Permit (5) CITY OF TIGARD MASTER PERMIT
IN
.. ' COMMUNITY DEVELOPMENT
Permit#: MST2019 00401
13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 10/24/2019
T� " Parcel: 2S112CA06900
Jurisdiction: Tigard
Site address: 15365 SW 79TH AVE
Subdivision: ASHFORD OAKS Lot: 23
Project: LAVIGNE
Project Description: Solar photovoltaic system.
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $9,786.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0
0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0
Other Fixtures: 0
Drywell-Trench Drain: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0
Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All
Other: Y Other Description: Roof top PV system 9,75 kW Ecompasing: N
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
OTR SF VB R-3 0
Owner: Contractor:
LAVIGNE,EDWARD&DEBRA LIVING T DYNAMIC POWER INNOVATION LLC Required Items and Reports(Conditions)
15365 SW 79TH AVE 20345 SW PACIFIC HWY STE 103
TIGARD,OR 97224 SHERWOOD,OR 97140
PHONE: 503-740-6280 PHONE: 503-857-0412
FAX:
Total Fees: $357.19
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will
be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180
days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
952-001-0010 through
0 952-001-0090. Yo H. •btain a copy of the r - •r direct questions to OUNC by calling 503.232.1987• '! • . -,:.
Issued By: .go.1 • e Signature ,�.-
C.,i# 4175 by 7:00 a.m.for the next availabl- • •- ion date. .
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
$uilding Permit Application RECEIVEI '
Residential FOR OFFICE USE ONLY
Cl of Tigard
OCT 1 7 2019 Received l I! P
'� 13125 SW Hall Blvd.,Tigard,OR 97223 CITY
+TV PlanaReview U/ 1 L y / 6 To2(�g/ 64/Cr
�r't i i I.L'.- 1"0 !i' I#( A'� Other Pemut:
I1 Phone: 503.718.2439 Fax: 503.598.1960 ' •1}p ;�1 tt�n Date/B :
Inspection Line: 503.639.4175 BUILDING DJVi.�ION Date Ready/By: Juris: I l3 See Page 2 for
TIGARD //�/j,
Internet: www.tigard-or.gov tified/Method:( /j/, �i Supplemental Information
TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING
❑New construction ❑Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
®Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the
` CATEGORY OF CONSTRLC�
,1 work indicated on this application.
® 1-and 2-family dwelling ❑Commercial/industrial Valuation: $9,786
Number of bedrooms:
1:3Accessory building ❑Multi-family
❑Master builder 0 Other: Number of bathrooms:
t , .
iirt 'iia " v0 rC ORMATION AND LOCATION Total number of floors:
Job site address: 15365 SW 79"'Ave New dwelling area: square feet
City/State/ZIP:Tigard,OR 97224 Garage/carport area: square feet
Suite/bldg./apt.no.: Project name:LaVigne Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
Other structure area: 544 square feet
hU1RED DATA:COMMERCIAL-USE CHECKLIST
Subdivision: Lot no.: Permit fees*are based on the value of the work performed.
Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all
equipment,materials,labor,overhead,and the profit for the
DESCRIPTION O WORD work indicated on this application.
Install 9.75kW rooftop solar system Valuation: $
Existing building area: square feet
New building area: square feet
® PROPERTY OWNER ❑ TENANT Number of stories:
Name:Ed&Debra LaVigne Type of construction:
Address:15365 SW 79th Ave. Occupancy groups:
City/State/ZIP:Tigard,OR 97224 Existing:
Phone:(503)740-6280 Fax:( ) New:
® APPLICANT ' 0 CONTACT PERSON BUILDING PERMIT FEES*4: ^
(Please refer to fee schedule) f
Business name:DPI Solar
Structural plan review fee(or deposit):
Contact name:Erik Beeman
Address:20345 SW Pacific Hwy,Suite 103 FLS plan review fee(if applicable):
City/State/ZIP:Sherwood,OR 97140 Total fees due upon application:
Phone:(971)990-1924 Fax::( ) 1t
Amount received.
l' iE-mail:erik@dpisolar.com tI e OVOLTAIC SOLAR�l SYSTFM FEES*
Commercial and residential prescriptive installation of
,,e,,.a roof-top mounted Photo Voltaic Solar Panel System.
Business name:DPI Solar Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address:20345 SW Pacific Hwy,Suite 103 Solar Installation Specialty Code checklist.
City/State/ZIP:Sherwood,OR 97140 Permit Fee(includes plan review $180.00
and administrative fees):
Phone:(503)857-0099 Fax:( ) State surcharge(12%of permit fee): $21.60
CCB lic.:185494 Total fee due upon application: $201.60
Authorized signa This permit application expires if a permit is not obtained
within 180 days after it has been accepted as complete.
Print name:Erik eeman Date: 10/16/19 *Fee methodology set by Tri-County Building Industry
Service Board.
I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB)
,
RECEIVED
Electrical Permit Application ��T I Olt 00'1( I,I'sl:0N1,1
:�. 2019
City of Tigard Receivedriff!
IMEZI
I 13125 SW Hall Blvd.,Tigard,OR 97223 r T GARI� Dan : / /
g ',;,�c)s . ,. Plan Review Related Permit#:
Phone: 503.718.2439 Fax: 503.598.1960 o L®) G®AVL '• Dates
Inspection Line: 503.639.4175 Ready Date/By: Juris: El See Page 2 for
Internet: www.tigard-or.gov Notitied/Method: Supplemental Information
._.. ."
_... ,-.,- G. 15M i'x _„ -7777:5;;;, k,_t6. w VP7 - -7.377
te7.7.77.710,r
r =
_
El New construction
®Addition/alteration/replacement Please check all that apply(submit 2 sets of plans wlitems checked):
El Service or feeder 400 amps or more 0 Building over three stories.
❑Demolition 0 Other: where the available fault current 0 Marinas and boatyards.
0,;, ? 5 int,,,S jt,' s,6 tai k,1l10, ;i:.^' ''j „.", exceeds 10,000 amps at 150 volts or 0 Floating buildings.
® 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural
amps for all other installations. buildings.
❑Multi-family D Master builder 0 Other: 0 Fire pump. 0 Installation of 150 KVA or
w-'r s "; �_'1��V�ifa �� :' K =: ,.h9 Er• �� '`sy�� = ..: ❑Emergency system, larger separately
derived
❑
Addition of new motor load of system.
Job#: Job site address:15365 SW 79th Ave 100HP or more. ❑"A","E","1-2","1-3",
City/State/ZIP:Tigard,OR 97224
El Six or more residential units. occupancy.
0 Health-care facilities. 0 Recreational vehicle parks.
Suite/bldg./apt.#: I Project name:LaVigne 0 Hazardous locations. 0 Supply voltage for more than
❑Service or feeder 600 amps or more. 600 volts nominal.
Cross street/directions to job site: t, q " " 1
Description Qty. Each Total
New residential single-or multi-family dwelling unit.
Subdivision: I Lot#: Includes attached garage.
Tax map/parcel#: 1,000 sq.ft.or less 168.54 4
Ea add'I 500 sq.ft.or portion 33.92 1
IMIIIIIIIIIIMMIEMIVIt_ +_t'0 ' 0) , =' �. Limited energy,residential
75.00 2
Install 9.75kW prescriptive rooftop solar array (with above sq.ft.)
Limited energy,multi-family 75.00 2
residential(with above sq.ft.)
Renewable Energy ® See Page 2 133.56
- 'r d,7i"•`iii' AI".m•, -t ..• - ` q Services or feeders installation,alteration,and/or relocation
Name:Ed&Debra LaVigne 200 amps or less 100.70 2
Address:15365 SW 79th Ave 201 amps to 400 amps 133.56 2
401 amps to 600 amps 200.34 2
City/State/ZIP:Tigard,OR 97224 601 amps to 1,000 amps 301.04 2
Phone:(503)740-6280 I Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email: relocation
Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2
Owner signature: Date: 401 amps to 599 amps 168.54 2
; :.• ,ill „a ( tAJ a ;: , : 9-, �: ,,Q spa Branch circuits—new,alteration,or extension,p,erpanel
.. - ,i:, �( " ' - "` A.Fee for branch circuits with
Business name:DPI Solar above service or feeder fee,
each branch circuit 7'42 2
Contact name:Erik Beeman B.Fee for branch circuits without
Address:20345 SW Pacific HwySuite 103 service or feeder fee,first
branch circuit 56,18 2
City/State/ZIP:Sherwood,OR 97140 Each add'I branch circuit 7.42 2
Miscellaneous(service or feeder not included)
Phone:(971)990-1924 I Fax: :( ) Each manufactured or modular 67.84 2
erik@dpisolar.com dwelling,service and/or feeder
Email:
@dp Reconnect only 67,84 2
• .;?' W •€,, „ ' '7.7z,&:p .. ,.k . Pump or irrigation circle 67.84 2
Business name:DPI Solar Sign or outline lighting 67.84 2
Address:20345 SW Pacific HwySuite 103 Signall, len or!extension. 0 See Page 2 2
panel,alteration,or extension.
City/State/ZIPSherwood,OR 97140 Each additional inspection over allowable in any of the above
Additional inspection(1 hr min) 66.25/hr
Investigation(1 he min} I 90.00/hr
Phone:(503)857-0099 Fax:( ) i
Email:erik@dpisolar.com Industrial plant(1 hr min) 78.18/hr
Inspections for which no fee is 90.00/hr
CCB Lie.: 185494 Electrical Lie.: 22895J Suprv.Lie.: CLR34 sgectfically listed(%:hr mint 1
Suprv.Electrician signature,required: - "• � � ti x Subtotal: 133.56
Print name: Josh Kopczynsky Date: 10/16/19 0 Plan Review Required(25%of permit fee):
State surcharge(12%of permit fee): 16.03
Authorized signature: TOTAL PERMIT FEE: 149.59
This permit application expires if a permit is not obtained within 180
Print name: Erik Beeman Date: 10/16/19 days after it has been accepted as complete.
' Number of inspections allowed per permit.
t:\Building\Pemtits\ELC_PemutApp_ELR_ERE.dot Rev 06/17/2015 440-46151'01/CIS/COM/WEB
i
Electrical Permit ApplicationF1s FOR OFFICE USE ONLY
Received
City of Tigard p C T 1 7 2019 Permit#:
Da[eB
13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review
I C1TY Phone: 503.718.2439 Fax: 503.598.1960 O;TIGARO DateB Related Permit 4:
Inspection Line: 503.639.4175 BUILDING Reaiy Date/By: Jurist H See Page 2 for
IIt,ARI� Internet: www.tigard-or.gov Q+ I Notified Method: Supplemental Information
TYPE OF W�f (� L LAN REVI v. ,� •, s
❑New construction ®Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked):
❑Service or feeder 400 amps or more ❑Building over three stories.
❑Demolition ❑Other: where the available fault current ❑Marinas and boatyards.
- CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings.
Z 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building less to ground,or exceeds 14,000 ❑Commercial-use agricultural
amps for all other installations. buildings.
0 Multi-family 0 Master builder 0 Other: ❑Fire pump. 0 Installation of 150 KVA or
7
JOB SITE INP!Jr, Emergencyof system.
oewmotor load of lazgersystem.separately derived
Job#: Job site address:15365 SW 79th Ave ❑Ad
100HPHP o or more. ❑"A","E","I-2","1-3",
City/State/ZIP:Tigard,OR 97224 ❑Six or more residential units. Recreational vehicle arks.
❑Health-caze facilities. ❑ P
Suite/bldg./apt.#: Project name:LaVigne ❑Hazardous locations. 0 Supply voltage for more than
❑Service or feeder 600 amps or more. 600 volts nominal.
Cross street/directions to job site: a 1
Description Qty. Each Total *
New residential single-or multi-family dwelling unit.
Subdivision: Lot#: Includes attached garage.
1,000 sq.ft.or less 168.54 4
Tax map/parcel#: Ea.add'l 500 sq.ft.or portion 33.92 1
DESCRIPTION OF WORK N Limited energy,residential
Install 9.75kW prescriptive rooftop solar array (with above sq.ft.) 75.00 2
Limited energy,multi-family 75.00 2
residential(with above sq.ft.)
Renewable Energy -i See Page 2 133.56
0 PROPERTY O", ,k 0 TENANT 1 . mLw,: Services or feeders installation,alteration,and/or relocation
Name:Ed&Debra LaVigne 200 amps or less 100.70 2
Address:15365 SW 79th Ave 201 amps to 400 amps 133.56 2
401 amps to 600 amps 200.34 2
City/State/ZIP:Tigard,OR 97224 601 amps to 1,000 amps 301.04 2
Phone:(503)740-6280 Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email:
relocation
Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2
Owner signature: Date: 401 amps to 599 amps 168.54 2
® A 'LIC '; 0 CONTACT PERSON Branch circuits—new,alteration,or extension,per panel
��' i.0A.Fee for branch circuits with
Business name:DPI Solar above service or feeder fee, 7.42 2
each branch circuit
Contact name:Erik Beeman B.Fee for branch circuits without
service or feeder fee,first
Address:20345 SW Pacific Hwy Suite 103 branch circuit 56.18 2
City/State/ZIP:Sherwood,OR 97140 Each add'1 branch circuit 7.42 2
Miscellaneous(service or feeder not included)
Phone:(971)990-1924 Fax: :( ) Each manufactured or modulaz
dwelling,service and or feeder 67.84 2
Email:erik@dpisolar.com Reconnect only 67.84 2
—777.377.7i1:7-2Z-3721':J I Pump or irrigation circle 67.84 2
Business name:DPI Solar Sign or outline lighting 67.84 2
Address:20345 SW Pacific HwySuite 103 Signal circuit(s)or limited-energy 0 See Page 2 2
panel,alteration,or extension.
City/State/ZIP:Sherwood,OR 97140 Each additional inspection over allowable in any of the above
Additional inspection(1 hr min) 66.25/hr
Phone:(503)857-0099 Fax:( ) Investigation(1 hr min) 90.00/hr
Email:erik@dpisolar.com Industrial plant(1 hr min) 78.18/hr
Inspections for which no fee is 90.00/hr
CCB Lic.: 185494 Electrical Lic.: 22895J Suprv.Lic.: CLR34 specifically listed(Yz hr mm)
ELECTRICAL PERMIT FE4v,p
Suprv.Electrician signature,required: Subtotal: 133.56
Print name: Josh Kopczynsky Date: 10/16/19 0 Plan Review Required(25%of permit fee):
State surcharge(12%of permit fee): 16.03
Authorized signature: TOTAL PERMIT FEE: 149.59
This permit application expires if a permit is not obtained within 180
Print name: Erik Beeman Date: 10/16/19 days after it has been accepted as complete.
* Number of inspections allowed per permit.
I:\Building\Permits'ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(11/05/COM/WEB
Electrical Permit Application—City of Tigard •
Page 2—Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
RESIDENTIAL WORK ONLY: FEE SCHEDULE 11
Description
Fee for all residential s 3'stems combined: $75.00 Qty. Each Total I
'•
Renewable electrical energy systems:
Check Type of Work Involved: s kva or less 100.70 2
5.01 to 15 kva 1 133.56 133.56 2
❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
❑ Burglar Alarm 25.01 to 50 kva 301.04 2
50.01 to 100 kva 552.26 2
❑ Garage Door Opener* >100 kva(fee in accordance 552.26 2
with OAR 918-309-0040)
❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System* Each additional kva over 25 7.42 3
❑ Vacuum Systems* >100 kva—no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
❑ Other: Each additional inspection is 66.25/hr 1
charged at an hourly(1 hr min)
Inspections for which no fee is 90.00/hr
specifically listed(%hr min)
COMMERCIAL WORK ONLY: ELECTRIC_ `as
Subtotal(Enter on Page 1):
Fee for each commercial system: $75.00
Number of inspections allowed per permit.
(SEE OAR 918-309-0000)
Check Type of Work Involved:
❑ Audio and Stereo Systems
❑ Boiler Controls
❑ Clock Systems
❑ Data Telecommunication Installation
❑ Fire Alarm Installation
❑ HVAC
❑ Instrumentation
❑ Intercom and Paging Systems
❑ Landscape Irrigation Control*
❑ Medical
❑ Nurse Calls
❑ Outdoor Landscape Lighting*
❑ Protective Signaling
❑ Other:
Total number of commercial systems: _
*No licenses are required. Licenses are required for all
other installations
I:\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015
Cityof Tigard
RECEIVETh
g
q Building Division OCT 17 2019
CITY OF• 13125 SW Hall Blvd,Tigard, OR 97223 BUILDING p Vi3i3N
Phone: 503.718.2439 Fax: 503.598.1960
T I GA R D Inspection Line: 503.639.4175
www.tigard-or.gov
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 15365 SW 79th Ave.
City: Tigard, OR Zip: 97224
Owner's Name: Ed&Debi LaVigne Date: 10/17/19
Contractor's Name: DPI Solar CCB #: 185494
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? 171 No OSSC or ORSC for
design requirements.
Wind Exposure Is the wind exposure Yes If"Yes", qualifies for
"C"or less? P1 No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes ❑ Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
If"Yes", qualifies for
structures other than
® Yes the prescriptive path.
above
❑ No
1
I:Building/Forms/PhotoVoltaic-Checkl ist02-01-11.docx
I
Is the construction
material wood and does Yes
Type of the construction qualify If"Yes", qualifies for
ConstructionNo the prescriptive path.
as "conventional light
frame" construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. ElYes If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. If"Yes", qualifies for
Yes the prescriptive path.
II No
Is the combined weight 171 Yes
of the PV modules and If"Yes", qualifies for
racking less than or E No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
21
layout in accordance Yes
with Section 305.4(3) of If"Yes", qualifies for
the 2010 Oregon Solar ❑ No the prescriptive path.
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max.two layers the prescriptive path.
® of composition
shingle.
Is the roof mounted ® Yes
Connections of solar assembly
the solar assembly connected to roof If"Yes", qualifies for
❑ No the prescriptive path.
to the roof framing or blocking
directly?
2
I:Building/Forms/PhotoVoltaic-Checklist02-01-11.docx
K
Is the gauge 26 or less? ElYes If"Yes", qualifies for
❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inches Maximum 60 inches inches,qualifies for the
standing seam prescriptive path.
metalanels If the width of the panel
P Width of roofing is less than 18 inches,
panels? 18 inches or less qualifies for the
inches prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? El Yes the prescriptive path.
❑ No
•
Is the roof decking of
WSP min. '/2"thickness, El Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12" o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the topof the If"Yes", qualifies for
21 g
Yes
solar modules module to the roof the prescriptive path.
surface. 0 No
3
I:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing(rafter size,type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer:Hanwha
Model Number:Hanwha Tuxedo DUO G5 325W
Listing Agency:UL
4
I:Building/Forms/PhotoVoltaic-Checklist02-01-11.docx
FOR OFFICE USE ONLY–SITE ADDRESS:
This form is recognized by most building departments in the Tri-County area for transmitting information.
Please complete this form when submitting information for plan review responses and revisions.
This form and the information it provides helps the review process and response to your project.
City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT
!I Transmittal Letter
ra GA R n 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439• w«w.tigard-or &co.
TO: DATE RECEIVED:
DEPT: BUILDING DIVISION 4"It- .
OCT 2 4 2019
FROM: {-,ri k Beeman Y 1 1-10,A5:,:
COMPANY: DPI SE_ Ullt ! Lam: °'
PHONE: 9T1 t .9c1c. !qac By. ,5.
RE: l59)(s) 1,6 i Atkie,. /77757---df- 7–CJ`Z)l
(Site Address) (Permit )
I ()3J .
(Project name or subdivision name and lot number) i
ATTACHED ARE THE FOLLOWING ITEMS:
Copies: Description: Copies 0 1 escription:
Additional set(s)of plans. Revisions: kiew Sf)Inr in kl:v;s,'► luR)
Cross section(s) and details. /- , Wall bracing and/or lateral analysis.
Floor/roof framing. /AEI .1 Basement and retaining walls.
Beam calculations. - Engineer's calculations.
Other(explain): V
REMARKS: l\Affiae matrtu f ac*.r-,o( i jay e nakrrlge,
/
// FOR OFFICE USE ONLY
Routed to Permit Technic an. Date: Jo— 2.,y – 19 Initials:
Fees Due: ❑Yes No Fee Description: Amount Du .
,, $
�, $
/ $
Special 1/
Instr�uions:
' (-
yR fintwPermit(per PE): 0Yes No ❑Done
�� licant Notified: fr
_ Date: /�1hm/,, Initials: .. -r,
1:\Building\Forms\TransmittalLetter-Revisions 061316.doc