Report (52) 1670`1 5"") 61,445., 54.
0001)2/1151.20161- 0-o PRC' 4
'• .
CT ENGINEERING � '; 60 tig
'
180 Nickerson St.
INC Suite 302
S REG ri N Seattle,WA 98109
' 22,,91<<cc2 (206)285-4512(V)
S T G (206)285-0618(F)
08/27/2019 asolomon@ctengineering.com
BULLETIN
Date: August 27, 2019 Number: CT-67 Project#: 15238
Project Name: River Terrace SF Attached: None
Subject: Lot 217 (Plan 3410A)—Notched LVL Beam
Drawings Affected: A7
Description/Action:
This bulletin provides response to RFI's, design clarifications and/or variation requests for the 'River
Terrace SF' project located in Tigard, Oregon.
Based on our review of the plans &the information &construction photos provided by Polygon
regarding the notched 1-3/4" x 14" LVL. A 4" x 8" header should be installed above the doorway
where the notched LVL is located.
Issued by: Yashar E.Zafari Date: Aug. 27, 2019
Distribution:
Contact Information:
Frank Sandoval Polygon Northwest Company
Chris Roberts Polygon Northwest Company
David Burnett Milbrandt Architects
R:\15238 River Terrace SF\Bulletins\15238_2019.08.27_CT67_Lot 217(Plan 3410A)-Notched LVL Beam.doc
Structural Engineers
05) PRO, 1
*; 60
CT ENGINEERING W /16 ' 180 Ni!...1ckerson St.
INC '
Suite 302
4V j�REGoN . Seattle,WA 98109
c5 �C�-
1 `r (206)285-4512(V)
2
*ZFS T T. 'G� (206)285-0618(F)
08/21/2019 asolomon@ctengineering.com
BULLETIN
Date: August 21,2019 Number: CT-64 Project#: 15238
Project Name: River Terrace SF Attached: None
Subject: Lot 217 (Plan 3410A)—Header for Garage Wall Electrical Panel
Drawings Affected:
Description/Action:
This bulletin provides response to RFI's, design clarifications and/or variation requests for the 'River
Terrace SF' project located in Tigard, Oregon.
Based on our review of the plans &the information &construction photos provided by Polygon, the
GLB 3.5" x 9.5" header&supporting cripple studs for the garage wall electrical panel are acceptable
for the given loading condition. No change is required.
Issued by: Yashar E. Zafari Date: Aug. 21, 2019
Distribution:
Contact Information:
Frank Sandoval Polygon North Company
Chris Roberts Polygon Noral .Company
David Burnett Milbrandt Arc -ts
R:\15238 River Terrace SF\Bulletins\15238_2019.08.21_CT64_Lot 217(Plan 3410A)-Header for Garage Wall Electrical Panel.doc
Structural Engineers
��0 PRO'
GINF '
CT ENGINEERING 60 T, to 180 Nickerson St.
Suite 302
% +REGO 9& Seattle,WA 98109
„0, - 22,1 �cs (206)285-4512(V)
4 eS T. GRA (206)285-0618(F)
08/21/2019 asolomon@ctengineering.com
BULLETIN t�
Date: August 21, 2019 Number: CT-65 Project#: 15238
Project Name: River Terrace SF Attached: None
Subject: Lot 217 (Plan 3410A)—Drilled Holes in LVL Beam
Drawings Affected:
Description/Action:
This bulletin provides response to RFI's, design clarifications and/or variation requests for the 'River
Terrace SF' project located in Tigard, Oregon.
Based on our review of the plans &the information & construction photos provided by Polygon
regarding the 1-3/4" x 14" LVL beam with five 1" diameter electrical holes drilled through. A Simpson
MSTA24 strap should be attached along the bottom of the beam, where the drilled holes are
located.
CALL WITH ANY QUESTIONS
Issued by: Yashar E.Zafari Date: Aug. 21, 2019
Distribution:
Contact Information:
Frank Sandoval Polygon Northwest Company
Chris Roberts Polygon Northwest Company
David Burnett Milbrandt Architects
R:\15238 River Terrace SF\Bulletins\15238_2019.08.21_CT65_Lot 217(Plan 3410A)-Drilled Holes in LVL Beam.doc
Structural Engineers