Loading...
Report I5'720 SW /924f-i &2O'arl /75r2o/9-0o395 . . ,,,,• .,„.,, SLA _An 31 0 Wp :. ; s 1 ;•;...._ ,1 _.,::.,--...;.-;-..4, SOLAR - t„ " �,. 2Jz - C BANKABLE EFFICIENCY ' NAUM TEU w ✓' d'' ✓E iY / n INDUSTRY LEADING WARRANTY `�-- - k All our products include an industry leading 25-year product workmanship g '`"/// g.Iny f.'/> /%,�,b,y,,4/ and 30 year performance warranty. '.' " , " 35+ YEARS OF SOLAR INNOVATION ,... , Leveraging over 35+years of worldwide ":% experience in the solar industry, Silfab „''" , ' e;/ , is dedicated to superior manufacturing s" "' processes and innovations such as " Bifacial and Back Contact technologies, p to ensure our partners have the latest in solar innovation. , NORTH AMERICAN QUALITY s Silfab is the largest and most automated '...5....-...; solar manufacturer in North America. Utilizing premium quality materials and Y+l' strict quality control management to deliver ' .:y the highest efficiency, premium quality PV r modules 100% made in North America. —� / iF s r , a , BAA/ARRA COMPLIANT DOMESTIC PRODUCTION Silfab panels are designed and manufactured to meet Buy Silfab is 100%North American which means our customer American Act Compliance.The US State Department,US service is direct,efficient and local.Your solar panels can be Military and FAA have all entrusted Silfab panels in their delivered anywhere in the Continental USA within days. solar installations. AESTHETICALLY PLEASING LIGHT AND DURABLE All black sleek design doesn't compromise on quality. Engineered to accommodate low load bearing structures up to 5400Pa.The light-weight frame is exclusively designed for PID RESISTANT wide-ranging racking compatibility and durability. PID Resistant due to advanced cell technology and material selection. In accordance to IEC 62804-1 LOWEST DEFECT RATE Total automation ensures strict quality controls during the entire manufacturing process at our ISO certified facilities. 48.18 ppm as per December 2018. .' r a':'SJ. t ja s+ .. 4a m✓ 1r } . 4 % z r ." a s, s's .,, t"+ ,:•.'':':',:',::::',.' i i eY .„ ¢q���5 �,;.,:,...y'::', '' ' '+, r> T ;•\•s:'f. M7 ''c*. :.i, F: 'r ,'.',''''',•;:,'",)::1.", . , ' Y Electrical Specifications SILFAB SLA Monocrystalline Test Conditions STC NOCT Module Power(Pmax) _._ 310 234 Maximum power voltage(Vpmax) V 33.05 29.7 Maximum power current(Ipmax) A 9.38 7.88 Open circuit voltage(Voc) V 40.25 37.2 Short circuit current(Isc) A 9.93 8.14 Module efficiency % 19.0 17.9 Maximum system voltage(VDC) V 1000 Series fuse rating A 20 _ Power Tolerance WR -0/+5 Measurement conditions:STC 1000 W/m2•AM 1.5•Temperature 25°C•NOCT 800 W/m2•AM 1.5•Measurement uncertainty s 3% •Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by±5%and power by-0/+5W. Temperature Ratings SILFAB SLA Monocrystalline Temperature Coefficient Isc %/K 0.03 Temperature Coefficient Voc %/K -0.30 Temperature Coefficient Pmax %/K -0.3£1 NOCT(±2°C) °C 45 .-__. . . Oseratin:temperature °C -40/+85 Mechanical Properties and Corn sonentsLAB .-.. Module weight(±1 kg) k: 19 Dimensions(H x L x D;±1mm) mm 1650 x 990 x 38 Maximum surface load(wind/snow)* N/m2 4000 Pa upward/5400 Pa downward Hail impact resistance 0 25 mm at 83 km/h Cells 60-Si monocrystalline-4 or 5 busbar-156.75 x 156.75 mm Glass 3.2 mm high transmittance,tempered,antireflective coating _____ Backsheet Multilayer polyester-based Frame Anodized Al(Black) Bypass diodes 3 diodes-45V/12A,IP67/IP68 Cables and connectors(See installation manual) 1200 mm 0 5.7 mm(4 mm2),MC4 comIatible Module product workmanship.warranty _ 25 years** 30 years >_97%end of 15t year Linear power performance guarantee >_90%end of 121h year >_82%end of 251h year >_80%end of 30th ear o Certifications SILFAB SLA Monocrystalline ULC ORD C1703,UL 1703,IEC 61215,IEC 61730-1 and IEC 61730-2 Certified. FSEC and CEC listed.IEC 62716 Ammonia Corrosion,IEC 61701:2011 s Product Salt Mist Corrosion Certified UL Fire Rating:Type 2(Type 1 on request) Factory 1509001:2015 E *Please refer to the Safety and Installation Manual for mounting specifications. 38 **12 year extendable to 25 years subject to registration and conditions outlined under Drainagela8)/- -"— , F, 'Warranty"at www.silfabsolar.com. Grounding ' I A Warning:Read the installation and User Manual before handling,installing and operating e ®w Hole e E modules. 1 8 g •.1 Third-party generated pan files from 2819 TOP PERFORMER gib Modules Per Pallet:26 ' J( Fraunhofer-Institute for Solar Energy rD ] ecE PalletsMontng Salot Systems ISE are available for download .:e Modulec936 JLE BS at:www.silfabsolar.com/downloads RELIABILITY SCORECARD 3 �o c-c - Profile View CI - Icmi'..m ^— z Silfab Solar Inc. rii 240 Courtneypark Drive East Mississauga ON L5T2Y3 Canada 04.21,21 s S`I f a b "*" Tel+1 905-255-2501 I Fax+1 905-696-0267 Grounding SLB D mens.onsn mm i3 Hole tolerances xlmm Socue info@silfabsolar.com I www.silfabsolar.com "°"'°""""'�2mm D' "°`"°"°""` e In © ® Silfab Solar Inc. 958 800 Cornwall Ave 990 g Bellingham WA 98225 USA Tel+1 360-569-4733 . Data'Sheet Enphase Microinverters Region:AMERICAS Enphase Micros Designed for AC Module (ACM) applications,the smart grid-ready M is for AC Module built on the latest technology from Enphase.The high performance IQ Microinverters increase energy harvest Applications from PV modules while lowering system cost for installers. Part of the Enphase IQ System,the IQ 7+ACM microinverters are compatible with the Enphase IQ Envoy and Enphase Enlighten monitoring and analysis software. Enphase Microinverters set the highest benchmark in quality and reliability in the PV industry. Easy to install • Microinverter pre-mounted on PV modules for easy transport • and install • Fast installation with Enphase Q Cable • Built-in rapid shutdown compliant(NEC 2014&2017) Versatile and Reliable . . • Available through multiple module suppliers IQ 7+ACM .. 9 P PP ==! • Optimized for high powered 60-cell and 72-cell modules s®ar • Adaptable for residential and commercial installations • Works with railless or traditional racking systems • Class II double-insulated enclosure • _ • UL listed Smart Grid Ready • Complies with fixed power factor,voltage and frequency ride- through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) 4111), CERTIFIED fE3WO 65 E5e1 EN PHAS E. To learn more about Enphase offerings,visit enphase.com V • Enphase IQ 7+ Microinverter for AC Module Application INPUT DATA(DC) IQ7PLUS-72-ACM-US Commonly used module pairings' 235 W-440 W+ Module compatibility 60-cell and 72-cell PV modules Maximum input DC voltage 60 V Peak power tracking voltage 27 V-45 V Operating range 16 V-60 V Min/Max start voltage 22 V/60 V Max DC short circuit current(module Isc) 15 A Overvoltage class DC port II DC port backfeed under single fault 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required, AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) Peak output power 295 VA Maxhrnum continuous output power 290 VA Nominal(L-L)voltage/range' 240 V/211-264 V 208 V/183-229 V Maxirnurr continuous output coo cot 240 V:1.21 A 208 V:1.39 A Nominal frequency 60 Hz Extended frequency range 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms Mak mum units per 20 A(L-L)branch circuit' 240 V:13 208 V:11 Overvoltage class AC port III AC port backfeed current 0 A Power factor setting 1.0 Power factor(adjustable) 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V Peak CEC efficiency 97.5% 97.3% CEO weighted efficiency 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connector type Integrated Enphase DC Connector Dimensions(WxHxD) 212 rim x 175 mm x 30.2 mm(without bracket) Weight .92 kg(2.03 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure.rating NEMA Type 6/outdoor FEATURES Communication Power line Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when Installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at enphase.com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverteis per branch in your area. To learn more about Enphase offerings,visit enphase.com ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. ENP HAS E. 2018-06-04 �� t, IRON RIDGE Class A Fire Rating Background All roofing products are tested andfr classified for their ability to resist fire. Test Setup Recently, these fire resistance standards Solar Modules Solar modules are given a Type were expanded to include solar equipment classification based on their as part of the roof system. Specifically, this materials and construction. requires the modules, mounting hardware Mounting System .. . and roof covering to be tested together as Mounting is tested as part of a ' system that includes type-tested a system to ensure they achieve the same modules and fire-rated roof covering. fire rating as the original roof covering. Roof Covering Roof covering products are given a These new requirements are being adopted Fire Class Rating of A, B or C based on their tested fire resistance. throughout the country in 2016. Burning Brand Test IronRidge Certification �x IronRidge was the first company to receive a Class A Fire Rating—the highest possible rating—from Intertek Group plc., a Nationally Recognized Testing Laboratory. A burning wooden block is placed on module as a fan blows at 12 mph. IronRidge Flush Mount and Tilt Mount Flame cannot be seen on underside of roof within 90 minutes. Systems were tested on sloped and flat roofs in accordance with the new UL 1703 Spread of Flame Test & UL 2703 test standards. The testing evaluated the system's ability to resist flame spread, burning material and *if structural damage to the roof. :. '7 Refer to the table below to determine the requirements for achieving a Class A Fire Rating on your next project. Flame at southern edge of roof is aimed up the roof as a fan blows at 12 mph.The flame cannot spread 6 feet or more in 10 minutes. .✓ :.H '" ' 1 N` ., x 91 % 3 Atb{ ;. Flush Mount Any Slope Type 1, 2, & 3 Class A Tilt Mount s 6 Degrees Type 1, 2, & 3 Class A 'Class A rated PV systems can be installed on Class A B and C roofs. Frequently Asked Questions What is a "module type"? What attachments and flashings are deemed compatible with Class A? The new UL1703 standard introduces the concept of a PV module type, based on 4 construction parameters Attachments and their respective flashings are not and 2 fire performance parameters.The purpose of constituents of the rating at this time.All code-compliant this classification is to certify mounting systems without flashing methods are acceptable from a fire rating needing to test it with every module. standpoint. What roofing materials are covered? What mounting height is acceptable? All fire rated roofing materials are covered within this UL fire testing was performed with a gap of 5", which is certification including composition shingle, clay and considered worst case in the standard. Therefore, the cement tile, metal, and membrane roofs. rating is applicable to any module to roof gap. What if I have a Class C roof, but the jurisdiction Am I required to install skirting to meet the fire now requires Class A or B? code? Generally, older roofs will typically be"grandfathered No, IronRidge achieved a Class A fire rating without any in", and will not require re-roofing. However, if 50%or additional racking components. more of the roofing material is replaced for the solar installation the code requirement will be enforced. What determines Fire Classification? Where is the new fire rating requirement code listed? Fire Classification refers to a fire-resistance rating system for roof covering materials based on their ability 2012 IBC: 1509.7.2 Fire classification. Rooftop to withstand fire exposure. mounted photovoltaic systems shall have the same fire classification as the roof assembly required by Section Class A- effective against severe fire exposure 1505. Class B-effective against moderate fire exposure Class C- effective against light fire exposure Where is a Class A Fire Rating required? What if the roof covering is not Class A rated? The general requirement for roofing systems in the IBC refers to a Class C fire rating. Class A or B is required for The IronRidge Class A rating will not diminish the fire areas such as Wildland Urban Interface areas (WUI) and rating of the roof, whether Class A, B, or C. for very high fire severity areas. Many of these areas are found throughout the western United States. California What tilts is the tilt mount system fire rated for? has the most Class A and B roof fire rating requirements, due to wild fire concerns. The tilt mount system is rated for 1 degrees and up and any roof to module gap, or mounting height. Are standard mid clamps covered? Mid clamps and end clamps are considered part of the PV"system", and are covered in the certification. . __ More Resources _ Installation Manuals Engineering Certification Letters t � Visit our website for manuals that include UL We offer complete engineering resources y , , 2703 Listing and Fire Rating Classification. 4, and pre-stamped certification letters. ? 1110101Z4 IRONRIDGE FlashFoot2 The Strongest Attachment in Solar IronRidge FlashFoot2 raises the bar in solar roof R protection. The unique water seal design is both elevated and encapsulated, delivering redundant layers of protection against water intrusion. In addition, the twist-on Cap perfectly aligns the rail attachment with the lag bolt to maximize mechanical strength. ,:., y 3h Twist-On Cap �r FlashFoot2's unique Cap design encapsulates the lag bolt and locks into place with a simple �. Three-Tier Water Seal twist.The Cap helps FlashFoot2 deliver 1. FlashFoot2's seal architecture utilizes three superior structural strength,by aligning layers of protection.An elevated platform the rail and lag bolt in a concentric diverts water away,while a stack of rugged load path. components raises the seal an entire inch. The seal is then fully-encapuslated by the Cap. FlashFoot2 is the first solar attachment to pass the TAS-100 Wind-Driven Rain Test. '444 4 A f ' Single Socket Size A custom-design lag bolt allows you to install FlashFoot2 with the same 7/16"socket size used on other Flush Mount System components. Lag Bolt 5/16"x 4.75" Water-Shedding Design (3"penetration into rafters) An elevated platform diverts water away from the water seal. F ;; Tech ode Installation Features B . A Alignment Markers Quickly align the flashing with chalk lines to find pilot holes. B ` Rounded Corners Makes it easier to handle and insert under the roof shingles. C Reinforcement Ribs •A Help to stiffen the flashing and prevent any bending or crinkling during installation. Benefits of Concentric Loading 1200 FlashFoot2 1000 Traditional solar attachments have a horizontal offset between the rail and lag800 FlashFoot Leading Competitor bolt, which introduces leverage on the lag Q 600 bolt and decreases uplift capacity. 400 9 Low-Cost Competitor FlashFoot2 is the only product to align the 200 rail and lag bolt. This concentric loading design results in a stronger attachment for 0 1 2 3 the system. Rail-to-Lag Offset(in) Testing & Certification Structural Certification Designed and Certified for Compliance with the International Building Code &ASCE/SEI-7. Water Seal Ratings Water Sealing Tested to UL 441 Section 27 "Rain Test" and TAS 100-95 "Wind Driven Rain Test" by Intertek. Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. UL 2703 Conforms to UL 2703 Mechanical and Bonding Requirements. See Flush Mount Install Manual for full ratings. n , r. IRONRIDGE XR Rail Family Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, . x but the worst storms in 40 years. High winds capable of 7r ,' f 4. ripping panels from a roof, and snowfalls weighing ' ,,'" x� enough to buckle a panel frame. /'r • / ", f XR Rails are the structural backbone preventing - ,c l ,1. � + these results. They resist uplift, protect ,f .1i K against buckling and safely and efficiently ;` 't transfer loads into the building structure. �?- f Their superior spanning capability '` � --`" �- - -t I. requires fewer roof attachments, " ' reducing the number of roof 7.-z. penetrations and the amount 1. . of installation time. ;,"F � , r �A .., c4,ix , .,,, ,-= ; 4, Force-Stabilizing Curve �` _ hs ` Sloped roofs generate both vertical and lateral • forces on mounting rails which can cause them , 4 > ry to bend and twist.The curved shape of XR Rails t - , p4:4"-?,4--I-4'..:.:.;�, £•r, • ,44„ s is specially designed to increase strength in both 5¢y ; ' 4 ;,, , directions while resisting the twisting.This unique 4 �,,` -i 44 ; Fr' feature ensures greater security during extreme s Y ¢ Jr weather and a longer system lifetime. a Compatible with Flat& Pitched Roofs Corrosion-Resistant Materials XR Rails are :,,,-4,44, -;(0,.',4 ',...; IronRidge offers XR Rails are made of marine grade ;4compatible with a range of tilt leg g: aluminum alloy,then protected with an FlashFoot and options for flat i anodized finish.Anodizing prevents surface other pitched roof • roof mounting ' and structural corrosion,while also providing attachments. applications. a more attractive appearance. le A�`�`t k . ;,, �.r r y 1 F �, "' t�� ^";�} � ����, ��:'' a ,� ;,xy:. �:�",�i'� ''e �4,#"` rk+�;;w" �• " z" • + �`' ;4'•: ,&.a 'Q AC` '. .t _ :a e!si4O;4'..';a`+fir., 7 a lf'g.�"� yn. "4 _:,x;i/ `� ^;�,; s • s� ' €;,..,: � xs '�.'�z^-£".t, a,�� *'',::.. lr�. ..r.�'"� �p� �.�;�t�d.E gip' s y..;� 'B mf��* o-�*; re. .. ..14':‘,.''''''''4',. F 6,.. "�;V'W -- f' . . .. �t ", XR Rail Family ' • The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. --,,„--mr,--,..- -'''': -.. .. i lib --...,.................4.16111 -......................malk XR10 XR100 XR1000 XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among rail,perfectly matched to regions mounting rail. It supports a range of solar mounting rails. It's built to handle without snow. It achieves 6 foot spans, wind and snow conditions,while also extreme climates and spans 12 feet or while also staying light and economical. maximizing spans. more for commercial applications. • 6'spanning capability • 8'spanning capability • 12'spanning capability • Moderate load capability • Heavy load capability • Extreme load capability • Clear anodized finish • Clear&black anodized finish • Clear anodized finish • Internal splices available • Internal splices available • Internal splices available Rail Selection The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria:ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. ,5�•a`� .-. ln`F��: 'xx.' . �'�. � :a:, `�.. .s..:a.�` :G ,� $�%z . : � �;µ s, ,M1�.t3 +::,"....., �#. �. `S� • 100 120 1 *� -7 None ,:: *u , ����� 140 XR10 XR100 • '.41 .;-r.if:-.,=,4.4 160 100 10-20 H.. • 120 • x „�a 140 � � � t i i...._...._._... ...._._.. x e 160 $ • • I- i __ _M..__ ._. _.._ _.____ -1 I 100 120 , 30-40 - '� 140 I 160 50-70 1 160 5 80-90 i 160 v r-z .xmr 11':40f t'`. - ,11:1 .-.:. tyj,e v04.:4. '' .� IIV: _ - .sx sRfi`t"ts�';Y" Kms.,..n. ^z', ` ¢ ni.'^ ' �" k4eit$ j; t. K6 . . , < ,,° ? n«.��. ' "�'� .. a ,,, «at.;v,.,,r "ia� .� hk.. 47-� .e a �,: rc. `& <. x3 `s .1-1 .. :1.4� . a4 3y< IRONRIDGE UFO Family of Components Simplified Grounding for Every Application The UFO family of components eliminates the need for separate grounding hardware by bonding solar modules directly to IronRidge XR Rails.All system types that feature the UFO family—Flush Mount, Tilt Mount and Ground Mount—are fully listed to the UL 2703 standard. UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system. This leads to safer and more reliable installations. gxxQ a{%� ,,,.. r Stopper Sleeve .3 The UniversalUFO Fasteningsecurelybondssolar Object (UFO)toXRd The Stopper Sleeve snaps modules Rails.It comes assembled and lubricated,an onto the UFO,converting it into a bonded end clamp. can fit a wide range of module heights. b j f ' ...% � yg, qty ..e' Y / - - ' ' - ' ''/ Y, ' r f:.. Bonded Splice F x max: Each Bonded Splice uses self-drilling screws to form e a secure connection. No '''.4.1,,,, ,v44.,„9,4."/14.P" x+ r11101..„, s bonding strap needed. fr.. xf `. .` ti. 'rr'r ::''''''• '''' ' .. z 00000 a r 3 '' Grounding Lug A single Grounding Lug Bonded Attachments I connects an entire row The bonding bolt attaches .__._ ; of PV modules to the and bonds the L-foot to the grounding conductor. rail. It is installed with the same socket as the rest of the system. :. G Ye.4 -.":,.. y. <, , xr.. ., : x.;a :e�F� ,! (:: h fi. fY IRONRIDGE Flush Mount System : I,„„ , „„,..„ „,..„..,..„.„,,, „ i , „, .. ,. .. . ,..,„..„,„ f` Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Testedt PE Certified All components evaluated for superior Pre-stampedengineering en rneerin letters structural performance. .;; available in most states. Class A Fire Rating '. ..„, , Design Assistant Certified to maintain the fire resistance c Online software makes it simple to rating of the existing roof. ;,>, create, share, and price projects. UL 2703 Listed System Warranty Entire system and components meet . ` Twice the protection offered by °° newest effective UL 2703 standard. ,., competitors. System Diagram 0- - - 1 - - -0 0 • = -0 0- - - - - -0 0 4= gre 0 0_ : : _ _ _0 0 • 0 _ _ _ _ _ =0 0 iip — OUFO C., Stopper Sleeve • Grounding Lug Bonded Splice Ground Wire 4 Approved Enphase microinverters can provide equipment grounding of IronRidge systems, eliminating the need for grounding lugs and field installed equipment ground conductors (EGC).A minimum of two microinverters mounted to the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. UL Certification s , r.‘ � The IronRidge Flush Mount, , ' ,..;;;,::,.:4,• ;:,.. � Tilt Mount, and Ground Mount XR Rails v XR1000 Only Systems have been listed to ULr 2703 by Intertek Group plc. UFO/Stopper V V V _ t Bonded Splice V V N/A UL 2703 is the standard for evaluating solar mounting Grounding Lugs 1 per Row j 1 per Row 1 per Array systems. It ensures these devices Microinverters Enphase - M250-72, M250-60, M215-60, C250-72 will maintain strong electrical and & Power Darfon - MIG240, MIG300, G320, G640 mechanical connections over Optimizers SolarEdge- P300, P320, P400, P405, P600, P700, P730 an extended period of time in extreme outdoor environments. Fire Rating Class A Class A N/A Modules Tested or Evaluated with over 400 Framed Modules vrt n"_ ,,r _•ii t ` Refer to installation manuals for a detailed list. 4 XR Rails—,?;- - _ ., _. ._ . _____ ..... ... . ,. .._„...,.... ..____a_ XR10 Rail XR100 Rail XR1000 Rail Bonded _ ......ill_ A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability • 8'spanning capability • 12'spanning capability • Self-drilling screws • Moderate load capability • Heavy load capability • Extreme load capability • Varying versions for rails • Clear& black anod. finish • Clear& black anod. finish • Clear anodized finish • Forms secure bonding _w.,.,._ , x . -'_.x. . _,._ _,�.,r _._ . _.�_,�___ ..__..__. ...�, _ . UFOs Stopper Sleeves Grounding Lugs Microinverter Kits 1 1 L , , ., .. 174,004) ... - w -- Universal Fastening Objects Snap onto the UFO to turn Connect arrays to Mount MIs or POs to XR bond modules to rails. into a bonded end clamp. equipment ground. Rails. • Fully assembled & lubed • Bonds modules to rails • Low profile • Bonds devices to rails • Single, universal size • 6 different sizes • Single tool installation • Kit comes assembled • Clear& black finish • Clear& black anod. finish • Mounts in any direction • Listed to UL 2703 ---- - Attachments FlashFoot2 Slotted L-Feet Bonding Hardware Flush Standoffs li — Flash and mount XR Rails Drop-in design for rapid rail Bond and attach XR Rails Raise Flush Mount System with superior waterproofing. attachment. to certified attachments. to various heights. • Twist-on Cap eases install • Secure rail connections • T& Square Bolt options • Works with vent flashing • Wind-driven rain tested • Slot for vertical adjusting • Nut uses 7/16"socket • 4" and 7" lengths • Mill & black finish • Clear& black anod. finish • Assembled & lubricated • Ships assembled - -- Resources --- - - . 4. Design Assistant NABCEP Certified Training Go from rough layout to fully ., , ` ,- Earn free continuing education credits, :, engineered system. For free. `f ' while learning more about our systems. ... t..3 . ,, ,: t . , ,,,, ., ,,.,v••design ' �.;, s .:; ,. ,,. „ ., .xf- .. ., ,f 7, x^' ,;a'w'•'',': ,..d,.n,..-. ....:5,..., : .. a: ,. ..r. . a ,. Data Sheet Enphase Microinverters Region.AMERICAS Enphase IQ 7+ Micros Designed for AC Module(ACM)applications,the smart grid-ready Enphase IQ 7+ ACM Microinverter' is for AC Module built on the latest technology from Enphase.The high A liGatfans performance IQ Microinverters increase energy harvest pp from PV modules while lowering system cost for installers. Part of the Enphase IQ System,the IQ 7+ACM microinverters are compatible with the Enphase IQ Envoy1" and Enphase Enlighten'"" monitoring and analysis software. Enphase Microinverters set the highest benchmark in quality and reliability in the PV industry. Easy to install • Microinverter pre-mounted on PV modules for easy transport • and install • Fast installation with Enphase Q Cable • Built-in rapid shutdown compliant(NEC 2014&2017) Versatile and Reliable ENwsAsE. "' • Available through multiple module suppliers • Optimized for high powered 60-cell and ifiiittit 72-cell modules �z1 • Adaptable for residential and commercial installations • Works with railless or traditional racking systems • Class II double-insulated enclosure • UL listed :;rte Smart Grid Ready • Complies with fixed power factor,voltage and frequency ride- through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) CERTIFIED sevETI US a E341165 To learn more about Enphase offerings,visit enphase.com E PHASE Enphase IQ 7+ Microinverter for AC Module Application INPUT DATA(DC) IQ7PLUS-72-ACM-US Commonly used module pairings' 235 W-440 W Module compatibility 60-cell and 72-cell PV modules Maximum input DC voltage 60 V Peak power tracking voltage 27 V-45 V Operating range 16 V-60 V Min/Max start voltage 22 V/60 V Max DC short circuit current(module lsc) 15 A Overvoltage class DC port II DC port backfeed under single fault 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) Peak output power 295 VA Maximum continuous output power 290 VA Nominal(L-L)voltage/range' 240 V/211-264 V 208 V/183-229 V Maximum continuous output current 240 V:1.21 A 208 V:1.39 A Nominal frequency 60 Hz Extended frequency range 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms Maximum units per 20 A(L-L)branch circuit' 240 V:13 208 V:11 Overvoltage class AC port Ill AC port backfeed current 0 A Power factor setting 1.0 Power factor(adjustable) 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V Peak CEC efficiency 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connector type Integrated Enphase DC Connector Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight .92 kg(2.03 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power line Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio See the compatibility calculator at enphase.com/en-us/suppottimodule-compatibility. 2 Nominal voltage range can be extended beyond nominal if required by the utility. 3 Limits may vary_Refer to local requirements to define the number of microinverters per branch in your area To learn more about Enphase offerings,visit enphase.com 2038 nphase Energy Al-r ghts reserved Ali trademarks or b;ancs used are the property of Enphase:Energy,Inc 2 E N PHASE /\S E 20180.04 ['s D,ato Sheet Enphase Microinverters Region AMERICAS Enphase IQ 7+ Micros Designed for AC Module(ACM)applications,the smart /� grid-ready Enphase IQ 7+ACM MicroinverterTM is for AC IVIo d u l e built on the latest technology from Enphase.The high performance IQ Microinverters increase energy harvest Applications from PV modules while lowering system cost for installers. Part of the Enphase IQ System,the IQ 7+ACM microinverters are compatible with the Enphase IQ Envoy- and Enphase Enlighten- monitoring and analysis software. Enphase Microinverters set the highest benchmark in quality and reliability in the PV industry. Easy to install • Microinverter pre-mounted on PV modules for easy transport • and install • Fast installation with Enphase Q Cable • Built-in rapid shutdown compliant(NEC 2014&2017) Versatile and Reliable envwAse! io'147A-ail • Available through multiple module suppliers • Optimized for high powered 60-cell and begag 72-cell modules "'I • Adaptable for residential and commercial installations I a aJ� • Works with railless or traditional racking systems • Class II double-insulated enclosure .. _. • UL listed Smart Grid Ready • Complies with fixed power factor,voltage and frequency ride- through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) (11]) CERTIFIED SAFELY USIA E341165 ENP HAS E. To learn more about Enphase offerings,visit enphase.com Enphase IQ 7+ Microinverter for AC Module Application , INPUT DATA(DC) IQ7PLUS-72-ACM-US Commonly used module pairings' 235 W-440 W+ Module compatibility 60-cell and 72-cell PV modules Maximum input DC voltage 60 V Peak power tracking voltage 27 V-45 V Operating range 16 V-60 V Min/Max start voltage 22 V/60 V Max DC short circuit current(module Ise) 15 A Overvoltage class DC port I I DC port backfeed under single fault 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) Peak output power 295 VA Maximum continuous output power 290 VA Nominal(L-L)voltage/range2 240 V/211-264 V 208 V/183-229 V Maximum continuous output current 240 V:1.21 A 208 V:1.39 A Nominal frequency 60 Hz Extended frequency range 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms Maximum units per 20 A(L-L)branch circuit' 240 V:13 208 V:11 Overvoltage class AC port III AC port backfeed current 0 A Power factor setting 1.0 Power factor(adjustable) 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V Peak CEC efficiency 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connector type Integrated Enphase DC Connector Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight .92 kg(2.03 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category f UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power line Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at enohase.com/en-usisupport/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility_ 3.Limits may vary Refer to local requirements to define the number of mlcroinverters per branch in your area To learn more about Enphase offerings,visit enphase.com 7718 Enphase Energy At nghts res_r,ec, Ail rages-larks or 5ranas,Iscre are the property of Enphaso Energy,Inc EN P H AS E 201&06-D,1