Loading...
Plans (6) T2or.9_ 6c) 3 G I • T N Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND Ihm i BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC. Delete Line '! ��\��7 en..XXX-XX GREEN LINES=INTERLEVEL CONECTIONS/SUPPLY. ) O c�i 1 MAXIMUM SPACING(TVP) BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. i Add Line SPRINKLER MODEL(TYP) g a MAXI U MSPL TIGARD —K — =1/2"PIPE SIZE 6 (TYP) Cr r-a-t! �><� =3/4"PIPE SIZE �'�°u, Add Tee -,- .. =1"PIPE SIZE O N Add Elbow A n,In.)N'(:Cl [ —u— = 1-1/4"PIPE SIZE N�°'z 1 C,_.lditionally Approved [ ] Q W Iwo V v u Z 2 Add Coupling J, [ ] 15"4"8" 5 ? F See Letter to: Follow o RECEIVED Add Head 1 �p,]� , Attached [ I �� I V S p.1.5 �\ _' 4 �. W q m txriaQW Permit Number: �1'IST901'I 0 0 Delete Head X Address: /41/S7 S W 16'► 4% o 5 ° =z�p� By: T� a 1 SEP 2 3 2019 % ag ��W Move Head C A e.-61 Date: •—26—` (�? = a p m p d Note:All revisions must be rev Uponor CITY OF TIGARD s°6o'a 02w 1 Multipurpose Table F002-1 .. -��.. I r 0 CC S o��5 � f� BUILDING DIVISION= g„ Y r o °gym, g purpose Fire Safety Systems Wgoa$81ega The Uponor Residential Fre Safety System is a residential fire protections system instated in combination with the cold side of the domestic potable water system. Only licensed contractors trained by Uponor can install this Zi' 4 z 6 t Z e 3 system. gIIIZ-°�660§/ sP MB p ° TF V What to do H Changes are Required °� c e If any features or obstructions require the addition or deletion of sprinkler am;F g 4Q 2 9�m 6 ~ heads,or significant relocation of sprinkler heads,contact the Uponor Design - - - - Department to determine if observed changes require a redesign gg ®Qz (� (888.594.7726). Woil I I grd�m l i g i,g ° o �sl MOST HYDRAULICALLY REMOTE HEADS 11 8 6 8'm o o.o_ •R $ O HEAD# GPM PRESSURE REQ'D AT STREET 8'�P o o q I 1 HEAD H.3 13 28.52 T.12 T.121� 2HEAD H.9&H.6 26 43.3 r-—{ s=pa oog� _ iihn 8i on, ii LF SENJU Model RC-RES Residential Hat Concealed Pendent SS8464 r AQUAPEX INTERLEVEL / I r AQUAPFO INTERLEVEL I K=4.9,162P,7 16"Orifice,Maximum Spacing 16'x16' CONNECTIONS FROM LOWER CONNECTIONS FROM LOWER ® - / P 9 FLOOR TO MIDDLE FLOOR FLOOR TO MIDDLE FLOOR RC-RES-16 Sprinkler head demand: 13 gpm @ 7.04 N . I rxd / �I LF SENJU Model RC-RES175 Residential Flat Concealed Pendent SS8464 \\�',�'/ ,lite �� 0 - - - 1 K=4.9,175F°,7/16"Orifice,Maximum Spacing 14'x14' \�l iti RC-RES-14-175 Sprinkler head demand: 13 gpm @ 7.04 -. I I \ \ �C FI T.24 \ \ T.24 T.27 H.7 H.7 T.27 r/ \\T,28 RES-1 RC-RES-116 T.28 CO i ci v T.30 ,a>. a T.30 Y f 0 17 \ i � 29 T.2F e LuIN'=q N U Ise el` Q- ,y ‹017,F.1,:: a — -co: v= W Y w z €tig° CURRENT STATIC EXTERIOR WALL T I— d WATER PRESSURE ELEV.109' Ce a I =TN °°'2 °' STATIC: 55psi LL u < n N of 1-1/4"AQUAPEX j ru (111 0 TO SYSTEM 5.1 TO HOT WATER HEATER zl 5 1"WATER METER O < O o'f '. rc STANDARD LOSS PER NFPA 13D ELEV 104 , 6•I''' ' a A� Ir., (3PSI LOSS FLOWING 26GPM) / • ¢ Q P o,i. =I, ---1-1/4"FULL PORT 1 LOWER FLOOR 2 LOWER FLOOR — MIRROR cc ==mnnl oo, ' BALL VALVE W O O F100 1/4n = 11_011 F100 1/411 = 11_011 Q 3 mid ! m Sllt MTR I—I =V F F rx r ra p!s a I ELEV-100'! ELEV=100' o 0 p{ O �5 E.< An� Ar Ar OUG®Lir _ • 1"METER SHEET DESCRIPTION 35'OF 100'OF LOWER FLOOR 8 1"COPPER-K 1-1/2"AQUAPEX a 3 WATER SERVICE DETAIL 5 0 5 15 SHEET NUMBER F100 NTS 1/4•-v-o" ' © UPONOR - CONFIDENTIAL r Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND r BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). Y Delete Line CI XXX-XX GREEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. O I } f BLACK LINES SP PINK S ZE HEAD TO SPRINKLER HEAD. -z -- I MAXIMUM SPACING(TYP) W g o Ado Line --- ---- -- -- --- SPRINKLER MODEL((YP) :x: =3/4°PIPE SIZE a m®u HEAD SYMBOL(TVP) ut Add Tee =1"PIPE SIZE Ell) � v I _ —F— =1-1/4"PIPE SIZE W w o 11•3''viz Add Elbow >�'O z C,np1�� Hfiaw� Add Coupling 1- o a.ei 3 WNr =Wm O,n!o-W3 Add Head "J �'CJ'� < Delete Head " °zi m 52 6Move Head Q116$g8IgiligtiZegr Note:All revisions must be reviewed by Uponor ,t Table F002-1 �1 6 e6 � R l i a Z , Multipurpose Fire Safety Systems n ✓ zE°�m< fuw5 CCo The Uponor Residential Flre Safety System is a residential fire protecclons 71 u u ' 5 6 o$op 1 g l system Installed in combination with the cold side of the domestic potable IU a 1 a G S ; 5y, , system. Y Y Uponor -. _. --- - water stem. Onl licensed contractors trained b U nor can Install this d zoh°CC c�t�F� °°� ° F system. I _. _ -__- liz What to do If Changes are Required ((n�g i l o a 2 u If any features or obstructions require the addition or deletion of sprinkler I rl® °tiz ,zj ci o �"y heads,or significant relocation of sprinkler heads,contact the Uponor Design .,�; m r ra b 8 Department to determine if observed changes require a redesign yg z c F 6 ° yry (888.594.7726). � g/is°g ��9g�o5� �'FIREPLACE i_—'.-- o � �so �o Ft H.2 H.2fl °°i;611i$1:1� RC-RES-16 FIREPLACE RC-RES-16 , , ,,i,,,„,,,.,„., �, T.11I� - khi , � I - 1 F.3 F.2 F.2- F.3 N 1"AQUAPEX INTERLEVEL I V AQUAPEX INTERLEVEL V AQUAPEX INTERLEVEL 11•AQUAPEX INTERLEVEL CONNECTIONS FROM LOWER, _ .'CONNECTIONS FROM MIDDLE CONNECTIONS FROM LOWER - _ CONNECRONS FROM MIDDLE FLOOR TO MIDDLE FLOOR \\ - - - j %/ FLOOR TO UPPER FLOOR FLOOR TO MIDDLE FLOOR �\ \ RC-n H.5S-16 F.5 5 __ ,_-_1-2 FLOOR TO UPPER FLOOR ra �� H5 H.5 F.5- \ \ T.16 G T.18 // T.18 'I"1f �q ...-A \I N I I „....-- ----- A ii k -F....64:, / c� T. \�, F T.20 oo 1 F.7 .F.2�2_ �l_ T.26 T.26 T.25 T,22 F.7 f oY.1 r•4 y F N O p Ia N p �. H.8 e m• F I - a,(a'J�mF ab�' R - ES 1$ .Y T_ T.3 T.32t3 A' T.31r,20 T.33 I o .. _ W N a V. DW LJ.J8U1. �0 as - i o Ce ce E Q O g$5 ' 1 MIDDLE FLOOR 2 MIDDLE FLOOR - MIRROR Q o oY ' F101 1/4" = 11_0" F101 1/4" = 11—O" (f)) Cal I1 m o. i g R = m 1 l K= j O U V 1 o SHEET DESCRIPTION MIDDLE FLOOR 'a SHEET NUMBER 5 0 _ o_s 15 3 I 1/4"=1'-0" © UPONOR - CONFIDENTIAL ' F101 S ily Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND i _. BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC. f s Delete Une - -- �XXX-XX GREEN LINES=INTERLEVEL CONN,CTIONS/SUPPLY. ) .] } BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. O o MAXIMUM SPACING(TVP) ;.-!7`1 .r z Add Line -'-- - - - SPRINKLER MODEL(TYP) .s� =1/2"PIPE SIZE S s HEAD SYMBOL(TSP) �z� =3/4"PIPE SIZE a$ ° Add Tee �I= =1"PIPE SIZE O �rP:u� Aad Elbow - r_IF =1-1/4"PIPE SIZE u t W N QM 2Nz Add Coupling H-1 M i v i 0 3 oh �- m m Add Head '4„I4. -CJSCvIN=3 Delete Head 0- < d PEOVIRgOgt Move Mead Cj O- �o����g����$ Note:All revisions must be reviewed by Uponor g aoaa� bIC3e Table Systems - t:z Multipurpose Fire Safety Systems o The Uponor Residential Fire Safety System Is a residential fire protections - LOW } W m o system Installed In combination with the cold side of the domestic potable ROOF Ce __ ��- (BELOW) _—� -_ water system. Only licensed contractors trained by Uponor can Install this --- _ F _ d system. - 1 --_ -- -- — --, z SS INS I -_ M 6Z 2 m �J YYhat to do it Changes are Required _- L V, < a i g b 1,3 M R If any features or obstructions require the addition or deletion of sprinkler o q heads,or significant relocation of sprinkler heads,contact the Uponor Design 1 Department to determine if observed changes require a redesignRPN C F a m s, yy s5 (888.594.7726). 12pzQ � '�6Q 5 y o H.1 1,m , a - H.1 RC- S-16 �I o i RC-RES-16 g ohm 085,%% � ,11� � r x r a o ft I i9 g4: (I� � lo. i, l' VI I I dz � 5 a 0 & �, T.10 ` iii +�� T.10 gOE,g s3 iori m rr ti -, i� b SD/CM Mr02 F.1 T.13 :� 14-3- I•AQUAPEx INTERLEVEL ,(--' I T.13 F.1 ... _ RC-RES-1 —c T,14 i ' FLOOR TO UPPER FLOOR INTERLEVEL i�I CONNECTIONS FROM MIDDLE T.14 H 4 ,j•FLOOR TO UPPER FLOOR _ CONNECTIONS FROM MIDDLE a F.4cl RC-RES-14-175/ H.4 c F.4 I T.17 T.17 j 6 I - ,- .19 T.19 SRC-RES-16 H.6 9 �,.� I I / I F 0. Pi Io g m in x T.23 T.23 I o$ b I. Lu =�a �" H.911 U 13stg5 a LJL1J is PC-RES-16 RC-RES-16 IC z Pe LLJ 0 6 p =ei m W 8884e0"0' a_.: im gCe ccE o ryI E 2I o UPPER FLOOR 2 UPPER FLOOR — MIRROR Q 0 ! NILO of F102 1/4" = 11-Qn F102 1/4" = 11_On C!) E}m ip I Ce I—F-.., O V z SHEET DESCRIPTION n UPPER FLOOR po' q m SHEET NUMBER s 0 5 15 3 e lieI. © UPONOR - CONFIDENTIAL Fi 12 Senju RC-RES:Open Web Truss/TJI Construction Insulation Recommendations See General Notes 8.2.5.7 for Architectural A TM In areas subject to freezing,care should be taken in unheated attic spaces m AquaSAFETM GENERAL NOTES: ProPEX LF Brass Flre to cover UponorAquaPbX tubing completely with insulation. Insulation Feature Requirements Z Sprinkler Adapter Tee should follow the guidelines of the insulation manufacturer. See Uponor - - - - % E 0 Maybes Fire Sprinkler Adapter Document"Uponor AquaSAFE Attic Insulation Guldlines"for attic 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2016 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM Blocking ` j 0 O SECTION 3.3.11.3. Required.If Push-on Nut installation guidelines(Provided In Contractors Documents package or online s 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON Blocking is Used, - 1 S'f Min. at www.Uponorpro.com). a.,z Use The 2 Top 11/Z"Max. THIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND , Planter Box Window,Bay Window or Similar Feature. o.n S p Screw Holes. { ' e°etom aMa mnmg Extreme Temperature Installations UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. If no additinal floor area is created No Additional Sprinkler V Required. R'u Becket[a Face N Truss Q m�j �_� AquaSAFE Residential Flre Safety Systems are often installed in attics or 0 N 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE Fire Sprinkler Adapter LLL - other areas exposed to temperature extremes of heat and/or cold. Follow 8'-0"or less a RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE Mounting Bracket `_-� the recommended extreme weather installation Instructions to Isolate and / h;s.w 0 PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE protect system components from extreme temperatures. Because this RC-RES-16® w d u,z SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE • , system also delivers domestic cold water directly to plumbing fixtures, 9'-0"or less yJ ^y SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. 3-A 10 x 1/2" Uponor highly recommends that you protect the tubing with adequate / x 31 w Full Cou I insulation in warm weather areas to minimize heating of the cold water % $ e w o 3 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH Thread S rews 'U supply. • o g o m w NFPA 13D 2016 EDITION. In Botto Holes 5. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE NOT PERMITTED TO USE ANTI-FREEZE. \ Installation methods include,but are not limited to: 40.-.- -.. ..-• O m H w 3 �/� • Tenting over the fire sprinkler piping. 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR Lead-FreFla[J'°� • • Additional layers of batt insulation. If additional floor area is created.Cannot exceed 18 ft',be more than 2'-0" 1 DAMAGED MUST BE REPLACED. Conceal Sen1u -Concealed Flat • Increased of blown-in insulation. deep,more than 9'-0"wide and be with in the coverage area of the a Sprinkler Head Cover Plate depthsprinkler.No Additional Sprinkler Is Required. 61 12,4t9 z 204 . 7. WATER SHUT OFF VALVE IS NOT PERMITTED THAT ISOLATES THE SPRINKLER SYSTEM. Caution: If you will be installing spray foam insulation,make sure to �i q F 4,g_V l'9 protect all components during application.Consult with the spray foam 6 b p o`r3 m 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. Senju RC-RES:Traditional Wood Framing Construction manufacturer to ensure compatibility with all products before application. NFPA 13D Table 7.5.5.3 Distances From ,9.6WIRE m °a Heat Sources ° w sk7R �I 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;'WARNING,THE Consultation with local building officials is encouraged to ensure compliance @z� Q; WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND - - o 4 m H 6 U C E Qy} ' PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR ProPEX LP Brass Fire with local huildinq codes. a Are Sprinkler Adapter Ordinary Intermediate 5= 0 5 y AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, Sprinkler Adapter Tee o p Heat Source Temp. Temp.FILar z 9r x F:3 `Push-on Nut 135°-170° 175•-225° °E 2 R o WITHOUT ESYSTEMS AND IRE RK SHUT OFF VALVAS, E SHALL NOT SPECT LI THIS SYSTEM ), g 6 9 6 m 0 2'11 ' h WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE 'J_ _ Bending PEX Tubing Side of Fireplace 36" 12" Et o H THIS SIGN". �= -� / I 1 t/4"Min. The minimum bend radius of Uponor PEX tubingIn anydirection is six times Front of Fireplace 60' 36" wean m m g O m }' 10.ALL INTERIOR PIPING TO BE UPONOR"AquaPEX®"UNLESS NOTED. - Bottom Max. the outside diameter(6 x OD). q2• 12• X `� Wood Burning Stove w o l E h z 1°"d S g m Fire Sprin der Adapter 9 Bend supports are available for 3/8",1/2",3/4"and 1"Uponor AquaPEX QC K z z o 0 0 MountingBracket Bracket to Face of Truss tubing to fadlitate 90-degree rigid bends. Kitchen Range 18" 9" J 5 c�g 6 C 1 rk °114 11.UPONOR"AquaPEX"TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. � Wall Oven 18" 9' U z2 $ 5 �_ ,�'v' 18" 9" fA,. `� q °zd°�, y 12.MINIMUM SPACING BETWEEN SPRINKLERS IS 8'-0' REFER TO SPACING CHARTS FOR MAXIMUM SPACING 2-#10 x 1 1/2"- /L/�{�CJ IJJ�- Recommended Tubing Length Between Fittings Hot Mr Fluesas a,,oa o-a< ,q `I BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE Full Course ` t� Fitting Size Minimum Tubing Length Uninsulated Heat Ducts 18" 9" 13:2 "0°z m by z , RESTRICTIVE SPACING LIMITATIONS. Thread Strews T Uninsulated Hot Water Pipes 12' 6' z °z y In Top Holes f a 3/8"ProPE)(Fitting 2" p v a o Side of Hot Air Diffuser 24" 12' o°�m 5 o m p 13.SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING °�4 a"2! S 5 g 112 1/2"ProPEX Fitting 2 1/2" Front of Hot Air Diffuser 36" 18" ° a rw MOUNTED OBSTRUCTIONS. \ 6" 3" z 0 4 o v°i m i?`� • 3/4"ProPEX Fitting 3 1/2" Hot Water Heater °z o m o ., o t o 14.THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE Lead-Free Flat r , - 6" 3" y o m y S t~C H SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. Conceale• en u Concealed Flat 1"ProPEX Fitting 4 1/2" Furnace o o z <0 d Sprinkler Head Cover Plate 1 1/4"ProPEX Fitting 5 1/2' 50W-250W Light Fixture 6' 3 E Fii o F3® o o®'g a 15.THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN 250W-499W Light Fixture 12' 6' u 1 3 M o S ua CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT IS >F y z °d EL THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. \ O t E M H H$ P o oT°d Exposed Installation Requirements. 16.NFPA 13D 8.2.5.OBSTRUCTIONS TO RESIDENTIAL SPRINKLERSUponor AquaPEX'""tubing(white)and ProPEXX'EP Fittings and ProPEX'" - - • 8.2.5.6°SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG ASBrass Fittings are approved for exposed installation where the following THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FTI PER SPRINKLER. conditions are met.(UL 1821 Approved) - • 8.2.5.7 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY 3 /� WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO Exposed Wood Joist Ceiling Assemblies. S ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. 1. Joists are of dimensional lumber,engineered wood,wood I-joist or open "' ^ m (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL -web wood joists. m SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; 2. Joist are of depths from 6-16 inches(152-204 mm). ❑ (a)THE FLOOR AREA SHALL NOT EXCEED 18 FT'(1.7 Ma) 3. Joist are of spacing from 12-24 Inches(305-610 mm)on center. Q (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 2 FT IN DEPTH AT THE DEEPEST POINT OF 4. Joists can be exposed after installation. \ \ THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED 5. Metal pipe hangers spaced at maximum 24 inches(610 mm)on center L 1.55 , / 1.66. 4, ALONG THE FINISHED FLOOR. are used. a (c)THEif FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE 6. Listed residential automatic sprinklers of maximum activation in-4" Hanger 1"Hanger a PLANE OF THE PRIMARY WALL. temperature rating of 15S°F(68°C). (d)MEASUREDSHALL OTE EXCEED THE MAXIMUUM LISTED SPACING OOINT OF THE ARCHITECTURAL SPRINKLER.KLER.O THE SPRINKLER Metal Tubing PP ort.Su Tubing Support Spacing: (Anchor AquaPEX Tubing Securely Enough to Support the Tubing,Yet Relaxed a (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE 1. Metal tubing supports designed for plastic tubing shall be used. Enough to Allow the Tubing to Expand and Contract) ARCHITECTURAL FEATURE. 2. Do not use supports that will damage the tubing.Inspect metal ''E supports for sharp edges. 1. Along Horizontal Runs,Install Supports Every 32",if Horizontal Runs are Cif 17.NFPA 13D 8.3 LOCATION OF SPRINKLERS. 3. Do not rigidly anchor Uponor AquaPEXm tubing with supports.Allow Continuously Supported,Place Tubing Supports at Six-Foot Intervals. • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 enough tubing for freedom of movement to expand and contract. 2. Along Vertical Runs,Install Supports Every Four to Five Feet,at Each of THROUGH 8.3.8. Floor and at a Mid-story Guide. 00 0 '0 • 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FTI(5.1 Ma)AND LESS 1 m 6 • 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT In-line Flow Test 3 m MEET ALL OF THE FOLLOWING CONDITIONS: m (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FTI(2.2 MI). The In-line Flow Test can be constructed on site. It performs a flow test to a A' °".is le (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE Standard Riser Assembly ensure proper system operation and flow(see Figure F001-8). u V:: o;. 8I MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. In a multi-purpose system a single control valve controls both domestic and W z z n k 6.3.4* SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND fire safety needs. (,) 9 Q n a mi a v Uponor AquaPEX ll i-m A' SIMILAR STRUCTURES jer 3 • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE Tubing i EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, m CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING LLJ O ii PURPOSES. i .e • 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR r� �i - ` =Q kn a u4 8.3.5.1.2. _ "!' 0,§151g0 ggg G. • 8.3.5.1.1 WHERE THE FUEL-FIRED EQUIPMENT IS ABOVE ALL OF THE OCCUPIED AREAS OF THE DWELLING -- J - I� r F O§y S=m 0 UNIT,NO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. / ProPEX Fire PJ O$a o•m O n • 8.3.5.1.2 WHERE FUEL-FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE Male Threaded Coupling LL ----- ‘1.71, DWELLING UNIT,AT LEAST ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE _��r SDrinkler Adapter q+ INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIRED I-I 1"Ball Valve EQUIPMENT FROM THE OCCUPIED SPACE. Male Threaded Couplin Ce '.� To Hot Water Heater 9 Y • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN COVERED,UNHEATED PROJECTIONS OF THE BUILDING AT 8 ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. 8. Female Threaded E • Pn ii P Tee with Water 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING E C z g Pressure Gauge O CONDITIONS: ggtt 1: (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED T° Sprinkler Orifice I rn I (Optional) Q N m$ i 100 FP(2.83 MI). 2 - "q o`N e? (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS E d Uponor Warning Signs Flow Test 0 N d SI rs ra AT THE LOWER CEILING ELEVATION. °if - -- m To ensure the systemprovides enough water for proper fire s rinkler Q S r0 r�A (3)•THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE ; N _ Y 9 p T g TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. 'n y (4)SKYLIGHTS NOT EXCEEDING 32 FTI(2.97 MI)SHALL BE PERMITTED TO HAVE A PLASTIC COVER. n performance,you should conduct a flow verification test. • .8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS c Note:The NFPA 13D Installation Standard does not require flow L///"� n .(REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR a n O H m o o verification. z VS ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED i Main Fire Sprinkler �.�/ PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. >u - Before performing a flow verification test,confirm the water pressures by 1..L qe z • 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING c c - Shut-off Valve contacting the Water and Sewer Department of your local city. Ensure the o u v g EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. 8 _ available water pressure matches the pressure used in the system design. O q R., 18. INSULATION GUIDE LINES PER NFPA 13D. cSHEET DESCRIPTION 9.1.1•WET PIPE SYSTEMS IN AREAS ABOVE 40°F. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE Note:The sprinklerklers plan indicates requirementseq the most hydraulically remote sprinklerconsult o '� (orourlocal sprinklers). For test on other sprinklers, GENERAL NOTES&DETAILS g USED WHERE ALL PIPING IS INSTALLED IN AREAS MAINTAINED ABOVE 40°F,INCLUDING AREAS PROPERLY INSULATED TO MAINTAIN 40°F. Note: It Is a good idea to notify the fire inspector at least 24 hours prior to •• A.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO performing a flow verification test.This may speed up the inspection !, E COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE process anti eliminate the need to repeat the test for the inspector. SHEET NUMBER GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.1.1(A)THROUGH FIGURE A.9.1.1(F) V' SHOW SEVERAL METHODS THAT CAN BE CONSIDERED.THESE ARE FOR ILLUSTRATIVE PURPOSES ONLY. Note:See"AquaSAFE Flow Test Instruction Sheet"(Provided in c CONSULTATION WITH THE GENERAL CONTRACTOR AND/OR OWNER IS RECOMMENDED TO ENSURE ' Contractors Documents package or online at www.Uponorpro.com)for 3 PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 40°F WILL BE MAINTAINED. _ more information on Flow Test Setup,Assembly,Performing the Test and 9 - Troubleshooting. If there are any questions please contact Uponor. FO 0 1 ,. © UPONOR - CONFIDENTIAL