Report (2) P PS 2.on- co/24 /0 575 cAscProe.tae. RECFP 4L./0 SEP 25 2019 CITY OFTIGARD * • 66 VII VAT 1431.11LONG DIVISION FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard, OR 97223 BIAMP SYSTEMS CASCADE AVE 10575 SW CASADE TIGARD OR 97223 FIRE PROTECTION EQUIPMENT SUBMITTAL Worldwide www.tyco-fire.com ti,ca . Contacts Series TY-FRB — 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General of copper alloy sprinklers beyond that which would otherwise be obtained Description when exposed to corrosive atmo- spheres. Although corrosion resistant The Series TY FRB, 5.6 K factor, Hori coated sprinklers have passed the — zontal and Vertical Sidewall Sprinklers standard corrosion tests of the appli- cable in this data sheet are quick cable approval agencies,the testing is �„ � *�' not representative of all possible cor k response standard coverage, rosive atmospheres. Consequently, % i , orative 3 mm glass bulb type spray it is recommended that the end user sprinklers designed for use in light and ordinary hazard, commercial occu be consulted with respect to the suit- ordinary such as banks, hotels, shop ability of these coatings for any given ping malls, etc. They are designed for corrosive environment. The effects of installation along a wall or the side of ambient temperature,concentration of a beam and just beneath a smooth chemicals, and gas/chemical velocity, ceiling. Sidewall sprinklers are com should be considered, as a minimum, monly used instead of pendent or along with the corrosive nature of the upright sprinklers due to aesthetics or chemical to which the sprinklers will be building construction considerations, exposed. where piping across the ceiling is not ,,e1, " ,?i '-, desirable. NOTICE The recessed version of the Series The Series TY-FRB Sprinklers � .+- ' lir TY-FRB Horizontal Sidewall Sprinkler described herein must be installed f , t<< is intended for use in areas with a fin and maintained in compliance with )x , ished wall. It uses a two-piece Style this document, as well as with the applicable standards of the National 10 Recessed Escutcheon with 1/2 in. , (12,7 mm)of recessed adjustment or up Fire Protection Association,in addition to 3/4 in.(19,1 mm)of total adjustment to the standards of any other authori- from the flush sidewall position, or a ties having jurisdiction.Failure to do so y j mayimpair theperformance of these two-piece Style 20 Recessed Escutch- p ,, eon with 1/4 in. (6,4 mm) of recessed devices. adjustment or up to 1/2 in. (12,7 mm) The owner is responsible for main '' „ ' of total adjustment from the flush side- taining their fire protection system wall position.The adjustment provided and devices in proper operating con- by the Recessed Escutcheon reduces dition. Contact the installing contrac- Technical the accuracy to which the fixed pipe tor or product manufacturer with any nipples to the sprinklers must be cut. questions. Data Corrosion resistant coatings, where applicable,are utilized to extend the life Sprinkler Approvals UL and C-UL Listed Identification FM Approved IMPORTANT LPCB Approved Refer to Technical Data Sheet Numbers NYC Approved TFP2300 for warnings pertaining to (Refer to Table A for complete approval _ regulatory and health information. TY3331 Horizontal information including corrosion resistant Always refer to Technical Data TY3431 Vertical status.) Sheet TFP700 for the "INSTALLER Maximum Working Pressure WARNING" that provides cautions Refer to Table B with respect to handling and instal Discharge Coefficient lation of sprinkler systems and com- ponents. Improper handling and K=5.6 GPM/psi1i2(80,6 LPM/bar1i2) installation can permanently damage Temperature Ratings a sprinkler system or its compo- Refer to Table A nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 JULY 2018 TFP176 TFP176 Page 2 of 6 DEFLECTOR \ DEFLECTOR 1 - Frame HAT 5 1 - Frame HAT 5 2 - Button �1��j✓w�r 2 - Button 3 - Sealing _R\ 3 - Sealing — Assembly 4 Assembly S,. r/,i 4 - Bulb t 4 - Bulb 5 - Compression / �'�� 5 - Compression a � Screw Screw 6 - Deflector* 6*/ 4 2 3 1 6 - Deflector* 6*/ 4 2 3 1 ' 9/16" WRENCH 1/2"** 9/16" WRENCH 1/2" (14,3 mm) FLATS NPT (14,3 mm) FLATS NPT Iik r. r`7 ill ��� i* -�� 41111110, *Allirill 1 1 .,:lir 411Mw. V 1-13/16" 7/16" 1-13/16" 7/16" (46,0 mm) / (11,1 mm) (46,0 mm) / (11,1 mm) CENTERLINE NOMINAL CENTERLINE NOMINAL OF SPRINKLER MAKE IN OF SPRINKLER MAKE-IN WATERWAY WATERWAY 1 1/2" 1-1/2" x(38,1 mm)y x(38,1 mm) ESCUTCHEON ESCUTCHEON PLATE SEATING 2-3/16" PLATE SEATING 2-3/16" SURFACE (55,6 mm) SURFACE (55,6 mm) STYLE 10 or 20 i 1 STYLE 10 RECESSED RECESSED ESCUTCHEON ri ESCUTCHEON I ■ *Temperature rating is /�11 *Temperature rating is /�1� indicated on Deflector II:4C,�IIIIIIIIIIII indicated on Deflector 110E119, ** Pipe thread connectionsecl per ISO 7-1 can be provided on special 2-7/8" DIA. 2-7/8" DIA. request (73,0 mm) (73,0 mm) ALL FINISHES EXCEPT POLY-STAINLESS POLY-STAINLESS FINISH ONLY FIGURE 1 5.6 K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL(TY3331)SPRINKLERS Finishes Poly-Stainless Design Sprinkler:Refer to Table C Physical Characteristics i - Recessed Escutcheon:Signal or Pure Frame Bronze Criteria White,Jet Black,Grey Aluminum,Chrome Bulb Button L316 Stainless Glass Plated,Plated,or Brass Plated Compression Screw L316 Stainless Steel* The Series TY-FRB, 5.6 K-factor, Hor- HSW Ph sical Characteristics Deflector Copper/Bronze izontal and Vertical Sidewall Sprin- g Sealing Assembly.Gold Plated Beryllium Nickel k Frame Bronze w/TEFLON lers are intended for fire protection Button Brass/Copper *Type L316 stainless steel(UNS 31603)per ASTM systems designed in accordance with Sealing Assembly..Beryllium Nickel w/TEFLON A479/479M or BS EN 1008 WN1.4404. the standard installation rules rec- Bulb Glass ognized by the applicable Listing or Compression Screw Bronze Operation Approval agency (e.g., UL Listing is HSW Deflector Bronze VSW Deflector Copper based on the requirements of NFPA The glass bulb contains a fluid which 13, and FM Approval is based on the expands when exposed to heat.When requirements of FM's Loss Prevention the rated temperature is reached, the Data Sheets). Only the Style 10 or 20 fluid expands sufficiently to shatter the Recessed Escutcheon, as applicable, glass bulb, allowing the sprinkler to is to be used for recessed horizontal activate and water to flow. installations. TFP176 Page 3 of 6 Installation *Temperature ** Pipe thread 1 - Frame 4 - Bulb 7 - Ejection rating is connections 2 - Button 5 - Compression Spring The Series TY-FRB, 5.6 K-factor, Hori- indicated on per ISO 7-1 can 3 - Sealing Screw zontal and Vertical Sidewall Sprinklers Deflector. be provided on Assembly 6 - Deflector* must be installed in accordance with special request. this section. , ARROW MUST ` General Instructions POINT AWAY /K Do not install any bulb type sprinkler 7/16" FROM AND BE if the bulb is cracked or there is a loss ESCUTCHEON (11,1 mm) PERPENDICULAR f O of liquid from the bulb.With the sprin- PLATE SEATING NOMINAL TO THE BACK kler held horizontally,a small air bubble SURFACE NPT** MAKE-IN WALL SURFACE4 should be present.The diameter of the air bubble is approximately 1/16 in. j 6* (1,6 mm) for the 135°F (57°C) to I -r�`���— =�*`\� _ 3/32 in. (2,4 mm)for the 286°F(141°C) �r� temperature ratings. '1 FLOW'' 5 A leak tight 1/2 in. NPT sprinkler joint 2-3/16" AM Ah 2 3/16" I 4 should be obtained with a torque of (55,6 mm) f - (55,6 mm) 7 to 14 lb-ft (9,5 to 19,0 N•m). Higher 1-1/2" \ R * 2 levels of torque may distort the sprin- (38,1 mm) 1 WRENCH/ _ I t kler and cause leakage or impairment FLATS 7 # 3 of the sprinkler. . Do not attempt to make-up for insuf- 1 ficient adjustment in the escutcheon SHOWN SHOWN CROSS plate by under-or over-tightening the PENDENT UPRIGHT SECTION sprinkler. Readjust the position of the sprinkler fitting to suit. FIGURE 2 5.6 K-FACTOR QUICK RESPONSE Series TY-FRB Horizontal and SERIES TY-FRB VERTICAL SIDEWALL(TY3431)SPRINKLERS Vertical Sidewall Sprinkler Installation Series TY-FRB Recessed The Series TY-FRB Horizontal and Horizontal Sidewall Sprinkler Care and Vertical Sidewall Sprinklers must be Installation installed in accordance with the fol- The Series TY FRB Recessed Horizon Maintenance lowing instructions. tal Sidewall Sprinklers must be installed The Series TY FRB, 5.6 K-factor, Hori Step 1. Horizontal sidewall sprinklers in accordance with this section. _zontal and Vertical Sidewall Sprinklers are to be installed in the horizontal Step A. Recessed horizontal sidewall must be maintained and serviced in position with their centerline of water- sprinklers are to be installed in the hori- accordance with this section. way perpendicular to the back wall and zontal position with their centerline of parallel to the ceiling.The word "TOP" waterway perpendicular to the back Before closing a fire protection system on the Deflector is to face towards the wall and parallel to the ceiling. The main control valve for maintenance ceiling. work on the fire protection system that word "TOP"on the Deflector is to face it controls,permission to shut down the Vertical sidewall sprinklers are to be towards the ceiling. affected fire protection system must be installed in the pendent or upright Step B.After installing the Style 10 or obtained from the proper authorities position with the arrow on the Deflec 20 Mounting Plate over the sprinkler and all personnel who may be affected tor pointing away from the wall. threads, hand tighten the sprinkler into by this action must be notified. Step 2. With pipe thread sealant the sprinkler fitting. Absence of an escutcheon, which is applied to the pipe threads, hand Step C. Tighten the sprinkler into the used to cover a clearance hole, may tighten the sprinkler into the sprinkler sprinkler fitting using only the W-Type delay the time to sprinkler operation in fitting. 7 Recessed Sprinkler Wrench (Ref. a fire situation. Step 3. Tighten the sprinkler into the Figure 6). With reference to Figure Sprinklers that are found to be leaking sprinkler fitting using only the W-Type 1, the W-Type 7 Recessed Sprinkler or exhibiting visible signs of corrosion 6 Sprinkler Wrench(Ref.Figure 5),With Wrench is to be applied to the sprin- must be replaced. reference to Figure 1 or 2, the W-Type kler wrench flats. 6 Sprinkler Wrench is to be applied to Step D. After the ceiling has been Automatic sprinklers must never be the wrench flats. installed or the finish coat has been painted, plated, coated or other- `Mise altered after leaving the factory. applied, slide on the Style 10 or 20 Modified sprinklers must be replaced. Closure over the Series TY-FRB Sprin- Sprinklers that have been exposed to kler and push the Closure over the corrosive products of combustion, but Mounting Plate until its flange comes in contact with the ceiling. have not operated,should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Spriklers TFP176 Page 4 of 6 5/8±1/4" G� y (15,9±6,4 mm) MOUNTING FACE OF / WRENCH RECESS SURFACE SPRINKLER (END"A"USED FOR FITTING 1/2" NPT MODELS) / ./....4 FIGURE 5 CLOSURE A W-TYPE 6 SPRINKLER WRENCH (73,0 DIA. nn (73,0 mm) SERIES I■:�,AIIII 2- 4(517/,2" 57 2D A). WRENCH RECESS MOUNTING `• PLATE Ii kisaer/o � 1/8" - (3,2 mm) PUSH WRENCH 1-1/4" (31,8 mm) 3/4"(19,1 mm) IN TO ENSURE 3/4"(19,1 mm) 1/4"(6,4 mm) ENGAGEMENT WITH SPRINKLER FIGURE 3 WRENCHING AREA SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER FIGURE 6 WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON W-TYPE 7 RECESSED SPRINKLER WRENCH 1/2±1/8" (12,7±3,2 mm) MOUNTING FACE OF SURFACE SPRINKLER FITTING CLOSURE 11�1 A t 2-7/8" DIA. SERIES Imo' (73,0 mm) TY FRB ��� nlll 2 1/4" DIA. (57,2 mm) `l MOUNTING 1 PLATE /1 1/8" (3,2 mm) 1-1/4" (31,8 mm) 1/2"(12,7 mm) 1"(25,4 mm) 1/4"(6,4 mm) FIGURE 4 SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFP176 Page 5 of 6 SPRINKLER FINISH(See Note 11) K TYPE TEMP. BULB NATURAL CHROME pOLYESTERb POLY- LEAD LIQUID BRASS PLATED STAINLESSc COATED 135°F(57°C) Orange HORIZ. 155°F(68°C) Red SIDEWALL 175°F(79°C) Yellow 1,2,3,4,9, 10 1,2,3,9 1,2 1,2,3,9 (TY3331) 200°F(93°C) Green 286°F(141°C) Blue 5.6 RECESSED 135°F(57°C) Orange 1/2 in. HORIZ. 155°F(68°C) Red NPT SIDEWALL 1,2,4,9, 10 1,2,9 1,2 N/A (TY3331)a 175°F(79°C) Yellow Figure 3 200°F(93°C) Green RECESSED 135°F(57°C) Orange HORIZ. 155°F(68°C) Red SIDEWALL 1,2,3,4,9 N/A N/A (TY3331)b 175°F(79°C) Yellow Figure 4 200°F(93°C) Green VERTICAL 135°F(57°C) Orange SIDEWALL 155°F(68°C) Red 5.6 (TY3431) 1/2 in. Installed 175°F(79°C) Yellow 5,6,7,8,9 N/A 5,6,7,9 NPT Pendent or 200°F(93°C) Green Upright 286°F(141°C) Blue NOTES: 1. Listed by Underwriters Laboratories,Inc.(UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 in.(100 to 300 mm)top of deflec- tor to ceiling distance. 2. Listed by Underwriters Laboratories Inc.for use in Canada(C-UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 in.(100 to 300 mm)top of deflector to ceiling distance. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers for use in Light Hazard Occupancies at a 4 to 12 in.(100 to 300 mm)top of deflector to ceiling distance. 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007a/04)at a 4 to 6 in.(100 to 150 mm)top of deflector to ceiling distance.The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. 5. Listed by Underwriters Laboratories,Inc.as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. 6. Listed by Underwriters Laboratories for use in Canada(C-UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. 7. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers for use in Light Hazard Occupancies. 8. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06&007a/04)as Quick Response Sprinklers. 9. Approved by the City of New York under MEA 354-01-E. 10.Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)at a 4 to 6 in.(100 to 150 mm)top of deflector to ceiling distance.The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. 11.Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as Corrosion Resistant Sprinklers. a. Installed with Style 10(1/2 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon. b. Installed with Style 20(1/2 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon. c. Frame and deflector only. TABLE A LABORATORY LISTINGS AND APPROVALS damaged by dropping,striking,wrench Thereafter, annual inspections per ing contractor or product manufacturer twist/slippage, or the like, must be NFPA 25 should suffice; however, with any questions. replaced. Also, replace any sprikler instead of inspecting from the floor It is recommended that automatic that has a cracked bulb or that has lost level, a random sampling of close-up sprinkler systems be inspected,tested, liquid from its bulb. (Ref. Installation visual inspections should be made, so and maintained by a qualified Inspec- Section).Section). as to better determine the exact sprin tion Service in accordance with local The owner must assure that the sprin kler condition and the long term integ- The and/or national codes. klers are not used for hanging any rity of the corrosion resistant coating, objects and that the sprinklers are only as it may be affected by the corrosive cleaned by means of gently dusting conditions present. with a feather duster; otherwise, non- The owner is responsible for the operation in the event of a fire or inad- inspection,testing,and maintenance of vertent operation may result. their fire protection system and devices Frequent visual inspections are rec in compliance with this document, as ommended to be initially performed well as with the applicable standards for corrosion resistant coated sprin- klers, after the installation has been ciation (e.g., NFPA 25), in addition to completed, to verify the integrity the standards of any other authorities of the corrosion resistant coating. having jurisdiction. Contact the install TFP176 Page 6 of 6 SPRINKLER FINISH K TYPE NATURAL BRASS CHROME PLATED POLYESTER LEAD COATED HORIZONTAL SIDEWALL(TY3331) 250 PSI or,2 BAR) 175PSI(12,1 BAR) 5.6 RECESSED HORIZ. 1/2 in. SIDEWALL(TY3331) (SEE NOTE 1) NPT VERTICAL SIDEWALL (TY3431) 175 PSI(12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories,Inc.(UL);the Listing by Underwriters Laboratories,Inc.for use in • Canada(C-UL);and,the Approval by the City of New York. TABLE B MAXIMUM WORKING PRESSURE P/N 57 - XXX - X - XXX SIN SPRINKLER TEMPERATURE FINISH RATINGS 378 HORIZONTAL SIDEWALL TY3331 1 NATURAL BRASS 135 135°F(57°C) POLY-STAINLESS GREY 155 155°F(68°C) 375 VERTICAL SIDEWALL TY3431 2 ALUMINUM(RAL9007)1 POLYESTER 175 175°F(79°C) 3 PURE WHITE(RAL9010)2 POLYESTER 200 200°F(93°C) 4 SIGNAL WHITE(RAL9003) POLYESTER 286 286°F(141°C) 5 JET BLACK(RAL9005)3 POLYESTER 7 LEAD COATED 9 CHROME PLATED NOTES: 1. Available for TY3331 only. 2. Eastern Hemisphere sales only. 3. Available in 155°F(68°C)or 200°F(93°C temperature rating only. TABLE C PART NUMBER SELECTION SERIES TY-FRB HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS Limited Ordering Recessed Escutcheon 7 Specify: Style (10 or 20) Recessed Warranty Procedure tch on with (specify") finish, P/N (specify") For warranty terms and conditions,visit Contact your local distributor for avail- *Refer to Technical Data Sheet TFP770 www.tyco-fire.com ability.When placing an order, indicate Sprinkler Wrench the full product name and Part Number Specify: W-Type 6 Sprinkler Wrench, (P/N). P/N 56-000-6-387 Sprinkler Assemblies with NPT Specify: W-Type 7 Sprinkler Wrench, Thread Connections: P/N 56-850-4-001 Specify: Series TY-FRB(specify SIN), (specify K-factor),(specify) Horizontal Sidewall or Vertical Sidewall Sprinkler, Standard Response,Standard Coverage,(specify)temperature rating, (specify)finish or coating, P/N (specify from Table C) 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone,+1-215-362-0700 02018 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson �� `I NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registeretl tratlamarks of National Fire Protection Association; Controls TEFLON is a registeretl trademark of DuPont ti,co Worldwde Contacts Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The TYCO Series TY-FRB Sprinklers ,, t') Description described herein must be installed and maintained in compliance with = , The TYCO Series TY-FRB,5.6 K-factor, this document, as well as with the Upright (TY313) and Pendent (TY323) applicable standards of the National t Sprinklers described in this data sheet Fire Protection Association,in additionP„ �_ are quick response,standard coverage, to the standards of any other authori- " decorative 3 mm glass bulb-type spray ties having jurisdiction.Failure to do so " 111.1111 sprinklers designed for use in light or may impair the performance of these ordinary hazard,commercial occupan- devices. cies such as banks, hotels, and shop- . . The owner is responsible for main- � ping malls. taining their fire protection system The recessed version of the Series and devices in proper operating con- TY-FRB Pendent Sprinkler, where dition. Contact the installing contrac- applicable, is intended for use in areas tor or product manufacturer with any with a finished ceiling. This recessed questions. pendent sprinkler uses one of the ,,,,, .. following: Sprinkler it • A two-piece Style 15 Recessed Escutcheon with recessed adjust- Identification t'' � merit up to 5/8 in. (15,9 mm) from `" the flush pendent position. Number (SIN) • A two-piece Style 20 Recessed TY313. . . . Upright 5.6K, 1/2 in. NPT v . « •d Escutcheon with recessed adjust TY323. . . .Pendent 5.6K, 1/2 in. NPT " ment up to 1/2 in. (12,7 mm) from the flush pendent position. Technical The adjustment provided by the Data Operation Recessed Escutcheon reduces the accuracy to which the fixed pipe drops The glass bulb contains a fluid which to the sprinklers must be cut. Approvals expands when exposed to heat.When Intermediate level versions of Series Refer to Table A the rated temperature is reached, the TY-FRB Sprinklers are described in Maximum Working Pressure fluid expands sufficiently to shatter the Technical Data Sheet TFP357. Sprin- 175 psi(12.1 bar) glass bulb, allowing the sprinkler to sl(17.2 bar)* activate and water to flow. 250 kler guards and shields are described psi in Technical Data Sheet TFP78O. *The maximum working pressure of 250 psi(17.2 bar) Design only applies to the listing by Underwriters Laborato- ries,Inc.(UL). Discharge Coefficient Criteria IMPORTANT K=5.6 GPM/psi'/=(80,6 LPM/bar'%) The TYCO Series TY-FRB,5.6 K-factor, Refer to Technical Data Sheet Temperature Rating Upright (TY313) and Pendent (TY323) TFP2300 for warnings pertaining to Refer to Table A Sprinklers are intended for fire protec- regulatory and health information. tion systems designed in accordance Always refer to Technical Data Finishes Sprinkler: the standard installation rules Sheet TFP700 for the "INSTALLER Sprinkler:Refer to Table B recognized by the applicable Listing or WARNING" that provides cautions Recessed Escutcheon:White Coated, Approval agency (such as, UL Listing with respect to handling and instal- Black Coated,Chrome Plated,or Brass is based on the requirements of NFPA lation of sprinkler systems and com- Plated 13, and FM Approval is based on the ponents. Improper handling and Physical Characteristics requirements of FM's Loss Prevention installation can permanently damage Frame Bronze Data Sheets).Only the Style 15 or Style a sprinkler system or its compo- Button Brass/Copper 20 Recessed Escutcheon is to be used nents and cause the sprinkler to fail Sealing Assembly...Stainless Steel w/TEFLON for recessed pendent installations. to operate in a fire situation or cause Bulb Glass it to operate prematurely. Compression Screw Bronze Deflector Bronze Page 1 of 4 AUGUST 2018 TFP172 TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 Frame 4 Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* --- / 5 ll r 7/16" orr-ruvrr (11,1 mm) �-- } ���Ri c _ 4 I NOMINAL lii 2"M )cI 411 AKE-IN _ (50,8 mm) 1 2 D! �� (50 2.',8 mm) \I\l] II/ 1-3/8" (34,9 mm) W 3 WRENCH FLATS 1/2"NPT** DEFLECTOR* - 2-7/8" (73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Installation Step 2. With pipe-thread sealant Lv applied to the pipe threads, hand- TheTYCO Series TY FRB,5.6 K factor, tighten the sprinkler into the sprinkler WRENCH RECESS Upright (TY313) and Pendent (TY323) fitting. (USE ONLY Sprinklers must be installed in accor- Step 3. Tighten the sprinkler into the END"A") dance with this section. sprinkler fitting using only the W Type ^ 6 Sprinkler Wrench(Figure 2).With ref- General Instructions erence to Figure 1,apply the W Type 6 FIGURE2 Do not install any bulb type sprin Sprinkler Wrench to the wrench flats. W-TYPE 6 kler if the bulb is cracked or there is Torque sprinklers 7 to 14 Ib-ft (9,5 to SPRINKLER WRENCHa loss ofliquid from the bulb.With the 19,0 N•m). sprinkler held horizontally, a small air bubble should be present. The diam- Pendent Sprinklers WRENCH eter of the air bubble is approximately The Series TY-FRB Recessed Pendent RECESS 1/16 in.(1,6 mm)for the 135°F(57°C)and Sprinklers must be installed in accor- 3/32 in. (2,4 mm)for the 286°F(141°C) dance with the following instructions. ���1 temperature ratings. Step A. After installing the Style 15 41 r(� A leak-tight 1/2 in. NPT sprinkler joint or Style 20 Mounting Plate over the should be obtained by applying a sprinkler threads,and with pipe thread minimum to maximum torque of 7 to sealant applied to the pipe threads, ., 14 Ib ft(9,5 to 19,0 N•m). Higher levels hand tighten the sprinkler into the \r� of torque can distort the sprinkler Inlet sprinkler fitting• with consequent leakage or impairment Step B. Tighten the sprinkler into the PUSH WRENCH of the sprinkler. IN TO ENSURE sprinkler fitting using only the W-Type ENGAGEMENT Do not attempt to compensate for 7 Recessed Sprinkler Wrench (Figure WITH SPRINKLER insufficient adjustment in the Escutch- 3).With reference to Figure 1,apply the WRENCHING AREA eon Plate by under- or over-tightening W-Type 7 Recessed Sprinkler Wrench the sprinkler. Re adjust the position of to the sprinkler wrench flats. Torque FIGURE 3 the sprinkler fitting to suit. sprinklers 7 to 14 lb-ft(9,5 to 19,0 N•m). W-TYPE 7 RECESSED SPRINKLER WRENCH Upright and Pendent Sprinklers Step C. After ceiling installation and The Series TY-FRB Upright and finishing, slide on the Style 15 or Style Pendent Sprinklers must be installed 20 Closure over the Series TY-FRB in accordance with the following Sprinkler and push the Closure over the instructions. Mounting Plate until its flange comes in Step 1.Install Pendent sprinklers in the contact with the ceiling. pendent position. Install upright sprin- klers in the upright position. TFP172 Page 3 of 4 Care and 2-7/8" DIA. - (73,0 mm) Maintenance 2-1/4" DIA. The TYCO Series TY-FRB,5.6 K-factor, FACE OF (57,2 mm) Upright (TY313) and Pendent (TY323) SPRINKLER Sprinklers must be maintained and ser- FITTING 5/8"(15,9 mm) viced in accordance with this section. + 1 — , ; FLUSH Before closing a fire protection system 3/8±5/16" main control valve for maintenance (9,5±7,9 mm) / All �m Iv work on the fire protection system } / that it controls, obtain permission to �_. shut down the affected fire protection MOUNTING 1/8" systems from the proper authorities SURFACE (3,2 mm) and notify all personnel who may be CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) affected by this action. TY-FRB PLATE 3/4"(19,1 mm) Absence of the outer piece of an escutcheon, which is used to cover FIGURE4 a clearance hole, can delay sprinkler SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) operation in a fire situation. WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only - 2-7/8" DIA. _ cleaned by means of gently dusting (73,0 mm) with a feather duster; otherwise, non- FACE OF operation in the event of a fire or inad- SPRINKLER 2-1/4" DIA. vertent operation may result. FITTING (57,2 mm) Sprinklers which are found to be 5/16±1/4" 12,7 leaking or exhibiting visible signs of (7,9±6,4 mm) 1/2" ( mm) corrosion must be replaced. FLUSH Automatic sprinklers must never be ='1 I r ,7 painted, plated, coated, or other- 7 AI wise altered after leaving the factory. I / _go, Modified sprinklers must be replaced. MOUNTING 1/8" Sprinklers that have been exposed to SURFACE =� (3,2 mm) - corrosive products of combustion, but t have not operated,should be replaced I if they cannot be completely cleaned CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) by wiping the sprinkler with a cloth or TY-FRB PLATE 7/8" (22,2 mm) by brushing it with a soft bristle brush. FIGURE 5 Care must be exercised to avoid SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) damage to the sprinklers before, WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 during, and after installation. Sprin- RECESSED ESCUTCHEON klers damaged by dropping, striking, wrench twist/slippage,or the like,must Limited Recessed Escutcheon be replaced. Also, replace any sprin- Specify: Style 15 Recessed Escutch- kler that has a cracked bulb or that has warrant�/ eon with(specify`)finish, P/N(specify") lost liquid from its bulb. (Ref. Installs 1 Specify: Style 20 Recessed Escutch- tion Section.) For warranty terms and conditions,visit eon with(specify*)finish, P/N(specify") The owner is responsible for the www.tyco-fire.com. "Refer to Technical Data Sheet TFP770 inspection,testing,and maintenance of their fire protection system and devices Ordering Sprinkler Wrench in compliance with this document, as Specify: W-Type 6 Sprinkler Wrench, well as with the applicable standards Procedure P/N 56-000-6-387 of the National Fire Protection Asso- Specify: W-Type 7 Sprinkler Wrench, ciation (e.g., NFPA 25), in addition to Contact your local distributor for avail- P/N 56-850-4-001 the standards of any other authorities ability.When placing an order,indicate having jurisdiction.Contact the install- the full product name and Part Number ing contractor or product manufacturer (P/N). with any questions. Sprinkler Assemblies with NPT Automatic sprinkler systems are rec- Thread Connections ommended to be inspected, tested, Specify: Series TY-FRB Upright or and maintained by a qualified Inspec- Pendent (specify) Sprinkler, SIN tion Service in accordance with local (specify), K-5.6, Quick Response, requirements and/or national codes. (specify) p g, (specify) s ecif temperature rating, finish, P/N (specify,refer to Table A). TFP172 Page 4 of 4 SPRINKLER FINISH(See Note 7) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME POLYESTERC FACTOR COLOR BRASS PLATED 135°F(57°C) Orange UPRIGHT 155°F(68°C) Red (TY313) and 175°F(79°C) Yellow 1,2,3,4,5,6 PENDENT (TY323) 200°F(93°C) Green 5.6 1/2 in.NPT 286°F(141°C) Blue 135°F(57°C) Orange RECESSED 155°F(68°C) Red PENDENT 1,2,3,4 (TY323) 175°F(79°C) Yellow Figures 45 and 5b 200°F(93°C) Green Notes: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. VdS Approved(For details,contact Johnson Controls,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-54-428-3377.) 6. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. a. Installed with Style 15(1/2 in.NPT)5/8 in.Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only.Listings and approvals apply to color(Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS P/Na 77 — XXX — X — XXX SIN SPRINKLER TEMPERATURE FINISH RATINGS 370 5.6K UPRIGHT(1/2 in.NPT) TY313 1 NATURAL BRASS 135 135°F(57°C) 371 5.6K PENDENT(1/2 in.NPT) TY323 3 PURE WHITE(RAL9010)a 155 155°F(68°C) POLYESTER Notes: SIGNAL WHITE(RAL9003) a. Use suffix"I"for ISO 7-1 connection;for example, 4 175 175°F(79°C ( )POLYESTER 77-370-4-175-I 5 JET BLACK(RAL9005) 200 200°F(93°C) POLYESTER 9 CHROME PLATED 286 286°F(141°C) Notes: a. Eastern Hemisphere sales only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 WO ®2018 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association, Controls TEFLON is a registered trademark of DuPont Eddythread 40 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS ,:'s ' •w i on.7.4 1t 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS NOMINAL PIPE SIZE (in) SCHEDULE 40 EDDYTHREAD 40 1 1.00 1.00 1 1/4 1.00 1.00 1 1/2 1.00 1.00 2 1.00 1.00 *Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems el• 1819 Clason Road For a inform ion, Chest rfield, MO 63017 contadctt yoursalespersontoday at ClOus A j l BUM003E TUBE COMPANY (800)325-4467 (800)325-4467 or(636)537-2600 LISTED CJ LL FAX:(636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 44(11::) A CR fl o company e-mail:sales(2 bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 Ductile Iron Threaded Fittings „.„,,,,„„,,,„„,,, „„:„:,_,,,,,,,::::,„:„..,„,,,, ,,„:„.„,,,,, �" ...„ kS>+,r SMlA {iF�+&.,„..„,...,.....,, - ,,..:,,,,,,,:,: ,s-,„.„,,,,,,..,,,,,„„..„. ,,,,,,,,,,,,,,,,,:,,--- � 4 al. �`" a ;€ , Yju173 Ali t,r a „,,,,,„,„.„,„,,,,,,,,.....„.:,,,,,,,„, ,,,,,,,,„„,4„,„,„,„„,... ,„.....,„„,„„, • .... •••:,;,: 1,,7,17,,,f,, z,„ ,.iii• eF:, ➢t}S j f Vit,„ ii i oty , 4•j,1441,4,—;44,44,,,t' » E t o +, , s (,.L 2" i P. .. ,ass + ; `NEE'v.. .'"" ;.* ani t1 r g a I . '§ y "� {f t y t +' 11 ��• "'-• iER s 6 E '° ip kk a Y'„ • „,� ',. SSP b 3 5it' „.' • i71770 y fY4 d ii+£a`t.;; c+Ya x 4�. , ,..,„•': • 7 it 4 u' RA t ft i�Po , � A G` Ci Y ' s y..•. e: •V!f gY a N psr : . • 6a "' nt!Nn b C s I f } �� is ,.,:.‘,•::;11::10 lto ,xILV —1',..' ii,• ffi i! t qP ” 1f 94;11,4��� i p` 11 4 w rP E ,A ''''''„Y'4-...,'''!'''::' ` ; i'� i n k bks p. vel.€ i�41 °5 41, ,y Pq , . *r .. [ ihl,;m.4414 ,�@p06 ,,,," sr k _,`� y ,if v �P 51:8 NjP s. °r E ";�pp� piq 'r. Fn; • : y5. 14114.,;:' a ,'!' tt�w t�ti °• Eki"��t{ 3 k �CSw4. k�P�Iiisi hi f w SMITHi, COOPER INTERNATIONAL Ductile Iron Threaded Fittings Specifications • CI branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP C CO Ductile iron castings conform to ASTM A536 US • LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical &physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working Pressure, Nonshock psiG Degrees F 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 r4-11 I Ductile Iron Fittings- Class 300 UL/FM Q L! c ® uS APPROVED LISTED A Fig. 35E 3-90°Elbow • Size A Packing Weight r,. ...�� Part Number - ,„ in in Inner Master lb 1/2 35E 3004 1.13 100 200 0.2 �►i 3/4 35E 3006 1.31 70 140 0.3 %iA 35E 3010 1.50 40 80 0.5 ,da ._ 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3-90°Reducing Elbow B SizeA B Packing Weight _ > in Part Number in in Inner Master lb 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 �i A 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45°Elbow Size Part Number A Packing Weight A in in Inner Master lb /# 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 41 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 1-1/2 35F 3014 1.44 20 40 1.0 !�' IA 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size Part Number A Packing Weight �i-,� in in Inner Master lb lEl A 1/2 35T 3004 1.13 80 160 0.3 - 111 I 3/4 3513006 1.31 30 60 0.5 IIII 1 351 3010 1.50 25 50 0.7 t»�.�.,..siv 1-1/4 35T 3012 1.75 10 20 1.1 A A 1-1/2 351 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com „s. Ductile Iron Fittings- Class 300 UL/FM c ® us APPROVED Fig. 35RT3-Reducing Tee LISTED al �, _ Size Part Number A B C Packing Weight IaI► in in in in Inner Master Ib i C 3/4 x 1/2 35R13006004 1.20 1.20 1.22 60 120 0.4 I1 x 1/2 35E313010004 1.26 1.26 1.36 30 60 0.6 !� -i 1 x 1/2 x 1 35013010004010 1.50 1.36 1.50 30 60 0 6 I � I 1 x 3!4 35RT3010006 1.38 1.38 1.45 25 50 0.6 e .ice) 1 x 3/4 x 3/4 35013010006006 1.38 1.31 1.45 35 70 0.6 B A 1 x 3/4 x 1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 - 1-1/4 x 3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35R13012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 35R13012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35R13012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 x 1 x 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4 x 1 x 1-1/4 35R13012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35013014004 1.41 1.41 1.66 16 32 1.0 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35R13014004014 1.94` 1.66 1.94 12 24 1.2 1-1/2 x 3/4 35013014006 1.52 1.52 1.75 16 32 1.1 1-1/2 x 3/4 x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-1/2 35013014006014 1.94 1.75 1.94 18 36 1.2 1-1/2 x 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2 x 1 x 1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2 x 1 x 3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2 x 1"x 1-1/4 35R13014010012 1.82 1.67 1.88 12 24 1.2 1-1/2 x 1 x 1-1/2 35013014010014 1.94 1.80 1.94 12 24 1.3 1-1/2 x 1-1/4 35R13014012 1.82 1.82 1.88 12 24 1.4 1-1/2 x 1-1/4 x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2 x 1-1/4 x 3/4 35013014012006 1.52 1.45 1.75 16 32 1.0 1-1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2x 1-1/4 x 1-1/4 35013014012012 1.82 1.75 1.88 14 28 1.3 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2 x 1/2 35R13020004 1.49 1.49 1.88 10 20 1.5 2x3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2 x 1 35813020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 35013020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 216 8 16 2.1 2 x 1-1/2 x 1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2 x 1-1/2 x 3/4 35R13020014006 1.60 1.52 1.97 10 20 1.4 2 x 1-1/2 x 1 35813020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35R13020014012 1.90 1.82 210 8 16 1.7 2 x 1-1/2 x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35RT3-Bull Head Tee , Size Part Number A B C Packing Weight ';E�;f in in in in Inner Master lb „„j &,.„ IC 3/4 x 1 35B13006010 1.45 1.45 1.37 30 60 0.6 dIMIEI 1 x 1-1/4 35813010012 1.67 1.67 1.58 20 40 0.9 - . 1 x 1-1/2 35B13010014 1.80 1.80 1.65 15 30 1.0 A I B 1-1/4 x 1 x 1-1/2 35B13012010014 1.88 1.80 1.82 15 30 1.2 1-1/4 x 1-1/2 35B13012014 1.88 1.88 1.82 15 30 1.3 1-1/4 x 2 35B13012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 35B13014012020 2.16 2.10 2.02 10 20 1.8 1-1/2 x 2 35B13014020 2.16 216 2.02 8 16 1.8 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 112 '. Ductile Iron Fittings - Class 300 UL/FM :OwiriftuW, c ® us APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED 111111 • Size Part Number A Packing Weight I in in Inner Master lb -. III 111 1 112 35CP3004 38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling Size Part Number A Packing Weight IS p; in in 1.69 Ib � A 1 x 1/2 35RC3010004 80 160 0.3 1 x 3/4 35RC3010006 1.69 60 120 0.4 %;� 1-1/4 x 3/4 35RC3012006 2.06 40 Inner Master 80 0.6 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size Part Number A Packing Weight B in in Inner Master lb 1 x 1/2 35HB3010004 1.06 180 360 0.2 j ^A 1 x 3/4 35HB3010006 1.06 180 360 0.1 Ir 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 1 1-1/2 x 1 35HB3014010 1.25 75 150 0.4 . • 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 80 0.6 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 Fig. 35SP3 -Square Head Plug Size Part Number A Packing Weight in in Inner Master lb 1/2 35S83004 0,94 600 1200 0.07 I4i 3/4 35SP3006 1.17 350 700 0.1 IA 1 35S83010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35U 3- Union with Brass Seat A Size A Packing Weight Part Number in in Inner Master lb 1,, 4 1 35U 3010 2.19 20 40 1.0 �' 1-1/4 35U 3012 2.50 15 30 1.2 1 1-1/2 350 3014 2.62 10 20 1.7 61111h •�_ 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL° • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 1 Ductile Iron Fittings- Class 300 UL/FM 1QU: YPS c (Do us APPROVED Fig. 35X 3-Cross LISTED A •i(--4 Size A Packing Weight �I in Part Number in Inner Master lb WO �T#� ���� A1 35X 3010 1.50 20 40 0.9 1-1/4 35X 3012 1.75 12 24 1.4 • d .r 1I =I 1-1/2 35X3014 1.94 8 16 1.8 `_� I IA 2 35X 3020 2.25 6 12 2.8 gust/ 13 B Fig. 35RX3-Reducing Cross �'` Size Part Number A B Packing Weight ■■'�.� in in in Inner Master lb N` 1 g- IA 1 1-1/4 x 1 353X3012010 1.67 1.58 15 30 1.2 m--i-- 1-1/2 x 1 353X3014010 1.80 1.65 12 24 1.4 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 A Fig. 35C 3- Cap Size Part Number A Packing Weight in in Inner Master lb IA 1/2 35C 3004 0.87 300 600 0.1 1711 3/4 35C 3006 0.97 200 400 0.1 � - 1 35C 3010 1.16 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 35BC3-Beam Clamp -.64011111 A Packing Weight in Size 3/8Part Number in Inner Master lb A 14111 35BC3003 0.75 100 200 0.3 M11 1/2 35BC3004 0.75 80 160 0.5 10 Mil SMITH-COOPER INTERNATIONAL° • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 114 Fiyet pa ® C u ' LPCB � LISTED s..-• 491a/27 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating'h,3/4,and 1'/15,20 and 25 mm outlets for directly connecting sprinklers,drop nipples,sprigs,gauges,drains and other outlet products.Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems,Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe.When tightened,the assembly compresses the gasket onto the OD of the pipe.The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall,Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15,is available upon special request. Gasket: • Grade"E"EPDM-Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade"E"Type A Gasket System. Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A483. Housing Coating: • Orange enamel(North America,Latin America,Asia Pacific) • Red enamel(Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt„„ „ IC° REV_G 10,52.1 IPS CARBON STEEL PIPE- HOLE CUT PRODUCT,'. 10.52 FireLock® Outlet-T STYLE 922 DIMENSIONS Nominal Size 1 Hole I Approx. Inches/mmDiameter Dimensions -inches/mlr,mete Weight Each Run X Branch � k0.051a,1.5. ice '�' "�'' FPTt I -0.001-0.0 T= V W V Z lbs/kg 1 PM 1%a Yz 1 3/16 130 1.83 110 3.87 256 1.0 Z� 32 X 15 30.2 33.0 46.5 27.9 98.3 65.0 0 45 V //�� T I :����. -"' 4a 13/16 1.28 1.83 1.10 3.87 2.56 11 1 20 30.2 32.5 46.5 27.9 98 3 65.0 0.50 ,1 �■� VV ■■� 1 13/16 1.52 218 110 3.87 256 12 II ,� I I Vii 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 1'hX h 13/16 142 195 122 4.08 2.56 12 40 15 30.2 36.1 495 31.0 103.6 65.0 054 34 . 13/16. 1.40 1.95 1.22 4.08 2.56 1.2 . 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 13/16 1.64 2.30 122 4.08 2.56 13 25 30.2 417 58.4 31.0 103.6 650 059 2 'h 1 3/16 1.66 2.19 1.46 4.60 2.56 1.3 50 X 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 44 i 1 3/16 1.64 2.19 ---1.46 4.60 256 14 20 30.2 417 55.6 371 116.8 650 0.64 1 1 3/16 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 21/2 X h 13/16 191 2.44 1.71 5.40 256 1.6 65 `15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3/4 1 3/16 : 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 1 3/16 213 - 2.79 '.. 171 5.40 2.56 1.6 25 302 54.1 70.9 43.4 1372 65.0 0.73 76.1 mm X '/z. 13/16 191 2.44 1.71 550 256 1.6 15 : 30.2 485 62.0 43.4 1397 650 0.73 44 13/16 1.89 : 2.44 171 550 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 13/16 2.13 2.79 1.71 5.50 2.56 1.7 25 i 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional) male pipe threads only.Use of male threaded products with special features,such as probes,dry pen- dent sprinklers,etc.,should be verified as suitable for use with this Victaulic product.Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads(dimensions are approximate). www.victaulic.com jctaulid VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.52.2 REV_G IPS CARBON STEEL PIPE-HOLE CUT PRODUCTS 1 0.52 FireLock® Outlet-T STYLE 922 PERFORMANCE Equivalent Length of 1 inch Schedule 40 Steel Pipe(per UL Run Size x Outlet Size 213,Section 16)(C=120)*,FT fotheshmyr ' ' 11/4 X 1 32 25 2.6 1½ 1 8.5 X 40 25 2.6 X 2 1 8.5 50 25 2.6 X 1 21/2 8.5 65 25 2.6 1 8.5 76.1 mm X 25 2.6 *Hazen-Williams coefficient of friction is 120 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED.83 ICtaUlie REV G 10.52 3 FireLock° Outlet-T STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing.Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. • For complete contact information,visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 •CtaUliC3 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.52 Pipe Hangers Fig.200 - "Trimline" Adjustable Band Hanger (B-Line Fig.B317ONF) aITOLco Fig.200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) LISTED Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications s Function: For fire sprinkler and other general piping purposes. Knurled ---� u swivel nut design permits hanger adjustment after installation. �� Features: 44-)11:11,,,, ®, _- • (1/2" (15mm)thru 2" (50mm)) Flared edges ease installation for all pipe `�' types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily �a / B ,' installed around pipe. s For hanger with non-captured nut order Fig. 200S. • (21/2" (65mm)thru 8" (200mm)) Spring tension on nut holds it securely in ''-,,, (,/,' hanger before installation.Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (200mm)) Fig.200-1/2.200-3/t in the USA(UL) and Canada (cUL)for steel and CPVC plastic pipe and Fig.200-1 to 200-2 Fig.200-2'/z to 200-8 Factory Mutual Engineering Approved(FM) (3/4" (20mm)thru 8" (2oomm)). Conforms to Federal Specifications WW-H-171 6 &A-A-1 192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 &SP-58, 400,,„ ,, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel £ materials will be supplied with (2) hex nuts in place of a knurl nut. To ` ;, Order By: Figure number and pipe size ( Designed to meet or exceed requirements of , , FM DS 2-0. Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2" (15) 3/8'-16 31/8 (79.41 25/e (66.7) 11 (5.0) 200-3/4 3/4" (20) 3/8"-16 31/8" (79.41 21/2" (63.5) 11 (5.0) 200-1 1" (251 3/8"-16 33/8" (85.7) 25/8" (66.7) 12 (5.51 200-11/4 11/4" (32) 3/8°-16 33/4' (94.0) 27/8" (73.0) 13 (5.9) 200-11/2 11/2" (40) 3/8"-16 37/8' 198.4) 27/8" (73.0) 14 (6.4) 200-2 2" (501 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 200-21/2 21/2" (651 3/8°-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) 3/8"-16 57/8" 1149.1) 4" (101.6) 29 (13.3) Fig.200S 200-31/2 31/2" (90) 3/8"-16 73/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4' (1001 3/8"-16 73/8" (187.3) 5" (127.0) 35 (16.01 • 200-5 5" 1125) 1/2".13 91/8" 1231.8) 61/4" 1158.7) 66 (30.2) 200-6 6" 1150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"-13 131/8" (333.4) 83/4" (222.2) 136 162.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions B-Line 21 by E1T•N Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig.103) B3205L - Threaded Rod (right& left hand threads) /TL Size Range: 3/8"-16 thru 3"-4 rod Specify Length �lll�l��l Material: Steel .",\Function: Recommended for use as a hanger support in hanger assemblies. TL 111111 Rod is threaded on both shown. available with left and right hand threadsc-specify Fig. B3205L whenorderi Also ,1 1111 A Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain.Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 X'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x'L' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x'L' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) B3205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) 83205-7/8 x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) B3205-1 x'L' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) 83205-11/8 x'1.' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) B3205-11/4 x'L' 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) B3205-11/2 x'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) B3205-13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) ' B3205-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) B3205-21/4 x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) • B3205-21/2 x'L' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) B3205-23/4 x'L' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 x'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR - All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig.100) Fig. 99 -All Threaded Rod Cut To Length "ii0 1111 Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length 'l�hllllhll 1 9 9 9 �p� il Material: Steel ad T. Maximum Temperature: 750°F(399°C) a ni too Finish: Plain. Contact B-Line for alternative finishes and materials. 2 d Order By: Part number, rod diameter and finish 1-a Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"x 120 99-1/4"x length 20 240 (1.07) 12 (5.44) ATR 3/8"x 120 99-3/8"x length 16 730 (3.24) 29 (13.15) ATR 1/2"x 120 99-1/2"x length 13 1350 (6.00) 53 (24.04) . ATR 5/8"x 120 99-5/8"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"x 120 99-3/4"x length 10 3230 (14.37) 123 (55.79) ATR 7/8"x 120 99-7/8"x length 9 4480 (19.93) 170 (77.11) • ATR 1"x 120 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers&Supports 236 Revised 4/28/2014 Line by E_ *111 VERTICAL MOUNT SAMMYS' ° SAMMYS° for Wood Not less than Wood Flooring 2"nominal width Product Features Ak (1-112") - •No pre-drilling required. Not less than •Quick to install using the Sammy 3"nominal Nut Driver with an 18V cordless thickness(2-1/2') i ». (depth or side Wood Joist drill/driver. I of vertical member) ,.. , �" � " .ouAw. I •Saves time from traditional t Double Sheetrock methods. For vertical use- Ceiling !, mstalLinoenteroflowerface. ., •Reduces installation cost. r~ Minimum 2"embedment into base t material for NFPA 13 compliance. t. Composite(Truss •Made in the U.S.A. i01 ti1i. 11 k •Consult truss manufacturer for recommended installation point. ' *Pre-drilling maybe required for GST 3 „, 25380.Tool available on page 10. 1.3 Rod Part Screw Ultimate UL Test FM Test Box Case,"' Approvals Model Size Number Descriptions ,,Pullout Obs Load PO », I-Qad -• e . , •• 1/4" 8002957 GST 100 1/4 x 1" 210 (7/16 OSB) 25 125 670 (3/4"Ply) 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 1/4" 8004957 GST 300 1/4 x 3" 2060(Fir) 25 125 3/8" 8006957 GST.75 1/4 x 3/4" 564 (3/4"Ply) 25 125 Q,, 3/8" 8007957 GST 10 1/4 x 1" 210(7/16"OSB) 300 25 125 670(3/4"Ply) _ Ili -°,0 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 Q. 3/8" 8068925 GST 20-SS 1/4 x 2" 1760 (Fir) 850 25 125 3/8" 8009925 GST 25-380 3/8x2-1/2" 2113 (Fir) 1500 25 125 0 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) 1500 1475 25 125 #14 Black Nut Driver 3/8" 8069925 GST 30-SS 1/4 x 3" 2060 (Fir) 25 125 Part#8113910 3/8" 8011925 GST 40 1/4 x 4" 2180 (Fir) 25 125 3/8" 8012925 GST 60 1/4 x 6" 2230 (Fir) 25 125 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25 125 1/2" 8014925 GST 2.5-380 3/8 x 2-1/2" 2113 (Fir) 25 125 1/2" 8015925 GST 3 1/4 x 3" 2275 (Fir) 25 125 — 0,4 1/2" 8016925 GST4 1/4x4" 2180 (Fir) 25 125 1/2" 8017925 GST 6 1/4 x 6" 2230(Fir) 25 125 _ #14 SW Red Nut Driver Part#8114910 SAMMY Swivel Head°for Wood 17° in wood struciuiu Product Features •Eliminates distortion of threaded rod. •Saves time from traditional methods. s� •Accommodates up to 3'/:"x 12 pitch roof. •Reduces installation cost. •Allows 17°deflection from vertical. •Made in the U.S.A. Rod Part Screw Ultimate UL Test FM Test Min Box Case Approvals Model p (lbs) (lbs) (lbs) Qty Qty, *¢,It Size Number Descriptions Pullout lbs Load lbs Load lbs Thickness 4 €' 3/8" 813995 ` 'r"71«`',,,',1 MTa '' 1257(Fir) 1050 1475 25 125 125 3 3/8" 8141957 SH-GST 30 1/4 x 3" 1720(Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into Part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information,visit www.sammysuperscrew.com 4 `--; V HS WOxaauL