Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (75)
i4S'EGF IVF n • IMOTN0v' 192018 i i6 ARL, U Y OF tOARD MiTeklP 301.DINGDIvisloN MiTek USA, Inc. 7777 Greenback Lane Suite 109 Citrus Heights,CA,95610 Telephone 916/676-1900 Re: PL15-337_UPPER Fax 916/676-1909 POLYGON The truss drawing(s)referenced below have been prepared by MiTek USA,Inc.under my direct supervision based on the parameters provided by Pacific Lumber&Truss Co.. Pages or sheets covered by this seal: R45630218 thru R45630229 My license renewal date for the state of Oregon is June 30,2017. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. '`ce p PRppe6'' ��5 �NG I N ',9' /Q 2 t 87022PE fir' - cl\ N Aj, OREGON r15' w 'A0 AMBER �� �© A.. Hen October 12,2015 Hernandez,Marcos The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer,per ANSI/TPI 1. • Job Truss Truss Type Qty Ply POLYGON R45630218 PL15-337_UPPER F01 Floor 17 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Mon Oct 12 06:04:17 2015 Page 1 ID:SygD?CTgSFZSjSNcSIttIDzR3Xv-A0EcZ3onm?OLP7cVkKn9ahfXVrEjw5mkQI3LxLyUBYC 280 I 10-10-2 11 1-2-0 110-11-2 1 Scale=1:32.8 1.5x3 II 3x6 = 1.5x3 II 3x4= 1.5x3 I 13x4 = 3x4= 1.5x3 II 3x6= 1.5x3 II 1 2 3 4 5 6 7 8 9 10 e e ® oe T� _ o _ o e = _ • o � N / \ N t v 17 16 15 14 13 12 I 3x4 = 3x8= 3x6= 1.5x3 II 1.5x3 II 3x8= 3x4 = 12-6-2 I 11-4-2 11-11-2.1 1 18-9-12 I 11-4-2 b-7-0 0-7-0 6-3-10 Plate Offsets(X,Y)— 16:0-1-8,Edoel,17:0-1-8,Eduel LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.42 Vert(LL) -0.29 15 >767 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.79 Vert(TL) -0.46 15-16 >483 360 BCLL 0.0 Rep Stress Incr YES WB 0.66 Horz(TL) 0.07 11 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:85 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 17=822/Mechanical,11=822/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-2976/0,3-4=-2976/0,4-5=-3689/0,5-6=-3689/0,6-7=-3386/0,7-8=-2944/0,8-9=-2944/0 BOT CHORD 16-17=0/1772,15-16=0/3588,14-15=0/3386,13-14=0/3386,12-13=0/3386,11-12=0/1775 WEBS 2-17=-1913/0,2-16=0/1299,4-16=-660/0,4-15=-57/292,5-15=281/0,6-15=-62/602,9-11=1916/0,9-12=0/1262, 7-12=756/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ��0� NGINEF'YsfQsy � 87022PE N y �-0?, OREGON rt,o Q<U �O �M13ER \� �� A. HE¢�P EXPIRES:06/30/2017 October 12,2015 II _ ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII.7473 rev.10/03/2015 BEFORE USE. Mil Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek° is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing at trusses and truss systems,see ANSI/TPI1 Qualify Criteria,DSB-89 and SCSI Building Component Suite 109 Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45630219 PL15-337 UPPER F02 Floor 5 1 Job Reference(ootionall Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Mon Oct 12 08:04:19 2015 Page 1 �� ID:SygD?CTgSFZSjSNcS1ttIDzR3Xv-7PMN_Ipl Ice3eQlurlpdf6kulfOKO5vl ucYS?EyUBYA 1 2-6-0 1 1 1-4-4 11 1-2-0 1 1 2-0-0 IY77������ I 2-5-8 -_ll 1-2-0 11 2-0-8 1 1 1-44 1 Scale=1:41.3 1.5x3 II 1.5x3 I I 1.5x3 II 3x6= 1.5x3 II 3x6 FP= 1.5x3 I I 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Ltd-- o • 7 ooma_ ®® � , I_ � NQ e ee5555555,5511. 25 24 23 22 21 20 19 18 17 16 15 3x6 FP= 1.5x3 II 3x5=3x6= 1.5x3 II 3x8= 3x6= 1.5x3 II 7-10-12 14-9-8 I 6-8-12 7t3-121 1 10-11-0 1 13-7-8 114-2-81 1 19-7-0 I 23-8-4 I 6-8-12 6-7-0 3-0-4 2-8-8 6-7-0 4-9-8 4-1-4 0-7-0 0-7-0 Plate Offsets(X,Y1— 14:0-1-8,Edgel.15:0-1-8,Edgel.18:0-1-8,Edoel.f17:0-1-8,Edgel LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.29 Vert(LL) -0.06 22-24 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.39 Vert(TL) -0.10 24-25 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.30 Horz(TL) 0.01 16 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:109 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. All bearings 0-5-8 except(jt=length)15=Mechanical,25=0-4-4. (Ib)- Max Uplift All uplift 100 lb or less at joint(s)15 Max Gray All reactions 250 lb or less at joint(s)15 except 25=449(LC 14),19=877(LC 3),16=745(LC 14) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1159/0,3-4=-1159/0,4-5=-892/0,7-8=0/400,8-9=-423/83,9-10=-423/83, 10-11=0/603,11-12=0/603,12-13=0/597 BOT CHORD 24-25=0/863,23-24=0/892,22-23=0/892,21-22=0/892,20-21=0/892,19-20=-400/0, 18-19=-83/423,17-18=-83/423,16-17=-93/268,15-16=-304/44 WEBS 7-19=-590/0,2-25=-932/0,2-24=0/319,4-24=0/403,5-20=-964/0,8-19=-694/0, 10-16=-802/0,13-15=-47/329,13-16=-475/0,7-20=0/586 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 3x4 MT20 unless otherwise indicated. 3)Refer to girder(s)for truss to truss connections. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)CAUTION,Do not erect truss backwards. •<G? -Q PR QF -s .44 17 Mir - / _. -p NN �-Qj, OREGO ct�Q</ 9C c-41 , R \'\ O ' A. HERCP EXPIRES:06/30/2017 October 12,2015 4 mem NI ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1.7473 rev.10/03/2015 BEFORE USE. " Design valid for use only with Mirek®connectors.This design is based only upon parameters shown,and is for an individual building coponent,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPII Quality Criteria,DSB-89 and BCSI Building Component Safely IntormallSuite 109 on available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. CitrusuiteHeights.CA 95610 • Job Truss Truss Type Qty Ply POLYGON R45630220 PL15-337 UPPER F03 Floor 5 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Mon Oct 12 08:04:19 2015 Page 1 ID:SygD?CTgSFZSjSNcS1ttIDzR3Xv-7PMN Ip1lce3eQlurlpdf6kv2f5W0651ucYS?EyUBYA I 2-5-4 I I 1-2-0 I I 2-0-8 I 2-6-0 1 1 1-4-4 Scale=1:22.2 1.5x3 II 3x4= 1.5x3 II 3x4= 3x4 II 3x4= 1.5x3 II 1 2 3 4 5 6 7 e e Y o _ e '--N N -4011111/ o e 6 '' e , 1 Sir11 10 8 3x4= 1.5x3 I I 3x4= 3x8 = 3x4= 3-11-12 I 2-8-4 13-3-1 1 3-10-4 I 8-7-12 8-�} 12-9.0 I 2-8-4 0-7-0 0-7-0 0-1-k 4-8-0 0-1-k 3-11-12 Plate Offsets(X,V)— 12:0-1-8,Edgel,110:0-1-8,Edael LOADING(pst) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.22 Vert(LL) -0.03 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.13 Vert(TL) -0.05 9-10 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.22 Horz(TL) 0.01 9 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:58 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing:8-9. REACTIONS. (lb/size) 12=317/0-2-8,8=55/Mechanical,9=738/0-5-8 Max Uplift8=-66(LC 3) Max Gray 12=321(LC 3),8=143(LC 7),9=753(LC 8) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-565/0,3-4=-565/0,4-5=0/538,5-6=0/533 BOT CHORD 11-12=0/565,10-11=0/565,9-10=0/370 WEBS 2-12=-610/0,4-9=-841/0,6-8=-123/255,6-9=-444/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)12. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)CAUTION,Do not erect truss backwards. R pp •.0- GIN ,r�, `S . 2 �. 8 1 2PE �9r CV y N�-0j, OREGO tiQ Q<t/ 90 AMBER �1 OS A. HE0 EXPIRES:06/30/2017 October 12,2015 I ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII.7473 rev.10/03/2015 BEFORE USE. MI. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 ' Citrus Heights,CA 95610 Job • Truss Truss Type Qty Ply POLYGON R45630221 • PL15-337_UPPER F04 FLOOR 3 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Mon Oct 12 08:04:20 2015 Page 1 ID:SygD?CTgSFZSjSNcS 1 ttIDzR3Xv-bbwIC5gf3wmwGaK4PSLsCKH4a3Q97ZFA7GH?XgyU BY9 1-9-0 I I 1.6.12 I I 1-2-12 I I- 1-6-0 I I 1-2-0 I I 2-7-4 I Scale=1:21.8 1.5x3 II 3x4= 1.5x3 II 3x8= 1.5x3 II 3x4= 1.5x3 II 1 2 3 4 5 6 7 3x4= 8 e e 0 0 o e o 0 O N N o O O ,' r 1665�` 14 • 12 11 10 9 3x4= 3x5= 3x4 II 3x5= 1.5x3 II 1.5x3 II 3x4= I 5-2-8 I 12-6-12 5-2-8 7-4-4 Plate Offsets(X,Y)— 16:0-1-8,Edge1,17:0-1-8,Edgel LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.24 Vert(LL) -0.02 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.16 Vert(TL) -0.03 9-10 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.23 Horz(TL) 0.00 9 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:60 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 13=608/0-5-8,15=202/Mechanical,9=284/Mechanical Max Gray 13=621(LC 7),15=236(LC 8),9=291(LC 4) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-290/6,3-4=-290/6,6-7=-476/0 BOT CHORD 14-15=0/287,13-14=-286/18,12-13=-292/15,11-12=0/476,10-11=0/476,9-10=0/476 WEBS 4-13=-606/0,2-15=-331/0,4-14=0/426,6-12=-302/0,4-12=0/447,7-9=-510/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. ;: O GIN�,ss% �� `4. �-7 i • i � y �'Oj, OR GON `tip Q�N 'AO AMBER 1\ �SA. H - ' EXPIRES:06/30/2017 October 12,2015 t I MIMI ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII.7473 rev.10/03/2015 BEFORE USE. ��- Design valid for use only with Mirek®connectors.This design is based onlyupon parameters shown,and is for an individual building comonent,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this desip gn into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and SCSI Building Component Suite 109 Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA 95610 • Job Truss Truss Type Qty Ply POLYGON R45630222 PL15-337_UPPER F05 FLOOR 4 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Mon Oct 12 08:04:21 2015 Page 1 ID:SygD?CTgSFZSjSNcS1ttlDzR3Xv-3nU7PRrlg0vntkvHzAs5kXgBLTh3s_pKLw1Y47yUBY8 I 2-3-12 I I 1-2-0 I I 1-0-0 1 2-6-0 Scale=1:21.9 1.5x3 I I 3x4= 1.5x3 I I 3x4= 1.5x3 I I 3x4= 1.5x3 I I 1 2 3 4 5 6 7 e e e o o _ e 0 0 "II ,A/— e e e e 12 11 10 9 8 3x4= 1.5x3 I I 3x4= 3x8= 3x4= I 12-7-4 1 12-7-4 Plate Offsets(X,Y)— 12:0-1-8,Edae1,110:0-1-8,Edgel LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) Udefl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.49 Vert(LL) -0.14 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.50 Vert(TL) -0.21 9-10 >707 360 BCLL 0.0 Rep Stress lncr YES WB 0.34 Horz(TL) 0.02 8 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:56 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 12=549/Mechanical,8=549/Mechanical FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1204/0,3-4=-1204/0,4-5=-1646/0,5-6=-1646/0 BOT CHORD 11-12=0/1204,10-11=0/1204,9-10=0/1560,8-9=0/1109 WEBS 3-10=0/263,2-12=-1310/0,6-8=-1198/0,6-9=0/579,4-10=-545/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ��co \AGN 4' s,, 2 cc 8 • 2PE /91' N / 4\.1y �-0i, OREGO cIQ QW/ OS A. HEp,4 EXPIRES:06/30/2017 October 12,2015 t r ®WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. IMIv Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building coponent,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Miiek` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/T911 Quality Criteria,DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45630223 tt PL15-337_UPPER F06 Floor 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Mon Oct 12 08:04:21 2015 Page 1 ID:SygD?CTgSFZSjSNcS1ttIDzR3Xv-3nU7PRrlgDvntkvHzAs5kXgHaTnEs2FKLw1Y47yUBY8 1-6-0 1-4-0 I I 1-2-0 I I 1-1-8 Scale=1:13.6 1.5x3 II 1.5x3 II 1.5x3 II 1.5x3 11 1 2 3x4= 3 4 5 3x4= 6 _d e e e 0 a N N e e e e 3x4= 10 9 8 7 3x4= 3x4= 3x4= I 3-1-0 1 3-8-0 1 4-3-0 1 7-1-8 I 3-1-0 0-7-0 0-7-0 2-10-8 Plate Offsets(X,Y)- f8:0-1-8,Edael,f9:0-1-8,Edciel LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) Vdefl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.09 Vert(LL) -0.01 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.11 Vert(TL) -0.02 9-10 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.12 Horz(TL) 0.00 7 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:33 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 10=308/0-2-8,7=308/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-510/0,3-4=-510/0,4-5=-510/0 BOT CHORD 9-10=0/369,8-9=0/510,7-8=0/369 WEBS 2-10=-443/0,5-7=-443/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)10. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ��1c° PRQ1 `4" �5 NGi NEER s/C) -37 yN �CV �-$, OREGON tiQ4/ '�O �' ER 1'' \4 os A. HEY' EXPIRES:06/30/2017 October 12,2015 1 1 REIM ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII.7473 rev.10/03/2015 BEFORE USE. MI Design valid for use only with Mitek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Cdteda,DSB-89 and BCSI Building Component Safely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 • Job Truss Truss Type Qty Ply POLYGON R45630224 PL15-337_UPPER F07 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Mon Oct 12 08:04:22 2015 Page 1 ID:SygD?CTgSFZSjSNcS1ttlDzR3Xv-X_2VcnswbXleVuUTIMNKHIMRss7EbUiTaam6cZyUBY7 1 2-6-0 1 0.7-8 1 1 1-2-0 1 1 1-3-4 1 1-6-0 1 1 2-5-8 1 1 1-2-0 1 1 1-11-0 1 Scale=1:23.7 1.5x3 11 1.5x3 11 1.5x3 II 1.5x3 11 1 2 3 4 5 6 7 8 9 e e e e -e. a A° \ 40/,.._ e e •• o Nissit. 00000000000001— e e e o e e a U p 16 15 14 012 11 y�0�`j 3x8= 1.5x3 11 1.5x3 11 1 3-4-8 13-11-8 1 4-6-8 1 7-6-12 1 10-3-4 pa-m-4111-5-4 I 13-7-4 1 3-4-8 0-7-0 0-7-0 3-0-4 2-8-8 0-7-0 0-7-0 2-2-0 Plate Offsets(X,Y)— f7:0-1-8,Edael.18:0-1-8,Edciel,114:0-1-8,Edael,f15:0-1-8,Edgel LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.19 Vert(LL) -0.02 15-16 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.12 Vert(TL) -0.03 15-16 >999 360 BOLL 0.0 Rep Stress Incr YES WB 0.17 Horz(TL) 0.01 10 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:63 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing:13-14. REACTIONS. (lb/size) 16=298/Mechanical,13=668/0-3-8,10=219/0-2-4 Max Gray 16=318(LC 10),13=670(LC 9),10=235(LC 4) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-539/0,3-4=-539/0,4-5=-539/0,5-6=0/262,6-7=0/268,7-8=-312/0 BOT CHORD 15-16=0/547,14-15=0/539,13-14=-15/347,12-13=0/312,11-12=0/312,10-11=0/312 WEBS 2-16=-590/0,5-13=-508/0,5-14=0/328,7-13=-504/0,8-10=-350/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 3x4 MT20 unless otherwise indicated. 3)Refer to girder(s)for truss to truss connections. 4)Provide mechanical connection(by others)of truss to bearing plate at joint(s)10. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards. ��EO P R OFFS kms cNG NEER S> 870 2PE /91' N cv -y �4j.. OREGON rte Q<44 9O 'MBER 1\ Ca °S a. HES EXPIRES:06/30/2017 October 12,2015 A 1 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE M11-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not 'x aa truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTeka is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component Safely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45630225 ' PL15-337_UPPER F08 Floor 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc. Mon Oct 12 08:04:23 2015 Page 1 ID:SygD?CTgSFZSjSNcS 1 ttIDzR3Xv-?Actg7sYMr9V723f4auZpyvYnGHvKp2cpE Wf8?yUBY6 2-6-0 I 1 1-0-10 11 1-2-0 It: '1'__11-2-I Scale=1:33.2 1.5x3 II 3x6 = 1.5x3 II 3x4= 1.5x3 II 3x4= 3x4= 1.5x3 II 3x6= 1.5x3 II 1 2 3 4 5 6 7 8 9 10 ` 9 e N I I O \ O/O O\e • N 1� 16 15 14 13 12 3x4 = 3x8= 3x6= 1.5x3 II 1.5x3 I I 3x8= 3x4= 12-8-10 I 11510 1R-1-10I I 19-0-4 I 11-8-10 0-7-0 0-7-0 6-3-10 Plate Offsets(X,Y)— 16:0-1-8,Edge1.17:0-1-8,Edael LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.43 Vert(LL) -0.31 15 >738 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.80 Vert(TL) -0.48 15-16 >469 360 BCLL 0.0 Rep Stress Incr YES WB 0.67 Horz(TL) 0.07 11 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:86 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (Ib/size) 17=831/0-2-8,11=831/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-3020/0,3-4=-3020/0,4-5=-3781/0,5-6=-3781/0,6-7=-3451/0,7-8=-2988/0,8-9=-2988/0 BOT CHORD 16-17=0/1795,15-16=0/3655,14-15=0/3451,13-14=0/3451,12-13=0/3451,11-12=0/1798 WEBS 2-17=-1937/0,2-16=0/1323,4-16=-685/0,4-15=-28/296,5-15=-266/0,6-15=-69/599,9-11=-1940/0,9-12=0/1285, 7-12=-786/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)17. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. � E . PR OFes ��\; oNG(N�� sf�9 co N ycc`'oj, OR EG N tiz' 40 -PO ‘ii,/ 1°' \O Q`S A. Hc ' EXPIRES:06/30/2017 October 12,2015 4 t e.e. A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MlI.7473 rev.10/03/2015 BEFORE USE. '' Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building coponent,not a truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent bucking of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312.Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45630226 , PL15-337_UPPER F09 Floor 3 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Mon Oct 12 08:04:23 2015 Page 1 ID:SygD?CTgSFZSjSNcSIttIDzR3Xv-?Actg7sYMr9V723f4auZpyvYmGHuKp1 cpEWf8?yUBY6 2-6-0 I 1 1-0-14 11 1-2-0 1 10-11-2 1 Scale=1:33.2 1.5x3 I I 3x6 = 1.5x3 II 3x4= 1.5x3 II 3x4= 3x4= 1.5x3 II 3x6 = 1.5x3 II 1 2 3 4 5 6 7 8 9 10 e o 0cv 14444144444444411- :/ 0 _ N / - e e e 1 16 15 14 13 12 3x4 = 3x8= 3x6 = 1.5x3 II 1.5x3 I I 3x8= 3x4= 12-8-14 I 11-6-14 12-1-1q 19-0-8 I 11-6-14 0-7-0 0-7-0 I 6-3-10 Plate Offsets(X,Y)-- 16:0-1-8,Edael,17:0-1-8,Edael LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.43 Vert(LL) -0.31 15 >735 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.80 Vert(TL) -0.48 15-16 >468 360 BCLL 0.0 Rep Stress Incr YES WB 0.67 Horz(TL) 0.07 11 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:86 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 17=832/0-2-12,11=832/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-3025/0,3-4=-3025/0,4-5=-3791/0,5-6=-3791/0,6-7=-3457/0,7-8=-2992/0,8-9=-2992/0 BOT CHORD 16-17=0/1797,15-16=0/3661,14-15=0/3457,13-14=0/3457,12-13=0/3457,11-12=0/1800 WEBS 2-17=-1940/0,2-16=0/1326,4-16=-687/0,4-15=-25/297,5-15=-265/0,6-15=-69/600,9-11=-1943/0,9-12=0/1287, 7-12=-789/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)17. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. R Opp c` ' OI E6,/ ;., -.,9 1!) Lz� 87022PE 9r • NyNi< N -0i, OREG0N cP � `� � \ pQ Or) �8ER1P k9 ¢� aHE EXPIRES:06/30/2017 October 12,2015 I 1 A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. MI Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building coponent,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design imnto the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek° is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TP11 Qualify Criteria,DSB-89 and BCSI Bugding Component Suite 109 Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA 95610 • Job Truss Truss Type Qty Ply POLYGON R45630227 PL15-337_UPPER F10 Floor 5 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Mon Oct 12 08:04:24 2015 Page 1 ID:SygD?CTgSFZSjSNcS 1 ttIDzR3Xv-TM9F1 TIA78HMkCeselPoMASmygmg3JWm 1 uFDgRyU BY5 1 1-8-4 1 1-2-12 1 2-6-0 1 I 1-2-0 1 I 1-3-0 I 1-6-0 I Scale=1:22.1 1.5x3 II 3x6 = 3x5= 1.5x3 I I 3x4= 1.5x3 I I 3x4= 1.5x3 I I 1 2 3 4 5 6 7 8 + o ® or O II N � O N All,— — t ?e o e e e 14 • 12 11 10 9,' 3x4= 3x6= 3x6 = 1.5x3 II 3x4= 3x4= 1 1-11-4 I 8-6-8 1 9-1-8 1 9-8-8 1 12-8-8 I 1-11-4 6-7-4 0-7-0 0-7-0 3-0-0 Plate Offsets(X,Y)— [5:0-1-8,Edgel,[10:0-1-8,Edael LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.21 Vert(LL) -0.05 11-12 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.24 Vert(TL) -0.07 11-12 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.47 Horz(TL) 0.00 9 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:59 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 14=-381/Mechanical,13=1097/0-5-8,9=390/0-2-8 Max Uplift 14=-438(LC 4) Max Gray 13=1097(LC 1),9=390(LC 4) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=0/802,3-4=-661/0,4-5=-661/0,5-6=-799/0,6-7=-799/0 BOT CHORD 13-14=-802/0,11-12=0/799,10-11=0/799,9-10=0/497 WEBS 2-13=-588/0,2-14=0/918,3-12=0/891,3-13=-810/0,7-9=-598/0,7-10=0/393 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)9. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)CAUTION,Do not erect truss backwards. '<c\\ v.0 P R OFFS ��� , GI NE.cR �io2 r N y �4j, OREGO (1)Q<U �o �MQER '\`` OS A. H E.ck EXPIRES:06/30/2017 October 12,2015 f ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. 111, Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent bucking of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek° is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPII Quality Criteda,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 • Job Truss Truss Type Qty Ply POLYGON R45630228 PL15-337_UPPER F11 Floor 3 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Mon Oct 12 08:04:25 2015 Page 1 ID:SygD?CTgSFZSjSNcS 1 ttIDzR3Xv-xZjeFououSPDMLD2C?w1 vN_xX48wogavGY?m DuyUBY4 I 2-5-4 I I 1-2-0 I I 2-0-8 2-6-0 1-5-0 Scale=1:22.3 1.5x3 II 3x4= 1.5x3 II 3x4= 3x4 II 3x4= 1.5x3 I I 1 2 3 4 5 6 7 • Y e _ _ e • i I — 7— i N N iiiii o e Xua e ' 0 1� 11 10 3x4= 1.5x3 II 3x4= 3x8= 3x4= 3-11-12 I 2-8-4 13-3.4 I3 -104 8-7-12 84yt 12-9-12 I 2-8-4 0-7-0 0-7-0 0-4-8 4-8- 0 0-'1-8 40-8 Plate Offsets(X,Y)— 12:0-1-8,Edael,f10:0-1-8,Edael LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.22 Vert(LL) -0.03 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.13 Vert(TL) -0.05 9-10 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.22 Horz(TL) 0.01 9 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:58 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing:8-9. REACTIONS. (Ib/size) 12=317/0-2-8,8=60/0-2-12,9=739/0-5-8 Max Uplift 8=-64(LC 3) Max Gray 12=321(LC 3),8=146(LC 7),9=754(LC 8) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-565/0,3-4=-565/0,4-5=0/538,5-6=0/533 BOT CHORD 11-12=0/565,10-11=0/565,9-10=0/370 WEBS 2-12=-610/0,4-9=-841/0,6-9=452/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)12,8. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. .<�Q`,p PROFFS �c\ .-`.' FR 6j 02 87022PE 9� co tN y �Ais OREG•N rtc 4Q./~ '9O BER 1'‘ OS A. HEY" EXPIRES:06/30/2017 October 12,2015 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. N'. Design valid for use only with Wield®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek. is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and SCSI Building Component Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312.Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45630229 • PL15-337_UPPER F12 Floor 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc. Mon Oct 12 08:04:25 2015 Page 1 ID:SygD?CTgSFZSjSNcS1ttIDzR3Xv-xZjeFououSPDMLD2C?wlvN wm44_opYvGY?mDuyUBY4 2-6-0I I 1-44 I I 1-2-0 I I 1.3-4 I 1-6-0 I Scale=1:18.9 1.5x3 I I 3x4= 1.5x3 I I 3x4= 1.5x3 I I 3x4= 1.5x3 I I 1 2 3 4 5 6 7 e a - e a —o- 0 0 c;, Z . N �a O7,o e e 12�! 11 10 9e3x4= 3x6 = 1.5x3 II 3x4= 3x4= I 6-8-12 1 7-3-12 1 7-10-12 I 10-11-0 I 6-8-12 0-7-0 0-7-0 3-0-4 Plate Offsets(X,Y)— f4:0-1-8,Edael.f9:0-1-8,Edael LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.27 Vert(LL) -0.06 10-11 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.38 Vert(TL) -0.10 11-12 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.29 Horz(TL) 0.01 8 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:50 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 12=475/0-4-4,8=475/0-2-12 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1280/0,3-4=-1280/0,4-5=-1064/0,5-6=-1064/0 BOT CHORD 11-12=0/925,10-11=0/1064,9-10=0/1064,8-9=0/624 WEBS 2-12=-998/0,2-11=0/383,4-11=-22/331,6-8=-749/0,6-9=0/566 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)8. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ��Q;EO P R OFFS �,\� NGI NEFh' sfO9 • . N / SRI 7 �- OR r ©4/ 9O '.,/,/ ..\1� \ OS A. HE % EXPIRES:06/30/2017 October 12,2015 I 1 MI= Mi ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII.7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not t a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component Suite 109 Safety information available from Truss Plate Institute.218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite Heights,CA 95610 Symbols Numbering System A General Safety Notes PLATE LOCATION AND ORIENTATION 1 /4 s " Center plate on joint unless x,y 6-4-8 dimensions shown in ft-in-sixteenths Failure to Follow Could Cause Property offsets are indicated. Injury I (Drawings not to scale) Damage or Personal In g ry Mil1111Dimensions are in ft-in-sixteenths. ii� Apply plates to both sides of truss 1 2 3 1. Additional stability bracing for truss system,e.g. and fully embed teeth. diagonal or X-bracing,is always required. See BCSI. TOP CHORDS 2. Truss bracing must be designed by an engineer.For 0-/7 6"Millrinff 4 vride truss spacing,individual lateral braces themselves may require bracing,or alternative Tor p bracing should be considered. w 1.1111141* � 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. Prov his russ design o e lding 1111\66111111111111M1411 7-: C6-7 5-6 4. designee copies of r,erectiontsu tervisorr,properlyth ownerland For 4 x 2 orientation,locate BOTTOM CHORDS dl other interested parties. plates 0-na. from outside edge of truss. 8 7 6 5 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE joint and embed fully.Knots and wane at joint required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO locations are regulated by ANSI/TPI 1. connectorlates. THE LEFT. p 7. gesign assumes trusses will be suitably protected from CHORDS AND WEBS ARE IDENTIFIED BY END JOINT the environment in accord with ANSI/TPI 1. Plate location details available in MiTek 20/20 NUMBERS/LETTERS. software or upon request. 8. less otherwise noted,moisture content of lumber s 411 not exceed 19%at time of fabrication. PRODUCT CODE APPROVALS 9. ess expressly noted,this design is not applicable for PLATE SIZE u e with fire retardant,preservative treated,or green lumber. ICC-ES Reports: I i The first dimension is the plate 10. tuber is anon-structural consideration and is the 4 x 4 width measured perpendicular ESR-1311,ESR-1352,ESR 1988 r s onsibil tay of truss fabricator.General practice is to to slots.Second dimension is ER-3907,ESR-2362,ESR-1397,ESR 3282 ber for dead load deflection. the length parallel to slots. 11.P to type,size,orientation and location dimensions i icated are minimum plating requirements. LATERAL BRACING LOCATION 12.L ber used shall be of the species and size,and i II respects,equal to or better than that / Indicated by symbol shown and/or Trusses are designed for wind loads in the plane of the s cified. by text in the bracing section of the truss unless otherwise shown. 13.Top chords must be sheathed or purlins provided at output. Use T or I bracing spacing indicated on design. if indicated. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs relyon lumber values 14.Bottom chords require lateral bracing at 10 ft.spacing, g or less,if no ceiling is installed,unless otherwise noted. BEARING established by others. .../... 15.Connections not shown are the responsibility of others. Indicates location where bearings 16.Do not cut or alter truss member or plate without prior (supports) occur. Icons vary but ©2012 MiTek®All Rights Reserved approval of an engineer. reaction section indicates joint 1 ® ( number where bearings occur. 17.Install and load vertically unless indicated otherwise. f ` Min size shown is for crushing only. Eli NEI 18.Use of green or treated lumber may pose unacceptable environmental,health or performance risks.Consult with project engineer before use. Industry Standards: ANSI/TPI1: National Design Specification for Metal 19.I�eNiew all portions of this design(front,back,words Plate Connected Wood Truss Construction. gnkt pictures)before use.Reviewing pictures alone DSB-89: Design Standard for Bracing. a is'riot sufficient. BCSI: BuildingComponent SafetyInformation, mil/ 20.Design assumes manufacture in accordance with p g Guide to Good Practice for Handling, milek DNSI/TPI 1 Quality Criteria. Installing&Bracing of Metal Plate Connected Wood Trusses. MiTek Engineering Reference Sheet:MII-7473 rev. 10/03/2015