Plans (5) Nt5r2o tri -ooc 3 5 r` -LiSK/ 1OP*kVA a • N Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE_LEGEND BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). z 8 Delete Line - --- XXX-XX - GREEN LINES=SPRINKLER HEAD TO SPEL RINKLER HEAD.PPLY. O „o 1 CITY OF TIGARD -- =1/2"PIPE SIZE > 8 f -MAXIMUM SPACING(TVP) ,.;',:go Add Line ---- --- - SPRINKLER MODEL(TYP) [X] _fi_ =3/4"PIPE SIZE HEAD SYMBOL(TVP) l Approved -i Conditionally Approved [ ] =1"PIPE SIZE Add Tee —iz— !N> =1-1/4"PIPE SIZE W LL r;12 T See Letter to:Follow [ ] Q. " g �°Z Add Elbow Es! 1 Attached , — oa ,1ls EC E!VE D =p•o Add Coupling S I 20 W. J Permit Number:/!'� a1" 7 W Address: l it t 443 SW 169 4vt= '"t W; Add Head ,�, ,�,- ti-�►G- S SEP 2 3 2019 . a a g By; a.GG. Date: Delete Head - - CITY OF TIGARD s!� 2° , •BUILDING DIVISION oo °ro& �s • Move Head -O- O- �� yC � a> � Note:All revisions must be reviewed by Uponor /� _ ^i r N a z b Table F002-1 - _- - • -_ o m g C, OM Multipurpose Fire Safety Systems I �1°c8 °`0E O The Uponor Residential Fire Safety System is a residential fire protections `,110,1320,1 00,_0 q�k a® r 1 system installed in combination with the cold side of the domestic potable Lu oE C m B_ \� water system. Only licensed contractors trained by Uponor can Install this °q�i p o o 3 0 [�] system. V 0.j y Fg'v( I?5°��i �y Fwd What to do if Changes are Required __-- _-_ M's+ Ea Om 4 � °}' r-L I�q��y f 6 a z l I FJ If any features or obstructions require the addition or deletion of sprinkler a y r heads,or significant relocation of sprinkler heads,contact the Uponor Design T Fp °o' y s Department to determine if observed changes require a redesign ` 'I 11 I ''S S O R 3 i 9 a o°y I' �. (888.594.7726). o5%agg„R6ss� Rg w adzS� d 0= oyN a O MOST HYDRAULICALLY REMOTE HEADS 1- ” oc:a z oJo w=E8 add iz HEAD# GPM PRESSURE REQ'D AT STREET ! � �� �� i ���l�a� lme� Ha W e ❑° .I 2. I ii 1 HEAD H.3 13 28.52 � _ HEM s� � $ ;��� , I - i r 2 HEAD H.9&H.6 26 43.3 �� 8a8o0�°1 u T — 'l FURS �f \l'',,—i �;'� L -- I: 1__i -r I- 1"AQUAPEX[NTERLEVEL / F-- 1"AQUAPEX INTERLEVEL - ! 1 LF SENJU Model RC-RES Residential Flat Concealed Pendent SS8464 CONNECTIONS FROM LOWER I r CONNECTIONS FROM LOWER - ' K=4.9,162E°,7/16"Orifice,Maximum Spacing 16'X16' FLOOR TO MIDDLE FLOOR FLOOR TO MIDDLE FLOOR 0 -H I RC-RES-16 Sprinkler head demand. 13 gpm @ 7.04 / iZ " li� _ J Cape -- x� q LF SENJU Model RC-RES175 Residential Flat Concealed Pendent SS8464 I1 �� _\ \ v 0 - - - 1 K=4.9,175E°,7/16"Orifice,Maximum Spacing 14'x14' �/ I � I o RC-RES-14-175 Sprinkler head demand: 13 gpm @ 7.04 \ \ - x --CAI I I \ 1.24 r j\ T.24 T.27 H.7 HI T 27 I \ -q8 ' /-• t. REQ. RC RES11fr �m. � Tlpj .28 l CO x 7 • e. � a� 7.S F ,U in0ie P a g I Ce z a w W O 1 FLOOR MOVE -.. -_. 1 a a ii c E o CURRENT STATIC EXTERIOR WALL ELEV=108' 8 8 8.,RT."o FO WATER PRESSURE / *' ° Lll ? STATIC: 55psi > - k \'1-1/4"AQUAPEX --- C 5 \ TO SYSTEM IC 5 z �'TO HOT WATER HEATER Q 0 ..�r E S.1 , Y I1"WATER METER / E�y_104• i; >°'�i a STANDARD LOSS PER NFPA 13D - // 0 m a ..�m us 1 (3PSI LOSS FLOWING 26GPM) -- - o t" I / 1-1/4"FULL PORT 1 LOWER FLOOR z LOWER FLOORMIRROR Q wZm�� a � / BALL VALVE I (,/') Q ? m C � a F100 "" "" C7 m o 0 N / F100 1/4"" = 1"-0"" 1/4 = 1'-0 - O . -o t g P 0 \ • ELEV-100' ELEV=1110' ////////////1 SHEET DESCRIPTION 1"METER LOWER FLOOR 35'OF 100'OF 8 1"COPPER-K 1-1/2"AQUAPEX SHEET NUMBER ° 3 WATER SERVICE DETAIL 15 F100 14 =r-0" e NTS FlOJ © UPONOR - CONFIDENTIAL r ' • Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND " BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). Y Delete Une - - ®XXX-XX ) BLACK LINES-SPRINKLER HEAD TO SPRINKLER HEAD. O GREEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. a -MAXIMUM SPACING ::: =1/2"PIPE SIZE C ^g o Add Une ---- -- -SPRINKLER MODEL(TYP) =3/4 PIPE SIZE 8-.',?:a a.U HEAD SYMBOL(TYP) =1"PIPE SIZE 0 u V,.n I m>� Add Tee 1- "4 ff =1-1/4"PIPE SIZE LL N z Add Elbow ` I ONnyg 0 fimo3 Add Coupling F---. 1 i m M` yi' "p`4m�m 1 W F41 1 OuPiF W Add Head -@.1\-- --�.3\- a Delete Head , �d>o R R o 9 z�259 7 zQ � ni - _ ¢ i Move Head - ORIoIgqo$E0@@ y po - -.- __ -- �ay�1OQS Q1o5Pa Note:All revisions must be reviewed b U nor ----- d;;2°°,4"°.6 m '. Table F002-1 --- �o¢go2�m�aO � _'� Multipurpose Fire Safety Systems r.1 °R,I S o pSafety System is a residential fire c�nr�`h C i B 9 i p i h O The Uponor Residential Fire Sa protections W 1 g m„,o�, system installed In combination with the cold side of the domestic potable r _ o d U z g q x g water system. Onlylicensed contractors trained by Uponor can Install this L _,- --, -� F 1 z -o 0 z system. -- r-- - yyQ Y I y ° ,z°� 6 What to do if Changes are Required �' t"I�� OVq If any features or obstructions require the addition or deletion of sprinkler I / C m o a o 4. S heads,or significant relocation of spookier heads,contact the Uponor Design \\H z o require a redesi n - \ W B g�z g; Department to determine if observed changes g I o^�m�5 q �� 1 (888.594.7726). ion 101 s� Za o o iso NRE a�}�ZM �qs�q g 1''.FlREPLACE ^`7 O m m `� r — q E o°2 Z I n H.2 d_ H.2 � a � z I FIREPLACE 'l I RC-RES-16 f) 01,M 8 a 8` i s � g �2C-RES-16 T.11 y 11 ,, T.11 - �, i i }--� H -� � 11111 � - I' F.3F.2 II 1"AQUAPEX INTERLEVEL 1"AQUAPEX INTERLEVEL I \ 1"AQUAPEX INTERLEVEL F.2 F.3 1" N. AQUAPEX INTERLEVELSFROM w �" I F FLOOR TO UPPE0.FLOOR CONN MIDDLE FLOOR \ \ H,� F.� a CONNECTIONS FROM MIDDLE \\ L�Pr'l � _ -1-77/ CONNECTIONS FROM MIDDLE FLOOR TOIIOID FROM LOWER�\ �' 1 - - FLOOR TO MIDDLE FLOOR \ - SC — i — - �RES 18 / / FLOOR TO UPPER FLOOR CONNECTIONS LOWER _ R N gc Res-rD T.18 \ � �! T16 T.18 � i / A\ _ o- .r \ 110` JE�' \ j \�`� ir T2 •, 0, 1 00 TF7 L �o F.7 \ \fib T.25 P . ..- E. , . T.22 • „T.26' N o E 8 a II H.81 I ULLJ 15 Gmy 0o I t 40IR E i� R 1Fr. t. it 0� T.3 ' ' i3 ', -• � _h' •.3 :33- T.33 W le ' A I'TTcr,11I F.8� ' o 01-W L p £ 6 el A, Is' 1 �1 .------- FO % ,' 1 U�U�i J m 2O0 W m _ > aL , I I �.,/� Y cc 2 E F- 5 E Q 0 ,N5a E a MIDDLE FLOOR 2 MIDDLE FLOOR — MIRROR Q �o' 2. n • A 1 = � �zmm-... le F101 1/41f = 11 _O" F101 1/4" = 11-0" O I1 m o 6 a 22 V, a'a DUO N Z SHEET DESCRIPTION Iii g MIDDLE FLOOR N O O 0. SHEET NUMBER n s is . _ _ — 3 MR 1 0 1 3 1/4"=1,0" 13 © UPONOR - CONFIDENTIAL F 1 0 1 ..a v Markup Legend SPRINKLER SYMBOL DEFINITION 1 COLOR/LINETYPE LEGEND � \`J/ BLUE FEED TO FIXTURES(BATH,SHOWER,ETC.). f o Delete Une OO XXX-XX GREEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. 6 Y BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. O a z MAXIMUM SPACING(TYP) tea— =1/2"PIPE SIZE >0 g g Add Une SPRINKLER MODEL(TYP) �c� =3/4"PIPE SIZE `~ °u HEAD SYMBOL(TYP) <m w I / =1"PIPE SIZE 0 u ��> Add Tee —,,,— =1-1/4“PIPE SIZE am; wo u ami uI Eli Add Elbow T C in Add Coupling l— 0 "q'-3 m Ou°,,itlair; Add Head 111-- 3- Delete Head - - F4-� AI 99 Fi 1p Move Head 0 0- .z �I Note:All revisions must be reviewed by Uponor b q ° v °!5< ° Q� E 8 Table F002-1 Q z Multipurpose Fire Safety Systems 4 The Uponor Residential Fire Safety System Is a residential fire protections , LOW d' B p ROOF W °° S system Installed in combination with the cold side of the domestic potable ROOF y) : d z m a„ water system. Only licensed contractors trained by Uponor can install this -- - _ ------ o s C a; system. What todolf Changes are Required o- W 0021W05:1 '1°' If any features or obstructions require the addition or deletion of sprinkler ' ' C m a F c3 H y b° heads,or significant relocation of sprinkler heads,contact the Uponor Design F d a o�r�' Department to determine if observed changes require a redesign z (888.594.7726). :.� o ° H.1' C H.1 �o6��0'45 a RC-RES-16 re"\ / 1 RGRES 16 g � 40811°-.81N§ T.10 s � � T.10 Eo� Oo � ." �.� I 1, � h� l' I �''' SD/CM - MJ\02 ,,',F..-.1_'-' .113 ,D;AR - H.3 '��/ T l3 F.1� +-� _ 1' 1'AQUAPEX INTERLEVEL R 1'AQUAPEX INTERLEVEL - RC-R�S"16 -- - / CONNECRONS FROM MIDDLE . CONNECTIONS FROM MIDDLE i -- - `�;1 FLOOR TO UPPER FLOOR T,44 -+� ,_"=" i FLOOR TO UPPER FLOOR 7 i / T<14 F�4 W y� H. 7�/ 7-.4-14 to w,p / a E RGRES-14 -0 0 4 - FL T1 �z; tai +--, H.6'c;• T_ T.19 -RES-16 I RGRES,16 ' , , T.19- i isl m __. I —Ej i `j i m T.23 T.23 3 0 _ /w ==a � r t - U 15mo'^.`a F g a•3RP 5� "r HJ H.9 w a Y '-e' I�—I , Ce s RGRES 18 Fi LLI o - o o2j QSWm . Z ii 2' 6 ' CeV( U 88aJ1=O pW N m N 3 ¢ O Io2�l E 7:1i 6 p' Y P 171 y 1 UPPER FLOOR 2 UPPER FLOOR - MIRROR Q ' zmN Floe 1�4t1 = l'-O" F102 1/4" = 1 t_011 (_/) o m 6 2 it it a H p� :.,i, 2 F-I E'3uill F.1 iOEgEdl Z SHEET DESCRIPTION 'a 0 UPPER FLOOR o 2 I SHEET NUMBER m 5 0 5 15 3 mg m ••1 iiimilimm 4F102;.. � © UPONOR - CONFIDENTIAL 3 • Senju RC-RES:Open Web Truss/TJI Construction Insulation Recommendations N A uaSAFETM' GENERAL NOTES: P See General Notes 8.2.5.7 for ArchitecturalIn areas subject to freezing,care should be taken in unheated attic spaces N 9 ProPEX LF Brass Fire to cover Uponor AquaPEX tubing completely with insulation. Insulation Feature Requirements u, Sprinkler Adapter Tee should follow the guidelines of the insulation manufacturer. See Uponor - - % z E 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2016 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM Fire Sprinkler Adapter Document"U or uaSAFE Attic Insulation Guldlines"for attic O Blocking Maybe , Pon Aq ` 0 0 SECTION 3.3.11.3. Required.If Push-on Nut Installation guidelines(Provided in Contractors Documents package or online �+ Blocking Is Used, 1�'"Min. at www.Uponorpro.com). i I z 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON -- - 4 > a Use The 2 Top THIS SHEET.THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND 1 t/Z Max. - Planter Box Window,Bay Window or Similar Feature. a >f UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. Screw Holes. } I Broom of Mounbng Extreme Temperature InstallationsD If no additinal floor area Is created No Additional Sprinkler Is Required. m O O Bracket to Fara of Truss AquaSAFE Residential Fire Safety systems are often installed in attics or a o,w 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE Fire Sprinkler Adapter ~- . ,I-. other areas exposed to temperature extremes of heat and/or cold. Follow 8'-0"or less I� 0 "' RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE MountingBracket the recommended extreme weather Installation instructions to Isolate and / of o m ak PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE �__� protect system components from extreme temperatures. Because this RC-RES-16 y v LL"Si z SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE } system also delivers domestic cold water directly to plumbing fixtures, 9'-0"or less It >N N z p SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. 3-510 x 1 1/2" •O x m rn - Uponor highly recommends that you protect the tubing with adequate / g� m .. Full Course - insulation in warm weather areas to minimize heating of the cold water ii t v w 3 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH Thread Screws 'b' U pp c t( ''''/ = is-.,n J NFPA 13D 2016 EDIRON. In Bottom Holes supply. i� yy gr t % et4a�mm{m JI"t 5. "STAND-ALONP OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE NOT PERMITTED TO USE ANTI-FREEZE. \ Installation methods include,but are not limited to: a�� O m w w 3 Tenting over the fire sprinkler piping. , 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR Lead-Free Flat _ - • Additional layers of batt insulation. If additional floor area is created.Cannot exceed 18 ft2,be more than 2'-0" j _ DAMAGED MUST BE REPLACED. Concealed Senju \ _ -- Concealed Flat • Increased depth of blown-In Insulation. deep,more than 9'-0"wide and be with In the coverage area of the < e g Sprinkler Head Cover Plate sprinkler.No Additional Sprinkler is Required. G x 7. WATER SHUT OFF VALVE IS NOT PERMITTED THAT ISOLATES THE SPRINKLER SYSTEM. Caution: If you will be Installing spray foam insulation,make sure to ,V,• z m g g2 Senju RC-RES:Traditional Wood FramingConstruction protect all components during application.Consult with the spray foam d o ® m 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. manufacturer to ensure compatibility with all products before application. NFPA 13D Table 7.5.5.3 Distances From 5 a i g o l o u a g U 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING,THE Heat Sources F m r b ` I WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND Consultation with local building officials is encouraged to ensure compliance _ a 9 with local buildingcodes. o q $v o 25 PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR ProPEX LO Brass Fire Ordinary Intermediate YY Fire Sprinkler Adapter b: o o a AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, Sprinkler Adapter TeeHeat Source Temp. Temp. of s N p FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM ' q Push-on Nut 135°-170° 1754-225° x o i m a d o WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE pp a S m o THIS SIGN". [ _ _(ice Bending PEX Tubing Side of Fireplace 36" 12" CI 5 M 9 z P �- 1 t/4 Min. The minimum bend radius of Uponor PEX tubing In any direction is six times Front of Fireplace 60" 36" 11 m m m.• 10.ALL INTERIOR PIPING TO BE UPONOR"AquaPEX®"UNLESS NOTED. 11/2'Max. the outside diameter(6 x OD), 42" 12" ti Fire Sprinkler Adapter Bottom d MounOn p� q Wood BurningStoveF z o o FlZ D Bend w rts are available for 3/8",1/2",3/4"and 1"Uponor AquaPEX - FQ+• o k z Liii Bracket to Face of Truss Kitchen Range 18" 9" J 5 5 o O `°O 11.UPONOR"AquaPEX"TUBING TO BE SUPPORTED PER NFPA 130 AND MANUFACTURER'S RECOMMENDATIONS. Mounting Bracket tubing to facilitate 90-degree rigid bends. 9 _ g FS o / Wall Oven 18' 9" id/044044g o. � E� fg 12.MINIMUM SPACING BETWEEN SPRINKLERS IS 8'-0" REFER TO SPACING CHARTS FOR MAXIMUM SPACING 2-610 x 1/2' / Q P Recommended Tubing Length Between Fittings Hot Air Flues 18" 9' H <�'�'d°d m BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE Full Coo -- ( 18' 9" C m P o,!mF g f-$C z a' i Fitting Size Minimum Tubing Length _Uninsulated Heat Ducts z d>o o, RESTRICTIVE SPACING LIMITATIONS. Thread S. sws2' 6" z 0 0 In TopHiles 'U 'Cl' Uninsulated Hot Water Pipes qqq lJ �J 3/8'ProPEX Fitting 2" 3 x i;m g 13.SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING Side of Hot Air r 24" 12" u S S p S y S 4 S MOUNTED OBSTRUCTIONS. 3 \ 1/2"ProPEX Fitting 2 1/2" Front of Hot Air Diffuser 36" 18" 73 Q Ca 6 3/4"ProPEX Fitting 3 1/2" Hot Water Heater 6' 3" g z m a o.0 3°uS of 5 a 14.THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE Lead-Fre.Flat o z u, o k t SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. - - 3'ProPEX Fitting 4 1/2" Furnace 6" 3" p",k m o y k' `+i C Conceal en u Concealed Flat c ca g z"'�°� Sprinkler Head Cover Rate 1 1/4"ProPEX Fitting5 1/2" 50W-250W Light Fixture 6" 3" 7 i g m o o 15.THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN 25OW-499W Light Fixture 12" 6" 'I u m n; M z z CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT IS > r�' o" c o S THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. \ O g n 0 8 MOM a of • Exposed Installation Requirements. \ __ N 16.NFPA 13D 8.2.5`OBSTRUCTIONS TO RESIDENTIAL SPRINKLERS T" • 8.2.5.6• SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS Uponor AquaPEX tubing(white)and Prostalla EP Fittings and Plowing� - THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FT.PER SPRINKLER. Brass Fittings are approved for exposed installation where the following 8.2.5.7 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY conditions are met.(UL 1821 Approved) WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: o '"mt. lZ /� 7® (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO Exposed Wood Joist Ceiling Assemblies. o - H ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. 1. Joists are of dimensional lumber,engineered wood,wood I-joist or open '•' 7.55 m(2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL web wood joists. mSPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; 2. Joist are of depths from 6-16 inches(152-204 mm). ❑(a)THE FLOOR AREA SHALL NOT EXCEED 18 FT2(1.7 M2) 3. Joist are of spadng from 12-24 Inches(305-610 mm)on center. Q(b)THE FLOOR AREA SHALL NOT BE GREATER THAN 2 FT IN DEPTH AT THE DEEPEST POINT OF 4. Joists can be exposed after installation. \ \THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED 5. Metal pipe hangers spaced at maximum 24 inches(610 mm)on center X 1.66' ALONG THE FINISHED FLOOR. are used. I (c)THE FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE 6. Listed residential automatic sprinklers of maximum activation Zn-4"Hanger 1"Hanger v PLANE OF THE PRIMARY WALL. temperature rating of 155°F(68°C). o (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER Tubing Support Spacing: SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. Metal Tubing Support. F4 (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE 1. Metal tubing supports designed for plastic tubing shall be used. En(Aough AquaPEX Tubing g Securely Enough to nt act) the Tubing,Yet Relaxed ARCHITECTURAL FEATURE. Enough to Allow the Tubing to Expand and Contract) 2. Do not use supports that will damage the tubing.Inspect metal .. supports for sharp edges. 1. Along Horizontal Runs,Install Supports Every 32",if Horizontal Runs are c 17.NFPA 130 8.3 LOCATION OF SPRINKLERS. 3. Do not rigidly anchor Uponor AquaPEXT1°tubing with supports.Allow Continuously Supported,Place Tubing Supports at Six-Foot Intervals. • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 enough tubing for freedom of movement to expand and contract. 2. Along Vertical Runs,Install Supports Every Four to Five Feet,at Each THROUGH 8.3.8. Floor and at a Mid-story Guide. 0 c • 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FT.(5.1 M2)AND LESS E • 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT In-line Flow Test t z.w c. BMEET ALL OF THE FOLLOWING CONDITIONS: 3 w m (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FT.(2.2 M2). The In-line Flow Test can be constructed on site. It performs a flow test to a o m m o x (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE Standard Riser Assembly ensure proper system operation and flow(see Figure F001-8). 0 S n.. $ MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. In a muni-purpose system a single control valve controls both domestic and LLI z z v r E • 8.3.4*SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND fire safety needs. V a o m" F SIMILAR STRUCTURES Uponor AquaPEX I tp N 1-co„ • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE Tubing /7 2 EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND g Y CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, / 11 PURPOSES.CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING - - z o .. z0 # • 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR j iiLLJ IMIIIIIIM �I j� ` =Q cn a 8 8.3.5.1.2. • , ///'''' c • 8.3.5.1.1 WHERE THE FUEL-FIRED EQUIPMENT IS ABOVE ALL OF THE OCCUPIED AREAS OF THE DWELLING - E z�z w yi UNIT,NO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. Lim 1 x rn 8.3.5.1.2 WHERE FUEL-FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE $a z O m • Q Male Threaded Coupling ProPIX Fire V,J O DWELLING UNIT,AT LEAST ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE �r.I. Sprinkler Adapter LI ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIRED EQUIPMENT FROM THE OCCUPIED SPACE. M 1"Ball Valve �1 V • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN COVERED,UNHEATED PROJECTIONS OF THE BUILDING AT E. To Hot Water Heater Male Threaded Coupling - �r ../ 8 ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. Female Threaded LL E • 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING _ E .�. Tee with Water _ F-- i! CONDITIONS: n Pressure Gauge O a g (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED _ �, Sprinkler Orifice - (Optional) Q c x g > 100 FTa(2.83 Ma). % m U U , 6 y 51 (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS a d = Y 0 c i tL z m AT THE LOWER CEILING ELEVATION. E Y Uponor Warning Signs Flow Test ti ao n x▪: (3)°THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE Yn s - To ensure the system provides enough water for proper fire sprinkler T z m .. TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. G'i m performance,you should conduct a flow verification test. y g (4)SKYLIGHTS NOT EXCEEDING 32 FT.(2.97 M2)SHALL BE PERMITTED TO HAVE A PLASTIC COVER. y EI i ") Q m y j�z k�i • 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS Nota:The NFPA 13D Installation Standard does not require flow V A � i E m p o. o 4 (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR ti verification. O p I z w F ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTEDSprinklerperforming �/ 3 e 22. co a Main Fire LL o PENETRATIONS'.DIRECTLY INTO THE DWELLING UNIT. I aBefore a flow verification test,confirm the water pressures by .O1-• • 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING s = -- Shut-off Valve contacting the Water and Sewer Department of your local city. Ensure the g p, g EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. 8 c available water pressure matches the pressure used in the system design. - fi a s SHEET DESCRIPTION n18. INSULATION GUIDE LINES PER NFPA 13D. c 3 Note:The sprinkler plan indicates the most hydraulically remote sprinkler o • 9.1.1"WET PIPE SYSTEMS IN AREAS ABOVE 40°F.A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE o (or pair of sprinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DETAILS USED WHERE ALL PIPING IS INSTALLED IN AREAS MAINTAINED ABOVE 40OF,INCLUDING AREAS PROPERLY a your local code. p g INSULATED TO MAINTAIN 40oF. Note: t[is a good to notify the fire inspector at least 24 hours prior to A.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO Note: ing a flowIdeanThis may up the 24inhours aL' COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE process and eliminate the verificationnetest.to repeat the speedest for the inspector.ection SHEET NUMBER 1in GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.1.1(A)THROUGH FIGURE A.9.1.1(F) SHOW SEVERAL METHODS THAT CAN BE CONSIDERED.THESE ARE FOR ILLUSTRATIVE PURPOSES ONLY. Note:See"AquaSAFE Flow Test Instruction Sheet"(Provided in ii CONSULTATION WITH THE GENERAL CONTRACTOR AND/OR OWNER IS RECOMMENDED TO ENSURE 1 Contractors Documents package or online at www.Uponorpro.com)for PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 40°F WILL BE MAINTAINED. -7 more Information on Flow Test Setup,Assembly,Performing the Test and 3 Troubleshooting. If there are any questions please contact Uponor. © UPONOR - CONFIDENTIAL F001