Plans (81) rra Senju RC-RES:Open Web Truss/T)I Construction Insulation Recommendations See General Notes 8.2.5.7 for Architectural e AquaSAFETM ProPEX LF Brass Fire Io areas subject to uaPE freezing,care ompld beltaken n lation. attic oaces � to cover Uponor AquaPEX tubing completely with Insulation. Insulation Feature Requirements u, 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2016 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM Sprinkler Adapter Tee should follow the guidelines of the insulation manufacturer, See Uponor 1611. z BlockingMaybeFireSprinkler Adapter - f SECTION 3.3.11.3. -\ -- -- push-on Nut Document"Uponor AquaSAFE Attic Insulation Guidlines"for attic } k 4 P,' } Required.If installation guidelines(Provided in Contractors Documents package or online / /'1 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON 9 ( ,s ( 1 ' Blocking is Used, s -� `_ 1 t/q"Min. at www.Uponorpro.com). i / O P�1 THIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND ry:::'� t/ " Use The 2 Top ?;. UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. ' :" Screw Holes. • j t 1 Max." Planter Box Window,BayWindow or Similar Feature. ® - L : / Bottom of Mounting Extreme Temperature Installations J Bracket to Face of Truss If no additinal floor area is created No Additional Sprinkler is Required. r , 0 0 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE _ _ Aq other AFE Residential Fire Safety systems are often installed in attics or `r C:)40 <o P 1 2019 Fire Sprinkler Adapter areas exposed to temperature extremes of heat and/or cold. Follow 8'-0"or less RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE Mounting Bracket the recommended extreme weather installation instructions to isolate and / .. PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE m 3° SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE 4 (b s. protect system components from extreme temperatures. Because this r _s ' r l v+„u SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. ='' r "ii-jii i ',e d q f r 3-#10 x 11/2" �°J �J system also delivers domestic cold water directly to plumbing fixtures, 9'-0"or less ® • fie/ j" r f?) ,,,v-.. ^•y �•c Full Course I I \ Uponor highly recommends that you protect the tubing with adequate / 4' W u"n 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH 3 E. ...)" i tom.i V f^q { i f\I Thread Screws 'd �• insulation in warm weather areas to minimize heating of the cold water y, a NFPA 13D 2016 EDITION. '" -'i'- supply. o u\ o a In Bottom Holes - methods include, ut are not 5. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE NOT PERMITTED TO USE ANTI-FREEZE. rse r \ - .nstalla�tat�ional layers of battbnsuW piping.limited to: If additional floor area is created.Cannot exceed 18 ft,be more than 2'-0" o,,F 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR Lead-Freq Plat DAMAGED MUST BE REPLACED. - ConcealL"c Senju C .. Concealed Flat • Increased depth of blown-in insulation, deep,more than 9'-0"wide and be with in the coverage area of the < o Sprinkler Head Cover Plate • sprinkler.No Additional Sprinkler is Required. o 5 i';4.8. . m 7. WATER SHUT OFF VALVE IS NOT PERMITTED THAT ISOLATES THE SPRINKLER SYSTEM. Caution: If you will be installing spray foam insulation,make sure to %>� F,-.4.264n. protect all components during application.Consult with the spray foam m❑ pp°m s 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. Senju RC-RES:Traditional Wood Framing Construction d z manufacturer to ensure compatibility with all products before application. NFPA 13D Table 7.5.5.3 Distances From z h a w° z i 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING,THE Heat Sources 5 w o o 0<o C 5;f u,g WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND Consultation with local building officials is encouraged to ensure compliance F,5 „, m �,a-m p PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR ProPEX LF'Brass Fire with local building codes. OrdinaryIntermediate 3 R z i AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, Sprinkler Adapter Tee Fire Sprinkler Adapter ,9.-t.,, .°„,-,1.--,0:11W1- r- z FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM , , Push-on Nut Heat Source Temp. Temp. M z >o•;•, WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE ✓- 135°-170• 175•-225• °zzzmoanwsx`o THIS SIGN". Bending PEX Tubing Side of Fireplace 36" 12° S ^egE°i x m m� =z 1 1'4'Min. The minimum bend radius of Uponor PEX tubing in any direction is six times Front of Fireplace 60" 36" W w p m N>y<a <<❑ 10. ALL INTERIOR PIPING TO BE UPONOR" (6 ) ° O z o AquaPEX®"UNLESS NOTED. 1 'Max. the outside diameter x OD. Fire Sprinkler Adapter - Bottom rt Mounting Bend supports are available for 3/8",1/2",3/4"and 1"Uponor AquaPEX Wood Burning Stove 42" 12" I i<0'n i t:Z z f 1<G'u 11.UPONOR"AquaPEX"TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. Mounting Bracket sracket to-ace Nauss tubingto facilitate 90-degreerigid bends. Kitchen Range 18" 9" e,<, f 4 o z o o m a m o z \��/ 9 J,.�u U~uanfo �,`v�' Wall Oven 18" 9' U 1.15 5 0 55 12.MINIMUM SPACING BETWEEN SPRINKLERS IS 8'-D" REFER TO SPACING CHARTS FOR MAXIMUM SPACING 2-#10 x 1 1/2°- �O• V Recommended Tubing Length Between Fittings Hot Air Flues 18" 9' N o °v z z o m`<y u BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE Full Course o v^'-+< u- RESTRICTIVE SPACING LIMITATIONS. Thread Screws 12 u-l I - Fitting Size Minimum Tubing Length Uninsulated Heat Ducts 18" 9' m z o oo z h u,-c' ❑i"'w 1-� ti x3mr-mygo��E` In Top Holes 7 V_J/ LJ 3/8"ProPEX Fitting 2. Uninsulated Hot Water Pipes 12" 6" x g ❑z r <u S o 13.SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING Side of Hot Air Diffuser 24" 12° o L Z 5 g 3,7°4"o`le°5" MOUNTED OBSTRUCTIONS. < °d F" -, ❑ 1/2°Pr0PEX Fitting 2 1/2" Front of Hot Air Diffuser 36" 18" o LL S r I>> <S< 14. THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE 3/4"ProPEX Fitting 3 1/2" Hot Water Heater 6" 3° �a Z u'< 0 f m 5 o 5 Lead-Free Flat---Pi,.' J ❑uo�s C"m° F� SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. 1"ProPEX Fitting4 1 2" Furnace 6" 3' G>5 x > ^z o Concealer Senju Concealed Flat / - .,c o<v, <1'-❑ 15.THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN Sprinkler Head g 5 1/2" SOW-250W Light Fixture 6" 3" `.°o$>- m z it s m c Cover Plate 1 1/4"ProPEX Fitting CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT IS 250W-499W Li4ht Fixture 12° 6" w u I=0 3❑o 5 o z Y z >�'arn "���o g THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. h��a z as°ci oa.",q a w 16. NFPA 13D 8.2.5*OBSTRUCTIONS TO RESIDENTIAL SPRINKLERS Exposed Installation Requirements. \ '" " �: ` • 8.2.5.6* SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS Uponor AquaPEXTM tubing(white)and ProPEXTM EP Fittings and ProPEX'r' THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FT°PER SPRINKLER. Brass Fittings are approved for exposed installation where the following • 8.2.5.7 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY conditions are met.(UL 1821 Approved) WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: - /� / (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO Exposed Wood]dist Ceiling Assemblies. S ry �Y �/® I here by certify that this plan,spe ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. 1. Joists are of dimensional lumber,engineered wood,wood I-joist or n ,-.5 ° (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL 9 1 Pe m or report was prepared by me or ui web wood joists. direct supervision and that I am NI SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; ' ' [D 2. Joist are of depthsinfrom 6-16-inches 5 mm). Certifi I IV (a)THE FLOOR AREA SHALL NOT EXCEED 18 F'T'(1.7 Ma) 3. Joist are of spacing from 12-24 inches(305-610 mm)on center. (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 2 FT IN DEPTH AT THE DEEPEST POINT OF i Ic THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED 4. Joists can be exposed after installation. _ 5. Metal pipe hangers spaced at maximum 24 inches(610 mm)on center 1.55' 1.66" Brent ill-Tdli1/• ALONG THE FINISHED FLOOR. are used. (c)THE FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE j„ Date: 8/15/1" Reg.No.11: PLANE OF THE PRIMARY WALL. 6. Listed residential automatic sprinklers of maximum activation 2 -g" Hanger 1" Hanger (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER temperature rating of 155°F(68°C). n SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. 4, (Anchor A SupportSpacing: 'n (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE Metal Tubing Support. (Anchor AquaPEX TubingSecurelyEnough to Su L.2 ARCHITECTURAL FEATURE. 1. Metal tubing supports designed for plastic tubing shall be used. Enough to Allow the Tubing to Expand anduContract) the Tubing,Yet Relaxed 2. Do not use supports that will damage the tubing.Inspect metal 17. NFPA 13D 8.3 LOCATION OF SPRINKLERS. pports for sharp edges. 1. Along Horizontal Runs,Install Supports Every 32",if Horizontal Runs are a • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 CITY OF TIGARD 3. Do not rigidly anchor Uponor AquaPEX• tubing with supports.Allow Continuously Supported,Place Tubing Supports at Six-Foot Intervals. THROUGH 8.3.8. • enough tubing for freedom of movement to expand and contract. 2. Along Vertical Runs,Install Supports Every Four to Five Feet,at Each o • 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FT.(5.1 Ma)AND LESS Approved l>4 Floor and ata Mid-story Guide. is • 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT I z a MEET ALL OF THE FOLLOWING CONDITIONS: Conditionally Approved t l In-line Flow Test ti z (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FTS(2.2 Ma), z x (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE C The In-lineeproper Flow system Testcanp bea i constructed(sees tF. It performs F001- )flow test to m SO iT See Letter to: Follow [ , Standard Riser Assembly ensure operation and flow Figure Fooi B). E z MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. j p ry m • 8.3.40 SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,ANDIn a safety system a single control valve controls both domestic and LU 8 in SIMILAR STRUCTURES Attached [ , fire safety needs. a',:,..1 °a'" /y, Uponor AquaPEX O re m ot. • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE Permit Number: •rSTe�cti g'-00332- Tubing q /�i� Q m mm EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO ANDo .1 / CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, Address: r S f7/{:/ b !•/c s id d.� ,4�• / f c m 1ll CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING ll 7 �7 Vr V 7 /a•ws�•". F%//////// C�// z PURPOSES. By: w / LL x .4G+K37 alte: I % LLJ o . r m • 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR L<:...f., �f 7�,'] J / Ii �k z -iii r 8.3.5.1.2. r E < z "� • 8.3.5.1.1 WHERE THE FUEL-FIRED EQUIPMENT IS ABOVE ALL OF THE OCCUPIED AREAS OF THE DWELLING ---_--'-r- ---__------ ------- �/ g03.15 z z ~O 9 oLL • UNIT,NO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. m • 8.3,5.1.2 WHERE FUEL-FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE i O O o 5 DWELLING UNIT,AT LEAST ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE �A( Male Threaded Coupling • ProPEX Fire �( u O u<3'' 5 INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIRED V .� Sprinkler Adapter EQUIPMENT FROM THE OCCUPIED SPACE. Y • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN COVERED,UNHEATED PROJECTIONS OF THE BUILDING AT 1"Ball Valve HI F. To Hot Water Heater Male Threaded Coupling u ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. Ce • 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING , Female Threaded `e ce CONDITIONS: F "� Tae with Water S H (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS INA COMPARTMENT DOES NOT EXCEED 2 tNiL _ Pressure Gauge O r o i 100 FT.(2.83 M.). y Sprinkler Orifice (Optional) o (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS w : u .a.w sc m AT THE LOWER CEILING ELEVATION. E Y ( Uponor Warning Signs m=i=