Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (2)
12442}2 ScN-o.L PivRRy FP52ol9 00139 Honeywell I Addressable Devices tranewell Velociti® Series 3 Detectors Photoelectric Detectors Description The Gamewell-FCI,Velociti=Series 3 intelligent photoelectric detectors with integral communication provide point location for alarm communication and selective maintenance.Designed in a modern bright white color,the Velociti Series 3 is aesthetically pleasing for today's contemporary buildings. The Velociti Series 3 smoke detectors are intelligent addressable detectors with point ID capability that enable each detector address to be set with rotary address switches providing exact device locations,The photoelectric detector continually monitors the detected temperature and reports it to the fire alarm control panel.The modern design and expanded color options support a variety of contemporary aesthetic demands.In addition,each detector is constructed for exceptional installation and maintenance efficiency. The Gamewell-FCI,ASD-PL3 photoelectric detector's re-designed optical sensing Photoelectric Detector chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards.The sensitivity of Velociti series detectors can be programmed using the control panel software to suit the environment.The ASD-PL3R photoelectric detector is also remote test capable that may be used with a DNR(DNRW)duct smoke detector housing.The ASD-PTL3 multi- sensor detector offers either photoelectric detection or thermal detection through dual.electronic thermistors at 135°F fixed temperature thermal sensing. For legacy installations,service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility.Service models are designated by the-IV part number after the detector model. Note:Although the E3 Series('and S3 Series panels support both the Velociti°and CLIP''protocols,the GWF-7075 panel does not support the CLIP protocol.To obtain a complete list of panels that are listed to Velociti Series 3 detectors,refer to the Compatibility Addendum for Gamewell-FCI Manuals,P/N:9000-0427-L8. FEATURES & BENEFITS • Complies with UL' • Contains a built-in • Provides rotary address • Includes dual LEDs for • Offers expanded color Standard 268 7th functional test switch switches(01-159) 360°visibility options Edition activated by external magnet • Supplies optional relay, • Designed with a new isolator,or sounder profile to offer modern • Supports a tow standby bases(standard or low and improved current frequency) aesthetics Ordering Information Ordering Information NOTE:"-IV"suffix indicates Ivory color model. Accessories NOTE:"-BL"suffix indicates Black color model. SMB600:Surface Mounting Kit(flanged) NOTE:"WH"suffix indicates Bright White color model. ASD-PL3:Photoelectric smoke detector,bright white, TR300:Accessory Flange Ring for B300 6"Base,bright Velociti white ASD-PL3R:Photoelectric smoke detector,remote test TR300-IV:Accessory Flange Ring for B300 6"Base,ivory capable,for use with DNR(W)duct smoke detectors,bright RA100Z: Remote LED annunciator,3-32 VDC white,Velociti The annunciator mounts to a U.S.single-gang electrical ASD-PTL3:Photoelectric smoke detector with thermal box.For use with B501 and B300-6. sensing,bright white,Velociti CK300: Bright White detector kit(Pack of 10) ASD-PL3-IV:Photoelectric smoke detector,ivory,Velociti/ CK300-IR: White,detector color kit for use with MCS-COF CLIP Series Detectors.(Pack of 10) ASD-PL3R-IV:Photoelectric smoke detector,remote test CK300-IV: Ivory,detector color kit.(Pack of 10) capable,for use with DNR(W)duct smoke detectors,ivory, CK300-IR-IV: Ivory,detector color kit for use with Velociti/CLIP MCSCOF Series detectors.(Pack of 10) ASD-PTL3-IV:Photoelectric smoke detector with thermal CK300-BL: Black detector kit.(Pack of 10) sensing,ivory,Velociti/CLIP CK300-IR-BI: Black,detector color kit for use with Intelligent Bases MCSCOF Series detectors.(Pack of 10) For details on intelligent bases,refer to Data Sheet M02-04-01: Detector test magnet. P/N:9021-60540. M02-09-00: Test magnet with telescoping handle. Note:"IV"suffix indicates Flashscan and CLIP devices. XR2B: Detector removal tool.Allows the installation and/ "WH"suffix indicates bright white or removal of the detector heads from the bases in high B501-WHITE: 4"Flangeless mounting base,bright white ceiling applications. B501-WHITE-BP:4"Flangeless mounting base bulk pack, XP-4: Extension pole for XR2B.Shipped with three,5-foot bright white (1.524,m)sections. B501-IV: 4"Flangeless mounting base,ivory B300-6: 6"Flanged mounting base,bright white B300-6-IV:6"Flanged mounting base,ivory B300-6-BP:6"Flanged mounting base bulk(Pack of 10) B200SR-WH:Standard sounder base,bright white B200SR-IV:Standard sounder base,ivory B200S-WH:Intelligent addressable sounder base,bright white B200S-IV:Intelligent addressable sounder base,ivory B200SR-LF-WH:Standard low frequency sounder base, bright white B200SR-LF-IV:Standard low frequency sounder base, ivory B200S-LF-WH:Intelligent addressable low frequency sounder base,bright white B200S-LF-IV:Intelligent addressable low frequency sounder base,ivory . B224RB-WH:Relay base,bright white B224RB-IV: Relay base,ivory B224B1-WH:Isolator base,bright white B224B1-IV: Isolator base,ivory DNR: Intelligent duct detector housing,non-relay DNRW: Intelligent duct detector housing,non-relay, watertight 2 Velociti® Series 3 Detectors Technical Specifications SYSTEMS STANDARDS For a complete listing of all compliance approvals and Photoelectric Intelligent Detector: The Velociti'i Series 3 Photoelectric Detectors are certifications,please visit. Physical Specifications designed to comply with the following standard: http://www.gamewell- Height: 2.0 inches(51 mm)installed in B300-6 base UL Standard:UL 268 fci.com/en-US/ documentation/Pages/ Diameter: AGENCY LISTINGS AND APPROVALS Listings.asp.aspx 6.1 inches(15.49 cm)installed in B300-6 base These listings and approvals apply to the modules E3 Series',VelocitH and 4 inches(10.16 cm)installed in B501 base specified in this document.In some cases,certain Gamewell-FCI°are registered Shipping Weight: 3.4 oz(96.4 g) modules or applications may not be listed by certain trademarks of Honeywell Operating Temperature Range: approval agencies,or listing may be in process. International Inc. Photo:32°F to 122°F(0°C to 50°C) Consult factory for latest listing status. Photo in Duct Applications:-4°F to 158°F UL:S2332 o UL Laboratories a registered trademark pp of Underwriter's L (-20°C to 70°C) FM:3023594 Inc. Photo with Thermal:32°F to 100°F(0°C to 38°C) MEA FDNY:COA-219-02-E Vol.VI This document is not intended Operating Humidity Range: 10%to 93% CSFM:7272-1703:0501 to be used for installation non-condensing ISO 9001 Certification purposes.We try to keep our Rate-of-Rise Detection:Responds to greater than product information up-to- 15°F/minute or 135°F(8.3°C/minute or 57°C date and accurate.We cannot cover all specific applications Air Velocity Range: 0 to 4,000 ft/min or anticipate all requirements. (0 to 1219.2 m/min) Allspecifications are subject to Electrical Specifications change without notice. Voltage Range: 15 to 32 VDC Standby Current(®24 VDC): 200 UA(one communication every 5 seconds with green LED enabled) Max Alarm Current(max.): 2 mA®24 VDC(one communication every 5 seconds with red LED enabled) Max Current(max.): 4.5 mA®24 VDC(one communication every 5 seconds with amber LED enabled) Isolator Load Rating: 0.0063 For more information Learn more about Gamewell-FCI's Velociti`°Series 3 Detectors and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford,CT 06472-1610 203.484.7161 9020-0617 I K 04/2018 Honeywell www.honeywell.com 02018 Honeywell International Inc. Honeywell I Addressable Devices QGamewell AMM-2F Addressable Monitor Module General The Gamewell-FCI Velociti®Series,addressable monitor module AMM-2F is a single Style B,Class B initiating device circuit(IDC)with a 47KW end-of-line resistor.This module provides an address for any device or group of devices connected to this circuit on the signaling line circuit(SLC)of the Gamewell-FCI addressable series fire alarm control panel.Any initiating device with normally open(N.O.)dry contacts may r be made addressable when connected to the AMM-2F module. The Velociti®Seriems use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls.These devices operate in a grouped fashion.If one of m the devices in the group has a status change,the panel's microprocessor stops the group poll and concentrates on the single device.The net effect is response speed up `F to five times greater than earlier designs. AMM-2F The AMM-2F module can be programmed to provide a wide variety of input functions to the Gamewell-FCI addressable series fire alarm control panels.It can be identified as a manual station,heat detector,plenum detector,waterflow switch,tamper switch, N.O.contact,smoke detector,projected beam smoke detector,sub loop,remote zone, etc.It can also serve as a remote system silence,system reset,system acknowledge or drill switch.It is even possible to customize its device type to meet specific job requirements. The initiating device circuit of the AMM-2F can support a maximum line resistance of up to 40 ohms allowing the use of linear heat detection devices.The compact size facilitates the installation of the module inside manual stations,or mounting boxes of various types of alarm initiating devices. Ordering Information AMM-2F:Addressable monitor module,single circuit,Style B,Class B FEATURES & BENEFITS • Compact size allows • Class B.Style 8, • 40 Ohm line resistance • Connects to any easy installation initiating circuit for each initiating normally open dry device circuit contact device AMM-2F Technical Specifications System STANDARDS For a complete listing of all compliance approvals and Supervisory Current:.000375 amps The E3 Series Control Panel is designed to comply with certifications,please visit: Alarm Current:.00060 amps the following standard: http://www.gamewell- Operating Temperature:32°to 120°F(0°to 49°C) UL Standard:UL 864 9th Edition fci:com/en-US/ documentation/Pages/ Relative Humidity:10 to 93°/o(non-condensing) AGENCY LISTINGS AND APPROVALS Listings.aspx End-of-Line Resistance:47K ohms These listings and approvals apply to the modules ° Dimensions:1.3"L x 2.5"W x 0.5°D are egi��and trademarks specified in this document.In some cases,certain are registered trademarks of (3.3 x 6.4 x 1.3 cm) modules or applications may not be listed by certain Honeywell International Inc. TEMPERATURE AND HUMIDITY RANGES approval agencies,or listing may be in process. UL®is a registered trademark This system meets NFPA requirements for operation at 0 Consult factory for latest listing status. of Underwriters Laboratories -49°C/32-120°F and at a relative humidity 93%+2% UL:S1949 Inc. RH(noncondensing)at 32°C±2°C(90°F±3°F). FM:3023594 This document is not intended However,the useful life of the system's standby batteries MEA FDNY:227-03-E VOL.IV to be used for installation and the electronic components may be adversely affected CSFM:7300-1703:0102 product information We try o keepupour extreme temperature ranges and humidity. Therefore, product We can it is recommended that this system and its peripherals be ISO 9001 Certification cove and specific accurate. cannot cover all specifiapplications installed in an environment with a normal room or anticipate all requirements. temperature of 15-27°C/60-80°F. Allspecifications are subject to change without notice. For more information Learn more about Gamewell-FCI's AMM-2F and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford,CT 06472-1610 203.484.7161 9020-0626 I F 111/17 Honeywell www.honeywell.com ©2017 Honeywell International Inc. .---s.s... • Gamewell Velociti® Series FciFIRE CONTROL INSTRJMEAOM-2RF by Honeywell Description Addressable Output Relay The Gamewell-FCI Velociti® Series, addressable output Control Module relay control module (AOM-2RF) allows a Gamewell-FCI analog addressable fire alarm control panel to switch dis- r r �� crete relay contacts by code command. The relay provides two isolated sets of Form-C contacts which transfer simul- -.- taneously. Circuit connections to the relay contacts are not supervised by the module. The Velociti® Series use a communication protocol that — substantially increases the speed of communication 411k, % 4P t between the SLC devices and certain Gamewell-FCI ana- log addressable fire alarm control panels. These devices AOM-2RF operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor Features stops the group poll and concentrates on the single device. • Listed under UL®Standard 864. The net result produces a superior response speed up to five times greater than earlier designs. • Offers two sets of Form"C"contacts. • Provides visual rotary,decimal switch addressing • The AOM-2RF Module is designed for installation in the (01-159). signaling line circuit of any Gamewell-FCI analog address- • Includes a bicolor LED that flashes green whenever the able fire alarm control panel.The module contains a panel module is addressed,and lights steady red upon controlled LED.The AOM-2RF is designed to mount in a 4" activation.* (10.16 cm)square junction box 2 1/8"(5.53 cm)deep. • Designed as a compact size to allow easy installation. Table 1 lists the relay contact ratings. Note:Only the red LED is operative in panels that do not operate Current Maximum Load in Velociti®mode. _Rating Voltage Description Application Specifications 3A 30 VDC Resistive Non-Coded 2A 30 VDC Resistive Coded Supervisory current: .000375 amps. 0.9A 110 VDC Resistive Non-Coded Alarm current: .0065 amps. 0.5A 125 VAC Resistive Non-Coded Operating temperature: 32°to 120° F(0°to 49° C) 0.5A 30 VDC Inductive Coded Relative humidity: 10 to 93% relative humidity (UR=5ms) (non-condensing) 1A 30 VDC Inductive Coded Dimensions: 4 1/2"H x 4"W x 1 1/4" (UR=2ms) (11.4 x 10.2 x 3.2 cm) 0.5A 125 VAC Inductive Non-Coded Ordering Information (PF=.35) 0.7A 75 VAC Inductive Non-Coded Part Number Description Table 1: Relay Contact Ratings AOM-2RF Addressable output relay control module SIGNALING 0 O . ; UL®is a registered trademark of Underwriter's Laboratories Inc. MEA *414 Velociti®Series is a registered trademark of Honeywell International Inc. LISTED APo S1913 3023599 4 219-02-E Vol.VI 7300-1703:0102 • \ 'gm GAMEWELL-FCI COMITY MIENS EENS 12 Clintonville Road,Northford,CT 06472-1653 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. 02014 Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0625 Rev.F page 1 of 1 \,