Loading...
SGN2019-00048 CITY OF TIGARD SIGN PERMIT a Permit#: SGN2019-00048 COMMUNITY DEVELOPMENT Date Issued: 06/06/2019 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Parcel: 2S103DC01100 Jurisdiction: Tigard Name of Business: Grace Point Community Church Business Address: 11075 SW GAARDE ST A Applicant/Agent: MCCORMICK, TONY Work Description: New 6-foot-tall freestanding sign. Sign face is 32 square feet. Permanent: Yes Freestanding: Yes Freeway: No Temporary: Wall: No Electronic: No Billboard: No Balloon: No Banner: No A-Board: No Sign Dimensions: 4'x 8' Total Sign Area: 32 Wall Area: Wall Face(Direction): Sign Height: 6 ft. Projection From Wall: in. Illumination: Internal Materials: Aluminum, Lexan Electrical Permit Required: Yes Building Permit Required: No Total Permit Fee: $218.00 Conditions: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. A permanent sign must be placed within 90 days from approval date or sign permit shall expire. A temporary sign shall expire 30 days from validity date. A balloon sign shall expire 10 days from validity date. Approved By: Permittee Signature: � .� , -- RECEIVED JUN 062O19 ' ` City of Tigard CITY OF TIGARD '.C134,?-;" . PLANNING/ENGINEERING 61 _ a COMMUNITY DEVELOPMENT DEPARTMENT 0:; Sign Permit Application SIGN LOCATION jj 61-44-4C REQUIRED SUBMITTAL Address: // �,.�! Gtr 61--4'4 C t�IT Suite#: Ri.RMENTS Ci state: .�"/6A F+) Dim-. Zip: 7�,2T �1/ 2 copies of elevations on 8'/z"x 11" City/state: '.191 i9Vid r 64)/411 or 11"x 17"pages(Wall sign Tenant or business: Ar elevations must include dimensions of sign andwall faow the Property owner name: /1�/ r1 ST e�y l�'-r/ i/ f'�fl�y5 location of sign on the vvalL Address: /1 t tJ . 4(� /1,4,(. 6t. ,J l , Freestanding sign elevations must el. i drawn to scale.) ��� City/state: !t(t DA-- lip: 7dy ...!!! 2 copies of site/plot plan,drawn Phone: Email: to scale,on 81/2"x 11"or 11"x 17" 1t3 L . , '�� C� /ageS(nat required for�vali signs) Slgn contractor: JodL ' � ist or diagram of all existing sign Address: 152;45 �' fe-tv 7.,/2•172/ - g / mensions and square footage City/state: -- lb/41-4) O/L- Zip: l�+�' T l pplication Fee Phone: 97/ -D52 -i51d Email: /t1I -ij3-e/1.if-ye?c i Al .L'/iLk NOTES: CCB License#: 1 Expiration date: g ��yt �,n C . freestanding signs over 6 ft.in height Contact person: >"i✓t J �// 1 t and walls signs of which any element weighs 20 lbs.or more require a building permit for construction. SIGN DATA(Complete all items in this section) if any clement of a wall sign weighs 70 lbs.or more,plans must be prepared TYPE (Check all that apply) by a structural engineer. New sign i Freestanding ❑ Electrical • Building permits require 2 sets of ❑ Alteration to construction drawings and,if sign is 0 Freeway 1:1 Wall 't'g existing,sign ❑ Roof 0 Otherfreestanding 2 copies of site/plot plan and 2 sets of engineering must be Sign#: submitted with building permit � _„,.Y� .® application. Sign dimensions:�� -7 (h) x (w) = U sq.ft. sign area sign: ,/lam sq.ft.+ gsign 5 Fr R R S1 4FF IJS ONi.?5 I Newsi s Existing area .t�J ,,,,ft...--ffotal 5Z j /� !Total sign area: sq.ft./___l__building face sq.ft._ %of bldg face Cast. leo,: !9� &160171b1 Height to top of si :_ ft.Projection from wall: in. ltdatcd Case N (s): Materials: li l tM l d ilVM_.t 1—l:f i ` 1 et. D Application acct ted : . Is the sign under 20 lbs.? 0 Yes No _ gy Date: 9 (Building Permit required if over 20lin) Application detei mined complete: Direction wall faces(circle one): N S 00 NE NW SE SW {� By: . I Will the sign have illumination? Yes 0 Na " Date If yes,what type: Internal 0 External 1;\Commumry Deveioymentliend use Appikeior6102 r°n°s anti J Femvie tts14UseAppl•t Par um/am City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwu:tigard or.gov • 503-718-2421 • Page 1 of 2 APPLICANTS NOTE: Person specified as"Applicant"shall be designated"Permittee"and shall provide financial assurance for work. \Vhcn the owner and the applicant axe different people,the applicant must he the purchaser of record or a lessee in possession with written authorization fmm the owner or an agent of the owner. The owner(s)must sign this application in the space provided on the hack of this form or submit a written authorization with this application. THE APPLICANT(S)SHALL CERTIFY THAT: • If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. • All of the above statements and the statements in the plot plan,attachments,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denying the application. I hereby ackn.w)edge that I have read this application,that the information given is correct,that I am the owner or autho ' d ent of the owner,and that plans submitted are in compliance with the City of Tigard. SI .NA S of -.ch owner o the subject property re• ired, r . et.,. I21 66 � j1(- // 30 Applicant's si• ature Print nam- Date 7Z- 9-- - 4---_/"."'''''---. ----S ItS,PA....a: S 'ner s signature Print name Date Owner's signature Print name Date Tmm SIGN PERMIT APPLICATION City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 2 of 2 Manufacture & Install New: Internally Illuminated DS Monument Cabinet Sign QTY: 1SPECIFICATIONS CABINET LIGHTING '6,iaeeR ,..,:ait.H..) t. . ., ... WHITE LED • FACES 3116"LEXAN VINYL FIRST SURFACE DEPTH 14" RECEIVEDCOLORS SEE COLOR KEY SCOPE OF WORK: JUN 0 6 2019 MANUFACTURE&INSTALL NEW DOUBLE SIDED,ILLUMINATED CABINET 8,4111 MONUMENT SIGN CITY OF TIGARD 11 PLANNING/ENGINEERING COLOR KEY PAINT _ WHITE III PAINT BLACK i . VINYL FULL COLOR DIGITAL PRINT -- i C1 OF T'IGARD Approitials:ved by PlaC mg Date N /�. 4 '1/ate 7;i??). . o In COMMUNITY CHURCH PROPOSED SIGNAGE 11,..*‘A,,,,:',,_!'•:,t 4*Ifi....Nr.i'.,.,7-;k:19,•; . .,• , ,,-,* .-. '" . 40 •• f- I ft', . ' . Iirklfik''tqkx.-..%rit'' Pt;,X" 442.._#4.1!-, -44.-,' ' le' %--%.4 '' '14. It.,.- -.114v,,,,,... .,,i:4:--. ..;-. .:. ,..,...1.4„,e, fest t '''''. - ' ,,,W,,,,,,,,,,,o,, COMMUNITY CHURCH t • N ,.. t e , k'8..e.4d..,if.. *. 'V Option 1 3 51 SQUARE FEET CUSTOMER APPROVAL: sah I�neo-coo- PROJECT:Grace Point Church_ ACCT.MGR: Rob lt.eiZii2 This is an o ginal unpublished drawing created for � y P CONCEPT A R T Meyer Sign Company's customer and the project planned Attention:�y�� _arc\ pI0 II 20-8 00 ADDRESS:11 D76.SW GaaLde..Vit. SHOP MGR: Rich Hopkins INITIALS DATE for the specific needs of Meyer sign customers. Colors shown on this artwork are for representational purposes only. �/ � These drawings are not to be shown outside your An inkjet printer,printing on copier or computer monitor display NRENDER#: organization eyeSiynor used,copied,reproduced,or exhibited phone:: ® ��®-��®® Tigard,OR 97224 R 1 LANDLORD APPROVAL: cannot exactly duplicate the true color of the materials used ° F O R REFERENCE O N LY many way unless authorized in writing by an officer of in the actual sign making process.fax:: S® G�® AO74 DESIGNER: Sam Dantone D A T E 10/2412015 Meyer Sign Company of Oregon. 9 9 INITIALS DATE ; SITE PLAN � ' -- t 1107 e S e ' 5 SW Gaard t. ,., ,' `= T r OR 97224 y � P ( ,... .: * -.1, , --1....i , Rte.: ` . LOT BOUNDARY 3 4.1' r� ' i ' p,. .: Description of work: n ' ; : - II I d +k . t n ern u . 411 tt * monument s ane area <'�x mon met ign in planter r '* 'It.(*.'"'''.--/'''it t . k � ' � , s. Lo.. property. ;, '''''!„,14-, � } � . � .s, at Southern end ofr Y • '�'_.• 4 "'°°1 lt�,i i?A ve €Z�;'p g, `# x 1.' ,,,,,,,,,,,,,,...i, 'g S Contractor• .,....010 +�,.. w: lid' ," ,� , .i *, � -"' > �"' , �y . ,. , -$ fOrg n Meyer Sign o e o ,.if . 15205 SW 74th Ave ici, g +` . .` - 'do 4: (503) 620-8200 24i/P..,,,Iiii.-ii. v ... ,.. ill P ,.., ,t..... a Contact. Tony McCormick • n .-.., ,E,,, ,1 ' ' * Business to receive sign: 44, ."� s s• 3 g h* ' ' * - '' ,. �. . a ,.. race oinGur . .fi Tigard, OR 97224 '44 1:*'' 4 -v't...."--0,;:41`l':' , '48i1:7,411:F ° F ,` 111111" i ),,,,,:-.41„.''t - Scale: 1 16 = 3' _ .A Mtli � T [/''lam j�+y�{y�/}�y-�+ , +' . "Ur 'S St North T I et.'r., : '. -- 41°. a ... Nttv l'i: . . ..., lit 1. Sign'. • 31,,r Alti M' OF OREGON ,,:.. - wb rte. a SIGN 1 LOCATION 35' 15205 SW 74th Ave Tigard, OR 97224 (503) 620-8200 _ — permits@meyersignco.com °oc e µ art . . Scope of work is for the design of the sign pole and the foundation. ,`53 PRace See following pages for structural notes. G ) N F /O� 72525PE lI LOADING: WIND: ASCE7-10 120 MPH,EXP B MAXIMUM HEIGHT(h)= 6.00 ft ,-?. o ,, (3 second gust) GUST FACTOR(G)= 0.85 i l' K1 = 0.00 (ASCE 7-10 Figure 26.8-1) F=qz*G*Cr0.6:(allowable) lF ; o s ' p�' K2= 1.00 (ASCE 7-10 Figure 26.8-1) Kz qz F(psf) h S`�%SEPH MPs K3= 1.00 (ASCE 7-10 Figure 26.8-1) 0.57 17.86 = 13.0 0-6 ft Kzt= 1.00 (ASCE Eqn. 26.8-1) EXPIRES: 12-31-2020 Kd= 0.85 (ASCE 7-10 Table 26.6-1) u U Cf= 1.43 (ASCE 7-10 Figure 29.4-1) s= 6.00 ft s/h= 1.00 1 r - B= 8.50 ft B/s= 1.42 3" DIA. 0.2*B= 1.70 ft(code offset,for wind load) offset= 0.00 ft(horizontal cabinet offset) w/5*H SCH. 40 FORCES: o PIPE Height to Height to Area Wind load Force Height to Moment i Width bottom(ft) top(ft) (sq.ft.) (psf) (lbs) center(ft) (ft-Ib) c9 1 r 8.00 2.00 6.00 32.0 13.0 417 4.30 1793 8.50 0.00 2.00 17.0 13.0 221 1.30 287 0.00 0.0 13.0 0 0.30 0 - -, J L 0.00 0.0 13.0 0 0.30 0 0.00 0.0 13.0 0 0.30 0 0.00 0.0 13.0 0 0.30 0 0.00 0.0 13.0 0 0.30 0 CONCRETE E= 638 E= 2080 FOOTING SIGN POLE: (Single Pole) Try a 3"SCH40 sign pole 2'-0" z= 2.19 in3 T= 1085 ft-lb =638*(1.T+0') IDIA. Fy= 35000 psi Tc= 3601 ft-lb SIG\ L U A T I O Mx= 2080 ft-lb 0.30>0.2 comb.stresses req. My= 0 ft-lb Comb.= 0.635 < 1.00 OK NTS Mc= 3825 ft-lb =35000*2.19/12/1.67 2080 <3825 OK lUse a PIPE 3"SCH40 sign pole I ____ mil FOUNDATION CHECK: IA Mnet= 0.96 k-ft =(2080)/1000-1.12ft-k 1/2" DIA. BOLT P= 0.638 k Applied lateral force p h(effective)= 1.50 ft distance from ground surface to P q= 300 psf/ft allowable soil-brg., q=2(150)=300* I_i Footing shape: Circular _ *Allowable w/1/2"movement at groundline b= 2 ft diameter POLE POCKET CONNECTION 2 ft diameter b'= 2.00 ft diameter d(estimated)= 3.50 ft Estimated embedment Unconstrained Condition volume of concrete= 0.4 yd S_1 = 350 psf q*d_est/3 footing wt= 1.6 k A= 2.13 ft 2.34*P*1000/(S_1*b) sign wt= 0.50 k d= 3.22 ft A/2*(1+(1+4.36*h/A)^.5) Total wt(DL)= 2.15 k 3.22 <3.5'OK eccentricity of load to reaction(e)= 0.52 ft=1.12/2.15 maximum resistive moment available based on soil bearing,Mes.= 1.12 ft-k Use 2'-0"diameter x 3'-6"deep 3,000 psi concrete footing(designed for 2,500psi) 9570 SW Barbur BlvdProject Name Grace Point Community Church Monument Sign Project# 190500 Suite One Hundred ES Portland,OR 97219 laLocation 11075 SW Gaarde Street, Tigard, Oregon Client Meyer Sign Company of Oregon MILLER - - - - -- Phone 503.246.1250 I CONSULTING Fax 503.246.1395 CJM L P J 4/29/19 1 of 3 www.miller-se.com By Ck'd Date- Page ENGINEERS GENERAL THE CONTRACTOR IS RESPONSIBLE FOR VERIFICATION AND CORRELATION OF ALL ITEMS AND WORK NECESSARY FOR COMPLETION OF THE PROJECT AS INDICATED BY THE CONTRACT DOCUMENTS. SHOULD ANY QUESTION ARISE REGARDING THE CONTRACT DOCUMENTS OR SITE CONDITIONS, THE CONTRACTOR SHALL REQUEST INTERPRETATION AND CLARIFICATION FROM THE ENGINEER BEFORE BEGINNING THE PROJECT. THE ABSENCE OF SUCH REQUEST SHALL SIGNIFY THAT THE CONTRACTOR HAS REVIEWED AND FAMILIARIZED HIMSELF WITH ALL ASPECTS OF THE PROJECT AND HAS COMPLETE COMPREHENSION THEREOF. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONFORMANCE TO ALL SAFETY REGULATIONS DURING CONSTRUCTION. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. UNLESS OTHERWISE SPECIFICALLY NOTED, THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION OR CONSTRUCTION LOADS. ONLY THE CONTRACTOR SHALL PROVIDE ALL METHODS, DIRECTION AND RELATED EQUIPMENT NECESSARY TO PROTECT THE STRUCTURE, WORKMEN AND OTHER PERSONS AND PROPERTY DURING CONSTRUCTION. THE CONTRACTOR SHALL, AT HIS OWN EXPENSE, ENGAGE PROPERLY QUALIFIED PERSONS TO DETERMINE WHERE AND HOW TEMPORARY PRECAUTIONARY MEASURES SHALL BE USED AND INSPECT SAME IN THE FIELD.ANY MATERIAL NOT AS SPECIFIED OR IMPROPER MATERIAL INSTALLATION OR WORKMANSHIP SHALL BE REMOVED AND REPLACED WITH SPECIFIED MATERIAL IN A WORKMANLIKE MANNER AT THE CONTRACTOR'S EXPENSE. THESE PLANS, SPECIFICATIONS, ENGINEERING AND DESIGN WORK ARE INTENDED SOLELY FOR THE PROJECT SPECIFIED HEREIN. MILLER CONSULTING ENGINEERS DISCLAIMS ALL LIABILITY IF THESE PLANS AND SPECIFICATIONS OR THE DESIGN, ADVICE AND INSTRUCTIONS ATTENDANT THERETO ARE USED ON ANY PROJECT OR AT ANY LOCATION OTHER THAN THE PROJECT AND LOCATION SPECIFIED HEREIN. OBSERVATION VISITS TO THE JOB SITE AND SPECIAL INSPECTIONS ARE NOT PART OF THE STRUCTURAL ENGINEER'S RESPONSIBILITY UNLESS THE CONTRACT DOCUMENTS SPECIFY OTHERWISE. NON STRUCTURAL PORTIONS OF PROJECT, INCLUDING BUT NOT LIMITED TO PLUMBING, FIRE PROTECTION, LAND USE, SITE PLANNING, EROSION CONTROL, ELECTRICAL, MECHANICAL, FLASHING AND WATER-PROOFING ARE BEYOND THE SCOPE OF THESE DRAWINGS AND ARE PROVIDED BY OTHERS. EXISTING STRUCTURAL ELEMENTS ARE DESIGNED BY OTHERS. CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO FABRICATION OR INSTALLATION. ENGINEER OF RECORD FOR THE PROJECT IS TO BE NOTIFIED IF CONDITIONS DIFFER FROM WHAT IS SHOWN ON THE DRAWINGS. BUILDING CODE ALL PHASES OF THE WORK SHALL CONFORM TO THE 2014 OREGON STRUCTURAL SPECIALTY CODE, BASED ON THE 2012 INTERNATIONAL BUILDING CODE, INCLUDING ALL REFERENCE STANDARDS, UNLESS NOTED OTHERWISE. ,`(cS),D PRk4- 72525PE rI 440/7fe l<-8✓sSEPH MP`\�.P EXPIRES: 12-31-2020 9570 SW Barbur Blvd Project Name Grace Point Community Church Monument Sign Project# 190500 Suite One Hundred as Portland,OR 97219 11075 SW Gaarde Street,Tigard, Oregon Location Meyer Sign Company of Oregon Client MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 CJM LKS- 4/29/19 2 of 3 www.miller-se.com By -- _ Ck'd Date _ _- Page ENGINEERS i (c.ED PROFe DESIGN LOADS ` THE FOLLOWING ARE THE DESIGN REQUIREMENTS: 4„`'GINFF • STRUCTURAL DESIGN CRITERIA 72525PE P ri RISK CATEGORY II ►, -��, , WIND DESIGN DATA ,� oa BASIC WIND SPEED(3 SEC GUST) 120 MPH Fs / 0 MP�a� EXPOSURE B EXPIRES: 12-31-2020 FOOTINGS FOUNDATION CRITERIA CONTRACTOR SHALL VERIFY SOIL CONDITIONS AT THE FOOTINGS AND MAKE ANY NECESSARY CORRECTIONS TO PLACE THEM ON FIRM NATIVE SOIL OR STRUCTURAL FILL COMPACTED TO 95% OF MAXIMUM DENSITY AT OPTIMUM MOISTURE CONTENT PER AMERICAN SOCIETY FOR TESTING AND MATERIALS, ASTM D698 (STANDARD PROCTOR), OR ASTM D1557 (MODIFIED PROCTOR). THE COMPACTION SHALL BE VERIFIED BY A QUALIFIED INSPECTOR APPROVED BY THE BUILDING OFFICIAL. COMPACTED STRUCTURAL FILL FOR DEPTHS GREATER THAN 12 INCHES SHALL COMPLY WITH PROVISIONS OF AN APPROVED GEOTECHNICAL REPORT. ASSUMED SOIL BEARING PRESSURE 1500 POUNDS PER SQUARE FOOT(PSF). CONCRETE CONCRETE MIXING, PLACING AND CURING OF CONCRETE SHALL BE IN ACCORDANCE WITH THE AMERICAN CONCRETE INSTITUTE, ACI 318 AND IBC CHAPTER 19. CONCRETE SHALL BE 2500 POUNDS PER SQUARE INCH (PSI) MINIMUM AT 28 DAYS. STRUCTURAL STEEL STRUCTURAL STEEL ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE ASTM A992 FOR W-SECTIONS AND ASTM A36 FOR ALL OTHER SECTIONS, PLATES AND BARS.ALL RECTANGULAR HSS SECTIONS SHALL BE ASTM A500, GRADE B, FY=46000 PSI AND ALL ROUND HSS SECTIONS SHALL BE ASTM A500, GRADE B, FY = 42000 PSI. ALL STRUCTURAL STEEL PIPE SHALL BE ASTM A53, GRADE B, TYPE E OR S, FY= 35000 PSI. ALL STEEL IN CONTACT WITH ALUMINUM TO BE STAINLESS OR HAVE A PROTECTIVE BARRIER TO PREVENT CORROSION. UNLESS NOTED OTHERWISE, ALL BOLTS TO BE ASTM A307 AND ALL ANCHOR RODS TO BE ASTM F1554 GRADE 36, WITH MATCHING NUTS. ALL FASTENERS IN CONTACT WITH ALUMINUM TO BE TYPE 304 STAINLESS STEEL WITH MATCHING NUTS OR HAVE A PROTECTIVE BARRIER TO PREVENT CORROSION. NUTS SHALL BE TIGHTENED TO A SNUG TIGHT CONDITION PER RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS (RCSC) SPECIFICATION FOR STRUCTURAL JOINTS, SECTION 8.1. ALL STRUCTURAL STEEL SHALL HAVE ONE COAT OF PRIMER, EXCEPT SURFACES TO BE EMBEDDED IN CONCRETE OR MASONRY. EMBEDDED SURFACES SHALL BE FREE OF CONTAMINANTS. ALL ZINC (GALV.) COATINGS ON IRON AND STEEL PRODUCTS SHALL CONFORM TO ASTM A123. REPAIRS OF GALVANIZED COATINGS ARE TO CONFORM TO ASTM A780. ALL EXPOSED STRUCTURAL STEEL TO HAVE ONE FINISH COAT OF RUST INHIBITING PAINT, COLOR BY OWNER. ALL WELDING SHALL CONFORM TO AMERICAN WELDING SOCIETY (AWS) D1.1 USING E70XX ELECTRODES. WELD LENGTHS SHOWN ARE EFFECTIVE AS SPECIFIED PER THE SPECIFICATIONS OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC). WELDING SHALL BE PERFORMED BY AWS CERTIFIED WELDERS FOR WELD TYPES SPECIFIED. WHERE WELD LENGTHS ARE NOT SHOWN, THE WELD SHALL BE FULL LENGTH OF MEMBERS BEING JOINED. ALL BUTT WELDS SHALL BE FULL PENETRATION WELDS UNLESS NOTED OTHERWISE ON STRUCTURAL DRAWINGS.ALL WELDS SHALL RECEIVE THE SAME FINISH COAT AS THE MEMBER BEING WELDED. 9570 SW Barbur Blvd Project Name Grace Point Community Church Monument Sign Project# 190500 Suite One Hundred Art Portland,OR 97219 11075 SW Gaarde Street,Tigard, Oregon Location Client Meyer Sign Company of Oregon MILLER - -- _ _ - Phone 503.246.1250 CONSULTING Fax 503.246.1395 CJM L p:s4/29/19 3 of 3 www.miller-se.com By — Ck'd Date — Page ENGINEERS