Report (65) /1/11- ?,otq- 00002- 160 5Lv 1146644k/ S-F.
CT ENGINEERING
INC 180 Nickerson St.
Suite 302
Seattle,WA 98109
(206)285-4512(V)
(206)285-0618(F)
asolomon@ctengineering.com
BULLETIN
Date: August 21,2019 Number: CT-66 Project#: 15238
Project Name: River Terrace SF Attached: None
Subject: Lot 232 (Plan 3D DLSG)—Sloped Garage Floor
Drawings Affected:
Description/Action:
This bulletin provides response to RFI, design clarifications and/or variation requests for the 'River
Terrace SF' project located in Tigard, Oregon.
Per our discussion with Polygon, it's our understanding that the garage floor currently slopes from
the front of the garage to the back of the garage. Based on our review of the plans, a proper
resolution would be to add the following materials directly on top of the pressure-treated plywood
floor sheathing to create a properly sloped garage floor. Note that items are listed from bottom to
top. The existing structural framing system shall not be altered:
*Wood shims
* Plywood floor sheathing �� OS
Waterproof membrane TF•
ik
*4" concrete slabyOREG��NA,
•.4FS T
T. \e„\- (,,,,
\\F�`
08/21/2019
CALL WITH ANY QUESTIONS
Distribution:
Contact Information:
Frank Sandoval Polygon Northwest Company
Chris Roberts Polygon Northwest Company
David Burnett Milbrandt Architects
R:\15238 River Terrace SF\Bulletins\15238_2019.08 21_CT66_Lot 232(Plan 3D DLSG)-Sloped Garage Floor.doc
Structural Engineers