Loading...
Specifications (45) MST2019-00222 114229 SW 169TH AVE Roseburg MST2019-00223 14233 SW 169TH AVE $—+ r w 3-15-16 ,„„,, Za i � `� P 7:10am lrot,I I'nxiuctsCompam MST2019-00225 114239 SW 169TH AVE 1 of 1 CS seam 2016 1.0.13 �, MST2019-00226 14241 SW 169TH AVE i- EB 07 2019 kmBeamEngme 4.13.15.] � Materials Database 1547 ” ' MST2019-00227. 14249 SW 169TH AVE materials Database 1547 & k.;1IYOF it Hr) Member Data 3t �,r, Description: O�� Member Type: Joist Application: Floor '4''-�` Ei'''�''. ''° Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PSF Deflection Criteria: L/480 live, L/240 total Dead Load: 12 PSF Deck Connection: Glued& Nailed Filename: Beam1 T ., 1f` / / / 14 9 0 10 3 0 0 o / / 2500 Bearings and Reactions Input Min GravityGravity p Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall DFL Plate(625psi) 2.750" 1.750" 425# — 2 14' 9.000" Wall DFL Plate(625psi) 3.500" 3.500" 1097# — 3 25' 0.000" Wall DFL Plate(625psi) 3.500" 1.750" 287# -36# Maximum Load Case Reactions Used for applying point loads(or line loads)to carrying members Live Dead 1 332#(249plf) 94#(70p1f) 2 844#(633p1f) 253#(190p1f) 3 240#(180p1f) 47#(35p1f) Design spans 14' 7.125" 10' 0.375" Product: 9 1/2" RFPI-20 16.0" O.C. PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1302.'# 2820.'# 46% 5.99' Odd Spans D+L Negative Moment 1449.'# 2820.'# 51% 14.75' Total Load D+L Shear 605.# 1220.# 49% 14.74' Total Load D+L End Reaction 425.# 1048.# 40% 0' Odd Spans D+L Int.Reaction 1097.# 1775.# 61% 14.75' Total Load D+L TL Deflection 0.2330" 0.7297" L/751 6.72' Odd Spans D+L LL Deflection 0.1866" 0.3648" L/938 6.72' Odd Spans L Control: Max Int.React. DOLs: Live=100% Snow=115% Roof=125% Wind=160% SIMPSON All product names are trademarks of their respective owners KAMI L HENDERSON EWP MANAGER Strong-Tie Copyright(C)2016 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED. PACIFIC LUMBER&TRUSS "'Passing is defined as when the member,floor joist,beam or girder,shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet.The design BEAVERTON,OREGON must be reviewed by a qualified designer or design professional as required for approval.This design assumes product installation according to the manufacturer's specifications. 503-858-9663 J4 MAIN 3-15-16 t4Roseburg 7:08am 1 I cre[Products f r ri(c cr I of 1 CS Beam 2016.1.0.13 kmBeamEngine 4.13.15.1 Materials Database 1547 Member Data Description: Member Type: Joist Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PSF Deflection Criteria: L/480 live, L/240 total Dead Load: 12 PSF Deck Connection: Glued& Nailed Filename: Beam1 Other Loads Type Other Dead (Description) Side Begin End Start End Start End Category Point(PLF) Top 0' 0.00" 0 80 Live Point(PLF) Top 0' 0.00" 50 34 Roof Y / 2000 1050 0 1430 o/ 2680 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 2' 0.000" Wall DFL Plate(625psi) 5.500" 3.500" 643# - 2 12' 5.000" Wall DFL Plate(625psi) 5.500" 3.500" 1038# - 3 26' 8.000" Wall DFL Plate(625psi) 2.750" 1.750" 418# -- Maximum Load Case Reactions Used for applying point loads(or line loads)to carrying members Live Roof Dead 1 367#(276p1f) 82#(62p1f) 276#(207p1f) 2 832#(624p1f) -17#(-12plf) 205#(154p1f) 3 323#(243p1f) 2#(2p10 95#(71 plf) Design spans 2' 0.000"(left cant) 10' 5.000" 14' 1.125" Product: 9 1/2" RFPI-20 16.0" O.C. PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1260.'# 2820.'# 44% 20.17' Odd Spans D+L Negative Moment 1318.'# 2820.'# 46% 12.42' Adjacent 2 D+L Shear 582.# 1220.# 47% 12.42' Adjacent 2 D+L Cant.Shear,Lt 290.# 1220.# 23% 1.99' Total Load D+L End Reaction 418.# 1048.# 39% 26.67' Odd Spans D+L Int.Reaction 1038.# 2000.# 51% 12.42' Adjacent 2 D+L TL Deflection 0.2159" 0.7047" L/783 20.17' Odd Spans D+L LL Deflection 0.1684" 0.3523" L/999+ 20.17' Odd Spans L TL Defl.,Lt. 0.0458" 2L/999+ 0' Odd Spans D+L LL Defl.,Lt. -0.0327" 2L/999+ 0' Even Spans L Control: Max Int.React. DOLs: Live=100% Snow=115% Roof=125% Wind=160% Left cantilever allowable shear is for joist only SIMPSON All produc names are trademarks of their respec ive owners KAM I L HENDERSON EWP MANAGER .StrongTie Copyright(C)2016 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED. PACIFIC LUMBER&TRUSS "Passing is defned as when the member,floorjoist,beam or girder,shown on[his dravang meets applicable design cdteria for Loads,Loading Conditions,and Spans listed on this sheet.The design BEAVERTON,GREG N must be reviewed by a qualified designer or design professional as required(or approval.This design assumes product installation according to the manufacturer's specifications. 503-858-9663