; Failure to provide reasonable and routine maintenance and/or improper maintenance, including, but not limited to the use of chemical cleaning agents not in accordance with AAMA recommendations or failure to use a systematic maintenance cleaning program in areas of high salt concentration; Corrosive atmosphere found in the interior of buildings,which effect the interior surface of material; Standing or ponding water on the metal; Excessive building movements;Work performed or materials supplied by others; Improper treatment of finished material; Corrosion of the metal substrate; Incompatibility between materials, including, but not limited to, Galvanic corrosion due to contact with adjacent dissimilar metals such as stainless steel; Damage to the painted metal occasioned by moisture or other contamination detrimental to the finish because of improper storage of the finished metal prior to installation as outlined in AAMA Publication 10, "Care and handling of Architectural Aluminum From Shop to Site." The legal remedies described in this Limited Warranty are the sole exclusive remedy of Customer. This limited warranty will be void if payment from Customer is not received within a commercially reasonable time frame. GREENHECK MAKES NO OTHER WARRANTY, EITHER EXPRESS OR IMPLIED, REGARDING ITS PRODUCTS, OR ITS SELECTION AND APPLICATION, INCLUDING, BUT NOT LIMITED TO, COMPLIANCE WITH BUILDING CODES, SAFETY CODES, LAWS, MERCHANTABILITY OR FITNESS OR A PARTICULAR PURPOSE. This limited warranty is extended solely to the Customer. It is nontransferable and non-assignable, and the Customer shall not permit or authorize its employees, agents, representatives or customers to claim, represent or imply that this limited warranty extends or is available to anyone other than the Customer. In the event of material breach by the Customer of any of the conditions of this warranty, Greenheck shall have no liability for and product failure claims. Failure to pay Greenheck in full for original services will automatically make this warranty null and void. Greenheck will not be held liable for incidental or consequential damages of any kind. The limited warranty of product(s) replaced or repaired under this limited warranty shall be limited to the remainder of the original warranty period. Greenheck reserves the right to reasonable field access to diagnose and repair any product alleged to be defective. This limited warranty may not be modified by anyone and may not be changed by such things as purchase order forms or acceptance forms, unless otherwise agreed upon by Greenheck. This limited warranty is provided in lieu of any other warranty requirements or obligations, including, but not limited to, those within project specifications. All notices and claims given under or pursuant to this agreement shall be in writing and sent by certified or registered mail, postage prepaid, return receipt requested to: Greenheck, Attn: Louver Sales, 525 Western Road, Schofield,WI 54476. By proceeding to use our products and services on your project, you accept the terms of these limited warranties. Generated by:jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 3 of 4 Printed Date: 10/14/2019 �GREENHECK Job: Red Rock Commons Building Value In Air. Mark: Louvers Model: ESD-435 AMCA MCA WORLDWIDE CERTIFIED RATIAGS UTATER PEmETRmTIAn RIR PERrORMAACE nin titc, MOVEMEnT w nnD cOnTnOt *9% nssocmTion •o,, mrennnTionnt. inc. Greenheck Fan Corporation certifies that the louver shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance and water penetration ratings. The AMCA licensed performance data has been modified for installation, appurtenances, accessories, etc. not included in the certified data. The modified performance is not AMCA licensed but is provided to aid in selection and applications of the air control device. Generated by.jbuntrock@johnsonair.com CAPS 4.30.1721 B:\JacobBuntrock\Secured Jobs 2019\Red Rock Commons.gfcj Page 4 of 4 ,---- rj, E EL1c,.. ...,, JOHik ' T --, ". "-:- ON AIR PRODUCTS SUBMITTAL Packaged Terminal Heat Pumps by Amana Project: Red Rock - Tigard Project Address: 11090 SW 68th Pkwy Tigard, OR 97223 Architect: Carleton/Hart Architecture, P.C. Engineer: Fred E. Shaub, Engineer General Contractor: LMC Construction Mechanical Contractor: Mill Creek Heating Date: 10/24/2019 Project: Red Rock - Tigard Project ID: P18-0988 JOHNSON AIR PRODUCTS Table of Contents Tab Submittal Spec/Sub Page# 1 Packaged Terminal Heat Pumps by Amana M0.03 4 PTHP's- Submittal - Red Rock Project: Red Rock - Tigard Project ID: P18-0988 JOHNSON AIR PRODUCTS Spec Section: M0.03 Typical Packaged Terminal Heat Pump Schedule co C Submittal Name Packaged Terminal Heat Pumps by Amana u, Vendor/Subcontractor (1) Johnson Air Products 76 a) C6 QTY:(8) PTH073G35AXXX TAG: PTHP-A QTY:(9) PTH093G50AXXX TAG: PTHP-B QTY:(27) PTH123G25AXXX TAG: PTHP-C QTY:(4) PTH153G25AXXX TAG:PTHP-D Heating&Air Conditioning ana PACKAGE TERr 1\4 '. C0N I4i I N R (PIAL) AND HEAT PUMP Specifications and Accessories Catalog `, -& , tE Wise Decision. °� �` � �� r It's an Amana® brand. ; . N & � r .n r ; III r f / Z } " .",•` _ �tf«,t - __ mana is a registered trademark of Maytag Corporation or its related companies and is used under license to Goodman �_'� w A Company,L.P.,Houston,TX,USA.All rights reserved. Premium Amana` / Featuring / Web Based Brand Quality DigiSmart Monitoring Standard Features • Energy Efficiencies:With EERs up to 13.1 and COPs • 7%"Unit Front Depth: Enhance valuable room up to 3.6,our unit's high efficiencies may qualify space with our slim unit front,which has a sleek you for many of the rebates offered by electrical 7%"depth,one of the shallowest silhouettes in power companies. the industry today.In addition,to inhibit guest- • Quiet Operation:Our PTAC has been redesigned to be tampering,the front can be secured to the chassis the quietest PTAC we've ever built.The unit's state- with a hidden screw. of-the-art design and construction provide a quiet • Easy Pull-Out Filters:Our filters are washable and environment,allowing guests to enjoy peaceful, easy to maintain. sleep-filled nights. • Filter Dryer for Sealed System Refrigerant:Standard — Two fan motors(indoor/outdoor) in all units to protect the compressor and lengthen the - Indoor tangential fan for quiet operation life of the unit by removing moisture and preventing — STC of 28 acid formation. • Assembled in the USA for 40 years:assembled at our • Condensate Dispersion System:Our condensate plant in Fayetteville,TN,using Goodman resources dispersion system removes condensate from indoor including engineering,production,and testing. cooling operation by throwing water directly on to the outdoor coil for rapid evaporation and increased • Increased Dehumidification Capacity:Maintain lower cooling efficiencies.The slinger ring on the new, humidity levels in rooms while cooling them without enhanced fan draws water up and into the fan blades. the need for expensive add-ons.As a result,guests feel This water is then atomized and evaporated into the more comfortable at higher temperatures,thus atmosphere through the condenser.Increased surface reducing cooling costs. area from the coil allows more water to be evaporated • Seven-Button Touch Pad:Provides complete control on the sides of the coils and helps to minimize to guests for in-room comfort while maintaining condensate run-off. energy efficiency. ■ Front Desk Control:Each unit comes equipped with • Five-Year Limited Warranty:Enjoy one of the most the DigiSmart'"control and energy management comprehensive warranties in the industry:First Year: software.Using the DigiSmart'"software and optional parts&labor;Second through fifth years:parts RF Antenna,all units can be wirelessly connected &labor on certain sealed system components; to a central hub for enhanced energy savings and second through fifth years:on certain functional diagnostics.Amana brand PTACs also have a low- parts only.For complete warranty details,visit voltage interface capability with a field-supplied www.amana-ptac.com. front-desk ON/OFF switch.(See inside front cover.) • 100%Run Tested:All units are 100%run tested at our plant in Fayetteville,TN,including leak checks during manufacturing and again prior to shipment at the warehouse. Heating A Air Conditioning ana AMERICA'S BRAND FOR COMFORT' • Room Freeze Protection:When the unit senses • 30-Second Fan-Off Delay:The fan continues to run temperatures of 40°F or below,the unit activates 30 seconds after the compressor has stopped in either the fan motor and either the electric resistance cooling or heat pump mode and after electric heat has heater or the hydronic heater. been turned off.This improves efficiency by dispersing • Easy-to-use Controls:No complex controls to confuse the conditioned air on the coils into the room. your guests and create phone calls for your manager. • Compressor Lock-In:This feature helps prolong the life Controls are easy to read,understand,and activate. of the compressor by preventing short-cycling.When Our new 7-button control panel provides guests with the compressor is switched from Off to On because complete control of the unit for their in-room comfort room temperature has risen or fallen below the while maintaining overall energy efficiency. specified limit,it will remain on for at least 4 minutes. • Easy to Service with On-Board LED Diagnostics: If the temperature set-point is changed during this The main components are easily serviced and there 4 minutes,the lock-in feature is overridden. is no guessing to determine the problem with our • Automatic Emergency Heat:No more"my unit is not easy-to-read diagnostics. heating"complaints during the middle of the night. • Stonewood Room Front:Our Stonewood room front Heat pump units will automatically switch over to strikes the balance between attractive styling and electric resistance heat if the heat pump compressor practical design.Distinctive contours and a modern system fails or if the heating load is greater than the appearance enhance the character of even the most unit capacity. luxurious room,while the sleek 75/s"depth maximizes • Constant Fan Mode:Take advantage of each unit's usable space for your guests. dual options—select continuous fan operation or • Remote Thermostat Control:When the DigiSmart°" cycle the fan ON and OFF with the thermostat. wireless remote thermostat(DS01E,sold separately)is Our 7-button design allows guests to select fan set up,both the remote thermostat and unit control performance while allowing the owner to have the panel continue to control the unit,providing flexibility unit revert to the desired program of continuous and home-like system control.Installation requires no fan or cycle with conditioning. more than pressing two buttons.No need to run wires • Hidden Ventilation Control:The ventilation control or make electrical connections. lever is hidden from the occupant's view to allow you • Extended Heat Pump Heating:Heat pump models to manage ventilation requirements. will operate in the heating mode down to as low as ■ High-Pressure Switch:Protects the unit from high 24°F outdoor ambient temperature. pressure and damage to the unit,helping to ensure • Zero Floor Clearance:The unit can be installed flush long unit life. to a finished floor,if desired. (Some accessories do not have zero clearance). Si��cili( 5 Nomenclature PTC 07 3 G35 AXXX AA 1,2,3 4,5 6 7 8,9 10,1132,13 14,15 r _ Basic Model Type 1 Engineering PTC Standard Cooler PTAC Major&Minor Revisions PTH Standard Heat Pump PTHP HEC High-Efficiency Cooler PTAC Features Code• HEH High-Efficiency Heat Pump A Standard Model 32C High-Efficiency R32 Cooler PTAC C Corrosion Protection(Seacoast) DRY Dehumid Cooler PTAC D Power Door PMC DigiAIR Cooler PTAC F Fuse Holder(230/208 Only) PMH DigiAIR Heat Pump PTAC L Lighting Control Nominal Cooling Capacity H Hydropic Heat-Capable 07 7,000 BTU/h 60 Hz P Condensate Pump(PTH Only) 09 9,000 BTU/h 60 Hz 4 Quiet STC 31 Chassis 10 10,000 BTU/h 50 Hz R RF Antenna 12 12,000 BTU/h 50 or 60 Hz V Power Vent 15 15,000 BTU/h 60 Hz X placeholder 17 17,000 BTU/h 60 Hz W Hard-Wired(PTAC) Rated Voltage Heater Size 2 115V,60 Hz,1 Phase 00 No Electric Heat 35 3.5 kW(230/208V) 3 230/208V,60 Hz,1 Phase 15 1.5 kW 3.7 kW(265V) 4 265V,60 Hz,1 Phase 25 2.5 kW 50 5.0 kW 5 240/220V,50 Hz,1 Phase Export Use up to 4 as needed in alphabetical order.Examples: Design Series PTC123'SOAXXX PTC073.35CRXX G R-410A PTC123•SOCXXX PTC073.25CQRW H High-Efficiency R-410A 1 High-Efficiency R-32 Power Cord Configuration Power Cord Plugs Power Receptacle Configuration 250V Rating Power Cord Plugs with LCD)Device NEMA 6 Configuration oG oc., _ _____ IOO • I ) • 0 --- ' NEMA6-15R;250V NEMA6-20R;250V NEMA6-30R;250V 15 amp 20 amp 30amp receptacle used on receptacle used on receptacle used on 230/208V units 230/208V units 230/208V units 277V Rating Power Cord Plugs CIG CIG NEMA 7 Configuration Q WO 0 a wU mmoin NEMA7-20R;277V receptacle NEMA7-30R;277V receptacle • • • � used on 265V units used on 265V units 20 amp ---- ao amp All units come with factor-installed power cords. All units less than 250 volts come with LCD!device. 6 rr . He,.ting 8 Air Conditioning ana AMERICA'S BRAND FOR COMFORT' ' 'duct Specifications: 32C Models - Cooling/Electric Heat 230/208 Volts Model6.a,9 32C 32C 32C 32C 073J***XXX 093J***XXX 123J** X 153J***XXX Voltage 230/208 230/208 30/208 230/208 Capacity(BTU/h) 7,700/7,700 9,000/9,000 11,700/11,500 15,000/14,700 Ampst" 4.3/4.3 4.6/• • 6.2/6.2 7.5/7.5 Watts10 •a 585 r /695 1050/1040 1415/1385 EER 13.0 '. 12.7/12.9 11.5/11.5 10.6/10.6 Unit without Electric Heater Min.Circuit Amps 2'4'1° 5.1 4 7.4 9.1 CFM(Cool/Wet Coil) Hig 290 290 290 340 ow 264 264 264 314 CFM(Dry Coil) High 310 310 0 360 Low 282 282 282 332 Ventilated Air,CFM -• Only)* 65 65 65 65 Dehumidific. (Pints/Hr.) 1.7 2.2 3.6 4.4 Net W•': (lbs.) 98 102 102 1 ' •..Weight(lbs.) 113 117 119 130 Product Specifications: PTH Models - Cooling/Heat Pump/Electric Heat MODEL I'5'8,9 PTH073G PTH093G 1 PTH123G PTH153G PTH074G PTH094G PTH124G PTH154G **AXXX **AXXX **AXXX **AXXX **AXXX **AXXX , **AXXX **AXXX Voltage 1 3 230/;208 230/VP 230/ ' 230 va. 265 265 265 265 Capacity(BTU/h) 7,600/7,600 9,000/"),000 12,000/ 14,700/ 7,600 9,100 12,000 14,600 12,000 14,700 Amps 10 3.9/3.9 4.2/4.2 5.8/5.8 7.0/7.0 3.1 3.7 5.0 6.1 Watts 10 650/633 750/+.750 1,090/1,090 1,515/,1,515 650 758 1,091 1,505 EER 11.7/a0.0 12.0/, 2.0 11.0/1,1, 9.7/t9.7 11.7 12.0 11.0 9.7 UNIT WITHOUT ELECTRIC HEATER Min.Circuit Amps 2,4,10 4.7 5.1 7.1 8.5 3.8 4.5 6.1 7.4 High ,;340 330 340 390 340 330 340 390 CFM(Cool/Wet Coil) Low 245 245 245 340 245 245 245 340 High 370 '360 370 410 370 360 370 410 CFM(Dry Coil) Low 270 270 270 370 270 270 270 370 Ventilated Air,CFM(Fan Only)* 65" 65* 65" 65* 65* 65" 65* 65* Dehumidification(Pints/Hr.) 1.7 2.2 3.6 4.4 1.7 2.2 3.6 4.4 Net Weight(lbs.) 108 112 115 126 108 112 115 125 Ship Weight(lbs.) 123 127 132 143 123 127 132 142 *Actual vent CFM performance will vary due to application and installation conditions. NOTES 1 All 265-volt models must use an Amana0 brand sub-base(PTSB4*'E)or an Amanaebrand hard-wire kit PTPWHWK4 and disconnect switch PSHWO4A. * Minimum Circuit Ampacity(MCA)ratings conform to the National Electric Code;however,local codes should apply. 3 Minimum voltage on 230/208-volt models is 197 volts;maximum is 253 volts.Minimum voltage on 265-volt models is 239 volts;maximum is 292 volts. o Overcurrent protection for all units without electric heaters is 15 amps.Overcurrent protection on 265-volt models must be cartridge-style time-delay fuses(included and factory-installed on all Amana0 brand 265-volt chassis).See heater performance * Heating capacity and efficiency based on unit operation without condensate pump;unit automatically switches to electric heat at approximately 24°F outdoor ambient. 6 Specify two-digit heater kW size to complete model number. ' R-410A refrigerant used in all systems. e All units meet or exceed ASHRAE 90.1 standards. 9 All units less than 250 volts have a Leak Current Detector Interrupter(LCD!)power cord and meet UL 484 standards. 10 Refer to electric heat performance data for total MCA and recommended overcurrent protection.Amps and Watts notation refers to compressor only. Specifications and Accessories Catalog 9 *duct Specifications: HEH Models — Reverse-Cycle Heating Perfor - - ce HEATING i HEH073H HEH074H HEH093H HEH094H HEH123H HEH324H CAPACITY' **AXXX **AXXX **AXXX **AXXX **AXXX `"AXXX Voltage 1,3 230/2•. 265 230/208 265 230/208 265 BTU/h s 6,800/6,800 6800 8,300/8,100 8300 11,50* 1,300 11400 Amps 70 4.1/4.1 ' . 4.7/4.7 4.2 6.2/6.2 5.4 Watts10 600/600 600 735/715 735 1,085/1,065 1075 COP 5 3.3/3.3 3.3 3.3/3.3 .3 3.1/3.2 3.1 CFM(Dry) 360 360 3 : 370 370 370 NOTES ' All 265-volt models must use an Amana*brand sub-base(PTSB4**E . an Amana®bra • •and-wire kit(PTPWHWK4). ' Minimum branch circuit ampacity ratings conform to the Nati.•: Electric Code;however,to : codes should apply. 3 Minimum voltage on 230/208-volt models is 197 volts;m• ' urn is 253 volts.Minimum voltage on-- -volt models is 239 volts;maximum is 292 volts. 4 Overcurrent protection for all units without el•- -ic heaters is 15 amps.Overcurrent protection on 265-volt ••els must be cartridge-style time-delay fuses ' uded and factory-installed on all Amana0 brand 265-volt chassis). 5 Heating capacity and efficiency bas=-on unit operation without condensate pump;unit automatically switches to elec ' heat at approximately 24°F outdoor ambient. 5 Specify two-digit heater. .size to complete model number. ' R-410A refrigerant -.in all systems. 8 All units meet• exceed ASHRAE 90.1 standards. 9 All units - than 250 volts have a Leak Current Detector Interrupter(LCDI)power cord and meet UL 484 standards. 10 Ref' o electric heat performance data for total MCA and recommended overcurrent protection. •mps and Watts notation refers to compressor only. Product Specifications: PTH Models — Reverse-Cycle Heating Performance HEATING PTH073G PTH074G PTH093G PTH094G PTH123G PTH124G PTH153G PTH154G CAPACITY' **AXXX **AXXX **AXXX **AXXX **AXXX **AXXX **AXXX **AXXX Voltage 1.3 230M 265 230 265 230M 265 230 yy' 265 BTU/85 6,800/6,800 6,800 8,300/8,100 8,300 11,500/11,300 11,400 13,800/13,600 13,700 Amps 10 3.9/3.9 3.1 4.2/4.2 3.7 5.8/5.8 5 7.0/7.0 6.1 Watts 10 585/585 585 715/700 715 1,085/1,035 1,080 1,350/1,330 1,340 COP' 3.4/3.4 3.4 3.4/3.4 3.4 3.1/3.2 3.1 3.0/3.0 3 CFM(Dry) .370 370 360 360 370 370 ,410 410 NOTES ' All 265-volt models must use an Amana`^brand sub-base(PTSB4**E)or an Amana"brand hard-wire kit(PTPWHWK4). ] Minimum branch circuit ampacity ratings conform to the National Electric Code;however,local codes should apply. ° Minimum voltage on 230/208-volt models is 197 volts;maximum is 253 volts.Minimum voltage on 265-volt models is 239 volts;maximum is 292 volts. o Overcurrent protection for all units without electric heaters is 15 amps.Overcurrent protection on 265-volt models must be cartridge-style time-delay fuses(included and factory-installed on all Amana'brand 265-volt chassis). 5 Heating capacity and efficiency based on unit operation without condensate pump;unit automatically switches to electric heat at approximately 24°F outdoor ambient. 8 Specify two-digit heater kW size to complete model number. ' R-410A refrigerant used in all systems. 8 All units meet or exceed ASHRAE 90.1 standards. 9 All units less than 250 volts have a Leak Current Detector Interrupter(LCD!)power cord and meet UL 484 standards. 10 Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to compressor only. 14 14/1T'VV otilCifO /.)lcic.toil, Heating 8 Air Conditioning aim AMERICA'S BRAND FOR COMFORT' Accessories WALL SLEEVES S r RA DEEP SLEEVES:in several depths for All our wall sleeves have industry standard dimensions thic-r wall installations or special room of 42"wide x16'/,6"high.The WS900E,SC and INTERNAL configu tions 141/2" depth is the industry standard. Sleeves may be shipped separately to allow for installation WS9XXD1 16"to 24"in 1"i. rements Qty(48) during construction. W5928D1 ra deep , _; WS930D1 Ext. .e 30" TIIII -- l\ STANDARD-DEPTH SLEEVES WS936D1 Extr. .e •36" WS900-GS Heavy Sound Isolation Insulation Sleeve ra deep I -mal drain 1PPFP �IIVS900E Standard PTAC sleeve WS9XXD1- only for windo all WS900SC Seacoast triple protected Internal installations(DK9.!it sold 42-----__________r, �"° WS900D- Internal drain only for window-wall separately) INTERNAL installations(DK900D sold separately) OUTDOOR GRILLES STANDARD OUTDOOR GRILLE Available in stamped-aluminum or architecturally SGKO1B Single Pack louvered for application with an Amana brand WS900E wall sleeve. SGKO1TB Stonewood Beige AGK:Extruded aluminum architectural grille available with anodized aluminum finish or a baked-on paint ARCHITECTURAL OUTDOOR GRILLE Up I finish for durability.Choose from 3 stock colors or a N �� I custom color to blend with your building's exterior AGKO1CB Anodized Aluminum SGK • I' color scheme.Colors include: AGKOIDB Dark Bronze/Brown irM° "' CB(Clear Anodized),DB(Dark Brown/Bronze) 1 xAGKO1TB Stonewood Beige j TB(Stonewood Beige),WB(White), AGKO1WB Amana White AGK SB(Special/Custom Colors) QTY:(48) AGKO1SB Custom Colors or PGK:One-piece injection molded grille using a polymer PGKO1D8 Dark Bronze/Brown PGK blend of engineered thermoplastic high-impact ) strength material with chemical resistance and PGKO1TB Stonewood Beige an exterior UV protective coating. PGKO1WB Amana White Choose from 3 stock colors: DB(Dark Brown/Bronze),TB(Stonewood Beige), WB(White) CONDENSATE DRAIN KIT Qty(48) Attaches to the wall sleeve base pan for controlled - DK900D Condensate Drain Kit (use with WS900E) DK90oD internal or external disposal of condensate. Ce.idei.3et.Drei„Ka •D1E98Oi-B �e� % LOW-VOLTAGE WIRE HARNESS KIT(NOT SHOWN) I ,,,__ _ ____ PWI IIf9�6 For quick connections of the remote, or wired, thermostats,wired EMS,or front desk with jumpers and connectors. W QTY:(5) REMOTE ESCUTCHEON KIT(NOT SHOWN) Each"B"kit contains 80 wires and wire nuts, Optional kit for use with units controlled via a wired, REK1OB Remote Escutcheon Kit enough to attach a thermostat and one remote thermostat.Covers control touch-pad for wired (10-pack) additional accessory to 10 PTAC units.Wires thermostat installations. come in assorted colors for easy attachment. REK10A 11—,et.[3,.t,t�11,..,,,PLt... Each"A"kit contains 10 Escutcheon plates only. Specifications and Accessories Catalog 15 Accessories (cont.) Thermostats The following thermostats offer remote control.Any thermostat other than those listed must be submitted to Goodman Company,L.P., for approval prior to use. MODEL# HEAT STAGES COOL STAGES FAN SPEED #OF WIRES TEMP BACKLIT DISPLAY TYPE SHAPE& CONNECTION REQUIRED LIMITING ORIENTATION 2246002 1 1 1 5 No Yes Digital Manual Rect./Horiz. Wired 2246007 ' - 2 2 1 7 Yes Yes Digital Auto-Change Rect./Horiz. Wired Qty(48) NWT-AMRi 2 2 2 7 Yes Yes Digital Manual Square/ Wired — z Vertical PHWT-A200 [11 2 2 2 7 Yes Yes Digital Programmable/ Square/ Wired Auto-Change Vertical DS01E* iv,, 2 2 2 0 Yes Yes Digital Manual Rect./Horiz. Wireless DSA01 NM *Battery powered,but has optional hard wire capability.Requires DTO1G Antennae for operation HY*.ONIC HEAT Klr Hydronic Heat Kit: Hydronic Heat Kit:Top View Add-o its fit all units allowing the addition of .ronic Side View water or h,•ronic steam heat to cooling and h-. ing units. . _ _ .: . The kits feat. - left- or right-hand pipin:. Unit retains j complete service . cess with a kit inst. -d. Unit must be -- - connected to and ope: ed by a wall --rmostat. Hydronic Heat Kit:Right View HWKO3B HydronicWat- -R-22 - -— HVKO3B HydronicS -•m -R-22 i 1 HWKO3E Hydro ' aterKit-• ' OA HVKO3E Hy. onic Steam Kit-R-41.• r J 18 ww14/.001CM0/J{C1C.COM Heating$Air Conditioning ana® AMERICA'S BRAND FOR COMFORT AMANA PHWT A200 THERMOSTAT 3) SAFETY INFORMATION • This thermostat is for LOW voltage applications only. ( • Turn OFF electricity to all heating and cooling i 1 components. fr • All wiring must conform to applicable local "EAT and national building and electrical codes and COOL ordinances. f� X A _ 4) TO REMOVE EXISTING THERMOSTAT 1. Write down the letters printed near each wire Ir terminal that is used,and the color of each wire it i %I '1-- -,'',,,`-t-.4",, 4 is connected to;self-adhesive wire labels are also C ` ' �� �� enclosed. Xt . . 'N l' `k OF ' 2. Carefully remove wires from existing thermostat „1 • ' ��tri 1,7 and bend so they cannot fall back into wall or touch each other. 3. Remove existing thermostat base from the wall. 1'. Alia E 5)TO INSTALL NEW THERMOSTAT 1. Mount the thermostat on an inside wall about 1) DESCRIPTION AND COMPATIBILITY five feet above the floor in an area that has good circulation, but is not directly affected by a vent The Amana PHWT-A200 is a programmable electronic thermostat,which can be used with the following or duct. heating/cooling applications: 2. If painting or construction is still ongoing,cover the thermostat completely or wait until work is • Cooling/Conventional PTAC Units(PTC)with or complete before mounting thermostat. without Electric Heat 3. If new mounting holes are needed, mark the • Heat Pump PTAC Units(PTH or HEH)with or placement of the new mounting holes through without Electric Heat the thermostat base. Using a 3/16"drill bit, drill the holes you have marked and insert the 2) SPECIFICATIONS supplied wall anchors. 4. Feed the wires through the wire opening in the • Input Voltage: 19 to 30 VAC base and use supplied screws to mount base to • Output Rating: Max. 1.5A per terminal(3A total) the wall. • Temperature Control:45°F to 90°F(7°C to 32°C) 5. Using Section 7)WIRING DIAGRAMS,wire each • Temperature Accuracy:±1°F(±0.5°C) I terminal on the new thermostat base. Ensure that • Wire Terminals: I the bare end is fully seated into the connector, C 24 VAC Common I then tighten securely. Pull gently on wires to GL Fan LOW Speed ensure they are secure. GH Fan HIGH Speed 6. Place thermostat front back onto the base. W2 2nd Stage or Auxiliary Heating Signal 7. Restore power back to heating and cooling W1 1st Stage Heating Signal components and thermostat. Y Cooling Signal 8. See Section 8) INSTALLER SETTINGS MENU,to R 24 VAC Hot adjust the required settings needed for each B/O Reversing Valve system type. 6) FRONT PANEL CONTROLS THERMOSTAT SYSTEM MODE BUTTON: UP AND DOWN BUTTONS: X1--* System Mode Button l I;� I (A UP button DOWN button coa X COOL I x 1 Press System Mode button until desired mode is underlined,after 2 seconds with no button press the UP/DOWN=used for raising or lowering the target set underlined system mode is entered. temperature and selecting user options and settings in the display screen. AUTO=automatically selects heat/cool mode as needed (may be disabled in installer settings) The temperature that is shown at all times in normal OFF=thermostat stops all heating or cooling functions operation is the target set temperature. HEAT=thermostat permits heating operation COOL=thermostat permits cooling operation To view current ambient room temperature while in Auto,Heat,or Cool mode,perform a single press of BOTH the Up and Down buttons at the same time. THERMOSTAT FAN BUTTON: Note:to adjust the target set temperature, first ensure that the thermostat is in either Auto,Heat, or Cool I ( ,) mode,and press either the Up or Down buttons until (� the desired target temperature is reached. Presses to I (r, the Up or Down buttons will have no effect when the thermostat is in Off mode. coop x► -*- Fan Mode Button Press Fan Mode button until desired mode is underlined,after 2 seconds with no button press the underlined fan mode is entered. FAN AUTO=fan operates in low or high speed mode as needed during a call for heating or cooling activation only. FAN LOW=fan operates continuously in LOW speed, with the heating or cooling components cycling on and off in the background as needed. FAN HIGH=fan operates continuously in HIGH speed, with the heating or cooling components cycling on and off in the background as needed. 7)WIRING DIAGRAMS UP TO 2H/1C HEAT PUMP APPLICATIONS: UP TO 1H/1C CONVENTIONAL APPLICATIONS: (AMANA PTH&HEH PTAC MODELS): (AMANA PTC PTAC MODELS) **see note 1 B/0 • HP Reversing Valve ) B/0 • NOT USED R •--24V Power R -24V Power y • ( Heat Pump Compressor ) y • C A/C Cooling ) A/1 • NOT USED *see note 1 W 1 • ( Heating Stage-1 )**see note 2 \/V2 • ( Auxiliary/Emerg Heat ) *see note 2 W2 • NOT USED GH • (Blower Fan(High Speed) ) *seenote3 GH • ( Blower Fan(High Speed) )**seenote 3 G L • ( Blower Fan(Low Speed) ) G L • ( Blower Fan(Low Speed) ) C •-24V Common C •-24V Common AMANA PHWT-A200 AMANA PHWT-A200 THERMOSTAT THERMOSTAT *HEAT PUMP WIRING DIAGRAM NOTES: **CONVENTIONAL WIRING DIAGRAM NOTES: • Note 1:When configured for Heat Pump operation, • Note 1: For Conventional(cooling) PTAC units, the"Y"terminal will be called for during both cooling Installer Settings menu 06(System Type) must be set and first-stage heating operation. Do not connect to"Con". any wires to the"Wi"terminal. • Note 2: If connecting to a Conventional PTAC unit • Note 2:The"W2"terminal is used to call for Electric/ without electric heat,the W1 and W2 wire terminals Auxiliary heat. If your Heat Pump PTAC does not have will not be used and Installer Settings menu 03 Electric heat,then the"W2"terminal should not (Available Modes)should be set to"04:Cool Only" be used and Installer Settings menu 10(Aux.Stage • Note 3: For PTAC units with only one fan speed Offset)should be set to"OFF". (single"G"fan wire),use the"GL"terminal for wiring • Note 3: For PTAC units with only one fan speed and Installer Settings menu Item 12(High Fan) must (single"G"fan wire), use the"GL"terminal for wiring be set to"OFF". and Installer Settings menu 12(High Fan) must be set to "OFF". 8) INSTALLER SETTINGS SOFTWARE CONFIGURATION SETTINGS NOTE:Waiting 1-Minute with no button presses will exit MENU# SETTING OPTIONS the installer settings menu with all items saved as they 01 Scale F,C were last shown on the display screen. 02 Temp.Calibration Zero,-5F to+5F (-3C to+3C) TO ENTER INSTALLER SETTINGS MENU: 03 Available Modes 01:Heat,Cool,Auto 02:Heat,Cool I rim! 11:Z1 03:Heat Only 04:Cool Only With thermostat powered, 04 Max.Heat 60F to 90F(80F) I Limp A press System Mode button (16C to 32C) Iuntil OFF is underlined. 05 Min.Cool 6OF to 8OF(65F) 1 After OFF mode is confirmed, (16C to 27C) press and hold BOTH the Up 06 System Type HP=Heat Pump it and Down buttons for at least Con=Conventional 5 seconds until the screen 07 HP Valve Type B:Valve on in Heat changes. 0:Valve on in Cool 08 Auto Dead-Band 2.0F(1.11C) 3.OF(1.67C) TO CHANGE AN ENTRY: 4.0F(2.22C) 5.0F(2.78C) r 09 Swing/ ±0.25F (±0.14C) '1 I Temp.Differential ±0.50F (±0.28C) ±1.00F ±0.56C Use the Up or Down buttons ±2.25F (±1.25C) A to change the setting option. 10 Aux.Stage Offset Off (for Heat Pumps only) 1:1.OF((0.5C)) l Y2:2.OF(1.0C) 3:3.OF 1.5C 4:4.0F(2.0C) ' x 5:5.0F(2.5C) no- 12 High Fan On:Available Off:Disabled TO ADVANCE TO THE NEXT MENU ITEM: 13 Programming Off:Manual On:Programmable 14 Clock Format 12:AM/PM - • •"` (see note#1) 24:24 Hr.Military yr. 15 Periods per/Day 4:4-Periods (see note#1) 2:2-Periods Press the Mode button one 1:1-Period time to advance to the next 16 Auto Daylight On:Auto DST item in the menu. Savings(see note#1) Off:Manual moi. (Sc 17 Backlight Always On Off=Turn off 10 sec On=Always On 18 Use default set temp. ON:Uses default acs � after mode change temps (see note#2) OFF:Use last temp per mode TO RETURN TO THE MAIN THERMOSTAT SCREEN: 19 Default heat mode set 70F(21C) temp(see note#2) 60F to max heat set temp HEAT 1Irj 20 Default cool mode set 74F(23C) temp(see note#2) 80F to min cool set temp A. 98 Compressor No=Delays Remain While at the last menu item, Protection Bypass Yes=Suspend Delay press the System Mode 99 RESET No=Save and Exit button one more time to exit Yes=Full Reset f \_-j k the Installer Settings menu. NOTES:(#1)For Programmable operation only. (#2)For Non-Programmable operation only. eo- SETTING DESCRIPTIONS: 9)AUTOMATIC DAYLIGHT SAVINGS TIME 01 (Scale):Displayed temperatures shown in F/C degrees. By default,the thermostat will automatically adjust 02(Temp.Calibration):Gives user flexibility to adjust the clock for Daylight Savings.This can be disabled by the perceived measured temperature that is used for changing the Auto Daylight Savings(setting 16) option thermal control. in the installer menu. 03(Available Modes):Determines which system modes are available to the user when pressing the System Mode button. 10) SET CLOCK AND TEMPERATURE PROGRAM 04(Max.Heat):Sets the maximum temperature that a user can adjust the target temperature to for heating. SCHEDULE 05(Min.Cool):Sets the minimum temperature that a user NOTE:Waiting 1-Minute with no button presses will exit can adjust the target temperature to for cooling. the settings menu, with all items saved as they were last 06(System Type):Selects the type of heating/cooling shown on the display screen. equipment that is present in the system. 07(Heat Pump Valve Type):Determines if the combined With thermostat powered, 0/B terminal operates as"B"(energized while in Heat press System Mode button mode),or as"0"(energized while in Cool mode). until OFF is underlined. 08(Auto Dead-Band):Determines the amount of After OFF mode is temperature separation needed for Auto Mode to EE confirmed,press and change between Heat and Cool modes i J hold BOTH the Menu and 09(Swing/Temp.Differential):Determines how wide or • Up buttons for at least 5 narrow the temperature control band is between cut-in � seconds until the screen and cut-out. r—t changes. 10(Aux.Stage Offset):Sets the number of degrees from the setpoint,that will cause the second heat stage to turn Use Up or Down buttons to move the underline with on. the selection item you want to adjust and then press 12(High Fan):Permits or prevents the capability for using the System Mode button one time to enter selection. the high-speed fan mode. 13(Programming):Determines if the thermostat acts as a CLOCK DIGITS=adjusts the current real-time clock. programmable thermostat with period changes during HEAT=programming area to adjust the heating the day,or manual operation only. temperature set points for each day and period. 14(Clock Format):Determines the appearance and usage of COOL=programming area to adjust the cooling the clock digits,either AM and PM,or 24hr military time. temperature set points for each day and period. 15(Periods per/Day):Sets the quantity of temperature EXIT?=exits the clock and programming menu and periods used per programming day. returns thermostat to the main home screen in Off mode. 16(Auto Daylight Savings):Determines if the thermostat automatically adjusts the clock for Daylight Savings Time or requires manual adjustment in the spring and 11)ADJUSTING THE REAL-TIME CLOCK fall. 17(Backlight Always On):Allows the display backlight to • Upon entering clock settings,the blinking hour remain on constantly or turn off automatically after 10 digits are adjusted using the Up or Down buttons. seconds. Continue to press either Up or Down to cycle all 18(Set Temp After Mode Change):Determines if the the way around and swap between AM and PM as thermostat recalls the last used set temperature per needed. mode or uses a default set temperature when the mode • Press the Menu button to advance to setting the is changed manually. minutes,using the Up/Down buttons to change 19(Default Heat Mode Set Temp):Determines the default value. set temperature that is used when first selecting heat • Press the Menu button to advance to setting the mode. year,using the Up/Down buttons to change value. 20(Default Cool Mode Set Temp):Determines the default • Press the Menu button to advance to setting the set temperature that is used when first selecting cool month,using the Up/Down buttons to change value. mode. • Press the Menu button to advance to setting the day, 98(Delay Bypass):Contractor/Installer mode,turns off using the Up/Down buttons to change value. the compressor delays for testing the system;returns automatically to normal operation after 5 minutes. 99(RESET):Returns all settings back to factory defaults. 12)ADJUSTING THE HEAT OR COOL 13) ENTERING EMERGENCY HEAT MODE TEMPERATURE PROGRAM (HP UNITS ONLY) • Each period ends at the start time of the next • While in regular HEAT mode,press and hold BOTH upcoming period. the Mode and Fan buttons for at least 5 seconds, NOTE: If configured to use only 2 periods,only DAY until the screen changes. The thermostat will show and NIGHT will be used,and the MORN and EVEN HEAT with "E"to confirm Emergency Heat mode. periods will not be used or visible. If you use 1 This will use only the W2 wire terminal as the heating period and 7 day programming,then thermostat source and will not call for compressor heating. will reset to the desired set temperature at the same • To return to normal heating mode, press and time each day. hold BOTH the Mode and Fan buttons for at least • Upon entering either HEAT or COOL programming 5 seconds until the screen changes. The"E"will sections,choose which day[s]you would like to disappear and only show"HEAT"to confirm regular adjust with the same settings(i.e.all weekdays Heat mode. together,or each day separately). Use the Up/Down buttons to scroll through the blinking days and press the Menu button to select each day with an 14) SETTING A KEYPAD/ FRONT PANEL LOCKOUT underline. Once all desired days are selected,move • While in any normal operating mode except OFF,a blinking selection to PROG?and press the Menu keypad lockout can be introduced which will prevent button to proceed. any mode change,fan change or temperature • Adjust the start time of the first program period adjustment from being made by the user. Even when using Up/Down buttons and press the Menu button locked,any button press will illuminate the display to advance. Adjust the start time of the first program backlight. period using Up/Down buttons and press the Menu • To activate(and deactivate)the keypad lockout, button to advance. press and hold BOTH the MODE and FAN buttons • Use this same step-by-step process to adjust the for at least 5 seconds. When the keypad is locked, remaining periods for the day or group of days being a padlock will appear in the lower left corner of the adjusted. display. • When all periods have been adjusted,the screen will blink EXIT? If you are not yet done with adjusting other days,you can use Up/Down to select other days with an underline just like above and repeat the same process. If you are done,press the Menu button to exit the programming menu.These steps performed apply only to the mode you have just programmed. If necessary, please repeat programming process for alternative mode. • If you are all done performing setting changes,move the underline to EXIT?and press the Menu button to return to the main home screen. 4-Periods 2-Periods 1-Period MORN Time 6:00 AM HEAT 70F COOL 78F DAY Time 8:00 AM 8:00 AM 10:00 AM HEAT 62F 70F 70F COOL 82F 74F 74F EVEN Time 6:00 PM HEAT 70F COOL 78F NIGHT Time 10:00 PM 6:00 PM HEAT 62F 62F COOL 75F 82F 53609-17 Heating B Air Conditioning ana AMERICA'S BRAND FOR COMFORT' Framing for Accessory Wall Sleeve (WS9XX) FASTENING WALL SLEEVE f1 When installed in an opening,the Wall Sleeve must be horizontally level(side-to-side)and pitched 1/4 bubble (, Alternative to the outside. Fastening Method (Field Supplied) (NOTE:To ensure unit's maximum efficiency, DO NOT over-or under-pitch.) INSTALLATION NOTES V; 'Wood Screw 1. If Sub-base(PTSB***E)is installed,allow minimum Mounting I ' �//Toggle Bolt 31/4"height clearance and maximum 5"height Holes �1 • Expansion clearance between wall sleeve and floor;allow (Drilled by ��( /Anchor Bolt minimum 23/4"protrusion from a finished wall. Installer) I ` Qr See Note 4 if using hydronic units. 2. Drain Kit(DK900D)shipped separately.Can be S mounted either right side,left side or bottom of ,IJ Plastic crews sleeve.If mounted to bottom of sleeve,allow � Anchor 2"height clearance from floor to bottom of sleeve. 3. For UL approval,265V units must use Amana`brand Wall Sleeve must extend a minimum of 1/4"beyond outside wall to allow for Sub-base(PTSB"'E)orAmana`brand Hard Wire proper caulking. Kit(PSHWO4A).Overcurrent protection on 265V units must be by cartridge-style time delay fuses,which are included and factory-installed on the Amana' brand 265V chassis. JACK STUDS 4. If Hydronic Kit(HWK03 or HVK03)is installed, Wall Sleeve must extend exactly 3"into the room '1111 HEADER-4"x 4"OR from the finished interior wall.If using the Amana` MAIN STUD '‘‘1411140611. DOUBLE 2"x 4"ON EDGE brand Sub-base(PTSB***E),only the minimum ' f 3Y4"height clearance between wall sleeve and floor 11161/4" is permissible.Unit must also be operated with a MIN \'I, remote-mounted thermostat. `1ADJUST FRAMING TO 5. If Duct Kit(MDK"')is installed,allow a minimum of JiIi ', �• SECURE THIS DIMENSION 23/8"into the room from the finished interior wall. `I'1 JACK STUD I CRIPPLE ` FINISHED FLOOR 1�- SUB-FLOOR � Wall sleeve opening height should be squared with H=161/4" wall sleeve opening width. W=421/4" gip&rili;aliori,a1:i P'rt/Ori C•,l;,lc,f-_ 21 Heating&Air Conditioning ana AMERICA'S BRAND FOR COMFORT' A legacy of comfort The impeccable reputation of an American original Amana heating and cooling systems are a part of the enduring legacy of one of America's most recognized and respected brands.Originating eight decades ago in Amana,Iowa,the brand is synonymous with long-last- ing,premium-quality products—from home appliances to heating and air conditioning equipment. Chances are,you and generations before you have enjoyed the dependable performance and longevity the Amana brand continues to deliver. **American tEOPRIDE Proudly Assembled in Texas and Tennessee NAM o. remNAM CERTIFIED° COMPANY WITH COMPANY WITH PROUDLY ENVIRONMENTAL SYSTEM QUALITY SYSTEM U ASSEMBLED IN C US CERTIFIED BY DNV GL CERTIFIED BY DNV GL < THE USA FOR OVER Limp =ISO 14001= =ISO 9001= d *��* ■�i CERTIFIED' �ntertek sw I YEARS Call your Amana brand PTAC sales representative at 800-647-2982 for complete details. Before purchasing this appliance,read important information about its estimated annual energy consumption,yearly operating cost,or energy efficiency rating that is available from your retailer. www.amana-ptac.com MC-DPTAC 12-17 Our continuing commitment to quality products may mean a change in specifications without notice.d 201E Goodman Company,L.P. Supersedes 4-16 Amana is a registered trademark of Maytag Corporation or its related companies and is used under license to Goodman Company,L.P., Houston,TX,USA.All rights reserved. PTHC PWHKO1B Installation Instructions Wire Harness Kit Description The PTAC Wire Harness kit provides connection from the 14-pin terminal strip on the PTAC control board to the following board features: Emergency Hydronic Heat* Load Shedding* Front Desk Control* Transfer Fan (relay must be manufacturer-approved and have a DC low voltage coil) Remote Thermostat (must be manufacturer-approved) The kit includes a 14-pin female housing with 14 jumper wires and 14 wire nuts. The installation and servicing of this equipment should be performed by qualified,experienced technicians. *If other than a "thy switch"is used in connecting these features, consult manufacturer before proceeding. / tl i 11 1111t10 ° -..k.- C1°11° 0 ri 0 0 %-111: r3a0 a *Note: Each PTHP unit will already have the pin connector with TF(-)(GRAY w/ B (BLUE) the unit. Each unit STRIPES) C(BLACK) .' needs (2) wires that e TF(+)(GRAY) connect to the PTHP /,." - W2(WHITE)EH (WHITE w/ HITE) STRIPES) unit to terminals IN1 FDI (ORANGE) R(RED) or IN2 then to the Z. Corn Terminal. Which FD2(ORANGE) IN (RED W/ is then wired in series Y (YELLOW) STRIPES) back to the board.* GL(GREEN GH(GREEN W/ __ LS(YELLOW W/ STRIPES) STRIPES) j Due to policy of continual product improvements, the right is reserved to change specifications and design without notice. December 2000 20319102 INSTALLATION A WARNING a WARNING Disconnect electrical power source before All wiring must comply with applicable wiring the unit. Failure to do so may result local and national codes. Type and location in injury or death from electrical shock. of fused disconnect switch(es) must The unit"OFF"switch does not disconnect comply with all applicable codes. all power to the unit. 1. Disconnect power and remove the front panel per unit installation instructions. 2. Remove 14-pin female housing from control board.* W a _, o o I` I� U CC 0 3 >- CO 0 Using Table 1 and Figure 1 as guides, choose the r J feature desired and insert the proper jumper wire into - theappropriateslotonthehousing. Ensure the jumper I _ ,-E121,F ,E5111 wires are oriented as shown in Figure 2. Re-install the 14-pin housing. Ensure housing faces Figure 1 the direction shown in Figure 1. NOTE: Only load wires intended for installation. Extra Feature Pins Used wires can be used to connect other PTAC boards. One PWHKO1 B kit can be used for multiple boards. Emergency Hydronic Heat EH,IN 3. Connect the kit wiring to the field wiring using the wire Load Shedding LS, IN nuts provided. Route the kit wiring as shown in Figure 3. Front Desk Control FD1, FD2 Do not run wires through basepan or wall sleeve. Transfer Fan TF(-),TF(+) Ate, Remote Thermostat C, R,GL,W2,Y/W 1, B,GH rRR m Table 1 1 . J' IY I � � il 15111 . 1111111. i.. Figure 2 44 ,�4 1 a .1 444 4 -\ Route low voltage wire as shown above. No holes are permitted in chassis ,/--- basepan or walisleeve when routing low voltage Figure 3 wire. *If a female housing is not present on the control board,use the housing supplied with this kit. 2