Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (62)
Lckss ccx,ciVAJA . . 4MN " COMPLETE SECURITY SOLUTIONS HE(.;hivhii SEP i 2019 ,0- REECE COMPLETE SECURITY SOLUTIONS CORPORATE HEADQUARTERS PRODUCT DATA SUBMITTAL FIRE ALARM SYSTEM cp I TEL:503.682.9900/FAX:503.682.9500/25977 SW Canyon Creek Road.,Suite E/Wilsonville,OR 97070/Web:RCSS.us/CCB#67147 COMPLETE SECURITY SOLUTIONS" REECE COMPLETE SECURITY SOLUTIONS CORPORATE HEADQUARTERS FIRE ALARM SYSTEM PRODUCT DATA SUBMITTALS INDEX Mfq. Model Description • Knox Company KnoxBox 3200 High-Security Key Lock Box • Power-sonic PS-1270 12 Volt 7.0 AH Battery • Silent Knight 5860R Remote Annunciator • Silent Knight 5880 10/LED Driver Module • Silent Knight 5883 Relay Interface Module • Silent Knight 6808 Addressable Fire Alarm Control Panel • Silent Knight CELL-CAB-SK Cellular Fire Alarm Communicators • Silent Knight OSI-RI-SK Beam Smoke Detector • Silent Knight SK-DUCT Intelligent Air Duct Smoke Detector • Silent Knight SK-HEAT-W Intelligent Thermal (Heat) Detector • Silent Knight SK-PHOTO-W Intelligent Photoelectric Smoke Detector • Silent Knight SK-PULL-DA Intelligent Pull Stations • Silent Knight SK-RELAY Intelligent Relay Module • System Sensor P2WL/SWL Horn Strobe/Strobe Wall-Mount • System Sensor RTS151KEY Remote Test Station w/Key • System Sensor SWK Weatherproof Strobe Wall-Mount TEL 503.682.9900/FAX 503.682.9500/25977 SW Canyon Creek Road.,Suite E/Wilsonville,OR 97070/Web:RCSS.com/CCB#67147 [C) KNOX® v Ir 'r ya 3200 When seconds matter`" The KnoxBox 3200 is the number one high-security key lock box trusted by first responders and property • owners. Store up to 10 keys to quickly gain rapid access to commercial properties. FEATURES v Stores maximum 10 keys.Access cards and small entry Available in 3 colors: items may also fit in interior compartment but will reduce s r, III III • max key quantity. " r- ; Black Aluminum Dark o Built Knox-Rugged and secure: UL 1037, UL 1610, ' Bronze UL 1332, UL 437 { se Finished with Knox-Coat®to protect four times better than standard powder coat v Weather-resistant door gasket 4 `` ,,,,, Hinged door - t .Tl [ BENEFITS'' ,x �,,. v Allows rapid property access Recessed Mount Reduces property damage v Prevents forced entry into buildings Surface Mount a �t v Minimizes first responder injury se Compliant to National Fire Code(NFPA, IFC, IBC) WEIGHT: DIMENSIONS: OPTIONS Surface Mount 8 lbs Surface Mount Body-4"H x 5"W x 3-7/8"D v Knox Tamper Alert connects to building's alarm system Recessed Mount-9 lbs Recessed Mount Flange-7"H x 7"W for extra security v Mount types: Recessed and Surface SURFACE MOUNT-FRONT VIEW v 3 color options: Black,Aluminum, Dark Bronze — ACCESSORIES Heavy 1/8"thick Stainless steel rill door hinge V Multi-Purpose Switch for use on electrical doors, gates stainless steel p lock cover and other electrical equipment l '0 Recess Mounting Kit for new concrete or masonry construction Hole for I l I tamper seal •., Public Safety Labels 1/2"solid plate Tag-Out Tamper Seals steel door with gasket v Key Tags '--..1/4"sold steel housing O KeyRings 100%welded g ORDERING SPECIFICATIONS RECESS MOUNT-FRONT VIEW SIDE VIEW To insure procurement and delivery of the KnoxBox 3200, it 7"WIDE 3"DEEP--- is suggested that following specification paragraph is used: KnoxBox surface/recessed mount with hinged door, with/without 1/4"steel case, / \ 100%welded UL Listed Knox Tamper Alert. 1/4" plate steel housing, 1/2" / thick steel door with interior gasket seal and stainless steel door - hinge. Box and lock UL Listed. Lock has 1/8"thick stainless steel dust cover with tamper seal mounting capability. H 3H © Exterior Dimensions: Surface Mount Body-4"H x 5"W x 3-7/8"D Recessed Mount Flange-7"H x 7"W i_I Lock: UL Listed. Double-action rotating tumblers and hardened steel pins accessed by a biased cut key. - \\_\":.2..._______ Flange Finish: Knox Coat proprietary finishing process z,Eeam n � (recessed 7"x 7"flange �` H model only) (recessed Color: Black, Dark Bronze or Aluminum model only) �IS1Fp P/N: KnoxBox 3200(mfr's cat. ID) EQUIPMENT y 3-7/8" Mfr's Name: KNOX COMPANY CE --------------------- -------------------------------------------------- 1601 W. DEER VALLEY RD. PHOENIX,AZ 85027 I T.800-552-5669 I F.623-687-2290 I INFO@KNOXBOX.COM I KNOXBOX.COM c-Knox Company.All rights reserved. MKT-KBSPEC-0019-E IIE KNOX® KNOXBOX' 3200 When seconds matter" GENERAL MOUNTING INSTRUCTIONS ATTENTION: KnoxBox is a very strong device that MUST be mounted 1 Suggested minimum mounting height, properly to ensure maximum security and resist physical attack. 6 feet above ground. Inside View " Large Optional thick 5 rear Knox steel -� 7/8" 3-1/4" 7/8" t Tamper Alert washer —.- 3/4„ -- 3/4„r- mill Rear Knox / \ 7/8 Tamper Alert hole / Key Hook_— ll'110800=MMM•1111111111H1 c — 0fr X 2-5/t6„ OTo building alarm system hinge OptinalDoor-� • Tobuiodoor nal alarm 1-1/8" Tamper Alertsystem 2.,0000000— ' Door ` \ J 3/8"Grade 5 or j \ / Grade 8 fastener All mounting Alarm wire holes are 7/16" exit opening Holes marked"x"are -- Solid diameter.For used for mounting with Solid concrete wall----- Flange--- concrete mounting use - Rear Knox at least 3/8"Grade 5 or wall at least 3/8" Tamper Alert Grade 8 fasteners Grade 5 or Grade 8 mounting holes KnoxBox 3200 Hinged KnoxBox 3200 Hinged fasteners Door Surface Mount Door Recess Mount RECESS OUNTING KIT AND INSTALLATION INSTRUCTIONS The Recess Mounting Kit(RMK) includes shell housing and mounting hardware, RECESS MOUNTING - which may only be used for recessed models to cast-in-place within new concrete KIT DIMENSIONS or masonry construction.The KnoxBox is mounted into the shell housing after Rough-in Dimensions: construction is completed. 6-1/2"H x 6-1/2"W x 5"D Recessed Mounting RMK shell is Using Recess \ mounted in wall Mounting Kit(RMK) \ during new construction KnoxBox mounts inside Knockouts for RMK shell after alarm wire conduit completion of construction ,''p. I Trim rebar IMPORTANT: for tie-in �� f,�!J� Care should be taken to ensure the front of the II _ x kt.. � to wall if U— Recess MountingKit (RMK) shell housing, including \ / i necessary ,i i the cover plate and screw heads, is flush with the 0�; wall. The RMK must be plumbed to ensure vertical �r.\\\ N 0 alignment of the box. Recessed \ I 4 Flange \ Mounting studs ' Concrete or \ provided inside RMK shell masonry wall-, \\\ to accommodate construction KnoxBox ABOUT KNOX COMPANY Over forty years ago, a unique concept in rapid access for emergency response KNOX COMPANY was born. The KnoxBox'T, a high-security key lock box, was designed to provide 1601 W. DEER VALLEY RD rapid access for emergency responders to reduce response times, minimize PHOENIX, AZ 85027 injuries and protect property from forced entry. T. 800.552.5669 Today, one revolutionary lock box has grown into a complete system providing F. 623.687.2290 rapid access for public safety agencies, industries, military, and property KNOXBOX.COM owners across the world. The Knox Company is trusted by over 14,000 fire INFOCKNOXBOX.COM departments, law enforcement agencies, and governmental entities. 7WEC/! PCl4A"�©C W ` .'. TRUSTED BATTERY SOLUTIONS "'. CL. elp.' a Fr rr ,•, _.. ...5w'" rv$m...5 ..«. ,. SAA r Purpose General light gengy Medical Securre iter y ,, ', � t 1 5 1 7 F r �, 1, ,mrn jl FEATURES ps_1270 12V 7.0 AH @ 20-hr. • Absorbent Glass Mat(AGM)technology for 12V 6.5 AH @ 10-hr. superior performance Rechargeable Sealed Lead Acid Battery • Valve regulated,maintenance free spill proof construction General Purpose Series • Power/volume ratio yielding excellent energy density TERMINALS:(mm) • Rugged vibration and impact resistant ABS case and cover Fl: Quick disconnect tabs, F2: Quick disconnect tabs, 0.187"x 0.032"-Mate with 0.250"x 0.032'-Mate with y • Gas recombination technology AMR INC.FASTON"187"series AMP INC FASTON"250"series • 5 year design life Al 14----2.5 ___..1 IF---2.5 I, ► 'i_*.,, 1 4' 2 APPROVALS En tom' `^ OR ==-i ' 3.2(. + • Approved for transport by air.D.O.T.,I.A.T.A.,F.A.A. +46.35 0.''. -. 3.4 14-- l and C.A.B.certified 4 7.95 •.I ..:Orf, 55..1.........''5 • nvvw • }� i • U.L.recognized Torque-Not Applicable Torque-Not Applicable • IS09001:2015-Quality management systems DIMENSIONS:inch(mm) PERFORMANCE SPECE5 '-- ' L: 5.95(151) Nominal Voltage 12 volts(6 cells) 1,-131112 W: 2.56(65) - Et H: 3.70(94) Nominal Capacity W HT: 3.86(98) 20-hr. (350mA to 10.50 volts) 7.00 AH Tolerances are+/-0.04 in. 10-hr. (650mA to 10.50 volts) 6.50 AH (+/-1 m )and 0t08 is (+/-2mm)for height 5-hr. (1.2A to 10.20 volts) 6.00 AH dimensions.All data subject 1-hr. (4.5A to 9.00 volts) 4.50 AH to change without notice. Approximate Weight 4.80 lbs (2.18 kg) r- - la al ��� - Internal Resistance(approx.) 23.0 milliohms P WER Max Short-Duration Discharge Current(10 Sec.) 70.0 amperes wic MODEL PS 1270HT 55 votes• H ! Shelf Life(%of nominal capacity at 68°F(20°C) 1 Month 97% X(.',) 3 Month 91% 6 Month 83% I L '{ Operating Temperature Range Charge 5"F(-15°C)to 122°F(50°C) Discharge -4°F(-20°C)to 140°F(60°C) CORPORATE HEADQUARTERS POWER-SONIC EUROPE LIMITED Case ABS Plastic (USA AND INTERNATIONAL EXCLUDING EMEA) (EMEA-EUROPE,MIDDLE EAST AND AFRICA) Power-Sonic Corporation 3 Buckingham Square, Power Sonic Chargers PSC-12800A-C 7550 Panasonic Way,San Diego, Hurricane Way,Wickford, PSC-121000-PC California 92154 Essex SS11 8YQ T: +1(619)661 2020 T: +44(0)1268 560686 t F: +1(619)661 3650 F: +44(0)1268 560902 a t - E: customer-service@power-sonic.com E: salesEMEA@power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technca:Manual,as published on our website rs 2018.Power Sone Corporal All rights reserved.All trademarks are the p-operty of their respective owners. All data subject to change without noticepO W @ C-SOn(C.CO nl .580.E n H tart Pl.7WERA SONIC ti TRUSTED BATTERY SOLUTIONS N O. PS-1270 12V65AH@10-hr. Rechargeable Sealed Lead Acid Battery PS - General Purpose Series SHELF LIFE&STORAGE LIFE CHARACTERISTICS IN STAND-BY USE 100Charging is not Ambient Temperature 20°C(68'F) cnecessary unless 100 i I i I 100%of capacity O Is required. 'a-. 80 80 -5°C Charging before C use is necessary 60 - o (41°F)— to help recover full capacity. Float Charging Voltage y▪ 60 40 2.25-2.30 V/Cell a _ 1 re40°C 30°C Y0°C 20 Z' 40 (104°F) (86°F) (68°F) 0 tz CL r 0 1 2 3 4 5 m 0 0 0 2 4 6 8 10 12 14 16 18 20 Years Standing Period(Months) CHARGING CHARGERS Cycle Applications:Apply constant voltage charge at Power Sonic offers a wide range of chargers suitable 2.35v/c—2.45v/c(14.1 — 14.7v for 12v Monobloc)at 20°C. for batteries with a variety of capacities. Initial charging current should be set at less than 0.25C Please refer to our website for more information on Amps.Switch to float charge to avoid overcharging. our switch mode and transformer type chargers. "Float"or"Stand-By"Service:Apply constant voltage Please contact our technical department for advice if charge of 2.25v/c—2.30v/c(13.5 to 13.8 volts for 12v you have difficulty in locating a suitable charger. Monobloc at 20°C.When held at this voltage,the battery will seek its own current level and maintain itself in a fully FURTHER INFORMATION charged condition. Temperature Compensation:Charging Voltage for both Please refer to our website www.power-sonic.com Cyclic and Standby applications should be regulated in for a complete range of useful downloads,such as relation to ambient temperature.As temperature rises product catalogs,material safety data sheets(MSDS), charging voltage should be reduced to prevent overcharge ISO certification,etc. and increased as temperature falls to avoid undercharge. For further charging information including temperature .... compensation factors,see Power Sonic Technical Manual/ _ h.„ Power Sonic Charger specifications. APPLICATIONS • General purpose « Medical l') ~ * Emergency lighting • Fire and security PC,wE „} (G :, rt+rw.waca�ae»*!ax•"""'oas.€tw,+° s n CORPORATE HEADQUARTERS POWER-SONIC EUROPE LIMITED • f;l •a ° (USA AND INTERNATIONAL EXCLUDING EMEA) (EMEA-EUROPE,MIDDLE EAST AND AFRICA) Power-Sonic Corporation 3 Buckingham Square, 7550 Panasonic Way,San Diego, Hurricane Way,Wickford, California 92154 Essex SS11 8YQ T: +1(619)661 2020 T: +44(0)1268 560686 F: +1(619)661 3650 F: +44(0)1268 560902 i. E: customer-service@power-sonic.com E: salesEMEA@power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual,as published on our website. A 2018.Power-Some Corporator.Ail rights reserved.All trademarks are the property of their respective owners. poww�� O •�O All data subject to change without notice E80.E �+ Honeywell cG SILENT' KNIGHT 5860 Remote Annunciator The 5860 remote annunciator,can be used to operate and program 3?. Honeywell Silent Knight fire alarm control panels(FACPs)from anywhere within the system. tm" 11 „n • The 5860 features include an 80-character backlit LCD providing easy-to 1004 understand system messages.The annunciator is ergonomically designed $ "`"' u._ yrif A with over-sized buttons for the most frequently used features,like Reset and Silence. ,, arI ` 11111* In addition to status messages displayed on the LCD,there are five LEDs for alarm,supervisory,trouble,silence,and AC power status. The 5860 annunciator is available in gray to match virtually any decor and 5860/58608 red for applications where the annunciator must stand out.The annunciator enclosure can be surface or flush mounted.A trim ring kit is available for surface mounting. COMPATIBILITY The 5860 is compatible with the following Honeywell Silent Knight FACPs: 6820:Addressable fire alarm control panel with up to 1,110 addressable points 6820EVS:Addressable fire alarm control panel with an emergency communication systems and up to 1,110 addressable points 6808:Addressable fire alarm control panel with up to 198 addressable points 6700:Addressable fire alarm control panel with up to 100 addressable points 5820XL:Addressable fire alarm control panel 5820XL-EVS:Addressable fire alarm control panel with an emergency communication systems 5808:Addressable fire alarm control panel 5700:Addressable fire alarm control panel I C 80 k huracter backlit • Support for • Five Status LEDs • Accommodates wiring « Acct} rcte:; LCD display(4 lines simultaneous use of Available in red or light lengths up to 6000 ft. fire fighter's key •with 20 characters per multiple 5860s color from the control panel line) gray for added design and Larger" keypad buttons • Easily view currentmakes it easier to install flexibility • Tactile/audible status by alarms, maneuver for system feedback when a key is supervisories,or reset and silencing pressed on the troubles annunciator • Uses the RS-485 SBUS to interface with the panel 5860 Technical Specifications For a complete listing of all compliance approvals and certifications.please visit www.silentknight.com. Microsoft,Windows,and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Wire Runs Up to 6000 Feet From FACP Silent Knight'and "" ' Honeywell"are registered trademarks of Honeywell ION MIN MIN nternational,Inc. SBUS ,: gP+amio. iii This document is not ��,. ..;.✓s.miii intended to be used for 5860 5860 5860 installation purposes.We try to keep our product •Up to Eight 5860s Per 5700 or 6700 System information up-to •Up to 12 5860s Per 5808,6808,5820XL,or 5820XL-EVS System date and accurate.We •Up to 16 5860s per 6820 or 6820EV5 System cannot cover all specific Compatible Silent Knight FACP applications or anticipate all requirements.All specifications are subject to change without notice. For Technical Support, 5860 Features call 800 446 6444 PHYSICAL ORDERING INFORMATION Dimensions:9.1"W x 7.4"H x 1.5"D(23.1W x 18.8H x 5860:Remote Annunciator,four line(4x20)LCD 3.8D cm) annunciator with 20 characters per line.Gray Shipping Weight:2.8 lbs(1.3 kg) 5860R:Remote Annunciator.four line(4x2.0)LCD Color:5860R:Red:5860:Gray annunciator with 20 characters per tine.Red ENVIRONMENTAL ACCESSORIES Operating Temperature:32°F to 120°F(0°C to 5860TR:Red trim Ring for surface mounting 49°C) 5860TG:Gray Trim Ring for surface mounting Humidity:10°/o-93%non-condensing) AGENCY LISTINGS AND APPROVALS ELECTRICAL UL listed Operating Voltage:24VDC CSFM approved Standby Current:20mA Meets NFPA 72 requirements Alarm Current:25mA FM approved MEA approved For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 Doc 3502241 RevJ 12/17SILENT' 800-328-0103 2017 Honeywell International Inc. ®KNIGHT -----"41111194 , Honeywell ril SILENT' Ilii KNIGHT 5880 10 / LED Driver Module The 588010/LED Driver module provides an effective means toy.iihrii customize your remote annunciation. „v b AirF , J r pf vyc, gg, A single 5880 provides 40 programmable LED outputs and eight MODELsew ,:¢ .i B„., supervised dry contact inputs.You can use up to eight 5880 modules on IgitakiiWi 0 G one FACP for maximum flexibility.The 5880's compact size allows for .« (0) 44 t4M4titAttRA mounting inside a remote graphic annunciator or in an accessory cabinet. 6 0 i COMPATIBILITY 0” 1400100 � 8 �� ting la014. 0� The 5880 is compatible with the following Honeywell Silent Knight fire 6" alarm control panels: „i� lar ,„, " 400064450,100001150.011110 6820:Addressable fire alarm control panel 6820EVS:Addressable fire alarm control panel with an emergency voice ` system. 5880 6808:Addressable fire alarm control panel 6700:Addressable fire alarm control panel 5700:Addressable fire alarm control panel 5808:Addressable fire alarm control panel 5820XL:Addressable fire alarm control panel 5820XL-EVS:Addressable fire alarm control panel with an emergency voice system. • 40 ' ogrammable • No external resistors • UL 864 listed: • uulIvitifiiitry mappedYuu uon;ase up Go open collector LED required for the 5880 complies with NEPA outputs eight 5880 modules outputs LED driver outputs 72 • Inputs for dry contacts on one control panel • Provides 8 supervised • DIP switch • MEA 429-92-E,Vol.9 or a remote silence or for maximum drycontact inputs for addressable flexibility p • FM approved reset switch system or alarm • 4.-wire connection to monitoring functions • £'SEM listed control panel S£3U5 • Its compact size allows mounting ' inside the annunciator, or in an accessory cabinet 5880 Technical Specifications z � i For a complete listing of all ' 1 compliance approvals and certifications,please visit www.sitentknight.com or . J S . Microsoft, trademarks Windofows,and the Windows Logo are registered trademarks 7-314' F �} Microsoft Corporation. Silent Knight'',System ;�x Sensor and Honeywell`s o o are registered j o trademarks of Honeywell International,Inc. This document is not 6„ intended to be used for installation purposes.We Reset try to keep our product Switch information up-to 1-15116" ,acr m date and accurate.We cannot cover all specific applications or anticipate all requirements.All PHYSICAL ORDERING INFORMATION specifications are subject to change without notice. Mounting:in annunciator or accessory cabinet 5880:LED 10 module has 40 programmable LED outputs and eight supervised dry contact inputs For Technical Support, ENVIRONMENTAL which are usefutfor custom applications. call800-446-6440. Operating Temperature:32°F to 120°F(0°C to 49°C) AGENCY LISTINGS AND APPROVALS Humidity:10 to 85%non-condensing) NEPA 72 UL 864 Listed ELECTRICAL CSFM:7165-0559:0502; Operating Voltage:24VDC MEA:429-92-E Vol 9 Standby Current:35mA FM approved Alarm Current:200mA LED:10mA For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 Doc 350233 Rev F!05/18 SILENT 800-328-0103 tit 2018 Honeywell International Inc 111641KINIGHT Honeywell SILENT' KNIGHT 5883 Relay Interface Board The 5883 Relay Interface Board provides 10 general purpose Form C relays that can be used to control any device that requires a dry contact closure. The interface board is activated by an open collector input from a it 111. controlling device such as a 5880 LED Driver Module. The 5883 is housed in a durable metal cabinet that provides room for system wiring.The cabinet comes complete with lock and key to prevent " 0 U $ t, .*$l.$1*41 4+.3 t,t " unauthorized access. - ' �`� ° ' �" ' � `'•. COMPATIBILITY The 5883 is compatible with the following Honeywell Silent Knight FACPs: 6820:Addressable fire alarm control panel * * 6820EVS:Addressable fire alarm control panelwith an emergency mass • notification system. 6808:Addressable fire alarm control panel 5883 6700:Addressable fire alarm control panel • 5700:Addressable fire alarm control panel. 5808:Addressable fire alarm control panel 5820XL:Addressable fire alarm control panel 5820XL-EVS:Addressable fire alarm control panel with an emergency mass notification system r Lt\ ( LSP `�U � � IrI�JLi • 10 general purpose • Controls any dry • UL listed to 864 Form C relays contact device standards • Relays rated at 5.0A • Housed in protective Ca-30 VDC or 2.50 cabinet VAC resistive • 5883 Technical Specifications 10-3/8" For a complete listing of all compliance approvals and certifications,please visit www.sitentknight.com. Microsoft,Windows and the Windows Logo are registered trademarks or trademarks of U " " " " Microsoft Corporation. � Silent Knight'and Honeywell are registered sr't SZi< t e e <a;t < s e < < trademarks of Honeywell International,Inc This document is not 10-1/8" / intended to be used for installation purposes.We try to keep our product information up-to date and accurate.We cannot cover allspecific applications or anticipate all requirements.All specifications are subject to change without notice. /7/41.. For Technical Support,Please call 800-446 6444. 5883 DIMENSIONS PHYSICAL ORDERING INFORMATION Cabinet Dimensions:101/8"H x 10-3/8"W x 3 1/8" 5883:Relay Interface Board D(26.04x26.35x7.94CM) AGENCY LISTINGS AND APPROVALS ENVIRONMENTAL • CSFM Operating Temperature:32°F-120°F(0°C-49°C) Humidity:10%-85% • UL Listed Indoor use only • City of NY:429-92-E Vot XI ELECTRICAL Operating Voltage:24VDC Form C Relay:5A cs 30VDC or 250VAC resistive Current: Standby:OmA Alarm:220mA(22mA/Relay) For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com H K Silent dight Honeywell 12 Clintonville Road Northford,CT 06472 Doc 350311 Rev E111/17 SILENT' 800-328-0103 2017 Honeywell International Inc Nal KNIGHT • Honeywell I Addressable Fire Alarm Control Panels 0 SILENT' IwICIT 6808 Accressable Fire Alarm Control Panel The 6808 is an addressable fire alarm control panel(FACP)that is a direct replacement for the 5808 FACP.The 6808 can be configured to achieve a point capacity of 198 points.It has one built-in signaling line circuit(SLC),which can support 99 System Sensor'(SK)sensors and 0 99 SK modules or 127 Hochikix(SD)devices per loop. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable.A designated panel is configured as the communicator for all panels in the link for convenient single-point communications.It also has a built-in,dual- line POTS and IP communicator with additional cellular options available. 6808 The 6808 system can be enhanced by adding modules such as the The supports a variety of devices,including the 6860 remote annunciator which also has four programmable function 6860,5860,and 6855 remote annunciators,5824 buttons to help automate tasks and reduce time spent at the panel. serial parallel printer interface module(for printing system reports),the 5496 NAC expander,5895XL SWIFT`'wireless compatibility provides options for wireless detection power module,and SK or SD devices. through a Class A mesh network.It is ideal for hard-to-wire locations, buildings where new wiring is not allowed,or to provide an easy install fire system for new construction projects.SWIFT devices can be combined with other hard-wired 6808 compatible devices. The 6808 also has a form-C trouble relay,two programmable form-C relays,along with powerful features such as drift compensation,pre- trouble maintenance alert,a built-in sensor test to comply with NFPA 72 calibration testing requirements,and calibration trouble alert. • Capable of providing • Convenient • 6860 annunciator with • Programmable date • .125 software zones up to 198 points to field-upgradeable a 4 x 40 large display setting for automatic and 125 output satisfy smaller firmware • Four user- and convenient groups for flexible installation needs • Built-in dual path programmable buttons Daylight Saving Time design options • Connect up to 17 POTS and IP minimize time spent changes panels on one site with communications with executing complex or • Jumpstart auto convenient single- optional cellular routine tasks programming reduces point access using the models available for • Built-in USB interface installation time SK-NIC Network reliable backup for convenient and Interface Card. reporting Connected panels can quick programming have mixed compatible FACP models SIGNAL LINE CIRCUIT(SLC) PROGRAMMING ORDERING INFORMATION The 6808 SLC loop supports multiple The 6808 system offers several options 6808:Addressable Fire Alarm device types,maintenance alerts,and a to simplify and speed-up programming. Control Panel.(Red cabinet). - built-in sensor test to comply with NFPA JumpStart"auto programming 72 calibration testing requirements. minimizes programming required to start COMPATIBLE ANNUNCIATORS a new system.The built-in keypad,or the 6860:4x40 LCD remote fire INDICATOR LIGHTS 6860,5860 or 6855 remote annunciator(4 tines and up to • General Alarm(Red):Flashes if in annunciators give you on-site access to 160 characters)per system;four alarm;solid when alarm is silenced current system programming. programmable buttons • Supervisory(Yellow):Flashes if a Programming can also be accomplished 5860:4x20 LCD remote fire supervisory condition exists:solid using the Windows"-based Honeywell annunciator.5860 is gray;5860R is red when supervisory is silenced Fire Software Suite(HFSS)program. 6855:4x20 LCD remote fire • System Troubles(Yellow):Flashes annunciator SOFTWARE TOOLS if a trouble condition exists; 5865-3 or 5865-4:LED annunciators SKST:Silent Knight Selection Toot solid when trouble is silenced can display up to 30 LEDs(15 red and provides the installer or design architect 15 yellow).The 5865-4 has key switches • System Silenced(Yellow): with a Windows''software system for silence and reset,and a system On when an alarm,trouble or configuration tool to create a detailed Bill supervisory condition has been trouble LED. P Y of Material(BOM)and battery 5880:LED/10 module has 40 silenced but not yet cleared calculations. programmable LED outputs and eight • System Power(Green):Flashes HFSS:Honeywell Fire Software Suite supervised dry contact inputs which are for AC failure;solid when provides communication and panel useful for custom applications.You can power systems are normal programming,detector status,event use up to eight 5880 modules on one history and additional data.Requires a control panel for maximum flexibility. INTERFACE p PC running Microsoft" Windows'. Its compact size allows mounting inside The 6808 built-in 4 x 20 annunciator with 80 character LCD display ADDITIONAL INFORMATION the annunciator,or in an accessory and large easy-to-use tactile Twisted-unshielded pair cabinet. touchpad can be used for system wire is recommended. 6808 COMPATIBLE DEVICES AND operation,programming and The 6808 also has 13 preset notification ACCESSORIES maintenance.It has five LEDs forcadence patterns See the data sheets listed below for a alarm,supervisory,system trouble, complete listing of the SK,SD or SWIFT (including ANSI 3.41). devices. system silenced and system power. 53623:SK Devices Data Sheet AGENCY LISTINGS AND APPROVALS System operations include silencing 53624:SD Devices Data Sheet NPFA 13,NFPA 15,NFPA 16,NFPA 70, 350614,350616&3506.18:SWIFT alarms and troubles,resetting alarms NFPA 72:Central station;remote wireless devices and the display of alarm troubles and Signaling;Local Protective Signaling For a complete and current listing of memory.The system's non-volatile Systems;Auxiliary Protected Premises compatible devices and accessories,visit www.silentknight.com. event history buffer stores 1,000 Unit;Water Deluge releasing service. Important:You cannot mix SK and SID events for viewing from the built, Suitable for automatic,manual, devices in the same fire alarm system. in or remote annunciator.System waterflow,sprinkler supervisory(DACT operations can be initiated with a non-coded)signaling services mechanical firefighter's key or a • UL Listed:S2766 valid 4-to 7-digit operator's code. • CSFM:7165-0559:0502 • FDNY:COA#6246 • FM approved Page 2 of 4—351608:8 9/26/2018 SK COMPATIBLE ADDRESSABLE B200S-LF(-IV,-WH):Low-Frequency WSK-WGI:Wireless Gateway DEVICES intelligent sounder base WSK-PHOTO:Wireless Photoelectric smoke SK-ACCLI MATE:Multi criteria B200S-LF:Low-frequency intelligent detector photoelectric smoke detector with thermal sounder base WSK-PHOTO-T:Wireless Multi-criteria 135°F fixed temperature B224RB(-IV,-WH):Relay base photoelectric smoke detector with thermal SK-BEAM:Reflected beam smoke detector B224RB: Relay base detection(135°F fixed temperature)and without test feature B224131(-1V,-WH):Isolator base B510W 4"base SK-BEAM-T:Reflected beam smoke B224B1: Isolator base WSK-HEAT:Wireless Heat,(135°F fixed detector with test feature temperature)and B510W 4"base SK-CONTROL:Supervised control module SD COMPATIBLE ADDRESSABLE WSK-HEAT-ROR:Wireless heat,ROR SK-CONTROL-6:Six circuit supervised DEVICES (135°F fixed temperature)and B510W 4" control module SD505-6AB:Addressable 6"base base SK-DUCT:Photoelectric duct smoke SD505-61 B:Addressable 6"short circuit WSK-MONITOR:Wireless monitor module detector with extended air speed range isolator base WSK-RELAY:Wireless relay module SK-FIRE-CO:Four criteria fire and carbon SD505-6RB:Addressable 6"relay base W-USB:SWIFT Tools USB transceiver used monoxide detector SD505-6SB:Addressable 6"sounder base for communication with SWIFT devices SK-HEAT:Fixed thermal detector(135°F) SD500-AIM:Addressable input module SK-HEAT-W:Fixed thermal detector (switch input) SOUS ACCESSORIES (135°F).white SD500-ANM:Addressable notification 5496:A 6 amp notification power expander SK-HEAT-ROR:Fixed rate of rise detector module with four power-limited notification (135°F) SD500-ARM: Addressable relay module appliance circuit outputs. SK-HEAT-ROR-W:Fixed rate of rise SD505-DTS-K: Remote test switch and 5883:Relay Interface.Provides 10 Form C detector(135°F),white LED indicator for the SD505--DUCTR relays. SK-HEAT-HT:Fixed high temperature SD505-DUCT:Addressable Duct Smoke 5824:Serial/Parallel Printer Interface thermal detector(190°F) Detector. Module for printer connection. SK-HEAT-HT-W:Fixed high temperature SD505-DUCTR:Addressable Duct 5895XL:Power Supply with six Flexput''" thermal detector(190°F),white Detector housing with relay base. circuits,and two Form C relays.Max.16 per SK ISO:Fault isolator module SD505-H EAT:Absolute temperature heat system. SK-MINIMON:Mini monitor module detector.Trip point range from 5815RMK:Remote mounting kit. - SK-MONITOR:Monitor module 135°F--150°F(0°C-37°C). Dimensions:10 3/8"W x 10-3/1.6"H x 3"D SK-MONITOR-2:Dual input monitor SD500-LIM:Addressable Line isolator COMMUNICATION OPTIONS module module SK-MON-10:10 input monitor module SD500-MIM:Addressable Mini input CELL-CAB-SK:Cellular communicator, SK-PHOTO:Photoelectric smoke detector monitor module(switch input) metal enclosure with lock/key* SK-PHOTO-W:Photoelectric smoke SD505-PHOTO:Photoelectric smoke CELL MOD:Cellular communicator,plastic detector,white detector enclosure* SK-PHOTO-T:Photoelectric smoke detector SD500-PS/-PSDA:Addressable Single or *Sole path,powered by panel. with thermal(135°F fixed temperature) dual action pull station I PGSM-4G:Dual path fire alarm SD500-SDM:Addressable smoke detector communicator,cellular and/or IP(primary or SK-PHOTO-T-W:Photoelectric smoke backup,with thermal(135°F fixed module s electable) temperature),white SK-IP-2:Remote reporting via the Internet. SK-PHOTOR:Photoelectric detector with AUDIBLE/VISIBLE DEVICES Requires a VisorAlarmO°receiver at the central remote test capability These AV devices are all 2-wire.Color:"R" station SK-PHOTO-R-W:Photoelectric detector indicates red;"W"denotes white.For a MISC.ACCESSORIES with remote test capability,white complete listing of Silent Knight AV devices SK-NIC:Network Interface Card.Provides a SK-PULL-SA:Addressable single action go to www.silentknight.com. common communications link for the 6808. pull station CHSRL/CHSWL:Wall chime/strobe SK-NIC-KIT:Installation AccessoryKit SK-PULL-DA:Addressable dual action pull CHSCRL/CHSCWL:Ceiling chime/strobe station CHRL/CHWL:Walt chime SK-FML Fiber-Optic Multi Mode, SK-RELAY:Addressable relay module transmitter and receiver HRL/HWL:Wall horn SK-FSL:Fiber-Optic Single Mode SK-RELAY-6:Addressable Six relay control P2RL/P2WL:Wall horn/strobe p gi module RBB:Remote battery box accessory cabinet PC2RL/PC2WL:Ceiling horn/strobe for batteries that are too large to fit in the SK RELAYMON 2:Addressable Dual SRL/SWL:Wall strobe FACP cabinet.Dimensions:16"W x 10"H x relay/monitor module SK ZONE:Addressable zone interface SCRL/SCWL:Ceiling strobe 6"D(406mm W x 254mm H x 152mm D). module SPSCRL/SPSCWL:Ceiling speaker/strobe SK-SCK:Seismic Compliance Kit used to SK-ZONE-6:Six zone interface module SPSRL/SPSWL:Wall speaker/strobe securely fasten batteries to the fire panel. B300-6(-IV):6"base for SK-W Series SPRL/SPWL:Wall speaker B210LP:6"mounting base SPCRL/SPCWL:Ceiling speaker B501(-BL,-IV,-WHITE):4"flangeless base B501:4"Flangeless mounting base SWIFT WIRELESS DEVICES B200S(-IV,-WH):Intelligent sounder base SWIF7is only compatible with System B200S:Intelligent sounder base Sensor(SK)devices.It is not compatible with Hochiki(SD)devices. Page 3 of 4—351608:8 9/26/2018 6808 Technical Specifications PHYSICAL NOTIFICATION APPLIANCE CIRCUITS(NACs) Flexput Honeywell", Overall Dimensions:16.36"W x 26.37"H x 3.91'D Four programmable circuits which can be JumpStart'",Silent Knight Shi Weight:32 lbs. programmed individually as: SWIFT'",and System ppin 9 9 Sensor"are registered Color:Red NACs:3A®27.4VDC per circuit,power-limited trademarks of Honeywell (with a maximum current of 6A) International Inc. ENVIRONMENTAL Auxiliary Power Circuits:3A@ 27.4VDC per circuit. o_ 120°F o power-limited Hochiki''is a registered Operating Temperature:32°F to 120 F (0 C to trademark of Hochiki 49°C) Corporation.Microsoft' Humidity:0 to 93°/o relative humidity(non- Supports Class B(Style 4)and Class A(Style 6 or 7) and Windows`-are condensing) configuration for the SLC registered trademarks of Microsoft Corporation. ELECTRICAL WIRING:See the product manual for wiring details This document is not 6808 Primary AC:120 VAC @ 6OHz,3.3A Total intended to be used for Accessory Load:6A @ 27.4VDC power-limited installation purposes.We StandbyCurrent:190mA try to keep our product information up-to Alarm Current:25OmA date and accurate.We Battery Charging Capacity:7 to 35AH cannot cover all specific Battery Size:7AH to 184H max.allowed in control applications or anticipate panel cabinet.Larger capacity batteries can be all requirements.All specifications are subject housed in RBB accessory cabinet. to change without notice. For Technical Support,call 800-446-6444. _ -- AIM Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 351608 I B 109/18 E.,SILENT 800-328-0103 ©2018 Honeywell International Inc. �r� 1C' --"lillIlli91 Honeywell®SILENT' KNIGHT I Fire Alarm Communicators CELL-CAB-SK and CELL-MOD Cellular Fire Alarm Communicators The CELL-CAB-SK and CELL-MOD are cellular communicator options for the Honeywell Silent Knight 6000 Series addressable fire alarm control panels(FACPs). These GSM communicators provide cellular communication as an alternate method of central station reporting.Combined with the FACP's onboard communicator,they tkx»wwen provide dual path cellular and IP reporting capability,while eliminating the need and ��< •., , cost of separate dialer capture modules and special programming.Battery backup from the control panel maximizes overall system efficiency. 111"11111 I Small size,easy to install,with a programmable supervision time of 1-60 minutes, CELL-MOD these communicators can be positioned remotely from the fire alarm control panel via 4-wire serial bus for optimum reception.The CELL-CAB-SK and CELL-MOD are UL 864 and NFPA 72 fire code compliant for sole,primary,and backup communications.They work with AlarmNet'to provide a UL-listed connection to the central station. The CELL-CAB-SK includes a GSM communicator within a metal cabinet enclosure with lock and key and includes an external antenna.The CELL-MOD houses the GSM communicator in a plastic enclosure and has an option for an external antenna. CELL-CAB-SK FEATURES ES EN E SITS • Communicate directly • Battery backup • 864 and NFPA 72 • Remote mounting up • Programmable with Silent Knight6000 provided by the panel code compliant for to 6,000 ft(1,828.8 m) supervision time from 1-60 minutes (QOS)diagnostics via • Provide full data Series fire alarm to increase system sole,primary,and control panels efficiencyanddecrease backup • Quality of Service cost communications • Easy installation-no AlarmNet convey vital reporting using need for special * Provide dual-path • Easily managed communicator Contact ID format programming or cellular and IP accounts through information such as separate dialer module reporting capability on-line management when messages are tools received,signal strength,and message path used CELL-CAB-SK and CELL-MOD Technical Specifications PHYSICAL HSPA+(4G)and HSPA(HSDPA&HSUPA)(3G) AlarmNet",Honeywell',and COMPATIBILITY Silent Knight"are registered CELL-MOD:1.809"W x 5.982"H x 1.5"D trademarks of Honeywell (19.83cm x 15.19cm x 3.81cm) The CELL-CAB-SK and CELL-MOD are compatible with International,Inc. CELL-CAB-SK:10.38"W x 10.165"H x 3.176"D the following Honeywell Silent Knight FACPs: This document is not intended (26.37cm x 25.82 cm x 8.07cm) 6820: addressable FACP with up to 1,110 points to be used for installation SHIPPING WEIGHT 6820EVS: addressable fire alarm control panel with up purposes.We try to keep our to 1,110 points and an emergency mass notification product information up-to- CELL-MOD:1.3 lbs(589.7 g) date and accurate.We cannot system CELL-CAB-SK:5.2 lbs(2.36 Kg) cover all cations 6808:addressable FACP with up to 198 points or anticipate all requirements.fic l ENVIRONMENTAL 6700:addressable FACP with up to 100 points All specifications are subject to Operating Temperature:32°F-120°F(0°C-49°C) ORDERING INFORMATION change without notice. Humidity:10-93%relative humidity(non-condensing) CELL-CAB-SK:Cellular module housed in a red,metal ELECTRICAL cabinet with lock and key.Includes external antenna Standby Current:55mA CELL-MOD:Cellular module housed in a red,plastic Alarm Current:100mA enclosure.(External antenna sold separately) CELL-ANTENNA:3dB gain external/remote antenna RADIO TRANSCEIVER APPROVALS 3G Cellular Radio UMTS WCDMA FDD 850/1900MHz UL Listed FCC part 15,22,24,and 68 compliant CSFM Approved FCC ID:CFS8DLPHS8-US COMMUNICATION PROTOCOLS Honeywell Silent Knight 1N thford,ClintonvilleTRoad Honeywell Northford,CT 06472-1610 203.484.7161 351627 I c 111/18 rs T' SILEN www.silentknight.com 02018 Honeywell International Inc KNIGHT Honeywell I Accressable Devices ®SILENT' KNIGHT OSI-RI-SK Intelligent Single-ended Reflective Imaging Beam Smoke Detector General The OSI-RI-SK intelligent addressable reflector-type linear optical beam smoke detector is uniquely suited for protecting large open areas with high ceilings,where spot-type smoke detectors are difficult to install and maintain.Ideal applications are warehouses,atriums,aircraft hangers,sporting arenas and concert halls.The beam x � operates primarily on the principle of light obscuration using infrared.The OSI-RI-SK .; detector is a combined transmitter/receiver and is compatible with Silent Knight • Addressable Fire Alarm Control Panels. •m. 4V,14 Fast and Easy Alignment Aligning the imager to the reflector is extremely intuitive,fast,and accurate.Both the infrared transmitter and the CMOS imager are contained in a movable"eyeball"—an adjustable lens assembly that can move+/-20°in the vertical direction and 50°in the The OSt-RI-SKsingle-ended beam smoke detector is horizontal direction.Four LED arrows indicate the direction to move the lens,guiding easy to install and adjust.Only the head unit needs the user to find the imager's perfect alignment with the reflector.Once the optimum to be wired,and the"eyeball"can be aimed without alignment is found,indicated by all green arrows,the lens is locked with a slide lever. adjusting the detector mounting. A paintable cover is then placed over the front to secure the lever in locked position. Resistant to Building Movement,Sunlight,and Foreign Object Intrusion The infrared transmitter and receiver imager generates a beam of light towards a high-efficiency reflector.The reflector returns the beam to the receiver where the received signal is analyzed.The change in the strength of the received signal when smoke enters the area between the unit and the reflector is used to determine the alarm condition.The receiver imager has a wide 12°field of view that automatically tracks the reflector in case of building movement or support structure movement.This allows the OSI-RI-SK to be highly resistant to movement,eliminating the number one cause of false alarms and/or faults with traditional beam detectors. FEATURES & BENEFITS • Combined transmitter/ • 50°horizontal and 20° • Resistant to building • Remote test station • Paintable housing/ receiver unit vertical beam movement;tolerates capable for electronic cover • Wide 12°field of view adjustment +/-1°movement simulated smoke test . Removableto in from ground level p g • Long range coverage of • Resistant to strong terminal blocks • Fast,easy,and intuitive 16-328 ft(5-100 m)is tight sources;does not • Status LED indicators beam alignment standard;no separate alarm when saturated visible from the front ' Built-in imager heater indicated by LED long-range kit re required by and bottom directional arrows q Optional reflector • Automatic sensitivity • Resistant to solid • Automatic drift heater kit available threshold level setting object intrusion compensation Optical filtering,high-speed image acquisition and intelligent Time-saving Automatic Sensitivity Setting software algorithms provide the system with higher levels of stability Unique in the market,the sensitivity of the detector is selected and set and with greater resistance to high level lighting variability.This automatically at the optimum sensitivity based on the size of the provides better resistance to sunlight in its field of view,helping to reflector measured in the field of view. prevent false alarms when saturated by sunlight,reflected sunlight or any other very bright light sources. Drift Compensation The detector incorporates automatic drift compensation,whereby the Advanced smoke imaging techniques allowthe detector to avoid false detector will adjust its detection thresholds in line with any long-term alarms from partial and sudden blockage from foreign object signal reduction of the beam caused by dust or other contamination intrusion. of the optical surfaces. Equipped with Built-in Imager Heater The imager ships standard with an internal heating option to prevent condensation on the optical surface.(External power supply required.) Page 2 of 3—SK-61052:B•1/16/2019 OSI-RI-SK Technical Specifications PHYSICAL/OPERATING SPECIFICATIONS OPERATIONAL SPECIFICATIONS Silent Knight'is a registered trademark of Honeywell Dimensions(Detector):Height 6"(152.4 mm);Width 10" Protection Range:16 ft to 328 ft(5 m to 100 m) International Inc. (254 mm);Depth 4.5"(114.3 mm) Adjustment Angle:20 degrees vertical,50 degrees 02019.AR rights reserved. Dimensions(Reflector):Height 9.06"(230 mm);Width horizontal Unauthorized use of this 7.87"(200 mm) Sensitivity Levels:Level 125%,Level 2 300/o,Level 3 document is strictly Weight(Installed):2.48 lbs(1.12 kg) 40%,Level 4 50% prohibited. Weight(Shipping):3.91 lbs(1.77 kg) Test/Reset Features:Local alarm test switch,local alarm This document is not intended Wire Gauge for Terminals:14 AWG(2.08 mm2) reset switch,Remote test and reset switch(Compatible to be used for installation with RTS151 and RTS151KEY test stations), purposes.We try to keep our ELECTRICAL SPECIFICATIONS: OSID R test filter. product information up-to- date and accurate.We cannot OSI-RI-SK Smoke Detector Spacing:On smooth ceilings,30-60 feet cover all specific applications Operating Voltage Range: between projected beams and not more than one-half or anticipate all requirements. Nominal:24 VDC that spacing between a projected beam and a sidewall. Allspecifications are subjectto Minimum:15 VDC Other spacing may be used depending on the ceiling change without notice. Maximum:32.0 VDC height,airflow characteristics,and response Maximum Standby Current: requirements.See NFPA 72(S524 in Canadian 13 mA C 32 VDC applications). 14 mA @ 24 VDC AGENCY LISTINGS 20mA@15VDC Maximum Alarm Current(LED on): UL:S911 22 mA @ 32 VDC FM:PR449231 15 mA @ 24 VDC CSFM:7260-0559:0515 22 mA @ 15 VDC PRODUCT LINE INFORMATION BEAMHKR OSI-RI-SK:Intelligent imaging beam smoke detector Voltage Range:15 to 32 V including reflector Maximum Current:450 mA Max at 32 V OSP 002:Laser alignment tool OSP-004:Test filter,10 pack Power Consumption: RTS151:Remote test station 7.7 WP 24V RTS151KEY: Test and reset station with key lock,flush 15 W@ 32V mount BEAMHKR:Heater kit for the reflector RTS151KEY 6500-MMK:Multi-mount accessory for ceiling or wall Voltage Range: 10.2 to 32 VDC mounting with additional mounting adjustment Current Range::9 mA Min to 11 mA Max ENVIRONMENTAL SPECIFICATIONS Operating Temperature:UL-Listed for use from 32°F to 100°F(0°C to 37.8°C). Application Temperature Range:-4°F to 131°F (-20°C to+55°C) Humidity Range:0 to 95%relative humidity,non- condensing Honeywell Silent Knight Clintonville Road N Honeywell Northford,CT 06472-1610 203.484.7161 sK-61o52 I B 101/19SILENT' www.silentknight.com ©2019 Honeywell International Inc. ®KNIGHT Honeywell sm • KNIGHT SK=DT Intelligent Air Duct Smoke Detector The SK-DUCT Intelligent air duct smoke detector is used with SK-PHOTOR (included)for detecting smoke and products of combustion present in air moving through an HVAC air handling system.When smoke is detected in a duct,the unit communicates the condition to the Honeywell Silent Knight W control panel.The panel,in turn,depending on programming and wiring, e3 turns off fans,blowers,and other devices.The duct housing allows for mounting of SK-RELAY addressable relay module. � top The Model SK-DUCT Air Duct Smoke Detector utilizes photoelectric technology for the detection of smoke.It provides early detection of smoke and products of combustion present in air moving through HVAC ducts in SK-DUCT Commercial and Industrial applications. The SK-DUCT is in a heavy duty gray steel back box with a clear cover.It features a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct.It installs quickly and easily. The unit senses smoke in the most challenging conditions,operating in airflow speeds of 100 to 4000 feet per minute,temperatures of-4°F to 158°F,and a humidity range of 0 to 95 percent(non-condensing). • Versatile mounting • Rugged steel back box • Patented sampling options.square or with clear plastic cover tube installs from rectangular Easy to clean front or back of the •configuration detector with no tools • Large terminal required = New Cover tamper connection screws signal • Available space within * Transparent cover for housing to • LED alarm indication convenient visual accommodate and communication inspection on sensor head mounting of relay module • Detects and limits the • UL listed spread of smoke SK-DUCT Technical Specifications Fora complete listing of all PHYSICAL IMPORTANT NOTES: compliance approvals and _ (Rectangular):14.38"(37 cm)L X 5"(12.7 cm)W X •The use of either RTS151 or RTS151KEY certifications,please visit www.silentkn ig ht.com. 2.5"(6.6 cm)D requires the installation of an accessory coil, (Square):7.75'(19.7cm)L x 9"(22.9cm)W x 2.5"D DCOIL,sold separately.Please refer to the Microsoft,Windows,and (6.35cm) SK-DUCT installation instructions for more the Windows Logo are information registered trademarks Weight:1.6lb(0.73kg) or trademarks of •The RTS151/RTS151KEY test coil circuit Microsoft Corporation. ELECTRICAL(using SK-Photo or SK-PhotoR) requires an external 24VDC power supply which Operating Voltage:15-32 VDC must be ULlisted. Silent Knight System Sensor"and Honeywell' Standby Current:3001.1A:a 24 VDC max. ACCESSORY CURRENT LOADS AT 24VDC are registered Alarm Current:6.5 mA @ 24 VDC max(with LED Device Standby Alarm trademarks of Honeywell on) International,Inc. RA100Z 0m 12mA Max. This document is not ENVIRONMENTAL RTS151 OmA l2rnA Max intended to be used for Operating Temperature:-4°F—158°F(-20°C RTS151KEY 12mA installation purposes.We 70°C) 12mAMax try to keep our product Humidity:0%—95%(non-condensing) information up-to date and accurate.We COMPATIBILITY cannot cover all specific AIR VELOCITY The SK-DUCT is compatible with the following applications or anticipate 100 to 4000 ft/min: (0.5-20.3 m/sec.) Honeywell Silent Knight fire alarm control panels: all requirements.All 6820:Addressable fire alarm control panel specifications are subject ORDERING INFORMATION to change without notice. 6820EVS:Addressable fire alarm control panel SK-DUCT: Intelligent non-relay duct smoke with an emergency mass notification system. For Technical Support, detector 6808:Addressable fire alarm control panel catt800 446 6444. SK PHOTO: Addressable Photo Detector 6700:Addressable fire alarm control panel SK-PHOTOR: Addressable Photo Detector with 5700:Addressable fire alarm control panel remote test capability(included with SK-Duct) SK-RELAY: Addressable Relay Module,must be 5808:Addressable fire alarm control panel added if relay function is required,(fits in housing) 5820XL:Addressable fire alarm control panel 5820XL-EVS:Addressable fire alarm control panel ACCESSORIES with an emergency mass notification system. DST1: Metal Sampling Tube Duct Width up to 1' DST1.5: Metal Sampling Tube Duct Widths 1'-2' DST3:Metal Sampling Tube Duct Widths 2'-4' DST5: Metal Sampling Tube Duct Widths 4'-8' DST10: Metal Sampling Tube Duct Widths 8'-12' DH4000E-1: Weatherproof Enclosure ETX: Metal Exhaust Tube Duct width 1' RA100Z: Remote LED Annunciator DCOIL: Duct accessory coil,required if using with SK-PHOTO and not SK-PHOTOR(included)with SK-DUCT RTS151: Magnetic Remote Test station RTS151KEY: Key-Activated Remote Test station M02-04-00 Test Magnet P48-21-00 Replacement End Cap for Metal Sampling Tube APA151:Remote annunciator with piezo alarm .� For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 Doc 350122 Rei F!ung 800-328-0103 2017 Honeywell International Inc. M. SILENT KNIGHT \Honeywell ri SILENT' 1641 KNIGHT SK-HEAT-W Series Intelligent Thermal (Heat) Detector Honeywell Silent Knight SK-HEAT-W Series intelligent thermal detectors are designed for both performance and aesthetics.A new modern,sleek, contemporary design and advanced thermal technologies make the SK-HEAT-W Series ideal for both system operation and building design. The point ID address,set using rotary decimal switches,provide specific detector locations.The series includes a 135'F/57°C fixed temperature, rate-of-rise and a 190°F/88°C fixed high-temperature detectors.These ! . ,., thermal detectors provide effective,intelligent property protection in a variety of applications. SK-HEAT-W 1- L- AIL.i !-;, Lb ,L,: Ll_. ' i__. i iib • Sleek and stylish • High temperature • 360°-field viewing ,, i;;,,ii ,,--:. -,orial test • SE,t,_'fl against hack contemporary design model(SK-HEAT- angle of the visual switch activated by pressure W-HT)factory preset alarm indicators(two external magnet • Advanced thermal • Plugs into separate to 190°F(88°C) hi-color LEDs).LEDs technology for fast • Walk test with address base for case of blink green in Normal response • Addressable by device display(an address of installation and condition and turn on 121 will blink the maintenance • Fixed temperature • Two-wire SLC steady red in Alarm. detector LED 12- model(5K-HEAT-W) connection • SEMS screws for • Integral (pause)-1) factory preset to wiring of the separate • Visible LEDs"blink" communications and 135°F(57°C) • Low standby current base every time the unit is • built-in device-type • Rate-of-rise model addressed identification • Designed for • Optional remote. (SK-HEAT-W-ROR). directsurface or single-gang LED • Built-in tamper- • Remote test feature 15°F(8.3°C)perelectrical box accessory resistant feature from the panel minute mounting APPLICATIONS INTELLIGENT BASES ACCESSORIES Use thermal detectors for protection of B300-6:White,standard flanged CK300:Color Kit(includes cover and property.For further information,refer low-profile mounting base. trim ring),white,10-Pack. to manual 156-6541,Applications B300-6-BP:Bulk pack of B300-6, CK300-IV: Color Kit(includes cover - Manual for System Smoke Detectors, package contains 10. and trim ring),ivory,10-Pack. which provides detailed information on B300-6-IV:Ivory,standard flanged CK300-BL:Color Kit(includes cover _ detector spacing,placement,zoning, low-profile mounting base. and trim ring),black,10-Pack. wiring,and special applications B300A-6-IV:Ivory,standard flanged M02-04-01:Detector test magnet. low-profile mounting base.UL listed. M02-09-00:Telescoping test magnet. INSTALLATION B501-WHITE:White,standard RA100Z:Remote LED annunciator The SK-HEAT-W Series plug-in European flangeless mounting base.UL SMB600:Surface Mounting Kit intelligent thermal detectors use a listed. (flanged). separate base to simplify installation, B501-BL:Black,standard European TR300:Replacement trim ring for service,and maintenance.Installation nstructions are shipped with each flangeless mounting base.UL listed. B300-6,white. idetector 8501-IV:Ivory,standard European TR300-IV:Replacement trimring for flangeless mounting base.UL listed. B300-6-IV,ivory.. Mount base(all base types)on an B200S-WH:White,Intelligent, electrical backbox which is at least 1.5" programmable sounder base. (3.81 cm)deep. B200S-IV:Ivory,Intelligent, programmable sounder base. NOTE: B200SR-WH:White,Intelligent sounder •Because of the inherent supervision base for retrofit applications. provided by the SLC loop,end-of-line B200SR-IV:Ivory,Intelligent sounder resistors are not required.Wiring base for retrofit applications. "T-taps"or branches are permitted for Style 4(Class"B")wiring. B200S-LF-WH:White,Low Frequency Intelligent,programmable sounder •When using relay or sounder bases, base. consult the installation sheet for device B200S-LF-IV:Ivory,Low Frequency limitations between isolator modules Intelligent,programmable sounder and isolator bases. base. NOTE:Detectors must be mounted to one B200SR-LF-WH:White,Low of the Intelligent Bases listed below. Frequency Intelligent sounder base for ORDERING INFORMATION retrofit applications. SK-HEAT-W:Thermal heat detector, B200SR-LF-IV:Ivory,Low Frequency 135°F fixed,white. Intelligent sounder base for retrofit SK-HEAT-ROR-W:Thermal heat applications. detector,135°F rate of rise,white. B224RB-WH:White,plug-in System SK-HEAT-HT-W:Thermal heat detector, Sensor relay base. 190°F high temp,white. B224RB-IV:Ivory,plug-in System Sensor relay base. B224B1-WH:White,plug-in System Sensor isolator detector base. B224BI-IV:Ivory,plug-in System Sensor isolator detector base. SK-HEAT-W Series Detector Technical Specifications PHYSICAL COMPATIBILITY For a complete listing of all compliance approvals and Height:2.0"(51mm)installed in 8300-6 base The SK-HEAT-W series detectors are certifications,please visit - Diameter:6.2"(156mm)installed in B300-6 compatible with the following Honeywell Silent `^ww•silentknight.com. base 4.1"(104 mm)installed in B501 base Knight fire alarm control panels: Microsoft,Windows,and the Windows Logo are Weight:3.4 oz(95 g) 6820:Addressable fire alarm control panel registered trademarks or f 6820EVS:Addressable fire alarm control panel MicrosofttrademarksCr o ENVIRONMENTAL Miosoft Corporation. with an emergency voice system. Operating Temperature range: Silent Knight=,System 6808:Addressable fire alarm control panel Sensor'and Honeywellr9 Heat-Fixed temperature:-4°F to 100°F(-20°C are registered to 38°C) 6700:Addressable fire alarm control panel trademarks of Honeywell International,Inc. Heat-Rate of Rise(ROR):-4°F to 100°F(-20°C 5700:Addressable fire alarm control panel 0 5808:Addressable fire alarm control panel This document is not to 38°C) intended to he used for Heat-High Temperature:-4°F to 150°F( 20°C 5820XL:Addressable fire alarm control panel installation purposes.We g ptry to keep our product to 66°C) 5820XL-EVS:Addressable fire alarm control information up-to date and accurate.We Humidity:10%to 93%non-condensing panel with an emergency voice system cannot cover all specific applications or anticipate Thermal Ratings:Fixed Temperature Set point: AGENCY LISTINGS AND APPROVALS all requirements.All 135°F(57°C) For exact certification listings for each model, specifications are subject please reference the respective agency Web site. to change without notice. Rate-of-Rise Detection:15°F/min.(8.3°C/min UL listed:S2101 For Technical Support, High Temperature Heat:190°F(88°C)Electrical FM Approved call800-446-6444. Ratings CSFM:7270-0559:0511 ELECTRICAL RATINGS Voltage Range:15 to 32VDC peak Standby current(max.avg.):200u4 @ 24 VDC (one communication every 5 seconds with LED enabled). LED current(max.):4.5mA r®24 VDC("ON"). For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com H K Silent dight Honeywell 12 Clintonville Road Northford,CT 06472 Doc 351637 I Rev 4104/18 SILENT' 800-328-0103 ©2018 Honeywell International Inc. KNIGHT Honeywell SILENT 111.4 KNIGHT SK-PHOTO-W Series Intelligent Plug-In Photoelectric Smoke Detector Honeywell Silent Knight SK-PHOTO-W Series plug-in smoke detectors are designed for both performance and aesthetics.A new modern,sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software.Sensitivity is continuously monitored and reported to the panel.Point ID capability allows each detector's address to be set +` with rotary,decimal address switches,providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F(57°C)fixed temperature thermal sensing on the SK-PHOTO-T-W.The SK-PHOTO-R-W is a remote test SK-PHOTO-W capable detector for use with DNR Series duct detector housings. FEATURES E3 : i J ' I.. • New modern profile for • Dual LED design • Expanded color • .p.�� �s�.�t p_ improved aesthetics provides 360°viewing options isolator,and sounder • Stable communication angle • SEMS screws for bases technique with noise • Remote test feature wiring of the separate • Plugs into separate immunity from the panel base base for ease of • Low standby current • Built-in functional test installation and • Two-wire SLC switch activated by maintenance connection external magnet - • Optional remote, * Built- ntarnper- single-gang LED resistant feature accessory • Sealed against back pressure DETECTOR SPACING AND INTELLIGENT BASES ACCESSORIES APPLICATIONS B300-6:White,standard flanged CK300:Color Kit(includes cover and Honeywell recommends spacing low-profile mounting base. trim ring),white,10-Pack. detectors in compliance with NFPA 72. B300-6-BP:Bulk pack of B300-6, CK300-IV: Color Kit(includes cover In low airflow applications with smooth package contains 10. and trim ring),ivory,10-Pack. ceiling,space detectors 30 feet(9m). B300-6-IV:Ivory,standard flanged CK300-BL:Color Kit(includes cover For specific information regarding tow-profile mounting base. and trim ring),black,10-Pack. detector spacing,placement,and B501-WHITE:White,standard M02-04-01:Detector test magnet. special applications refer to NFPA 72. European flan Bless mountingbase.UL p 9 M02-09-00:Telescoping test magnet. System Smoke Detector Application listed. Guide,document A05-1003,is available RA100Z:Remote LED annunciator B501-BL:Black,standard European SM Surface MountingKit at systemsensor.com flangetess mounting base.UL listed. (flanged). INSTALLATION B501-IV:Ivory,standard European TR300:Replacement trim ring for flangeless mounting base.UL listed. B300-6,white. The SK-PHOTO-W Series plug-in detectors use a separate base to B200S-WH:White,Intelligent, TR300-IV:Replacement trimring for simplify installation,service,and programmable sounder base. B300-6-IV,ivory. maintenance.Installation instructions B200S-IV:Ivory,Intelligent, are shipped with each detector. programmable sounder base. B200SR-WH:White,Intelligent sounder Mount base(all base types)on an base for retrofit applications. electrical backbox which is at least 1.5" B200SR-IV:Ivory,Intelligent sounder (3.81 cm)deep. base for retrofit applications. NOTE: B200S-LF-WH:White,Low Frequency Intelligent,programmable sounder •Because of the inherent supervision • base. provided by the SLC loop,end-of-line resistors are not required.Wiring B200S-LF-IV:Ivory,Low Frequency "T-taps"or branches are permitted for Intelligent,programmable sounder Style 4(Class"B")wiring. base. B200SR-LF-WH:White,Low •When using relay or sounder bases, Frequency Intelligent sounder base for consult the installation sheet for device retrofit applications. limitations between isolator modules B200SR-LF-IV:Ivory,Low Frequency and isolator bases. Intelligent sounder base for retrofit applications. ORDERING INFORMATION B224RB-WH:White,plug-in System SK-PHOTO-W:Photoelectric smoke Sensor relay base. detector,white. B224RB-IV:Ivory,plug-in System SK-PHOTO-R-W:Photoelectric smoke Sensor relay base. detector.remote test capable,for use B224B1 WH:White,plug-in System with DNR(W)duct smoke detectors, Sensor isolator detector base. white. 8224B1-IV:Ivory,plug-in System SK-PHOTO-T-W:Photoelectric smoke Sensor isolator detector base. detector with thermal sensing,white. SK-PHOTO-W Series Detector Technical Specifications PHYSICAL COMPATIBILITY For a complete listing of all compliance approvals and Height:2.0"(51mm)installed in B300-6 base The SK-PHOTO-W series detectors are certifications.please visit Diameter:6.2"(156mm)installed in B300-6 compatible with the following Honeywell Silent www.sitentknight.com. base 4.1"(104 mm)installed in B501 base Knight fire alarm control panels: Microsoft,Windows,and the Windows Logo are Weight:3.4 oz(95 g) 6820:Addressable fire alarm control panel registered trademarks or 6820EVS:Addressable fire alarm control panel Microsofttrademarks of ENVIRONMENTAL Miosoft Corporation. with an emergency voice system. Operating Temperature range: Silent Knight',System 6808:Addressable fire alarm control panel Sensor'and Honeywell' Photo:32°F to 122°F(0°C to 50°C) are registered 6700:Addressable fire alarm control panel trademarks of Honeywell Photo with Thermal:32°F to 100°F(0°C to International,Inc. 38°C) 5700:Addressable fire alarm control panel 5808:Addressable fire alarm control panel This document is not UL listed Velocity range:Photo/Photo with intended to be used for 5820XL:Addressable fire alarm control panel installation purposes.We Thermal:0 to 4,000 fpm(0 to 20 m/sec) try to keep our product (suitable for installation in ducts) 5820XL-EVS:Addressable fire alarm control information up-to date and accurate.We Humidity:10%to 930/0 non-condensing panel with an emergency voice system cannot cover all specific applications or anticipate Thermal Ratings:Fixed Temperature Set point: AGENCY LISTINGS AND APPROVALS all requirements.All 135°F(57°C) For exact certification listings for each model, specifications are subject please reference the respective agency Web site. to change without notice. ELECTRICAL RATINGS UL listed:S6173 For Technical Support, Voltage Range:15 to 32VDC peak FM approved call 800-446-6444. CSFM:7272-0559:0523 Operating Current @ 24VDC:2000(one communication every 5 seconds with green LED blink on communication) Maximum Current:4.5m4®24VDC(one communication every 5 seconds with amber LED solid on). For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight / 12 Clintonville Road Honeywell Northford,CT 06472 Doc 351634 IRev A 104/18 D SILENT' 800-328-0103 0 2018 Honeywell International Inc. iili KNIGHT • Honeywell MISILENT"' KNIGHT SK-PULL-SA / SK-PULL-DA - Intelligent Pull Stations The SK-PULL-SA is a single action pull station requiring only one motion to activate the station.The SK-PULL-DA is a dual action pull station requiringFIRE two motions to active the station.The SK-PULL-SA and SK-PULL-DA are for use with Honeywell Silent Knight Series fire control panel(FACP). I PULL DOWN Extremely easy to operate,the SK-PULL-DA and SK-PULL-SA provide a fast and practical means of manually initiating a fire alarm signal.The FACP recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. Honeywell DMLer x.�x:xr )1 INSTALLATION The SK-PULL-SA and SK-PULL-DA can be surface mounted to an SB-I/0 SK-PULL-SA surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13°(5.40 cm)or double gang or 4"(10.61 cm)square electrical box.You can also use the optional(System Sensor"PN BG-TR) FIRE trim ring if the station is being semi-flush mounted. I PUSH IN I • PULL DOWN Honeywell - ,1 ©�iit1" 1 h\ICti7 { ii SK-PULL-DA �-- _- -_- c-._ • Installer can open • Key operated test and • Meets the Americans • Retiamb analog • I lardin iatuhes in station without reset lock using lock with Disabilities Act communications for down position and the causing an alarm plate actuator Accessibility trouble-free operation word Activated condition Guidelines(ADAAG) appears,clearly • Key matches • Braille text on station controls and operating indicating the station • Dual-color LED is compatible FACP handle visible through handle locks mechanisms has been pulled of station blinks green guidelines(Section • Rotary address • UL Listed,including • Meets ADA 4.1.3[13]) switches for fast to indicate normal requirement for 5 lbs installation UL 38,Standard of operation and remains maximum pull force to • Shell,door,and handle Manually Actuated steady red in an alarm active molded from durable Signaling System condition LEXAN • CSFM Listed • MEA Listed • SK-PULL-SA / SK-PULL-DA Technical Specifications For a complete listing of all compliance approvals and certifications,please visit PHYSICAL ORDERING INFORMATION www.silentknight.com. Dimensions:5.5"H x 4"W x 1.45"D(14 x 10.2 x SK-Pull-SA:Single Action Pull Station Microsoft,Windows,and 3.7cm) SK-Pull-DA:Dual Action Pull Station the Windows Logo are Housing Material:LEXAN polycarbonate resin registered trademarks Bi-Colored LED: ACCESSORIES or trademarks of Blinking Green:Normal BG-TR:Optional trim ring. Microsoft Corporation. Steady Red:Alarm SB-I/O:Surface backbox.indoor/outdoor. Silent Knight',System Switch:Single pole,single throw(SPST)normally *Unless otherwise noted,specifications apply to Sensor'and Honeywell open(N/0)switch which closes upon activation of SK-Pull-SA and SK-Pult-DA are registered the pull station trademarks of Honeywell COMPATIBILITY International,Inc. ELECTRICAL The SK-PULL-SA AND SK-PULL-DA are This document is not Operating Voltage:15-32VDC compatible with the following Honeywell Silent intended to he used for SLC Standby and Alarm Current:3501.tA Knight fire alarm control panels: installation purposes.We Wire Gauge:Upto 12AWG(3.1 mm2) 6820:Addressable fire alarm control panel try to keep our product 9 information up-to 6820EVS:Addressable fire alarm control panel date and accurate.We ENVIRONMENTAL with an emergency voice system. cannot cover all specific Operating Temperature:32°F-120°F(0°C- 6808:Addressable fire alarm control panel applications or anticipate 49°C) 6700:Addressable fire alarm control panel all requirements.All specifications are subject Humidity:10%-930/0 non-condensing 5700:Addressable fire alarm control panel to change without notice. 5808:Addressable fire alarm control panel For 5820XL:Addressable fire alarm control panel call 80 -446al 6444. call 800-446-6444. 5820XL-EVS:Addressable fire alarm control panel with an emergency voice system For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com H SilentRKnight Honeywell 12 Clintonville Road Northford,CT 06472 Doc 350135 Rev E 11/17SILENT' 800-328-0103 r;2017 Honeywell International Inc. ®KNIGHT • Honeywell (74 SILENT Ilia KNIGHT SK-RELAY " Intelligent Relay Mocule The SK-RELAY is an addressable relay module for use with Honeywell Silent Knight Series fire alarm control panels(FACPs).The SK-RELAY allows a Silent Knight FACP to switch discrete contacts by code command.The relay contains two isolated sets of Form C contacts,which operate as a DPDT switch.No supervision is provided for the notification appliance fax circuit. Honeywell c The SK-RELAY contacts can be used for virtually any normally open or normally closed application.Each SK-RELAY is programmed with a unique signaling line circuit(SLC)loop address.When an event occurs that controls the SK-RELAY,the relay is triggered by the FACP. (4; INSTALLATION The SK-RELAY mounts directly into a 4"square electrical box.The box must SK-RELAY have a minimum depth of 2-1/8".A surface mount electrical box(System Sensor`-'PN SMB500)is available from Silent Knight. FHA-FURLS BENE : 1 :) • Two sets of Form C • Panel controlled • Polling LED visibt . contacts status LED that through the cover • Rotary address flashes green in plate switches for fast normalstate and is . SEMS screws for easy installation solid red in alarm wiring • Contacts are rated for Relay programming is • UL Listed a variety of amps(see completely flexible- Specifications) can be mapped to zone conditions SK-RELAY Technical Specifications For a complete listing of all compliance approvals and certifications,please visit _ PHYSICAL ORDERING INFORMATION www.silentknight.com. 4.675"H x 4.275'W x 1.4"D SK-RELAY:Relay Module Microsoft,Windows,and Shipping Weight:6.3 oz(196 g) the Windows Logo are ACCESSORIES. registered trademarks ELECTRICAL SMB500:4"Square Surface Mount Electrical Box or trademarks of Operating Voltage:15-32 VDC CB500:Module Barrier Microsoft Corporation. End-of-Line Resistance:Not used ystem SLC Standby&Alarm Current:.255mA max Via? COMPATIBILITY Silentsr and neywe Sensor' and Honeywell" 24VDC(one communication every 5 sec with LED The SK-RELAY is compatible with the following are registered enabled) Honeywell Silent Knight fire alarm control panels: trademarks of Honeywell 6820:Addressable fire alarm control panel International,Inc. ENVIRONMENTAL 6820EVS:Addressable fire alarm control panel This document is not Operating Temperature:32°F-120°F(0°C-- with an emergency mass notification system. intended to he used for 49°C) installation purposes.We 6808:Addressable fire alarm control panel Humidity:10%-93%non-condensing try to keep our product 6700:Addressable fire alarm control panel information up-to RELAY CONTACT RATINGS 5700:Addressable fire alarm control panel date and accurate.We 3.OA is 30VDC resistive 5808:Addressable fire alarm control panel cannot cover all specific 5820XL:Addressable fire alarm control panel applications or anticipate 0.9A @ 110VDC resistive all requirements.All 0.9A @ 125VAC resistive 5820XL-EVS:Addressable fire alarm control panel specifications are subject with an emergency mass notification system. to change without notice. 0.5A @ 125VAC inductive(PF=.35) 0.7A C5 75VAC inductive(PF=.35) For Technical Support, call 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 Doc 350127IRev GI 11/17SILEN ' 800-328-0103 ©2017 Honeywell International Inc. ® TIINIGHT *Th, SYSTEM � SENSOR® tirI.tiiM t 1:1:1:1.1 )E F I I t � �� I I� ;f Indoor Selectable- ii Output Horns, Strobes, and Horn Strobes for �; 3 Wall Applications System Sensor L-Series audible visible notification , , *.t , ,,•,,,,,.',,. :' ': Ji., ,,,,poiir,v4 it ''''''',''' ''' products are rich with features guaranteed to cut �a . installation times and maximize profits with lower current draw and modern aesthetics. Features.. • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and - • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red plastic housings,standard and compact devices,and plain, FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela • Field-selectable candela settings on wall units: The L-Series line of wall-mount horns,strobes,and horn strobes 15,30,75,95, 110, 135,and 185 include a variety of features that increase their application versatility • Horn rated at 88+dBA at 16 volts while simplifying installation.All devices feature plug-in designs • Rotary switch for horn tone and two volume selections with minimal intrusion into the back box,making installations fast and foolproof while virtually eliminating costly and time-consuming • Mounting plate for all standard and all compact wall units ground faults. • Mounting plate shorting spring checks wiring continuity before device installation To further simplify installation and protect devices from construction • Electrically compatible with legacy SpectrAlert and SpectrAlert damage,the L-Series utilizes a universal mounting plate for all Advance devices models with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Strobes and Horn Strobes listed for wall mounting only Installers can also easily adapt devices to a suit a wide range • Horns listed for wall or ceiling use of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING 1.11P/ ® 4> LISTED APPROVED Iii _, I S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383,3057072 AVDS865-05•2/22/2018•Page 1 • L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series • products,when used with the Sync•Circuit°'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service,The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize Strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 1.91"D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"Lx4.7"Wx1.25"D(143mmLx119mmWx32mmD) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133 mm L x 88 mm W x 32 mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-05•2/22/2018•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-175 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 • 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Wall Horn Strobe,Candela Range(15-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 _-----.-__...-.--._-------.-----�___ 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 *Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must - be provided by the NAC.If the NAC voltage is held constant,the horn output remains constantly on. AVDS865-05•2/22/2018•Page 3 L-Series Dimensions ---t 1.91" l. 32 mmm 86 mm _125" __-_ 357' – 1.55' 3.46" 66 mm 32s" 32 mm (9.1 aM (3.9 an) v` 4� 'l/ll r.� N a,a,yaapi°aa,a ;a�40�,:,: ', 1 1 ''-i. n 5.27" .a,a,a;°,°,a, „°°a°4o°oUo°o 1 5.33" O C 133.9 mm /I' 527 ,0446:48? ,.� (13.7 cm) 1339mm °papapapapa, -_ III ®,a,e,a,a,a,a mii �j N �qa:• aaaaaa a� A0548-00 A0547-00 A0557-00 Compact Strobe,Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL,SBBGWL (11.94 cm) _ — (4 5 - 32 mm (12.24 cm) -� 119 mm � (4.85 cm) 1.85" 1,25 (4.69cm) iii/ (318 mm) �� �� J p �( u , �� Jam- , c 4 aa° MP 1 ' 5.73 5.67• •'"'"'"'.�� iii 5.6T' 14.66cm) ,..,' le,144 mm(14.4cm) ahaa°a4°a aaaaa I�� ,r ., aaaaaa r - i. i •a a!a!ah!a �, o� 1 r A0550-00 A0549-00 A0554-01 Strobe,Horn Strobe Horn Wall Surface Mount Back Box SBBRUSBBWL L-Series Ordering Information Model Description Model Description Wall Horn Strobes Horns* P2RL 2-Wire,Horn Strobe,Red HRL* Horn,Red P2WL 2-Wire,Horn Strobe,White HWL* Horn,White P2GRL/ 2-Wire,Compact Horn Strobe,Red HGRL* Compact Horn,Red P2GWL 2-Wire,Comp 2 fils act Horn Strobe,White HGWL* Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P P2RL SP 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBRL Wall Surface Mount Back Box,Red P4RL 4-Wire,Horn Strobe,Red SBBWL Wall Surface Mount Back Box,White P4WL 4-Wire,Horn Strobe,White SBBGRL Compact Wall Surface Mount Back Box,Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box,White SRL Strobe,Red Mit_ Strobe,White ' / SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover). All-SP models have"FUEGO"marking on cover. All-ALERT models have"ALERT"marking on cover. *Horn-only models are listed for wall or ceiling use. Th, SYSTEM SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2018 System Sensor. �$ SENSOR Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to change without notice Visit systemsensor.com for current product information,including the latest version of this data sheet. www.system sensor.com AVDS865-05.2/22/2018 6MSSTEN SMOKE ..1V SENSOR® ii t 1swv . x Duct Smoke ,b , Detector Accessories i3 1°34 V. �r Expand the versatility of the InnovairFlex'"line of duct d smoke detectors with System Sensor notification and , k, r erA3 test accessories. '7}g Available Accessories Duct smoke detector accessories add functionality to the duct APA151 Piezo Annunciator smoke detection system by allowing quick,convenient inspections at eye level and effective audible and visible notification options.All MHR Mini-Horn,Red System Sensor duct smoke detectors and accessories are UL listed. MHW Mini-Horn,White - The APA151 piezo annunciator,which replaces the APA451 with RA100Z/RA100ZA Remote Annunciator a new,improved look,provides an audible alarm signal,a red LED RTS151 Remote Test Station to indicate alarm status,and a green LED to indicate power status. RTS151 KEY Remote Test Station with Key It is intended for use with System Sensor 4-wire conventional duct smoke detector applications without a system control panel,to RTS2 Multi-Signaling Accessory comply with NFPA 90A. AOS Add-On Strobe The MHR and MHW SpectrAlertw Advance mini-horns feature RTS2-AOS Multi-Signaling Accessory temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single-gang back boxes for applications where a small device is desired. The RA100Z and RA100ZA remote annunciators are designed for both conventional and intelligent applications.Their red LED provides visual indication of an alarm condition. The RT5151 and , I5I 'remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location.For 4-wire detectors,the RTS151 KEY test station features a multi-colored LED that alternates between steady green and red.For 2-wire detectors,the LED illuminates red for alarm. The RTS2 and RTS2-AOS multi-signaling accessories are designed to work with InnovairFlex 4-wire conventional duct smoke detectors. These accessories include a key switch that can be used to select one of two connected sensors to be tested,reset,or both by a push button switch.They also enable sensitivity measurements using Agency Listings the SENS-RDR sensitivity reader(sold separately).The AOS(Add-On Strobe)is an optional accessory included with the RTS2-AOS model. .. 0 4> r...) LISTED APPROVED "'I Specifications,Duct Smoke Detector Accessories APA151 Piezo Annunciator RTS151 Remote Test Station ; Voltage Regulated 24VDC Power Requirements Alarm LEL) 2.8 to 32VDC,12 mA max. Operating Voltage 16 to 33 VDC Total Current:105 mA max. - Maximum Alarm Current 30 mA Test Switch 10 VA @ 32 VDC Temperature Range 0°C to 49°C(32°F to 120°F) Reset Switch 10 VA @ 32 VDC Relative Humidity 10 to 93%non-condensing Alarm Response Time 40 seconds max. Wire Gauge 12 to 18 AWG Temperature Range -10°C to 60°C(14°F to 140°F) Dimensions 4.6"H x 2.9"W x.45"D Relative Humidity 95%non-condensing MHR/MHW SpectrAlert°Advance Mini-Horns r I- ` Wire Gauge 14 to 18 AWG Voltage Regulated 12 DC or FWR(Full N/ave Rectified) Dimensions 4.8"H x 2.90"W x 1.4"10 or Regulated 24 VDC or FWR y,1 ,r r Remote Test Station with Key Operating Voltage 8 to 33 VDC Power Requirements Power LED(Green):14 to 35 VDC,12 mA max. (9 to 33 VDC with Sync•Circuit"Module) Alarm LED(Red):2.8 to 32 VDC,12 mA max. Sounder Current Draw 22 mA RMS max.at 8 to 17.5 Volts DC Total Current:105 mA max. 17 mA RMS max.at 8 to 17.5 Volts FWR Alarm Response Time 40 seconds max. 29 mA RMS max.at 16 to 33 Volts DC Temperature Range -10°C to 60°C(14°F to 140°F) 25 mA RMS max.at 16 to 33 Volts FWR Relative Humidity 95%non-condensing Temperature Range 0°C to 49°C(32°F to 120°F) Wire Gauge 14 to 18 AWG Humidity Range 10 to 93%non-condensing Dimensions 4.6"H x 2.75"W x 1.8"D Nominal Sounder Frequency 3 kHz �� RTS2 and RTS2-AOS Multi-signaling Accessory Wire Gauge 12 to 18 AWG Voltage 20 to 29VDC Dimensions 4.6"H x 2.9"W x 0.45"D Power Requirements Standby:3.0 mA max. RA100Z/RA100ZA Remote Annunciator 'rr;I ., Trouble:16.0 mA max. Voltage Range Conventional System:3.1 to 32 VDC Alarm without strobe:30 mA max. Intelligent System:18 to 32VDC Alarm with strobe:55 mA max. Maximum Alarm Current 12 mA Sounder 85 dBA at ten feet Dimensions 4.6"H x 2.8"W x 1.3"ID Temperature Range -10°C to 60°C(14°F to 140°F) - Relative Humidity 95%non-condensing Wire Gauge 14 to 22 AWG Dimensions 4.8"W x 5.3"H x 1.6"D For the very latest product specifications and listing information,please visit the System Sensor Web site at www.systemsensor.com. C _. a; ` °, it E 3r %o -° ; l s3 ." , ' p 8 z 1P i x, ,q A h ,.w S "it . 1 ';40404 `.1 TM'y tS 4z ' I. i9 t9,,, ,. RTS151 UL 54011 RTS151 KEY UL 52522 APA151 UL S4011 1ITS2-AOS UL 52522 -- - PlEttiestWilli j 4 RA100Z UL 52522 MHW UL S4011 MHR UL S4011 AOS *--Th_ 7,SYSTEM _ rra201,System Sensor ✓ r/ 3825 Ohio Avenue•St.Charles,IL 60174 a ts <s�atr ss��e�t�a m> nog ..ys� temse, ,mror �,_ .5E/V ' R' Phone:800-SENSOR2•Fax:630-377-6495 e rr du¢nfrrm 0055-04-04ndrd gmel;e r e'o i'sdats heft 2.3 001•2,0 t2309 SYSTEM $ SENSOR . Outdoor Selectable- 404 Output Horns, ,444 Strobes, and Horn Strobes for Wall Applications SPECTFIert SpectrAlert Advance outdoor audible visible products A d v o N c E are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from-40°F to 151°F. • Field-selectable candela settings: 15, 15/75,30,75,95, 110, 115, Like the entire SpectrAlert Advance line,outdoor horns,strobes, 135, 150, 177,and 185 and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation.First, 15/75 candela field-selectable settings,including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable installers to easily adapt devices to meet requirements. • Horn rated at 88+dBA at 16 volts • Rated from-40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before devices are installed,so installers can verify proper wiring without • Plug-in design with minimal intrusion into the back box mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater •'T corrosion. Knock-outs located on the back eliminate the need to drill SIGNALING ( CI) O) holes for screw-in mounting.Plastic and metal weatherproof back ISI boxes come with 34-inch top and bottom conduit entries and 34-inch LISTED MEA 7300-1653:187(outdoor strobes) approved 7125-1653:188(horn strobes, knock-outs at the back.A screw-in NPT plug with an 0-ring gasket 54011(Chimes,horn strobes,horns) APPROVED chose strobes) 63593(outdoor and vert strobes) 3023572 MEA452-05-E 7135-1653:189 moms,chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe,and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. - Also,SpectrAlert Advance products,when used with the Sync•Circuit° Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification • appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between-40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15,15/75,30,75,95, 110, 115, 135,150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications ° �, 1 " T` .� w� '' Operating Temperature -40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"Lx4.7"Wx1.3"D(142mmLx119mmWx33mmD) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7"L x 5.1"W x 2.0"D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. SII AVOSO12O1 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 N9n-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 77 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output(dBA) candela ratings must be reduced in accordance with 8-17.5 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic _ Strobe Output(cd) Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at—40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal _ 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. Avoso,zo, SpectrAlert Advance Diagrams 14-4.7" ► 2.5'=. - ..r MMI T� \ \ 1 // 1."."..s...... . ■ I 5.6" 111O': 0 /I `t r `�III V ■� Wall-Mount Horn Strobes ���^ 7Wall Plastic Weatherproof Back Box 4 I 1I 0 I UPf ND Wall-Mount Horn Strobe with Plastic Weatherproof Back Box - SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P2RK*t 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK•t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK`t 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor,120 V(includes plastic weatherproof back box) Wall Strobes SRK*t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK*t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK*t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK`t/ Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. SYSTEM ©2012 System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Visit systemsensor.com �� SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 " for current product,cforrrratonjccVdsig the latest veroorr of th data sheet. AVDS01201•3/12