Loading...
Plans (2) PROJECT SUMMARY PROJECT DIRECTORY VICINITY MAP ...Mf'. 3JLT VI >vV r PROJECT ADDRESS 11555 SW DURHAM ROAD I TIGARD,OR 197224 OWNER ARCHITECT I ARCHITECTURE, LLC LEGAL DESCRIPTION R2081779- 1998-128 PARTITION PLAT LOT:1 HARSCH INVESTMENT PROPERTIES MELYNDA RETALLACK i stu^f YEAR BUILT 1951 INK:BUILT ARCHITECTURE a, PROJECT SITE 2808 NE MLK ste G 1620 SW TAYLOR ST, STE 300 2808 NE MLK BLVD, STE G �ecfge ,� wood Di PORTLAND, OR 97212 SITE AREA 4.67 ACRES 5 CA' T ,, >-'9 503.454.6793 PORTLAND, OR 97205 PORTLAND OR 97212 ,E..r`� °j °j inkbuiltdesign.com ZONING C-G +503.242.2900 +1.503.701.5277 kimtrrrerfeei7 ``pit Z :, Golf Course CONSTRUCTION TYPE IIIB FULLY FIRE SPRINKLERED GENERAL CONTRACTOR �+D Al�e� OCCUPANCY B(D6) PACIFIC CREST STRUCTURES INC. Y SW DURHAM ROAD /1(::::1):-Dr::::11/' SAD. rafts FLOORS/HEIGHT 1 STORY CCB#66915 9 r ,/;�. C17750 SW UPPER BOONES FERRY RD., #190 '.AREA OF WORK 2,148 SF(D6) - DURHAM, OR 97224 E v �av' � jtro !Y� !+1.503.968.8949 t City �, ' 5 '' 4GatrS' � o "SW Titan L - ^�SCOPE OFWORK DESCRIPTION• -4fsl, t;, - R�t�rh SW Kent StOL• 0DEMO WORK TO REMOVE WALLS AND PLUMBING FIXTURES.(E)ADA RESTROOMS - IAND BREAK ROOMS TO REMAIN. MODIFY EXISTINGRESTROOMSINB2. APPLICABLE CODES + REGULATIONS s `'` p_NOTE: PLANS PRINT FULL SIZE AT 11X17N� 019SEPARATE PERMITS ZONING+DEVELOPMENT CITY OF TIGARD-TITLE 18 COMM. DEV. CODESHEET INDEXBUf ®BUILDING CODE 2014 OREGON STRUCTURAL SPECIALTY CODE ®� ELECTRICAL-SUBMITTED UNDER SEPARATE COVER ARCHITECTURAL FIRE SPRINKLER -SUBMITTED UNDER SEPARATE COVER MECHANICAL CODE 2014 OREGON MECHANICAL SPECIALTY CODE MECHANICAL-SUBMITTED UNDER SEPARATE COVER PLUMBING CODE 2017 OREGON PLUMBING SPECIALTY CODE A0.00 PROJECT INFO AND VICINITY MAP PLUMBING-SUBMITTED UNDER SEPARATE COVER A1.00 SITE PLAN AND CODE ANALYSIS W ELECTRICAL CODE 2017 OREGON ELECTRICAL SPECIALTY CODE A2.10 EXISTING AND DEMO PLANS ~ Nie w ACCESSIBILITY STANDARDS 2014 OSSC, ICC/ANSI 117.1 2009 A2.20 NEW WORK PLANS C/ I— PROJECT GENERAL NOTES A4.00 CEILING AND WALL DETAILS Cl) o W A5.00 ADA DETAILS- DOORS AND CLEARANCES I a 1. DRAWINGS ARE DIAGRAMMATIC AND DO NOT NECESSARILY DEPICT ALL MATERIALS IN ALL INSTANCES. A5.01 ADA DETAILS- PLUMBNG FIXT.AND MOUNTING HTS. IY Q 2. DO NOT SCALE DRAWINGS;WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. 0 I- 0 O 3. CONTRACTOR TO VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO CONSTRUCTION AND PURCHASE OF MATERIALS.ANY O M Z d DISCREPANCIES BETWEEN FIELD MEASUREMENTS AND DRAWINGS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE = LLJ 2 Q ARCHITECT. m O I al 4. ALL DIMENSIONS ARE FROM FACE OF FRAMING OR GRID UNLESS OTHERWISE NOTED.SEE ASSEMBLIES WHERE APPLICABLE. w 5. DRAWINGS REPRESENT THE FINISHED STRUCTURE,THEY DO NOT INDICATE METHOD OF CONSTRUCTION. CONTRACTOR SHALL ASSUME OFFICE COPY �j O Z p O RESPONSIBILITY FOR DETERMINING APPROPRIATE METHOD AND SEQUENCE OF CONSTRUCTION. ( /° d//1-00.(3/4./ 6. DETAILS NOTED AS"TYPICAL"OR"TYP"APPLY IN ALL CASES UNLESS SPECIFICALLY REFERENCED. DETAILS THAT ARE SPECIFICALLYA —J = L.1 0 Ln REFERENCED SHALL TAKE PRECEDENCE OVER ALL OTHER GENERAL OR TYPICAL NOTES. l 525 MVV ����`°,•, � (A 1..n ce Q 7. CONTRACTOR SHALL ENSURE THAT ALL WORK IS EXECUTED IN COMPLIANCE WITH ALL GOVERNING CODES,STANDARDS AND REGULATIONS. AB BREVIATI O N S I Ln 0 8. CONTRACTOR TO COORDINATE AND PROVIDE ALL CODE REQUIRED SIGNAGE UNLESS OTHERWISE INDICATED. 9. PROVIDE ACCESS PANELS AS REQUIRED. LOCATION, FINISH,AND TYPE SHALL BE APPROVED BY ARCHITECT PRIOR TO OBTAINING AND AFF ABOVE FINISH FLOOR INSUL INSULATION INSTALLING. MATCH RATING TO ASSEMBLY IN WHICH THEY ARE INSTALLED AND PROVIDE SMOKE SEALS WHERE RATINGS ARE REQUIRED. AD) ADJACENT INT BO BOTTOM OF MFR MINAERIOR DATE: 11/01/2019 ANUFACTURER 10. ALL RATED ASSEMBLIES SHALL BE CONSTRUCTED TO PREVENT THE MOVEMENT OF HOT FLAME OR GASES PER OSSC SECTION 709.6.ALL CLNG CEILING MAX MAXIMUM $)6 DEMO PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE FIRESTOPPED. Cj CNT MIN MINIMUM CL CEENT NTERRLINEUNE mu METAL REVISIONS 11. CONTRACTOR TO PROVIDE SAFETY GLAZING AT ALL LOCATIONS REQUIRED BY CODE AND SHALL BE PERMANENTLY LABELED WITH THE CLR CLEAR MC NOT IN CONTRACT MANUFACTURER'S NAME AND TEST APPROVAL INFORMATION. SEE WINDOW AND DOOR SCHEDULE. CONT CONCRETE OAE OR CONT EQUAL CONT CONTINUOUS OC ONN CENTECENTER 12. ALL MECHANICAL, ELECTRICAL,AND PLUMBING TO BE DESIGN-BUILD UNLESS OTHERWISE INDICATED. CONTRACTOR TO PROVIDE ALL DIMS DIMENSIONS OF/CI OWNER FURNISHED,CONTRACTOR INSTALLED DOCUMENTATION INCLUDING SHOP DRAWINGS THAT ARE NECESSARY FOR CONSTRUCTION AND PERMITS. PROVIDE SYSTEM DESIGN ELEV ELEVATION OF/01 OWNER FURNISHED,OWNER INSTALLED Q EQ EQUAL OPH OPPOSITE HAND DRAWINGS TO ARCHITECT FOR REVIEW IN PRIOR TO PERMIT SUBMITTAL. (E) EXISTING PT PRESSURE TREATED [t EXT EXTERIOR RD ROOF DRAIN N 13. ALL SUBSITUTIONS TO BE SUBMITTED TO AND APPROVED BY THE ARCHITECT PRIOR TO CONSTRUCTION. FD FLOOR DRAIN RO ROUGH OPENING PROJECT INFO AND 0• 14. PROVIDE SHOP DRAWINGS FOR ALL CASEWORK. VERIFY MATERIALS&PRODUCTS TO BE SUBMITTED FOR REVIEW WITH THE ARCHITECT. FE FIRE EXTINGUISHER SD SMOKE DETECTOR 15. CONTRACTOR TO KEEP AREA OF WORK FREE OF TRASH AND DEBRIS ON A DAILY BASIS, PROVIDE FOR ON—SITE RESTROOM FACILITIES AND FF FINISHED FLOOR SF SQUARE FOOT(FEET) VICINITY MAP FO FACE OF SS STAINLESS STEEL El, MAKE ANY OTHER NECESSARY PROVISIONS TO PROTECT FINISHED ELEMENTS AND MAINTAIN A CLEAN, SECURE,AND WEATHER-MANAGED GA GAUGE SIM SIMILAR N WORK SITE. PROVIDE EROSION CONTROL AND DEBRIS MANAGEMENT AS NECESSARY PER LOCAL CODES. GB GYPSUM BOARD To TOP OF co HM HOLLOW METAL TYP TYPICAL 16. CONTRACTOR TO PROVIDE ABATEMENT AND POLLUTION CONTROL AS NECESSARY FOR ALL REMOVED MATERIALS. HT HEIGHT UON UNLESS OTHERWISE NOTED A0 . 00VIF VERIFY IN FIELD 17. COORDINATE AND PROVIDE COMPLIANT MODIFICATIONS TO EXISTING FIRE ALARM AND/OR FIRE SPRINKLER SYSTEMS AS REQUIRED. BUILDING CODE ANALYSIS OSSC STRUCTURAL SPECIALTY CODE(OSSC)2014 :3 , ILT CONSTRUCTION TYPE: IIIB,SPRINKLERED ARCHITECTURE, LLC 711 r--.T... :� Vu (E)OCCUPANCY GROUPS: B(D6), 2808 NE MLK,ste G / BUILDING HEIGHT: 1-STORY PORTLAND, OR 97212 ( C1 ) ; (E)BUILDING AREA: 9,649 SF+/-(D) 503.454.6793 / I ALLOWABLE BLDG.AREA: 19,000 SF(PER TABLE 503) ( C2 ) ( C3 ) (C4-C6) AREA OF WORK: 2,148 SF(D6)= inkbuiltdesign.com C 11535 I �,'��'���ARer / % TABLE 508.3 NON SEPARATED OCCUPANCIES ♦ ;1 IAD. btars / I a G 1 I I NO SEPARATION REQUIRED. ' ► ,rl.. I E ADA PARKING 1008.1.9.3 EXCEPTION 2: �.r,; r: o ��' . WHERE LOCKS AND LATCHES ARE PROVIDED AT MAIN EXTERIOR DOORS, L SPACES TO REMAIN, cI' �;��"�" PROVIDE SIGNAGE STATING"THIS DOOR TO REMAIN UNLOCKED WHEN / t� ��.� � __ _- TYP. OF OgQ, a jab � BUILDING IS OCCUPIED" OD 1014.3 COMMON PATH OF TRAVEL REQUIRED:MAX 75' WTABLE 1015.1 D6 / '� NUMBER OF EXITS REQUIRED: TBD / < Or o NUMBER OF EXITS PROVIDED: 3 r :� 1 TABLE 1016.2 EXIT ACCESS TRAVEL DISTANCE:MAX 200' / ` TABLE 1018.2 MINIMUM CORRIDOR WIDTH=44",>50 OCC. V ( D1 ) W / y,1`� . D6 » ` 1015.2.1 EXP.2 TWO EXITS SEPARATION ~ w a / V f D2 s . IN BUILDINGS EQUIPPED WITH AUTOMATIC SPRINKLERS-EXITS SHALL NOT — QQ` / ( 63 ) ���' ( ) �' E 11515 BE LESS THAN 1/Q3 THE LENGTH OF THE OVERALL DIAGONAL OF THE AREA f� , s ` �� 11, SERVED. ► � a // iiii11111,4,iiiipirlip...„ ( D3 ) t , O!� (E4-E5) EiQD 11525F ( D5 ) �a / CHAPTER 29 PLUMBING (E)ADA BATHROOMS TO REMAIN. Oa 2 libEg 0 a/ B1 ' .45 o ` (o '� `05oc� N / O w err' m 1— �„ / Ai 117,, 7.1. !moi. /1144"44%. &E9 ) oo. :,.it_ w I� �� r - litt O -d am CO; J r N In W At ' Ln ...- (41 rY 11111110 figf /' / DATE: 11/01/2019 / QOM .11111.1P 4MMEI / A 11555A1-A3 / *-D6 DEMO REVISIONS 41111114000016 - AREAS OF WORK Diet 04 Li SW / d; D�R�q� SITE PLAN AND N Ru40 CODE ANALYSIS 0 0 N 1Dr:i SITE PLAN - B2 D6 1"=60'-0" A 1. 0 0 PLUMBING FIXTURE CREDITS DEMO LEGEND DEMO PLAN NOTES jef.B _ ILT FIXTURE #EXISTING #REMOVED #NEW FIXTURES NET TOTAL CREDITS EXISTING CONSTRUCTION TO REMAIN A. REMOVE ALL CONSTRUCTION ARCHITECTURE, LLC FIXTURES COMPLETE. REMOVE ALL UN-USED WATER CLOSET V 0 0 t 0 D _ _ _ (E)CONSTRUCTION TO BE REMOVED CONDUIT, PIPING AND WIRING 2808 NE MLK, ste G LAVATORY Z i m 1 1 COMPLETE COMPLETE. PORTLAND,OR 97212 HAND SINK 1 1 0 0 0 B. MAINTAIN EXISTING FIRE SPRINKLER 503.454.6793 KITCHEN SINK S 2 0 1 Z SYSTEM,TO BE PERMITTED AND inkbuiltdesign.com SHOWER 1 1 0 0 1 MODIFIED UNDER SEPARATE PERMIT. WATER HEATER 0 0 0 C. EXISTING REMAIN. ELECTRICAL SYSTEM TO �4)1$D ARch. D. ALL EXISTING SUPPLY AND RETURN �` ; IAD. �� DUCTWORK TO REMAIN. W " '�'% C f�I*j/f' ot., Y . s.,i !/ / OF 'a� (E)CEILING,LIGHTING , AND MECH.TO REMAIN. / (E)SUSP.CLNG.TO REMAIN. aaTn a VACA s2 )T �a�� / BLDG ELEC I I I I r- I I O LLJ ( '� I III �L I I I C!) �II / II ......n.71..... — 1f— —ll I � fl (► ; � O w I`� i DEMO(E)SINK,SALVAGE �.�.� , -. � : �}r L_ _ I �-_�-� I I (- - - -� (��°i Ll II- - C� 0 FOR RE-USE C - I 1111 II - - " a Q CL — � �I / NII II 1 —J I I O O z c Atm:,---)-- . ;1 VACANT - - o. � I �� I I O w 2 N REMOVE(E)SINKS, o- I --., } Lt I- Cil CAP PLUMBING Eli / m C) INSIDE WALL. = ; r (D >Lu a ce PATCH AND - KV -- � �� ��� REPAIR WALL. -� l�, � ' I �i r ® , — — �.r:.� — aaaa�.��=—� �` � � � ,,,, v., 0c, REMOVE(E)CABINET AND IJ E �T - - 71 -7 T-1 SINK II 11 Ln Ce J N Q (� �� REMOVE(E)WATER HEATER .. n.. a _... , HH I Q . l7 ` `�I � RELOCATED(E)ELEC.PANEL (E)BATHROOM AND H� TO OTHER SIDE OF WALL. BREAK ROOM TO DATE: 11/01/2019 , r1; REMAIN. H° I L L_� i !-D6 DEMO 1 H 119 I REVISIONS Iffii I N. j i l I 7 2 �y, ADJACENT TENANT I H L r H DR. RICHARD L 61 I i WIPPLE DDS E, EXISTING AND ( D1 � DEMO PLANS ® ,0 N 00 EBO SUITE B2 — EXISTING AND DEMO PLAN �O SUITE D6 — EXISTING AND DEMO PLAN A2 . 1O NEW WORK LEGEND FLOOR PLAN NOTES :3 „ ILT I I EXISTING CONSTRUCTION TO REMAIN A. SEE A5.00,A5.01 FOR TYPICAL ADA REQUIREMENTS,CLEARANCES, ARCHITECTURE, LLC • PROVIDE MTL.STUD WALL TO MATCH(E) MOUNTING HEIGHTS AND A4.00 FOR 2808 NE MLK, ste G TYP. WALL DETAILS. PORTLAND, OR 97212 B. ALL DAMAGED,ALTERED,OR REWORKED 503.454.6793 AREAS SHALL BE PATCHED AS REQUIRED inkbuiltdesign.com AND FINISHED TO MATCH EXISTING CONDITIONS OR AS SPECIFIED TO 41D Akc 4 PROVIDE A"LIKE NEW" FINISH. ,'% C. INSULATION-PROVIDE SOUND BATTS AT eti 4 t►AD. ALL NEW INTERIOR WALLS AND ,fr, �. _-Y- ikii CEILINGS. W � Cp. D. DOOR HARDWARE ALL NEW HARDWARE '' ." ° TO BE LEVER TYPE, FULLY ACCESSIBLE. E. ALL NEW WALLS MATCH HEIGHT OF 'i OF 0S'46 EXISTING WALLS. F. PATCH/REPAIR AND PAINT ALL NEW AND EXISTING WALLS-COLOR AS SELECTED BY OWNER. GG (E)SUSP.CLNG.TO REMAIN. REPLACE !iY ,,. A ANY DAMAGED TILES. (E)HVAC TO REMAIN. i H LU s 1,4 1 ACANT' BLDG ELEC 1 - w B2 O a PROVIDE NEW 3-$'7-0 SC RELOCATED SINK WD.DOORS,PAIN - a Q PROVIDE ACCESS.L ER l`e' (E)SUSP.CLNG.AND LIGHTING AND MECH. 0 c0 H 2 VACANT TO REMAIN, 0 G w 2 N HARDWARE AND v` r II} - ' N ( 06 ) CO C3 PRIVACY LOCK TO �1 ' �1`. WILLOWBROOK �_` I0 `n- — STANDARD '`� Fel ELEC. NEL I PROVIDE NEW 6 GAL. _J _,_— RELOCATED to 0 WATER HEATER ABOVE �� J I 'n Q i 1, RESTROOM CEILING. � ..,.�,..� .,. a .�.E J. ��� .a Q 0 REPLACE(E)V ITY LIGHTS IN 51 1 " _ ~ RESTROOM ITH NEW LEDo PROVIDE NEW MTL.STUD (E)BATHROOM AND LIGHTS WALL TO BOTTOM OF SUSP. BREAK ROOM TO DATE: 11/01/2019 !i s CLNG.,PAINT TO MATCH REMAIN. ADJ.WALLS,SEE A4.00 I.) . #D6 DEMO I I REVISIONS ire-- — II 2 ADJACENT TENANT Q I DR. RICHARD I I oi I _ WIPPLE DDS I I NEW WORK PLANS N , i .. H ( D1 ) ', , o E, A.----- - g_ N 00 A2.20 ED SUITE B2 - NEW WORK PLAN e0 SUITE D6 - NEW WORK PLAN WALL BRACING WALL TYPES SUSPENDED CEILING " : 3 , ILT ARCHITECTURE, LLC TWO FIXTURE HANGING AT LATERAL WALL OPPOSITE CORNERS SECURED 2808 NE MLK,ste G BRACE ABOVE TO STRUCTURE CEILING.ALTERNATE PORTLAND, OR 97212 DIRECTIONS TO '' TWO(2)MAIN 503.454.6793 .60 STRUCTURE,SEE PARTITION WALL \ / SEE PARTITION WALL BRACING DETAIL RUNNER LIGHT BRACING DETAIL CLIPS AT OPPOSITE inkbuiltdesign.com �� `-. CORNERS 4 4 UNDERSIDE OF STRUCTURE COMPRESSION S. �� '4 , �I♦� LATERAL WALL BRACING 4 FEET O.C. , O.C.EACH WAYPOST AT 12 T : e ".:0,,s ALTERNATE DIRECTIONS , �4� �� �A� ) �� ACOUSTIC BATT INSULATION TO 4'ONcza EACH SIDE OF PARTITION WALL AT i., 'f J� C /LLP OFFICES AND RESTROOMS X /� SUSPENDED CEILING SYSTEM ji � •/ f: !� 4 NEOPRENE FOAM TAPE CONT.BETWEEN BLOCKS �� L . - ;r S 4 CASING BEAD L � \., FASTEN RUNNER TO CEILING SUPPORT AT 2 '" i TI FEET O.C.THRU NEOPRENE BLOCKS ANGER WIRE AT 45 DEG. OF O ACOUSTIC BATTS AT OFFICE AND BATHROOM WALLS FOUR WAYS MAIN W 5/8"GYPSUM BOARD `"1 RUNNER '•� SPACING AND HEIGHT SCHEDULE/ METAL STUDS,SEE FOR GUAGE, GRID FIXTURE HOUSING,WRAPPED SAFETY WIRE ATTACHED TO G _, AROUND FIXTURE HANGING WIRE MIN. PARTITIONS FOUR TIMES.SECURE AT DIAGONAL CORNERS NOT CONTAINING MAIN LATERAL WALL BRACING IN LIEU ACOUSTIC SEALANT AT SLAB RUNNER LIGHT CLIPS CROSS I, OF BRACING ABOVE CEILING NOTE: RUNNER PROVIDE ADJACENT WALL 0,1450 POWDER ACTUATED DRIVE PIN WITH REQUIREMENTS ARE FOR LIGHT FIXTURES WEIGHING 56 LBS.OR LESS.LIGHT FIXTURES LU FRAMING FOR LATERAL SUPPORT 1/4 INCH EMBEDMENT AT 4'O.C.MAX INTO WEIGHING MORE THAN 56 LBS.TO BE INDEPENDENTLY SUPPORTED FROM STRUCTURE. WALL LATERAL BRACING ON WALL PARTITION WALL TO GRID CEILINGDECK RECESS MOUNTED FIXTURE SUPPORT ~ W (r) CO CL IBC METAL STUD TABLE-MAX WALL HEIGHT LU CL MAX WALL HEIGHT 00 STUD GUAGE STUD SPACING SIZE DESIGNATION COMPOSITE NON-COMPOSITE O d 0 SECTION SECTION I" C 3 5/8" 25 362 S 125-18 16" 16'-2" 12-2" / O W N 24" 13-2" 9'-11" (E)ROOF -- /l"�'\\ �'�/ W N c Q 20 362 S 125-30 16" 20-8" 23-3" STRUCTURE 4X4 BLOCK W/A35 CLIPS W(4)#6 X 1/2"SPAR �+ G 24" 18'-1" 18'-11" SCREWS AND(4)8d X 1-1/2"NAILS EACH SIDE CO Q N 1 Ol 6" 25 600 S 125-18 16" 20-1" 7 BRACE TO MATCH WALL WIDTH W/33 MIL LUD 24" 16'-4" -- 6,::', THICKNESS,MIN. CO -j. Q p[ 20 600 S 125-30 16" 30'-8" 30'-1" Q O Q Z Q 24" 25-0" 26'-3" tl, — _ _ I = N 0 ��` VALUES LISTED ARE BASED ON STEEL STUD MANUFACTURERS ASSOCIATION Ufl EdL (SSMA)TABLES FOR NON-STUCTURAL COMPOSITE SECTION IN INTERIOR �•I J CLIP FLANGES AND BEND EACH ce lfl� Q APPLICATIONS(5 PSF)WITH DEFLECTION LIMIT OF U120. END. Q U' 6 #10 SCREWS EACH END OF 1. VALUES FOR COMPOSITE SECTION REQUIRES 5/8"MIN.GYP.BD.ON BOTH � BRACE EQ.SPACED ~ SIDES W/#6 TYPE S DRYWALL SCREWS AT 12"O.C.FOR STUDS AT 24"OC AND : 16"OC FOR STUDS AT 16"OC. WALL PER PLANS 2. HEIGHT LIMITS ARE LESS WHERE SHEATHING IS ON ONE SIDE.PROVIDE d DATE: 11/01/2019 BLOCKING OR STRAPPING ON OPPOSITE SIDE(NON-COMPOSITE VALUES). 1-D6 DEMO NOTE:BRACE CONNECTION AT ROOF TO FRAMING SCHEDULE PARTITION WALL BRACING DIRECTLY ATTACHED TO PLYWD. REVISIONS 2 Q m CEILING AND WALL N o DETAILS 0 N CO s- A4 . 00• 0 0 DOORS CLEARANCES NOTES i : LILT PULL SIDE APPROACH PUSH SIDE APPROACH ACCESSIBLE ROUTE INDICATOR LINE " . I "' 7 r REFERENCE CODE SUMMARY SHEETS FOR 24" THESE DIAGRAMS ARE BASED OF THE INFORMATION ARCHITECTURE, LLC - /v/-/ EXTENT OF ROUTE CONTAINED IN ICC A117.1-2009 AND CHAPTER 11 OF THE z � � MAX I 2808 NE MLK,ste G z g / ' BUILDING CODE. THEY ARE REPRESENTATIVE OF THE PORTLAND, OR 97212 32" X/ ll % GENERAL REQUIREMENTS THAT APPLY TO THIS PROJECT. 503.454.6793 v ' �r z Z _/ - z - 'z THEY ARE NOT REPRODUCTIONS OF THE INFORMATION o O ' MIN � �� ` _ _�.,, N, _ _ _ _ inkbuiltdesign.com �° o p � 18" MIN / , / �� /0 24" m "' ' CONTAINED IN THE ICC A117.1 2009. REFER TO THE ICC q 24" PREFERRED ' I / / j/O `-•km- A./ A117.1-2009 FOR ADDITIONAL INFORMATION. ,0])A id, o �, �, z W Q O z Q L.9 S 9r� ,r 32 .' o / Q3' _ � Oo � v0 Buz �� 4� SAD. tiS MIN o / o o ¢ ¢ C �' z a W ' 'We C ri X=12"MIN WHEN DOOR z _ u o o z ce < o HAS CLOSER AND LATCH o Xa Lu w c4 z J ,�FRONT APPROACH N n z = - v v �� S ;r 0 0 0 2 cp t '"� PULL SIDE PUSH SIDE 12" R`�� 3 r77MIN.*�x X TYPICAL ACCESSIBLE ROUTE OF OF 0 o ': v60" MIN 60 Q 4I cc />- o r -V1 I 1 z• z • 12" 36" 12.. ( o o X ¢ 22" 32°/ 1 N I1 0.o ��� /MIN. lirMIN N f 32" jrc, *IF DOOR HAS o L_LU..1 MIN oo BOTH LATCH ' N X=36"MIN WHEN Y=60" o // AND CLOSER \ // m 5 C/ H X=42"MIN WHEN Y=54" u: O HINGE APPROACH o.. 60"DIAMETER TURNING CIRCLE T SHAPED SPACE FOR 180 TURNS �j 00 a. PULL SIDE PUSH SIDE ADDITIONAL INFORMATION � � z � � I/ FIGURE 304.3 O M w v � N z 1 / 40 ' ¢O z / 0 L.G.. W 03 C3 2 = rn } 0 24" MIN a a w Q _ 00 ' o rr Q 32" 24" MIN ¢ a 2 2 Is r A MIN /` — ;" 1 0 = 32" 1 Ln ce MIN X o // CHANGE IN LEVEL-SQUARE CHANGE IN LEVEL-SLOPED Q Ln l� o / _ t- j--- Y=54" - Y=54"MIN IF DOOR HAS LL- Y=48"MIN IF DOOR HAS CLOSER CLOSER LEVEL CHANGE ON FIGURE 303 DATE: 11/01/2019 LATCH APPROACH TREAD y11"y /12";'DOOR CLEARANCES AT SWING FIGURE 404.2.3.2 DEPTH MINI MIN •-D6 DEMO -, [C LANV REVISIONS jr 32" MIN i - 2/ - M Q �� � POCKET OR SLIDING DOOR � � o r N o 1 ADA DETAILS - o D 9 = DOORS AND , 32" jr 32" MIN CLEARANCES o MIN 00 SWING DOOR BIFOLD DOOR - P DOOR CLEARANCES AT DOORS FIGURE 404.2.2 STAIR HANDRAILS FIGURE 505.10.2 AND .3 A5 . 00 PLUMBING FIXTURES MOUNTING HEIGHTS w MIRROR LAVATORY LAVATO NOTE:WALL MOUNTED DEVICES SHALL NOT EXTEND MORE THAN 4"BEYOND WALL SURFACE miligf 3 `-' I L I R 161/4" MIN 11J 2 36" MIN 3g'XMIN WHEN LOCATED BELOW 6'8" ARCHITECTURE, LLC VI u z z E o // z O18" 2808 NE MLK,ste G ~ PIPE WRAP f- 18" 18" 18' n�i MIN MIN PORTLAND, OR 97212 `�' 7/ TYP a, `" p --\- �----- - -� - 503.454.6793 IM� 4` E� �� % \-- i i — • • inkbuiltdesign.com � --o �� m 19" MAX d Or _ MAX HEIGHT TO ALLKNEE CLEARANCE t I48" z drL, OPERABLE PARTS o = /LSD A}� AREA 1 e 0 a '��' C r LAVATORY CLEARANCE , 5 AD ,�► LAVATORY KNEE , 48" MINI Q ` ROBE TOWEL HAND ` SEAT PAPER TOWER SANITARY '� `'' , 'r C CLEARANCE AND 8" MIN 6" MAX TOCLEARANCE � ; ' ®� HOOK BAR TOWEL COVER DISPENSER NAPKIN ,; f f MIRROR MOUNTING ,�/ 48" MIN e''4%C e .fr CLEARANCE AT LAVATORY lin 17" MIN DEPTH FIGURE 606 APPROACH 1 2 BAR DISPENSER DISPENSER �>L. '^JJ . 1 •`�►, (8c, 36" R.O. CEILING OF 00 TRANSFER SEAT 15" MAX. 18" 42" z 3"MAX 14" BACK ' in -- PROJECTION MIN . z _ rill ���� co- �` .6, 'ci 'z'c Abj m m Lu 32" I .;:, z .= MA 1 2_ J MIN 24 �,/fiwi 2 Li- " X- \ J E O>, ,..., 0 z V T . LnA Er2.:,(-- t LL L � o a z , a Ln Q o MT W 03 LI, 0 m i A APPROACH i u, C/ 1- 3'X 3'SHOWER BLOCKING FOR GRAB BARS Jr 60" MIN ` \ ` \ \ \ _ ! a \ \ C3 i) a AT SHOWER LOCATIONS FEC HORN/ STROBES THERMOSTAT/ ROOM O p URINAL MOUNTING HEIGHT CLEARANCES AT SHOWERS FIGURES 608 CLEARANCE AT WATER CLOSETS FIGURE 604.3 STROBE SECURITY/ SIGNAGE Se a Q 6" MAX FIRE ALARM 0 �c c 1- 2 36" MIN AREA OF BLOCKING FOUNTAIN WALL MOUNTED DEVICES AND APPLIANCES CD G z 2 N AT FRAMED WALL 58 Np 17"- 19"----Jr 30" DEPTH 30" CX Ll.! 2 Q ICI F- al 12" MIN NOTES m 0 L' 52"TYP H F ♦ �j ��::�r n �i z z O ;D THESE DIAGRAMS ARE BASED OF THE INFORMATION CONTAINED IN THE ICC z U , O� �_ o i� A117.1-2009 AND CHAPTER 11 OF THE BUILDING CODE. THEY ARE REPRESENTATIVE I = cn p u A �t v U T � ream."- ' •� OF THE GENERAL REQUIREMENTS THAT APPLY TO THIS PROJECT. THEY ARE NOT N OQ J Q :��a. a' ~c� REPRODUCTIONS OF THE INFORMATION CONTAINED IN THE ICC A117.1-2009. REFER : Q ,-- z �_ 0 TO THE ICC A117.1-2009 FOR ADDITIONAL INFORMATION. _ `�'` i ' " a, FREE-STANDING FIXTURE BUILT-IN FIXTURE DATE: 11/01/2019 Jr, 18" TP 3 -3" EQUIPMENT 48" MIN •D6 DEMO GRAB BARS AT WATER CLOSETS FIGURES 604 17"_ 19" nO PERMITTED IN REVISIONS SHADED AREA INT' Z g r,/ 0 ON o. \ - _ 0 W ~ H �- ,- c- g = 8 111FAZ///1 j I N _o - p m 17"- 19" ADA DETAILS N \L) \ + z\ 8" MIN 24" MAX PLUMBNG FIXT. AND Al • oN OUTLET SWITCH OUTLET ABOVE FIRE ALARM PULL F, �� FIXTURE IN ALCOVE MOUNTING HTS. - CO COUNTER STATION N a, 6 MAX 1 TOILET ROOM ACCESSORY MOUNTING HEIGHTS WATER COOLERS AND DRINKING FOUNTAINS FIGURE 602 A 5 . 0 1