Loading...
Report (53) /11151-94/4" 002tit 1670 Pm Saris oYhj 4.. 0E5) PRo" 4 ,cc ,‘G I Nitt, CT ENGINEERING CI4 di1 N C 4,4i 180 Nickerson St. f ` Suite 302 �4REG'�k Seattle,WA 98109 _ 22.,,gy.pp < (206)285-4512(V) (tS T. 206 285-0618(F) 08/28/2019 asolomonCctengineering.com BULLETIN Date: September 5, 2019 Number:CT-69 Project#: 15238 Project Name: River Terrace SF Attached: None Subject: Lot 113 (Plan 3410B DLSG)—Header for Garage Wall Electrical Panel Drawings Affected: Description/Action: This bulletin provides response to RFI's, design clarifications and/or variation requests for the `River Terrace SF' project located in Tigard, Oregon. Based on our review of the plans&the information &construction photos provided by Polygon, the existing two cripple studs located under the beam and header should be face nailed to the adjacent king stud using (2) rows 10d @ 16" O.C. Additionally, one additional cripple stud should be face nailed to the single cripple stud located on the opposite side of the electrical panel (mid-span of the header) using (2) rows 10d @ 16" O.C.. CALL WITH ANY QUESTI©NS Issued by: Yashar E, Zafari Date: Sept. 5,2019 Distribution: Contact Information: Frank Sandoval Polygon Northwest Company Chris Roberts Polygon Northwest Company Rob Howser Polygon Northwest Company David Burnett Milbrandt Architects R:115238 River Terrace SF\Bulletins\15238_2019.09.05 CT69_Lot 113(Plan 34106 DLSG)-Header for Garage Wall Electrical Panel.doc Structural Engineers