Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PFI2019-00165
CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT • COMMUNITY DEVELOPMENT Permit#: PF12019-00165 Date Issued: 05/29/2019 T I G A R D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Parcel: SEG775 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: PGE Project Description: SEG 775/ 11740 SW 72nd Ave. New service and lighting. PGE Job#M2619695&M2372397 Owner: FEES Description Date Amount PHONE: Contractor: PHONE: FAX: Applicant: RICO SOLIS 10800 SW AVERY STREET TUALATIN, OR 97062 PHONE: 503-612-2943 Total $0.00 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant /( f7PL17 a �� I Signature: �l1 Issued By: Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PFI2019-00165 Type: Condition Name: Status: Severity: PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law, the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be reinstalled or replaced,with like kind of material. Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition, American Traffic Safety Services Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OUCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area. Traffic control devices, flag persons, etc., shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time, without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503-629-0111 (Tigard Police Dept., Tualatin Fire&Rescue)and to 503-962-8140(Tri-Met) and 503-431-2345(Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08-TRAFFIC CONTROL ADVANCE WARNING Applied Notice Advance warning of traffic disruption shall be provided to the public by placement of an approved advance notification sign at each end of the construction area 72 hours(min.)before initiation of construction work. PFI_Utilities 09-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI_Utilities 10-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m. to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 11 -TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m. to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 12-TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 13-DRAINAGE CONTROL Applied Notice Drainage shall be controlled within the work site and shall not adversely affect adjacent private property, public property and the receiving system. The City may at any time order corrective action and suspension of work to accomplish effective drainage control. PFI_Utilities 14-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 15-UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 16-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 17-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities(roads, ditches, etc.)as may be necessary, as determined by the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 19-PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity, the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert Phone#>, to establish a preconstruction meeting. PFI_Utilities 20-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24) hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. PFI_Utilities 21 -PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 22-DAILY INSPECTION REPORTS Applied Notice Applicant shall submit daily inspection reports, on a weekly basis, to the City's Inspector. PFI_Utilities 23-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 24-VALIDATION OF MATERIAL/CONSTRUCTION Applied Notice The City's Inspector may, at his discretion, require tests and or reports from the applicant to validate claims of material or construction adequacy/compliance. Such tests/reports shall be provided at the applicant's expense. PFI_Utilities 25-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have authority to resolve problems, take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing, of any/all assignment changes. PFI_Utilities 26-RIGHT OF ENTRY/EASEMENTS Applied Notice Applicant to obtain proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry or properly executed easements, shall be provided to the City. The City shall in no way be construed to be liable for the applicant's failure to obtain or provide for proof of right-of-entry or easements. PFI_Utilities 27-PRIVATE PROPERTY AGREEMENTS Applied Notice Provide the City a copy of an executed agreement[s]from the owner for each private property disturbed by construction activity. PFI_Utilities 28-AS-BUILT DRAWING Applied Notice 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). PFI_Utilities 31 -OTHER Applied Notice Other RECEIVED City of Tigard MAY 2 9 2019 PFI#: 201I— DDICOS 1111 :11. ENGINEERING DEPARTMENT CITY OF TIGARD Public Facilities Ni 5vement (PFI) Permit PROJECT INFORMATION TYPE OF WORK Project name: PGE Job # M2619695 and M2372397 8 TYPE 1-Franchise Utility Work Brief description of project: performed by NWN,PGH or utility agency New Service and Lighting ❑ TYPE 2-KM/Sidewalk/Driveway/Sewer Work performed for the purpose of: • Sidewalk installation or repair • Driveway approach installation and repair SITE INFORMATION • Sanitary sewer lateral installation and Location (address if available): 11740 SW 72nd Ave main line tap D TYPE 3-Full Scale Development Work S 1.1 Cperformed with land use approval which includes any of the following: • Subdivisions or Partitions APPLICANT INFORMATION • Street widening PGE [Submitted by Marsha Prichard] • Mainline installation for sanitary ewer, Name: storm sewer, Tigard water, and Tigard Mailing address: 10800 SW Avery Street water service area City/State: Tualatin, OR "Lip: 97062 ❑ TYPE 4-Small Cell Technology Phone: 503-612-2943 El TYPE 5-Tigard Triangle Email: preregcoord@pgn.comphone: 503-464-7777 NOTE: Type 1 and 2 applications may be Contact name: Rico Solis - Steve Hursh emailed to rowpennitsltigard-or.gov. Phone: 503-672-5417 - 503-672-5409 Email: preregcoord@pgn.com CONTRACTOR INFORMATION 0 Same as applicant Name: CCB Number: Mailing address: City/State: Zip: Phone: Email: ENGINEER INFORMATION Name: Mailing address: City/State: Zip: Phone: Email: ADDITIONAL INFORMATION Estimated value of work is required(if over$5,000):$ (within the public right-of-way) Is work related to a LAND USE DEC.ISION? DYes No Case number: City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 1 of 4 APPLICANTS NOTE: Person specified as"Applicant" shall be designated"Permittee"and shall provide financial assurance for work,if required by the city pursuant to TMC 15.04.140. * With the exception of a utility operating pursuant to a valid franchise or license with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner must sign this application in the space provided or submit a written authorization with this application. Franchised or Licensed Utilities are not required to obtain the owner's signature on the application. I, the applicant, certify that: • To the best of my knowledge,all the information provided within this application package is complete and accurate. • The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject property. • If the application is granted, I will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. Marsha Prichard for Project Managers 5/29/19 Applicant's or authorized agent's signature Print name Date Property owner's signature (if required) Print name Date STAFF USE ONLY Case No: PF WIqHNU5 Permit fee:_—' Received by: Dater2fi 19 Approved by: ray Btt � Date: �'1(� Gr 2 9 Z Di 9 Notified by: ' Date '‘ � City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 2 of 4 RECEIVED MAY 29 2019 APPLICANTS CITY OF TIGARC PLANNING/ENGINEERING NOTE: Person specified as"Applicant"shall be designated"Permittee"and shall provide financia assurance for work,if required by the city pursuant to TMC 15.04.140. * With the exception of a utility operating pursuant to a valid franchise or license with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner must sign this application in the space provided or submit a written authorization with this application. Franchised or Licensed Utilities are not required to obtain the owner's signature on the application. I,the applicant, certify that: • To the best of my knowledge,all the information provided within this application package is complete and accurate. • The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject property. • If the application is granted,I will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. Marsha Prichard DigitallysignedbytrialPt oaor.d Marsha Prichard for Project Managers 5/29/19 Date:2019.05.29 16:47:11-07'00' � g Applicant's or authorized agent's signature Print name Date Property owner's signature (if required) Print name Date STAFF USE ONLY Case No: Permit fee: Received by: Date: Approved by: Date: Notified by: Date: City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 2 of 4 DEVELOPMENT ENGINEERING FEES Public Facility Improvement(PFI) Permit: INITIAL PFI PERMIT FEE Part 1: Required submittal fee is 10%of the Net PFI Permit Fee.See below for calculations.Minimum of$300. NET PFI PERMIT FEE Part 2: All non-water system improvements engineer's estimate X 7%(less the initial PFI Permit Fee). WATER LINE CONSTRUCTION FEE Part 3: All public water system improvements engineer's estimate X 12%. FOR STAFF USE ONLY FOR STAFF USE ONLY TYPE 4: SMALL WIRELESS FACILITY TYPE 1—3:DETAILED SUBMITTAL CHECKLIST REQUIREMENTS Does applicant have a right-of-way license? ❑Yes ❑No TYPE 1 AND TYPE 2-Must include a sketch showing: Under the wireless facilities standards,is the proposal ❑ Dimensions considered?(check all that apply): ❑ Small Cell ❑Macro ❑ Street Name ❑ Site Address How many install sites are proposed as part of this permit application? TYPE 3-Must provide 4 sets of plans (sized 24 x 36 or 22 x 34) and an electronic version of all submittal The proposed equipment is located on which of the following: items. The plans must that include: ❑Public Right-of-Way ❑Private Property ❑ Cover—Site,Vicinity,Abbreviation,Legend If equipment is to be located on private property,describe the ❑ General Notes (Citi,Water,Sewer,etc.) type&use: ❑ Street(Plan,Profile) ❑ Water,Storm and Sanitary (Plan Profile) ❑ Water Quality Facilities ❑ Grading ❑ Landscaping/'Tree Plan ❑ Composite Utility Plan(Electrical,Phone,Gas, Storm, Sanitary,Wates;Signage,Street Lights,etc) ❑ Details • Traffic Sight Distance ❑ Signing and Striping ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label (project land use name,revision and plan. log block,dates and sheet numbers.) ❑ Engineer's Construction Estimate Additional Submittals (per land use conditions,if applicable) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design ❑ Water Provider Approval City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 3 of 4 r SIV " N1- " SI Edge of Pavement ",— Ditch --Pi- Streetlight —•i•—•s•—•—• -r—•— Rain Drain a *#.4W ® I ' ' ,'.,r.a I I T-1761'ogt cf'Sej�wgrriine" I r gl al Existing House 1 I I ''' v� j Existing I i u Driveway t_l 31 I 01 1 al I TI o, l ,� I 21 � iio° D I Existing Shop S \ • Powerpole I I o I o I �.[ I' 95! — — — I — Ir:5—-—-— Fropert Line Fire Hydrant(FH) I I ( I Scale: i"=30' l I I I I I i I TYPE 1 AND TYPE 2: MINIUM SKETCH REQUIREMENTS (Put N/A if not applicable) North arrow Property lines &dimensions Existing utilities locations (sewer, storm,water) Street& street names All existing structures Proposed work Existing curb or edge of pavement Utility& street light poles Existing S/W or D/W apron Slope of property Trees City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 4 of 4 NEW PGE FACILITIES TO BE INSTALLED • DO WITH TDSWD.WO#2420237 THINK (UNLESS OTHERWISE SPECIFIED) Q FAULT INDICATOR ABC 500 SAFETY O5106-PGE PAD MOUNT VAULT, RIRW a' PROVIDED&INSTALLED BY CUSTOMER INSTALL 3-02 AL-TX JET PRIMARY IN I-I"PVC CONDUIT,PROVIDED&INSTALLED BY CUSTOMER 3 e-------------- 7INSTALL 1-0350 AL-OS SECONDARY IN 2 OF 4-3"PVC CONDUIT • t9fi' I------1-2'-.7-:-.77.-Z-:-.7--7-:.-r. P0-109 A VT98 � O PROVIDED&INSTALLED BY CUSTOMER INSTALL 1-#350 AL-0%SECONDARY IN 3 OP 5-3"PVC CONDUIT ® ® pD-109 OB PROVIDED&INSTALLED BY CUSTOMER N9TKL' P ABG O SOOKVA Y 0 OB iA2°wV.s20008V.3v,OW CONSTRUCTION NOTES: CMDEV R RESIDENf4LL COMMERCIAL 7L CUSTOMER DO .PONS Fat ALL'RENCK CONDUIT,VAULT,FADS AND 0000 O®O®® :OM OLL�,a 7 tOruLED WITH,D NINES D.IN,COVER AT T«OF CONDOM Q BACK BACKINC CONDUCTORS TO RE KO]wm fIN DR"SCHEDULE.a ELECTRICAL GUDE, Q INSTALL�tiS IIx comm. a5n s-a�]M<L aOWuniN ] TIE SRF DUIT N MMI OAF CO DVIS�R¢WIRFD.wNTAN/VINIGL INC".AND al NORRONTAL INCHES OFFEANES W WS AND OTRILIESMI MOWS Ia0V I20,2010 SAALE? TEEE . ALL ELBOWS LARGER DIAN 4 NCN TO 00 INCH DAM ROD L^ 1000PMP IMOAMP APPRO.,.FINILGLASS WAD AM REOUMFD FOR RLINS , w OF INF RNs NC SOIEDUIe H .1%ply :114 MR TOTAL RENDS N ANY COND.NON 170 MOMS d I 26,5450 AK 29,3190 AK ON 7,676.DN.,REUL.EIOD 38-100A NET METERS 8-2008 318 METERS dl SCHEDULE N PVC W111• iC 090KW1 (288RW1 CONNECTION a1MEMENn OF PODOPP SPEECRNCAAN IPN IC1RroGfA ON we oNOM HOPS MAO ADET POE T EMaA DGERI.EON SANK rt•SCNS MR N.SD. ArVA.RIM.�E�NrNn�MANIMN ALL O ACE T OF !OPE RDE D a Eo�n.HINSTALur W1 OE NINO.PR... b..POE,WALWANSLeOR LAS OPEro RF UAND 4 s rtn CODRANT. AIUSIWIE FIISLMANS.L AWN Eo FEET ANY NIN CLEARANCEFEET A OWEN.AREA ALWAYS MAINTAIN V P. IS FRONT Of ML TRANSFORMERS. SO RHT TNF Wr D]CATED IN DE M AND GPDAF«MnIBOE«.NDDII%rOREQUIRED e�A D N vAo ws Raurm N oErAR ARov°TM P. t=r�ww % SAM POSTS AROUND nwarawEO MAT ARE 10,000 t' % ca,... .r. !SME AT DMD.LOW R NCC GM52L RASE AND n. W. a'ro vSTILII L� R.ALL SMAA VAULTS S ro VAULT END LOWER RNocxolm N'"M V R�e+.P".]rwl. 1s�usLsucN�sReromU� pERM-A-Quem. r rM "' v.POE TO RF MS ALL AND VAULT ALL IdAV NS,AW FAD RdMILATDNs i r`-' Y T'�^'-sem MOW MCRML.0 NEw VAULT a PAD LMATnNs ro RE NftD vECNT, i iw, w..F I.�.,0,70ALFR RENTIIMA.NF W.6 SPtt cE E FMCIRIGLL SFNCE RW«EAYNT6 WOR FOR FNT,.DETAILS eewneMENrs.uNR ro meoemLRRemeO%aurnenFaemr cm Rs" O.w�'F R DEDON D BASED ON STANDARD NDnGROUND EQUIPMENT.MN-STANDARD 10 ) W.4o.sr.s ma o. me comsat raIAPMRur MAY s AN«rDN•T•N ADDITIpIu COSI TO 1 a-we.T, Fr 0NE uD E )7,f xnw nr-mD]sM.vvulrou[R AI+O 3O® ®O 8909N5RIGHT-OF-WAYOMTHE LOCAL NOTICE: CONTACTSERVICE „..,..=„r OORDINATOR .PIMW APERMIj FROM THE JLRa.SDICTION 19 REQUIRED0BEFORE ANS '''',7..'-')) mets.,9RNenWN woe GALL NI WON MO DID ni OO OO Rltl CWORK RR NTRACHE TORS ADCONTRACTORS PERFORMED.ME OTHE EPEPROVEnIafIIVKF COORDINATORm oeEooH uw CONTRACTOR88NT-ORWE E 01,PGESPECIAL APPRO ANY DEVIA710N FROM THIS DESIGN MU AGREEMENTSVATIPOK WaIBEALLOWEDTO RK UNDER HOURS ElL1IT.I SDS-SaS-6>oc OP WO-s.a-.,.„,UEMI �PM�oSa+L*«MP I BE APPROVED BY PGE PROTECT MANAGETMECONTRACTOR MUST NOTIFY THE LOCAL JURISDICTION AB HOURS ..Ww. n \ / BEFOREMORIL IS TO BERN.A COPY OF THE PERMTPAIST BE ON SITE I,eler. WEST OMRoe.'TR00 • • PGE CONSTRUCTION DRAWING 5106—PGE VAULT NOTES, FIBS 1110.0PEN 5106 PGE VAULT AS—BUILT VERIFICATION & NESC VIOLATIONS CORRECTED 1 VAULTS TO BE (09CAL1 This document accurately represents FIELD Construction. 8:8• $106-T-2436P-TRANS2-PGE SET AT LOCATIONS 5106-T-3-332NS-PGE LID \ 6� r� foreman: Date: APPROVED BY PGE. •'TO VA" .I�� VT-7 B•1008 S / 1T-2" 2.TOP OF UD TO // General Foreman: Date: �`- BE SET AT FINAL `� , NOTES: 'circ GRADE, 1.VAULTS TO BE (Signature only required for field construction changes.) ¢o' <O APPROVED BY PGE. 2-e-TO 5;,. ,aa SET AT LOCATIONS SDP/SA/NG REVIEW: I ASBUILT BY DESIGNER: METER J '.42,..:`,".... O ` P APPROVED BY PGE. i y .�� J F 3.DO NOT CROSS BAYLOR IT 'gp. DATE: SCALE ACCOUNT: AWO. OB NO. r.%:'',.. ,.- PVC BETWEEN z.roP of uD ro T/M9 NTS 1070001 ' 1000004597 052372397 BE SET AT FINAL > ,'�yJ �ti Y� VAULTS. GRADE, T17LE �� ...",44.7' I.INSTALL 500 LB / APPROVED BY POE. 72ND AVENUE PROPERTY LLC n 98� . (MIN)TEST PULL- 3.DO NOT CROSS 1 RING IN EACH PVC. PVC BETWEEN CBFCUIT SIZE CF vnuLn. ` WEST PORTLAND-72ND 11x17 PD-109 �/ • 1 INSTALL 500 LB �GE LOCAiON WEST v • / •• (MIN)TEST PULL- ` 11720 SW 72ND AVE,TIGARD �4ra. / STRING IN EACH PVC. 1JJ �O0�F e • PROVIDE/000A 120'108 SRVC TO 38 APTS AND 1200A 120500 FOR HOUSE/FUTURE RETAIL Sip_ . • BASE/MIDDLE#5106�/M-PGE M • TRANSFORMER COUNTY SECTION(S) WORK WITH 5900T i'i .I LID 5106-T-3332NS-PGE BEAVERTON WILSONVILLE 01360 I OF T C, • 314"MINUS a"i0 11-92 LINE CREW CENTER DESIGN BY PHONE(5031 DRAWN BY EAST CRUSHED ROCK 2-6'TO ND SW 15510« STEVE HURSH 503-672-5409 J CESAR DEL ROSARIO 6"DEEP(MIN) ' • N-92 BEAVERTON,OR 97006 0 PORTLAND GENERAL ELECTRIC CO.-ALL RIGHTS RESERVED II LIGHTING LEGEND CREW TO RN, I.IOURE ON PL X6690 WITH SBR LED i, RENACE FVFUREXISTING INSTALL F. "IES REMOV C ILITIES MAST ARM WITH 6'MA 130'MNI CORNER!240V Z INSTALL 1-4"POLE CONDUIT UNIT ...... • 1-3'10440 PVC CONDUIT FOR FUTURE STUB SPARE --)R 4490 WI 18"BRACKETS `� VOL COO INSTALL 1-1/0 AL-TX ST LT CIRCUIT IN 1-3"SCH40 PVC TX1D A55EBMOa INSTALL 1-3"PALE CONDUIT UNIT CONDUIT.PROVIDED&INSTALLED BY CUSTOMER I INSTALL 1410 CU-TX ST LT CIRCUIT IN 1-1'SCH40 PVC _ CONDUIT.PROVIDED&INSTALLED BY CUSTOMER W 1v ri ` A B•� INSTALL 88W LED LEOTEK ON 36'2PC FIBERGLASS GRAY ' Y�J-,�S POLE WITH 6'MAST ARM.(30'MOUNTING HEIGHT).SET 2' 0 0 IOp.T;n, sS FP-FC.CONNECT AT 240 VOLTS dAmn N9u A �I 4 GONN®a0u PAD I, za.. .OW I HA- 1 CREW TO ENERGIZE EXISTING 49W LED LEOTEK FIXTURE RESmEMIu6 1 ON EXISTING DIST POLE 902103 WITH EXISTING 1 V MAST 1yy1A'' 2 PIECE FIBERGLASS(COMPOSITE)POLE CONNECT@NGV �� ©OO� 14L-6690 I -6690 n n,P 1.I '574'.Nn ) CREW TO REPLACE EXISTING 49W LED FIXTURE ON e' tom"a �L XMAST WITH BREW LED LEOTEK GRAY FIXTURE ON e'MA < A« X« se."I ce�e�n 11111 I I T (30'Mlp CONNECT @2401 u5 RCA:.+M a»..wo7g,"=',.= Q CUSTOMER INSTALLED 1730 STREETLIGHT JUNCTION BOX t00GtnSP uu. w ''ll Ifwd. v REMOVE 190'X6 TX OH ST LT FROM PL 1193 TO PITH 2103 %W WOMAIP N7.. •iIi• G,a, REMOVE 49W LED LEOTEK FIXTURE WITH 9'MAST ARM ON aEAr. 10208 I T, r�e0M DIST POLE 99909/ASSET!99M09 A A AFC INSTALL 30AMP FUSES IN SECONDARY PEDESTALS I OR SECONDARY VAULTS(WHICHEVER IS ST LT POINT _.- ,— OF ATTACHMENT) FOR EACH STREET LIGHT PERT&D CONSTRUCTION STANDARD LC-11550 _— IFaR' amiss ~ PGE TO PROVIDE BOTTOM PIECE OF POLE FOR CUSTOMER TO INSTALL AT THE SAME TIME AS THE CONDUIT. Q1 NRB MTI BOTTOM PIECE POLE INSTALLATION ANY DEVIATION FROM THIS DESIGN MUST N 190 'I0'"'- CUSTOMER TO REPLACE EXISTING 1324 VT-95 Tem*9a«A P.m Nu*/a Ia. BE APPROVED BY PGE PROJECT MANAGER TOA 1730 VT. aY R�n mot md N I 35 CUSTOMER TO CALL PGE SERVICE DESK 0 wrc F°"'A!""- � ) 503-323.6700,TO SCHEDULE CREW STAND BY 2 PGR 0-�S'uOrmftI ern Pe.,,, I WHILE PLUMBING INTO EXISTING VT 95 des N s70 mr ;,eFe.to E Y„s _ CONSTRUCTION NOTES: sLcsT • I t.CUSTOMER TO PROVIDE ALL TRENCHING,BACKFILLMG, ONDUIT,ELBOWS.JUNCTION BOXES,VAULTS AND PADS JOINT USE TRENCH WITH GAS TRENCH TO. A 25 JUNCTION BOX INSTALLATIONS BRILHES DEEP ANp 301NLHES WIDE.MEASURED FROM TINA'f.RADE. DD WIN ® __ _ FOR STREET LIGHTING 2. PGE STANDBY CREW IS REQUIRED FOR OPENING ALL ENERGIZED PGE VAULTS 27ORN) -134 INTACT PGE FOR APPROVED MANUFACTURERS JUNCTIONBOXESANDEOUIPMENTFACRRIESINCUDINGCONNECnONORINStALL1nON H -- - F SCHEDULE TS AND PULL STIR NGS.CA L SERMEE LOORDINAT ON AT 50}3218)00 • • " FINAL GRADE F WAD SURFACE(FLUSH TOOSCHEDULE A PGE STANDBY CREW. -TSS --- "- 3 ALL PGE CONDUCTORS TO BE INSTALLED IN GRAY(SCHEDULE 40 ELECTRICAL D-133 - --I 13",631;IF OR PG ETOEO DETERMRIE THES ANDNNlR�.9LER OOOLSONDUR SO°REOUIREDST)• L■■■ OBI MAINTAIN 12 VERTICAL MCHES AND 24 HORIZONTAL INCHES CLEARANCE BETWEEN • h't FINAL GRADE P SOFT�� "MP I SPOE URFACE GAS AND OTHER ITLITIE9 ALL ELBOWS 41NCH 8 SMPIIER TO BE JB INCH RADIUS A jypGE RIGID STEEL OR PGE APPROVED FIBERGLASS BENDS ARE REQUIREQ FOR RUNS OF I 51 FEET OR LONGER OR FOR ANY LENGTH RUN WITH MORE CANS FISOF ETO $ I Mom*Rem. 151 FEET PVC LONGER. FOR ANY LENGTH RONWBLEFOR RUNS OF150 DEGREES LESSTHE MA kalEOTALBENOS INANY CONDMTRUN IS 2)O DEGREES ALL ENDS MUST BE FACTORY MADE.REFER TO LETTER OF RESPONSIBILITY FOR \/ i0 Go SVTot�N ST ETFvaµOBOE FURTHER DETAILS _ , A CONCRETE FOOTINGS NEED TO BE INSTALLED WITH TOP OF BASE - YOn 9-WC SCH MI RILISH TO CURBISIDEWALK. _-� •HLII OBEY 5 CUSTOMER RESPONSIBLE FOR ROAD CROSSINGS ALL CROSSINGS MUSTEMEND ELECTR ULGRAOE F uAAss FROM PROPERTY UNE TO PROPERTY MNE CROSSINGS TO BE 481NCIIEB DEEP. roEtERi,T.4.YPGO s'OR MX=ISO. 18. E7GREES MEASURED FROM FINAL GRADE. OR MORE BENDS 8.DIRECTIONAL BORING REQUIREMENTS:BLACK HOPE(HIGH DENSITY POLYETHYLEN DUCT NM FEW YI MIUAPLN lEalL REQUIRCMI NPROWC TI2AmITIONNATVETOEHDTGEDULTRHADPRTOSHAELMEEMT TH IOAL wOaiaRIFM oP HELI ANDE BOX REWIREMEMS OF PGE SPEC FICAT ON LC20515 U BE Bl LE ON REOU ST FROM PGE PROJECT MANAGERS.FOR SAFETY REASONS THE DUCT SHALL BE BLACK WITH THREEFXI EQUALLY SPACE HOPEPSTRIPES IWMCH ISASPECIFlLATIONREWXREIS LURE'TEST OF IPE IS REQUIRED AFTER INSTALIATON WITH PGE INSPECTOR vRESEM. H.TRANSFORMER PADS ARE TO BE SET SO TUT THE TOP 132 MCIIES ABOVE FNA'FIZT.OCONW N ISS TOOIRBE1,T.,pALLFD IN PAD A3INDICATEO M DETAIL 19. 8. BUILDING WALLOROVERHANG MN 4 FEED S(FEET FROM ANY FIROM E HYDRANNTSTIBLE PGE TRANSFORMERS MUST BE WITMN 15 FEET OF A ORNEABLE AREA. __. rt __ ALWAVSMAINTMN IO FEET CLEARANCEMFRONT OF ALL TRANSFORMERS. I i i 9. SHRED CRSIER POSTS ARE REQUIRED AROUND TRANSFORMERS THAT ARE EXPOSED 1 _ I 10.1N NEEDEDFRONT LOT PUBLIC UTILITY EASEMENT(P.O.E.) TO BE8 FEET(MIM. FEET IPREFERREW. INSTALL I-2"POLE CONDUIT UNIT W/12" 11.CONSULT WITI PGE REPRESTRSC NE 2 WEEKS BEFORE STARTING TC4 PCOSF TRENRD FORA PRECONSTRUCT Ab CONFERENCE.INCLUDED IN THIS CONFERENCE I--- , BRACKETS WEL BE EXCAVATOR.PGE,TELCO.CAN,AND GAS. K92• I' '' STOMERTRENCHANO ELBOWCONFIGURATIONS ALLCONDUTVAULTANDPAD 2 INSTALLATIONS MUST BE INSPECTED BY PGE PRIOR TO BACKFRL NG WHEN YOU ARE READY FOR PGE TO INSPECT(AFTER INSTALLATION SCOMPLETq 50})36-5150 I B I J OR SO3d63<318(SALEM AREA ALLOW UP TO 2 WORKING DAV FOR CALL TO OCCUR � --- \ � I.I. � � REFER TO THE PGE ELECTRIC SERVICE REQUIREMENTS BOOKLET FOR SPECIFIC REQUIREMENTS. ` v` 19.DESIGN IS BASED ON STANDARD UNDERGROVNDEWIPMENT Np13TAlOARD 1RJ0ER- I /�►� - GROUND EW PMEM MAV BE AN OPTION AT AN NDDITIONAL COST TO THE LUSTOMFR 20, L`IEEE/"2 5�4(�,l THINK PGE CONSTRUCTION DRAWING 12103 Yr w y PL SAFETY AS-BUILT VERIFICATION & NESC VIOLATIONS CORRECTED PL 12IOJ FIRST! TNF d«um.nl accurate, ASSET 4 196611 na FIELD COrulvclbn Foreman: .< Dote: General FOnIHMRI Date: CONTACT SERVICE COORDINATOR (Signature only required for field construcllon changes.) CREW TO ENERGIZE EXISTING 49W LED LEOTEK CUSTOMER TO CALL PGE SERVICE DESK a FOR TRENCH AND CONDUIT MSHCTXIN PRIOR SDPMENG REVIEW: I ASBUILT BY DESIGNER: FIXTURE ON EXISTING DIST POLE#12103 WITH 503-323-6700,TO SCHEDULE CREW STAND BYTRENCHML OAT:4450IR sCAL Mg IA<couNT:107uDm InwO. 1000009106 II NQ.902619695 EXISTING 10'MAST CONNECT @240V WHILE PLUMBING INTO EXISTING VT 94 m SERWCE COOROMMTOR WORM. TITLE 503-3234700 CM 900-542-99T9(SMFAI) ` C72nd Avenue Property LLC/City of Tigard/72nd Ave Apts eR0leX�RIIIBRIMISONIXMMYIIMMILX MCUIT F �I — ! CALL 811 BEFORE YOU DIG WEST PORTLAND-72ND sz 17x22 ATTENTION: PGE ,ION OREGON TAW REWIRES YOU TO FOLLOW RULES ADOPTED 1 r. f , '11740 SW 72ND AVE,TIGARD BY THE RULES AR SET FY NOTIFICATION IC OAR 9 CENTER. '� A��a THOSE RULES ARE 10T FORTH IN OAR CAR COPT S ` CR1511DESCRSR N AL �'I THROUGH 952-0OI-0090.YOU MAY OBT4N COPIES OF Imroll LO A41X ST LT Circuitry In I,I-conduit ro 1-0BW TMs and 149W LED COMPORT @ 24G 1� �� � THE RULES BY CALLING THE OREGON UTILITY W �ECnO(R) WORK WITH 2 SHUT ,_,..=....w.....,,,.............=_.X NOTFIUTIOH CENTER ADMINISTRATION N (50}232-N87) WILSONVILLF WILSONWLLE ICI736D w'O2 '"2'x I OF I �ARp, a�WBrr TO REQUEST UTILITY LOCATES CALL THE OREGON CREW CENTER OESON ay v Rr UTILITY NOTIRCATON CENTER BRAT LEAST611, Know nII b672-5417(503)I •^----- 2 BUSINESS DAYS PRIOR TO EXCAVATION. COLI k. „oft. �msr To.sroro ROUwO SOUS SUMTHA NARAYANAN 0 PORTLAND GENERAL ELECTRIC CO.-ALL RIGHTS RESERVED Page 84 2011 Edition Stationary Lane Closure with Flagging Diagram 320 Diagram 320 covers total closure of one lane of a two-lane, two-way roadway. See the detail inset for the layout if using a single flagger to control both directions of traffic on low volume roads (less than 400 ADT)with good sight distance as discussed below. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3—Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. Flaggers at each approach are required if any of the following conditions exist: a. Night Operations. b. Work space is over 200 feet in length. c. Sight distance is less than 750 feet from each approach through the lane closure. d. Traffic volumes are greater than 400 ADT. 4. The length between the Flagger Ahead signs shall not exceed one mile. Use Diagram 340—Lane Closure with Pilot Car if exceeding one mile. 5. Cones should be used to outline the work space when curves or other roadway alignments prevent clear direction for the motorists to pass the work space safely. 6. Cones along the work space are recommended when posted speeds are 45 mph or greater, when working under heavy traffic or when travel lanes are narrower than 11 feet. 7. Extended queue signing (see Diagram 5-4) should be used when traffic queues extend beyond the initial advance warning sign. 8. When flagging near an intersection, the"Flagger Ahead" (CW23-2) sign should be visible to traffic entering from any side road. Additional advance warning and Flagger Ahead symbol signs may be placed on the side road(s). 9. Sign set-up and flagger placement shown may be used for intermittent full road closures of 20 minutes or less. 10. The"ONE LANE ROAD AHEAD" (W20-4) sign is optional and should be considered on high volume or high speed roads, or when extended queues are expected. Chapter 5 December 2011 2011 Edition Page 85 Stationary Lane Closure with Flagging Diagram 320 /o\ ��3/ • W ,� • a• loe o o �; a) m mea m Q LU ~ , , . . . _ U Oer • •• ti„, • N dm 14, .� •• 30x1 U C.... ,0 � t 1j a m `A1 1 m °lam m�T E >:;1 a lm co — 1 1- 0 it • a _e. 1s 1.. II: • •• . 40,1 �` Q /cc O _ 0 m17, Wcc a CO Sign Spacing and Buffer Lengths(feet) t V iC Posted Spacing Between Signs Buffer . Up Speed A B C Space ♦ zp O 20 50 25 100 100 100 75 30 100 Y Q0Q 40 350 350 350 150 O O W 45 - 180 0 50 500 500 500 210 55 250 December 2011 Chapter 5 Page 106 2011 Edition Diversion into a Continuous Left Turn Lane Diagram 430 Diagram 430 shows work in the travel lane(s) next to a continuous two-way left turn lane with one direction of traffic diverted into the continuous two-way left turn lane. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3—Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. When two or more travel lanes are reduced to a single lane before the diversion, each lane shall be closed separately. Layout traffic control according to ODOT Standard Drawing TM 852 for 5-lane sections. 4. A shifting taper(L/2) may be added in the diverted traffic direction across the continuous two-way left turn lane (as shown). This option is recommended when the speed is 45 mph or greater. Sign Spacing and Buffer Lengths(feet) Posted Spacing Between Signs "Buffer" Speed A B C Space 20 50 25 100 100 100 75 30 100 35 125 350 350 350 40 150 45 180 50 500 500 500 210 55 250 60 285 65 700 700 700 325 70 365 Chapter 5 September 2016 2011 Edition Page 107 Diversion into a Continuous Left Turn Lane Diagram 430 ROAD WORK A AHEAD B lCENTER I fiI / LANE I I CLOSED AHEAD II U2 I • I • • t I :Buffer •T Protection Vehicle w/TMA(both Optional) • See Chapter 4 T 0 / � 1• � Buffer T � . . • U2 11 ' • • L/2 I• I A • 611 lyt u ROAD WORK AHEAD September 2016 Chapter 5