PFI2019-00197 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT COMMUNITY DEVELOPMENT Permit tt: PF12019-00197 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 06/24/2019 T[GARD Parcel: SEG643 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: PGE Project Description: SEG 643. Install one pole and replace one pole. M2360514 Owner: FEES Description Date Amount PFI Permit Fee 06/24/2019 $300.00 PHONE: Contractor: PHONE: FAX: Applicant: BRAD PISTRORESE 10800 SW AVERY STREET TUALATIN, OR 97062 PHONE: 503-718-6323 Total $300.00 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant See application Signature: Issued By: Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PFI2019-00197 Type: Condition Name: Status: Severity: PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition,free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work,effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes,etc. shall be reinstalled or replaced,with like kind of material. Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept.of Transportation, FHWA, current edition,American Traffic Safety Services Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area. Traffic control devices, flag persons, etc.,shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503-629-0111 (Tigard Police Dept.,Tualatin Fire&Rescue)and to 503-962-8140(Tri-Met) and 503-431-2345(Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08-TRAFFIC CONTROL ADVANCE WARNING Applied Notice Advance warning of traffic disruption shall be provided to the public by placement of an approved advance notification sign at each end of the construction area 72 hours(min.)before initiation of construction work. PFI_Utilities 09-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI_Utilities 10-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m. to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 11 -TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 12-TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 13-DRAINAGE CONTROL Applied Notice Drainage shall be controlled within the work site and shall not adversely affect adjacent private property, public property and the receiving system. The City may at any time order corrective action and suspension of work to accomplish effective drainage control. PFI_Utilities 14-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080.Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 15-UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 16-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 17-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities(roads, ditches, etc.)as may be necessary, as determined by the Inspector, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 19-PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity,the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert Phone#>, to establish a preconstruction meeting. PFI_Utilities 20-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. PFI_Utilities 21 -PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 22-DAILY INSPECTION REPORTS Applied Notice Applicant shall submit daily inspection reports, on a weekly basis,to the City's Inspector. PFI_Utilities 23-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 24-VALIDATION OF MATERIAL/CONSTRUCTION Applied Notice The City's Inspector may, at his discretion, require tests and or reports from the applicant to validate claims of material or construction adequacy/compliance. Such tests/reports shall be provided at the applicant's expense. PFI_Utilities 25-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have authority to resolve problems,take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing, of any/all assignment changes. PFI_Utilities 26-RIGHT OF ENTRY/EASEMENTS Applied Notice Applicant to obtain proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry or properly executed easements, shall be provided to the City. The City shall in no way be construed to be liable for the applicant's failure to obtain or provide for proof of right-of-entry or easements. PFI_Utilities 27-PRIVATE PROPERTY AGREEMENTS Applied Notice Provide the City a copy of an executed agreement[s]from the owner for each private property disturbed by construction activity. PFI_Utilities 28-AS-BUILT DRAWING Applied Notice 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also,any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also,any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). PFI_Utilities 31 -OTHER Applied Notice Other RECEIVED City of Tigard JUN 2 4 2019 PFI#:2019-Ooton lig . ENGINEERING DEPARTMENT CITY OF TIGARD P NNTNG/ENGINEERING TIGARD Public Facilities m roveme nt 'FI) Permit PROJECT INFORMATION TYPE OF WORK Project name: M2360514 E TYPE 1—Franchise Utility Work performed by NWN,PGE and/or Brief description of project: utility agency Install one pole and replace one pole © TYPE 2—ROW Sidewalk/Driveway/Sewer Work performed for the purpose of: • Sidewalk installation or repair. SITE INFORMATION • Driveway approach installation 10250 SW Tiedeman Ave � G914,3 and repair Location (address if available): • Sanitary sewer lateral installation and main to across street at 11440 &cross street is SW North Dakota St,Tigard line tap ❑ TYPE 3—Full scale Development Work performed with Land use APPLICANT INFORMATION approval which includes any of the following: Name: Portland General Electric • Subdivisions or Partitions Mailing address: 10800 SW Avery St • Street widening • Mainline installation for Sanitary City/State: Tualatin,Or Zip:97062 sewer,Storm sewer,Tigard water and Tigard Water Service Area Phone: 503.718.6323 111TYPE 4—Small Cell Technology prereqcoord@pgn.com Email: Phone: ❑ TYPE 5—Tigard Triangle Contact name: Brad Pistrorese- SDPM Phone: Email: CONTRACTOR INFORMATION 0 Same as applicant Name: PGE CREW CCB Number: Mailing address: City/State: Zip: Phone: Email: ENGINEER INFORMATION Name: Mailing address: City/State: Zip: Phone: Email: ADDITIONAL INFORMATION Estimated value of work is required(if over$5,000):$ 20,234.87 (within the public right-of-way) Is work related to a LAND USE DECISION? 0 Yes El No Case number: City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 1 of 4 APPLICANTS NOTE: Person specified as"Applicant" shall be designated"Permittee"and shall provide financial assurance for work,if required by the city pursuant to TMC 15.04.140. * With the exception of a utility operating pursuant to a valid franchise or license with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner must sign this application in the space provided or submit a written authorization with this application. Franchised or Licensed Utilities are not required to obtain the owner's signature on the application. I, the applicant,certify that: • To the best of my knowledge,all the information provided within this application package is complete and accurate. • The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject property. • If the application is granted,I will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. L Ott- Linda Ott for Brad Pistorese 6/19/19 Applicant's or authorized agent's signature Print name Date Property owner's signature (if required) Print name Date STAFF USE ONLY Case No:'120M—W 19.7 Permit fee: 3 OQ Received by: ?1`1- Date:(0 24 1�l Approved by: r•erly Date: G/2 6//20/Y Notified by: Date: l6/ City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-ot:gov • 503-718-2421 • Page 2 of 4 DEVELOPMENT ENGINEERING FEES Public Facility Improvement(PFI)Permit: INITIAL PFI PERMIT FEE Part 1: Required submittal fee is 10%of the Net PFI Permit Fee.See below for calculations. Minimum of$300. NET PFI PERMIT FEE Part 2: All non-water system improvements engineer's estimate X 7% (less the initial PFI Permit Fee). WATER LINE CONSTRUCTION FEE Part 3: All public water system improvements engineer's estimate X 12%. FOR STAFF USE ONLY FOR STAFF USE ONLY TYPE 4: SMALL WIRELESS FACILITY TYPE 1—3:DETAILED SUBMITTAL CHECKLIST REQUIREMENTS Does applicant have a right-of-way license? 0 Yes 0 No TYPE 1 AND TYPE 2-Must include a sketch showing: Under the wireless facilities standards,is the proposal ❑ Dimensions considered?(check all that apply): 0 Small Cell 0 Macro ❑ Street Name How many install sites are proposed as part of this permit ❑ Site ddress application? TYPE 3-Must provide 4 sets of plans (sized 24 x 36 or 22 x 34) and an electronic version of all submittal The proposed equipment is located on which of the following: items. The plans must that include: ❑Public Right-of-Way 0 Private Property ❑ Cover—Site,Vicinity,Abbreviation,Legend If equipment is to be located on private property,describe the ❑ General Notes (City,Water,Sewer,etc.) type&use: ❑ Street(Plan,Profile) ❑ Water,Storm and Sanitary(Plan Profile) LI Water Quality Facilities ❑ Grading ❑ Landscaping/Tree Plan ❑ Composite Utility Plan(Electrical,Phone,Gas, Storm, Sanitary,Water,Signage,Street Lights,etc.) ❑ Details ❑ Traffic Sight Distance ❑ Signing and Striping ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label(project land use name,revision and plan log block,dates and sheet numbers.) ❑ Engineer's Construction Estimate Additional Submittals (per land use conditions,if applicable) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design ❑ Water Provider Approval City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 3 of 4 Edge of Pavement Streetlight Ditch --- .— / t ' 7 ' ol. 1 T—�Pro mwer5'e1werTrng-- '^• 1 1 Q) „� I -11 . Existing House 1 t:. 1 Existing ,I 11 Driveway • mi og I 1 CI i I a, ' H t 41 uI .. v-i eo v I a iv'� 1 �I cia �, 1 i 1 1 0 1 Existing Shop � \aa i Powerpole i 1 i 0 • 0 1�in i' I 95' -----I p------ -—- i TioPerty Line— I i I 0 Fire Hydrant(FH) I i 1 i Scale: 1"=30' I 1 • • I i • I 1 • I 1 TYPE 1 AND TYPE 2: MINIUM SKETCH REQUIREMENTS (Put N/A if not applicable) North arrow Property lines&dimensions Existing utilities locations (sewer, storm,water) Street& street names All existing structures Proposed work Existing curb or edge of pavement Utility&street light poles Existing S/W or D/W apron Slope of property Trees City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 4 of 4 www.invarion.com Rail Grade Crossing Diagram 5-9 ROAD I WORKt AHEAD C ONE LANE I B (Optional) ROAD AHEAD B I BE PREPARED A TO STOP 4> Tit I ..� •• 50 ft-100 ft •• 4 Buffer ••j 1/ •� Do not place devices • 1, Crossing Gates between crossing gates II 11111111111 11111 1 i 20 ft •• ••• 50 ft-100 ft I ••Tirg 1:// VBE I PREPARED B TO STOP B I V I ONE LANE ROAD (Optional) C AHEAD I4 Vim` ROAD WORK AHEAD www.invarion.com Rail Grade Crossing Diagram 5-9 Diagram 5-9 covers work in the travel lanes near an at-grade rail crossing. This drawing should be consulted whenever traffic control may cause traffic queues to form up to and/or across the rails. 1 . When work will be done within the railroad right-of-way, the railroad or transit authority shall be notified. Contact the ODOT Rail Division (503-986-4321) or visit the ODOT Rail Division website for the Railroad Contact list to locate the contact information for the appropriate agency. 2. Minimize the possibility that vehicles may be stopped within the rail crossing, defined as being 15 feet either side of the closest and farthest rail. Position the work or shadow vehicle to keep traffic from stopping near the rails. 3. If any permanent "DO NOT STOP ON TRACKS" (R8-8) signs are obscured or if none are posted, a regulatory DO NOT STOP ON TRACKS sign shall be placed on the approach to the tracks. 4. Place the DO NOT STOP ON TRACKS sign on the right and near the stop bar, if there is one. If there is no stop bar, place the sign at least eight feet from the tracks. On multi-lane roads, a left side sign may be needed especially if there are three or more lanes in any one direction. 5. If the queuing of vehicles across the tracks cannot be avoided, a law enforcement officer or flagger shall be provided at the crossing to prevent vehicles from stopping within the rail crossing, even if automatic warning devices are in place. Flaggers shall be certified by the appropriate rail or transit authority. 6. Maintain pedestrian access across the tracks or close the pathway. Use cones or Type II barricades and a "SIDEWALK CLOSED" (R9-9) sign if work impacts the pedestrian crossing. Place the closure where pedestrians are directed to an alternate safe passage. 7. The "ONE LANE ROAD AHEAD" (W20-4) sign is optional and should be considered on high volume or high speed roads, or when extended queues may be expected. Page 52 2011 Edition Bicycle and Pedestrian Accommodation Diagrams The following practices and details address the accommodation of bicycles and pedestrians within work zones. The following detail drawings should be incorporated, where appropriate, into the traffic control plan for any short term work. 1. See Section 1.6—Bicycle and Pedestrian Considerations for additional guidance. 2. Stay alert for pedestrians and bicycle traffic and accommodate safe passage for them, as needed. 3. The work space should be protected from bicycle and pedestrian intrusion by using barricades or closely-spaced channelizing devices. 4. Maintain access to transit stops or clearly close a transit stop using barricades or channelizing devices. Bicycle Accommodation Diagram 5-6 Bicycle Accommodation Principles: 1. If a significant volume of bicycles can be expected and work closes a marked bicycle facility, or requires bicycles to share a travel lane, install a"(Bicycle)ON ROADWAY" sign (CW11-1) or the Bicycle symbol (W11-1)sign with an"ON ROADWAY" (OBW1-5)rider, in advance of the work area. 2. Install temporary signing off the paved shoulder,within the planter (buffer)strip, or share the width needed between the shoulder and the sidewalk, as available. N 3. Signs are to remain in place until the surface is restored and the width o made available for bicycle use. See Diagram 5-6 for typical bicycle signing placement. TO Sign Spacing and Buffer Lengths(feet) Posted Spacing Between Signs Buffer Speed A B C Space 20 50 25 100 100 100 75 30 100 35 125 40 350 350 350 150 45 180 50 500 I 500 500 210 55 250 Chapter 5 December 2011 2011 Edition Page 53 Bicycle Accommodation Diagram 5-6 NOTES: • Bicycles on Roadway(CW11-1)sign should not r standd un . r : BEinterrupt PREPARED TOeSTOP/Flagger Symbol LANEarCLOSEDseqcesAHEAFoD/Laneexampley Ends Work Symbol ti l • Bicycles on Roadway sign typically follows ROAD Area WORK AHEAD sign and used as general warning A i 1 j ! 1 1 ; A l I I I b ' B o i , d 1 V ON ROADWAY I i C V ■ ROAD 1 WORK AHEAD December 2011 Chapter 5 ABC 556 AAC N4/o AACWL1 PL-3933: —ABC .�.�' os5 OVERHEAD LEGEND SW NORTH Install: / 15 34061 DAKOTA ST PL 85'-H1 -----------1 C 15 34059 MIE REMOVE ABANDON FACILITIES INSTALL FACILITIES ® 1'SOUTHWEST MI MODIFYITRANSFERANSTALL ADDITIONAL FACILITIES 6942 75 722-DVS DOUBLE D 2 DFIR REFER TO SAG CHARTRT FORFOR STRINGING TENSIONS 1 WORK LOCATIONS TIS-APS(JUMPERS) D131 POLES WILDLIFE PROTECTION r—POLE CLASS(1,2,3,4,H1,HZ S) (3)1P 25KVA OH 120/2407.2 NTl CB HT LL 1ACCOUNT 13.25kWAI—POLE HEIGHT 039-TR- (MID)-7#(NE) G19-TRAN(TOP)-11,6309 // G19-TRAN(MID)-10,439# FRAMING TRANSMISSION 8 DISTRIBUTION(SEE CODES BELOW G19-TRAN(BOT)-8,4089 151#(NE) T10 _FRAME TRANSMISSION-LC10754,MIS MU 1013 Al-L 10'-1, Gib-PRI-11519 APS,POST POLY INSULATOR ,151Al(EXISTING)-L 8'-2,294#(NW) pre FRAME TRANSMISSION-LC10755,WMS MU 1008 G18-NEUT-2,2949 �,50v9 T16 —AVS-8'/10'SPACING,PORCELAIN INSULATORS AGl 6 L-SEC-1,52#(SW) 61 07:04''' FRAME TRANSMISSION-LC10755,WMS MU 1016 G16-SEC-1,527# 94 PO2\ T22 1992 DVS-8'/10'SPACING,POLY INSULATORS PL 85'-1 FRAME DISTRIBUTION-LC10725,MU 0076 176 16 AVS 5 32939 076 _(3PH,UNDERBLD ANG,DBL 10'LT,HVY BRACE,POST) (3)1P 7.2 120/240 OH 10KVA NTICB NF 25 24551 FRAME DISTRIBUTION-LC10717,MU 0131 Al Kk- 25 50672 0131—(3PH 10FT DBL DE FIBERGLASS,POLY) (3)016 TEMP TRANSFER CG611ua(S), ,1, rIE CL'1(ED 0 O+ -C 10 cC- P� �P ANCHORS z r-GE 70 r'ULL POG x_w= r Z i ¢a • (LEAD) 113 a y , S • A (LBS) b 6764 Anchor code cmcnici 60-2 \ Open 2013 ' GUYING = = 1 O IS c0 10250 TIEG o o 0 o d ° b -0 600 • WL 1 -3 Span' — 5 too ,. N :o • •OS:.LBS. �C O 1•43 (3)G1 1 GUY m�m1;Y1Vr-EC N ' �� & � 2 GUYS oma m �PP o ,9 3 GUYS m � oE ,g_7' f ',r,o 1 � ,c,3 4- Z 3 O 3933 85'1) TREE TRIMMING NOTES Hl DFIR 40 6941 35 WL1-PL-3933& :25 - . 1 DFIR + WL2 NEW PL-422: NOTES -25A 1011378 fl C , 25 B 10 7346 Qy LEAR AREA FOR NEWPRE LANDSCAPING 3933 C 10 7449 ��G,° POLE 8 ANCHOR &WL2 NEW PL-422: CLEAR AREA FOR NEW POLE& WL 1-2 Span: ANCHO'1 Install: G4 170' G -TRAN(TOP)-4,897# "f--.. r G4-TRAN(BOT)-1,407# 44/ V WL3PL 6941: Remove: Zi A3 O4/ Q (2)G19 N IC4 Transmission Stringing Chart-795 KCM AAC(Arbutus) C PL3933-P16943 PL3933-PL3936 h e 422 Span Length=362' Span Length=266' ^'''2 40'-2 2 / None Temp(F) Mid Span Horiz. Mid Span Tension Haas .1-Qt 2 Sag(ft) Tension(lbs) Sag(ft) ( nsi 30 4.73 2586 2.44 2706 WL 2 NEW PL-422: 40 5.16 2370 2.78 2380 Install: 50 5.58 2188 3.13 2116 PL40'-2 170'SOUTHEAST OF PL-3933 60 6.01 2035 3.48 1901 LOCATION IS STAKED 11440 70 6.41 1906 3.83 1729 A3-L 15'-19,096# A 25 33558 80 6.81 1794 4.17 1588 b G20-TRAN-19,096# B 15 49681 90 7,20 1698 4.49 1472 c 0 100 7.57 1615 4.81 1376 °' ABN 2 ACSR 0 Q 25 •0 z-tazl{AfTeet 110 7.94 1540 5.11 1294 V t I I C 3906 78 2 DFIR 120 8.29 1476 5.40 1225 115_30 PGE CONSTRUCTION DRAWING AS-BUILT VERIFICATIONANESC VIOLATi0'.<I:?lCF'ECTED /HIN\ Foreman: o Date: General Foreman: Date: SAFETY (Signature only required for field nonslmcllov changes) \IRS\ SDPM'ENG REVIEW I ASBUILT BY DESIGNER: -- - ----- - DATE SCALE' ACCOUNT AWO: JOB NO ANY DEVIATION FROM THIS DESIGN MUST 2/25/2019 1 in=50 ft 1070001 1000005387 M2360514 BE APPROVED BY THE PGEPROJECT MANAGER TITLE TRANSMISSION 2017 FPI-PROGRESS-WEST PORTLAND 115KV- _ REPL BIO PL3933&INST NEW STUB POLE CALL 811 BEFORE YOU DIG /. CIRCUIT TRANSMISSION:PROGRESS-WEST PORTLAND SIZE ATTENTION: C\ DISTRIBUTION:TIGARD-13361 17 x 11 OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED H' PGG LOCATION BY THE OREGON UTILITY NOTIFICATION CENTER. 11343 SW TIEDEMAN AVE,PORTLAND THOSE RULES ARE SET FORTH IN OAR 952-001-0010 811• / DESCRIPTION THROUGH 952-001-0090 YOU MAY OBTAIN COPIES OFREPLACE B/0 PL3933&INSTALL NEW STUB POLE SHEET THE RULES BY CALLING THE OREGON UTILITY Mr N. COUNTY SECTIONS WORK WITH NOTIFICATION CENTER ADMINISTRATION @/502-232-1987) WASHINGTON C1135C 1 OF 1 TO REQUEST UTILITY LOCATES CALL THE OREGON KnswB�.rm� sBMW,.at'5beiBMW,. DESIGN BY PHONE DRAWN BY UTILITY NOTIFICATION CENTER,811 AT LEAST taw before pads UNECREWCENTER BRAD PISTORESE 971-275-6779 TARA LEAKE 2 BUSINESS DAYS PRIOR TO EXCAVATION eeAVERroN.oe 07008 ©PORTLAND GENERAL ELECTRIC CO.-ALL RIGHTS RESERVED