Loading...
Permit (2) 114 CITY OF TIGARD MASTER PERMIT ■. ' COMMUNITY DEVELOPMENT Permit#: MST2019-00414 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 11/18/2019 T f C;A R,D 9 Parcel: 2S 104AC 13100 Jurisdiction: Tigard Site address: 12810 SW 135TH AVE Subdivision: 1997-031 PARTITION PLAT Lot: 2 Project: SADLER Project Description: Solar photovoltaic system. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $3,500.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add l 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: Y Other Description: Roof top PV system 12.09 kW Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: SADLER,JAMES&PAULA GREENLIGHT SOLAR Required Items and Reports(Conditions) 12810 SW 135TH AVE 6115 EAST 18TH STREET SUITE B TIGARD,OR 97223 VANCOUVER,WA 98661 PHONE: 503-332-5376 PHONE: 360-836-8902 FAX: Total Fees: $358.19 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you `o follow tt•' rul-s adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OA' '-001-0090. You m. obtain;✓•py e.e rules or direct questions to OUNC by calling 5 3.232.1987 or 1.800.332.2344. Issued By: i . . KAM ISL Permittee Signature: --� 12:: "�—te > / — Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. r Approved plans are required on the job site at the time of each inspection. Building Permit Application residential FOR OFFICE USE ONLY City of Tigard (j ( 2.019 DateBy 1 D , i i" 4S 0 5- �Z 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review Phone: 503.718.2439 Fax: 503 598 1960 l Date/By: 0 j Q !4 Other Permit: TIGARD Inspection Line: 503.639.4175 ,,r ,; ' ;.,;_, ti ' � ^�''N Date Ready/By: 1 / 1wi% See Pae 2 for w Internet: ww.tigard-or.gov ed/ eth •- (� I H Supplemental Information i6 t TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING A 0 New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the -t work indicated on this application. fr.,. ' {,ro, CATEGORY OF CONSTRUCTION <, a ® 1-and 2-family dwelling 0 Commercial/industrial Valuation: $3500.00 ❑Accessory building 0 Multi-family Number of bedrooms: 4 ❑Master builder 0 Other: Number of bathrooms: 3 JOB SITE INFORMATION AND LOCATION Total number of floors: 2 Job site address:12810 SW 135th Ave New dwelling area: square feet City/State/ZIP:Tigard,OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:OR179 Sadler Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: 1 Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Installing a 12.09kW PV System(39-Silfab SLA310M&20-APS YC600) Valuation: $ Existing building area: square feet New building area: square feet ® PROPERTY OWNER 0 TENANT Number of stories: Name:Jim&PAula Sadler Type of construction: Address:12810 SW 135th Ave Occupancy groups: City/State/ZIP:Tigard,OR 97223 Existing: Phone:(503)332-5376 Fax:( ) New: 0 APPLICANT 0 CONTACT PERSON BUILDING PERMIT FEES* (Please refer to fee schedule) Business name:GreenLight Solar Structural plan review fee(or deposit): Contact name:Angie Olesen FLS plan review fee(if applicable): Address:6115 E 18'Street Ste.B Total fees due upon application: City/State/ZIP:Vancouver,WA 98661 Amount received: Phone:(360)836-8902 Fax::(360)258-0092 E-mail:angle@greenlight-solar.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted Photo Voltaic Solar Panel System. Business name:GreenLight Solar Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:6115 E 180i St.Ste.B Solar Installation Specialty Code checklist. City/State/ZIP:Vancouver,WA 98661 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(360)836-8902 Fax:(360)258-0092 State surcharge(12%of permit fee): $21.60 CCB lic.:211333 Total fee due upon application: $201.60 Authorized signature: ( This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name:Angie Olesen Date:10/15/19 *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Electrical Permit Application FOR OFFICE USE ONLY of City Tigard Date/By: - RPermit#: '� 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Related Permit#: T I GARD Inspection Line: 503.639.4175 Ready Date/By: Juris: I Ed See Page 2 for ce Internet: www.tigard-or.gov Notified/Method: Supplemental Information TYPE OF WORK PLAN REVIEW ❑New construction /1 Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): ❑Service or feeder 400 amps or more 0 Building over three stories. ❑Demolition ❑Other: where the available fault current 0 Marinas and boatyards. exceeds 10,000 amps at 150 volts or 0 Floatingbuildings. CATEGORY OF CONSTRUCTION ® 1-and 2-family dwelling 1:1Commercial/industrial ❑Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural amps for all other installations. buildings. 0 Multi-family ❑Master builder ❑ Other: ❑Fire pump. 0 Installation of 150 KVA or :4,: JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived ❑Addition of new motor load of system. Job#:OR179 Job site address: 12810 SW 135th Ave 100HP or more. ❑"A">"E">"1-2">"1-3"> ❑Six or more residential units. occupancy. City/State/ZIP:Tigard,OR 97223 0 Health-care facilities. 0 Recreational vehicle parks. Suite/bldg./apt.#: Project name:OR179 Sadler 0 Hazardous locations. 0 Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site:SW Walnut St&SW 135th Ave FEE SCHEDULE Description I Qty. I Each I Total I New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#: Ea.add'l 500 sq.ft.or portion 33.92 l DESCRIPTION OF WORK Limited energy,residential above sq.ft.) 75.00 2 (with Installing a 12.09kW pV System(39-SLA310M&20--YC600) Limited energy,multi-family 75.00 2 residential(with above sq.ft.) Renewable Energy 0 See Page 2 0 PROPERTY OWNER ❑ TENANT Services or feeders installation,alteration,and/or relocation Name:Jim&Paula Sadler 200 amps or less 100.70 2 Address:12810 SW 135th Ave 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP:Tigard,OR 97223 601 amps to 1,000 amps 301.04 2 Phone:(503)1332-5376 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 I intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 0 APPLICANT 0 CONTACT PERSON Branch circuits—new,alteration,or extension,per panel A.Fee for branch circuits with Business name:GreenLight Solar above service or feeder fee, 7.42 2 each branch circuit Contact name:Angie Olesen B.Fee for branch circuits without service or feeder fee,first Address:6115 E 18th Street Ste.B 56.18 2 branch circuit City/State/ZIP:Vancouver,WA 98661 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:(360)836-8902 Fax: :(360)258-0092 Each manufactured or modular 67.84 2 dwelling,service and/or feeder Email:angie@greenlight-solar.com Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name:Greenlight Solar Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy Address:6115 E 18th Street Ste.B panel,alteration,or extension. 0 See Page 2 2 City/State/ZIP:Vancouver,WA 98661 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:(360)836-8902 Fax:(360)258-0092 Investigation(1 hr min) 90.00/hr Email:angie@greenlight-solar.com Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is 90.00/hr CCB Lic.: 211333 Electrical Lic.: C-1430 Suprv.Lie.: 5787S specifically listed(Yz hr min) ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: Cjitx4641. ), A Subtotal: • Print name: Charles Bitton Date: 10/15/19 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): TOTAL PERMIT FEE: Authorized signature:l/��y`,: _ s. 411.4"____ This permit application expires if a permit is not obtained within 180 Print name: Angie Olesen Date: 10/15/19 days after it has been accepted as complete. * Number of inspections allowed per permit. I:\BuildingWermits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(11/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE Fee for all residential systems combined: $75.00 Description Qty. I Each I Total 3' Renewable electrical energy systems: Check Type of Work Involved: s kva or less 100.70 2 5.01 to 15 kva 1 133.56 133.56 2 n A• udio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 Ti Garage Door Opener* >100 kva(fee in accordance 552.26 2 with OAR 918-309-0040) Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ri V• acuum Systems* >100 kva-no additional charge 0.0 3 Each additional inspection over allowable in any of the above: Ti Other: Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed(%hr min) COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES Fee for each commercial system: $75.00 Subtotal(Enter on Page 1): y * Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: E Audio and Stereo Systems Ti Boiler Controls Ti C• lock Systems ❑ Data Telecommunication Installation 7 Fire Alarm Installation ❑ HVAC Ti Instrumentation Intercom and Paging Systems Ti Landscape Irrigation Control* [ Medical Ti Nurse Calls E Outdoor Landscape Lighting* ✓ Protective Signaling Other: Total number of commercial systems: _ *No licenses are required. Licenses are required for all other installations L\Buitding\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 r I 4.<47% Oregon Solar Installation Specialty Code �° Checklist for Prescriptive Photovoltaic Installations in accordance with Section 3111.5.3 Department of Consumer and Business Services Building Codes Division 1535 Edgewater NW,Salem,Oregon Mailing address:P.O.Box 14470,Salem,OR 97309-0404 Phone:503-378-4133 •Fax:503-378-2322 Web:bcd.oregon.gov PROPERTY OWNER INFORMATION Property owner name: J\m 3 0.vack. 3.,c1\e1' Installation address: 12?AD S\.) 1755t1 Pkv e— City7T9krA State: OR ZIP: GI--i aa3 Structure on which modules are to be installed: x-Doc- Day phone: (5pS)?j3 Z..53.7 k.P I Evening phone: (-- ) --- Email address:3pc\\ef-&cktA.cot-v.-, Contractor: (-art en ` h,}- S O la y CCB#: 211 3 33 Day phone: (13k16 B' (c.e6q,O a Evening phone: (— ) -- Email address: OS t C@ ,r�Q, y - _s6�r, (err\ ��JJ SITE PLAN • Attach a simple site plan showing the location of the PV system in relation to buildings, structures,property lines,and,as applicable,flood hazard areas. • System must be shown in sufficient detail to assess whether the requirements of Section 3111.4.8 or one of the exceptions have been met. • The site plan must be on 8.5-inch x 11-inch or larger paper. STRUCTURAL INFORMATION All structures: • Is this conventional light framed wood construction? Yes S. No ❑ (check one) • Does the structure have pre-engineered trusses? Yes ❑ No (check one) OR • Does structure have roof framing members spaced at 24 inches on center maximum? Yes jg No❑(check one) • Is the weight of the PV modules and racking less than 4.5 pounds per square foot? Yes, No ❑ (check one) • Is the roofing material metal,single layer wood shingle,or not more than two layers of composition shingle? Yes 71 No ❑ (check one) ir,DEPARt ENT f C�OBNgI�JMER !�-.IxSERViCES 4404910(9/15/COM) Y � STRUCTURAL INFORMATION (continued) Standing seam metal roofs: • Is the metal gauge 26 or heavier? Yes ❑ No ❑(check one) • Clamp design:Are clamps designed to withstand uplift of at least 115 pounds for clamps spaced at 60 inches on center or less or at least 75 pounds for clamps spaced at 48 inches on center or less? Yes ❑ No ❑(check one) • Is the spacing of the clamps as measured along the seam less than or equal to 24 inches on center? Yes ❑ No❑ (check one) • Is the roofing panel width 18 inches or less? Yes ❑ No ❑ (check one) • Will the roofing panel attachments be at least#10 screws at 24 inches on center? Yes❑ No❑ (check one) • Will the roofing panels be installed over minimum V2-inch nominal wood structural panels attached to framing with 8d nails at six inches on center at panel edges and 12 inches on center field nailing? Yes ❑ No ❑ (check one) If no, on any of these requirements, the project may not be submitted using the prescriptive path. ROOF DESIGN AND ATTACHMENT • Attach a simple structural plan showing the roof framing(rafter size,type,and spacing)and PV system racking attachment. • System must be shown in sufficient detail to assess whether the requirements of Section 3111.5.3 have been met. • The structural plan must be on 8.5-inch x 11-inch or larger paper. WIND DESIGN • Does the project site exceed 95 mph in exposure C or 105 mph in exposures A or B? Yes ❑ No f(check one) Ifyes, the project may not be submitted using the prescriptive path. • Is the module height less than 18 inches above the roof in accordance with section 3111.5.3? Yes gi No ❑ (check one) PV MODULES Manufacturer: Q).\W-0,\13 Model number: \,A \\N Listing agency: �) �\-1 Ap ant name(please print) pplicant gignatur Date 440-4910(9/15/COM)