Loading...
Plans PROJECT SUMMARY 4FF%CE COPY PROJECT DIRECTORY VICINITY MAP ® . 3 , I L PROJECT ADDRESS 11555 SW DURHAM ROAD I TIGARD, OR 197224 OWNER ARCHITECT ARCHITECTURE, LLC styLEGAL DESCRIPTION R2081779-1998-128 PARTITION PLAT L�O�T 1 HARSCH INVESTMENT PROPERTIES MELYNDA RETALLACK �GARD �`` "'}� 2808 NE MLK, ste G YEAR BUILT 1951 3 INK:BUILT ARCHITECTURE PROJECT SITE I' 'L.D FOR CODE C() I',--1` NCE 1620 SW TAYLOR ST, STE 300 2808 NE MLK BLVD, STE G 544 eoq� k�Fpland �,,_ PORTLAND, OR 97212 SITE AREA 4.67 ACRES \� I PORTLAND, OR 97205 PORTLAND OR 97212 ,.,r �o) �.$ 503.454.6793 A: 'N ZONING C G I 1 • +503.242.2900 +1.503.701.5277 ..4- inkbuiltdesign.com CONSTRUCTION TYPE IIIB FULLY FIRE SPRINKURED c , ) GENERAL CONTRACTOR 4P° )3 D.9 e OCCUPANCY B(D6), M(B2) 11.,c-4S 1'>v l^he..w\-,,,r• PACIFIC CREST STRUCTURES INC. Y SW DURHAM ROAD ` SAD. f�' .:4 FLOORS/HEIGHT 1 STORY • CCB#66995 g ,a.. w "/ �, ';. C te: ii aE-, c4 17750 SW UPPER BOONES FERRY RD., #190 Q � AREA OF WORK 1,530 SF(B2)+2,148 SF(D6)=3.678 SF To} , DURHAM, OR 97224 � r +1.503.968.8949 (,� ... ,rss o SW Tuan L Q villa Or v` SCOPE OF WORK DESCRIPTION: RE V DEMO WORK TO REMOVE WALLS AND PLUMBING FIXTURES. 0. sw Kent St 4 •- s L, �* ' . MODIFY EXISTING RESTROOMS IN B2. APPLICABLE CODES + REGULATIONS NOTE: PLANS PRINT FULL SIZE AT 11X17 NO V 1 9 2019 SEPARATE PERMITS ZONING+DEVELOPMENT CITY OF TIGARD-TITLE 18 COMM. DEV. CODE SHEET INDEX 'C`I`l O, T..,`p0 BUILDING CODE 2014 OREGON STRUCTURAL SPECIALTY CODE , _ ING DIVIS,"s ,, ELECTRICAL SUBMITTED UNDER SEPARATE COVER MECHANICAL CODE 2014 OREGON MECHANICAL SPECIALTY CODE ARCHITECTURAL m FIRE SPRINKLER -SUBMITTED UNDER SEPARATE COVER MECHANICAL-SUBMITTED UNDER SEPARATE COVER PLUMBING CODE 2017 OREGON PLUMBING SPECIALTY CODE A0.00 PROJECT INFO AND VICINITY MAP PLUMBING-SUBMITTED UNDER SEPARATE COVER A1.00 SITE PLAN AND CODE ANALYSIS U..1 ELECTRICAL CODE 2017 OREGON ELECTRICAL SPECIALTY CODE A2.10 EXISTING AND DEMO PLANS - LT ACCESSIBILITY STANDARDS 2014 OSSC, ICC/ANSI 117.1 2009 A2.20 NEW WCYAK PLANS = H � PROJECT GENERAL NOTES A4.00 CEILING AND WALL DETAILS Cr) o W A5.00 ADA DETAILS- DOORS AND CLEARANCES I 0- 1. DRAWINGS ARE DIAGRAMMATIC AND DO NOT NECESSARILY DEPICT ALL MATERIALS IN ALL INSTANCES. A5.01 ADA DETAILS-PLUMBNG FIXT.AND MOUNTING HTS. r: Q 2. DO NOT SCALE DRAWINGS;WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. O a 3. CONTRACTOR TO VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO CONSTRUCTION AND PURCHASE OF MATERIALS.ANY VALIDITY OF PERMIT w N DISCREPANCIES BETWEEN FIELD MEASUREMENTS AND DRAWINGS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE THE ISSUANCE OF A PERMIT I Y OF TIPAor (X 2 Q ARCHITECT. BASED ON CONSTRUCTION I- _ 4. ALL DIMENSIONS ARE FROM FACE OF FRAMING OR GRID UNLESS OTHERWISE NOTED.SEE ASSEMBLIES WHERE APPLICABLE. DOCUMENTS AND OTHER Aper®ved by PanningLC) CC ff w 5. DRAWINGS REPRESENT THE FINISHED STRUCTURE,THEY DO NOT INDICATE METHOD OF CONSTRUCTION. CONTRACTOR SHALL ASSUME DATA SHALL NOT PREVENT Date: 1 t 9 z p O RESPONSIBILITY FOR DETERMINING APPROPRIATE METHOD AND SEQUENCE OF CONSTRUCTION. THE CODE OFFICIAL FROM initials: J CD 6. DETAILS NOTED AS"TYPICAL"OR"TYP"APPLY IN ALL CASES UNLESS SPECIFICALLY REFERENCED. DETAILS THAT ARE SPECIFICALLY REQUIRING THE CORRECTION J ;a,. I vii p REFERENCED SHALL TAKE PRECEDENCE OVER ALL OTHER GENERAL OR TYPICAL NOTES. OF ERRORS. OSSC 105.4 _JLi Q 7. CONTRACTOR SHALL ENSURE THAT ALL WORK IS EXECUTED IN COMPLIANCE WITH ALL GOVERNING CODES,STANDARDS AND REGULATIONS. < , C.9 8. CONTRACTOR TO COORDINATE AND PROVIDE ALL CODE REQUIRED SIGNAGE UNLESS OTHERWISE INDICATED. ABBREVIATIONS I I-= 9. PROVIDE ACCESS PANELS AS REQUIRED. LOCATION, FINISH,AND TYPE SHALL BE APPROVED BY ARCHITECT PRIOR TO OBTAINING AND AFF ABOVE FINISH FLOOR INSUL INSULATION INSTALLING. MATCH RATING TO ASSEMBLY IN WHICH THEY ARE INSTALLED AND PROVIDE SMOKE SEALS WHERE RATINGS ARE REQUIRED. AOS BOTTOM INT INTERIOR DATE: 11/01/2019 Q BO BOTTOM OF MFR MANUFACTURER 10. ALL RATED ASSEMBLIES SHALL BE CONSTRUCTED TO PREVENT THE MOVEMENT OF HOT FLAME OR GASES PER OSSC SECTION 709.6.ALL CLNG CEILING MAX MAXIMUM g2-D6 DEMO PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE FIRESTOPPED. q CNT MIN MINIMUM CL CEE CONTROL MIL METAL 11. CONTRACTOR TO PROVIDE SAFETY GLAZING AT ALL LOCATIONS REQUIRED BY CODE AND SHALL BE PERMANENTLY LABELED WITH THE CLR CLEAR NIC NOT IN CONTRACT REVISIONS MANUFACTURER'S NAME AND TEST APPROVAL INFORMATION. SEE WINDOW AND DOOR SCHEDULE. CONT CONCRETE OAE OR CONT EQUAL CONT CONTINUOUS OC ONN CENTECENTER 12. ALL MECHANICAL, ELECTRICAL,AND PLUMBING TO BE DESIGN-BUILD UNLESS OTHERWISE INDICATED. CONTRACTOR TO PROVIDE ALL DIMS DIMENSIONS OF/CI OWNER FURNISHED,CONTRACTOR INSTALLED g DOCUMENTATION INCLUDING SHOP DRAWINGS THAT ARE NECESSARY FOR CONSTRUCTION AND PERMITS. PROVIDE SYSTEM DESIGN ELEV ELEVATION OF/OI OWNER FURNISHED,OWNER INSTALLED Q EQ EQUAL OPH OPPOSITE HAND DRAWINGS TO ARCHITECT FOR REVIEW IN PRIOR TO PERMIT SUBMITTAL. (E) EXISTING PT PRESSURE TREATED EXT EXTERIOR RD ROOF DRAIN 4 01- 13. ALL SUBSITUTIONS TO BE SUBMITTED TO AND APPROVED BY THE ARCHITECT PRIOR TO CONSTRUCTION. FD FLOOR DRAIN RO ROUGH OPENING PROJECT INFO AND 14. PROVIDE SHOP DRAWINGS FOR ALL CASEWORK. VERIFY MATERIALS&PRODUCTS TO BE SUBMITTED FOR REVIEW WITH THE ARCHITECT. FE FIRE EXTINGUISHER SD SMOKE DETECTOR 15. CONTRACTOR TO KEEP AREA OF WORK FREE OF TRASH AND DEBRIS ON A DAILY BASIS, PROVIDE FOR ON-SITE RESTROOM FACILITIES AND FF FINISHED FLOOR SF SQUARE FOOT(FEET) VICINITY MAPFO FACE OF SS STAINLESS STEEL o MAKE ANY OTHER NECESSARY PROVISIONS TO PROTECT FINISHED ELEMENTS AND MAINTAIN A CLEAN, SECURE,AND WEATHER-MANAGED GA GAUGE SIM SIMILAR N WORK SITE. PROVIDE EROSION CONTROL AND DEBRIS MANAGEMENT AS NECESSARY PER LOCAL CODES. Gs GYPSUM BOARD To TOP OF co HM HOLLOW METAL TYP TYPICAL 16. CONTRACTOR TO PROVIDE ABATEMENT AND POLLUTION CONTROL AS NECESSARY FOR ALL REMOVED MATERIALS. HT HEIGHT UON UNLESS OTHERWISE NOTED A0 . 0'0 17. COORDINATE AND PROVIDE COMPLIANT MODIFICATIONS TO EXISTING FIRE ALARM AND/OR FIRE SPRINKLER SYSTEMS AS REQUIRED. VIF VERIFY IN FIELD BUILDING CODE ANALYSIS ;B „ ( L T OSSC STRUCTURAL SPECIALTY CODE(OSSC)2014 /"--- %.„. i 1 r—T---- CONSTRUCTION TYPE: IIIB,SPRINKLERED ARCHITECTURE, LLC I (E)OCCUPANCY GROUPS: M(B2) 2808 NE MLK,ste G / BUILDING HEIGHT: 1-STORY PORTLAND, OR 97212 E Cl. ) (E)BUILDING AREA: 13,583 SF+/-(B), / ( ALLOWABLE BLDG.AREA: 19,000 SF(PER TABLE 503) 503.454.6793 ( C2 )C C3 4-C6) inkbuiltdesign.com AREA OF WORK: 1,530 SF(B2) / C 11535' S,ti, Cir f II TABLE 508.3 NON SEPARATED OCCUPANCIES I .�' I I a l f G I I I I NO SEPARATION REQUIRED. c,..*** �. � 1008.1.9.3 EXCEPTION 2: .;11:11:1:4611: ` (E)ADAPARKING �� • '# WHERE LOCKS AND LATCHES ARE PROVIDED AT MAIN EXTERIOR DOORS, ".' INT SPACES TO REMAIN, , "" 5/ '` TYp, PROVIDE SIGNAGE STATING"THIS DOOR TO REMAIN UNLOCKED WHENIr 69 BUILDING IS OCCUPIED" At OF 00 1A� 1014.3 COMMON PATH OF TRAVEL REQUIRED:MAX 75' ..,. 4 TABLE 1015.1 62 / 610 �, ) / —II IAll NUMBER OF EXITS REQUIRED: TBD / NUMBER OF EXITS o XI S PROVIDED: 1 CNI (B6-B7) „r off 1 TABLE 1016.2 EXIT ACCESS TRAVEL DISTANCE:MAX 200 �,° Ol ` ." TABLE 1018.2 MINIMUM CORRIDOR WIDTH=44",>50 OCC. S ) • �.�..I 4/... / ( 64 ) / r'i06 ♦ .00. 1015.2.1 EXP.2 TWO EXITS SEPARATION QR' / ( B3 ) a �I�; D2 ) ., E 11515 �: IN BUILDINGS EQUIPPED WITH AUTOMATIC SPRINKLERS-EXITS SHALL NOT= �/ # BE LESS THAN 1/3 THE LENGTH OF THE OVERALL DIAGONAL OF THE AREA CJ) O w �, B2 � p3 ) , .�. "�' s ` r *Noir SERVED. a i liftiit%L. (E4-E5) kt / D 11525 ( D5 ) a -77 / CHAPTER 29 PLUMBING (E)ADA BATHROOMS TO REMAIN. O 0 ( B1 ) � 111116 B 1 45 o - 8' 4 -` / CD w N 2 N D4 f -� +50CM . N i ill ,.., CC w f : ' . > C G •1 Q Alig F:' W CD C? (EN)" .... . i:7J * ... ....... ... < ,._ 400AftI/fl Aw r**.., / , e61110 .4.6 � DATE: 11/01/2019 MUM ilb 410110 MIN A 1155541-A3 / B2-D6 DEMO Q � REVISIONS iiiviiii A / AREAS OF WORK , ` Q NI („ DUR844,J , AP SITE PLAN AND CODE ANALYSIS 0 N ID ,r SITE PLAN — B2 D6 1 A1. 00 1" 60'-0" i PLUMBING FIXTURE CREDITS DEMO LEGEND DEMO PLAN NOTES : 3 .. ILT FIXTURE #EXISTING #REMOVED #NEW FIXTURES NET TOTAL CREDITS 1 I EXISTING CONSTRUCTION TO REMAIN A. REMOVE ALL CONSTRUCTION FIXTURES COMPLETE. REMOVE ALL UN-USED ARCHITECTURE, LLC WATER CLOSET 2. 0 0 12, o C _ _ _ 3 (E)CONSTRUCTION TO BE REMOVED CONDUIT, PIPING AND WIRING 2808 NE MLK,ste G LAVATORY Iti 2 2 2 0 COMPLETE COMPLETE. PORTLAND, OR 97212 HAND SINK m m 0 0 0 B. MAINTAIN EXISTING FIRE SPRINKLER 503.454.6793 KITCHEN SINK $ c 0 0 rSYSTEM,TO BE PERMITTED AND inkbuiltdesign.com SHOWER m 1 0 0 1 MODIFIED UNDER SEPARATE PERMIT. WATER HEATER $ 0 ) 1 0 C. EXISTING ELECTRICAL SYSTEM TO Q ED AJ?e REMAIN. S'� *f D. ALL EXISTING SUPPLY AND RETURN C5`, �- AD ate' DUCTWORK TO REMAIN. 4.7 f T/11* ' C �.' . 3 ,i- L g� (E)CEILING,LIGHTING O Q . AND MECH.TO REMAIN. 'I (E)SUSP.CLNG.TO REMAIN. N i� i -IMi�X�li / FT �1 W VACANT ' I I 1 — -IL I I v, 62 ) BLDG ELEC I I I II Ir u ' W I (--- I 1 III 7L JI I ' C� o~c � i I I III �� — i - - - _ I F TI- - - n g_ i DEMO(E)SINK,SALVAGE - «.b. ,A� ,.aFv, I 1- —1 II I— ��� II IL= FOR RE-USE 7 V � flI II _ a Q \\ _ II I �� IIII 1 II -11 Q I— ce �` LJ _ _ 40. I v VACANT IC— '� ����� I I `� N REMOVE(E)SINKS, ( D6 ) �1� JJ = 2 Q I, CAP PLUMBING III •1 ba1. INSIDE WALL w PATCH AND i —•� �/ 1.1k �- — — — p 4111 REPAIR WALL REMOVE(E)CABINET AND r_---7- — _ o•�� — T� CD _ , _ �� SINK II {� I� �'� II i ��(�� I in Ce it Tfl REMOVE(E)WATER HEATER ..,.., ,. . __ _.� I I I . _ z E_ RELOCATED(E)ELEC.PANEL (E)BATHRO' �AND 1 _ TO OTHER SIDE OF WALL. BREAK :.OM TO DATE: 11/01/2019 rV RE4.� N. I f - - r i1 i B2-D6 DEMO _. . 11 I REVISIONS III - il L ADJACENT TENANT I- , Q �' ¢I I DR. RICHARD 11 N ai I WIPPLE DDS I EXISTING AND o I ( Dl ) DEMO PLANS N 0 SUITE B2 - EXISTING AND DEMO PLAN SUITE D6 - EXISTING AND DEMO PLAN A2. Z0 NEW WORK LEGEND FLOOR PLAN NOTES LT I A. SEE A5.00 A5.01 FOR TYPICAL ADA v I EXISTING CONSTRUCTION TO REMAIN ARCHITECTURE, LLC REQUIREMENTS,CLEARANCES, PROVIDE MTL.STUD WALL TO MATCH(E) MOUNTING HEIGHTS AND A4.00 FOR 2808 NE MLK, ste G TY( P. WALL DETAILS. PORTLAND, OR 97212 B. ALL DAMAGED,ALTERED,OR REWORKED 503.454.6793 AREAS SHALL BE PATCHED AS REQUIRED inkbuiltdesign.com AND FINISHED TO MATCH EXISTING CONDITIONS OR AS SPECIFIED TO ��' ,D A/ PROVIDE A"LIKE NEW" FINISH. ���'C r�� ill C. INSULATION PROVIDE SOUND BATTS AT SAD. ii ALL NEW INTERIOR WALLS AND W , I' '' rr, C CEILINGS. D. DOOR HARDWARE-ALL NEW HARDWARE 'e ./P, f'..4 `s Rt TO BE LEVER TYPE, FULLY ACCESSIBLE. (J S, 0 E. ALL NEW WALLS MATCH HEIGHT OF ' r OF 0��C� EXISTING WALLS. F. PATCH/REPAIR AND PAINT ALL NEW AND EXISTING WALLS-COLOR AS SELECTED BY OWNER. G. ; : WALL BRACING WALL TYPES SUSPENDED CEILING . 3 _ 1 L T ARCHITECTURE, LLC TWO FIXTURE HANGING AT LATERAL WALL OPPOSITE CORNERS SECURED 2808 NE MLK, ste G BRACE ABOVE TO STRUCTURE CEILING.ALTERNATE PORTLAND, OR 97212 DIRECTIONS TO '11111V TWO(2)MAIN 503.454.6793 STRUCTURE,SEE 1111 PARTITION WALL \\ SEE PARTITION WALL BRACING DETAIL RUNNER LIGHT BRACING DETAIL CLIPS AT OPPOSITE inkbuiltdesign.com `4% CORNERS \ '�tD ASC eik \kir 4�� '�;'�� UNDERSIDE OF STRUCTURE , POST AT 121FFET �� _`� LATERAL WALL BRACING 4 FEET O.C. O.C.EACH WAY Gj i' ALTERNATE DIRECTIONS , ACOUSTIC BATT INSULATION TO 4'ON • /� ,A D EACH SIDE OF PARTITION WALL AT � , ✓ '/ �� OFFICES AND RESTROOMS �� // .� SUSPENDED CEILING SYSTEM i�♦ 41 �� NEOPRENE FOAM TAPE CONT.BETWEEN BLOCKS L.,. a S , CASING BEAD \ :I poi FASTEN RUNNER TO CEILING SUPPORT AT 2 /Y� r OF ORvt -.) FEET O.C.THRU NEOPRENE BLOCKS ANGER W IRE AT 45 DEG. ACOUSTIC BATTS AT OFFICE AND BATHROOM WALLS FOUR WAYS MAIN r� 5/8"GYPSUM BOARD I RUNNER ' �,�� I:11. METAL STUDS,SEE SCHEDULE FOR GUAGE, SAFETY WIRE ATTACHED TO CEILING SPACING AND HEIGHT GRID FIXTURE HOUSING,WRAPPED AROUND FIXTURE HANGING WIRE MIN. PARTITIONS FOUR TIMES.SECURE AT DIAGONAL CORNERS NOT CONTAINING MAIN N LATERAL WALL BRACING IN LIEU ACOUSTIC SEALANT AT SLAB RUNNER LIGHT CLIPS CROSS M OF BRACING ABOVE CEILING NOTE: RUNNER ■ ■ ■ PROVIDE ADJACENT WALL 0,1450 POWDER ACTUATED DRIVE PIN WITH REQUIREMENTS ARE FOR LIGHT FIXTURES WEIGHING 56 LBS.OR LESS.LIGHT FIXTURES FRAMING FOR LATERAL SUPPORT 1/4 INCH EMBEDMENT AT 4'O.C.MAX INTO WEIGHING MORE THAN 56 LBS.TO BE INDEPENDENTLY SUPPORTED FROM STRUCTURE. LU WALL LATERAL BRACING ON WALL PARTITION WALL TO GRID CEILING RECESS RECESS MOUNTED FIXTURE SUPPORT 1""."" Li) W cc IBC METAL STUD TABLE-MAX WALL HEIGHT LU I Ci- MAX WALL HEIGHT 0 Q STUD GUAGE STUD SPACING SIZE DESIGNATION COMPOSITE NON-COMPOSITE Le SECTION SECTION O 3 Z w ,r 3 5/8" 25 362 S 125-18 16" 16'-2" 12'-2" O W N 24" 13'-2" 9'-11" / 20 362 S 125-30 16" 20'-8" 23'-3" ST)UROOF 4X4 BLOCK W/A35 CLIPS W(4)#6 X 1/2"SPAR L�L G Q N 24" 18'-1" 18'-11" SCREWS AND(4)8d X 1-1/2"NAILS EACH SIDE CO 0 H I Ol 6" 25 600 S 125-18 16" 20'-1" -- ir BRACE TO MATCH WALL WIDTH W/33 MIL �„ W 24" 16'-4" -- m THICKNESS,MIN. > Q ct 20 600 S 125-30 16" 30'-8" 30'-1" 14 -O O Z Q 24" 25-0" 26,-3" tQ _I = v) o VALUES LISTED ARE BASED ON STEEL STUD MANUFACTURERS ASSOCIATION ��� -I tLn Ce (SSMA)TABLES FOR NON-STUCTURAL COMPOSITE SECTION IN INTERIOR I CLIP FLANGES AND BEND EACH ce Lt) Q APPLICATIONS(5 PSF)WITH DEFLECTION LIMIT OF U120. :•• END. Q 0 )#10 SCREWS1. VALUES FOR COMPOSITE SECTION REQUIRES 5/8"MIN.GYP.BD.ON BOTH � BRACE EQ.SPC DCH END OF = SIDES W/#6 TYPE S DRYWALL SCREWS AT 12"O.C.FOR STUDS AT 24"OC AND ' 16"OC FOR STUDS AT 16"OC. 4 WALL PER PLANS 2. HEIGHT LIMITS ARE LESS WHERE SHEATHING IS ON ONE SIDE.PROVIDE DATE: 11/01/2019 BLOCKING OR STRAPPING ON OPPOSITE SIDE(NON-COMPOSITE VALUES). B2-D6 DEMO NOTE:BRACE CONNECTION AT ROOF TO FRAMING SCHEDULE PARTITION WALL BRACING DIRECTLY ATTACHED TO PLYWD. REVISIONS 2 Po cr CEILING AND WALL N O DETAILS _ O, 0 N W 1- ,._ A4 . 0 0 • DOORS CLEARANCES NOTES PULL SIDE APPROACH PUSH SIDE APPROACH ACCESSIBLE ROUTE INDICATOR LINE :BUIL T \ \ REFERENCE CODE SUMMARY SHEETS FOR 24" THESE DIAGRAMS ARE BASED OF THE INFORMATION ARCHITECTURE, LLC / EXTENT OF ROUTE / CONTAINED IN ICC A117.1-2009 AND CHAPTER 11 OF THE z MAX 2808 NE MLK, ste G z_ / BUILDING CODE. THEY ARE REPRESENTATIVE OF THE PORTLAND, OR 97212 " � GENERAL REQUIREMENTS THAT APPLY TO THIS PROJECT. oo 32 X/ z/z1/// 503.454.6793 oo MIN / , z z _ - THEY ARE NOT REPRODUCTIONS OF THE INFORMATION Lo o 18" MIN ,/ _ '� `V ' `" — — in kbuiltdesign.com 0 24" m m ' CONTAINED IN THE ICC A117.1-2009. REFER TO THE ICC ci Li_ `24" PREFERRED /, �` =`' A& A117.1-2009 FOR ADDITIONAL INFORMATION. En A 32"jr oo � � J zoo � aao Zaz `C3 �C A / Q � � _ � o oho fvz C5 , IAD. MIN o / oco , o ¢ }- ¢ Ca §* L±) ZLU raj T ► , X C _ X=12' MIN WHEN DOOR z � -- v o v o o z < o - r FRONT APPROACH HAS CLOSER AND LATCH N a z i, N 0 Z n = Q Li v f . • a o (Pi (fi k" PULL SIDE PUSH SIDE 12" / MIN.* , TYPICAL ACCESSIBLE ROUTE OF OF 00 Q 60" o ir- ,;// -, \ 60" MIN a cc occ 1 I o X/ 22" 32"/ 1 2 I r� /MIN. Or MIN , / CV / 32" X a *IF DOOR HAS o W MIN o // BOTH LATCH ' / `° I ' X=36"MIN WHEN Y=60" o / AND CLOSER / m X=42"MIN WHEN Y=54" 'i i (n 0 LJ LJ HINGE APPROACH 0- 60"DIAMETER TURNING CIRCLE T SHAPED SPACE FOR 180 TURNS >. 0 ce PULL SIDE PUSH SIDE o- 0¢ ADDITIONAL INFORMATION O 1 - ce IJIIM FIGURE 304.3IN a A aao Q 32" 24" MIN aIII MIN /fl I 32" dr a \ - _—I C U C]- E // CHANGE IN LEVEL-SQUARE CHANGE IN LEVEL-SLOPED J3 MIN o Q1.11,..ul pl, Y=54"MIN IF DOOR HAS o / Y=48"MIN IF DOOR HAS CLOSER CLOSER LEVEL CHANGE ON FIGURE 303 LATCH APPROACH DATE: 11/01/2019 TREAD DOOR CLEARANCES AT SWING FIGURE 404.2.3.2 DEPTH MIN ;MIN B2-D6 DEMO C H ,_ REVISIONS J X 32" MIN jr - _ r-, 13 a POCKET OR SLIDING DOOR m r.1 OLL ADA DETAILS o J =m o DOORS AND (TN / 32" X 32" MIN oN MIN / I CLEARANCES 00 SWING DOOR BIFOLD DOOR DOOR CLEARANCES AT DOORS FIGURE 404.2.2 STAIR HANDRAILS FIGURE 505.10.2 AND .3 A5 . 00 , = PLUMBING FIXTURES MOUNTING HEIGHTS 3 U I L T LAVATORY LAVATO NOTE:WALL MOUNTED DEVICES SHALL NOT EXTEND MORE THAN 4"BEYOND WALL SURFACE MIRROR 16 1/4" MIN y WHEN LOCATED BELOW 6'-8" ARCHITECTURE, LLC __ 2 36' MIN 3g' MIN z z Ea 2808 NE MLK,ste G O < // _z g O18" 18" 18" 18" • OR 97212 i- ft PIPE WRAP- _ - �- N [—I ` MIN MIN PORTLAND, "' TYP N / / ` ` - --- _f a I e 503.454.6793 o /% r /%I/,� f • • inkbuiltdesi n.com .st �� m 19" MAX OAK ���� MAX HEIGHT TO ALLgKNEE CLEARANCE �� I48" z z d, = ko 00 0 QED AR g u d- OPERABLE PARTS o AREA 1 LAVATORY CLEARANCE •-• e• N Stm 2EC'`�� �+ CAU�4 LAVATORY KNEE 48" MINI i Q ♦a. w /T r ,I;.4 C ROBE TOWEL HAND SEAT PAPER TOWER SANITARY 0. CLEARANCE AND 8" MIN 6" MAX TO CLEARANCE i� \ 1 MIRROR MOUNTING ® HOOK BAR TOWEL COVER DISPENSER NAPKIN •I v,!, l;►; e I 17" MIN DEPTH • j 48" MIN jr BAR DISPENSER DISPENSER J,°t. °i s'�+ CLEARANCE AT LAVATORY FIGURE 606 APPROACH 1 2 �+� TRANSFER SEAT 36" R.O. 15" MAX. 18" 42" CEILING J �� 3" MAX OF/ QR 14" BACK 1 PROJECTION MIN �� =- up g. Fill A Vs m c') �, ��� °r° - z uz MAMIN24 l _ O ' Li_i�L OQce co ., ¢ itkZn a o, W Oin 48" Co ♦ °° N `° 1O V1 v rn W A APPROACH ul n w O CX 1- 3 (i) CD tr 3'X 3'SHOWER BLOCKING FOR GRAB BARS it, 60" MIN w AT SHOWER LOCATIONS s FEC \ HORN/ STROBES THERMOSTAT/ ROOM\ ` \ O p URINAL MOUNTING HEIGHT CLEARANCES AT SHOWERS FIGURES 608 CLEARANCE AT WATER CLOSETS FIGURE 604.3 STROBE SECURITY/ SIGNAGE d O¢ 6" MAX FIRE ALARM C) H ce FOUNTAIN 36" MIN AREA OF BLOCKING WALL MOUNTED DEVICES AND APPLIANCES w 2 (N AT FRAMED WALL 58" TYP 17"- 19" 30" 1, DEPTH 30 2 Q N 12" MIN 52 TYP z NOTES I- = al F > 0 a il %ra'z= ii '� Mo ���� z THESE DIAGRAMS ARE BASED OF THE INFORMATION CONTAINED IN THE ICC O Z 2f O r- LL z Or- �� o I A117.1-2009 AND CHAPTER 11 OF THE BUILDING CODE. THEY ARE REPRESENTATIVE —I C I N r� g p C�=—i'��= °I ° OF THE GENERAL REQUIREMENTS THAT APPLY TO THIS PROJECT. THEY ARE NOT da„ cc Ln Q °- ~�, / / REPRODUCTIONS OF THE INFORMATION CONTAINED IN THE ICC A117.1-2009. REFER Ln Q _� z "� / TO THE ICC A117.1-2009 FOR ADDITIONAL INFORMATION. _ T- I� m M min ErN FREE-STANDING FIXTURE BUILT-INFIXTURE DATE: 11/01/2019 18" TP 3'-3" X / EQUIPMENT 48" MIN i B2-D6 DEMO GRAB BARS AT WATER CLOSETS FIGURES 604 17"- 1 g"� O PERMITTED IN SHADED AREA REVISIONS 0 ON 1,/ :z LIJ g � O8ao - • _ O d' - cn I //I N � _ o - 4 o m` �� II 17" 19" ADA DETAILS - • r • `t `' "' `t�U z --8" MIN 24" MAX PLUMBNG FIXT. AND Z' OUTLET SWITCH OUTLET ABOVE FIRE ALARM PULL z 4 4' MOUNTING HTS. NFIXTURE IN ALCOVE 00 COUNTER STATION N 6" MAX TOILET ROOM ACCESSORY MOUNTING HEIGHTS WATER COOLERS AND DRINKING FOUNTAINS FIGURE 602 n 5 . 0 1