Loading...
Specifications (6) WINSIV Aftnd 5Wer f el M Sr20aV1354 N S 1 SHERMAN .r, LNGINEERING ii, A 3151 NE SANDY BLVD.,Sum: 100 PORTLAND,OR 97232 INC PHONE (503) 230-8876 . ..'....) ri-L_f_u-ni 1 -71—tr—u-71-__ SliaR.MANENGEIZERS.COM 1--------- Structural Calculations RECEIVED July 24, 2019 SEP 4 2019 CITY OF TIGARD Moreland Plan !,..°,PNi3„° B 1:4:5:-o4, UILDING DIVISION Lot 5, Canyon Court Tigard, OR `.d••, ..,\- 1,. `r- ai ... V i• — • I' 1.40 40 Prepared For: 0 10.\-2 P. SHEY;oc Suntel Design, Inc. 16865 Boones Ferry Rd. EXPIRES. 6/301 Lake Oswego, OR 97035 Subject Sheet No. Lateral: Loading LL1-LL3 Shearwalls LL4 Overturning LL5 r I MORELAND PLAN I Lateral Load LL I 7/24/19 1 . Loading 2014 OSSC 1 .1 Wind: Per ASCE 7-1 0 Basic Wind Speed= 120 Kzt = I.00 Exposure Category= B A = I.00 Building Height= 18.5 I = I.00 Roof Slope= 4 :12 = 18.4` _ Zone Pressure ASD LC ASD Pressure A 30.7 0.6 = 18.4 B -8.7 0.6 = -5.2 Use 5 psf at roof for MWFRS C 20.5 0.6 = 12.3 D -4.9 0.6 = -2.9 Use 5 psf at roof for MWFRS •End Zone Distance: Faye Ht(ft) 18.5 x 40% = 7.4 ft Bldg Width(ft) 28 x 10% = 2.8 ft Width x4%= I.I ft Bldg Length(ft) 40 x 10% = 4.0 ft Length'x4%= 1.6 ft Minimum= 2.8 ft Edge Strip= 3.0 ft (End Zone=2x Edge Strip) End Zone= 6.0 ft I.2 Seismic: Per 2014 OSSC Use Group= I Number of Stories= 2 <3 Simplified analysis per ASCE 7-10 S . = 0.7 R= 6.5 V = 1 .3R5d5 W = 0.140 W Roof W= 15.0 1 100 = 16.5 Walls = 8 8.0 ft 1/2 136 = 4.4 Partitions = 6 8.0 ft 1/2 66 = 2.1 >I 23.0 x 18 = 41.3 Floor W = 15 1008 = 1 5.1 Walls = 8 9.0 ft 1/2 126 + 4,4 = 9.0 Partitions = 6 9.0 ft 1/2 40 + 2.1 = 3.2 27.3 x 10 = 273 50.2 686 X 0.140 7.0 = Base Shear Distribution: Qzr = 686 X 413 = 4:4= 3.0 ()Fir 686 X 273 = 2.8 = 2.0 LL-Moreland-Canyou Court ds SHERMAN ENGINEERING, INC. 3151 NE Sandy Blvd Suite 100 Portland, OR 97232 WIND LOAD 2014 IBC/OSSC JOB: MORELAND PLAN Loading: SIDE/SIDE V1 V2 V3 V4 Roof Wall End Zone = 5 psf 18.4 psf Interior= 5 psf 12.3 psf End Zone Interior 1 y End Zone End Zone Length = 6 ft Roof Ht. 6 ft11• Diaph 1 width 40 ft Wall Ht. 8 ft Qn Ln Ln Diaph 2 width 40 ft Shear V1 V2 V3 V4 REACTION Line Condition load trib trib total load trib trib total load trib trib total load trib trib total Q ROOF width height width width height width width height width width height width psf ft ft ft psf ft ft ft psf ft ft ft psf ft ft _ ft kips 1 End Left 5 6 6 40 5 34 6 40 0.6 X Inter 5 6 0 40 5 0 6 40 5 34 0 40 5 6 0 40 0.0 2 End Right 5 34 6 40 5 6 6 40 0.6 Shear VI V2 V3 V4 REACTION Line Condition load trib trib total load trib trib total load trib trib total load trib trib total Q UPR FLR width height width width height width width height width width height width psf ft ft ft psf ft ft ft psf ft ft ft psf ft ft ft kips 1 End Left 18.4 6 4 40 12.3 34 4 40 1.1 X Inter 18.4 6 0 40 12.3 34 0 40 12.3 34 0 40 18.4 6 0 40 0.0 2 End Right 12.3 34 4 40 18.4 6 4 40 1.1 TOTAL UPPER FLOOR LOAD LINE ROOF UPR FLR TOTAL • 1 0.6 1.1 1.7 X 0.0 0.0 0.0 2 0.6 1.1 1.7 3.4 j; j N • SHERMAN ENGINEERING, INC. 3151 NE Sandy Blvd Suite 100 Portland, OR 97232 MAIN FLR Roof Wall End Zone= 5 psf 18.4 psf Interior= 5 psf 12.3 psf Wall Ht. 9 ft Diaph 1 width 36 ft Diaph 2 width 36 ft Shear V1 V2 V3 V4 REACTION Line Condition load trib trib total load trib trib total load trib trib total load trib trib total Q MAIN FLR width height width width height width width height width width height width psf ft ft ft psf ft ft ft psf ft ft ft psf ft ft ft kips 1 End Left 18.4 6 9 36 12.3 30 9 36 2.3 X Inter 18.4 6 0 36 12.3 30 0 36 12.3 30 0 36 18.4 6 0 36 0.0 2 End Right 12.3 30 9 36 18.4 6 9 36 2.3 4.6 i .._.v..._ \H i v } �� 1 Zai 4 / 0 _ 3 3 '22 \,/2, l`17-�L ( 1;5Q Z 1 :70V 14744-0 2 pLooe ''7 ,,soy, ; ( 0 . I 0 11-) IAB 1.8 it • OVERTURNING - FRONT BACK PROJECT LL 7/24/2019 GRID SHEAR DEAD DEAD DEAD LOAD LOAD NET LINE LEVEL LENGTH SHEAR/FT HEIGHT TRIG LOAD M,resist REDUCTION M,ot ABOVE UPLIFT LINE 2 V-2 3 0.142 8 4 15 0.56 WIND 3.4 0.00 I .02 Use MSTA36 V-1 1.83 0.775 6.25 7 15 0.26 WIND 8.9 0.00 4.76 Use HDUB LINE 2 V-2 3 0.125 8 4 15 0.56 SEISMIC 3.0 0.00 0.59 Use MSTA36 V-1 1.83 0.484 6.25 7 15 0.26 SEISMIC 5.5 0.00 2.94 Use STHD 14 7" OT-Moreland-Canyon Court.xls