Plans (85) ... s LSh� /t ,,,,,,,,..._ : vs. , I Table 80-1 Maximum Unit And Corner Weights(Lbs)And Center Of Gravity Dimensions(In.) Unit Maximum Weights(Lbs) Corner Weights(Lbs)1 Center of Gravity(In.) Tons Model No. Shipping Net A B C D Length Width 3 YCD036C/YCD037C 782/811 621/651 209/217 158/159 116/124 138/151 37/36 19/20 4 YC*048C,/YC*049C 811/845 639/672 216/221 159/168 123/131 142/153 37/37 19/20 5 YC*060C./YC*061C 831/901 659/713 219/230 163/176 126/137 152/170 36/38 20/21 61/4 YC*075C/YC*074C 938/956 7501767 238/240 192/199 144/151 176/177 39/40 21/21 YC#090ClYC*086C 9821965 793/777 262/246 203/199 151/151 177/180 39/39 21/21 Single Compressor 7'fz YC*090D/YC#091D 1044/1057 855/869 297/298 208/214 151/156 199/200 37/37 20/20 Dual Compressor 81/2 YC*1028/YC#1038 1425/1488 1150/1213 382/400 309/333 201/221 248/260 42/43 29/25 10 YC*120B/YC*121B 1465/1506 1190/1231 398/400 321/333 208/221 258/277 42/42 25/26 121 YC*1508/YC*1518 1755/1843 1415/1503 496/512 359/372 248/258 342/360 45/46 29(29 15 YC*180B/YC*181B 1795/2459 1415/1994 512/634 372/520 257/371 354/468 45/55 29/36 171/2 YC*2108/YC*211 B 2330/2441 1880/2021 614/648 471/531 330/373 430/470 53/55 35/35 20 YC*240B/YC*2418 2415/2521 1995/2101 656/700 503/535 352/376 459/491 53153 35/35 • 25 YC*3008 2525 2105 701 537 376 491 53 35 NOTE: 1. Caner weights are given for information only.81/2-25 ton units must be supported cort.nuously by a curd or equivalent frame support. CENTER OF GRAVITY LENGTH A9 CENTER 1 I GRAVITY O O VALIDITY OF PERMIT WIDTH • THE ISSUANCE OF A PERMIT BASED ON CONSTRUCTION DOCUMENTS AND OTHER DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM REQUIRING THE CORRECTION OF ERRORS. OSSC 105.4 D c CENTER OF GRAVITY 7 THE ACTIVATION OF A DUCT SMOKE DETECTOR SHALL ACTIVATE A VISIBLE AND ;: . ,.,_�_., AUDIBLE SUPERVISORY CITY OF TIGAI SIGNAL AT A CONSTANTLY REVIE FOR CODE COMPLIANCE ATTENDED LOCATION Approved: OMSC 606.4.1 I OTC: j ] ,„ Permit#: hner-A&�191-�'Y.'� CSS 9 Address: ) 4a 0 0 cS',,v pr.C-► -c: c t y Suite#: `Indicates both downflow and horizontal units. By: _4_4. Date: -1 f- II)` JJI ' -1S)1 80 . v eilA) aim+ SUBMITTAL DATA Order#: Date: 07/16/2019 Project: Rite Aid 5355 Tigard OR REV 2 Project#: Submitter: Joe Ray UPG National Accounts 5005 York Drive., Norman, Oklahoma 73069 405-419-6613 Information is subject to change without notice.Check local codes. Printed 07/16/2019 Date 07/16/2019 Project Name Rite Aid 5355 Tigard OR REV 2 Project Number Client/Purchaser Submittal Summary Page Qty Tag# Model# Description 1 ZE060K10B4A1AAA1A1 5 Ton, York Small Sunline Single Packaged R-410A Air Conditioner, Single Stage Cooling, 11.8 EER/ 14.0 SEER, 100 MBH Input, Single Stage Low Nox Gas Aluminum Steel,460-3-60 • 1.5 HP Standard Static Belt Drive Blower • 1"Throwaway Filters • Smart Equipment Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors. • Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin Evaporator Coil • Galvanized Steel Drain Pan • Standard Access Doors 1 S1-SE-COM1001-0 Field Installed Communication Card for Simplicity SE control. Can be field configurable for BACnet, N2 or ModBUS MSTP 1 1 RD0410 Barometric Relief Damper with Hood Kit(Downflow Unit or Duct Mounted) 1 2EE04709024 Dry Bulb Low Leak Economizer(Hood Kit included for field assembly and installation) 1 1-3000-5005 Curb Adapter Old Model:YCD060A(OLD UNIT ONLY) New Model: ZE060 Top Brace; Insulated Condenser Panel (where required); Fully Insulated (1" Duct Liner R Value 3.85) Equipment start-up and commissioning by a factory trained technician is recommended. Contact your supplying distributor or sales representative for additional information &guidance. A\WARNING:Cancer and Reproductive Harm-www.P65Wamings.ca.gov Information is subject to change without notice.Check local codes. Printed 07/16/2019 Small Sunr 3-6 Ton Page:3 YORK® Package York Single Package R-410A Air Conditioner Project Name: Rite Aid 5355 Tigard OR REV 2 Unit Model#: ZE060K10B4A1AAA1A1 Quantity: 1 System: ZE060K10B4A1AAA1A1 Cooling Performance Total gross capacity 61.1 MBH Sensible gross capacity 45.4 MBH .��� Total net capacity 58.0 MBH t Sensible net capacity 42.3 MBH Seasonal Efficiency(at ARI) 14.00 SEER Efficiency(at ARI) 11.80 EER Ambient DB temp. 95.0 °F , t f` Entering DB temp. 80.0 °FIx Entering WB temp. 67.0 °F . . Leaving DB temp. 59.0 °F • ,, Leaving WB temp. 57.3 °F Power Sound poweut rw/o blower) 4 82 dB(A) A.e .kW , /, Refrigerant Refrigerant type R-410A Sys1 6 lbs 6 oz --- • '-� Gas Heating Performance 5 Ton Entering DB temp. 60 °F Heating output capacity(Max) 79 MBH • York Units are Manufactured at an ISO 9001 Registered Facility and Each Supply air 2000 CFM Rooftop is Completely Computer-Run Tested Prior to Shipment. Heating input capacity(Max) 100 MBH Unit Features Leaving DB temp. 96.6 °F Air temp.rise 36.6 °F • Single Stage Low Nox Gas Aluminum Steel SSE 80.0 % • Single Stage Cooling Stages 1 • 100 MBH Input Supply Air Blower Performance • Unit Cabinet Constructed of Powder Painted Steel,Certified At 750 Hours Supply air 2000 CFM Salt Spray Test(ASTM B-117 Standards) Ext.static pressure 0.05 IWG • Either Supply and/or Return can be Field Converted from Vertical to Addl.Unit Losses(Options/Accessories) 0.15 IWG Horizontal Configuration without Cutting Panels. Blower speed 910 RPM • Full Perimeter Base Rails with Built in Rigging Capabilities Max BHP of Motor(including service factor) 1.73 HP • Scroll Compressor Duct location Bottom Motor rating 1.50 HP • 1.5 HP Standard Static Belt Drive Blower Actual required BHP .97 HP • Unit Ships with 1"Throwaway Filters Power input 0.90 kW • Solid Core Liquid Line Filter Driers Elevation 0 ft. • Replacement Filters:2-(15"x 20"x 1"or 2")and 1-(14"x 25"x 1"or 2"). Drive type BELT Unit accepts 1"or 2"wide filters. Requires field-supplied drive true • Single Point Power Connection Electrical Data • Through-the-Curb and Through-The-Base Utility Connections Power supply 460-3-60 • Short Circuit Current:5kA RMS Symmetrical Unit min circuit ampacity 14.1 Amps • Microchannel All Aluminum Condenser Coil,Copper tube/Aluminum fin Unit max over-current protection 20 Amps Evaporator Coil Dimensions&Weight • Galvanized Steel Drain Pan Hgt 33 in. Len 83 in. Wth 45 in. • Standard Access Doors Weight with factory installed options 702 lbs. BAS Controller Clearances • Smart Equipment Controller including Discharge Air,Return Air,and Outdoor Right 24 in. Front 32 in. Back 36 in. Air Temperature Sensors. Top 72 in. Bottom 0 in. Left 36 in. i Standard Unit Controller: Smart Equipment Control Board Note: Please refer to the tech guide for listed maximum static pressures • An Integrated Low-Ambient Control,Anti-Short Cycle Protection,Lead-Lag, A® Fan On and Fan off Delays,Low Voltage Protection,On-Board Diagnostic nw CERTIFIED..nuALiTv I and Fault Code Display.Allows all units to operate in the cooling mode down ..a, ., �a to 0°F outdoor ambient without additional components or intervention. • Safety Monitoring-Monitors the High and Low-Pressure Switches,the Freezestats,the Gas Valve,if Applicable,and the Temperature Limit Switch on Gas and Electric Heat Units.The Unit Control Board will Alarm on Ignition Failures,Safety Lockouts and Repeated Limit Switch Trips. Warranty • One(1)Year Limited Warranty on the Complete Unit • Five(5)Year Warranty-Compressors and Electric Heater Elements • Ten(10)Year Warranty-Aluminized Heat Exchanger Information is subject to change without notice.Check local codes. Printed 07/16/2019 • Small Sunline 3-6 Ton Page:4 YORK® Package York Single Package R-410A Air Conditioner Project Name: Rite Aid 5355 Tigard OR REV 2 Unit Model#: ZE060K10B4A1AAA1A1 Quantity: 1 System: ZE060K10B4A1AAA1A1 Factory Installed Options ZE060K10B4A1AAA1A1 Equipment Options Option(s) Selected York Small Sunline Single Packaged R-410A Air Product ry Categ o ZE Conditioner 11.8 EER/14.0 SEER 5 Ton Nominal Cooling Capacity: 060 Single Stage Cooling I 1 r. Single Stage Low Nox Gas Aluminum Steel Heat Type and Nominal Heat Capacity: K10 100 MBH Input Blower Option: B 1.5 HP Standard Static Belt Drive Blower Voltage: 4 460-3-60 ,, Outside Air Option: A `' Service Options: 1 ., , f'. Sensor Options: A � ,t Smart Equipment Controller including Discharge Air, Controls: A Return Air,and Outdoor Air Temperature Sensors. Microchannel All Aluminum Condenser Coil, Copper Refrigeration: A tube/Aluminum fin Evaporator Coil Additional Options: 1 1"Throwaway Filters Galvanized Steel Drain Pan Cabinet Options: A Standard Access Doors x Product Generation: 1 "� � Field Installed Accessories O 1 BD0401 -Burglar Bars(25.0 lbs) 0 1 GP0401 -Gas Piping Kit for 0 1RC0442-Roof Curb- 12" High, O 1CG0401 -Coil Guard (11.0 lbs) Bottom Gas Supply Connection Flat, Uninsulated, Full Perimeter O 1 CV0402-Concentric with External Shut-Off(includes: (Shipped Knocked Down)(78.0 Diffuser,Flush Mount,18RD Internal gas pipe,fittings, gas cock lbs) &panel gaskets)(5.0 lbs) 0 1 RC0465- Roof Curb-8" High, O 1 CV0411 -Concentric9 Diffuser,Side Discharge,18RD 0 1HG0413-Hail Guard Kit(51.0 Flat, Uninsulated, Full Perimeter (55.0 lbs) lbs) (Shipped Knocked Down) (67.0 0 1 LN0406- Low NOx Kit- lbs O 1 CV0419-Concentric ) Diffuser,Specialty,18X18 Required to reduce the emission 0 1WC0411 -Wooden Crate for O 1 FA0403- Manual O.A. Damper of nitrogen oxides below 40 extra protection during shipping with Hood Kit-0%to 35% nanograms per joule. and handling (302.0 lbs) Capability(9.0 lbs) 0 1 NP0440- Natural Gas to 0 2AP0402-Air Proving Switch (1.0 O 1 FA0404- Manual O.A. Damper Propane Conversion Kit(1-Stage) lbs) with Hood Kit-0%to 100% (1.0 lbs) 0 2DF0403- Dirty Filter Switch (1.0 Capability(15.0 lbs) 0 1RC0434- Roof Curb- 14" High, lbs) O 1 FE0405- Flue Extension Kit Flat, Uninsulated, Full Perimeter • 2EE04709024-Dry Bulb Low (25.0 lbs) (Shipped Knocked Down)(86.0 Leak Economizer(Hood Kit lbs) included for field assembly and installation) (50.0 lbs) Information is subject to change without notice.Check local codes. Printed 07/16/2019 Small Sunline 3-6 Ton Page:5 a YORK® Package York Single Package R-410A Air Conditioner Project Name: Rite Aid 5355 Tigard OR REV 2 Unit Model#: ZE060K10B4A1AAA1A1 Quantity: 1 System: ZE060K10B4A1AAA1A1 O 2EE04709124- BAS Low Leak 0 S1-03103516000-Temp& Economizer with 2-10VDC humidity sensor, 120mm x 80mm, Actuator w/o Barometric Relief LCD display, screw terminals, (50.0 lbs) warmer/cooler dial, JCI logo (0.4 O 2MD04700524 - Motorized O.A. lbs) Damper- Provides outdoor air 0 S1-03103517000-Temp sensor, intake when indoor fan is 120mm x 80mm, no display, no energized. Closes when fan shuts dial, screw terminals, no logo(0.4 off. (35.0 lbs) lbs) O 2SD04701724-Smoke Detector 0 S1-03103518000-Temp& Kit w/Mounting Hardware for humidity sensor, 120mm x 80mm, Supply or Return Air no display, modular jack, (Horizontal/Downflow) (16.5 lbs) warmer/cooler dial, JCI logo (0.4 O ASC Services-Charges for this lbs) Service are Applicable. 0 S1-03103519000-CO2 sensor, Application, Startup& 120mm x 80mm, no display, screw Commissioning (ASC)Services terminals or modular jack, no logo Available with Daily Fee Plus (0.2 lbs) Expenses. This Service Provides 0 S1-MP-PRTKIT-013- MAP a 90 Day DOA Benefit When (Multiple Access Portal) Gateway Completed by a Factory Certified Kit- Replacement MAP gateway Technician. Contact Your protective case, lanyard and Distributor, Dealer, or Sales communication cable. Use only to Representative. Distributors Can replace worn or damaged Call 1-877-874-7378 for an ASC components. (0.3 lbs) Quote. • S1-SE-COM1001-0- Field O S1-03102529000-Non- Installed Communication Card for Networking Wall Sensor—Allows Simplicity SE control. Can be field remote sensing and control from configurable for BACnet, N2 or single or multiple zones. (0.2 lbs) ModBUS MSTP(0.0 lbs) O S1-03102529004-Non- 0 S1-TBSU32P7S-Source 1 Networking Wall Sensor with Branded LX Series, Up to 4 Heat/ Over-ride button—Allows remote 2 Cool, Electronic 7 Day sensing and control from single or Programmable(1.2 lbs) multiple zones. Override allows Q S1-YK-MAP1810-0P- MAP setpoint to be overridden for 2 (Multiple Access Portal) Gateway- hour time period. (0.2 lbs) For use with SimplicitySE Control. O S1-03102529006- Non- (0.2 lbs) Networking Wall Sensor with Q S1-YK-MAP1810-05-Stationary Setpoint Adjustment and Over-ride MAP Gateway(Includes MAP Button—Allows remote sensing Gateway, Field Bus Adapter, and control from single or multiple Mounting Bracket and 100 to 240 zones.Allows setpoint to be VAC Power Supply). US- adjusted±5° F. Override allows compatible counties. (1.9 lbs) setpoint to be overridden for 2 hour time period. (0.2 lbs) O S1-03103489000-Temp sensor, 80mm x 80mm, LCD display, screw terminals, adjustable setpoint, JCI logo (0.1 lbs) O S1-03103490000-Temp sensor w/Economizer FDD, 120mm x 80mm, LCD display, screw terminals, adjustable setpoint, no logo(0.0 lbs) Information is subject to change without notice.Check local codes. Printed 07/16/2019 2 YORK® Small Sunline 3-6 Ton Package Page:6 York Single Package R-410A Air Conditioner Project Name: Rite Aid 5355 Tigard OR REV 2 Unit Model#: ZE060K10B4A1AAA1A1 Quantity: 1 System: ZE060K10B4A1AAA1A1 Consolidated Drawing 2 3 4 5 __ _ _____ P9 ." %I 12 3 14 15 I6 NOTES: U CENTER OF GRAVIT, I. COR OUTDOOR USE ONLY N OPERATING LOCATION (BASE Mc, 4 POINT CORNER LOADS(LBSS (BASE UNIT) 2. WEIGHTS SHOWN ARE FOR COOLING ONLY UNITS. MAGE 1 WEIGH) (LOS) N 3. MIN. CLEARANCES TO BE: '.. T (BASE UNIT! X r A 8 c D 8 RIGHT SIDE: 24 [639,6] 3 2E/ID 4(0(2131 34.5 (876,3] 18.25 1463,61 III (501 80(361 117 153) 762(73] LEFT SIDE: 24 [609,6] (LESS ECONOMIZER) "' 31.62 4 1E2tD 598(27)0 36 [914,47 :8.50[469,9] (39(63) 106(49] 751 7101 '98 1901 36 [914,41 (WITH ECONOMIZER) 1803,31 FRONT: 24 [609,6] (COOLING/ELECTRIC HEAT) 6.12 s IE/ZD 632[2871 31.5(952,5] 18.2 (462,31 139 1631 117 [sJ) ITI [78] 204[937 32 [812,8] (GAS HEAT) 1155,51 I 6 21/00 665(3021 35.5 (901.7] 17.75(450.6) 150(68] 114 1521 173 :781 228 1103) REAR: 12 [304,81 (LESS ECONOMIZER) 1.25 18.26 .,.--- I 3 XN/X( 610(21)) 38.3[912,8118.15(4'6,31 136 (621 119(540 165 .75) 190(867 36 [914,4] (WITH ECONOMIZER OR FIXED (184.0] [463,1] I AIR MOTORIZED DAMPER) I 4 XN/X1 616(2797 38.2 (970,3] 18.4 :467,47 135[fill 117 [531 169:771 195(88) TOP: 12 [1828,81 1.80 27.54 1 5 30/81 620(281] 1 38.6 (980,41 18 [457.27 132 1601 111[537 174 .19] 197 1892 BOTTOM: 0 [0] (45,87 [699,5] 4. FOR SMALLER SERVICE AND OPERATIONAL CLEARANCES CONTACT YOUR APPLICATION ENGINEERING DEPARTMENT. + 1R 5. DOWNFLOW DUCTS DESIGNED TO BE ATTACHED TO ACCESSORY ROOF CURB ONLY. IF UNIT IS MOUNTED SIDE SUPPLY, IT H IS RECOMMENDED THAT THE DUCTS ARE SUPPORTED BY -5.89 CROSS BRACES, AS DONE ON ACCESSORY ROOF CURBS 5 cl 1149,6] H 6. SIDE DUCT FLANGES ARE 0.815' [22,21 HIGH. [140 01-I A BOTTOM DUCTS DO NOT HAVE FLANGES. 1 B 1. MINIMUM CONDENSATION TRAP HEIGHT SHALL BE 1.5 TIMES f-' ` THE LOWEST NEGATIVE STATIC. --L--- 8. DIMENSIONS IN [ I ARE IN MILLIMETERS OR KILOGRAMS. .� 23 r 9. OPTIONAL COIL GUARD, GAS HEAT, ECONOMIZER HOOD, ;i 12.26 vl I 11.50 i G DISCONNECT SWITCH, CONVENIENCE OUTLET, AND POWER WIRING 1q [311,3] , PI [292,1] OUTLET/INLET HOOD SHOWN. BOTTOM ENTRY •N,__ ___! e1 1 ��� G �TTOM [50,8] -„l & 4'' 1750 EXCEPT XN/XT (HEAT PUMP) UNITS, 1111111111. o/A (16,2] [292.11 tI01,bj� • } IIIIIIIIII ECONO7 . 3.00 F -► DIRECTION OF AIRFLOW f 8 23 Y x 1111116111 RETURN ' LSD 9.12 F S CENTER OF GRAVITY :209,2]_/),/5:/#1 20 ,2] j NlINl11l 0(6 [292 II INI41 SUPPLY r [485,8] C G 11.06 6 48 c 11 ................... [281,0] [164,71 6 50 CONTROL WIRING BOTTOM ENTRY �-32 09 AS SUPPLY BOTTOM ENTRY 01.50 [38,1] N.O. (165,11 L 4.62 F 00.88 [22,21 [815,21 (0.50 [12,71 NPT AT GAS VALVE 17.50 7.62 [117,51 X [444,5'. [193,6] E ECONOMIZER HOOD VENT AIR OUTLET HOOD 17.50 31.62 (OPTIONAL) 150,00 K.O. - [444,5] [203 2' [50,0] OMBUSTION AIR INLET HOOD DISCONNECT SWITC REAR.D'ARTIAL VIEW) COVER (OPTIONAL) _ 8 (RAIN WOO, NC , AN .6 i3.S VIEW) I FILTER w GAS -- IIIIIIII1toIIliiNIN IIIIIIIIIIIIIIIII1111IIIINIIIIEIIIII111116111I11611111161 D ASCE55 HEAT COMP IIIIIIIIIIINIIIV, 810 ER CONVENIENCE CUTLET AC SS ACCESS 1 S IINIIIIIIIINIIIIIIIIIIIIIIIII6111IIIIIIIII611111111111111 I ACCESS COVER (OPTIONAL) BLOWER o mum NIIIIIIIIIIINIIIINIIIIINIIfII11lIINNI1lIN111111N1 ss35 ACC SS �I II�IIIIIIIIIIIIIIIIIN . 32.55 11IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIINIIIIIIIIIIIIINII I1 210.89 K.O. [826,7] 11 c [z2 2] p1 I ■ IIIIIIIIIIIIIIIIIIIII II1IIIIII11111IIIIIIIIIIIIIIiIIII1111IIIIIIII11I1111�1 IIIIIIII F1 II�IIIIIIgIIIINNIIII' IIIIIIIIIIIIIIIIIINIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII C - - IBIN„ ,..,,, x. Ir lrr,NwlaiQf� c I)_N�FFFIY�9��.�11�(IA/�. r-E I I -- 3.78 - 4.38 6.94 18.58 J. / [96,01 [111.1] [176,21 j,.. (471,91 -31.89 - �AS SUPPLY ENTRY .I. ,,,',] 8 19.61 (4 [810,0] 01.63 1,41 © �� � OIL GUARD (OPTIONAL) 0.75 119,11 [499,7] 2.55 82.19 RICHT_VNEN( 8 PVC FPT [64,7] [2087,6] EY]iT VENT COND.'ORA IN fR DALE REVISION RECORD EC NO DR CM ENG (x742 2603E P8OIACTIOA s a 887£20 o x[ WCE*1s vpnT uAWolxi OrTN'iei oe o sciose exi a T¢" � SYFT0 Axe XEY *ex...TT(x,IonnoN COM. V BE PDP-S1D-01 PER �®,VEW A 12-21.10 NEW DRAWING --- LC RDH--- a• ,o ora .rxouT x BE PDr STDNI B 09.08-11 CHANGED OPERATING 6 CORNER WEIGHTS FOR 3,4 8 51(GEN 2) 19126 LO RCf AMC -{,--_---7� MENAMEBANNINE PER 2SxE SE 5'009 MATERIAL C II 25 14 ADDED ZERO 8XN,XT MODELS ��� `�-1 [62+�[r ueuss necnlx sr[c nm. SUBMITTAL DWG. SM SUNLINE. TYPE NOT APPLICABLE 30683 LO RDH NMC 3 G TONS Ew u[c NOR APPLICABLE A D 07-30-I8 ADDED 26/20 6 TON MODEL 8 REMOVED OBSOLETE DATA 60489 SND LOP CB wrt 011[rI::'!:::: t.i 511E DRN [42M 12.1110 A P[2[[0u xti. t o1 A CM 12188162 I!-&.12 (2x22 PLACE Mau[: *Dlo JOHNSON CONTROROG L REV 0 LS t UNITARY R UST-SSL- 32 X(6 0ix[ulas [IP WKS A Y PR DU S GRO I PRODUCTS JP IODF H _SEWART PONT NT SCALE PAINT NORMAN, ON 73069 ....NO.NT of I. 1 2 3 4 5 6 ' 8 9 10 11 12 :3 14 15 16 Information is subject to change without notice.Check local codes. Printed 07/16/2019 F rayoRK® Small Sunline 3-6 Ton Page:7 Package York Single Package R-410A Air Conditioner Project Name: Rite Aid 5355 Tigard OR REV 2 Unit Model#: ZE060K10B4A1AAA1A1 Quantity: 1 System: ZE060K10B4A1AAA1A1 Component Location Component Location Gas/Electric Power Ventor Motor 114th 20 Gauge Aluminized --" ` Po Purge Cyde Steel Tubular Heat Exchanger Y ___.._ Alk HACR ((lli0(<''l-= 1))))))))))� mpresor Breaker • , Economizer Hood fit ,^.� JP46% .✓" Illlilllli�lllil/ • IIIIlIIIIIIIIlIlr \\\ 7–r.,,,.,, t`' Highly Effidenl \ L '! 1111I1111111�� Enhancetl Copper !III TubelEnhar¢etl f- �V I,t II�I� Aluminum Fin Knockout 11.- rrrri f ,,a. . OrFor Side rrr e�. e�.. Y Micro-Channel Trik f� �� aemm,mPover Entry ! - -��� I. 1-ion-be/Aluminum Slide-In 11 i ._te l Fin Conuentser Economizer Ilij} T.y u� r . I I- r r .r+ ut qIA {{{ �_, Shaka o r' �I • •• OM...t _, Detector `' " HO �' ~ ..� ( I 4 ,.c_____ "��5'-'Full Perimeter Baser-ails : .rrFEw{L]1e �r Mhth Forklift Slots And 3t1'PVC Female , ►4 —� Lifting HOIes Condensate Drain y Knockout For Side GFG _ Gas Supply Entry Convenience Outlet i ''' Simplicity Liter" is Or Simplicity SE Knockout VV� Belt Dnve Or Control Board For Side Direct Drive Control Entry Blower Information is subject to change without notice.Check local codes. Printed 07/16/2019 . Ea yoR K. Small Sunline 3-6 Ton Page:8 Package York Single Package R-410A Air Conditioner Project Name: Rite Aid 5355 Tigard OR REV 2 Unit Model#: ZE060K10B4A1AAA1A1 Quantity: 1 System: ZE060K10B4A1AAA1A1 Typical Application ROOF JACK \rigai ..\ : INSTALLATION i 0 o i I 1 a 7.., I,.. 4 F ROOF CURB i ___, = I I , — ......— / INSTALLATION • —..- ,.......* 1 I i 1 I I 1 i t 1 1 1 1 I Jill 1 II 1 1 1 1 1 1 1 1 1 1 1 1 1 L 1 1 ' 1 SLAB ON GROUND 1 1 11111 r INSTALLATION 1 1 I ' I 1 / 1 1 I 1 I 1 I 1 1101111"00...11.1111Th 0 00_ IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIBUIIIIII • or 4444 h* _it.ii.LA .......4.1110,0 BrINUNKmN00000somoiom . , -'•=1;? , * * • #(0', —- ------- FIELD-SUPPLIED !...00 • - DISCONNECT SWITCH 41 r lrii' •:::;, 09/,''•. ! : I 0 -IIIIIIIL.- ' ' Jr- • ...44/44.,:14 0 "..,P":4"%, • 4 . , 4 .., :id.,... ..,..., r, ...... „...„,„,- ,,,...„..:..,. ........,, .... : liet-- _,'-'"-I°* --...• , 107, - 0-el.. --;--•.-"' ”:'1611,%.-- 0,.„... ' ' .447.'''.41, i.: ' l'-':-•`:-- : ,r.'... _,.--------- , .„.V1 ' •-:'.1.-zt' . ..,"".. ^'I , .,`„ 1-....... ___----1 ... DRIP LEG -';'-**2- ' ',;re,.•.:'-"--- ...-•". - .1 0 f `-`--...77,,,:„...t . • -• I ••••• . '. I r irolti*eritti,,.--;---""-- 11." ---# ,,••• . , .1 ' ---.- .-',,4....,:- i. , .1, ,....i. • ....,,. ... 1 _ ii. 1 0-;er I .. , 1 i 4 t..../‘. 1 .1:4.:..-5--::41.tr.-- 110 MANUAL .C--I iP4irlli •str,.....•.._ I' .:*,41 1 • .000000 11144•11..._ a I GAS SHUT-OFF ROOF CURB 1 VALVE CONDENSATE "1410 "..e#1-.-._ 1„,,," 'iposioiliiiis *xis." . IN.4000,000.1....0011H1. 1 eine 0000 iirs."-11 : 1 111 i• 1 - I \ TRAP ".1 TO GAS SUPPLY LINE I SUPPLYAIR TO CONTROL WIRING POWER TO INDOOR RETURN AIR SUPPLY THERMOSTAT DUCT Information is subject to change without notice.Check local codes. Printed 07/16/2019 YORK® Small Sunline 3-6 Ton Page:9 Package York Single Package R-410A Air Conditioner Project Name: Rite Aid 5355 Tigard OR REV 2 Unit Model#: ZE060K10B4A1AAAIA1 Quantity: 1 System: ZE060K10B4AIAAAIA1 Typical Field Power and Control Wiring TYPICAL POWER WIRING CONTACTOR 0 G FIELD-SUPPLIED tYQ (9 _ CONTACTOR DIS_CO_NNEC_T _ ,, i i i r-"_ SINGLE •0• FIELD-SUPPLIED _i L -I--O-",';¢-r- PHASE =T �� RC1 DISCONNECT -4—-0-" 0--'--POWER ; 9 �'' r - GROUND L • SUPPLY y ; -0--i f}_ _ THREE LUG PHASE REFER TO THE ELECTRICAL DATA GROUND L L .J {0--'-o--L- POWER TABLES TO SIZE THE DISCONNECT LUG I I SUPPLY SWITCH,OVER CURRENT L J PROTECTION AND WIRING. TYPICAL COOL/HEAT CONTROL WIRING COOLING ONLY(24 VOLT THERMOSTAT) COOLING/HEATING (24 VOLT THERMOSTAT) THERMOSTAT' UNIT TERMINAL THERMOSTAT' TERMINALS STRIP TBI TERMINALS ��°JJ 8---------I trl 0 UNIT TERMINAL STRIP TB1 24 VOLT ADD YC ----------- Yt TRANSFORMER JUMPER La_ Y2 : 0_ 0 2 VOLT /'� TRANSFORMER GF ---- --• -i G 1 Y2 O Wt 1 E 124 VOLT THERMOSTAT.TO CONTROL THE ECONOMIZER ON SECOND 0 STAGE COOLING,USE A 2 STAGE COOLING THERMOSTAT. 0------0— COOLING/HEATING (ELECTRONIC THERMOSTAT) 0 MULTI STAGE '24 VOLT THERMOSTAT.TO CONTROL THE ECONOMIZER ON THE SECOND THERMOSTAT1 STAGE COOLING OR TO HAVE AN ELECTRIC HEAT ACCESSORY WITH TWO STAGES OF HEAT,USE A 2 STAGE COOL AND HEAT THERMOSTAT. TERMINALS UNIT TERMINAL 0 STRIP TB1 24 VOLT JUMPER ,`�ICE -----------------® TRANSFORMER COOLING/HEATING(ELECTRONIC THERMOSTAT) ® w--2--•--NM SINGLE STAGE ..... r ®------------------® THERMOSTAT' 4 © 3------ TERMINALS UNIT TERMINAL MI------------ - - STRIP TB1 ILED 1 •------------® ADD LED 2 NOT ;-_----_ GEC JUMPER ® r'---- COM USED 4 :��y JUMPER i Q ADD 1E11- - Mill © TO REMOTE SENSOR 24 VOLT © IF USED TRANSFORMER 'ELECTRONIC PROGRAMMABLE THERMOSTAT TYPICAL. 'ELECTRONIC PROGRAMMABLE THERMOSTAT TYPICAL.TO CONTROL THE ECONOMIZER ON SECOND STAGE COOLING,USE A 2 STAGE COOL AND SECOND STAGE COOLING IS NOT REQUIRED ON UNITS LESS ECONOMIZER. HEAT THERMOSTAT. SECOND STAGE HEATING IS ONLY REQUIRED ON UNITS WITH A TWO STAGE ELECTRIC HEATER OR 2 STAGE GAS HEAT. •REMOVE JUMPER J2 FROM TERMINALS 4 AND 9 ON JUMPER PLUG CONNECTOR P6 ON UNITS WITH ECONOMIZER.TERMINALS Al AND A2 PROVIDE A RELAY OUT-PUT TO CLOSE THE OUTDOOR ECONOMIZER DAMPERS WHEN THE THERMOSTAT SWITCHES TO THE SET-BACK POSITION. Information is subject to change without notice.Check local codes. Printed 07/16/2019 Page: 10 Date 07/16/2019 Project Name Rite Aid 5355 Tigard OR REV 2 Project Number Client/Purchaser Guide Specification Summary Page Product Series Models and Unit Tags Small Sunline 3-6 Ton Package ZEO60K10B4A1AAA1A1 Information is subject to change without notice.Check local codes. Printed 07/16/2019 • rig YORK® Guide Specification for Page:11 York Sunline GENERAL UNIT CABINET York Sunline units are convertible single package units. Unit cabinet shall be constructed of galvanized steel, with Although the units are primarily designed for curb exterior surfaces coated with a non-chalking, powdered mounting on a roof, they can also be slab-mounted at paint finish, certified at 750-hour salt spray test per ground level or set on steel beams above a finished roof. ASTMB117 standards. Indoor blower section shall be Cooling only, cooling with gas heat, cooling with electric insulated with a minimum 1/2"thick insulation, coated on heat and heat pump with electric heat models are the airside. Aluminum foil faced insulation shall be used in available with a wide variety of factory mounted options the furnace compartment and be fastened with ridged and field-installed accessories to make them suitable for fasteners to prevent insulation from entering the air almost every application.All units are self-contained and stream. Cabinet panels shall be"large"size, easily assembled on full perimeter base rails with holes in the removable for servicing and maintenance. Full perimeter four corners for overhead rigging. Every unit is base rails shall be provided to assure reliable transit of completely piped, wired, charged and tested at the equipment, overhead rigging and proper sealing on roof factory to simplify the field installation and to provide curb applications. Disposable 1"filters shall be furnished years of dependable operation.All models (including and be accessible through a removable access door, those with an economizer)are suitable for either bottom sealed airtight. Units filter track shall be designed to or horizontal duct connections. Models with power accommodate either 1" or 2"filters. Fan performance exhaust are suitable for bottom duct connections only. measuring ports shall be provided on the outside of the For bottom duct, remove the sheet metal panels from the cabinet to allow accurate air measurements of evaporator supply and return air openings through the base of the fan performance without removing panels or creating air unit. For horizontal duct, remove the supply and return by-pass of the coils. Condensate pan shall be internally air panels on the rear of the unit. sloped and conform to ASHRAE 62-89 selfdraining standards. Condensate connection shall be a minimum of All non-Scroll compressors include crankcase heaters and 3/4" I.D.female and be a ridged mount connection. all compressors have internal pressure relief. Every refrigerant circuit includes a liquid line filter-drier, a INDOOR(EVAPORATOR) FAN ASSEMBLY discharge line high pressure switch and a suction line with The indoor fan shall be a factory installed direct-drive or a freezestat and low pressure/loss of charge switch.The beltdrive assembly that includes an adjustable pitch motor unit control circuit includes a 75 VA transformer, a 24-volt pulley. Job site selected brake horsepower(B.H.P.)shall circuit breaker and a relay board with a compressor not exceed the motors nameplate horsepower rating, plus lockout circuit, a terminal strip for thermostat wiring, plus the service factor. Units shall be designed not to operate an additional set of pin connectors to simplify the interface above service factor. Fan wheel shall be double-inlet type of additional field controls.All models are CSA listed. All with forward-curved blades, dynamically balanced to models include a 1-year limited warranty on the complete operate smoothly throughout the entire range of operation. unit. Compressors and factory installed electric heater Airflow design shall be constant air volume. Bearings shall elements carry a 5-year warranty.Aluminized steel and be sealed and permanently lubricated for longer life and Stainless steel tubular heat exchangers carry a 10-year no maintenance. warranty. DESCRIPTION OUTDOOR(CONDENSER) FAN ASSEMBLY The outdoor fan shall be of the direct-drive propeller type Units shall be factory-assembled, single packaged, Electric Cooling/Gas Heat, Electric Cooling/Optional (3-5 ton units), discharge air vertically, have aluminum Electric Heat, Heat Pump/Optional Electric Heat and are blades riveted to a corrosion resistant steel spider bracket designed for outdoor mounted installation and shall be dynamically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with The 3 ton, 4 ton, and 5 ton units shall have minimum permanently lubricated bearings, internally protected SEER rating of 14.0 with heat pumps having a 8.0 H.S.P.F. against overload conditions and staged independently. The 6 ton units shall have a minimum IEER rating of 14.2. REFRIGERANT COMPONENTS They shall have built-in field convertible duct connections for down discharge supply/return or horizontal discharge Compressors: supply/return, and be available with factory installed options or field installed accessories. The units shall be a. Shall be internally protected with internal high- factory wired, piped, charged with R-410A refrigerant and pressure relief and over temperature protection. factory tested prior to shipment.All unit wiring shall be b. Shall have internal spring isolation and sound both numbered and color coded.All units the cooling muffling to minimize vibration and noise, and be performance shall be rated in accordance with DOE and externally isolated on a dedicated, independent AHRI test procedures. Units shall be CSA listed, classified mounting. to ANSI Z21.47, UL 1995/CSA No. 236 standards. Information is subject to change without notice.Check local codes. Printed 07/16/2019 YORK® Guide Specification for Page:12 York Sunline Coils: j. Control board shall monitor each refrigerant safety a. Evaporator coils shall have aluminum plate fins switch independently. mechanically bonded to seamless internally enhanced k. Control board shall retain last 5 fault codes in non copper tubes with all joints brazed. Special Phenolic volatile memory which will not be lost in the event of a coating shall be available as a factory option. power loss. b. Evaporator coils shall be of the direct expansion, draw- UNIT OPERATING CHARACTERISTICS thru design. c. Condenser coils shall have aluminum plate fins Unit shall be capable of starting and running at 125°F mechanically bonded to seamless internally enhanced outdoor temperature, exceeding maximum load criteria copper tubes with all joints brazed or Micro-Channel of AHRI Standard 210/240. The compressor, with aluminum tube, aluminum fins. standard controls, shall be capable of operation down to d. Condenser coils shall be of the direct expansion, draw- 0°F outdoor temperature. thru design. ELECTRICAL REQUIREMENTS Refrigerant Circuit and Refrigerant Safety Components All unit power wiring shall enter unit cabinet at a single shall include: factory provided location and be capable of side or bottom entry, to minimize roof penetrations and avoid a. Independent fixed-orifice or thermally operated unit field modifications. Separate side and bottom expansion devices. openings shall be provided for the control wiring. b. Filter drier/strainer to eliminate any moisture or foreign STANDARD LIMITED WARRANTIES matter. c. Accessible service gage connections on both suction • Compressor 5 Years and liquid lines to charge, evacuate, and measure • Heat Exchanger 10 Years refrigerant pressure during any necessary servicing or • Factory Installed Electric Heat Element 5 Years troubleshooting, without losing charge. • d. The refrigeration system shall provide at least 15°F of Other Parts 1 Year sub-cooling at design conditions. ADDITIONAL FACTORY INSTALLED OPTIONS Unit Controls: • BAS Controls a. Unit shall be complete with self-contained low-voltage control circuit protected by a resettable circuit breaker FIELD INSTALLED OPTIONS on the 24-volt transformer side. b. Unit shall incorporate a lockout circuit which provides • Barometric Relief Damper—This damper accessory reset capability at the space thermostat or base unit, can be used to relieve internal building air pressure on should any of the following standard safety devices trip units with an economizer without power exhaust. This and shut off compressor. accessory includes a rain hood, a bird screen and a c. Loss-of-charge/Low-pressure switch. fully assembled damper. With bottom duct connections, the damper should be mounted over the d. High-pressure switch. opening in the return air panel. With horizontal e. Freeze-protection thermostat, evaporator coil. ductwork,the accessory should be mounted on the f. Unit shall incorporate"AUTO RESET"compressor return air duct. over temperature, over current protection. g. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. h. Unit control board shall have on-board diagnostics and fault code display. i. Standard controls shall include anti-short cycle and low voltage protection, and permit cooling operation down to 0°F. Information is subject to change without notice.Check local codes. Printed 07/16/2019 Page:13 Date 07/16/2019 Project Name Rite Aid 5355 Tigard OR REV 2 Project Number Client/Purchaser Control Summary Page Control Models and Unit Tags Standard Simplicity Control ZE06OK10B4A1AAAIA1 Information is subject to change without notice.Check local codes. Printed 07/16/2019 LLig ig ySSE Guide Spec Page: 14 23 09 23 Direct-digital Control system for HVAC 23 09 23. 13 Decentralized,Rooftop Units: 23 09 23. 13.A. Unit Control Board 1. ASHRAE 62-2001compliant. BTL certified. 2. Shall accept 20-30 VAC input power,50/60Hz. 24 VAC nominal. 3. Operating temperature range from-40F to 158F; 10-90%RH(non-condensing UI),and-4F to 158F; 10-90%Rh(non- condensing),with a storage temperature range from-40F to 194F;5-95%RH(non-condensing). 4. Shall include an option of and Economizer microprocessor controller which communicates directly with the Unit Control Board and has 8 Analog outputs,2 Analog inputs,2 Binary outputs,3 Binary outputs. 5. Controller shall accept the followinginputs:space temperature,return air temperature sensor,setpointadjustment,outdoor air temperature,indoor air quality,outdoor air quality,indoor relative humidity,compressor lock-out,fire/smoke shutdown,single and dual enthalpy,fan status,remote time clock,SA Bus communicated temperature/humidity/CO2 values from Network sensors, FC Bus Network Overrides for space temperature,outdoor air temperature,space humidity,outdoor air quality,Indoor air quality, System purge. 6. Shall accept a single CO2 sensor or multiple CO2 sensors networked together via communication bus in the conditioned space,and be Demand Control Ventilation(DCV)ready. 7. Shall provide the following outputs:economizer,fan,cooling stage 1,cooling stage 2,heat stage 1,heat stage 2,heat stage 3/ exhaust/reversing valve/dehumidify/occupied. 8. Unit shall provide surge protection for the controller through a circuit breaker. 9. Shall be Internet capable,and communicate at a Baud rate of 38.4K or faster. 10. Shall have an LED display independently showingthe status of activity on the communication bus,and processor operation. 11. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit should any of the following standard safety devices trip and shut off compressor. If any of these safety devices trip,the LCD screen will display alarm message indicating the specific safety device that caused the lockout. a. Loss of charge/Low-pressure switch. b. High-pressure switch. c. Freeze condition sensor on evaporator coil. 12. Unit control board must support each usage case: a. Conventional thermostat with low voltage input terminals for easy installation b. Communicating network sensors in the occupied space to provide feedback on space conditions for unit control board to compare with associated setpoints c. Communication via BACnet MS/TP, Modbus RTU, N2 protocols for integration into a building automation/management system 13. Anti-short cycle and low voltage protection features included. 14. Internal occupied/unoccupied scheduling 15. Unit control board shall permit cooling operation down to a selectable value as low as 0 degrees F. 16. Shall allow for start-up,commissioning,troubleshooting, parameter adjustment,setpoint adjustment via onboard display and navigable menu with no additional interface tool or controls technician required. 17. The unit control board shall run a self-test diagnostics algorithm at startup that operated the cooling cycle, heating cycle,fan operation.A status report shall be provided upon completion of the diagnostic self-test. 18. Utilize any wi-fi enabled smart device to access the HVAC or multiple HVAC units if communication wiring between them is present(FC Bus or SA Bus). Remote access shall allow complete ability to perform start-up,commissioning, troubleshooting,parameter adjustment,setpoint adjustment. 19. Local embedded trending and scheduling.Trending data and occupancy scheduling predefined from the factory. Occupancy schedule to be modified via control board joystick menu navigation and remotely using a smart device (cellular phone, laptop,tablet) 20. A menu on the onboard screen shall display the unit status and allow changing parameters where applicable.These include but are not limited to: a. Demand Ventilation Mode—enable or disable b. Operational Setpoint—display current value c. Supply Air Temperature(SAT)—display current value d. Return Air Temperature(RAT)—display current value Information is subject to change without notice.Check local codes. Printed 07/16/2019 YORK® SSE Guide Spec Page:15 e. Operational Supply Humidity(OprSH)—display current value as provided by a 0-10VDS input, SA Bus Network Sensor,or FC Bus communicated value f. Return Air Humidity(RAH)—display current value g. Operational outdoor Air Temperature(OprOAT)—enthalpy calculated from OAH 0-10VDC input to Economizer board and OprOAT only if economizer is present h. Operational Outdoor Air Humidity(OprOAH)—the buffered outdoor air humidity. May be from economizer boards OAH 0-10VDC input or FC Bus communicated value i. Operational outdoor Air Quality(OprOAQ)—the buffered outdoor air quality in use. May be from economizer boards OAQ 0-10VDC input or FC Bus communicated value j Operational Indoor Air Quality(OprIAQ)—the buffered indoor air quality in use. May be from economizer board IAQ 0-10VDC input, SA Bus Network Sensor,or FC Bus communicated value 21. A menu shall display and allow modification to the following operations and settings: a. HVAC Zone Fan b. Cooling c. Heating d. Economizer e. Demand Ventilation f. Power Exhaust g. Sensors h. Network 22. A menu shall display and allow modification to the following operations and settings: a. HVAC Zone—Occupied status b. Indoor Fan status c. Cooling status d. Heating status e. Economizer indication whether free-cooling is available or not f. Enabling or disabling of Demand Ventilation g. Power Exhaust 1) Enable/disable hot-gas reheat if available 2) Warmup/Cooldown 3) Title 24 Load Shed 4) Defrost 23. A menu shall display and allow modification to the following operations and settings: a. Firmware version(of UCB, Economizer,other peripheral boards) b. Setting time zone c. Network information 1) Device name that will appear on the FC Bus 2) Selection of communication protocol 3) Operational Baud Rate 4) Device ID 24. A menu shall display and allow modification to the following operations and settings: a. Version of firmware b. Ability to Load new firmware c. Create a backup file of the firmware and parameter setting via USB port d. Restore factory default parameter values and setup e. Full and Partial Cloning of parameter setpoints from or to other units f. Data trend exporting 25. A menu shall display and allow modification to the following operations and settings: Information is subject to change without notice.Check local codes. Printed 07/16/2019 a YORK® SSE Guide Spec Page: 16 a. Unit serial number, model number and name b. Ability to reset Lockouts c. Controller name d. Displays the current values of all setpoints in use e. Displays all current values for the indoor and outdoor zones f. Displays current values related to: 1) Indoor Fan 2) Cooling 3) Heating 4) Heat Pump operation 5) Economizer operation 6) Power Exhaust 7) Demand Ventilation 8) Air monitoring station 9) Hot Gas Reheat 10) Smoke Control g. Current information for inputs; including 1) Sensors 2) Coil Sensors 3) Thermostat 4) Binary Inputs 5) Unit Protection 6) Network Inputs 7) All outputs(relay and binary) h. Self-Test 1) A patented self-test system that runs through a series of algorithms to provide a report of all functioning characteristics of the system at time of startup and commissioning. 23 09 23. 13.B. Auxiliary Control Boards 1. ASHRAE 62-2001 compliant.BTL certified. 2. Economizer controller CEC Title 24 Compliant a. Display alarms if the following occur 1) Economizer is economizing when conditions do not support 2) Economizer is not economizing when conditions do support 3) Damper Stuck 4) Excess Outdoor Air 5) Failed Sensor 3. Refrigeration Fault Detection&Diagnostics a. There is insufficient refrigerant in any circuit b. There is excessive refrigerant in any circuit c. There is excessive refrigerant flow d. There is insufficient refrigerant flow(restriction) e. Inefficient compressor f. Insufficient High-side heat transfer g. Excessive High-side heat transfer(low ambient control problem, low AP) h. Insufficient Low-side heat transfer i. Excessive Low-side heat transfer Information is subject to change without notice.Check local codes. Printed 07/16/2019 YORK® SSE Guide Spec Page:17 j. Sensor fault-The liquid temperature is greater than the condenser temperature(Could also be triggered if refrigerant level is very low in the system) k. Sensor fault-Sensor data is not available I. The unit is off m. The ambient temperature is too low n. The ambient temperature is too high o. The return air wet-bulb temperature is too low p. The return air wet-bulb temperature is too high q. Sensor fault-The condensing temperature is lower than the ambient temperature(Could also be triggered when the condenser is wet) r. The suction line temperature is less than the evaporator temperature s. The evaporator temperature is greater than the ambient temperature t. The liquid temperature is lower than the ambient temperature u. Sensor fault-Suction temperature or ambient temperature is invalid v. Sensor fault-The return air dry-bulb or wet-bulb temperature is invalid w. Sensor fault-The liquid pressure or suction pressure is invalid x. Sensor fault-The suction line temperature is invalid y. The return air dry-bulb temperature is too low z. The return air dry-bulb temperature is too high aa. The Efficiency Index is below 75%of ideal bb. The Capacity Index is below 75%of ideal 23 09 23. 13.0 Remote Accessibility: 1. ASHRAE 62-2001 compliant. BTL certified. 2. Provide the ability to adjust parameter values, setpoints, limits remotely 3. Connectivity to an Ethernet network via static IP address or Dynamic Name Server(DNS) 4. Allow a maximum of 100 devices on the same FC bus trunk and accessed by one remote device Information is subject to change without notice.Check local codes. Printed 07/16/2019 • Page:18 START-UP & SERVICE DATA INSTRUCTION COMMERCIAL PACKAGE UNITS 3.0 To 40.0 TONS START-UP CHECKLIST Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician: Signature: HVAC Contractor: Phone: Address: Contractors E-mail Address: Electrical Contractor: Phone: Distributor Name: Phone: WARRANTY STATEMENT This start-up sheet covers all startup check points common to all package equipment. In addition it covers essential startup check Johnson Controls/UPG is confident that this equipment will points for a number of common installation options.Depending operate to the owners satisfaction if the proper procedures are upon the particular unit being started not all sections of this startup followed and checks are made at initial start-up.This confidence is sheet will apply.Complete those sections applicable and use the supported by the 30 day dealer protection coverage portion of our notes section to record any additional information pertinent to your standard warranty policy which states that Johnson Controls/UPG particular installation. will cover parts and labor on new equipment start-up failures that Warranty claims are to be made through the distributor from whom are caused by a defect in factory workmanship or material,for a the equipment was purchased. period of 30 days from installation.Refer to current standard warranty policy and warranty manual found on UPGnet for details. EQUIPMENT STARTUP In the event that communication with Johnson Controls/UPG is required regarding technical and/or warranty concerns,all parties Use the local LCD or Mobile Access Portal(MAP)Gateway to to the discussion should have a copy of the equipment start-up complete the start-up. sheet for reference.A copy of the original start-up sheet should be A copy of the completed start-up sheet should be kept on file filed with the Technical Services Department by the distributor providing the equipment and a copy sent to: The packaged unit is available in constant or variable air volume Johnson Controls/UPG versions with a large variety of custom options and accessories Technical Services Department available.Therefore,some variation in the startup procedure will 5005 York Drive exist depending upon the products capacity,control system, options and accessories installed. Norman,OK 73069 Information is subject to change without notice.Check local codes. Printed 07/16/2019 Page:19 SAFETY WARNINGS The inspections and recording of data outlined in this procedure AWNING are required for start-up of Johnson Controls/UPG's packaged products. Industry recognized safety standards and practices Lethal voltages are present during some start-up must be observed at all times.General industry knowledge and checks.Extreme caution must be used at all times. experience are required to assure technician safety. It is the responsibility of the technician to assess all potential dangers and take all steps warranted to perform the work in a safe manner. By addressing those potential dangers, prior to AWARNINGJ beginning any work,the technician can perform the work in a safe manner with minimal risk of injury. Moving parts may be exposed during some startup checks. Extreme caution must be used at all times. NOTE: Read and review this entire document before beginning any of the startup procedures. DESIGN APPLICATION INFORMATION This information will be available from the specifying engineer full open position and the frequency drive is operating at 60 HZ. who selected the equipment.If the system is a VAV system the Do not proceed with the equipment start-up without the CFM will be the airflow when the remote VAV boxes are in the design CFM information. Design Supply Air CFM: Design Return Air CFM: Design Outdoor Air CFM At Minimum Position: Total External Static Pressure: Supply Static Pressure: Return Static Pressure: Design Building Static Pressure: Outside Air Dilution:Economizer Position Percentage: _ CFM: Supply Gas Pressure After Regulator W/o Heat Active Inches ADDITIONAL APPLICATION NOTES FROM SPECIFYING ENGINEER: Information is subject to change without notice.Check local codes. Printed 07/16/2019 Page:20 REFERENCE General pleted Inspection Com feted See Notes P Unit inspected for shipping,storage,or rigging damage 0 0 Unit installed with proper clearances 0 0 Unit installed within slope limitations 0 ❑ Refrigeration system checked for gross leaks(presence of oil) 0 0 Terminal screws and wiring connections checked for tightness 0 0 Filters installed correctly and clean 0 ❑ Economizer hoods installed in operating position ❑ 0 Condensate drain trapped properly, refer to Installation Manual ❑ ❑ Economizer damper linkage tight 0 0 Gas Heat vent hood installed 0 0 All field wiring(power and control)complete 0 0 Air Moving Inspection Completed See Notes Alignment of drive components 0 0 Belt tension adjusted properly 0 ❑ Blower pulleys tight on shaft, bearing set screws tight,wheel tight to shaft 0 0 Pressure switch or transducer tubing installed properly 0 0 Exhaust Inspection Powered 0 Barometric Relief 0 Completed See Notes Check hub for tightness 0 0 Check fan blade for clearance 0 0 Check for proper rotation 0 0 Check for proper mounting(screen faces towards unit) 0 0 Prove operation by increasing minimum setting on economizer ❑ 0 Economizer Inspection Standard 0 BAS❑ Completed See Notes CO2 sensor installed Yes 0 No 0 0 0 Check economizer setting(Reference SSE Control Board LCD menu location) ❑ ❑ Prove economizer open/close through SSE Board Setting 0 0 Reheat Mode Normal O or Alternate 0 Not Applicable 0 Humidity Sensor(2SH0401) Information is subject to change without notice.Check local codes. Printed 07/16/2019 Page:21 Operating Measurements -Air Flow Fan operates with proper rotation ID Fans❑ Exh. Fans 0 Cond. Fans❑ Pressure drop across dry evaporator coil(At maximum design CFM)1 IVVC External Static Pressure IWC Return Static Pressure IWC Supply Static Pressure IWC Supply Air CFM Using Dry Coil Chart CFM Final Adjusted Supply Air CFM2 CFM 1. Consult the proper airflow to pressure drop table to obtain the actual airflow at the measured pressure differential. 2. Was a motor pulley adjustment or change required to obtain the correct airflow? Was it necessary to increase of decrease the airflow to meet the design conditions? If the motor pulley size was changed,measure the outside diameters of the motor and blower pulleys and record those diameters here; Blower Motor HP FLA RPM Pulley Pitch Diameter Turns Out Final Turns Out Blower Pulley Pitch Diameter Fixed Sheave ELECTRICAL DATA T1 -T2 Volts T2-T3 Volts Control Voltage Volts T1 -T3 Volts Device Nameplate Measured List All Three Amperages Supply Fan Motors'2 AMPS AMPS Exhaust Motor(Dampers 100%) AMPS AMPS Condenser Fan#1 AMPS AMPS Condenser Fan#2(if equipped) AMPS AMPS Condenser Fan#3(if equipped) AMPS AMPS Condenser Fan#4(if equipped) AMPS AMPS Compressor#1 AMPS AMPS Compressor#2(if equipped) AMPS AMPS Compressor#3(if equipped) AMPS AMPS Compressor#4(if equipped) AMPS AMPS 1. VAV units with heat section-simulate heat call to drive VAV boxes and VFDAGV to maximum design airflow position. 2. VAV units without heat section-VAV boxes must be set to maximum design airflow position. Information is subject to change without notice.Check local codes. Printed 07/16/2019 Page:22 OPERATING MEASUREMENTS -COOLING Stage Discharge Discharge Liquid Line 2 Suction Suction Pressure Temp. Temp.1 Subcooling Pressure Temp. Superheat First # ° 0 # ° 0 Second(if equipped) # ° # ° Third(if equipped) #' ° ° # ° ° Fourth(if equipped) # 0 0 # ° ° Reheat 1st Stage # # ° ° 1. Liquid temperature should be taken before filter/drier. 2. Subtract 10 psi from discharge pressure for estimated liquid line pressure Outside air temperature °F db °F wb %RH Return Air Temperature °F db 0F wb %RH Mixed Air Temperature °F db °F wb %RH Supply Air Temperature °F db °F wb %RH REFRIGERANT SAFETIES Action Completed See Notes Prove Compressor Rotation(3 phase only)by gauge pressure 0 0 Prove High Pressure Safety,All Systems ❑ ❑ Prove Low Pressure Safety,All Systems 0 0 OPERATING MEASUREMENTS -GAS HEATING Fuel Type: 0 Natural Gas 0 LP Gas Action Completed See Notes Check for gas leaks 0 0 Prove Ventor Motor Operation ❑ 0 Prove Primary Safety Operation ❑ 0 Prove Auxiliary Safety Operation 0 0 Prove Rollout Switch Operation ❑ ❑ Prove Smoke Detector Operation ❑ 0 Stage 1 IWC 0 Manifold Pressure Stage 2(If Equipped) IWC 0 Stage 3(If Equipped) IWC 0 Supply gas pressure at full fire IWC 0 Check temperature riser 0 measured at full fire °F 0 j. Input X Eff.(BTU output) 1.08 X Temp.Rise Information is subject to change without notice.Check local codes. Printed 07/16/2019 Page:23 OPERATIONAL MEASUREMENTS -STAGING CONTROLS Verify Proper Operation of Heating/Cooling Staging Controls Create a cooling demand at the Thermostat, BAS System or Simplicity SE Verify that cooling/economizer stages are energized. ❑ Create a heating demand at the Thermostat, BAS System or Simplicity SE Verify that heating stages are energized. ❑ Verify Proper Operation of the Variable Frequency Drive(If Required) Verify that motor speed modulates with duct pressure change. 0 FINAL -INSPECTION Verify that all operational control set points have been set to desired value ❑ Scroll through all setpoints and change as may be necessary to suit the occupant requirements. Verify that all option parameters are correct Scroll through all option parameters and ensure that all installed options are enabled in the software and all 0 others are disabled in the software. (Factory software settings should match the installed options) Verify that all access panels have been closed and secured ❑ OBSERVED PRODUCT DIFFICIENCIES & CONCERNS: Information is subject to change without notice.Check local codes. Printed 07/16/2019