Report 4, HAYDEN12480 SW 68th Ave. 13 ENGINEERS Tigard, Oregon 97223 Phone: 503-968-9994 STRUCTURAL I CIVIL Fax: 503-968-8444 Brett Trevor October 03, 2019 15270 SW 79th Ave Tigard, OR , 1'Na2ez Re: Clarification HCE Project #19121 15270 SW 79th Ave Tigard, OR Dear Mr. Trevor, It is acceptable to use a Simpson `HGA10' from the ridge beam to the 4x4 posts in lieu of the 'AC' cap specified on 1/S2.1 The omission of anchor bolts is acceptable in the sill plate under the new front door entry wall. If you have any questions, please do not hesitate to call. ��¢�a PROFFss� mac' 4'�C' ► NfiF o� 83248PE 'Q Sincerely, Hayden Consulting Engineers, Inc. �'9y Reco14 2°�� tiw`� ��rF(CA S �\� EXPIRES: 12/31/2020 By: dkori. .: By: 7 Aaron Schmalz Gabriella Miller, P.E. Structural Designer Principal Hayden Consulting Engineers, Inc. ,07kED PRQf .fie GIN � s�0 83248PEJ; f OREIN /-46) 14 , 20 � ��FC CA S • \�� EXPIRES: 12/31/2020 WALL FRAMING &SHT'G, PER PLAN P.T.2X BOTTOM PLATE RIPPED TO FIT STEM WIDTH W/%"0x8"EMBED AB'S@32"O/C SIMPSON 'JB28'HANGER TYP. Y2" EDGE NAILING • FLR.FRAMING 6 PER PLAN MIN \ � ���/\� 6"CONC.WALL W/(2) HORIZ. �`�\j\�` #4 CONT. (1) TOP&BOTT.+ \��� (1) #4@24"0/C& l'-0" #4 VERTS.@ 48"0/C WI MIN. 8"STND. HOOK INTO FTG. 4'-0" ALTERNATING. MAX. • PER 5 ,\\\\;\ \/\/\' \� PLAN CLR. \ --• • \j \ \ - 9/17/19 dili �L• AI SECTION S2.0 19121 - 15270 SW 79TH AVE ENTRY ADDITION - SHEETS.DWG SCALE: 1"=1'-0" BRETT TREVOR ADDITION BY AS DATE 09/17/19 HAYDEN 15270 SW 79TH AVE REV DATE ENGINEERS TIGARD, OREGON STRUCTURAL I CIVIL JOB NO 19121 (503) 968-9994 p (503) 968-8444 f SHEET 1 OF 1