Loading...
Plans t OFFICE COPY N. . . 4 '' z°,gROLLINGS RESIDENCEl r ;AR ei L. PHOTOVOLTAIC ARRAY 31.1ILDING DtViSION 7.475 kW, 23 @ 325W PANASONIC/ENPHASE (C,‘,.c '„.,,,,_„, Approved plans shall be on job site. CUSTOMER LAURI A & JOEL M ROLLINGS 6-- 16842 SOUTHWEST BIRDSONG STREET TIGARD, OR 97007 CITY OF TIGARD p 00 REVIEWED FOR E COMPLIANCILi �f� v ~ >� 414-902-0303 Approved: I z W av Iauri.rollin s@ mail.com OTC: ' W � W 4 g g Permit #: S(a blq --001-( g °C ' °v Address: 1,terbL(1 ,5W �, tl z k aL �J.jj J Qw Suite #: 0m O CONTRACTOR AURIC ENERGY By: — Date: 17 t1 cc 17'w v t T,_ 2310 SOUTH 1300 WEST D , v ai WEST VALLEY CITY, UT 84119 VALIDITY OF PERMIT 801-878-3363 LIABILITY THE ISSUANCE OF A PERMIT The City of Tigard and its BASED ON CONSTRUCTION DOCUMENTS AND OTHER permits@auricsolar.com employees shall not be il DATA SHALL NOT PREVENT responsible for discrepancies DATE: 1111,2019 THE CODE OFFICIAL FROM which mayappear herein JOB NO: 178138 THE CORRECTION pp REVISION N0: 001 OF ERRORS.ORSC 105.4 DESIGN BY: <o 1 °F 7 r 1 >- INDEX `•/ NOTES: a I' Sheet Number Sheet Title y,,, 1 TITLE 1. ATTACHMENT FEET WILL BE FIELD ADJUSTED TO ACCOMMODATE TRUSS POSITIONS. `�'� 2. 4 FT. MAXIMUM SPACING BETWEEN ATTACHMENT POINTS, AS PER OREGON STRUCTURAL „ter/ di 2 INDEX-LEGEND-MECHANICAL DETAILS&NOTES SPECIALTY CODE, 3111.5.3. 3 PLAN LAYOUT 3. RAIL END OVERHANG LIMITED TO LESS THAN 34% OF MAXIMUM SPAN (18 IN MAXIMUM). _,_ 4. SEE ATTACHED SHEETS FOR SNAP N RACK ULTRA RAIL-40 WITH STAGGERED FLASHED 4 STRING LAYOUT&ELECTRICAL INTEGRATION ULTRA RAIL COMPOSITION L-FOOT BASE DETAILS. 5 SINGLE LINE INTERCONNECTION DIAGRAM&LABELING 5. IF ARRAY IS CLOSER THAN 3' FROM ANY RIDGE, HIP OR EDGE, ATTACHMENT POINTS ! "S"°,Z,,, MUST BE 24" O.C. MAX. AS PER OSSC 3111.5.3(1)&(2). T )� 6 ELECTRICAL CALCULATIONS,NOTES&DETAILS 6. PV MODULES MUST NOT BE INSTALLED OVER OR BLOCK ANY ATTIC VENTS, PLUMBING 6 7 BILL OF MATERIALS VENTS, FURNACE OR WATER VENTS, ETC. 7. ARRAY WIRE MANAGEMENT SHALL BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL .- ** 'ELECTRICAL&MECHANICAL EQUIPMENT CUT SHEETS MEANS DESIGNED AND LISTED FOR SUCH USE AND HELD OFF THE ROOF SURFACE. 8. EGC's SHALL BE RUN WITH ASSOCIATED CIRCUIT CONDUCTORS IN ACCORDANCE WITH NEC "SEE ATTACHED CUTSHEETS FOR EQUIPMENT MANUFACTURER SPECIFICATIONS. 690.43(C) 9. INSTALLER TO VERIFY PROPER GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH NEC 250.50. 10. ALL INSTALLATIONS SHALL COMPLY WITH OSSC REGULATIONS, 2015 IBC & 2017 NEC. 11. RAIL MIDCLAMPS CAN ONLY BE POSITIONED ±3" OF MOUNTING HOLE. 12. STAINLESS STEEL ATTACHMENTS REQUIRED TO MITIGATE CORROSION. N- o 0 0 a) if,4)a cc v u DETAIL A DETAIL B0 D FLRNEo L-FOOT EL@m 1-FOOT 0 w 1:10,Q cC I—FLASHING FLASHED ULTRA RAIL FLASHING 0 0 ,.i, COMPOSITION L-FOOT FLASHED ULTRA RAIL w I- c4 c9 COMPOSITION L-FOOT L cn S (SEE NOTE 4) w w Q co 0 CC I- <- tr W �3 ( 18 ac e` 4 cc C.3 J -'m 4�0� 0 U oa =1 LI_ z 0 Q Gy FOR ROOF p 170 U o ANGLE SEE �� N rn b 1'-6" MAX. SHT. 3 LU X .u)o, SNAPNRACK (SEE NOTE 3) w -8,75 ULTRA RAIL 40 H �`o D — 'o o . 2 () o`vim° DETAIL C DETAIL D DETAIL E v 0-Ti SNAPNRACK Y2" 3'-IW3'-5>¢" 2» v�sE.we oRQlrnlaH 5'_�js" y" BONDING DEM » Co 2 PORTROT OPEJTON ---1- [ FLASHED ULTRA RAIL y � co COMPOSITION "L" FOOT °�+ SNAPNRACK ULTRA RAIL-40 (SEE DETAIL A) � SNAPNRACK RACKING SYSTEM IA_IA=MrME ,"�..',, ULTRA RAIL 40 ' I��� SNAPNRACK •N b w RACKING SYSTEM (SEE NOTE 4) !I_ n ULTRA RAIL 40 - A�m` (SEE NOTE 4) ffl �' ■■RACKING SYSTEM r �- �r1 ' •.r 1 ---Pi � SOLADECK — I Iwww- _, _. V' (SEE NOTE 4) 1'-6" MAX TO FIRST FOOT ��� SNAPNRACK EQUIPMENT ��-- DATE: U2019 1' 6" MAX dl■■ TO FIRST FOOT A A A ��I STAGGER ATTACHMENT FLASHED ULTRA RAIL GROUNDING JOB N4 178138 POINTS BETWEEN ROWS COMPOSITION "L" FOOT CONDUCTOR. 6 �i11 (SEE DETAIL A) COG BARE REVISIONESIGNNO: (3 01 4'-D"TIP. COPPER WIRE �'-- SEE NOTES 4'-0" oesi�N av: o STAGGER ATTACHMENT 1 & 2 SEE&OZES SNAPNRACK GROUND LUG 1 POINTS BETWEEN ROWS (1 PER ROW REQUIRED) 2 °F 7 + ARRAY SQUARE FOOTAGE WES: TOTAL ROOF AREA TOTAL ARRAY AREA TOTAL ARRAY COVERAGE 1. FIELD ADJbST ARRAYS ON SLOPE FOR BEST 1952 426.65 21.86% CI 2. ALLOW 1' FROM RIDGE AS PER OREGON 16842 SOUTHWEST BIRDSONG STREET """ ` PRE CODE. C ! 3. STAGGERED ATTACHMENTS REQUIRED. SEE PAGE 2 DETAILS C & D. ada zia 4. TRUSS SPACING IS 24" O.C. (TYPICAL). ° 4 v v W IC 6 w a a _ d. 2 °_D v 4 A ° o ° t a d ° a d d d v ° I O INDOOR LOAD CENTER & 4 d a ° v POINT OF INTERCONNECTION I o 4 ° a 4 I 1 ' / / / / / / / .' / / / 7 , / / / / / / / / / ' / / ti 0 UTILITY METER ,_..--<.,.....,.....--------------..-----.- - I 0 0 I 0) v a u PV UTILITY DISCONNECT / U U�, _ARRAY Y 1 - O0 CO N 23 MODULES -0 0 PV AC COMBINER BOX / 0 0 N 00- I / U U I 0 U 7 N I ❑/ ❑ N w I— al 09 U U Z / H— >n U U Q cc : < F- O d 3 I Q I w N } Qo N og 0. • ❑ /❑ u u I � O Z 0°0 i Z C/) Q 0 ATTIC ACCESS J cC 0. a,_ 0 /❑ o °° ° U U I CC I— o 0 U U U m ❑ / / I w II° / / U U U = ❑ 1 F v a.a 7 co co 22 I //.//// //7// //// // //// /,// //// ////,/� // I co ROOF DESCRIPTION I I ARRAY ROOF TILT ROOF AZIMUTH TSRF 3'-O= #1 27 90' 81% FENCE ASPHALT SHINGLE ROOF I I PANASONIC VBHN325KA03 325W I DATE: 10/2019 MODULES JOB NO: 178138 ENPHASE IQ7X-96-2-US REVISION N0: 001 MICROINVERTERS - - - - - - - - - - - - DESIGN BY: I/O 23 © 325W = 7.475KW SCALE 3 7 SEE ATTACHED SHEET FOR DETAILS a ti • D ARRAY 1-23 MODULES 1. CIRCUIT 1 CIRCUIT 2 SEE SHEET 5 SEE SHEET 5 "+, OIT 00 O0 0 \, ` 0. 1 Id =f1 � _ft19 _ftp 't p. 72. K. Cl C1 rai C1 C1 C1 C1 C1 C1 C1 =CC4 Up Oi PC C— C2 C2 iC2 C2 C2 C2 C2 C2 • Cl o 9 i CD .Sli .E V-. 1= I- roE Lu . c U H V) w w a C fa CI CC U a— - E- ITV 0 C S U a Lu c VI_SI C2 C2 O J J cc � <. J 15 o © cc i_ O c. W J �, -8,,`° ic I 3 '-11" m--O- D o D ( c 0 I— vo (1) U) a o N Ou_ NOTES: v a°- co P cc 1. MODULES ARE BONDED TO RAILS USING SNAP N RACK BONDING MID CLAMPS. SEE CUT SHEETS FOR LEGEND DETAILS. A ENPHASE 2. ARRAY IS TO BE BONDED TO THE CIRCUIT EGC AT MICROINVERTERS A SINGLE POINT PER ROW WITH A LISTED BONDING LUG USING BARE 6 AWG COPPER. AS PER NEC B Q SOLADECK 690.43. 3. SEE CUT SHEETS FOR ENPHASE INVERTER CABLING C ® CABLE CONNECTOR ACCESSORIES SPECIFICATIONS AND DETAILS. DATE: 139/2019 D O BRANCH TERMINATIONS 4. SEE CUT SHEETS FOR COMBINER/ENCLOSURE JOB NO: 178139 SPECIFICATIONS. REVISION NO: 001 JUNCTION BOX R 5. SINGLE MODULES REQUIRE ALL METAL PARTS AND DESIGN EY: KD E MODULE FRAMES, TO BE BONDED TO #6AWG EGC, SCALE pp SCALEUTILIZING A LISTED BONDING LUG. 4 °` 7 NOTES: t LOAD SIDE INTERCONNECTION 1. 120/240V, 4 METER SOCKET ONLY LOACTED WEST SIDE OF THE HOUSE. (EXISTING) 705.12(B)(2)(3)(b) ■ =Som. a moo2. 225A RATED, 120/240V, 4 INDOOR LOAD CENTER, SQ-D HOMELINE, LOCATED ON WEST WALL 00 ©O INSIDE GARAGE. (EXISTING) D LL; 3. 60A RATED NON-FUSED PV UTILITY DISCONNECT, TO BE INSTALLED WITH 10' OF UTILITY METER ON WEST SIDE OF THE HOUSE. (NEW) O© 4. 125A RATED ENPHASE 10 AC COMBINER 3 BOX. (NEW) 5. SOLARDECK PV ROOF-MOUNT PASSTHROUGH ENCLOSURE. AC/DC-SD-786-3R. 7 7 , 6. PANASONIC VBHN325KA03 325W MODULES, ENPHASE IQ7X-96-2-US MICRO-INVERTERS WITH 1.0 I POWER FACTOR AT RATED POWER AS PER MANUFACTURER, ENPHASE Q CABLE. EXISTING 200A/2P ,. 7. LOAD SIDE WITH 40A/2P BREAKER AT THE BOTTOM OF THE BUS. UTILITY —00•• SERVICE EXISTING WIRE 1 OCPD ')40A/2P (,„ ,1 L _1 ' NEW SOLAR (2)6WG (1)6WG NEUTRAL EXISTING LOADS (1)TOWG EGC O 3/4 CONDUIT MIN. N- LABELING: rn Z o 0 2017 NEC CODES,NTBCU:w0 ©OOO 0 I� D'2- UTILITY TO BE INSTALLED AT THE , p m 2 N UT MY/METER O II CC CO O 0 NEC 7oi.to / PARALLEL ON-SITE O / I � "ID u SOLAR GENERATION A // LU --1 TO BEDS INSTALLED ON MAIN SERVICE DISCONNECT F Z LLI Q TO LABEL MUST BE PRINTED IN COLOR AND FONT HEIGHT (2)6WG W LLI Q9 AS DEFINED IN NEC 690.S6(C)(1,31 (1)10WGNEGC�L O Cl CC 3 SOLAR RV SYSTEM EQUIPPED WITH RAPID SHUTDOWN 3/4'CONDUIT MIN. W 01 cC 0 O N Z U o.N u o p w o R.•,Rowx.. 1. •)20A/2PZ U A P -o ' t0A 2P20 2 / / Z Z cc_c oo� "TME>"•>T p OCPD NEW SOLAR NEW SOLAR J cc 0 Q� —1 — (_) "5= o CD 0 � o- TOBEwsTADEoaNPvascoNNECT ENPHASE ENVOYro NEC 690.1318) CC N I- 01t PHOTOVOLTAIC AC DISCONNECT 12/2 OF-B 12/2 OF-B LU Z q,T MAX.AC OPERATING CURRENT:30.13A OC (3/4"CONDUIT O (3/4'CONDUIT O Lu -o c MAX.AC OPERATING VOLTAGE:240 V WHERE NEEDED) WHERE NEEDED) 2 Z �.- D —1 -C TORE INSTALLED ON RAPID SHUTDOWN DEVICE p W NEC 690 5E171{3) O O (� QN N (!3 'Ou RAPID SHUTDOWN SWITCH O DC_ fi FOR SOLAR PV SYSTEM CO ENPHASE ENPHASE ENPHASE ENPHASE TO BE INSTALLED NEXT TO BACK-FED BREAKER 0 CABLE Q CABLE 0 CABLE Q CABLE NEC 7051E191(2330) /—SEE SHEET 4 pr SEE SHEET 4 T SEE SHEET 4 r SEE SHEET 4 OWARNING POWER SOURCE OUTPUT CONNECTION O DO NOT RELOCATE K In v, cn THIS OVERCURRENT DEVICE i71 P 'P"1Pijl L�Pil TO BE INSTALLED CN PV DISCONNECT, .S .—5 --S -S CONDUIT EVERY IO'AND UTILITY SERVICE ? Z Z Z NEC 690 31(G)(3)&690 31(B) U VW I SI�II U w U N I�I C=J 1S-2 .-1 C J • OWARNING O o v o oc7o DATE: 1n2019 PHOTOVOLTAIC POWER SOURCE M M M M TO BE INSTALLED AT MAIN SERVICE DISCONNECT v-, co 40 Rt JOB NO: 178138 REVISION NO: 001 RAPID SHUTDOWN SWITCH DESIGN BY: KD LOCATED OUTSIDE ON O WEST SIDE OF HOUSE O O O O 5 of 7 VOLTAGE46ROP CALCULATIONS t >- • FROM TO VOLTAGE PHASE CONDUCTOR#INVERTERS FLA(I)WIRE SIZE LENGTH CIRCULAR MILS(CM)CU/ALCONSTANT(K)VOLTAGE DROP TOTAL VOLTAGE DROP VOLTAGE DROP%TOTAL VOLTAGE DROP% r INIMMINI L') WORST CIRCUIT(1)(CIRCUIT 1) SOLADECK/JUNCTIONR BOX(1) 240 1 CU 6 7.86_ 12 (1) (1) (1) 0.47 0.47 0.20% 0.20% !OIADECK/JUNCTIONRBOX(1) PV AC COMBINER PANEL 240 1 CU 11 14.41 12 55 6530 12.9 3.13 3.60 1.30% 1.50% Luso L,'_ PV AC COMBINER PANEL PVUTIUTY DISCONNECT 240 1 CU 23 30.13 6 10 26251 12.9 0.30 3.90 0.12% 1.62% PVUTIUTY DISCONNECT POINT OF INTERCONNECTION 240 1 1 CU 23 30.13 6 10 26251 12.9 0.30 4.19 0.12% 1.75% D 1.1.1 FROM TO VOLTAGE PHASE CONDUCTOR#INVERTERS FLA(I)WIRE SIZE LENGTH CIRCULAR MILS(CM)ICU/AL CONSTANT(K)VOLTAGE DROP TOTAL VOLTAGE DROPVOLTAGE DROP%TOTAL VOLTAGE DROP% Z WORST CIRCUIT(1)(CIRCUIT2) SOLADECK/JUNCTION R BOX(1) 240 1 CU 8 10.48 12 (1) (1) (1) 0.80 0.80 0.33% 0.33% il SOLADECK/JUNCTI ON 9 80X(1) PV AC COMBINER PANEL 240 1 CU 12 15.72 12 55 6530 12.9 3.42 4.22 1.42% 1.76% c PVACCOMBINER PANEL PV UTILITY DISCONNECT 240 1 Cu 23 30.13 6 10 26251 12.9 0.30 4.51 0.12% 1.88% 00 PVUTIUTY DISCONNECT POINT OF INTERCONNECTION 240 1 CU 23 30.13 6 10 26251 12.9 0.30 4.81 0.12% 2.00% mss,, (1) SEE ENPHASE Q GABLE VOLTAGE RISE TABLE IN CUTSHEET PACKAGE $ GENFRALIQT_ES: ATTACHMENT POINT DETAIL w �s ,, � 1. IF REQUIRED,AS PER NEC 705.12(B)(2)(3)(b), LOAD SIDE r INTERCONNECTED BREAKERS TO BE INSTALLED AT OPPOSITE END OF BUSBAR FROM INPUT FEEDER. 2. ALL CONDUCTORS SHALL BE 90' C THWN-2 COPPER UNLESS OTHERWISE NOTED. 3. IN OREGON, ANY SYSTEM OVER 7.2kW DC INVERTER OUTPUT REQUIRES A DISCONNECT THAT IS MANUAL, LOCKABLE, LOAD BREAK, HAVE A VISIBLE BREAK, AND BE LOCATED WITHIN 10 FEET OF THE UTILITY METER. IF LOCATED ELSEWHERE,AN APPROVED DIRECTORY DENOTING IT'S LOCATION MUST BE INSTALLED AT THE UTILITY METER. N- 4. THE SIGN MUST BE REFLECTIVE, WITH ALL LETTERS CAPITALIZED, AND p c LETTERS ARE AT LEAST 3/8"IN HEIGHT, WORDING MUST ALSO BE WHITE ti `o ON A RED BACKGROUND. CC J N u 5. VERIFY PROPER GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH '°N' NEC 250.50. ❑ -II--_ 0 o 6. ANY WHITE NEUTRAL CONDUCTOR USED AS A PHASE CONDUCTOR SHALL --'---•- -• Ci o N o BE RE-IDENTIFIED USING RED TAPE AT ITS TERMINATION POINTS. TAPE _- • - (a7 oZ) Y SHALL BE APPLIED IN ANY LOCATION WHERE CONDUCTOR IS VISIBLE AND _ i= (7,.v, ACCESSIBLE IN ACCORDANCE WITH NEC 200.7(C)(1). : V H . g 7. ALL ELECTRICAL EQUIPMENT SHALL COMPLY WITH THE WORKING o o z w 0 >. CLEARANCE REQUIREMENTS DEFINED IN NEC 110.26. - --.- Lt.( So 8. ELECTRICAL EQUIPMENT, CONDUCTORS AND RACEWAYS SHALL BE PERMITTED _-,.� Q Ln a- TO BE INSTALLED DIFFERENTLY AS SPECIFIED ON ELECTRICAL DIAGRAM IF w Z CC 5 INSTALLATION MEETS NEC CODE AND MANUFACTURER REQUIREMENTS. cc C7 I., O, 9. ALL RACEWAY MINIMUM SIZE CALCULATED FROM NEC CHAPTER 9 TABLE 4. ❑ ❑ -o-�-- -- zLD 0 a �� -- - Z n irL 0 --rte J - J J Q O ❑ -L7---.- -.- -.---- O Lb a o- H- U cCD 0 ---•- (f) -I 0,o LEGEND a --�--= -= �--- -- -- ---o I I- '-o O\ DL) v 0 O c J - CIRCUIT BREAKER ❑ _II . 0 ° - N w o O V aaa o ®I - UTILITY DISCONNECT op / 2X4 © 24"O.C. - FIRE FIGHTER ACCESS TYPICAL / / SNAPNRACK UR-40 RAILS (TYPICAL) (TYPICAL) OM - UTILITY METER ATTACHMENT POINTS (48) SPACED®48"O.C. LIE OM - PRODUCTION METER SEE SHEET 2, DETAILS A-D DATE: 11/1/2019 15'D JOB NO: 178138 REVISION NO: 001 I - GROUND SYMBOL DESIGN BY: KO 6 7 BILL OF MATERIALS , _... ��. r QTY ITEM # DESCRIPTION DESIGN REMARKS FIELD REMARKSStow 23 VBHN325KA03 PANASONIC 325W MODULES 23 107X-96-2-US ENPHASE IQ7X MICROINVERTERZ x LU 23 242-92093 SNAP N RACK MLPE RAIL ATTACHMENT KIT SOLADECK PV ROOF-MOUNT PASSTHROUGH ENCLOSURE, 1 053-00225 a" AC/DC-SD-786-3R „,'—' 48 242-01220 ULTRA RAIL UMBRELLA L-FOOT, BLACK 4 48 242-92266 UMBRELLA LAG, 4" d . 48 232-01375 COMP. FLASHING 9"X 12 , BLACK ALUM (REQUIRES UMBRELLA LAG) 27 052-10112 ENPHASE 0 CABLES 240 (PORTRAIT); PER CONNECTOR 0 052-10113 ENPHASE Q CABLES 240 (LANDSCAPE); PER CONNECTOR 4 300-07706 ENPHASE 0 WATER TIGHT CAP 4 300-07707 ENPHASE Q BRANCH TERMINATOR 12 232-02451 SNAP N RACK ULTRA RAIL, 168-, BLACK OO 0 O U 8 242-01214 ULTRA RAIL SPLICE, BLACK a,,a cc s' 40 242-02054 SNAP N RACK BONDING MID CLAMP, 33-45mm (1.30-1.77"), BLACK 0 0 a • N 12 232-02452 SNAP N RACK ULTRA RAIL END CAP a L o 0U � 12 242-02215 SNAP N RACK UNIVERSAL END CLAMP w v r (1 3 242-02101 SNAP N RACK GROUND LUG R - 6-12 AWG 0 LU < a 1 HITCH CLIPS w w <c <n � SEE SHT 5 LABELS v) z0 o Y 1 X-1Q-AM1-240-3 ENPHASE IQ COMBINER 3, W/ENPHASE IQ ENVOY D, 0 OJ .c t J cc J Q 0 2 BR220 EATON 20A/2P BREAKER C F m c m ( 01`o 1 HOM240 SQ D HOMELINE 40A/2P BREAKER D c E- �o 11 60A RATED NON-FUSED OUTDOOR KNIFE SWTICH v o 060 a NU V a'a co 5 ,III a) DATE: 11/1/2019 JOB NO: 178138 REVISION NO: 001 DESIGN BY: KD 7 of 7 ..-, . ,..,-..,... ___ .. itc!,,, ,.., , 1 ..1,__ .,•, :iii • ii ii ni ei . - 4,I,IPTittillui I gm ii -NI 11 ..it _ re'-_..,•-- HOMELIPNIE ' LOAO CENT, •:-:-. P,3iteibodrii tnterrot-for Catatoq No. .. Box i t.-..:ata ..-.1,-'- ---- — ----- • ' , ..-• , .,. _.. .. . . . , ..... .. ...„ ,_ 4, )VP(/( fib /fa ii--''MIMBIN .411111E ;tigt--•",* . .• . : . . • . „. ,-,•.• •,...„: Q ,L-i,-)A.4(2301/c '''.'---- --At.--- Attain!) rttax. 1 - , 5''' 200A , .t-Itis Bar Fiating 1 Capactdad de 'Ir.i s . , , • • tiarra de conexton ... - - --..„;, , z--- - 225A m 1 ax, '-",:‘ 1--",,:: ..,....-_-t .1 , . -. i -- •,,,,,,_,,T,-„,..„,...***,.., . ,,,.„... - - '4,1 -----.-,:.-,-,F:t'f-----.-s .--- --*--7,--:::.it:r.- -,;0-4--...--- -...:- •.--•.-----,,....r•- • -, e 'nam or SerVice discorinect :..- .,------ 240 V--Max., 10; 50/804& circuit aximair. circuitils:p rit 60 ------ .4-''.;.il';-::4:40i,!i,..!::!!!'.--- Type i Ervcipstoro,i G-- -:!: i,. ..„:1_,,,,;.‘:,._!:_::::....,,_.,-.E--:.--'''.--'±.--_,----'-•*.' . '''' ''----"'''''-''''--- "--, - •-:---,-1,-.'---, -,-c,-------;;;..-.,.,-_,''.,;,4--..,:._- _--..4;4::....;i-:.4r(---- - - . - -..-r ,,..-..-.;,,-.'•f.,,-,_;.:-_. ti - I - , - - -- • 1-1., ' . '• I!;lii! :-::,,,,,,,'•,10. ..1;ii .;',.%_., .iiall,...7-c.ti,.,.. -!:j,,,,,-, -;,:t-,1--.-1-N,t..*11.,,,,,-*: -..„ ' ,,.,.,_ .7.-_•,'''k-k...,-., '-,.% -4, -Ii-,,- '''' --:,2L -'',7--' .-- -..,-,..V 7 „ -.." -- _ . „..- :. •, . ,,,,___. ....- ;--iii,,,O,'-..k. --1-1f.4i;ztir:7-'::-„t!,..-, —. , _„.. .. ,,,.,....„.. .... - ' 3ir'k-S'',,, ' j•kt. ' '''' ''' ....„. ,.. . . .... .. .. ._ .„ .... . ..„...„„ , . ...,.. ......,...____.. - I ` .0*i-,-.., ----.. . --''''''-•-.1 . , _.. , ,,. ..........._s_._ ...:--.. : ' . --- ....._.,..._ .,- . '' - -' 4 --_,• - 1114 11.F...`.. '''''"-''''''' . 4 • - -77":,_-_-..__""--:'_ --_._-_.--_---..-.---_,..„___,,,„.;,_., „-...--- - ______..... - -- ... , , ,.,..... '., . .1e.. 4. '