Report (52) 1670`1 5"") 61,445., 54. 0001)2/1151.20161- 0-o PRC' 4 '• . CT ENGINEERING � '; 60 tig ' 180 Nickerson St. INC Suite 302 S REG ri N Seattle,WA 98109 ' 22,,91<<cc2 (206)285-4512(V) S T G (206)285-0618(F) 08/27/2019 asolomon@ctengineering.com BULLETIN Date: August 27, 2019 Number: CT-67 Project#: 15238 Project Name: River Terrace SF Attached: None Subject: Lot 217 (Plan 3410A)—Notched LVL Beam Drawings Affected: A7 Description/Action: This bulletin provides response to RFI's, design clarifications and/or variation requests for the 'River Terrace SF' project located in Tigard, Oregon. Based on our review of the plans &the information &construction photos provided by Polygon regarding the notched 1-3/4" x 14" LVL. A 4" x 8" header should be installed above the doorway where the notched LVL is located. Issued by: Yashar E.Zafari Date: Aug. 27, 2019 Distribution: Contact Information: Frank Sandoval Polygon Northwest Company Chris Roberts Polygon Northwest Company David Burnett Milbrandt Architects R:\15238 River Terrace SF\Bulletins\15238_2019.08.27_CT67_Lot 217(Plan 3410A)-Notched LVL Beam.doc Structural Engineers 05) PRO, 1 *; 60 CT ENGINEERING W /16 ' 180 Ni!...1ckerson St. INC ' Suite 302 4V j�REGoN . Seattle,WA 98109 c5 �C�- 1 `r (206)285-4512(V) 2 *ZFS T T. 'G� (206)285-0618(F) 08/21/2019 asolomon@ctengineering.com BULLETIN Date: August 21,2019 Number: CT-64 Project#: 15238 Project Name: River Terrace SF Attached: None Subject: Lot 217 (Plan 3410A)—Header for Garage Wall Electrical Panel Drawings Affected: Description/Action: This bulletin provides response to RFI's, design clarifications and/or variation requests for the 'River Terrace SF' project located in Tigard, Oregon. Based on our review of the plans &the information &construction photos provided by Polygon, the GLB 3.5" x 9.5" header&supporting cripple studs for the garage wall electrical panel are acceptable for the given loading condition. No change is required. Issued by: Yashar E. Zafari Date: Aug. 21, 2019 Distribution: Contact Information: Frank Sandoval Polygon North Company Chris Roberts Polygon Noral .Company David Burnett Milbrandt Arc -ts R:\15238 River Terrace SF\Bulletins\15238_2019.08.21_CT64_Lot 217(Plan 3410A)-Header for Garage Wall Electrical Panel.doc Structural Engineers ��0 PRO' GINF ' CT ENGINEERING 60 T, to 180 Nickerson St. Suite 302 % +REGO 9& Seattle,WA 98109 „0, - 22,1 �cs (206)285-4512(V) 4 eS T. GRA (206)285-0618(F) 08/21/2019 asolomon@ctengineering.com BULLETIN t� Date: August 21, 2019 Number: CT-65 Project#: 15238 Project Name: River Terrace SF Attached: None Subject: Lot 217 (Plan 3410A)—Drilled Holes in LVL Beam Drawings Affected: Description/Action: This bulletin provides response to RFI's, design clarifications and/or variation requests for the 'River Terrace SF' project located in Tigard, Oregon. Based on our review of the plans &the information & construction photos provided by Polygon regarding the 1-3/4" x 14" LVL beam with five 1" diameter electrical holes drilled through. A Simpson MSTA24 strap should be attached along the bottom of the beam, where the drilled holes are located. CALL WITH ANY QUESTIONS Issued by: Yashar E.Zafari Date: Aug. 21, 2019 Distribution: Contact Information: Frank Sandoval Polygon Northwest Company Chris Roberts Polygon Northwest Company David Burnett Milbrandt Architects R:\15238 River Terrace SF\Bulletins\15238_2019.08.21_CT65_Lot 217(Plan 3410A)-Drilled Holes in LVL Beam.doc Structural Engineers i