Plans (281) 5T HP Project: -Untitled220 07/11/2019 Prepared By: 02:17PM 5T HP Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet OFFICE COPY CITY OF TIGARD REVIEWED FOR CODE COMPLIANCE Approved: OTI Cs [ j Pcrmlt#: rale(' ,i;cn 19- no 6 3 6 Address: ira,< r-r ph J- p j rd Suite#: 1) o By: y4 Date: 9_3 _ ION OF A DUCTI THE ISSUANCE OF A PERMIT SMOKE DETECTOR L BASED ON CONSTRLICTIO ACTIVATE A VISIBLE AND DOCUMENTS AND OTHER AUDIBLE SUPERVISORY DATA SHALL NOT PREVENT SIGNAL AT A CONSTANTLY THE CODE OFFICIAL FROM ATTENDED LOCATION REQUIRING THE CORRECTION °MSC 606.4.1 OF ERRORS. OSSC 105.4 Packaged Rooftop Builder 1.49t Page 1 of 12 Unit Report For 5T HP Project: —Untitled220 07/11/2019 Prepared By: 02:17PM Unit Parameters Dimensions(ft. in.)&Weight(lb.)*** Unit Model. 50KCQA06A2A6-0A0A0 Unit Length 6' 2.375" Unit Size. 06(5 Tons) Unit Width. 3' 10.75" Volts-Phase-Hertz. 460-3-60 Unit Height 3'5.375" Heating Type Heat Pump *** Total Operating Weight 650 lb Duct Cfg• Vertical Supply/Vertical Return Standard One-Stage Cooling Refrigeration Coil *** Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Return Air Filter Type Throwaway Return Air Filter Quantity. 4 Return Air Filter Size. 16 x 16 x 2 Unit Configuration Medium Static Option Belt Drive Al/Cu-Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(STD.) 5-Year Compressor(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 50KCQA06A2A6-0A0A0 Rooftop Unit 1 Base Unit Medium Static Option Belt Drive None Accessories CRHEATER109A00 12.9/14.0 kW 460/480-3-60, 9.7 kw 400-3-50 Volt Electric Heater 1 Packaged Rooftop Builder 1.49t Page 2 of 12 Certified Drawing for 5T HP Project:—Untitled220 07/11/2019 Prepared By: 02:17PM TES DIRFSIMS AA[ix 71KS.OISFNSIOA3 DRAWING REPRESENTS PRODUCT BUILT AFTER 01/01/2017 i lr:.:ms muss ''''' ....11"..... '." " ' IRI ,AAF n RwC30S (STARTING WITH SERIAL NUMBER 011 I...1 SEE DETAIL "E" 2 (1310*OF 2222214 CONNECTIORSIZES Iry A 1 511•IPA DIA FIELDLD PORI S1224113 DOLE 7.y HUMOR OF 310 FICA, UNIT J I [/6171 I r 1311 0IJ ran UDR,0303*4T 30,0.0. 3)L/ IA ill A__�..ALL VIER MDR 05100 RN 461E IMiI [Slit , C +311'[311 3 0 446E 1331ACCE3S 333FLO1 305,0.03 •Sll to 111 311314 E[MONIXA MDOO. - O 121'I221 DIA MLR CONTROL X14111 HOLE [1ISti [)111 11111 tOPTIdAIt V41 SII 7,111" F SIA•-fA 0T COR04ATf DRAIN "K" ] SI •` 11 [1011 6 7 Set'(1111 OV PORI SUK1F 160,1-OR I,Z1 yy 614141 AIR 1 . 11IND-TIE-SASE GMT j • I • } E♦IOFR THESE HOLES MIRED OSE ( fes ,. . [2/411 611 101111 TIRE 011 O NXE CpiORIT SIX USE FRES<MY.3 N. s7T!kWh,1 R .. 3 R ''t• 2311 UV'IZZ.2I 1-11{ `� '� �•• ( I 324' IER l-IIH 1121 c 111111 E Mi. 1 FM'100-THE-/AS(!4•FACTOR/OPTION, COIDENSATE 11-311 y FITTIKs FOR DR/I.c A0 4ROVIDED kolas MOM 1417 13-111 1 1 IF PUPAL St i.' 11-31/147 ygPPll dii, AIR I l 111131 1 • 1-V2 e � 1 U611 -,IZ f _ Al lH,iK It MN?10-1 i5 13 11.1:4— 1-111 1-111 (431 .7 11311 1111 _ 11-1111 13011 SEE DUSK E tx 23— TOP I .. SIM S 363s1 21-311 Int.al n Pg em - DISC ' C' E*0414 116311 _f 1-22;6 11 LOCA11ON {. •• I �.�� CONDENSED —�IUI �� ATp 1.1 7. 1iF1KTalt CDITIOL 1191 • COIL IiSTALLE/ \ ..,`CSS EARL 16-711 673TWRCE `— *1511 3*001 11231 IFTD1/TIYJ) OrrioNAl 7l 1I ACCESS MKL SOM11 AIR 1 ET,N pr.221_1_...._ Rnfilli INSTRLLED ,,,�--------OROOJ CONVE4fEK[ I =-_ ' AO.TLET ' OUTSIDEJ iiui2 [4!971 ,� [SJ9j.. f I 11-31/ f-111 --—'' I „:., - s MANCyE� OLE 1-S221 91 (11❑ [ID21 ir (..'j 25-121 14-311 3101 11019] It-3121 020044 IC LEFT 115.11 SEL(E1 FRONT 3NRPU 4 FUN, I0. MAN RIGHT 1110 FCC!I`SR RTIol ( I OF 5 slim I D-2A 13 16 I 1-17-00,.AI SDECO O/-01 SINGLE RT 404E ELECTRIC I 4/Ri011213 I FA Packaged Rooftop Builder 1.49t Page 3 of 12 Certified Drawing for 5T HP Project—Untitled220 07/11/2019 Prepared By: 02:17PM YOFES. GAIT 1 4 Cca / ,1 ma0040! Ia t.003310[WK RYE[0 3013(0.010600030 316Cp91 33 316 '1'3;1 ,,ur4•^.m.x•rta ei004*�•l. '� [a Cam•n. IA 1 IME IA•t00003i01 [Nil 4 S CEATEA Of SPROITT 59410405 1184,, '131,;' DRAWING REPRESENTS PRODUCT BUILT BEFORE 01/01/2017 A 1 311'041 OWGULP 310640 611771!NM 9*C0.0A �1lfll 73;11SEE DETAIL "B" 0 2'ESE POW 300[3001 3 y OINECIIM Or NR, C 1 314•611 01A CAUSE ACCESS 71.30 1.-El..ALL 616 000311 WING 3PD ANGLE .. 13396 6 IIP 1221 NIA FIELD CONTM.1.1.11 NAE WW1 E 341'-14 NPT C04DEYSATF ORaIA G t 112•1941 DIA POSER SDPRL,900[1-011I • [[0001[16 HOOD • '—f 03110 61/ FIL16 CCEEE PAYEL _ 0*361 Tq#-1F;55 CM. TNRG-INE-6ASE CHART NETU3A AIR H TIES[NCLF3 RCDU31F0(OR USE IRAEL ; C96TW0003A01 7HKa0E9 qRE 3100 NOL[ IAD)dfi COIL • t COA nt Si7E 95F sH2s(YA•Li.: LJ ~ 4�'� \ 1,1 iiI FOA 74-rikIVIPAa'FACIOIT OPT30A, POLE � %1�� I 1 f1TTI11(r0R OIL,Y,,ARE PROvt#0 is 11171 I BACK la � � E ALT 4 1 303[[7(1111.1::"..°%M.31/1 ITN6 311.ORI! TAP \ Cp#ASAI[ 2l-318 OW PpER,DEP6OiN6 QA 110E SII[ .ORAIY[413134 y CURD i ' / f\ U OPSEPM •14531 99111 ii!,6 ,,„/-' � SU19T[43311 AIR PL9 111-141 14-14411597 [/t11 1 13631 �' - 0IEA3[RfN+lT 1 >i i Nv—n25 // IP L41/\ _� / P-114 6510 8_//..,.., J/// [1571 2-104 3011 3 L--3t-1/1 .r—is-vz+. is-t, SEE DETAIL 10101 FPII107 F 310. [163] MEI 3 CONDE;SETS I-t/4 _ --1;41 - y D"AIR 1311 11(61[01 ' _ C001035ER f LOC31103 r OPTIONAL i MD COIL - FACIORI CHER#III IAD004 3307[3 iP-311 25-I IR 1 INSTALLED ACES_PAAEL [CESS 766EL - 14211 II 61 OPTIONAL OISCOPNECT 51770 AIR PEIU6. WT;r# y 10FACTOR, !KE f aIR .1, CCYYFNI[CE IIiiI :'[217"4 I0 A /53[111] 1 / p R='6 4 —�- ..l:r�yt. I �..t« e1OO y , OOA` eoo iWIDE—6/ NAAOL E-Sre I 11491 [1111 31521 si 6-3/4 23-I/6 011911 16621 311101 It 14-510 A[llff LEFT 010361 00-10 FLON yn9Pl, InnFRONT IR ir'JP" RIGHT 11.So UECCACNSB I 2(0 I 5-24 20/6 I DET WTI 31CRc y, 50[CO 01-06 SINGLE REAT PW10"E ELECTRIC ( 451:000203 ( 1;.N Packaged Rooftop Builder 1.49t Page 4 of 12 Certified Drawing for 5T HP Project:—Untitled220 07/11/2019 Prepared By: 02:17PM SID.SNIT 203KI CWKR 200029 COINER C.b. NEI4N1 sure auxnnx*cu.sa e=' 0511• 021GNT KILNT III KI6NT 18) KIL8T IC) YE16Ni 3) •�y�/WM31ln s nsrm tau•1, x< mn.n. Los. t6. LD3. 110. 415. t6. 185. K. LOs. NG. 2 3 2 54020+32 443 224 134 50 118 53 114 53 130 50 35 318 14401 23 118 15443 14 3/8 12611 541E0405 180 243 161 13 111 44 130 53 G2 44 35 1/2 10621 21 1/61555] 23 1/2 13211 50400404 410 216 143 15 152 60 141 44 151 St 30 3/4[4041 22 1/2 25117 20 4/4 15211 .36":15'12; ST+YOAOS WIT W101I IS 41TXOUI[L[[IRIC NG1"7111111%;,:114.T._ ----..—.- - 304 01138 O71ID35 320 40121007103.320E 10 THE i BACK WITH ECONOMIZER I -012.r; CORNER A CORNER B BACK wITR13141• . 1 . • 1 I — ECONOMIZER 'Z" 0 • EC03ONI200iEA 331 N000 2 ! I %amt.too. I mw }U. I L1118t117 l;N. r \ I CORNER ©II CORNER C LEFT — RIGHT I-- Ti.F - I R I „,8 FRONT' 11 — 1 I 2 ROTES. I1T111I]: UC££ u SdIN12 wrtx 6R34tc[98TF! d91AT8O : ______ _ I I. OO^ SURFACE COOIICIUE WNBI IONWIIQICTNE MN�1 CFiWA51t£ MSR 43[1219446] 36 7914,01 18[457,0.1 LiT 48[1219,0] 42(1067,07 181457®37 FRONT MGL 48[12194.] 42(1067,0] 18[4511x3] MCC wfEom 36(91448,7 36[914m1 18[451,0] NCCR 36[91Im1 36[914,01 18[45709] 'Mr 12[1829,07 12[1829,0] 72(18244.1] I3.5UEC16:41 I 3 �F5 I D 24-2"11116 4-17.2014 I SORCO 04-06 NEAT 3)33 514010 E ELECTRIC I 4842000283 I IR Packaged Rooftop Builder 1.49t Page 5 of 12 Certified Drawing for 5T HP Project:-Untitled220 07/11/2019 Prepared By: 0217PM CIPCIer R i >ax elrr<.TE 4T. x x E T Teruo xEZE. 4 a. - lt-lle IINSIDC TIE 012[RAIL 1011511 0• 1011 oil 1 tlxslOF ilE OAS[ Its ` � . 011 .. .. .. ik IIII / % - INSIDE BASERAIL DIN€NSIONS 1p11 N I nal 7 iII j(411 �� �- y1� NOTTON ��IZ1/7,�ii 11�� 1,._.. 111 1 11/1 1251 3-114 022 --e14 0-T1s nal 11s1 DETAIL C TOP 4 PLCS r SLITS ACCESS 5150L .max: - CACCEAOL 50I IxODDR BLOx@ TOOL4Ts4 4AXE'S .0 u.t.4,. CCESS IAgI ACCESS OANEI mit . II1 Axexa Ti. E. 111111 I. / .. :CESS Ti !_ SFE DETAIL C ��o I i I iIs 11 ) i9�t) 1) U n ( ( i _o � I i I 1 I It I: Ill I -:Y LEFT c?a' T-IOH .«- NITOOrNSTA (1811 18-318 (15011 FRONT nU<.CSL.ASESC0CFNIC:ATSIRo4 I I 51OF T5 I 8-27T2E015 I 15-511r52001(151 I 501CO 04 OS HSEIANTGL°E04T1ONE ELECTRIC 4810000283 1 A Page 6 of 12 Packaged Rooftop Builder 1.49t Certified Drawing for 5T HP Project:—Untitled220 07/11/2019 Prepared By: 02:17PM .•NRNP.N..,i,D..1. Pg,•IE 6«„ «<A.TIA N a IR.iE N 11110-TRE-BASE CRAIT TULSA ICS SEOOIRFC FOR SSE CRSTAPR400IA61 TMRUOED NINE IC0'0 EOIE TNte so TXi g51RAQI FCCC AXE CpWWT SIZE NY SIRS ow.. ■ ITE' 115,1 til'132.23 TRREACEO SIRE SE0'12 NOLL i)t' 210 111'[22.31 CONDUIT SIZE USE SIZES UNIX 1 v. Sit' RORER 1 It6•00.61 I la' ,ISN T/6'COSTS EOR TEIG TR X CO/AM.Y ACTORY OPTION. I Iii' 245' SII'112.21 FITTINGS FOR OYY R[LRovIJFO I 311• 'PMER I-1IE•E26.6I SELECT CITIES 114'OA Ill' FOR•TNIN-TIF-EASEPDX'FACTOR.OPTION, • FOR PORES,OEPEXOING OX RISE SIZE FITTI465 FOR ONLY R.7 ARE DE NIDEO • II �/'^6 ii ; I T ii IS-,f* 'I ; I • ; ; 145,1 ,� I ; � .• • I1„iI II iI � I [56113 1 / ��'. iI 1-112 R I ES631 11 II I 'iE 1211] [356] I I I1 I i II ; I I I . e • • • • • ; I II 1 < II _ I I ; 31 23-311 I Ix is I I I 1{03. [636] I l i 2125 DETAIL 6 I I 16351 I I I ace sun Z I I ERONISNEET I THIS VIEW REPRESENTS PRODUCT BUILT PRIOR TO 1/1/17 THIS VIEW REPRESENTS PRODUCT BUILT AFTER 1/1/17 ITC CLASSIFICATION ENACT DAT[ SNPERCEDES SCF:.^04-C6 SEAT E ZONE ELECTRIC 486C000211! IAv 11.5.ECCR:NSR 5 OF 5 B-24-2016 04-16-2014 Packaged Rooftop Builder 1.49t Page 7 of 12 • Certified Drawing for 5T HP Project:—Untitled220 07/11/2019 Prepared By: 02:17PM Service Clearance 111111'1 11 10 I <da337 LOCATION DIMENSION CONDITION 4414n(1219 mm) •Unit&connect Is mounded on panel A 18 (457 mm) •No disconnect,convenience cutlet option •Recommended service clearance 12.6,(305 mm) •Minimum clearance 424n(1067 mm) •Surface behind servicer Is grounded(e.g.,metal,masonry wall) 9 36-in(914 mm) •Surface behind servicer is electrically non-conductive(kg.,wood,fiberglass) Special •Check for sources of flue products within 10-ft.of uat fresher,Intake hood 36-In(914 mm) •Side condensate drain 6 used 18-in(457 mm) •Minimum clearance 48-in(1219 mm) •No flue discharge accessary installed,surface is combustible material 42-in(1067 mm) •Surface behind servicer is grounded(e.g.,metal,masonry wall,another Wt) D 36-In(914 mm) •Surface behind servIcer is electrically tonMnducdve(e.g.,wood,fiberglass) Special •Check for adpcent units or buiidIng fresh air Intakes within 10-ft of this units flue outlet NOTE:Unit not designed to have arenhead obstructor.Contact Application Engineering for guidance on any application planning overhead obstruction or vertical clearances. Packaged Rooftop Builder 1.49t Page 8 of 12 Performance Summary For 5T HP Project: —Untitled220 07/11/2019 Prepared By: 02:17PM Part Number:50KCQA06A2A6-0A0A0 ARI SEER. 14.30 Base Unit Dimensions Unit Length 74.4 in Unit Width. 46.8 in Unit Height 41.4 in Operating Weight Base Unit Weight 610 lb Medium Static Option Belt Drive. 10 lb Accessories 12.9/14.0 kW 460/480-3-60, 9.7 kw 400-3-50 Volt Electric Heater 30 lb Total Operating Weight 650 lb Unit Unit Voltage-Phase-Hertz. 460-3-60 Air Discharge' Vertical Fan Drive Type. Belt Actual Airflow. 2000 CFM Site Altitude. 0 ft Cooling Performance Condenser Entering Air DB. 95.0 F Evaporator Entering Air DB. 80.0 F Evaporator Entering Air WB. 67.0 F Entering Air Enthalpy 31.44 BTU/lb Evaporator Leaving Air DB. 60.0 F Evaporator Leaving Air WB. 58.1 F Evaporator Leaving Air Enthalpy 25.12 BTU/lb Gross Cooling Capacity 56.83 MBH Gross Sensible Capacity 43.20 MBH Compressor Power Input 4.79 kW Coil Bypass Factor 0.156 Heating Performance Outdoor Ambient Temperature. 47.0 F Entering Air Indoor Coil DB. 70.0 F Leaving Air Indoor Coil DB. 95.9 F Total Heating Capacity 55.90 MBH Integrated Heating Capacity — 55.90 MBH Heating Power Input 4.07 kW HSPF 8.2 Electric Heating Capacity 12.90 kW Unit Leaving Air Temp- 116.3 F Supply Fan External Static Pressure. 0.75 in wg Options/Accessories Static Pressure Electric Heaters. 0.11 in wg Total Application Static(ESP+ Unit Opts/Acc.). 0.86 in wg Fan RPM- 1250 Fan Power 1.40 BHP NOTE. Selected IFM RPM Range: 1066-1380 Electrical Data Voltage Range. 414-506 Compressor#1 RLA. 7 Compressor#1 LRA. 52 Packaged Rooftop Builder 1.49t Page 9 of 12 Performance Summary For 5T HP Project: -Untitled220 07/11/2019 Prepared By: 02:17PM Actual Electric Heater kW. 12.9 Electric Heater FLA. 16.8 Outdoor Fan Motor Qty. 1 Outdoor Fan FLA(ea). 0.8 Indoor Fan Motor Type MED Indoor Fan Motor FLA. 4.2 Power Supply MCA 35 Power Supply MOCP (Fuse or HACR) 35 Disconnect Size FLA. 33 Disconnect Size LRA. . 107 Electrical Convenience Outlet None Electric Heater Part Number 109A Electric Heater Number of Stages. 1 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 89.4 88.7 57.7 125 Hz 83.0 79.7 66.6 250 Hz 75.4 67.4 68.7 500 Hz 72.8 65.3 72.9 1000 Hz 72.0 67.1 74.5 2000 Hz 67.1 61.8 71.1 4000 Hz 68.7 57.8 67.6 8000 Hz 65.5 50.9 62.6 A-Weighted 77.5 71.6 79.0 Advanced Acoustics 0 �.. - 0 ..... c LJ 4 0 0 !toiAdvanced Accoustics Parameters 1. Unit height above ground 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground 5.7 ft 4. Height of obstruction 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 57.7 66.6 68.7 72.9 74.5 71.1 67.6 62.6 79.1 Lw Packaged Rooftop Builder 1.49t Page 10 of 12 Performance Summary For 5T HP Project: —Untitled220 07/11/2019 Prepared By: 02:17PM B 31.5 50.5 60.1.69.7 74.5 72.3 68.6 61.5 78.1 LwA C 25.3 34.2 36.3 40.5 42.1.38.7 35.2 30.2 46.7 Lp D -0.9 18.1 27.7 37.3 42.1 39.9 36.2 29.1 45.7 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Fan Curve 20 \SCF. M s1 18 \ N. 16 --4----- ._..„,...,_ \ \ \ I 14 \ 12 \ \' \ 300BHP— O 080 w• -701'TM 2.00BHP N1.50 OOBHP Q4 9IFR l A d'SBHP O. BHP 0 00 03 06 09 12 15 18 21 24 27 Airflow(CFM-thousands) RPM=1250 BHP=1.40 MaximumRPM=2100 MaximumBHP=2.90 Note:Pleasecontactapplicationengineeringforselectionsoutsidetheshadedregion. SC-SystemCurve RP-RatedPoint Packaged Rooftop Builder 1.49t Page 11 of 12 Unit Feature Sheet for 5T HP Project: -Untitled220 07/11/2019 Prepared By: 02:17PM CDCarrier fal WeatherMaker- 50KCQ PACKAGED ROOFTOP HEAT PUMP UNITS-14 SEER 3,4,5 TONS PERFORMANCE FEATURES to AFFMNFOFW • PURON(R-410A)HFC refrigerant C+ i �,,. s "�' • Meets and exceeds AS HRAE 90.1 eneryyefficiencyleveis .... ;. •SEERsupto14.4,EERsupto12.2,HSPFsupto8.0 • Single stage cooling Capacify control ^,- ; • Exclusive non-conosiae composite condensate pan in accordance with ASHRAE62Standard,sloping design;side orcenterdraan • Coppertubealurninumfincods with optional corrosion resistant coils a Pae-paintedextenorpa nets and primercoated intenorpaneistested to � 600 hours salt spray protection ;;��'� • AcutroP refrigerant metering system ' t .� „''"` '"^ • Cooling operating range up to 115E(46C)and down to 25F(-4C) • Solid-state control boo rdand easy access terminal board • Refrigerant filter drier and accumutatoroneach refrigerant circuit • Fully insulated cabinet • Automatic ohangeoverwhen used with auto-drangeoverthemmstat WEATHERMAKER SERIES • Rated in accordance with AHRI Standards 240 • Loss of charge,freeze protection,and high-pressure switches WeatherMaker SOKCQ (14 SEER)units are single-packaged • Dependable Time 1 Temperature defrost board and logic heat pump units that are pre-wired and charged with Puron • Listed by UL and UL,Canada (R-410a)refrigerant.The units are factory tested and rated in MAINTENANCE FEATURES: accordance with AHRI Standard 2101240.WeatherMaker units • Ass panels easy grip handles are designed in accordance with UL Standard 1995,and listed • Innovative,easy starting,nostrip screwfeaturesonunit accesspanels. by the Underwriters'Laboratories. • Two-inch disposable return asNters • Tool-less filter access door • Direct Drive—ECM erdoormotor is standard with optional belt drive systems a Terminal board facilitating simple safety circuit troubleshooting and simp!fed control box arrangement 6 INSTALLATION FEATURES: ASHIRA • Thru-the-bottom powerentrycapabiitystandard i7t�G • • Single point electric connections �� • Full perimeter base rail with built-in rigging ed.ptersand fork truck slots @UMPt1ANT • Field convertible from vertical to horizontal airflow STANDARD WARRANTY: • 5-yearelectric heaters � • 5-yearcampressor A••i�aCERTIFIED_ • 1-yearparts Many optionalwarrantres also available use or•ewm C t+au - OPTIONS INCLUDE BUT ARE NOT LIMITED TO: `'"y""' `•.',",,,,,,, • PremierLink and RTU Open Multi Protocol DDC Controls G (1101 US x +4,0.4 • Supply and Return air smoke detectors • Non-fused disconnect switch and convenience outietoptions woe*rt a High static motor options • CO2 sensor • Corrosion resistant cod options forevaporatorand condenser • Field accessory electric heat and single point kits(field-instated only) • Hinged access panels Certified to ISO 9001 • Integrated economdersystem.Standard and Ultra Low Leak versions Fora complete 1st of options and accessories referto the Product Data Catalog forth is unit. Packaged Rooftop Builder 1.49t Page 12 of 12 M icroMetl Date:1/5/2018 Weights: Units: Part Number:0537-014A-00010 941bs/42.64kg Submitted To: Job: Notes: 14 Inches Tall Non Insulated Full Perimeter Knockdown Roof Curb Without Pitch, Insulated Deck Pan If Applicable, Includes Wood Nailer. C 13/4"Alt.drain hole Opening for thru / 44‘iii Blocked to the bottom electrical ' P t canters connections �R Selected H fight �{ �""�� <-**s*....'"\.....s.,... `�uPPIY I I t'� B Selected Height ilr CROSS SECTION OF CURB -§PP-1 2" 1-in A - I.D. B - 1.0. C - O.D. D - O.D. E F G H I 67.37 37.18 40.68 70.87 13.87 20.25 32.06 13.62 1.75 The Information contained in this drawing is the sole property of Micrometl Corporation.Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited. Indianapolis_3035 N.Shadeland Ave.,Indianapolis,IN 46226_800.MMC.HVAC••Sparks_905 Southern Way,Sparks,NV 89431_800.884.4MMC••Longview_201 Kodak Blvd.,Longview,TX 75602_903.248.4800