Loading...
Report (3) Msr209- DOL/25 1togcLf SKI boitlyais LSI Enphase Microinverters kt� En phase M215NOV I s 2019 ilPyrR f111'4 TIP rr els fi n' 1 a 22 The E rase M25 Micr'o`nver ` r1 with integrated ground delivers increased energy harvest and reduces design and installation complexity with its all-AC approach. With the advanced M215, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter.This further simplifies installation, enhances safety, and saves on labor and materials costs. The Enphase M215 integrates seamlessly with the Engage Cable', the Envoy Communications Gateway', and Enphase EnlightenTM monitoring and analysis software. PROD CTiVE Si KAP E RELIABLE -Maximizes energy production - No GEC needed for microinverter -More than 1 million hours of testing and -Minimizes impact of shading, dust, - No DC design or string calculation millions of units shipped and debris required - Industry-leading warranty, up to -No single point of system failure - Easy installation with Engage Cable 25 years 113 ENPHASE E 34116655 CERTIFIED h. S S4Y 1E Enphase®M215 Microinverter//DATA INPUT DATA (DC) M215-60-2LL-S22-IG, M215-60-2LL-S25-IG Commonly used module pairingsl 190-270+W Maximum input DC voltage 48 V Peak power tracking voltage 27 V-39 V Operating range 16 V-48 V Min/Max start voltage 22 V/48 V Max DC short circuit current 15 A OUTPUT DATA (AC) @208 VAC @240 VAC Peak output power 225 W 225 W Rated (continuous)output power 215 W 215 W Nominal output current 1.03 A(A rms at nominal duration) 0.9 A(A rms at nominal duration) Nominal voltage/range 208 V/183-229 V 240 V/211-264 V Nominal frequency/range 60.0/57-61 Hz 60.0/57-61 Hz Extended frequency range2 57-62.5 Hz 57-62.5 Hz Power factor >0.95 >0.95 Maximum units per 20 A branch circuit 25(three phase) 17(single phase) Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6 cycles H-- --,m EFFICIENCY CEC weighted efficiency, 240 VAC 96.5% CEO weighted efficiency, 208 VAC 96.5% Peak inverter efficiency 96.5% Static MPPT efficiency(weighted, reference EN50530) 99.4 0/0 Night time power consumption 65 mW max MECHANICAL DATA Ambient temperature range -40°C to+65°C Dimensions(WxHxD) 171 mm x 173 mm x 30 mm(without mounting bracket) Weight 1.6 kg(3.4 lbs) Cooling Natural convection- No fans Enclosure environmental rating Outdoor-NEMA 6 Connector type M215-60-2LL-S22-IG: MC4 M215-60-2LL-S25-IG:Amphenol H4 FEATURES Compatibility Compatible with 60-cell PV modules. Communication Power line Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in NEC 690.35.Equipment ground is provided in the Engage Cable.No additional GEC or ground is required.Ground fault protection(GFP)is integrated into the microinverter. Monitoring Enlighten Manager and MyEnlighten monitoring options Compliance UL1741/IEEE1547, FCC Part 15 Class B,CAN/CSA-C22.2 NO. 0-M91, 0.4-04,and 107.1-01 1.Suggestion only.Inverter self-limits DC inputs.Visit httos://enohase.com/en-us/support/module-compatibility to determine module size compatibility. 2.Frequency ranges can be extended beyond nominal if required by the utility To learn more about Enphase Microinverter technology, visit etnphase,con ENPHASE 2016-11-21 ©2016 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owner. www.hhi-green.com/solar/en --• ' t, a ,..._ t ,, .,.... , ,. .„„ ,,, y !4 : naa "° d - E ( LUe . . t . ul -,. •,,, ,, Hyundai Heavy Industries was founded in 1972 and is a Fortune 500 company.The company employs more than 48,000 people,and has a global leading 7 business divisions with sales of 51.3 Billion USD in 2013.As one of our core businesses of the company,Hyundai Heavy Industries is committed to develop and invest heavily in the field of renewable energy. Hyundai Solar is the largest and the longest standing PV cell and module manufacturer in South Korea.We have 600 MW of module production capacity and provide high-quality solar PV products to more than 3,000 customers worldwide.We strive to achieve one of the most efficient PV modules by establishing an R&D laboratory and investing more than 20 Million USD on innovative technologies. PERL Multi-crystalline Type Nov 1 9 Zda� HiS-M265RG HiS-M270RG HiS-M275RG RG-Series Mono-crystalline Type r r.r-=`, OF a r V�S�1rI•Q CS HiS-S280RG(HiS-5285RG I HiS-S29ORG I E f c OW �o( }l L''''''i' s Mechanical x Several models are under certification process. 'p 'A f 998 mm(39.29")(W)x 1,640 mm(64.57")(L)x 35 mm(1.38")(H) l, ,ght �4 Approx.18.7 kg(41.2 lbs) lar cells 60 cells in series(6 x10 matrix)with PERL technology(Hyundai cell,Made in Korea) Output cables 4 mm'(12AWG)cables with polarized weatherproof connectors, <, IEC certified(UL listed),Length 1.0 m(39.4") •Osnction box IP67,weatherproof,IEC certified(UL listed) , . + s�� �.x 3 bypass diodes to prevent power decrease by partial shade � : Front:Anti-reflective coating low-iron tempered glass,3.2 mm(0.126") "*' Encapsulant:EVA Back Sheet:Weatherproof film .......................----7 � ` j Clear anodized aluminum alloytype 6063(Black) _I •IEC 61215(Ed.2)and IEC 61730 by VDE _ ? •UL listed(UL 1703),Type 1 for Class A Fire Rating •' a + •Output power tolerance+3/-0% I _ �„, •ISO 9001:2000,ISO 14001:2004 and ISO 50001:2011 Certified t 4, t"'r { •OHSAS 18001:2007 Certified ' s •Advanced Mechanical Test(8,000 Pa)Passed(IEC) ,4), ' —� /Mechanical Load Test(40 lbs/ft')Passed(UL) L"k I �� Ammonia Corrosion Resistance Test Passed P l l 4 1 •IEC 61701(Salt Mist Corrosion Test)Passed r' � j •1st year:97% . •After 2nd year:0.7%annual degradation 80.2%for 25 years ' 3 ?� I 4 . t t .Please refer to the Hyundai Limited Warranty for more details. � ` _ I {1 ' 't7v x -v x Important Notice on Warranty `' tito.,-.,-e, ,, f c The warranties apply only to the PV modules with Hyundai Heavy Industries Co.,Ltds `°� �,, ;, r ;��-„=`' logo(shown below)and product serial number on it s i,,^^a. �, HYUNDAI c VL us, ' PV CYCLE 1m� , til C '` HEAVY INDUSTRIES Electrical Characteristics Multi-crystalline Type Nominal output(Pmpp) W 265 270 275 Voltage at Pmax(Vmpp) V 31.3 31.4 31.5 Current at Pmax(Impp) A 8.5 8.6 8.7 Open circuit voltage(Voc) V 37.9 38.0 38.2 Short circuit current(Isc) A 9.1 9.2 9.3 • Output tolerance % +3/-0 No.of cells&connections pcs 60 in series Cell type - 6"Multi-crystalline silicon with PERL technology(Hyundai cell,Made in Korea) Module efficiency % 16.2 165 16.8 Temperature coefficient of Pmpp %/K -0.41 -0.41 -0.41 Temperature coefficient of Voc %/K -0.32 -0.32 -0.32 Temperature coefficient of Ix %/K 0.039 0.039 0.039 XAll data at STC(Standard Test Conditions).Above data may be changed without prior notice I Mono-crystalline Type Nominal output(Pmpp) W 280 285 290 Voltage at Pmax(Vmpp) V 31.7 31.8 32.0 Current at Pmax(Impp) A 8.8 8.9 9.1 Open circuit voltage(Voc) V 38.5 38.7 38.8 Short circuit current(Isc) A 9.4 9.5 9.7 Output tolerance % +3/-0 No.of cells&connections pcs 60 in series Cell type - 6"Mono-crystalline silicon with PERL technology(Hyundai cell,Made in Korea) Module efficiency % 17.1 17.4 17.7 Temperature coefficient of Pmpp %/K -0.42 -0.42 -0.42 Temperature coefficient of Voc %/K -030 -0.30 -0.30 Temperature coefficient of Ix %/K 0.047 0.047 0.047 - t6All data at STC(Standard Test Conditions)Above data may be changed without prior notice. Module Diagram I (unit:mm,inch) I l-V Curves carrent[AI I iIIIIIlluIIIIIIIIIIIIIi ;It= . 1 w,� 5` llllulillnllllu111111 �` rH r TS(03� 3'MI1111111111111111111 190mm() 1+) mm ~ ILA3 1111111111111111111111111 ;m' & �&' ►�880LDTTHRU ;^ 111111111111111111111111 CONNECTORCONNECTORmrU ' i �'IIIIIIII1111111111111111i , 01lfMtw1015M25b33 M Illllllllllllllllllllilf �4600eND MARK DETAILS s tAeOW 111111111111111111111111 n i OROIJNDHOIE _bD R�4°) '_�8(0.71 11(0.43') > .._ -600W/m, a .111111111111111111111111 954(3756'I. v r, 30OWhn' r IIJIIlllhIIIIIUhIIIftI A C 998(39.39°) C 1253(9.961 Mara 1.0 0.0 t SECTION c{ 0 0 s 10 15 20 25 30 35 40 45 SO 9dm93B9 Installation Safety Guide Ie ; •Only qualified personnel should install or perform maintenance. ;>. "a � ,W4 -40-85°C •Be aware of dangerous high DC voltage. ;i DC 1,000V(IEC) •Do not damage or scratch the rear surface of the module. x DC 600 V(UL) •Do not handle or install modules when they are wet. is A (Printed Date:December 20151 Sales&Marketing �� no.rr onvPaPsr Oed Hyundai Bldg.,75,Yu1 ok-ro,Jon no- u,Seoul 03058,Korea �� HYUNDAI P'w e<otdonF5taer. y9 9 9 Tel:+82-2-746-4671,7635,8556 Fax:+82-2-746-7675 HEAVY INDUSTRIES