Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit (43)
CITY OF TIGARD MASTER PERMIT = COMMUNITY DEVELOPMENT Permit#: MST2019-00363 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 09/11/2019 7 f i ;�IF.l? Parcel: 2S106DA04800 Jurisdiction: Tigard Site address: 16854 SW FRIENDLY LN Subdivision: RIVER TERRACE EAST Lot: 48 Project: Ho Project Description: Solar photovoltaic system. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $15,750.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF RainStorm Sewer: 0 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: Y Other Description: Roof top PV system 7.875 kW Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: HO,SHIHCHUN AURIC SOLAR LLC Required Items and Reports(Conditions) a TSAU,YUANFANG------ -- ft530 SWT11AtATffl1= RV CK515 R15 16854 SW FRIENDLY LN TUALATIN,OR 97062 BEAVERTON,OR 97007 PHONE: 573-489-2079 PHONE: 503-716-3055 FAX: Total Fees: $368.19 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification itri. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You m •• -'•a copy• .•- -s or direct questions to OUNC by calling 54,4 .1987 or .800.332.2344. ��� Issued By: /lig_ _-- - _ ••'tee Signature: i� r C., 9.4175 by 7:00 a.m.for the next available inspectio e. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. -Bluldina Permit Application Residential Fi FOR OFFU F l'SF O\1.1 City of Tigard 4 ReceivedY: 7 /r1 _ j�--c ,3 ,111 4 �- - i tv i. Date/BY: /t�a1'tylRvl'7 13125 SW Hall Blvd.,Tigard,OR 97223 a Phone: 503.718.2439 Fax: 503.598.19G61t I PlDaa Review '0 Other Permit: TIG \F:r) Inspection Line: 503.639.4175 Date Ready/By: r / �, El See Page 2 for Internet: www.tigard-or.gov Buil.-,-,tri,2 L i;%f.J:Ur Notitie,,„� /, „>, f/ � I supplemental Information nt t M -,»r,i r20 ;1 kA.;; :757 10 t 11:J ❑New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ®Other:PV Solar equipment,materials,labor,overhead,and the profit for the ormir i€ t ® work indicated on this application.AgrallICtar o t' . ❑ 1-and 2-famil y dwellin Valuation: $15,750 g ❑Commercial/industrial ❑Accessory building 0 Multi-family Number of bedrooms: ❑Master builder ®Other: Solar PV Number of bathrooms: '571- ; : ;i ® : t t , t t t ri NAM Total number of floors: Job site address:16854 SW Friendly Lane New dwelling area: square feet City/State/ZIP:Beaverton,OR 97007 Garage/carport area: square feet Suite/bldg./apt.no.: I Project name:177776 Ho Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet Ira 1 IT, A "'t 1 ' it l Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no equipment,materials,labor,overhead,and the profit for the y_ t t t ' ah work indicated on this application.P ...,'; 7.875 kW Solar PV Array to be Roof Mounted Valuation: $ Existing building area: square feet New building area: square feet per. ! ® .9 i.... ,... ,,.,.i ..a ,.dr'' s t firilk el Number of stories: Name:Schichun Ho Type of construction: Address:16854 SW Friendly Lane Occupancy groups: City/State/ZIP:Beaverton,OR 97007 Existing: Phone:(573)489-2079 Fax( ) New: Business name:Auric Solar LLC Structural plan review fee(or deposit): Contact name:Mitchell Hampton FLS plan review fee(if applicable): Address:9530 SW Tualatin-Sherwood Rd City/State/ZIP:Tualatin,OR 97062 Total fees due upon application: s „( )_ r Am utat�. E-mail:rnitchelLhampton@auricenergy.com PHOT0V ' AICSOLAR E 'STM S* MINERVIIiir t' c • ,3 I„promoCommercial and residential prescriptive installation of roof-top mounted Photovoltaic Solar Panel System. Business name:Auric Solar LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:9530 SW Tualatin-Sherwood Rd Solar Installation Specialty Code checklist. City/State/ZIP:Tualatin,OR 97062 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(971)803-1803 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lie.:212831 Total fee due upon application: $201.60 Authorized signature:7112 � ��N of y� This permit application expires if a permit is not obtained 7/7 � within 180 days after it has been accepted as complete. Print name:Mitchell Hampton Date:9/09/2019 *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) f , Bliirdin2 Permit Application Checklist One- and Two-Family Dwelling Fou oFricl: t su: oyi,v City of Tigard Received Date/B Permit No.: 13125 SW Hall Blvd.,Tigard,OR 97223 Associated permits: Phone: 503.718.2439 Fax: 503.598.1960 11i, \I:D 24-Hour Inspection Line: 503.639.4175 ❑ Electrical ❑ Plumbing ❑ Mechanical Internet: www.tigard-or.gov 0 Other: THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW Ye. No N/-' 1 Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ 0 0 2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. 0 0 0 3 Verification of approved plat/lot. 0 0 0 4 Fire district approval required. Name of district: 0 0 0 5 Septic system permit or authorization for remodel. Existing system capacity 0 0 0 6 Sewer permit. 0 0 0 7 Water district approval. ❑ ❑ ❑ 8 Soils report. Must carry original applicable stamp and signature on file or with application. 0 0 0 9 Erosion control 0 plan 0 permit required. Include drainage-way protection,silt fence design and location of catch- 0 0 0 basin protection,etc. 10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state 0 0 0 building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. 11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if 0 0 0 there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction indicator;lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and surface drainage. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size 0 0 0 and location. 13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, 0 0 0 furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc. 14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- 0 0 0 floor,wall construction,roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings and foundation,stairs,fireplace construction,thermal insulation,etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. 0 0 0 Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full-size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- 0 0 0 prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing 0 0 0 locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered 0 0 0 systems,see item 22,"Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists 0 0 0 over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured floor/roof truss design details. 0 0 0 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required 0 0 0 for four or more appliances. 22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or 0 0 0 architect licensed in Ore on and shall be shown to be a licable to the ro.ect under review. 23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". 0 0 0 24 Two(2)sets each are required for Items 16, 19,20 and 22 above. 0 0 0 25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. 0 0 0 26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. 0 0 0 27 "Drawn to scale"indicates standard architect or engineer scale. 0 0 0 28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard 0 0 0 Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, 0 0 0 and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, 0 0 0 including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings on a lot of record approved prior to September 9, 1995. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Electrical Permit Application '':_ - . FOR OFFICE i. sl;Oy 1.1 City of Tigard SEP 9 2019 ReceivedDate/ Permit#: ■ 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review ' 3 Phone: 503.718.2439 Fax: 503.598.1960 (7.'e i `. Date/B : Related Permit#: f I.G A R D Inspection Line: 503.639.4175 b kj i m_ , .. ,_, .o `,; Ready Date/By- Juus: B See Page 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information 7'52 ..+.u..i r.. 6+xmwa-��oNr / "` �,;��s.. ..�.. . i„* s 6 5 .�� �s� .esrx,:T.Er€nnaoE:a,c;:rr.a600s;aawui':7 7,'"4x:2"7..... . .. ��a�� ,. „_,,,„ c a��r4;;sr�� � i. ”%t ,.4f `�9s�0��r& Please check all that apply(submit 2 sets of plans w/items checked): ❑New construction ❑Addition/alteration/replacement 0 Demolition ®Other: Solar PV Array ❑Service or feeder 400 amps or more ❑Building over three stories. where the available fault current 0 Marinas and boatyards. l ?' i ' t ® Y rtligaisulidarmi exceeds 10,000 amps at 150 volts or 0 Floating buildings. ❑ 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building less to ground,or exceeds 14,000 ❑Commercial-use agricultural ngs. ❑Multi-family 0 Master builder ®Other:Solar PV ❑Firesfor all other installations. Inbustallation pump. ❑Installation of 150 KVA or 11• ® 6 ` t ' t i ! ! ¢ rl;1 J ❑Emergency system. larger separately derived ❑Addition of new motor load of system. Job#: 177776 Job site address: 16854 SW Friendly Lane 100HP or more. ❑"A","E","I-2","1-3", City/State/ZIP:Beaverton,OR 97007 ❑Six or more residential units. occupancy. 0 Health-care facilities. ❑Recreational vehicle parks. ❑Hazardous locations. 0 Suite/bldg./apt.4: Project name: 177776 Ho Supply voltage for more than volts nominal. ❑Service or feeder 600 amps or more. Cross street/directions to job site: 1=: ;t s Description Qty. Each Total New residential single-or multi-family dwelling unit. Subdivision: I Lot 4: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel 4: • Ea.add'1 500 sq.ft.or portion 33.92 1 Limited energy,residential 75.00 2 7.875 kW Solar PV System to be Roof Mounted (with above sq.ft.) Limited energy,multi-family 75.00 2 residential(with above sq.ft.) Renewable Energy ® See Page 2 C.;1 PROPERTY OWNERANT 0 TENServices or feeders installation,alteration,and/or relocation Name: Shichun Ho 200 amps or less 100.70 2 Address: 16854 SW Friendly Lane 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: Beaverton,OR 97007 601 amps to 1,000 amps 301.04 2 Phone:(573)489-2079 I Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: shihchun.ho@gmail.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 1 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 "VMIt sxj ' ii ( BArFnhocibrcuh"cnwalttehratin,or extension,Qer panel Business name:Auric Solar LLC above service or feeder fee, 7.42 2 each branch circuit Contact name:Mitchell Hampton B.Fee for branch circuits without Address:9530 SW Tualatin-Sherwood Rd service or feeder fee,first 56.18 2 branch circuit City/State/ZIP:Tualtain,OR 97062 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:(971)803-1803 I Fax: :( ) Each manufactured or modular 67.84 2 dwelling,service and/or feeder Email:mttchell hampton(n7auricenergy.com Reconnect only 67.84 2 s9Ns 1 1( X11 a pct i ( Pump or irrigation circle 67.84 2 «R sinasa.jsante' A,.cic•Nalar.LLC. t-Sigaaraudistiliglatisig47,44 -1- Address:9530 SW Tualatin-Sherwooid Rd Signal t(s)or limited-energy panel,allteraiestion,or extension. 0 See Page 2 2 CitylState/ZIP:Tualatin,OR 97062 Each additional inspection over allowable in any of the above Additional inspection(1 hr mm) 66.25/hr Phone:(971)803-1803 Fax:( ) Investigation(1 hr min) 90.00/hr Email:mitchell.hampton@auricenergy.com Industrial plant(1 hr min) 78.18/hr Inspections for which no fee rs 90.00/hr CCB Lie.: 212831 Electrical Lie.: C1243 Suprv.Lie.: 6122S etclficall fisted 1,1 h�r mn �� t 4 i�lh11111 cM, .. C ,.ESuprv.Electrician signature,required:s„,../Ade Subtotal: 133.56 Print name: Thaniel Bishop I Date: 9/09/2019 ['Plan Review Required(25%of permit fee): �� � """ ,���,.����.���� State surcharge(12%of permit fee): Authorized signature:7/G!. .. p'S/Gi yN�/O )t, TOTAL PERMIT FEE: fv This permit application expires if a permit is not obtained within 180 Print name: Mitchell Hampton Date: 9/09/2019 days after it has been accepted as complete. * Number of inspections allowed per permit. I:\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(11/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: 440,;4,0 a.0 .,a,. � is psi€' as r _ ri: .art,*+CI'� �...,,., .�. . ... F..�.w„� ,.... ..., m... ........ .. Descr',tion • ®®EN Fee for all residential systems combined: $75.00 Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 0 100.70 _© 5.01 to 15 kva 111 133.56 133.56 gi ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 _© Wind l eneration s stems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 _© ❑ Garage Door Opener* 50.01 to 100 kva 552.26 _© >10witkhvOa Ae 9n8-c3c00an ■ 552.26 _© ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 I. 7.42 _® ❑ Vacuum Systems* >100 kva—no additional charge - 0.0 _® Each additional ins ction over allowable in an of the above: ❑ Other: Each additional inspection is ■ 66.25/hr charred at an hourl 1 hr min Inspections for which no fee is ■ 90.00/hr _. s.ecificall listed 'i4hrmin ,, :c.11111111.1 Ntrtn y aitiiDXKICNMIADXMi14fdkC Subtotal(Enter on Page 1): 133.56 Fee for each commercial system: $75.00 ber of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:\Building\Pemits\ELC_PermitApp_ELR_ERE.doe Rev 06/17/2015 City of Tigard '� Building Division liq S 13125 SW Hall Blvd, Tigard, OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 T I G A R D Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 16854 SW Friendly Lane City: Beaverton Zip: 97007 Owner's Name: Shichun Ho Date: 09/09/19 Contractor's Name: Auric Solar LLC CCB #: 212831 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? ® No OSSC or ORSC for design requirements. Is the wind exposure ® Yes If"Yes", qualifies for Wind Exposure « C or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ® Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than ® Yes the prescriptive path. above ❑ No 1 I:/Building/Forms/Photo V oltaic-Checklist.docx Is the construction material wood and does ® Yes Type of If"Yes", Yes , qualifies for the construction qualify Constructionas "conventional light 111No the prescriptive path. frame" construction? Is the spacing 24 inches or less? Pre-engineered trusses. ® Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? If"Yes", qualifies for Nominal lumber. ❑ Yes the prescriptive path. ❑ No Is the combined weight Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance ® Yes « with Section 305.4(3) of If Yes , qualifies for the 2010 Oregon Solar ❑ No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ® of wood one of the three types material roofing material shingle/shake checked, qualifies for the_prescriptive path. Max. two layers [ 1 of composition shingle. Is the roof mounted ® Yes Connections of solar assembly the solar assembly connected to roof ❑ No If"Yes",pqrescriptive p for to the roof framing or blocking the prescriptive path. directly? 2 I:Building/Forms/Photo V oltaic-Checklist.docx Is the gauge 26 or less? El Yes If"Yes", qualifies for ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mountedMinimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? El Yes the prescriptive path. ❑ No Is the roof decking of WSP min. '/2"thickness, n Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof ® Yes the prescriptive path. surface. ❑ No 3 I:Building/Forms/Photo V oltaic-Checklist.docx s Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size,type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: Jinko Model Number: JKM315M-6OHL Listing Agency: UL 1703 4 I:Building/Forms/Photo V oltaic-Checklist.docx