Loading...
Specifications /5875- S / ,74/s /h/e it/fC20/ - D072/3 oCT 22 ZO19 PNORTH aUiLDING 0, ��t: ION Mothers Milk Bank Walk-in Refrigeration Structural Calculations LOCATION Tigard, Oregon CLIENT Custom Cooler Inc. 19-1599 Or '- / i ` :4 '? r� V EXP/;ES: /_./W5-.4 Date Completed October 15,2019 Project Number 19028007 Engineer of Record Peter 0.Nussbacher P.E. Completed by Peter 0.Nussbacher P.E. Contact Peter@plan-north.com r (208)960-4719 .' PLAN NORTH ENGINEERS 1345 W BOBWHITE CT STE 200,BOISE ID 83706 PLA.NNORTH ENGINEERS TABLE OF CONTENTS 1-DESIGN CRITERIA 3 2-STRUCTURAL CALCULATIONS 5 2.1-PANEL CALCULATIONS 5 2.2-CONTINUOUS ANCHORAGE(SHEAR) 11 3-APPENDIX: MATERIAL SPECIFICATIONS 17 3.1-CUSTOM COOLER INC-LARR 25960 17 PLAN NORTH ENGINEERS 1345 W BOBWHITE CT,STE 200;BOISE ID 83706 2/21 P LAN NORTH ENGiNEERS 1- DESIGN CRITERIA CatHazards by Location tLo. Search Information is , Address: 15875 SW 74th Ave,Tigard,OR 97224,USA ay vaneguver P Coordinates: 45,4051079,-122.75249839999998 Tillamook Htlisboroo and State Forest Bea en Gresham Elevation: ft riS3 Mt Hot Timestamp: 2019-10-14T22:40:59.1472 National F Hazard Type: Seismic .rty Reference ASCE7-10 Go ,gie Map data 02019(too* Document: Risk Category: II Site Class: MCER Horizontal Response Spectrum Design Horizontal Response Spectrum SaW) Sa(9) 1.00 0.60 0.80 0.60 0.40 0.40 0.20 0.20 0.00 0.00 0 5 10 15 Periods) 0 5 10 15 Period(5) Basic Parameters Name Value Description Ss 0.965 MCER ground motion(period=0.2s) Si 0.419 MCER ground motion(period=1.0s) Skis 1.075 Site-modified spectral acceleration value Smi 0.663 Site-modified spectral acceleration value SOS 0.717 Numeric seismic design value at 0.2s SA Sol 0.442 Numeric seismic design value at 1.0s SA ',Additional Information Name Value Description SDC 0 Seismic design category 1.114 Site amplification factor at 0.2s 1.581 Site amplification factor at 1.08 CRs 0.896 Coefficient of risk(0.2s) r,f1 "0.7 PLAN NORTH ENGINEERS 1345 W BOBWHITE CT,STE 200.BOISE ID 83706 3/21 PLAN NORTH ENGINEERS Ve.41 Ill•?aft%, • PGA 0.422 MCE6 peak ground acceleration FPGA 1,078 Site amplification factor at PGA PGA m 0.455 Site modified peak ground acceleration TL 16 Long-period transition period(s) SsRT 0.965 Probabilistic risk-targeted ground motion(0.2s) SsUH 1.077 Factored uniform-hazard spectral acceleration(2%probability of exceedance in 50 years) SsD 2.195 Factored deterministic acceleration value(0.2s) S1RT 0.419 Probabilistic risk-targeted ground motion(1.0s) S1UH 0.481 Factored uniform-hazard spectral acceleration(2%probability of exceedance in 50 years) Sit) 0.722 Factored deterministic acceleration value(1.0s) PGAd 0,8 Factored deterministic acceleration value(PGA) The results indicated here DO NOT retied any state or local amendments to the values or any delineation lines made during the building code adoption process.Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design, Disclaimer Hazard loads are provided by the U.S.Geological Survey Seismic Design Web Services. While the information presented on this website is believed to be correct,ATC and its sponsors and contributors assume no responsibility or liability for its accuracy.The material presented in the report should not be used or relied upon for any specific application without competent examination and verification of its accuracy,suitability and applicability by engineers or other licensed professionals.ATC does not intend that the use of this information replace the sound judgment of such competent professionals,having experience and knowledge in the field of practice,nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website.Users of the information from this website assume all liability arising from such use.Use of the output of this website does not imply approval by the governing budding code bodies responsible for budding code approval and interpretation for the building site described by latitudeflongitude location in the report. PLAN NORTH ENGINEERS 345W1BOBWHITE CT,STE 200,BOISE ID 83706 4/21 PLANNORTH ENGiNEEPS 2- STRUCTURAL CALCULATIONS 2,1- PANEL CALCULATIONS PROJECT INFORMATION CLIENT: CUSTOM COOLER,INC PANEL INFORMATION: LARR#25690-CUSTOM COOLER INCORPORATED PREFABRICATED MODEL 300 REFRIGERATION PANELS FOR WALK-IN COOLERS AND FREEZERS. SCOPE OF WORK: STRUCTURAL DESIGN OF PREMANUFACTURED INSULATED PANELS AND THEIR ANCHORAGE TO THE FOUNDATION SYSTEM. IF REO'D,CAPACITY OF THE EXISTING STRUCTURE IS TO BE PROVIDED BY OWNER'S REPRESENTATIVE, DESIGN OF STRUCTURAL ELEMENTS SUPPORTING PANELS. JURISDICTION: OREGON STRUCTURAL CODE: 2014 OSSC(REF ASCE 7-10) WALK-IN GEOMETRIC INFORMATION CEILING PANEL THICKNESS: 5 in MEDIAN HEIGHT: 10.0 ft WALL PANEL THICKNESS: 4 in WALL PANEL HEIGHT: 9.2 ft PANEL LOAD DATA CEILING PANEL LOADS WALL PANEL LOADS PANEL WEIGHT: 4 psf PANEL WEIGHT: 3.5 psf CEILING COVERING: 0 psf WALL COVERING: 0 psf MISC.WIEGHT: 1 psf MISC.WIEGHT 1 psf TOTAL DEAD LOAD: 5 psf TOTAL DEAD LOAD: 4.5 psi CEILING LIVE LOAD: 10 psf 1 WALL LIVE LOAD*:I 5 psi *Min lateral(1607,14) SEISMIC LOADS MAPPED MCE (0.2s PERIOD),S s: 0.965 g MAPPED MCE R (1.0s PERIOD), : 0.419 g SITE AMP FACTOR,Fa: 1.114 s SITE AMP FACTOR,F 1.581 s DESIGN VALUE(0.2s PERIOD),S Ds: 0.717 g DESIGN VALUE(1.05 PERIOD),S DI: 0.44 g Lateral Force Generation: Shear wails BUILDING TYPE: Nonbuilding structure similar to building(ASCE 7,Ch.15) ANALYSIS PROCEDURE: Per 15.1.3,Equivalent Lateral Force Procedure(ASCE 7 Ch 12) RESPONSE MOD FACTOR,R: 2.0 (Table 12,2-1,No.17) (TABLE 12.8-2) SEISMIC IMPORTANCE FACTOR,Ie: 1.0 C, h APPROX FUNDAMENTAL PRD, : 0.112 s (To„=C,x h ) 0,02 10.0 0.75 (12.8.1.1) RESPONSE COEFFICIENT,C s:I 0.358 g S os EQUATION C s: 0.358 (Rile) MIN C s 0,032 *Note:See lateral analysis section for seismic load distribution MAX C s: 1.963 PLAN NORTH ENGINEERS I 345 W BOBWHITE CT,STE 200,BOISE ID 83706 5/21 P LA N NORTH ENGINEERS INDOOR PANEL CAPACITY CEILING PANEL LENGTH,L: 15.4 ft FRAME TYPE: WOOD WIDTH,b: 47 in ALLOWABLE LOAD,P: 42.1 psf x L2 ALLOWABLE MOMENT: 4888.2 lbrft M = APPLIED LOADS: D 1 psf 'miscellaneous Lr 10 psf NA W NA NOT USED: APPLIED MOMENT: 1277.2 Ibrft D+(Lr,S) `ALLOWABLE>APPLIED:PANEL Or WALL PANEL HEIGHT,h: 9.2 ft FRAME TYPE: HDR WIDTH,b: 47 in ALLOWABLE TRANSVERSE LOAD: 52.5 psf ALLOWABLE MOMENT. 2169,6 ibrtt APPLIED LOADS: ALLOWABLE AXIAL LOAD: 300 plf TRANS LOAD D 0.0 psf L 5.0 psf W 0.0 psf APPLIED MOMENT: 206.6 but D+L NOT USED: REACTION ON WALL CONNECTIONS: 23.0 elf *ALLOWABLE>APPLIED:PANEL Or AXIAL LOAD AXIAL TRIB 7.7 ft D 38.5 plf Ceiling panel Lr 77.0 plf 0 plf NET UPLIFT 0 plf_ APPLIED AXIAL LOAD: 115.5 plf D+(Lr,S) 'ALLOWABLE>APPLIED:PANEL Or COMBINED STRESS RATIO: 0 480 0+(Lr,S) 'COMBINED STRESS<1.0:PANEL OK' PLAN NORTH ENGINEERS 345 W BOBWHITE CT,STE 200,BOISE ID 83706 6/21 • PLANNORTH ENGINEERS PANEL CONNECTION CAPACITY Wall to Ceiling Capacity CONNECTION TYPE: LAG DOWN DETAIL 21 FASTENER SPACING: 23.3 in WALL TO CEILING CAPACITY SUMMARY* ALLOWABLE ALLOWABLE SHEAR UNIT LOAD TENSION UNIT LOAD LAG SCREW: 573.0 Ibf 295.7 plf 472.0 lbf 243,6 plf OUT-OF-PLANE WALL REACTION: *OK* 23.0 ptf D+L IN-PLANE WALL REAC770N: *OK* 22.2 pff Lateral analysis: CEILING A,E-W: MAXIMUM UPLIFT: *OK* 0.0 plf No Uplift Present *Reference LARR#25690 7-E SCREW CAPACITY LOCATION: Continuous angle vertical leg at wall base screw into panel-Detail 3 SCREW (LRFD) MAIN PENETRATION: 1.5 in WOOD SPECIES: DF-L LRFD CONV,FACTOR,(KFxcp): 2.158 0 REF DESIGN VALUE*: 145.2 Ibf ALLOWABLE SHEAR: 313.3 lbf MAX SHEAR*: 89.5 lbf *OK* WDS-TABLE 12.3.1A *reference lateral analysis for loads REF DESIGN VALUE,W/DRAW*: 172 Ibifin ALLOWABLE WIDRAW: 556.8 lbf *reference NDS-Table 122B PLAN NORTH ENGINEERS I 345W BOBWHITE CT,STE 200 BOISE ID 83706 7/21 PLAN NORTH ENCtNEEPS GRIDLINE&LATERAL LAYOUT • (1.0L Ref 1607.14) UNIT SHEAR ASD SEISMIC MIN INDOOR WIDTH DEPTH CAPACITY DEAD LOAD,0 LOAD,0.7(DxC s) LATERAL LOAD CEILING 1,N-S: 15.4 ft 20,0 ft 292.0 Of 1540.0 Ibf 386.3 Ibf 45.9 plf CEILING A,E-W: 20.0 ft 15.4 ft _ 160.0 Of 1540.0 Ibf 386.3 Ibf 45.9 plf TOTAL LENGTH HEIGHT GRIDLINE 1: 20.0 ft 9,1:: ft 826.9 lbf 207,4 Ibf GRIDLINE 2: 20,0 ft 9.1:: ft 826.9 lbf 2074 Ibf GRIDLINE A: 15,4 ft 9.168 ft 636.7 lbf 159.7 Ibf GRIDLINE B: 15.4 ft 9.168 ft 636.7 lbf 159.7 Ibf *Unit shear capacity depends on pane!span direction. Reference aspect ratio WID(diaphragms)in approval for panel spans transverse to loading direction. See appendix for reference capacity. TAL4,-; E 1' , d144.'t:t 4"1 PANEL CAPACITY PROCEDURE: N-S DIRECTION- WID aspect ratio applies to the total unit dimensions for load application. Chord forces are accounted for in allowable loads. Reference approval report in appendix for table of allowable loads with respect to aspect ratio. Shear walls provide in-plane support at Gridlines 1&2. E-W DIRECT/ON- WID aspect ratio applies to the total unit dimensions for load application. Chord forces are accounted for in allowable loads. Reference approval report in appendix for table of allowable loads with respect to aspect ratio. Shear walls provide in-plane support at Gridlines A&B. PLAN NORTH ENGINEERS 345W1BOBWHITE CT,STE 200,BOISE ID 83706 8/21 • PLANNORTH LATERAL LOAD DISTRIBUTION 1------- Lateral Load Summary at Ceiling Diaphragms TRIBUTARY TRIBUTARY ASO MINIMUM ASO UNIT SEISMIC LOADLATERAL LOAD CHORD FORCE SHEAR CEILING 1,N-S: 614,4 ibf 353.7 lbf *Seismic Governs* NA 15.4 pit *OK* CEILING A,E-W: 682.6 Ibf 459.4 Ibf *Seismic Governs" NA 22,2 pif *DK. *includes load due to out of plane wall length ILateral Load Summary at Shear Resisting Elements SHORT ELEMENT SEGMENT UNIT SHEAR TYPE LENGTH,L CAPACITY'S is SHEAR APPLIED ASO UNIT SEGMENTS SHEAR' GRIDLINE 1: SW 20.0 ft 400.0 pit 20.0 ft 25.7 pif *Applied Load<Allowable* GRIDLINE 2: SW 20.0 ft . 400.0 pit 20.0 ft 25.7 pit 'Applied Load<Allowable' GRIDLINE A: SW 6.2 ft 135.4 pit 12,4 ft 40.4 Of *Applied Load<Allowable* GRIDLINE B: SW 6..2 ft 135.4 pit 12.4 ft 40.4 pit *Applied Load<Allowable' SW--,Shear Wall MF-Moment Frame *Unit shear capacity based aspect ratio HIL(walls). Shear wall capacity determined using shortest length of segment on gridline, - 'Unit shear due to seismic load includes gridline self weight when seismic governs. Calculated using net load from ceiling diaphragms above divided by sum of shear segment lengths, ISW Wall Overturning Force - ; CEILING WEIGHT,F3 ; ymA.0= —Fl(H)+14.3 Gil+F;( )+F4(L)+Mao L 4 L\LATERAL LOAD,Fl Mnet =F1(K)—F2(-2)—F3(7 —F4(L) t— i 4 I ,/ WALL WEIGHT.F4 ..= M (X) F h = y-anc or zx2 where,X=distance from centroid gI of waif to each anchor i WALL WEIGHT,F2 J ,,-- IliF A lir8.FrA Ng s NETC ' \A"-----* LENGTH,L.ift)-----* IB WIDTH,WI MOMENT,Mnet an PANEL AREA RESISTING 11111111 OT FORCES NOTE: ANCHORAGE FORCE,F,„00,..,CALCULATED USING THE ROTATIONAL MOMENT OF INERTIA ABOUT THE CENTROID OF THE CONTINUOUS ANCHORAGE LINE AT Li2, OVERTURNING FORCES DETERMINED USING STRENGTH LEVEL LOADS FOR COMPATIBILITY WITH CONCRETE ANCHORS, ..., • PLAN NORTH ENGINEERS I 345W BOBWHITE CT,STE 200,BOISE ID 83706 9121 • PLANNORTH ENGINEERS OT RESISTING RESISTING RESISTING • OT FORCE, MOMENT, MOMENT, F 3 TRIB MOMENT, F TRIB MOMENT, Ft F x(h) F x(L/2) WIDTH,W t F 41/2) WIDTH,W1 F 4 x(L) NET OTM" GRIDLINE 1: 735,2 Ibf 6.8 kip*ft 6.3 kip*ft 7,7 ft 9.2 kip'ft 7.7 ft 7.6 kip'ft -16.4 kip*ft GRIDLINE 2: 735.2 Ibf 6,8 kip'ft 6.3 kirft 7,7 ft 9.2 kip*ft 7.7 ft 7.6 kip*ft -16.4 kip'ft GRIDLINE A: 357,9 Ibf 3.3 kip*ft 0.6 kip'ft 10.0 ft 1.2 kip'ft 10.0 ft 3.1 kip'ft -1.5 kip'ft GRIDLINE 357,9 Ibf 3.3 kip*ft 0.6 kirft 10,0 ft 1.2 kip*ft 10,0 ft 3,1 kip'ft -1.5 kip'ft 'Negative Net OTM indicates no overturning is present Reference short segment length and unit shear above Continuous Anchorage Forces at Shearwalls HORIZONTAL LEG ANCHOR FORCES VERTICAL LEG FASTENER FORCES Horizontal Vertical Horizontal Vertical Resultant Anchor X 2 From Comp.per Comp.per Fastener I X2 From Comp.per Comp.per Shear Spacing Centrad Anchor,F, Anchor,F y Spacing Centroid Anchor,F, Anchor,F (SRSS) GRIDLINE 1: 2.0 ft NA 66.8 Ibf NA 2.00 ft NA 66.83 Ibf NA GRIDLINE2; 2,0 ft _ NA 66.8 Ibf NA 2.00 ft NA 66.83 Ibf NA GRIDLINE A: 2,0 ft NA 89,5 Ibf NA 2.00 ft NA 89.46 Ibf NA GRIDLINE B. 2.0 ft NA 89,5 Ibf NA 2,00 ft NA 89.46 Ibf NA GRIDLINE I SUMMARY: NO OVERTURNING PRESENT.ANCHORAGE CAN RESIST Fx FORCES. GRIDLINE 2 SUMMARY: NO OVERTURNING PRESENT,ANCHORAGE CAN RESIST Fx FORCES. GRIDLINE A SUMMARY: NO OVERTURNING PRESENT.ANCHORAGE CAN RESIST Fx FORCES. GRIDLINE 8 SUMMARY: NO OVERTURNING PRESENT.ANCHORAGE CAN RESIST Fx FORCES. *trii,,,Ng40-4,0**101. PLAN NORTH ENGINEERS 1346 W BOBWHITE CT.STE 200.BOISE ID 83706 21 PLANNORTH ENGINEERS 2.2- CONTINUOUS ANCHORAGE(SHEAR) 1411116,11r1111 Hilti PROFIS Engineering 3.0.44 www.hilti.com Company: Page. 1 Address: Specifier: Phone I Fax- Design: Date: 6/27/2019 Fastening point; Specifier's comments: 1 Input data ..w*Moyne001" .10.1"....g.mawqm. Anchor type and diameter: KWIK HUS-EZ(KH-EZ)1/4(1 5/8) exim arm sem mar era Item number: not available Effective embedment depth: h.taa.1.180 in.,h 1,625 in. Material: Carton Steel Evaluation Service Report: ESR-3027 Issued I Valid; 6/112018 112/1/2019 ProofDesign Method AC1 318-11/Med), Stand-off installation' =0.000 in.(no stand-off);t 0.118 in. Anchor plate: tx tx1=1.500 in.x 24.000 in.x 0.118 in.:(Recommended plate thickness:not calculated) Profile; no profile Base matenal; cracked concrete,2500,f‘'=2,500 psi;h=4.000 in. Installation: hammer drilled hole,Installation condition:Dry Reinforcement tension;condition 8,shear;condition Et;no supplemental splitting reinforcement present edge reinforcement:none or<No.4 bar Seismic loads(cat.C,0,E,or F) Tension load:yes(D.3.3.4.3(b)) Shear load:yes(0.3.3.5.3(a)) R- The anchor calculation is based on a rigid anchor plate assumption. Geometry(ml&Loading[lb,Intl)] M ":;:e;r000,„,„ 114", 1APX d4tatx,,d resale mkt be ohedted to conformity ACM the extoting concritione arrel befikunikthri snore ringinieamog r I 2003-2515 It AG,FbRibiR$01,Amn 551 4*414(.444 Til*/***44 040 AG,S044* " PLAN NORTH ENGINEERS 1345 W BOBWHITE CT,STE 200.BOISE Id 83706 11121 P LA NNORTH ENc! NEEps HOU PROFIS Engineering 3.0.44 Company: Page: 2 Address: Specifier: Phone I Fax: E-Mail: Design: Date: 6/27/2019 Fastening point: 11 Design results Case Description Forces[113)I Moments(MA] Seismic Max.VW.Anchor[°/.] 1 Combination 1 N 0;Vy 0;V =760; no 100 M,=0;My= M,=0; 2 Load case/Resulting anchor forces Load case:Design loads MAXIMUM SHEAR LOAD FOR ANCHOR Anchor reactions(lb] Tension force:(+Tension„-Compresiinn) Anchor Tension force Shear force Shear force x Shear force y 1 0 760 0 760 max,concrete compressive strain: -rbid max,concrete compressive stress; -[PA resulting tension force in(x/y)=(0.000/0.000): 0[Ib] resulting compression force in fx/y),(0.000/0.000):011131 Anchor forces are calculated based on the assumption of a rigid anchor plate. 3 Tension load Load Nn„0b1 Capacity+N„pill Utilization 0,•NJ+No Status Steel Strength' N/A N/A NIA N/A Pullout Strength' N/A N/A N/A N/A Concrete Breakout Failure— N/A N/A N/A N/A •highest loaded anchor "anchor group(anchors in tension) irtpix rise ane results must be checited be contbernIty velb lbe eststIng cum:Minns sob fur plaustbattyl PROF IS ErGineeting(c I 20032018 an AG, 43494 Sristusl 1141 C11 tegiStered itactemerk 01.11111AG,Schism 2 PLAN NORTH ENGINEERS 345 W BOBWHITE CT,STE 200,BOISE ID 83706 12/21 PLANNORTH ENGINEERS 114161119 HIM PROM Engineering 3.044 www.hiltt.com Company: Page: 3 Address: Specifier' Phone I Fax: E-Mail: Design: Date: 6127/2019 Fastening point: 4 Shear load Load V [lbj Capacity 4 V, Ib] Utilization(iv=V„.4 V, Status Steel Strength* 760 637 91 OK Steel failure(with lever arm)* N/A N/A Frye:aft Strength** 760 763 100 OK Concrete edge failure in direction** N/A N/A NIA *highest loaded anchor **anchor group(relevant anchors) 4.1 Steel Strength =ESR value refer to ICC-ES ESR-3027 ACI 318-11 Table 04 1.1 Variables ',say fin. f fPnli 0.05 125,000 Calculations lib) 1,395 Results nbi Clooduale • [Ib] V [MI 1,395 0.600 1.000 837 760 but data area results must be checked tot cardotandyeathareeNsting eabsearts and far tstausatety! PROF IS Enable/ONI 2003.2019 IsA0 Fl.9494 Stnnan H0 eetagett Tradearete eflilib AG Crease 3 PLAN NORTH ENGINEERS 345W1BOBWHITE CT,STE 200,BOISE ID 83706 13/21 PLANNORTH ENCINEEPS 111111M111111 I HiltPROM Engineering 3.0.44 www.hilti.com Company: Page: 4 Address: Specifier Phone I Fax: E-MaiL Design: Date: 5/27/2014 Fastening point: 4.2 Pryout Strength = „0,atop eh„,N Nj EG)Nkw co ACI 318-11 Eq.(D-40) VV ACI 318-11 Table 0.4.1.1 A,4, see ACI 318-11,Part 0,5.2.1,Fig.RD.5.2.1(b) A =9h ACI 318-11 Eq.(0-5) Nis 44, =0.7 0.3(AT—:r)C 1.0 ACI 318-11 Eq.(D-10) MAX 1.0 ACi 318-11 Eq.(0-12) Nb. = b -11 h:es AC1 318-11 Eq.(0-6) Variables kqa hor Da-1 Fin] ..tq 1 1,180 1.000 c.Pal 20. fctPJ 2.000 17 1,000 2.500 Calculations AN c fi1 AIfli No Obi 12.53 12.53 1 000 1.000 1,090 Results V.[lb] #.„,„„,„ V,[Ib] V,0[IN 1,090 0.700 1 000 1.00(1 763 760 Win data and results be oNttkadbr MIPOITTlity Vigh be ebrebuconditions end br piaus.dirtid PROPS Eftglne*Filv g )2.003,,2318 Mn AG,FL-9494 Solan 1M.4 rogoo944ti TqulooNg% Hilt AG ethaan 4 • PLANNORTH ENGINES Pt 111111111411rIl Hilti PROFIS Engineering 3.0.44 ws•inv.hilticom Company: Page; Address: Specifier Phone I Fax: E-Mail: Design Date: 612712019 Fastening point: 5 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations(AS 5218:2018,ETAG 001/Annex C, EOTA TR029 etc.).This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered-the anchor plate is assumed to be sufficiently stiff,in order not to be deformed when subjected to the design loading,PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above,The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering, Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies where the potential concrete failure surfaces we crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member.Condition B applies where such supplementary reinforcement is not provided,or where pullout or pryout strength governs. • Refer to the manufacturers product literature for cleaning and installation instructions. • For additional Information about ACI 318 strength design provisions,please go to https://submittals.us.hlitl.corn/PROFISArichorDesignGuide/ • An anchor design approach for structures assigned to Seismic Design Category C,0, E or F is given in ACI 318-11 Appendix D,Part D.3.3.4.3 (a)that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure,If this is NOT the case,the connection design(tension)shall satisfy the provisions of Part D3.3.4.3(b),Part 0.3.3.4.3(c),or Part 0.3.34.3(c)_The connection design (shear)shall satisfy the provisions of Part 0.3.3.5.3(a),Part 0,13.5.3(b),or Part D.335.3(c) • Part 0.3.3.4.3(b)/part 0.3.3.5.3(a)require the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength.Part 0.3.3.4.3(c)I part 0.3.3.5.3(b)waive the ductility requirements and require the anchors to be designed for the maximum tension I shear that can be transmitted to the anchors by a non-yielding attachment,Part 0.3.3.4.3(d)/part D.3.3.5.3(c)waive the ductility requirements and require the design strength of the anchors to equal or exceed the maximum tension/shear obtained from design load combinations that include E,with E increased by tic,. • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturers Printed Installation Instructions(UPI!).Reference ACI 318-Il,Part D.9.1 Fastening meets the design criteria! lAput dais am results maw be decked for LONOrlity.1h The extong canaelons ass!sr pieruubilityl PROF IS Ss5inevraig III?003-7018-bill 0.FL.9494 ScA&An HMI as ht9istlerd Troderror% HIIII AG,Sawn 5 PLAN NORTH ENGINEERS I 345 W BOBWHITE CT,STE 200,BOISE ID 83706 15/21 PLANNORTH ENG1NEEns . IMILT911 Hilti PROM Engineering 3.0.44 www.hilti.com Company: Page: a Address: Specifier: Phone I Fax: &Mail: Design' Date: 6(271201g Fastening point: 6 Installation data Anchor type and diameter.KWIK HUS-EZ(KH-EZ)1/4(1 5/8) Profile:no profile Item number:not available Hole diameter in the fixture;di=0.375 in. Installation torque:216 in.lb Plate thickness(input):0.118 in. Hole diameter in the base material:0.250 in. Recommended plate thickness:not calculated Hole depth in the base material:1.836 In. Drilling method:Hammer drilled Minimum thickness of the base material:3.250 in. Cleaning:Manual cleaning of the drilled hole according to instructions for use is required. Hilt KH-EZ screw anchor with 1.625 in embedment,1/4(1 5/8),Carbon steel,installation per ESR-3027 6.°1 Recommended accessories Drilling Cleaning Setting - Suitable Rotary Hammer - Manual blow-out pump • Torque wrench • Property sized drill bit Y 0 II 11 x 1 131!i'e° Coordinates Anchor in. Anchor x y c_. c, Cr c„ 1 0.000 0.000 - - - [ANA data and results must be checked kw ossfsrendy solh die exlidting son:alms and far plausbadyt PROFIS E,sin -,-d c 1 WOS,2018 lied AG,FL,9494&a, - HIV is a ross*stensd Tradewmark OM At..Sctsan 6 PLAN NORTH ENGINEERS i 345 W BOBWHITE CT,STE 200,BOISE ID 83706 16/21 P LANNORTH ENGINEERS 3- APPENDIX: MATERIAL SPECIFICATIONS 3.1- CUSTOM COOLER INC-LARR 25960 CITY OF Los ANGELES 0440 04 DEPARTMENT OF BUILDING AND SAFETY CALIFORNIA BUILDING AND SAFETY COMMISSIONERS NOR I T IcAERGA STREET LOS',MALES CA ED012 VAN AMBATIELOS IIIIlII PRESIDENT rlpi FRANK M.BUSH E.FELICIA BRANNON ip MANAGER WU.PRESIDENT SUPERINTENDENT OF 131.11LOING JOSELYN GEAGA-ROSENTHAL ERIC GARCETTI OSAMA YOUNAN,PC. GEORGE HOVAGUIMIAN EXECUTIVE OFFICER JAVIER NUNEZ CCI Global LLC,DBA Custom Cooler A KPS Global Company RESEARCH REPORT:RR 25690 420 East Arrow Hwy (CSI#13030) • San Dimas,CA 91773 Expires: December 1,2020 Attn:Steve Pearson Issued Date: February 1,2019 (909)592-1111 Code: 2017 LABC GENERAL APPROVAL—Clerical Modification-Custom Cooler Incorporated Prefabricated Model 300 Refrigeration Panels for Walk-In Coolers and Freezers. DETAILS The panels consist of 3-1/2"to 5-1/2"thick high density foam or wooden frames with foamed-in- place rigid plastic core material manufactured by Dow Chemical Company and designated as: Voracor CE108,CE151,CE153,CE128,CE155,CE152,CE157"A"side. Delta Therm AF4509 or Voracor CRI004"B"side. The skins are fabricated from 26 gauge galvanized steel with a minimum yield strength 33 ksi. The panels are held together by the use of cam-locking devises along the edges of the panels. Access holes for these devices are covered with metal or plastic plugs.Flame Spread and Smoke Development ratings per ASTM E84 are 20 and 300 respectively,for the foam(tested alone)and 15 and 250 respectively,for the foam with the skin described below.Density of the foam core is 2.2+or-.2 pcf. Custom Cooler Incorporated freestanding walk-in coolers and freezers constructed of panels described above are approved subject to the following conditions: I. Use of the panels shall be limited to locations where combustible construction is permitted by the 2017 Los Angeles City Building Code. 2. The panels shall be fabricated in a shop of a licensed fabricator approved by the Los Angeles City Building&Safety Department.Fabrication in unlicensed shops will invalidate this approval. RR 25690 Page 1 of 5 LAMS 0-5(FIA.04/30r2014) AN EQUAL EMPLOYMENT OPPORTUNITY AFFIRMATIVE ACTION EMPLOYER PLAN NORTH ENGINEERS 345 VV BOBWHITE CT,STE 200,BOISE ID 83706 17/21 PLANNORTH ENGINEERS CCI Global LLC,DBA Custom Cooler a KPS Global Company Re:Custom Cooler Incorporated Prefabricated Model Refrigeration Panels for Walk-in Coolers and Freezers 3. A thermal barrier is required per Section 2603.4 of the 2017 Los Angeles City Building Code unless exempted per Section 2603.4.1. 4. Complete plans and calculations,signed and stamped by a civil or structural engineer or architect registered in the State of California,shall be submitted to the Structural Plan Check for their approval for each job. 5. An approved fire retardant roof covering(Class"A"or"B")shall be placed over the panels when used as exterior roof panels. 6. A separate approval from the Electrical Testing Laboratory shall be required for electrical installations within the panels. 7. Design of building utilizing the panels shall be in accordance with the requirements of the 2017 Los Angeles City Building Code and the design data specified A.Panel Height Limitation(feet)and Maximum Concentric Axial Loads(PLF) Thickness Interior Panels Exterior Panels Maximum Axial (20 lb/sqft) Load(PLF) 4"wood Frame 30 18 600 4"foam Frame 24 13 300 5"wood Frame 31 20 600 5"foam Frame 2 14 300 6"wood Frame 32 2 I 600 6"foam Frame 3u 15 300 RR 25690 Page 2 of 5 PLAN NORTH ENGINEERS 345 W BOBWHITE CT,STE 200.BOISE ID 83706 18 121 PLANNORTH ENGINEERS CCI Global LLC,DBA Custom Cooler a KPS Global Company Re:Custom Cooler Incorporated Prefabricated Model Refrigeration Panels for Walk-in Coolers and Freezers B. Maximum Allowable Loads for Roof or Ceiling Panels (W/F=Wood Frame)(FR=Foam Frame) Span t=4 in,W/F t 4 in.FiF t=5 in.W.+ t=51n.FIF t=6 in.Wit` t=6 in.FT 10 53 49 65 65 79 79 12' 50 36 55 48 66 62 14' 37 27 47 37 57 48 16' 28 20 40 29 50 38 18' 22 16 32 23 42 30 20' 18 13 25 18 34 24 22' 14 10 20 15 27 20 24' 11 8 17 12 23 16 26' 9 7 14 10 19 13 28' 8 6 11 8 16 11 30' 6 10 7 13 10 32' 9 6 11 8 C. Maximum Allowable Shear Load of Wall Panels(PLF): Shape Factor(Height:Width)Ratio Allowable Shear(ppf) 05:1 400 1:1 200 1.5:1 133 2:1 100 D. Maximum Allowable Roof/Ceiling Diaphragm Shear Shape Factor(Height:Width)Ratio Allowable Shear(ppf) 0.5.1 400 1:1 200 1.5:1 133 2.1 100 3:1 MAXIMUM 67 RR 25690 Page 3 of 5 PLAN NORTH ENGINEERS 345W1BOBWHITE CT,STE 200.BOISE ID 83706 19/21 PLANNORTH ENGINEERS CCI Global LLC,DBA Custom Cooler a KPS Global Company Re:Custom Cooler Incorporated Prefabricated Model Refrigeration Panels for Walk-in Coolers and Freezers The panels shall be continuous between exterior shear walls and shall not contain any openings or holes. E. Ceiling panel to wall panel connections are made with 3/8"dia.Lag screws or cam- locking devises,then a 26 gauge galvanized continuance angle cap is installed using#8 x 5/8"long tek screws(see attachment 1).The allowable shear and tension loads for the lag bolt connection are 573 and 472 pounds respectively.The allowable shear and tension loads for the camlock connection are 464 and 123 pounds respectively. F. Maximum Allowable Loading for the Cam-Locking Devices: Wood Frame Foam Frame Tension parallel to panel face 386 168 Shear along longitudinal edge of panel in 280 147 direction parallel to panel edge 8. Locations of connectors must be detailed on approved plans,the spacing of connections shall be calculated for each job but not less than two per width of panel(Width of panel= 46 1/2"). 9. Allowable loads for shear walls and diaphragms are not applicable to buildings incorporating structural steel framing. 10. No increase in allowable stresses is allowed for the values indicated above for short duration of loads due to wind or seismic forces. 11. All design values and methods not included in this report shall be in accordance with requirements of the 2017 Angeles City Building Code. DISCUSSION The clerical modification is to recognize a new petitioner for this general approval. The report is in compliance with the 2017 Los Angeles City Building Code. The approval is based on tests on the foam per requirements of Sec.2603 of the 2017 Los Angeles City Building Code,tests conducted in accordance with ASTM E-84 on the finished panels,and load tests conducted in accordance with ASTM E-72. Addressee to whom this Research Report is issued is responsible for providing copies of it, let-un with an attachm.nts in,i s to architects,engineers and builders using items approved herein in design or construction which must be approved by Department of Building and Safety Engineers and Inspectors. RR 25690 Page 4 of 5 PLAN NORTH ENGINEERS I 345 W BOBWHITE CT.STE 200.BOISE ID 83706 20121 PLAN NORTH ENGEES CCI Global LLC,DBA Custom Cooler a KPS Global Company Re:Custom Cooler Incorporated Prefabricated Model Refrigeration Panels for Walk-in Coolers and Freezers This general approval of an equivalent alternate to the Code is only valid where an engineer and/or inspector of this Department has determined that all conditions of this Approval have been met in the project in which it is to be used, DAVID CHANG,Chief Engineering Research Section 201 N.Figueroa St.,Room 880 Los Angeles,CA 90012 Phone-213-202-9816 Fax-213-202-9943 ER 10.2.5640 7L81900017 • R02,041019 2601 Attachment:Panel Connection Detail(2 Pages). RR 25690 Page 5 of 5 PLAN NORTH ENGINEERS 345 W BOBWHITE CT STE 200 BOISE ID 83706 21/21