Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (182)
?"..- Markup Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND u, Delete Line //\\✓/� OO XXX-XX BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). o G VES=INTERLEVEL CS, LCTIONS/SUPPLY. w BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. O - o MAXIMUM SPACING(TYP) a.. Add Line - SPRINKLER MODEL(TYP) = 1/2"PIPE SIZE > o HEAD SYMBOL(TYP) ��. =3/4"PIPE SIZE -'va° Add Tee I I I —I� = 1"PIPE SIZE O a u — — = 1-1/4"PIPE SIZE m 3°''s ft Add Elbow w yy�j V.VI Z Z a Add Coupling I W t"° �mvw3 RECEIVED ",Q20, Add Head -8--E)--10- I. i, O f'H w a Delete Head 0- .4-- - - -- AUG 1 3 2019 0 z z ¢ Move Head 0- ,0- 1 CITY OF TIGARD � �° oo°wm�=t roy BUILDING DIVISION oz g , f� ' Note:All revisions must be reviewed by Uponor 4 , ,?,R4,1 .,°'8 c� NC - Table F002-1 ,._ �. 1 ,,';'=".4,4'84,`.2,,v,4 ?- 11 CC ^I I c�zz� p°,' m�,z Multipurpose Fire Safety Systems ( ooa9}�;¢� _� z The Uponor Residential Fire Safety System is a residential fire protections ` ` ` S z Z o o a o o a ag g system installed in combination with the cold side of the domestic potable d' °z o A w 4� F. "i T � }�t]a- �-� a° water system. Only licensed contractors trained by Uponor can install this I�I ` f o z;s y a z a o a Ctrf system. w zaoaat,'ziw,q . Q F.0,4150 -�>3z 44 What to do if Changes aro Required —_ ___._-- - J 6zca,"�`31=.f'0,5Q r If any features or obstructions require the addition or deletion of sprinkler V)z:',.',?,t 5 i oe ft u 1� heads,or significant relocation of sprinkler heads,contact the Uponor Design ^'t m m o ft a o a h_ l� Department to determine if observed changes require a redesign O m h o= -z 5 u?,�, W. (888.594.7726). 02'5o2S"S�o;N j 0,E1d'� zuo',o fv S.1 MAIN SHUTOFF °oma°❑ Fu°_�;Nc W. VALVE LOCATION 3 0 w a o. z u a m C UOZ.mOSCON�07°}� MOST HYDRAULICALLY REMOTE HEADS HEAD# GPM PRESSURE REQ'D AT STREET / o� m3 u}�>¢ .to 1 HEAD H.2 13 24.59 co��a�xa ,9,: 2HEAD H.6&H.5 26.00 41.66 F 1}"AquaPEX m�f0m�=�€fro ,yam TO SYSTEM ,n= -3V"'- , 41 j 1 T.35 ®® SENJU Model RC-RES Residential Flat Concealed Pendent SS8464 -1.3. 1L...11...,:° V ti;• 6 0 - - - 12 K=4.9, 162F°,7/16"Orifice,Maximum Spacing 16'x16' I N. RC-RES-16 Sprinkler head demand: 13 gpm @ 7.04 I here by certify that this plan,specification, Eor report was prepared by tee or under my SENJU Model RC-RES175 Residential Flat Concealed Pendent SS8464 I , T.37 direct supervision and that I am NICET ry 0 - - - 1 K=4.9, 175F°,7/16"Orifice, Maximum Spacing 14'x14' Certified at Level IV. RC-RES-14-175 Sprinkler head demand: 13 gpm @ 7.04 i' ry a I Brent D Kotula T.3 r ________1 Date: Reg.No.113889 3 1st Floor r8 8 2nd Floor an 2 Basement ni I 3 TOTAL I ri_fT.3,° .--- `'-j INTERLEV 12 CONNECTIONS FROM EL _ I Z BASEMENT TO FIRST FLOOR \ -T. '4414�' CITY O F TIGARD w m \ L[) a f m — — 1/101 Approved M ;� ' _° Conditionally Approved ~" CURRENT STATIC \ 1 J?01 " II c \ r W 'ao°m Ca WATER PRESSURE See Letter to: Follow L( U < ' ^ L " ____,A.,1, � Ariached n STATIC: 55psi ('-IL- 11 Permit Number.fncr�.Sh"paa S __ =o w o Pi 'EXTERIOR WALL T ` L t Jr.�ZvO fhsl (�04A (04ff rc.t W z b G u a, / ELEV=108' . Address: a 5=J c \/ By Ae 6 Date: l� °°s<°1o0 9►- 7L_ l�j f= ILrL SLLI LU E S 1 1/4"AquaPEX ` ' *IT T� it / \TO SYSTEM L J Ce o / TO HOT WATER HEATER 1 I re' DC w o / ELEV=104' �� ¢ O o c=7~O N 1"WATER METER 4 Y ° to ^ STANDARD LOSS PER NFPA-13D 1 1/4"FULL PORT } } 0 u w M m (3PSI LOSS FLOWING 23GPM) / BALL VALVE Q M u m EO m UNI 5, EL a 'mw�!w ° te ELEV=100' ELEV=100' / • p 0 3gaga w G 1 y /i/i////////J o u d z 0 1"METER 35'OF 100'OF SHEEBASEM NTTION 1"COPPER-K 1 1/2"AquaPEX 2 WATER SERVICE DETAIL �� BASEMENT LEVEL 5 0 5 15 SHEET NUMBER F 1 0 0 1 1 n t 1oo NTS \lo�/I i/^ii _ i '-O" 1/4"=1'-0" 1 `F L © UPONOR - CONFIDENTIAL F- Markup Legend Delete Line /y� /� 0 N 0 -, U z z Add Line `n a% T �2S Add Tee 0 N g, Add Elbow Id O V v w3u-w0 p Add Coupling H M w n p I I y�Vw3 w"m d 3 I 1 I N�of Qm Add Head 1 2 3 c,°n i-w 3 E i I Delete Head -- t z, oaeo o=tea JI oy 4o z � r I a =q =ym° w Move Head - - uguz 000wy� u O O Z ty Note:All revisions must be reviewed by Uponor i-�. 1 m o f°, ;�s i II II �a¢ e c N do °po°' , a� z Multipurpose Fire Safety Systems z° N _ ho °oaooo0o The Uponor Residential Fire Safety System is a residential fire protections dmoma ci aWsystem installed in combination with the cold side of the domestic potable water system. Only licensed contractors trained by Uponor can install this 'I- --4--l 2 oa2; A E< system. -__0 0�_ • / 4 Qaz451iEQ43 oz What to do if Changes are Required I rf r (pU yaw ourwoyS �uF If any features or obstructions require the addition or deletion of sprinkler m�uoaouoheads,or significant relocation of sprinkler heads,contact the Uponor Design wow zrVBu � •Department to determine if observed changes require a redesign _ E�❑Z oCou- l(888.594.7726). Z�Lw�Ea»=-A$ 1 'aauo �o�e`,�iozd o,oz fi28L1o�>o SPRINKLER SYMBOL DEFINITION I O j `o� m2u �gaeFo XXX-XX H.9 — r-- 1°.4 �ooaz_�_mmm�- MAXIMUM SPACING(TYP) _ RC-RES-16 I J p a� 1 4,>_ =3o- =wya w SPRINKLER MODEL(TYP) P T22f—R,_:Es.11--- Lil Fv,hl- ¢uu?`�Fc`�a HEAD SYMBOL(TYP) •J 0� -I • R � COLOR/LINETYPE LEGEND � ; � _ � � _ I BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). ___ ___ GREEN LINES= INTERLEVEL CONNECTIONS/SUPPLY. I •T A s___ I here by certify that this plan,specification, a BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. F.5 ❑ _ J- — or report was prepared by me or under my n .u— = 1/2"PIPE SIZE .I F.3 ■ o — - — _ I 11 ,I fd pC direct su ervision and that I am NICET —s— =3 4"PIPE SIZE il' F.2 _ I certified at Level[v. 1 r 1"AQUAPEX INTERLEVEL �I� =1/PIPE SIZE I I H.10 ( — _ — CONNECTIONS FROM FIRSTS Ti... II+I FLOOR TO SECOND FLOOR \ i l; Brent D Kotula c = 1-1/4"PIPE SIZE UJ RC-RES 1 i i / ! 1-.11. P' .1 _. ® NE g. I —T'— / L Date: Re No.113889 I IIMVIA k / ..---- / \ \ X1,1 I �'I' • �.,ES 16 0 / / 5123 T I,��� p Fr i rd '\2 .27 o. / 1111111 )I ��J Ji nfwMIA. �Q` lfl o M c \�• 1 !Rai Z V II ili LIJ (!9 RE�� � �n _ 1 1 T.2 U WW ' 31 _ _ _ j Q 3 9.9 \ M 0 • F7' 1II \ — = a_ 1"AQUAPEX INTERLEVEL W H,l' __ ce w t_11._ \ K CONNECTIONS FROM FIRST \ ..1 H� L_L_ zSO I' FLOOR TO BASEMENT 1 i 1 \ LLJi a t= a—r GI R RES4 6 RC-RES-16 RC RES-16 Rid• g a a¢o L E u m �..�/ /` I ISL O O c�i a s v=i o 0 IL- LLJ ui w n - °6:12 6:12 c �/ o TQi PIT 4 LL Y Q O ops �Y 6 Q �iW �N m o 1 FIRST FLOOR Q < ��f..o 1 SECOND FLOOR &I £,m 1t o F101 ==LL 1�41i = 1i_Dii F102 - 1/41t _ 1i_Ofi j gi,=FFa o SHEET DESCRIPTION FIRST FLOOR AND SECOND FLOOR m SHEET NUMBER 5 0 5 15 2 — v F 1/4"=1�.D„ © UPONOR - CONFIDENTIAL F101 F- rm Senju RC-RES:Open Web Truss/TJI Construction Insulation Recommendations See General Notes 8.2.5.7 for Architectural AquaSAFETM GENERAL NOTES: In areas subject to freezing,care should be taken in unheated attic spaces .. ProPEX LF Brass Fire to cover Uponor AquaPEX tubing completely with insulation. Insulation Feature Requirements S Sprinkler Adapter Tee should follow the guidelines of the insulation manufacturer. See Uponor Z 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2016 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM BlockingMaybe Fire Sprinkler Adapter F f SECTION 3.3.11.3. Y Document"Uponor AquaSAFE Attic Insulation Guidlines"for attic , on Nut >:" u Required.If installation guidelines(Provided in Contractors Documents package or online 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON Blocking is Used, `�, m 11/4"Min at www.Uponorpro.om). 0 -' 0 THIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND Use The 2 Top 1 I/2"Max. "'CCC I 1777"' >^a UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. Screw Holes. .9'' / Bottom of Mounting Extreme Temperature Installations Planter Box Window,Bay Window or Similar Feature. .. Q --__� �ractet to Face of Truss AquaSAFE Residential Fire Safety systems are often installed in attics or If no additinal Floor area is created No Additional Sprinkler is Required. o.m Ud v 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE 0 <..m w¢ Fire Sprinkler Ada ter -' __ _ " other areas exposed to temperature extremes of heat and/or cold. Follow 8'-0"or less N j'' c RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE Mounting Bracket the recommended extreme weather installation instructions to isolate and / o, PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE I - \g�J I protect system components from extreme temperatures. Because this RC-RES-16 w 3 u.w O SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE U v m Z SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. + •{� system also delivers domestic cold water directly to plumbing fixtures, ® \ 3-#10 x 1 1/2" 9'-0"or less j.`ry z Full Course �I - } Uponor highly recommends that you protect the tubinIg with adequate / v W N^l9 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH Thread Screws insulation in warm weather areas to minimize heating of the cold water \ ,/}r NFPA 13D 2016 EDITION. In Bottom Holes supply' c w c z a O 3 5. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE NOT PERMITTED TO USE ANTI-FREEZE. .. - \ Installation methods include,but are not limited to: i�'o\ i \ w m E w ...F° _ • Tenting over the fire sprinkler piping. O m H w 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR Lead-Free Flat - • Additional layers of batt insulation. If additional floor area is created.Cannot exceed 18 ftz,be more than 2'-0" DAMAGED MUST BE REPLACED. Concealed Senju L Concealed Flat • Increased depth of blown-in insulation. deep,more than 9'-0"wide and be with in the coverage area of the o Sprinkler Head Cover Plate sprinkler.No Additional Sprinkler is Required. p 0 0 5 z >H 7. WATER SHUT OFF VALVE IS NOT PERMITTED THAT ISOLATES THE SPRINKLER SYSTEM. Caution: If you will be installing spray foam insulation,make sure to S S a f o iu a o 0 6. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. Senju RC-RES:Traditional Wood Framing Construction protect all components during application.Consult with the spray foam i 0 5 o 0 0 2 m 5 w manufacturer to ensure compatibility with all products before application. NFPA 13D Table 7.5.5.3 Distances From u i o z 1"°i¢o z 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING,THE Heat Sources I-ti o o v o E m WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND Consultation with local building officials is encouraged to ensure compliance F N m a= p PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR _ with local b_uildln codes. - o f w z-''u ProPEX LF Brass Fire g Ordinary Intermediate �0 3 o Si< AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, Sprinkler Adapter Tee Fire Sprinkler Adapter -- °p 0 i z FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM ry[Push-on Nut Heat Source Temp. Temp. �'z z y r o m ti WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE �•-'- LLLLL��. 135°-170° 175°-225° 2,2,-, n'w,1-•-•"i"--:6 THIS SIGN". Bending PEX Tubing Side of Fireplace 36" 12" 2.Vp°Oz^yoo3E-1 D, �' / 1 34'Min. The minimum bend radius of Uponor PEX tubing in any direction is six times re 0 5 w 5 o a°t•a¢a 5 10. ALL INTERIOR PIPING TO BE UPONOR"AquaPEXIR"UNLESS NOTED. -_,- 1 YZ'Max. the outside diameter(6 x OD). Front of Fireplace 60" 36" W°o m h o=E z a 3 0 Fire Springier der Ada ter Bottom c f Mounting Wood Burning Stove 42" 12" f w¢z z v;a y P p Bend supports are available for 3/6",1/2",3/4"and 1"Uponor AquaPEX gw re o¢a ` Bra<ke[ta ace of Truss ¢Ft=zzZOO�ari,>'�5 11. UPONOR"AquaPEX"TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. Mounting Bracket �_©�J O tubing to facilitate 90-degree rigid bends. Kitchen Range 18" 9" .,a z u o 0^ a, >m W _0<Z' EO Wall Oven 18" 9" V 505 c¢2c wm0 5F.€ 12. MINIMUM SPACING BETWEEN SPRINKLERS IS 8'-0" REFER TO SPACING CHARTS FOR MAXIMUM SPACING 2-#10 x 1/2" Recommended Tubing Length Between Fittings Hot Air Flues 16" g^ 0)z„u;61° i°o u r u BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE Full Cour )- t tr w ti 0,0 o=-�a rZj o y"= RESTRICTIVE SPACING LIMITATIONS. Thread S rews �T I f i t Fitting Size Minimum Tubing Length Uninsulated Heat Ducts 18" 9" m z o z_ s�+�r z�i N In Top H es U U 3/8"ProPEX Fitting 2" Uninsulated Hot Water Pipes 12" 6" 5 o z t 2°o a m 5 o 13. SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING - Side of Hot Air Diffuser 24" 12" or� g c z u°o MOUNTED OBSTRUCTIONS. 1/2"ProPEX Fitting 2" - 3 0.0i,i p 0 i,F„u g C z° Front of r Heater Diffuser 36" 18" 3 o�g y s w f�z ii¢o 14. THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE - _ 3/4"ProPEX Fitting 3" Hot Water 6" 3" o z o ¢u o 0 o' ui F m SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. Lead-Fred Sesq °°o w m o m o"' o r° Concealed Senju : \' 1"ProPEX Fitting 3 1/2" Furnace 6" 3" >m o u>a z v, 15. THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN Sprinkler Head CoveConceaPlated Flat 1 1/4"Pr0PEX Fitting 4 1/2" Light Fixture ? u°�€ o m DSOW-250W Li h CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT IS 250W-499W Light Fixture 12" 6" a H` ,,,3 4 550 U z a THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. \ '� �i o z o os S a w 16. NFPA 13D 8.2.5*OBSTRUCTIONS TO RESIDENTIAL SPRINKLERS Exposed Installation Requirements. '''''''''-'°""`� vi • 8.2.5.6* SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS Uponor AquaPEX'"r tubing(white)and ProPEXrM EP Fittings and ProPEX'M \ THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FT0 PER SPRINKLER. Brass Fittings are approved for exposed installation where the following • • 8.2.5.7 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY conditions are met.(UL 1821 Approved) WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO Exposed Wood Joist Ceiling Assemblies. o ni /r),, ❑Um ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. n Q 1. Joists are of dimensional lumber,engineered wood,wood I-joist or openI here b certif that this Ian,s ecification, E (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONALweb wood joists. y y p pSPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; I m or report was prepared by me or under my `r�i (a)THE FLOOR AREA SHALL NOT EXCEED 18 FTS(1.7 Mz) 2. Joist are of depths from 6-16 inches(152-204 mm). direct supervision and that I am NICET 3. Joist are of spacing from 12-24 Inches(305-610 mm)on center. ❑ Certified at Level IV. -• (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 2 FT IN DEPTH AT THE DEEPEST POINT OF \ THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED 4. Metal can be exposed aftereinstallation. \ ALONG THE FINISHED FLOOR. 5. Metal pipe hangers spaced at maximum 24 inches(610 mm)on center 1.55" 1.66" n aret used. In / Brent D Kotula (c)THE FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE 6. Listed residential automatic sprinklers of maximum activation c PLANE OF THE PRIMARY WALL. temperature rating of 155.F(68.C). 2 - n Hanger 1" Hanger Dale: Reg.No.113889 (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER I SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. Metal Tubing Support. Tubing Support Spacing: 3 THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE q gSecurely EnoughSupport the Tubing,Yet Relaxed ( ) Q (Anchor AquaPEX Tubing to in ARCHITECTURAL FEATURE. 1. Metal tubing supports designed for plastic tubing shall be used. Enough to Allow the Tubing to Expand and Contract) e 2. Do not use supports that will damage the tubing.Inspect metal Y 17. NFPA 13D 8.3 LOCATION OF SPRINKLERS. supports for sharp edges. 1. Along Horizontal Runs,Install Supports Every 32",if Horizontal Runs are 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 3. Do not rigidly anchor Uponor AquaPEX"tubing with supports.Allow Continuously Supported,Place Tubing Supports at Six-Foo[Intervals.• THROUGH 8.3.8. enough tubing for freedom of movement to expand and contract. 2. Along Vertical Runs,Install Supports Every Four to Five Feet,at Each > 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FT'(5.1 MT)AND LESS Floor and at a Mid story Guide. 0 • 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT z MEET ALL OF THE FOLLOWING CONDITIONS: (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FTT(2.2 M=). In-line Flow Test ° 1,1 (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLEThe In-line Flow Test can be constructed on site. It performs a flow test to o`Standard Riser Assembly ensure proper system operation and flow(see Figure FO01-8). t u zt 2 t 0 MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. In a multi-purpose system a single control valve controls both domestic and z m t •• 8.3.4* SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND Z y n Mc SIMILAR STRUCTURES fire safety needs. LLJ 7 a"'m n • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE % Uponor AquaPEX d,,,,, , ` Q 0 m r 5 EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND Tubing Y%/�%/////////f, �../ CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, w n CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING r PURPOSES. N • 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR - • 1`" '• s o ..o p 8.3.5.1.2. r -- io-w u a V • 8.3.5.1.1 WHERE THE FUEL-FIRED EQUIPMENT IS ABOVE ALL OF THE OCCUPIED AREAS OF THE DWELLING °Is �, ‘,5j¢G z o ^ "a UNIT,NO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. ' • • g z i a U 8.3.5.1.2 WHERE FUEL FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE O O o J:i.': x m w Male Threaded Coupling ProPEX Fire V O u a a m z0 O • DWELLING UNIT,AT LEAST ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE Sprinkler Adapter LU in INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIRED w EQUIPMENT FROM THE OCCUPIED SPACE. • 5 • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN COVERED,UNHEATED PROJECTIONS OF THE BUILDING AT • To Hot Water Heater Male Threaded Coupling - 1"Ball Valve oa ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. - �..�/1-1 z0 3. 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING t,�/�1Female Threaded LL v� 9 CONDITIONS: E N Tee with Water (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED N '�,� Pressure Gauge ce z 0 100 FTs(2.83 M3). _ Sprinkler Orifice (Optional) s= O `^ (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS t c 0 F- a AT THE LOWER CEILING ELEVATION. e s " > m E. E Uponor Warning Signs n=w (3)*THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE _ Flow Test ¢ M TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. To ensure the system provides enough water for proper fire sprinkler m m.• mperformance,you should conduct a flow verification[es[. (4)SKYLIGHTS NOT EXCEEDING 32 FTS(2.97 M')SHALL BE PERMITTED TO HAVE A PLASTIC COVER. vCJI .. - m • 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS o Note: The NFPA 13D Installation Standard does not require flow C// (3 m i w' o F (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR 5 to ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED n .-, verification. O H z x PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. - _ a ": Main Fire Sprinkler ��.�// 1L- rr • 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING Shut-off Valve Before performing a flow verification test,confirm the water pressures by Ci r o w K IS xc z contacting the Water and Sewer Department of your local city. Ensure the a o u N E d i EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. o S available water pressure matches the pressure used in the system design. t 18. INSULATION GUIDE LINES PER NFPA 13D. Note: The sprinkler plan indicates the most hydraulically remote sprinkler SHEET DESCRIPTION S • 9.1.1*WET PIPE SYSTEMS IN AREAS ABOVE 40.F. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE '41- o (or pair of sprinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DETAILS in USED WHERE ALL PIPING IS INSTALLED IN AREAS MAINTAINED ABOVE 40.F,INCLUDING AREAS PROPERLY a • your local code. INSULATED TO MAINTAIN 40°F. me• A.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO Note: It is a good idea to notify the fire inspector at least 24 hours prior to COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE performing a flow verification test. This may speed up the inspection GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.1.1(A)THROUGH FIGURE A.9.1.1(F) process and eliminate the need to repeat the test for the inspector. SHEET NUMBER SHOW SEVERAL METHODS THAT CAN BE CONSIDERED. THESE ARE FOR ILLUSTRATIVE PURPOSES ONLY. .Z CONSULTATION WITH THE GENERAL CONTRACTOR AND/OR OWNER IS RECOMMENDED TO ENSURE Note: See"AquaSAFE Flow Test Instruction Sheet"(Provided in PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 40oF WILL BE MAINTAINED. _ Contractors Documents package or online at www.Uponorpro.com)for t more information on Flow Test Setup,Assembly,Performing the Test and F --- Troubleshooting. If there are any questions please contact Uponor. I- © UPONOR - CONFIDENTIAL FO 0 1 a Markup Legend SPRINKLER SYMBOL DEFINITION , COLOR/LINETYPE LEGEND IMO • - //\\J/� OO XXX-XX BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). f o KEEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. w BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. o Delete Line MAXIMUM SPACING(TYP) ........0.••••• = 1/2"PIPE SIZE > o Add Line — — — — SPRINKLER MODEL(TYP) E HEAD SYMBOL(TYP) J •ate =3/4"PIPE SIZE a..B ou Add Tee I i I —I— °'�u� =1-1/4"PIPE SIZE i z y'Aj�LLwO Add Elbow LI Q j Mz ry Q C�^t7� Add Coupling I = u,--.L, t \ 1. f°rv°J a W Add Head 1-- 2-- 3- t li Cv°'i F-W 3 Delete Head 1 \—' I o} HOAR �'-.. v= Foo om 3 '�� c oo"'y�� Move Head y ^°y NzYa�o zgUoz ♦ 4000Szz �_md Note:All revisions must be reviewed by Uponor I -' .-- Table P002-1 , - -. ,. iz_° >3 z o ughU�o3z< Multipurpose Fire Safety Systems i°V m m z o The Uponor Residential Fire Safety System is a residential fire protections g o o z W a°a H u ofS of z system installed in combination with the cold side of the domestic potable CL E o_a 9 ti g F>a a water system. Only licensed contractors trained by Uponor can install this - H olozz=au 5}F ow za a>�system. What to do MChanges arc Required iIVd _ Oo h If any features or obstructions require the addition or deletion of sprinkler Hwia F.Q. az =� ti heads,or significant relocation of sprinkler heads,contact the Uponor Design QmHioa d u Department to determine if observed changes require a redesign , =xwood " o(888.594.7726). '93 ya oL"�ya`fzyaozd MOST HYDRAULICALLY REMOTE HEADS 11,"AquaPEX AooWmou `�'� `wFo HEAD# GPM PRESSURE REQ'D AT STREET TO SYSTEM ' = 000�FaouZ � 1 HEAD H.2 13 24.59 AilIli T.34 a9ti 6 4,,,;°Za �u uyyore'm� 2 HEAD H.7&H.8 26.00 41.67 S.1 MAIN SHUTOFF I _se .35— a o z °o"°s w`°' L VALVE LOCATION 'I �u,yti uauu?�I-o'�a en T.36 I SENJU Model RC-RES Residential Flat Concealed Pendent SS8464 v 1•••••• . ® - - - 12 K=4.9, 162E°,7/16"Orifice,Maximum Spacing 16'x16'E 1.37 RC-RES-16 Sprinkler head demand: 13 gpm @ 7.04 I here by certify that this plan,specification, or report was prepared by me or under my O SENJU Model RC-RES175 Residential Flat Concealed Pendent SS8464 direct supervision and that I am NICET m 0 - - - 1 K=4.9, 175F° 7/16"Orifice,Maximum Spacing 14'x14' 7I vl certified at Levet IV. RC-RES-14-175 Sprinkler head demand: 13 gpm @ m 7.04 T.38 0 , I Brent D Kotula 3 1st door I ----. I Date: Reg.No.113889 I 8 2nd Floor 2 Basement ° 13 TOTAL LT _ u IT e F x - _ , 1 • 1 Q f` 9 C1NNEAQUCTIOEX INTERLEVEL EL ' CONNECTIONS FROM — BASEMENT TO FIRST FLOOR ' jl11 — _ _ — � m L 11. iii oC fw .� / oC - II Ir / l� Z Z •a ,r , 1 CURRENT STATIC / a a N F ., WATER PRESSURE EXTERIOR WALL T SI > °r m ELEV=108' r ; c ' `� w N STATIC: 55psi \ fl �' J\ I I J i o w z S 1 1/4"AquaPEX I T U > o. u ` / TO SYSTEM Q aaQzo W E / s.1 TO HOT WATER HEATER ' , ` J+ �i? ` \` Ce 0 0 <°m a o m / ELEV=104' LLJ 11 11 m 1"WATER METER L-� STANDARD LOSS PER NFPA-13D / �1 1/4"FULL PORT W o a (3PSI LOSS FLOWING 23GPM) / BALL VALVE 1. O o G / . O�o p1d® ® / Qp6, zWo ELEV.--100' ELEV=100' BASEMENT LEVEL ce o /i//////////1 1 Q L„ 1"METER F100 = gym fE a 35'OF 100'OF 1/4" = 1'–OIL 0 1 w g F g2' ° 1"COPPER-K 1 1/2"AquaPEX H Si 3 w p c a SHEET DESCRIPTION BASEMENT N • T ,' 81 !2- WATER SERVICE DETAIL 5 B 5 15 SHEET NUMBER S,' 11111111111111.111111 F\ 100/ �� �� 1/4"=1'-0" NTS © UPONOR - CONFIDENTIAL F100 I- Markup Legend Delete Line C 1 O O U d O z Add Line '`2 E Add Tee O -,,,*;A VW3L0 Add Elbow K n Z a Add Coupling I aW-- I,m J 3 \ \ I W L423Q W Add Head -@--�.2--(0- t 'T I 0,n r2w 3 I1,( Delete Head -IXI- —+/� t z. oa o ow ll�'I'll .� Y P30-6t.ThEl';3 Move Head -O- -O- �' �' • t i ?Nzo¢'��go°a a' sc °, a Note:All revisions must be reviewed by Uponor LL w a z s j o E�oSoyzw `�m� m8 T f u �aLL°p�uiou wm waz > Multipurpose Fire Safety Systems ■ e� Il ' I ( z o a l r l;;K g The Uponor Residential Fire Safety System is a residential fire protections / S o o°°a o a - o system installed in combination with the cold side of the domestic potable t \ p'° °f o �=z° ¢a E water system. Only licensed contractors trained by Uponor can install this W S c S y SS U, i F zd 3` E system. / ' �°<z¢a=�;o '^zo �µ�I / Q,a,z000zoo, Q�o3z What to do if Changes are Required II 't'� I Uz='°'aw� du¢d1F If any features or obstructions require the addition or deletion of sprinkler I 1A y v p i°o u`�'u u heads,or significant relocation of sprinkler heads,contact the Uponor Design C-RES-16-1 I 'A,-- ,1-2.;:i'8,-!, a a a o ti'A v a,a,,,, w omF�awsa _z u Department to determine if observed changes require a redesign ' — A m s o g U u S,'4 E F C _ - N ayou°oma w (888.594.7726). � H.9 I�I � ,1A o¢m��om Fwa�u�° -zf1 f lim ___ IY' 3w ''Oe,y,>u`«Z RC-RES 16 SPRINKLER SYMBOL DEFINITION , — °a`-Ns`E 'za o0,4 ° / �z°dmuoowoyviFw O• XXX-XX i I 9 w °� >1Sa�Fu d LL / o°pmFa,,,J1Eawz r a.� � =hyo„m '6, - 1*,r C ��x 35zoa MAXIMUM SPACING(TVP) - I �IAI 77111Lierz:T[lor_iN” II.1: =u,,,L., zoza$zave‹yu w• SPRINKLER MODEL(TYP) \ / V.. L r-�,H«-uauu_`�F°'�`¢HEAD SYMBOL(TVP) J ❑ F.5 \ \ \ \ ....— r / / ----- •� � .1 �.. I.16 '^ COLOR/LINETYPE LEGEND BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). o 1 F.2 \ 1"AQUATIONS FROM FIRST /_ — _ — — — �IrI i� T 51.3 CONNECTIONS FROM FIRST�— rFC GREEN LINES= INTERLEVEL CONNECTIONS/SUPPLY. - — --. FLOOR TO SECOND FLOOR — --- RE; 6 • I here by certify that this plan,specification, BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. H.10 / _ _ — — / \ II 1 —I fig/ or report was prepared by me or under my �s� = 1/2"PIPE SIZE " ? I� // V direct supervision and that I am NICET RC-RES-16 // \ , I 1. / Certified at Level IV. =3/4"PIPE SIZE T.25 P _4 I /------ Z1 — r I. — 1` = 1"PIPE SIZE i j/ '' Brent D Kotula 14/4"PIPE SIZE / 4 Date: Reg.No.113889 c. I <*F ,' H.6 w HJ 10 o / T.2 \ \ 41:;_. 16 RC-RES-16 RC-RES-16 Rd-RES-16 Y �4� 1 T' . \ \ 0 12 H.1 \\ . . .. .. .. , i=e x61 z T' -'�� •_ ❑ \ b12 6:12 —� 0 a f a A c � Ce \ 0 M m m 19.9 III A% K,R711 . I 'O \ * r Qzy ry II t / FTE O 0 -- = - 1"AQUAPEX INTERLEVEL <8 m-\ .2 / 32 ❑ I — _ — — _ --- ___=—__,- CONNECTIONS FROM FIRST Z <t2 E I 00 "�I_ FLOOR TO BASEMENT tC3 2 rr w 4. . 1 Eczeczef u08aawza 0 I— w , oc w o 1. . 1. O og o 4. O o t!7 O d u w o (i FIRST FLOOR SECOND FLOOR • 0 ,,m�,� � Q £ymW�� o �mwp i u m o a KFioi 1/4" = 1i_oii - F102 1/4" Ott = 1'-O" oC p �=si= o S Q pC5 pct N / i(]V V C!, Z a SHEET DESCRIPTION FIRST FLOOR AND SECOND FLOOR 1 SHEET NUMBER �- 5 5 v .110 1/4"=1,0"F , ,. © UPONOR - CONFIDENTIAL F101