Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit (3)
CITY OF TIGARD MASTER PERMIT III I ' COMMUNITY DEVELOPMENT Permit#: MST2019-00409 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 10/31/2019 T I[;A R o9 Parcel: 2S 111 CA09000 Jurisdiction: Tigard Site address: 9990 SW KABLE ST Subdivision: GULF SIDE ESTATES NO.2 A REPLAT OF" Lot: 34 Project: KENDRICK Project Description: Solar photovoltaic system. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $15,259.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: Y Other Description: Roof Top Solar PV 5.98 kW Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: KENDRICK,BRUCE J&JOANN BLUE RAVEN SOLAR LLC Required Items and Reports(Conditions) 9990 SW KABLE ST 1220 S 630 EAST,STE 430 TIGARD,OR 97224 AMERICAN FORK,UT 84003 PHONE: PHONE: 385-498-4408 FAX: Total Fees: $358.19 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow th-, rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952 0r r1:90. • ma,ain a ,• of •-rules or direct questions to OUNC by calling 503.232. •,7 or 1.800.332.2344. Issued By: ,41 , Permittee Signature: ./‘ 1//I0 r Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the pr.Ct. Approved plans are required on the job site at the time of each inspection. Building Permit Application Residential FOR OFFICE USE ONLY City of Tigard '; ceived If ,e te/By: Gb 3 , -).7:,.,_ Permit No./157-026V6/0407 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review ' Phone: 503.718.2439 Fax: 503.598.1960 ` it 2019 Date/By: lb 2.5272.5271 InspectionOther Permit: T I GA R[� Line: 503.639.4175OCT Date Re. y/By: i / Jurist See Page 2 for Internet: www.tigard-or.gov Noti�l/Method: I-- `�/ I Supplemental Information TYPE OF WORK , : 1 O N REQUIRED DATA:1-AND 2-FAMILY DWELLING 0 New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ` 0 Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. El I-and 2-family dwellingValuation: $ 15,259 0 Commercial/industrial ❑Accessory building 0 Multi-family Number of bedrooms: ElMaster builder 0 Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 9990 Southwest Kable Street,Tigard, Oregon,97224, United States New dwelling area: square feet City/State/ZIP: Garage/carport area: square feet Suite/bldg./apt.no.: Project name: Bruce Kendrick Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Rooftop Solar PV Valuation: $ S /c2� k Existing building area: square feet / cNew building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name: Bruce Kendrick Type of construction: Address:9990 Southwest Kable Street,Tigard,Oregon,97224,United States Occupancy groups: City/State/ZIP: Existing: Phone:( ) Fax:( ) New: 0 APPLICANT ®CONTACT PERSON BUILDING PERMIT FEES* Business name:Blue Raven Solar (Please refer to fee schedule) Structural plan review fee(or deposit): Contact name: Pica Nagano FLS plan review fee(if applicable): Address: 1403 N Research Way City/State/ZIP: Orem, UT 84097 Total fees due upon application: Phone:(385482-0045 Fax::( ) Amount received: E-mail: permitting.deparment@blueravensolar.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted Photo Voltaic Solar Panel System. Business name: Blue Raven Solar Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: 1403 N Research Way Solar Installation Specialty Code checklist. City/State/ZIP: Orem, UT 84097 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(385)482-0045 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lie.:210112 Total fee due upon application: $201.60 Authorized signature: faacL= This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: ,f effre Lee Date: 10/14/2019 *Fee methodology set by Tri-County Building Industry y Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Electrical Permit Application FOR OFFICE USE ONLY /p ,'Received City of Tigardry �,C F ,, ' 'Date/By: Permit#: � � 't 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review Phone: 503.718.2439 Fax: 503.598.1960OCT 22 7 19 Date/By: Related Permit#: Inspection Line: 503.639.4175 `� Ready Date/By: Juris: lif See Page 2 for TIGARD ® Internet: www.tigard-or.gov -y-�t OF ARF. Notified/Method: �tIi d Supplemental Information � TYPE OF W glt DING DIVISION PLAN REVIEW o New construction ©Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): 0 Service or feeder 400 amps or more 0 Building over three stories. ❑Demolition ❑Other: where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. Ea 1-and 2-familydwelling0 Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural ❑Commercial/industrialamps for all other installations. buildings. ❑Multi-family 0 Master builder 0 Other: 0 Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived Job#: Job site address: 9990 Southwest Kable Street, Tigard, ❑Addition of new motor load of system. 100HP or more. ❑"A","E","1-2","l-3", City/State/ZIP: 0 Six or more residential units. occupancy. ❑Health-care facilities. 0 Recreational vehicle parks. Suite/bldg./apt.#: Project name: Bruce Kendrick ❑Hazardous locations. 0 Supply voltage for more than 0 Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE Description I Qty. I Each I Total I * New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#: Ea add'l 500 sq.ft.or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential Rooftop Solar PV (with above sq.ft.) 75.00 2 Limited energy,multi-family 75.00 2 residential(with above sq.ft.) Renewable Energy 0 See Page 2 g PROPERTY OWNER 0 TENANT Services or feeders installation,alteration,and/or relocation Name: Bruce Kendrick 200 amps or less 100.70 2 Address: 9990 Southwest Kable Street,Tigard, Oregon,97224, United States 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: 601 amps to 1,000 amps 301.04 2 Phone:( ) Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 ® APPLICANT Branch circuits—new,alteration,or extension,per panel ❑ CONTACT PERSON A.Fee for branch circuits with Business name: Blue Raven Solar above service or feeder fee, 7.42 2 each branch circuit Contact name: Pica Nagano B.Fee for branch circuits without service or feeder fee,first Address: 1403 N Research Way branch circuit 56.18 2 City/State/ZIP: Orem, UT 84097 Each add'I branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:( 385)182-0045 Fax: : ( ) Each manufactured or modular dwelling,service and/or feeder 67.84 2 Email: permitting.department@blueravensola r.com Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name: Blue Raven Solar Sign or outline lighting 67.84 2 Address: 1403 N Research WaySignal ttt(s)or limited-energy 0 See Page 2 2 panel,alteration,or extension. City/State/ZIP: Orem, UT 84097 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:(385 482-0045 Fax:( ) /v ///22_ Investigation(1 hr min) 90.00/hr ,{�(y�� Industrial plant(1 hr min) 78.181 hr Email: permitting.department@blueravensolar.com Sr(S Inspections for which no fee is 90.00/hr CCB Lic.: 210112 Electrical Lic.: C1214 Suprv.Lic.: "6QJ/& specifically listed(%hr min) got l mW7t ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: Subtotal: Print name: Sam Collier Date: 10/14/2019 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: .11- TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name: Jeff Lee Date: 10/14/2019 days after it has been accepted as complete. * Number of inspections allowed per permit. L\Building\Pennits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 440-46151(11/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE I Fee for all residential systems combined: $75.00 Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 133.56 2 n Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: n Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 Ti Garage Door Opener* >100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 n Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 n Vacuum Systems* >100 kva-no additional charge 0.0 3 Each additional inspection over allowable in any of the above: Ti Other: Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed(%hr min) COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES Subtotal(Enter on Page 1): I Fee for each commercial system: $75.00 * Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems n Data Telecommunication Installation n Fire Alarm Installation n HVAC ❑ Instrumentation n Intercom and Paging Systems ❑ Landscape Irrigation Control* n Medical ❑ Nurse Calls n Outdoor Landscape Lighting* ❑ Protective Signaling Ti Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations i\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 Date: 10/16/2019 �,�, LD Permit#: ; �V Project Name: Bruce Kendrick OCT 22 2019 Address'. 990 Southwest Kable Street CITY OF IsGARD Tigard, Oregon 97224 UILD!NG DiVISIO Updated plans to show that a 60A AC Disconnect will be installed. Please reach out to me directly if you have any questions. Scott Gurney Engineering Sr. Manager engineering@blueravensolar. : 385-498-6700 The Future of Energy. Today. BLUE RAVEN y City of Tigard .111 Building Division ' . 13125 SW Hall Blvd, Tigard, OR 97223 VED Phone: 503.718.2439 Fax: 503.598.1960 TIGARD Inspection Line: 503.639.4175 OCT 9 2 2019 www.tigard-or.gov CITY OF TIGARD BUILDING 1iVISION 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 9990 Southwest Kable Street, Tigard, Oregon, 97224, Unite( City: Zip: Owner's Name: Bruce Kendrick Date: 10/14/2019 Contractor's Name: Blue Raven Solar CCB #: 210112 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation El Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? p No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure Yes If"Yes", qualifies for "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes L2 Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for Yes the prescriptive path. above ❑ No 1 I:/Building/Forms/Photo Voltaic-Checklist02-01-11.docx Is the construction IN material wood and does Yes Type of the construction qualify If"Yes", qualifies for Constructionas "conventional light ❑ No the prescriptive path. frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. L2 Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? If"Yes", qualifies for Nominal lumber. t2 Yes the prescriptive path. ❑ No Is the combined weight p Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance 0 Yes with Section 305.4(3) of If"Yes", qualifies for I I the 2010 Oregon Solar No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. 0 of composition shingle. Is the roof mounted Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for No the prescriptive path. to the roof framing or blocking directly? 2 I:/Building/Forms/Photo V oltaic-Checklist02-01-11.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for Yes the prescriptive path. No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for Yes the prescriptive path. No Attachment of roof mounted If the spacing falls Spacing of Minimum 24 inches within 24 inches and 60 solar systems p gclamps? directly to inches Maximum 60 inches inches, qualifies for the prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? Ti Yes the prescriptive path. No Is the roof decking of WSP min. 'A"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof 0 Yes the prescriptive path. surface. No 3 I:/Building/Forms/Photo Voltaic-Checklist02-01-11.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: JinKO Solar Eagle Model Number: Listing Agency: CSA 4 I:/Building/Forms/Photo Voltaic-Checklist02-01-11.docx