Report 18S120fp-d0/9�
12 it,7s ) ♦3ZAJD41/e
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
I, 1NlAS JAVA , am the general contractor or the owner-builder
at the following address:
Site Address: 122 01- SW ISV4 J
City: 0
Permit#: M ST- 2 I g OL G
Subdivision/Lot#: #
and/or
Map and Tax Lot#:
To conform with the 2017 Oregon Residential Specialty Code (ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
/ The ground surface of the under-floor space is covered by a Class I vapor retarder or
other approved materials,with
Joints lapped 12 inches at seams and
Extending up the foundation walls 12 inches.
Signature: Date: 611- 2019
General Contr tor .r • e -:u. der
I:\Bui lding\Form\RES-Mo istureBarricrAcknowledgemen t_022018
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I, 11\X'A PcS JA-Y-0 , am the general contractor or the owner-builder
at the following address:
Site Address: 2_301. sw 15z:A
City: -c-t e--- 5R-22,3
Permit#: MST- lot a-oo\ C
Subdivision/Lot#: U.*
and/or
Map and Tax Lot#:
To conform with the 2017 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: Date: O 2016
General Contractor or er-Bui dH der
I
I:\Building\Form\RES-Moi stureContentAcknowledgement_022018
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: M S-` 20 I g_NA 5c Jurisdiction:
Site Address: 2-80-+ sw 13/4 1°J(, , o 51-7,2-3 1-Z
Subdivision/Lot#: � l
and/or
Map and Tax Lot#:
By my signature below, I certify that all of the permanently installed lighting fixtures in the
above mentioned building contain high-efficacy lamps. Screw-in compact fluorescent and LED
lamps comply with this requirement. (Oregon Residential Specialty Code N1107.2)1
Signature: / Date: 01 9_00
Owner/Gene al Con -:cto A. • ized Agent
Print Name: 1-7‘CAA 5 3-A Ko
ORSC Section N1107.2.High-efficacy lamps. All permanently installed lighting fixtures shall contain high-
efficacy lamps. Screw-in compact fluorescent and LED lamps comply with this requirement.
The building official shall be notified in writing at the final inspection that the permanently installed lighting fixtures
have met this requirement.
Exception: Two permanently installed lighting fixtures are not required to have high-efficacy lamps.
I:\Building\Forms\RES-HighEfficiencyLightingAcknowledgement 0220 18
/f5Ta0l8 - o /c?
0 .
„ , , .
E R I I E I
Building Performance, Moisture Testing&Structural Drying
Duct Leakage Test
(Duct Blast Test)
Test Type: X Total Leakage Pressurization Test Leakage to Outside Pressurization Test
Builder/Owner: Heidi Csokas
Subdivision/Lot#:
Address: 12807 SW 132nd Ave Tigard, OR
Total Square Feet per Floor
Floor/Level SqFt
1st/Main Level 1,835
2nd Level 1,593
Addional Level/Basement
Total Square Feet 3,428
Max Allowable Leakage= 206 CMF at 25 Pa
Test Result: 194 CMF at 25 Pa
X Meets Oregon Dept of Energy Performance Standards
Home Certified, Inc.
PO Box 2063
Lake Oswego,OR 97035
OR CCB 158005 WA LIC#H2OMECI946KU
Phone:(866)379-4674
poge4 9/20/2019
Chris Jones Date
503-869-1172
BPI ID#5013958