Loading...
Plans (2) RECEIVED Building Plans for City of Tigard Building Permit Application SEP 11 2019 CITY OF TIGARD Customer: The Fountains at Summerfield condominiums HOA BUILDING DIVISION 15685 SW 116th Ave., #105 Tigard, OR 97224 Contact - Paul Brock, 858-212-9105, pbrock987Pgmail.com Contractor: Jon Erickson, 503-730-9220 ion.eveniobs( gmail.com CCB 162397 OFFICE COPY CITY OF TIGARD Scope of Work— Repair Decks REVIE 'ED FOR CODE COMPLIANCE • Replace perimeter joists with PT Approved: ] • Repair joist and soffit dry rot OTC: [ I Replace 42" guardrail and infill to comply with Permit#: • ac�l9" OQ Address: IBC multi-family code Suite#: ixq By Data q.. VALIDITY OF PERM i File Name: Fountains Deck Permit Plans REVISED.pptx THE ISSUANCE OF A PERMIT BASED ON CONSTRUCTION DOCUMENTS AND OTHER DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM REQUIRING THE CORRECTION OF ERRORS.OSSC 105.4 9/11/19 Fountains at Summerfield - Deck Building Plans 1 RSo-7 . 1., (-1 m.n a. Lettrt) Joc,d Typical Deck Construction and Size — 102 SF X114 e.c.jo( s < .__.__ > Brick Co 114.5" 15 x 11.5 "C�_ Imbedded 6x6 PT • n ri 4x4 PT Posts A < 2 x 8 PT blocking between joists attached with : — Three 16D 3-1/2"n HDG ><--->< Ref: 2014 Oregon Structural 43" 15" 56.5" Specialty Code–Table 2304.9.1-29 2"x8"Joists 16" OC Blocking supports Simpson Rim joist attached to Tension Ties DTT2Z. Two lateral joists with • / DTT2Z brackets required for -------->Three 16D 3-1/2"n HDG posts in this position. See Beam^' 6"x10" Simpson Wood Connection Ref: 2014 Oregon Connectors 2018-18 Deck Structural Specialty Tension Ties– page 337 Code–Table N 2304.9.1-29 ,-' House–Brick exterior • S ;ws p$011 L.VSd, 43" > Scale– 12"/increment V ■ ■ d"" 9/11/19 Fountains at Summerfield - Deck Building Plans 2 Water Penetration Remediation — Cross Section Posts—4x4 PT Flashing 2" x 3" L Resurfacing material 3/4" exterior plywood decking 0 E Co x N '--- Hardi-plank Fascia 9.25" x .25". Applied with exterior adhesive and secured with post bolts. Wicking protection for soffit provided by 'A" extension. Pre-paint before adding flashing 7 %" plywood soffit ' V Scale— 1" increment IIIIIMIIIIIIIIIIIIIII 11.11111111111111111111111 9/11/19 Fountains at Summerfield - Deck Building Plans 3 Guard Rail Post — Simpson Tension Ties Posts—4x4 PT Simpson DDT2Z Attach to lateral joist with 8 SDS 1.5" screws 1/2„ x 6" Machine Bolt DTT2Z supports 1800 lb. HDG with nuts and tension load. Meets IBC washers Code for multi-family deck 00 'o guardrails. x, E Refer to attached Simpson C catalog - Deck Tension Ties Lateral Joist page 337 Also refer to Simpson code- compliant Guardrail Post Connection bulletin T-C-GRDRLPST17 Scale— 1" increment 9/11/19 Fountains at Summerfield - Deck Building Plans 4 • Typical Guardrail and Infill Section — 50" max. between posts W.m .. Simpson Strong Drive A Wide Screw SDWS 4", 2 3/8"TL. Two per __ g x 4 TKC Cap Rail—Trex Railing 2 °etetz end,three in mid span 1" x 5.5" f, I " I attached to it ;1. 4 ,. �4 r Railing with . " exterior ',' � r i imp ,1 adhesive. 6 t ,! pt.:: n , } � r �� Z mss. ilh p 1 �, G 'Atv,„1",)''4 Ln to cri Vq 4 I Railing Support � A-4,10414104140 2 x 4 TKC . oa. I "t �. q oo Attached to a k ,° c� Railing and .t 0 ' Pe Y: Installation of Posts with I. �; �` balasters and rails ��° � per mfg installation adhesive and '' Tu F Simpson ra instructions. Strong Drive ,; "' Wide Screw SDWS 4", Railing Infill - Railing 2 x 4 TKC 2 3/8"TL. DecKorator aluminum V 2.75" space balaster 3/" x 32". • Spacing 3.75" DecKorator Scale 1" incrementsiX CodeCompliance Research Report iiiiIIIIIliii CCRR-0161 9/11/19 Fountains at Summerfield - Deck Building Plans 5 of 5