Loading...
Report (65) /1/11- ?,otq- 00002- 160 5Lv 1146644k/ S-F. CT ENGINEERING INC 180 Nickerson St. Suite 302 Seattle,WA 98109 (206)285-4512(V) (206)285-0618(F) asolomon@ctengineering.com BULLETIN Date: August 21,2019 Number: CT-66 Project#: 15238 Project Name: River Terrace SF Attached: None Subject: Lot 232 (Plan 3D DLSG)—Sloped Garage Floor Drawings Affected: Description/Action: This bulletin provides response to RFI, design clarifications and/or variation requests for the 'River Terrace SF' project located in Tigard, Oregon. Per our discussion with Polygon, it's our understanding that the garage floor currently slopes from the front of the garage to the back of the garage. Based on our review of the plans, a proper resolution would be to add the following materials directly on top of the pressure-treated plywood floor sheathing to create a properly sloped garage floor. Note that items are listed from bottom to top. The existing structural framing system shall not be altered: *Wood shims * Plywood floor sheathing �� OS Waterproof membrane TF• ik *4" concrete slabyOREG��NA, •.4FS T T. \e„\- (,,,, \\F�` 08/21/2019 CALL WITH ANY QUESTIONS Distribution: Contact Information: Frank Sandoval Polygon Northwest Company Chris Roberts Polygon Northwest Company David Burnett Milbrandt Architects R:\15238 River Terrace SF\Bulletins\15238_2019.08 21_CT66_Lot 232(Plan 3D DLSG)-Sloped Garage Floor.doc Structural Engineers