Loading...
Plans (2) RECEIVED Building Plans for City of Tigard Building Permit Application OCT 7 2019 CITY OF TIGARD Customer: The Fountains at Summerfield condominiums HOA BUILDING DIVISION 15685 SW 116th Ave., #105 Tigard, OR 97224 Contact - Paul Brock, 858-212-9105, pbrock987Pgmail.com Contractor: Jon Erickson, 503-730-9220 ion.eveniobs(agmail.com CCB 162397 PRICE Copy Scope of Work—Repair Decks CITY OF TIGARD • Replace perimeter joists with PT REVIEWED FOR CODE COMPLIANCE • Repair joist and soffit dry rot Approved ) I • se-coat decK OTC: [ I • Replace 42" guardrail and infill to comply with Permit#• 43v p.QQ7 ) - 00 a R 3 IBC multi-family code Address:• JS 4as- Sw )C9 Tt Suite#: J o ) Br Date: )0- )y. � l File Name: Fountains Deck Permit Plans REVISED.pptx VALIDITY OF PERMIT THE ISSUANCE OF A PERMIT BASED ON CONSTRUCTION DOCUMENTS AND OTHER DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM REQUIRING THE CORRECTION OF ERRORS.OSSC 105.4 10/6/19 Fountains at Summerfield - Deck Building Plans 1 Typical Deck Construction and Size — 102 SF 114.5" Brick Col. 15x11.5 F-- Imbedded 6x6 PT ,E 4x4 PT Posts A L" 2 x 8 PT blocking between joists attached with Three 16D 3-1/2"n HDG >< '< Ref: 2014 Oregon Structural 43" 15" 56.5" Specialty Code —Table 2304.9.1-29 2"x8" Joists 16" OC Blocking supports Simpson Rim joist attached to / Tension Ties DTT2Z. Two lateral joists with El / DTT2Z brackets required for I Three 16D 3-1/2"n HDGposts in this position. See Beam" 6"x10" Simpson Wood Connection Ref: 2014 Oregon Connectors 2018-18 Deck Structural Specialty Tension Ties— page 337 Code—Table °i 2304.9.1-29 House—Brick exterior 43" Scale— 12"/increment V1— IMIN• 11••••••11M1 10111010•11•11111111 10/6/19 Fountains at Summerfield - Deck Building Plans 2 Water Penetration Remediation — Cross Section Posts—4x4 PT Flashing 2" x 3" Resurfacing material 3/4" exterior plywood decking 'o Co N `�-- Hardi-plank Fascia9.25" x .25". Applied with exterior adhesive and secured with post bolts. Wicking protection for soffit provided by%" extension. Pre-paint before adding flashing %" plywood soffit Scale— 1" increment 10/6/19 Fountains at Summerfield - Deck Building Plans 3 r .., Guard Rail Post — Simpson Tension Ties Posts—4x4 PT 414 Simpson DDT2Z Attach to lateral foist with 'N\ Attach 8 SDS 1.5" screws %" x 6" Machine BoltDTT2Z supports 1800 lb. HDG with nuts and pp tension load. Meets IBC washers Code for multi-family deck 00 'o guardrails. x, E Refer to attached Simpson catalog - Deck Tension Ties Lateral Joist page 337 Also refer to Simpson code- compliant Guardrail Post Connection bulletin T-C-GRDRLPST17 Scale— 1" increment wimanarm 10/6/19 Fountains at Summerfield - Deck Building Plans 4 Typical Guardrail and Infill Section — 50" max. between posts ,--- --- Simpson Strong Drive A , giiir„,,,,, ,, ,, -,, 44 b it Wide Screw SDWS 4", IFY Railing 2 x 4 TKC o Cap Rail—Trex 2 3/8"TL. Two per etolz end, three in mid span attached to .-,•tt, tit ..' 'tt $$ 1 4,,,, '.,,,,,, ,-, Railing with [ exterior adhesive. Railing Support 4,7; cyi [ . r 2 x 4 TKC III 0 Attached to 0 r‘i Railing and tcr tti It -2 kt t. .,t,„ v 4 4, 14 4, .}. 4 ,J, ,,,,. '10 Installation of t:t x 0 PA 4, , balasters and rails Posts with ' i- '',Zit Fl It' , i 4 I .T,4, 41 ' 3, adhesive and tt,g,4„ "t:. tt't, , tt, 41 qt f,' iva f, k K4 *$ '4. 4 1 `;' per mfg installation Simpson94 1 instructions. Strong Drive Wide Screw 1 1 SDWS 4'', Railing 2 x 4 TKC Railing Infill - 2 3/8"TL. 1 DecKorator aluminum V ____ 2.75" space balaster 3/4" x 32". e Spacing 3.75" DecKorator Scale 1" increments 41 CodeCompliance Research Report Iiiiiiiiiiiii CCRR-0161 10/6/19 Fountains at Summerfield - Deck Building Plans 5 of 5