Loading...
PFI2019-00282 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT COMMUNITY DEVELOPMENT Permit#: PF12019-00282 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 10/03/2019 TIGARDParcel: SEG784 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: PGE Project Description: SEG 784. Replace wood pole. PGE Job#M2775403 Class of Work: FEES Description Date Amount Type 1 Utilities (gas, electric, data) PFI Permit Fee 10/02/2019 $300.00 Total $300.00 Owner: REQUIRED INSPECTIONS Call 503-639-4175 for the IVR inspection request line or visit the City of PHONE: Tigard website at www.tigard-or.qov to schedule inspections online. Contractor: PHONE: Applicant: RODRIGO SOLIS 10800 SW AVERY STREET TUALATIN, OR 97062 PHONE: 5034647777 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant Signature: See application Issued By: 111111111 Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PFI2019-00282 Type: Condition Name: Status: Severity: PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law, the Tigard Municipal Code,and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition,free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be reinstalled or replaced, with like kind of material. Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition,American Traffic Safety Services Association [ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area. Traffic control devices,flag persons, etc., shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503-629-0111 (Tigard Police Dept.,Tualatin Fire& Rescue) and to 503-962-8140 (Tri-Met) and 503-431-2345 (Tigard School District) and other service providers impacted by such closure. PFI_Utilities 08-TRAFFIC CONTROL ADVANCE WARNING Applied Notice Advance warning of traffic disruption shall be provided to the public by placement of an approved advance notification sign at each end of the construction area 72 hours (min.) before initiation of construction work. PFI_Utilities 09-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI_Utilities 10-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 11 -TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 12-TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 13-DRAINAGE CONTROL Applied Notice Drainage shall be controlled within the work site and shall not adversely affect adjacent private property, public property and the receiving system. The City may at any time order corrective action and suspension of work to accomplish effective drainage control. PFI_Utilities 14-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 15-UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 16-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 17- REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities (roads, ditches, etc.)as may be necessary, as determined by the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 19- PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity,the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert Phone#>,to establish a preconstruction meeting. PFI_Utilities 20-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24) hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. PFI_Utilities 21 - PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 22- DAILY INSPECTION REPORTS Applied Notice Applicant shall submit daily inspection reports, on a weekly basis, to the City's Inspector. PFI_Utilities 23-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 24-VALIDATION OF MATERIAL/CONSTRUCTION Applied Notice The City's Inspector may, at his discretion, require tests and or reports from the applicant to validate claims of material or construction adequacy/compliance. Such tests/reports shall be provided at the applicant's expense. PFI_Utilities 25- EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing, the names and 24 hour emergency telephone number of two (2) persons who have authority to resolve problems, take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing, of any/all assignment changes. PFI_Utilities 26- RIGHT OF ENTRY/EASEMENTS Applied Notice Applicant to obtain proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry or properly executed easements, shall be provided to the City. The City shall in no way be construed to be liable for the applicant's failure to obtain or provide for proof of right-of-entry or easements. PFI_Utilities 27-PRIVATE PROPERTY AGREEMENTS Applied Notice Provide the City a copy of an executed agreement[s]from the owner for each private property disturbed by construction activity. PFI_Utilities 28-AS-BUILT DRAWING Applied Notice 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance (Certificate of Compliance). 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance (Certificate of Compliance). One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance (Certificate of Compliance). PFI_Utilities 31 -OTHER Applied Notice Other RECEIVED SEP 0 3 2019 City of Tigard CITY OF TIGARD PFI#: 20 l�j—oo22 C . ENGINEERING DEPARTPI jF 'MING/ENGINEERING TIGARD Public Facilities Improvement (PFI) Permit PROJECT INFORMATION PGE Job # M2775403 TYPE OF WORK Project name: 8 TYPE 1—Franchise Utility Work performed by NWN,PGE, or utility Brief description of project: agency Replace Wood Pole. ❑ TYPE 2—ROW Sidewalk/Driveway/Sewer Work performed for the purpose of: • Sidewalk installation or repair • Driveway approach installation and repair SITE INFORMATION • Sanitary sewer lateral installation and main line tap Location (address if available): ❑ TYPE 3—Full Scale Development Work 11700 SW Gallo Ave Tigard, OR 97223 S '4,01- performed with land use approval which includes any of the following: • Subdivisions or Partitions APPLICANT INFORMATION • Street widening Name: Joseph Fraedrich for Portland General Electric • Mainline installation for sanitary sewer, storm sewer, Tigard water, and Tigard Mailing address: 10800 SW Avery Street water service area City/State: Tualatin, ORZip. 97062 ❑ TYPE 4—Small Cell Technology 503-464-7777 ❑ TYPE 5—Tigard Triangle Phone: Email: preregcoord@pgn.com Phone: NOTE: Type 1 and 2 applications may be Contact name: Rodrigo Torres Solis emailed to rowpermits@tigard-or.gov. Phone: 503-403-9084 Email: CONTRACTOR INFORMATION 0 Same as applicant Name: Portland General Electric CCB Number: Mailing address: 10800 SW Avery City/State: Tualatin, OR Zip: 97062 Phone: Email: preregcoord@pgn.com ENGINEER INFORMATION Name: Mailing address: City/State: Zip: Phone: Email: ADDITIONAL INFORMATION Estimated value of work is required(if over$5,000):$ (within the public right-of-way) Is work related to a LAND USE DECISION? EYes ElNo Case number: City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 1 of 4 APPLICANTS NOTE: Person specified as"Applicant" shall be designated"Permittee"and shall provide financial assurance for work,if required by the city pursuant to TMC 15.04.140. * With the exception of a utility operating pursuant to a valid franchise or license with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner must sign this application in the space provided or submit a written authorization with this application. Franchised or Licensed Utilities are not required to obtain the owner's signature on the application. I, the applicant, certify that: • To the best of my knowledge,all the information provided within this application package is complete and accurate. • The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject property. • If the application is granted,I will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. Joseph Fraedrich DDiay0si80e3b0y1oe51 F-0ra0h Joseph Fraedrich for Rodrigo Torres Solis 8/30/19 Applicant's or authorized agent's signature Print name Date Property owner's signature (if required) Print name Date STAFF USE ONLY Case NoPP(2l 002- Permit fee: -544'-uv Received by: 4,— Date:`? 3 I? Approved by: `✓Y•vti 1f Date: v/JI/9 Notified by: SC Date: 41'3- City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 2 of 4 DEVELOPMENT ENGINEERING FEES Public Facility Improvement(PFI)Permit: INITIAL PFI PERMIT FEE Part 1: Required submittal fee is 10%of the Net PFI Permit Fee.See below for calculations.Minimum of$300. NET PFI PERMIT FEE Part 2: All non-water system improvements engineer's estimate X 7%(less the initial PFI Permit Fee). WATER LINE CONSTRUCTION FEE Part 3: All public water system improvements engineer's estimate X 12%. FOR S'I AI F l Si:ONL) FOR STAFF I'SE ONLY TYPE 4: SMALL WIRELESS FACILITY TYPE 1—3: DETAILED SUBMITTAL CIIECKLIS'T REQUIREMENTS Does applicant have a right-of-way license? 0 Yes ❑No TYPE 1 AND TYPE 2-Must include a sketch showing: Under the wireless facilities standards,is the proposal ❑ Dimensions considered?(check all that apply): 0 Small Cell 0 Macro ❑ Street Name How many install sites are proposed as part of this permit ❑ Site Address application? TYPE 3-Must provide 4 sets of plans (sized 24 x 36 or 22 x 34) and an electronic version of all submittal The proposed equipment is located on which of the following: items. The plans must that include: 0 Public Right-of-Way ❑Private Property ❑ Cover—Site,Vicinity,Abbreviation,Legend If equipment is to be located on private property,describe the 111 General Notes(City,Water,Sewer,etc.) type&use: ❑ Street(Plan,Profile) ❑ Water,Storm and Sanitary(Plan Profile) ❑ Water Quality Facilities ❑ Grading ❑ Landscaping/Tree Plan ❑ Composite Utility Plan(Electrical,Phone,Gas, Storm, Sanitary,Water,Signage,Street Lights,etc.) ❑ Details ❑ Traffic Sight Distance ❑ Signing and Striping ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label(project land use name,revision and plan log block,dates and sheet numbers.) ❑ Engineer's Construction Estimate Additional Submittals (per land use conditions,if applicable) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design ❑ Water Provider Approval City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 3 of 4 9 sly- yy " si Edge of Pavement 'un—.Ditch Streetlight —r— i At ilk I or 12amDnm ;��`;... fes. • .w ' I I 1 T—propos' d'S erriine" I ›' rnE Existing House I r„r 1 Existing F. '. • Driveway d� v! I 1 Cl -' 1/1 rI YI pi 41/.4.! r ' 3I a°I vim' 41 c/a oi 1 L ' Existing Shop 1 I J 1 Powerpole I w I ' I 0 2:'. 1`r I' 95' Io ------157474Lme---------' I0 I FHydrant(FH) I I • Scale: 'I"=30' I I I I I I I I TYPE 1 AND TYPE 2: lIINII;M SKETCH REQUIREMENTS (Put N/A if not applicable) North arrow Property lines&dimensions Existing utilities locations (sewer, storm,water) Street& street names All existing structures Proposed work Existing curb or edge of pavement Utility&street light poles Existing S/W or D/W apron Slope of property Trees City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 4 of 4 �e7'N THINK LIGHTING LEGEND �cu0X ouok �Frr (UNLESS OTHERWISE SPECIFIED) FIRS11 MN REMOVE PGE FACILITIES B 75 8203 REPLACE LAMINATED WOOD POLE WITH PD-17520 20'-2 BLACK FIBERGLASS POLE WITH A 39W —910 C�Dx FUSE AT OURCE,CONNECT @ 240VLOBE LESS TOWN&COUNTRY LED LIGHT, INSTALL 3OAMP FUSES IN SECONDARY PEDESTALS OR SECONDARY VAULTS (WHICHEVER IS ST LT POINT OF ATTACHMENT) FOR EACH STREET LIGHT PER PGE T$D CONSTRUCTION STANDARD LC-11550 02CONSTRUCTION NOTES: SLCST 11700 1,CUSTOMER TO PROVIDE ALL TRENCHING,BACKFILLING CONDUIT,ELBOWS,JUNCTION 48 INCHESDEEPAND30DINCHEISWIDE,MEASUREDFROM FINALGRAH DE.i';I:8---- W ALL PGE CONDUCTORS TO BE INSTALLED IN GRAY,SCHEDULE 40,ELECTRICAL GRADE,PVC CONDUIT 15178 NYLON PULL STRINGS(MIN.500 LBS.TEST). PGE TO DETERMINE THE SIZE AND NUMBER OF CONDUITS REQUIRED. 11715 Q CE BETWEEN GAS AND OTHER UMAINTAIN 12 TILITIES.. ALL ELBOWS 4 NAL INCHES AND 24 CHTB SMALLER TO BE 36AL INCHES N INCH RADIUS. o Cl 1-340 RIGID STEEL OR PGE APPROVED FIBERGLASS BENDS ARE REQUIRED FOR RUNS OF 151 FEET OR LONGER.OR FOR ANY LENGTH RUN WITH MORE THAN 180 DEGREES IN BENDS.PVC SCHEDULE 40 BENDS ARE ACCEPTABLE FOR RUNS OF 150 FEET OR Q Q LESS.THE MAXIMUM TOTAL BENDS IN ANY CONDUIT RUN IS 270 DEGREES.ALL BENDS ST BE FACTORY MADE.REFER TO LETTER OF RESPONSIBILITY FOR a 3 y 2.A PGE STANDBY CREW IS REQUIRED FOR OPENING ALL ENERGIZED PGE VAULTS. INSTALLATIONS, 80259 JVNCTI D BOXES AND ESTRING.CALL SERVICE INCLUDING CONNECTION OR 20'� ..._ _.__..__... TO SCHEDULE A PGE STANDBY CREW. A_.1985 OF CONDUITS AN PULL STRINGS.CALL COORDINATION AT 503-323-6700 - 4 80259 3.ALL CONCRETE FOOTINGS NEED TO BE INSTALLED WITH TOP OF BASE 20,2 FLUSH TO CURB I SIDEWALK. CONTACT SERVICE COORDINATOR 4.CUSTOMER RESPONSIBLE FOR ROAD CROSSINGS.ALL CROSSINGS MUST EXTEND FROM PROPERTY LINE TO PROPERTY LINE.CROSSINGS TO BE 48 INCHES DEEP. MEASURED FROM FINAL GRADE. .017.01 ANOCONINAT RiSPECTIOH MOP �/yyl�'7 C.00R(MNR248 S.DIRECTIONAL BORING WITH A MECHANICALN:BLACK HDPE(HIGH DENSITY POLYETHYLENE DUCT 503333870008 W0."' 818 OR CONNECTION 40 PVC 7W�ITAS ANALTERNATIVE LERNCONNECTION(CERTA-LOK OR LIKE TITHE MECHANICAL REQUIREMENTS OF SPECIFICATION LC20515(A ELABLR ON RTHOTNRT EQUALLY SPACEJCT CALL 811 BEFORE YOU DIC MANAGER FOR SAFETY REASONS THE DUCT S ATTENTION: EXTRUDED RED STRIPES(WHICH IS A SPECIFICATION REQUIREMENT? MANDREL TEST OF OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED1 HDPE PIPE IS REQUIRED AFTER INSTALLATION WITH PGE INSPECTOR PRESENT. 1 BY THE OREGON UTILITY NOTIFICATION CENTER. THOSE RULES ARE SET FORTH IN OAR 952.001.0010 6.TRANSFORMER PADS ARE TO BE SET SO THAT THE TOP IS 2 INCHES ABOVE THROUGH Bu4p10090.YOU MAY OBTAN COPES OF FINAL GRADE. CONDUIT IS TO BE INSTALLED IN PAD AS INDICATED IN DETAIL 'THE— 1 ...FILL POE WALL NOT IMIALL WIRE RULES BY CALLING THE OREGON UTILITY ''T, % AND TO EXTEND 1 INCH ABOVE THE PAD. "35 NOTIFICATION CENTER AOLfiSTMT10N®(603232-1987] 7.ALL PGE TRANSFORMERS TO BE INSTALLED 8 FEET(MIM FROM ANY COMBUSTIBLE NCATES CALL THE OREGON w.v.H sbelow. BUILDING,WALL OR OVERHANG AND 4 FEET(MIM FROM ANY FIRE HYDRANT. i.:1 CENTER.811 AT LEAST PGE TRANSFORMERS MUST BE WITHIN 15 FEET OF A DRIVEABLE AREA. IIP PRIOR TO EXCAVATION. Call before MI1810• ALWAYS MAINTAIN 10 FEET CLEARANCE IN FRONT OF ALL TRANSFORMERS. ;w TIo.m sl VICINITY MAP _. 2 PIECE FIBERGLASS (COMPOSITE)POLE 8.STEEL BARRIER POSTS ARE REQUIRED AROUND TRANSFORMERS THAT ARE EXPOSED TO VEHICLES. 9.AS NEEDED-FRONT LOT PUBLIC UTILITY EASEMENT(P.U.E) TO BE 8 FEET(MIM Boll Bong I' �L:I- Top Se<lie^51ipf 10 FEET(PREFERRED). 4 Toped Oyer Slob Side of Condon I ' I T 10.CONSULT WITH PGE REPRESENTATIVE 2 WEEKS BEFORE STARTING MAIN POWER TRENCHING FOR A PRECONSTRUCTION CONFERENCE. INCLUDED IN THIS CONFERENCE Pok WILL BE EXCAVATOR,POE,TELCO,CATV.AND GAS. Stub a'�O"e 11.CUSTOMER TRENCH AND ELBOW CONFIGURATIONS,ALL CONDUITVAULT AND PAD SectionFlnrsM1 Grade INSTALLATIONS MUST BE INSPECTED BY PGE PRIOR TO BACKFILLING.WHEN YOU ARE READY FOR PGE TO INSPECT(AFTER INSTALLATION IS COMPLETE CALL 503-736-5450" See Note 2 OR 5034634348(SALEM 13( ALLOW UP TO 2 WORKING DAY FOR INSPECTION TO OCCUR 12.REFER TO THE POE ELECTRIC SERVICE REQUIREMENTS BOOKLET FOR SPECIFIC REQUIREMENTS. For Installing 'N.. 5001 Lew'Empty 13,DESIGN IS BASED ON STANDARD UNDERGROUND EQUIPMENT.NON-STANDARD UNDER- 5cmws �,I,• I 1'Wow Fnish Grade GROUND EOUIPMENT MAY BE AN OPTION AT AN ADDITIONAL COST TO THE CUSTOMER. TLLewe Extra Rock Ior(orWRWI PGE CONSTRUCTION DRAWING r s = DATE:8/28/19 scALE:NTg !ACCOUNT:1070001 lAWo: 1000009106 lJOB No.512775403 TITLE s 11111 City of Tigard/PL 80259 11700 SarthwaSr see Nen I . 34-Rodeos Elbows j CIRCUIT SIZE G lin Avenue w'-Avws S0F002'"g°",OIOIAi°" Y!/ TIGARD-13361 11x17 S' Crushed Rock JOB SITE• - PGE LOCATION BOTTOM PIECE POLE INSTALLATION N. 11700 SW Gallo Ave,TIGARD DESCRIPTION 0 I. romped 3/1-inch mire,.crushed rock backfin Replace EOL Laminated wood pole w/20'FG DB 2-PC black,39W LED MC 10,uked around all poles and loonngx COUNTY SECTION(S) WORK WITH SHEET 0.Cane WG.- ropa,dl.se er,eil sopdman eo mainnin WASHINGTON C11-340 V Wicker 1100' prop..pole ang,mr.m. BEAVERTON 1 OF 1 2. (PGE Pte 1025221 M•.nr,tarn. LINE CREW CENTER DESIGN BV PHONE(503) DRAWN BY (PGE PM OIRI)18OoyeTlU eRh Tek too 2213 SW 153RD DR RICO SOLIS 672-5417 CESAR DEL ROSARIO oM en.b b pewnlmblon olpd'rap. BEAVERTON.OR 9700e 0 PORTLAND GENERAL ELECTRIC CO.-ALL RIGHTS RESERVED