Report 4, HAYDEN12480 SW 68th Ave.
13 ENGINEERS Tigard, Oregon 97223
Phone: 503-968-9994
STRUCTURAL I CIVIL Fax: 503-968-8444
Brett Trevor October 03, 2019
15270 SW 79th Ave
Tigard, OR , 1'Na2ez
Re: Clarification HCE Project #19121
15270 SW 79th Ave
Tigard, OR
Dear Mr. Trevor,
It is acceptable to use a Simpson `HGA10' from the ridge beam to the 4x4 posts in lieu
of the 'AC' cap specified on 1/S2.1
The omission of anchor bolts is acceptable in the sill plate under the new front door
entry wall.
If you have any questions, please do not hesitate to call. ��¢�a PROFFss�
mac' 4'�C' ► NfiF o�
83248PE 'Q
Sincerely,
Hayden Consulting Engineers, Inc. �'9y Reco14 2°�� tiw`�
��rF(CA S �\�
EXPIRES: 12/31/2020
By: dkori. .: By:
7
Aaron Schmalz Gabriella Miller, P.E.
Structural Designer Principal
Hayden Consulting Engineers, Inc.
,07kED PRQf
.fie GIN � s�0
83248PEJ;
f
OREIN
/-46) 14 , 20 �
��FC CA S • \��
EXPIRES: 12/31/2020
WALL FRAMING
&SHT'G, PER PLAN
P.T.2X BOTTOM
PLATE RIPPED TO FIT STEM WIDTH
W/%"0x8"EMBED AB'S@32"O/C
SIMPSON 'JB28'HANGER TYP.
Y2"
EDGE NAILING
• FLR.FRAMING
6 PER PLAN
MIN
\ � ���/\� 6"CONC.WALL W/(2) HORIZ.
�`�\j\�` #4 CONT. (1) TOP&BOTT.+
\��� (1) #4@24"0/C&
l'-0" #4 VERTS.@ 48"0/C WI
MIN. 8"STND. HOOK INTO FTG.
4'-0" ALTERNATING.
MAX. •
PER 5 ,\\\\;\ \/\/\' \�
PLAN CLR. \ --• • \j
\ \ - 9/17/19
dili �L•
AI SECTION
S2.0 19121 - 15270 SW 79TH AVE ENTRY ADDITION - SHEETS.DWG SCALE: 1"=1'-0"
BRETT TREVOR ADDITION BY AS DATE 09/17/19
HAYDEN 15270 SW 79TH AVE REV DATE
ENGINEERS TIGARD, OREGON
STRUCTURAL I CIVIL JOB NO 19121
(503) 968-9994 p (503) 968-8444 f SHEET 1 OF 1