Loading...
PFI2019-00144 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT • • COMMUNITY DEVELOPMENT Permit#: PF12019 00144 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 05/06/2019 TIGARD Parcel: SEG2445 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: Level3 Communications(a Century Link Company) Project Description: SEG2445, 2469, 2496, 3035, 2495,2622. Associated with 7632 SW Durham Road, Tigard, OR 97224. Overlash 644'of 48'fiber to existing strand; build 2,003'of new 0.25 EHS Strand&48F fiber on existing poles; trench 6'&bore a total of 560.5'at a minimum of 36"below grade to place(1)-4" HDPE conduit and fiber. Owner: FEES Description Date Amount PFI Permit Fee 05/03/2019 $300.00 PHONE: Contractor: PHONE: FAX: Applicant: SCOTT MILLER 8021 SW CAPITOL HILL ROAD PORTLAND, OR 97219 PHONE: 503-754-7289 Total $300.00 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant Signature: 09(,(C vy. Issued By: ArTIA/10 Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PFI2019-00144 Type: Condition Name: Status: Severity: PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be reinstalled or replaced,with like kind of material. Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition,American Traffic Safety Services Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area. Traffic control devices, flag persons,etc., shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503-629-0111 (Tigard Police Dept.,Tualatin Fire&Rescue)and to 503-962-8140(Tri-Met) and 503-431-2345(Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08-TRAFFIC CONTROL ADVANCE WARNING Applied Notice Advance warning of traffic disruption shall be provided to the public by placement of an approved advance notification sign at each end of the construction area 72 hours(min.)before initiation of construction work. PFI_Utilities 09-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI_Utilities 10-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m. to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 11 -TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m. to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 12-TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 13-DRAINAGE CONTROL Applied Notice Drainage shall be controlled within the work site and shall not adversely affect adjacent private property, public property and the receiving system. The City may at any time order corrective action and suspension of work to accomplish effective drainage control. PFI_Utilities 14-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 15-UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 16-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 17-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities(roads, ditches, etc.)as may be necessary, as determined by the Inspector, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 19-PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity,the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert Phone#>,to establish a preconstruction meeting. PFI_Utilities 20-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. PFI_Utilities 21 -PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 22-DAILY INSPECTION REPORTS Applied Notice Applicant shall submit daily inspection reports, on a weekly basis,to the City's Inspector. PFI_Utilities 23-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 24-VALIDATION OF MATERIAL/CONSTRUCTION Applied Notice The City's Inspector may, at his discretion, require tests and or reports from the applicant to validate claims of material or construction adequacy/compliance. Such tests/reports shall be provided at the applicant's expense. PFI_Utilities 25-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have authority to resolve problems,take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing, of any/all assignment changes. PFI_Utilities 26-RIGHT OF ENTRY/EASEMENTS Applied Notice Applicant to obtain proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry or properly executed easements, shall be provided to the City. The City shall in no way be construed to be liable for the applicant's failure to obtain or provide for proof of right-of-entry or easements. PFI_Utilities 27-PRIVATE PROPERTY AGREEMENTS Applied Notice Provide the City a copy of an executed agreement[s]from the owner for each private property disturbed by construction activity. PFI_Utilities 28-AS-BUILT DRAWING Applied Notice 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). PFI_Utilities 31 -OTHER Applied Notice Other RECEIVED City ofTigard MAY 01 2019 INPUBLIC WORKS — ENGINEERING CITY OF TIGARD ' LANNIN�G/ENGINEERING Public Facility Improvement (PFI) Permit TIGARD TYPE OF WORK DESCRIPTION OF WORK(in the right-of-way) ❑TYPE 1—Franchise Utility Work Check one: El Utilities ❑Sidewalk/driveway approach 0 Streetimprovements performed by NWN, PGE Detailed description: Overlash 644'of 48F fiber to existing strand;build 2,003' and/or utility agency. of new 0.25"EHS strand&48F fiber on existing utility poles; trench 6'&bore a ❑TYPE 2—Sidewalk/Driveway/Sewer Work performed for the purpose of: total of 560.5'at a min. of 36"below grade to place(1)-4"HDPE conduit and fiber. • Sidewalk installation or repair. 7632 SW Durham Rd. Tigard, OR 97224 • Driveway approach installation Property�c ^ address/location l� s)' c�A �( and/or repair ��V Z� 1 j /TA) Zi `�J"055 2 i'1 ,2.62. • Sanitary sewer lateral installation and/or main line tap Level3 Communications(a CenturyLink company) El TYPE 3—Full scale Development Applicant: Work performed with Land use Address: 8021 SW Capitol Hill Rd approval which includes any of City/state: Portland, OR Zip: 97219 the following: Phone: 503.754.7289 Email: Scott.Miller4@CenturyLink.com • Subdivisions or Partitions Scott Miller 503.242.4144 • Street widening Contact name: Phone: • Mainline installation for Sanitary Contractor: C-2 Utility Contractors LLC sewer, Storm sewer, Tigard water and/or Tigard Water Service Area CCB#: 154786 Expiration: 3/19/21 Address: 11618 NE Sumner St, Suite A SUBMIT COMPLETED APPLICATION TO: City/state: Portland, OR Zip: 97220 City of Tigard Planning/Engineering Phone: 503.772.1878 Email:i: bheibergC 2utili tycom 13125 SW Hall Blvd. Contact name: Bruce Heiberg Phone: 503.772.1878 Tigard,OR 97223 Applications for"minor work in right-of-way" Engineer: K&B Technical Solutions only may be emailed to: g rowpermitsnaxigard-or.gov Address: PO BOX 2529 Clackamas,OR 97015 Fort STAFF tSF ONI.v City/state: Zip: 'rZ2© + Phone: 503.650.6041x202 Email: Jeff_Mettert@kbmail.net Case No.: ' Contact name: Jeff Mettert Application submittal fee(.007%of Engineer's Estimate) $ Estimated value of work is required(if over$5,000):$ Additional fees: $ _3ead (within the public right-of-way) Application accepted: By: St-- Date: S-1111 Is work related to a LAND-USE DECISION? ❑Yes ❑✓ No If so,please specify (MLP,SDR,SUB, etc.) case #: Applic f sewed: -5x/27 9 By Date: � Is work related to a BUILDING PERMIT? ❑Yes ❑✓ No App ca notified: ^ If so,please specify(BUILDING PERMIT)case#: By: Date: �.� �/} I:\ENG\PermitApplications\pfi_application Rev.10/16/2017 , sa'aae;.+ue=x+.� rwras »wa..ax. _. u,<;asa.-. s.. sncas- °acae_a• ..-.Murex.:. <. -ae.na -.arm. K..« u. :..,.e..: City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 1 of4 APPLICANTS NOTE: Person specified as"Applicant"shall be designated"Permittee"and shall provide financial assurance for work,if required by the city pursuant to TMC 15.041.140. * With the exception of a utility operating pursuant to a valid franchise with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner(s)must sign this application in the space provided or submit a written authorization with this application. Franchised Utilities are not required to obtain the owner's signature on the application BY SIGNING BELOW,THE APPLICANT(S) SHALL CERTIFY THAT: • The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject property. • If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. • All of the above statements and the statements in any plot plan,attachments,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denying the application. Jeff Mettert Digitally signed Date:2019.05 01y08 2y Jeff35=07'00' Jeff Mettert 5/01/1 9 Applicant/Authorized Agent's signature Print name Date SIGNATURES of each owner of the subject property, if required. Owner's signature Print name Date Owner's signature Print name Date Owner's signature Print name Date PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 2 of DEVELOPMENT ENGINEERING FEES FOR STAFF USE ONLY Public Facility Improvement(PFI)Permit: DETAILED SUBMITTAL APPLICATION FEE REQUIREMENTS Part 1: Required submittal fee$300.00(minimum) FRANCHISE UTILITY AND SIDEWALK/ PERMIT FEE DRIVEWAY AND UTILITY CONNECTIONS,ETC. Part 2: All non-water system improvements (work in the right of way) Engineer's estimate X 5%(less$300.00 minimum submittal fee) Sketch Engineer's estimate X 2%Plan Review (including information below) ❑ Dimensions WATER SYSTEM FEE ❑ Street Name Part 3: All public water system improvements ❑ Site Address Engineer's estimate X 12% FULL SCALE DEVELOPMENT PFI Permit Fee Exemptions: (Subdivisions/Partitions and Street Improvements) There will be no permit fee charged,or assurance required for the following types of work: Design Plans • Sidewalk repair(less than 20 lineal feet) (6 sets,24x36 or 22x34) • Relocate or replace mailbox ❑ Cover—Site,Vicinity,Abbreviation,Legend • Ditch cleaning that does not involve regrading. ❑ General Notes(City,Water,Sewer,etc.) • Weep hole repair ❑ Street(Plan,Profile) • Curb repair or replacement(less than 20 lineal feet) ❑ Water,Storm and Sanitary(Plan Profile) • Lawn sprinkler system installation or repair ❑ Water Quality Facilities • Street tree pruning or planting ❑ Grading • Planter strip landscape maintenance ❑ Landscaping/Tree Plan • Test wells ❑ Composite Utility Plan(Electrical,Phone,Gas, Storm,Sanitary,Water,Signage,Street Lights,etc) ❑ Details Note: A cash/bond assurance may be ❑ Traffic Sight Distance required per TMC 15.04.140. ❑ Signing and Striping (customer deposit) ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label(project land use name,revision and plan log block,dates and sheet numbers.) Additional Submittals (per Land Use conditions) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design(if applicable) ❑ Water Department Approval ❑ Engineer's Construction Estimate PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 3 of 4 / I — -_ / CONSTRUCTION NOTES : \` CONTINUE AERIAL OVERLASH(SW)IN »r.� 1. ALL WORK AREAS TO BE RESTORED TO LIKE OR ...—... ..._..._..._..._.� BETTER CONDITION. CITY OF TIGARD R/W AT EXISTING UTILITY POLE 2762. 2. ALL OTHER UTILITIES ARE BASED OFF EXISTING 2764 LOCATES OR UTILITY STRUCTURES. 7 t/ 16037 f \ 16045 / 3. R IS THE CONSTRUCTION CONTRACTORS 15995 \ / - RESPONSIBILITY TO CALL FOR LOCATES BEFORE � 1� DIGGING. I/ ti' a$ END AERIAL OVERLASH,BEGIN AERIAL/ 16100 LEGEND CONSTRUCTION(SW)IN CITY OF TIGARD p '\ /\ R/W AT EXISTING UTILITY POLE 1751. I NEW AERIAL FIBER A P .n IXISTING UTILITY POLE ®POLE ID 1 • pGF moi' -\ / b� 1751 """ PROPOSED RISER v +/ RAILROAD TRACKS '�����(������ y 16075 -\ RICHE OF WAY —gin — 1✓ • / \ PROPERTY UNE ,p �eF\ 16083 O' �\. p0 ry`,�, /(11752 16101 /14 -.\\„\I 16130 dr \ LS BEGIN AERIAL OVERLASH(N)IN t •• 0,`,'c_ ' CITY OF TIGARD R/W AT 1 Q`�� • EXISFING UTILRY POLE 4469. PGE \\;* / JQ Mil ( \ .� 2469 /' 16255 p( 7321 \ .—... • / MATCH POINT Al -SEE MATCH POINT A2 ON SHEET 2 /� 4 63 FOR CONTINUATION OF UNDERGROUND CONSTRUCTION. !/ PLACE RISER,END AERIAL CONSTRUCTION IN CITY OF F Z 16120 TIGARD R/W AT EXISTING UTILITY POLE 2918. p:46 8322 2918 / �� ,��,III...fff t rk '� / \ 16125 19192 ......, ,,,,,„.44,4,0 +// pGE 6323 \ i 2919 / \ Z L d/ \ 'g3 ,Ly 16160 6250 i 6 16325 \ 1 a As-euaT 1 1 REVISION i 1 CONTINUE AERIAL CONSTRUCTION05/0+/19 Mo J.M. ORIGINAL NO. DATE ENG DESIGN DRAFTING COMMENT EXISTING IN LIB OF TIGARD R/64. AT \��• EXISTING UTILf1Y POLE 9884. 1 Kfio..n.r.below. ) 34 NW /—� � ICalls ore you dig. ..,. ''–k \ lw I .ow ..1m.... Q IEVEL3 ENGINEER:Scott Raw-503.75'.7289 I}tr, ENGINEERING Mk:MS TecnicalSdYnr PROJECT NUMBER N468751-N.466751197651 LOCATION 7632 SW DURHAM RD 0 100' TIGARD.OR 97724 IlDRAWING NAME:NW SW CO*R3_Nwmlyonnl.a.9 SCALE: 1"=100' MEM I OF e BORE TO BE CONTINUOUS UNTIL DRIWNG IS /// / / / CONSTRUCTION NOTES COMPLETE AND TRACKED CONSTANTLY WITH LOCATION AND DEPTH MARKED EVERY 10 FT. r fff� 1. ALL WORK AREAS TO BE RESTORED TO LIKE OR I/I / ,p / 2 ALTTER CONDITION. 2. ALL OTHER UTILRIES ARE TURF OFF EXISTING � / / LOCATES OR UTILffY STRUCTURES. /} RR L''' 16255 / y ^ R • 3. D IS THE CONSTRUCTION CONTRACTORS / I RESPONSIBILITY TO CALL FOR LOCATES BEFORE t " / r ti(/3 FROM SFNTER -PLACE PROPOSNEW D L3048 VAULT VT OCATION OF R01 E PR DIGGING. or 15995 / I ! R '?OMR TRACKS` 27.42'(NW)OF PGE POLE 2919. MATCH POINT 81 -SEE MATCH POINT B2'ON SHEET � L � � 3 FOR CONTINUATION OF AERIAL CONSTRUCTION.END Si_ ENTER AND BEGIN UNDERGROUND -� LEGEND UNDERGROUND CONSTRUCTION IN CITY OF TIGAND R/W. 2500. . CONSTRUCTION IN PWRR R/W, AT RECEMNG PIT NEXT TO UTILITY POLE 2913. 25.00' DIRECTIONAL DRILL I/ / / / 10'SIN.BELOW t// BASE OF RAIL kI • MATCH POINT A2-SEE MATCH POINT Ai PROPOSED LVL3 VAULT o rn` "g END UNDERGROUND p ON SHEET 1 FOR CONTINUATION FROM • \• CONSTRUCTION IN AND / AERIAL CONSTRUCTION.BEGIN UNDERGROUND OWNER 3 o / COT PWRR t CONSTRUCTION IN CRY OF TIGARD R/W AT EXISTING UTILITY POLE ®POLE ID 2 4 EXISTING UTILITY POLE 2918. PROPOSED RISER m v 8 PCE 2913 go^o k p(� m A• PGE - ^� ICE "' BORE/RECEMNG PTT '__' ., /®�,I' 2914� �F 2918 2919 g RAILROAD TRACKS -I III I I t� , .a_ ma/1M Rn } . l� I`- 135—sP�'-.�N. RIGHT OF WAY —,;a-- _ � VT-01 >n o x. NW � E7''�- ... _• .. •-3048 EASEMENT oTM o - / __. �. CTL PROPERTY UNE —...—... —• - -—- - } / FACE OF PARBVE --i°� L �17}' - a -—-—-—27A2—- —- EDGE OF PAVEMENT m 1 SW DURHAM RD—-— SW DURHAM RD—- ��� � EXISTING SIDEWALK 4n - PWRR rEPOBf. EXISTING STORM DRAIN 3E 34,49 t EXISTING STORM MANHOLEMR.. ® R" "`' --• R. '-'"' RW %�'—o`g-�`• EXISTING STORM INLET 0 BORE AND PLACE 135'OF(1)-4P CONDUIT FROM o VAULT VT-01 TO POLE 2918 NM TI£CONDUIT EXISTING SEWER LI n� 'I THAT CROS THE RAIROAD TRACKS. EXISTING SEWER MANHOLE MR `°`—`°`---------......,,, EXISTING WATER 4n+ ,n *n *n :n " EXISTING GAS gm n ,,, 4M VW R/0, .n ,,,,,_,,Al�^.„ h, '14/. / V ti/66 FROM CENT R -4.SCHEDULE �A RACKS j /r 80HDEPE 2913 1 UNDER FTHERAILROAD FROMVAULT UOF ) 11 TO POLE / , ANDPLACE365' i Q // 16325 1 7520 i ,,..7...................„. ..............„,...., ................... ................, I 3 1 AS-BUILT 6 1 05/01/19 110 J.Y. °RONAL NO. DATE ENC DESIGN DRAFTING REASUR I 1 CDMMEN7 KraCa1N74b9181P. CBR\e.ra.you ay OY LEVEL 3 ENGINEER:Scott Mo-503.7543298 ENGINEERING FIRM:1L&B Technical SoL4lar PROJECT NUMBER N466751-NA68751(97651 LOCATION:7632 SW DURHAM RD 0 10' 20' 30' 40' TIGARD,OR 97224 DRAWING NAME:7632 SWHA R0_14b6791_P.,,taq SCALE: 1'=40' NNEET. 2 OF 4 - / 7882 7864 7844 7952 7826 7796 � 7764 . CONSTRUCTION NOTES 1 � �- —... 7794 /," \/T Opt,..„. ... 15996 ...—...15970.. 1. ALL WORK AREAS TO BE RESTORED TO LIKE OR • BETTER CONDITON. ns0 �.. I 16002 SW DURHAW RD 7736 7724 1 E—. . 2. ALL OTHER UTILITIES ARE BASED OFF EXISTING .p• 7718 I 16018 LOCATES OR UTILITY STRUCTURES. --977 "„' 9i.—'_" 0' 7706 K_... 3. IT IS THE CONSTRUCTION CONTRACTORS 7704 I •16032 / R SPONSIM �TO CALL FOR LOCATES BEFORE Yr '4?P• ,q 16050 t / MATCH POINT Cl -SEE MATCH POINT C2 ON SHEET 4 : 16060 FOR E UATK)N OF UNDERGROUND CONSTRUCTION. 16068 LEGEND PLACE RISER,END AERIAL CONSTRUCHON IN CITY OF / TIGARD R/W AT EXISTING UTILITY POLE 2908. PEp 4� NEW AERIAL FIBER A DIRECTIONAL DRILL ..) 7910 N44,..' X70' / 15995 EXISTING UTILDY POLE ®POLE ID \\ I �� / PROPOSED RISER RIGHT OF WAY i 9POE1 DOSING LINE ---...— :y SDNG BUILDING '..\\\\\\\N\\X\,.\`�" 1� J 7632 ��� Sy, 04, Hp :v / ti J 2912 J/ �N / �- ,ts�. 1a�p F • �� i' / •� 5� ‹.... / �/ � 2913 MATCH POINT B2-SEE MATCH POINT 81 ON SHEET 2 FOR CONTINUATION FROM UNDERGROUND CONSTRUCTION.PLACEp(� RISER,RESUME AERIAL CONSTRUCTION IN CITY OF TIGARD 2914 RAV AT DUSTING UTILITY POLE 2913. .—._i.. -1 I 7520 I1/771 � 16325 I:00 I ' -.u•rm,e.nn A5—BULLY NI MOS/Ot/1B MO J.M. Mum. 7.77:7ZS# 0. D M ENG DESIGN dtA7DNC COMMENT Snow whets below. Call before you 44 LQ7 LEVEL 3ENGINEER:Scott M r-503.154.7289 ENG9IEERBNG FRM:KGB TaWNNA SO9AO E PROJECT NUMBER:N4687514N.468751(9165)_ LOCATION:1632 SW DURHAM RD O 50' 100' TIGARD.OR 9122 DRAWING NAME:26323w1:01.3122_44.4223123.04•41 SCALE:I•-100' 9E 3 GF 4 �°\� \en\s '--4.., N. / / CONSTRUCTION NOTES "� 1. ALL WORK AREAS TO BE RESTORED TO LIKE OR �,4 \5 s a\ \ \ 77� / / BETTER CONDISON. \\,� ^' MATCH POINT C2-SEE MATCH POINT Cl ON SHEET 3� 2. ALL OTHER UTILITIES ARE BASED OFF EXISTING �, �� FOR CONTINUATION FROM AERIAL CONSTRUCTION.BEGIN . / 7736 / / LOCATES OR UTILITY STRUCTURES. UNDERGROUND CONSTRUCTION IN CITY OF TICNiD R/W 3. IT IS THE CONSTRUCTION CONTRACTORS _ \ AT EXISTING UTILITY POLE 2908., \_\ .- \s RESPONSIBILITY TO CALL FOR LOCATES BEFORE \_ \mow\5 / / DIGGING. \ \.§. M\s \ / -' 7724 o / LEGEND W OURHAb R0\ \ �w s, o �\ `�.. \,4\\11. '.. • / 7718 \ TRENCH - w\+ FROM POLE 2908,TRENCH 6'(NW)AND 4 \ DIRECTIONAL DRILL —-- . BORE 69.5'(SW)TO THE EDGE OF THE ��' / NAME �„� R/W,ALL AT A MINIMUM OF 36'BELOW gi / PROPOSED LVL3 VAULT EV TYPE GRADE,AND PLACE OF(1)-4'CONDUIT ♦ 4P,,," OWNER �., c''' 4. EXISTING UTILITY POLE ® ID \,\ `\ i�, t." PROPOSED RISER S.� 4' �\ \ BORE/RECEMNG PIT L_ Mn \• .\4e4Qi / \ R/W ALIGNMENT - '' ® %Y RIGHT OF WAY --.Fh,,__— PLACE NEW 3048 VAULT VT-02 10'FROM,, o QS�j w TELCO MANHOLE '� \ EASEMENT FOC(APPROX.0.5'INSIDE R/W). P. / �� \ \ \ PROPERTY LINE —...—...— END UNDERGROUND CONSTRUCTION IN . \yq, 4 AND EXIT CITY OF TIGARD R/W. tr...„............... '; FACE OF CURB m EDGE OF PAVEMENT � ,\. EXISTING SIDEWALK ----.n \ EXISTING STORM DRAIN —44 VT-02 8 .� \\�,\ EXISTING STORM INLET O �, 0 . ti 8 �'§, EXISTING WATER w TBEXISTING TELCO PEDEST EEXISTING TELCO PEDESTAL/ C // 4 7Y TELCO/R 9 O h mail `W \ 7800 / oo S• x • O 3 . .� 7632 811 O srw =..g.,w.w„ e AS-SUIT 811 G REVISION I I Na 05/01/10 NO J.Y. ORIGIWL ---IP OATS ENG DESIGN DRIFTING 1COYYEYT Know wnanbelow. �(3 Call7.Ibelow da 1 LEO.3 ENGINEER:S.AI06w-503.754.7289 ENGINEERING FIRM:KGB Technical S&Allar PROJECT NUMBER:N468751.N.468751(97651 LOCATION:7632 SW DURHAM RD o 20' TIGARD,OR 97224 DRAWMS NAME:7ee2 Sw morn a rwenat_Rw.S.0 SCALE: 1'-20' MEET. 4 OF 4 Page 120 2011 Edition Work in the Center of an Intersection Diagram 630 Diagram 630 covers work within an intersection of two-way streets. Movement of traffic through the intersection is regulated by existing traffic control only. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3— Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. For multi-lane approaches, merge traffic into one lane in advance of the intersection. 4. For high speed or high traffic volume operations, consider using flaggers to control traffic. 5. When the posted speed is 40 mph or less and work is in place for less than 15 minutes, cones and signs are not required. Sign Spacing and Buffer Lengths(feet) Posted Spadng Between Signs "Buffer" Speed A 8 C Space 20 50 25 100 100 100 75 30 100 35 125 350 350 350 40 150 45 180 50 500 500 500 210 55 250 60 285 65 700 700 700 325 70 365 Chapter 5 September 2016 2011 Edition Page 121 Work in the Center of an Intersection Diagram 630 1 t ROAD WORK AHEAD 1 ROAD A WORK 't AHEAD c C . \ E ,t 7 ;(\. +u2 + A 10 ft.min. a, V» :� • • . 0 m •• • • 10 ft.min.< /41 if o A - L/2-0-12 • t • o u2 P ROAD ,t • 3 WORK AHEAD r ROAD V WORK AHEAD 1 t September 2016 Chapter 5 Page 106 2011 Edition Diversion into a Continuous Left Turn Lane Diagram 430 Diagram 430 shows work in the travel lane(s) next to a continuous two-way left turn lane with one direction of traffic diverted into the continuous two-way left turn lane. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3— Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. When two or more travel lanes are reduced to a single lane before the diversion, each lane shall be closed separately. Layout traffic control according to ODOT Standard Drawing TM 852 for 5-lane sections. 4. A shifting taper(L/2) may be added in the diverted traffic direction across the continuous two-way left turn lane (as shown). This option is recommended when the speed is 45 mph or greater. Sign Spacing and Buffer Lengths(feet) Posted Spacing Between Signs "Buffer" Speed A B C Space 20 50 25 100 100 100 75 30 100 35 125 350 350 350 40 150 45 180 50 500 500 500 210 55 250 60 285 65 700 700 700 325 70 365 Chapter 5 September 2016 2011 Edition Page 107 Diversion into a Continuous Left Turn Lane Diagram 430 //ROAD WORK ; B 11y1t /c'EnrrER UWE CLOSED • AHE A II • L/2 I • . • Buffer • 1 Protection Vehicle w/TMA(both Optional) • See Chapter 4 nu n • __ Buffer 11 1 • • • L/2 I • • 1 • • • U2 I • I A •. I t B �, I ROAD • WORK AHEAD September 2016 Chapter 5