Specifications (54) RECEIVE® d 1 p
B+T GRP
Date: May 06, 2019 JUL 1 0 2019
Kevin Nelson CITY OF TIGARD B+T Group
Crown Castle BUILDING DIVISION 1717 S. Boulder, Suite 300
2055 S. Stearman Drive Tulsa, OK 74119
Chandler, AZ 85286 (918) 587-4630
Subject: Structural Analysis Report
Carrier Designation: T-Mobile Co-Locate
Carrier Site Number: P001733D
Carrier Site Name: Scholls Ferry& 175th
Crown Castle Designation: Crown Castle BU Number: 879602
Crown Castle Site Name: BARROWS RD
Crown Castle JDE Job Number: 564291
Crown Castle Work Order Number: 1735475
Crown Castle Order Number: 485007 Rev. 0
Engineering Firm Designation: B+T Group Project Number: 78702.004.01
Site Data: 16744 SW Scholls Ferry Road, Beaverton, Washington County, OR
Latitude 45°25'34.6", Longitude -122°50'53.87"
100 Foot- Monopole Tower
Dear Kevin Nelson,
- B+T Group is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the
above mentioned tower.
The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we
have determined the tower stress level for the structure and foundation, under the following load case, to be:
LC5: Proposed Equipment Configuration Sufficient Capacity
This analysis utilizes an ultimate 3-second gust wind speed of 120 mph as required by the 2014 Oregon
Structural Specialty Code (OSSC). Applicable Standard references and design criteria are listed in Section 2 -
Analysis Criteria. ,\
" \
Structural analysis prepared by: Josselyn Palaci __.
0 E ❑ 0 ❑ ❑ ❑ ❑RLI 6 El CI CI
Respectfully submitted by: B+T Engineering, Inc. 0 c ) CO mu 5 m 0 w.co
5 3 ® "f0
��RUCToys? 9, Z iii. e •.' $ 0 z na. g n ®_m
���ED PRpF S< - 8 ® el- pt i� `4 F 6 95
90767- . r �� . rn 4� 1 c 3
m ? m ; _ era tt , t
8 ‹ cr, {._s chi Ti �+} p Ill
— Gs = dl] — gj 4D_ 2i R i) a. .
OREGON 4 ® 0 - ci lit). I
v0 `108/20 ��� E V i. f w - .
ti W. KE��y �� o. R' a co 33
R
.fres: 6/30/2019 a w- � >y C
John W. Kelly, P.E., S.E. nM
tnxTower Report version 8.0.5.0i
May 06, 2019
100 Ft Monopole Tower Structural Analysis CCI BU No 879602
Project Number 78702.004.01, Order 485007, Revision 0 Page 2
TABLE OF CONTENTS
1) INTRODUCTION
2)ANALYSIS CRITERIA
Table 1 -Proposed Equipment Configuration
Table 2 -Other Considered Equipment
3)ANALYSIS PROCEDURE
Table 3 -Documents Provided
3.1)Analysis Method
3.2)Assumptions
4)ANALYSIS RESULTS
Table 4 -Section Capacity (Summary)
Table 5—Tower Component Stresses vs. Capacity—LC5
4.1) Recommendations
5)APPENDIX A
tnxTower Output
6)APPENDIX B
Base Level Drawing
7)APPENDIX C
Additional Calculations
tnxTower Report-version 8.0.5.0
May 06, 2019
100 Ft Monopole Tower Structural Analysis CCI BU No 879602
Project Number 78702.004.01, Order 485007, Revision 0 Page 3
1) INTRODUCTION
This tower is a 100 ft. Monopole tower designed by Summit Manufacturing in April of 2001. The tower was
originally designed for a wind speed of 85 mph per TIA/EIA-222-F.
2)ANALYSIS CRITERIA
TIA-222 Revision: TIA-222-H
Risk Category: II
Wind Speed: 120 mph
Exposure Category: C
Topographic Factor: 1
Ice Thickness: 2 in
Wind Speed with Ice: 30 mph
Service Wind Speed: 60 mph
Table 1 -Proposed Equipment Configuration
Center Number Number Feed
Mounting Line Antenna
Level (ft) Elevation
of Manufacturer Antenna Model of Feed Line
(ft) Antennas Lines Size(in)
88.0 2 Nokia I TME-FXFB
87.0 r` -- -
I 87.0 I 1 ( -- I Side Arm Mount[SO 104-3]
6 Andrew TMBXX-6516-A2M
86.0 86.0
3 �Commscope FFHH-65C-R3
1 Commscope HCS 2.0 Part 1 18 7/8
- -- Nokia ------ AHFIG 1 5/8
3 Nokia AHLOA
1 I -- 1 T-Arm Mount[TA 602-3]
Table 2 -Other Considered Equipment
Center Number Number Feed
Mounting Line of Antenna Antenna Model of Feed Line
Level (ft) Elevation Antennas Manufacturer Lines Size(in)
(ft)
3 KMW ET-X-WM-18-65-8P
1 RFS Celwave I APXVERR18-C
100.0 -i---- --RFS CelwaveAPXVSPP18-C-A20
3 Samsung Tele 2.5GHz RRH-V3
3 Samsung Tele Power Junction Cylinder
99.0
— 3 1-1/4
3 ilmuiarnsung Tele 4_RRH C2A W/Ext Film.-
99.0 •
3 Samsung Tele RRH-P4
1 -- I Miscellaneous [NA 510-1]
1 -- ! Platform Mount[LP 1201-1]
96.0 1 -- I Miscellaneous [NA 509-3]
tnxTower Report-version 8.0.5.0
May 06, 2019
100 Ft Monopole Tower Structural Analysis CCI BU No 879602
Project Number 78702.004.01, Order 485007, Revision 0 Page 4
3)ANALYSIS PROCEDURE
Table 3-Documents Provided
Document Remarks Reference Source .
Online Order Information T-Mobile Co-Locate, Rev#0 l 485007 ,CCI Sites
Tower Manufacturer Drawing Summit Manufacturing, Job No. 13655 1 1625431 ,CCI Sites
Mount Analysis T-Squad Site Services, Report Desig.n:879602 Date: 05/01/20191 On-File
Foundation Drawing Summit Manufacturing, Job No. 13655 1486071 CCI Sites
:
r Geotech Report ADaPT Engineering Inc., 1574203 CCI Sites.
Project No. OR00-5310 i
7 Antenna Configuration I Crown CAD Package Date: 05/02/2019!CCI Sites,
3.1) Analysis Method
tnxTower (version 8.0.5.0), a commercially available analysis software package, was used to create a
three-dimensional model of the tower and calculate member stresses for various loading cases.
Selected output from the analysis is included in Appendix A.
3.2) Assumptions
1) The tower and structures were built and have been maintained in accordance with the
manufacturer's specification.
2) The configuration of antennas, transmission cables, mounts and other appurtenances are as
specified in Tables 1 and 2 and the referenced drawings.
3) Mount areas and weights are assumed based on photographs provided.
This analysis may be affected if any assumptions are not valid or have been made in error. B+T .
Group should be notified to determine the effect on the structural integrity of the tower.
4)ANALYSIS RESULTS
Table 4-Section Capacity (Summary)
Section Component Critical K SF*P_allow % pass/Fail
No. Elevation(ft) Type Size Element ( ) (K) Capacity
100-72.75 Pole TP26.088x22x0.188 1 -8.480 928.984 30.8 Pass l
L1 L2 i 72.75 36 - Pole ' TP31.227x25.225x0.219 : 2 -12.060 • 1296 844 63.6 - Pass
I L 3 36-0 Pole TP36.19x30.189x0.25 3 -17.614 1751.746 j 78_7 Pass
{ Summary
Pole(L3) 78.7 Pass
Rating= 78.7 Pass
tnxTower Report-version 8.0.5.0
May 06, 2019
100 Ft Monopole Tower Structural Analysis CCI BU No 879602
Project Number 78702.004.01, Order 485007, Revision 0 Page 5
Table 5-Tower Component Stresses vs. Capacity—LC5
Notes Component Elevation (ft) % Capacity Pass/Fail
1 Anchor Rods Base 63.4 Pass
1 Base Plate Base 60.2 Pass
1 Base Foundation (Structure) Base 34.0 Pass
1 Base Foundation (Soil Interaction) Base 36.9 Pass
Structure Rating (max from all components)= 78.7%
Notes:
1) See additional documentation in"Appendix C—Additional Calculations"for calculations supporting the%capacity
consumed.
2) Rating per TIA-222-H Section 15.5
4.1) Recommendations
The tower and its foundations have sufficient capacity to carry the proposed load configuration. No
modifications are required at this time.
tnxTower Report-version 8.0.5.0
APPENDIX A
TNXTOWER OUTPUT
I
100011 I
MATERIAL STRENGTH
GRADE Fy Fu GRADE I Fy 1 Fu
A607-65 65 ksi 80 ksi
TOWER DESIGN NOTES
i , 1. Tower is located in Washington County,Oregon.
8 ■,r.> 2. Tower designed for Exposure C to the TIA-222-H Standard.
`O `O 8 8 W I 11 d 3. Tower designed for a 120 mph basic wind in accordance with the TIA-222-H Standard.
o w N 4 Jfg 4. Tower is also designed for a 30 mph basic wind with 2.00 in ice.Ice is considered to increase
f in thickness with height.
5. Deflections are based upon a 60 mph wind.
6. Tower Risk Category II.
7. Topographic Category 1 with Crest Height of 0.000 ft
8. TIA-222-H Annex S
9 TOWER RATING:78.7%
/ 72.8 ft
0
0
V V N N N
N s N ,,, ^
N
O N M ,C
Q 0
/
- 36.0 ft
ALL REACTIONS
ARE FACTORED
AXIAL
8o 2 o 36K
SHEAR MOMENT
2 K ( , 130 kip-ft
TORQUE 0 kip-ft
30 mph WIND-2.000 in ICE
AXIAL
18K
SHEAR MOMENT
15 1
15 K r 1121 kip-ft
0.0 ft
TORQUE 1 kip-ft
- m
REACTIONS-120 mph WIND
`o - y
5E v 3 O o c of
v) i z' H (,) H m° o 3
B+T Group °b:78702.004.01-BARROWS RD, OR(BU#879602
1717 S. Boulder, Suite 300 Project:
g•T GWP Tulsa, OK 74119 Client. Crown Castle Drawn by.Rakshak App'd:
Phone:(918)587-4630 Code TIA-222-H Date:05/03/19 Scale: NTS
FAX:(918)295-0265 Path Dwg No.E-1
TIA-222-H - 120 mph/30 mph 2.000 in Ice Exposure C Maximum Values
Vx Vz Mx Mz
Global Mast Shear (K) Global Mast Moment(kip-ft)
0 5 10 15 0 500 1000 1500
100.00100.000
1 1 I 1
I
q 72.750
72.75 ___._+__ _+____+____ _a__. _�____ ____a____+____+___._+ .__
I
1
1
I I
C
O
RS
W
36.00q
36.000
�
I
I
/„I
I
1
0.005 0.000
0 5 10 15 0 500 1000 1500
Job:
B+T Group 78702.004.01-BARROWS RD, OR(BU#879602
1717 S. Boulder, Suite 300 Project:
client Crown Castle Drawn by:Rakshak Appd:
B.T Tulsa, OK 74119
Phone:(918)587-4630 code: TIA-222-H Date:05/03/19 Scale: NTS
FAX:(918)295-0265Dw No E-4
Path. 9
, TIA-222-H - Service -60 mph Maximum Values
Deflection (in) Tilt(deg) Twist (deg)
0 5 10 15 0 0-5 1 1.5 0 005 0-1 _—
ioo.00d 100.000
I I I II I I I I I
1 I I I I I I I
I I I I I I I I
I I I I I I I I I
I I I I I I I I
I I I I I I I I I
I I I I I I I I I
I I I I I I I I I I
I I I I I I I I I I
I I 1 I I I I I I I I
I I I I I I I I I I
I I I I I I I I I I I
I I I I I I I I I
I I I I I I I I I
= 4 I I I I 72.750
I I I I I I II
I I I I I I I I I I I
I I I I I I I I I I I I I I I
I I I I I I I I I I
I I I I I I I I I I I I I I
I I I I I I I I I
I I I I I I I I I I
I I I I I I I I I I
I I I I I I I I I I
I I I I I I I I I
I I I I I I II
I I 1 I I 1 I I I 11 I I I I I I I I I
= I I 1 I I 1 1 I I 1 I I I I I 1 1 I I
O 1 1 1 I I 1 1 I I 1 I 1 I I 1 I 1 I
CIS 1 1 1 1t I 1 f 11 1 , - I 1 I I I t I I
> I I 1 I I I I I I I I 1 I I I 1 I
1 I 1 1 I 1 I 1 I I 1
W- I I I I I I I I I I I I I
I I I I I I I 1 I I I I I I
I I I I I I I I I I
I I I 1 1 I I I I I
36.000 I I I I I I I 36.000
I I I 1 1 1 1 I I I 1 1
1 1 I 1 1 1 1 I 1 1 1
1 1 I 1 1 1 1 1 I 1 1
1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1
--rte _r
1 I I I I I I I I I 1 1 I I I
1 1 1 1 1 1
1 I I 1 1 1 1
' ' 1 1I I I 11 I I __ I I I I
I ' I T I t I 1 t t T t ___ I 1 I I I I I
,
1 1 1 1 I 1 I 1 1 1
' ' 1 1 1 1 1 1 1 I 1 1 1
1 1 1 1 1 1 1 1 1 1 1
' 1 1 I I 1 1 1 1 1 1 I I 1 1 1 1 1 1
' 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 I 1 1 1 1 1 1 1 I 1 1 1 1 1
1 1 I 1 1 1 1 1 1 1 I 1 1 1 1 1
0.000 , , , t i I 1 1 I I 1 I I 0.000
0 5 10 15 0 0.5 1 1.5 0 0.05 0.1
B+T Group °b 78702.004.01-BARROWS RD, OR(BU#879602
��
1717 S. Boulder, Suite 300 Project:
6.T GRP Tulsa, OK 74119 O11ent: Crown Castle Drawn by:Rakshak Appd:
Phone:(918)587-4630 Code: TIA-222-H Date:05/03/19 Scale: NTS
FAX:(918)295-0265 Path: Dwg No.E-5
Feed Line Distribution Chart
0' - 100'
Round Flat App In Face App Out Face Truss Leg
Face A Face B Face C
100.000 100.000
99.000 99.000
86.000 86.000
75.000 75.000
72.750 72750
v w
w
=
0 \
47, OC _
> LL °' LIT a
CD o N
W _ r.:::. `
r
o a_
O of N
I
o
36.000 36.000
o0
O
m
0
a
0.000 o:000
d- B+T Group job:78702.004.01-BARROWS RD, OR(BU#879602
1717 S. Boulder, Suite 300 Project
E.T Tulsa, OK 74119 Client Crown Castle Drawn by:Rakshak Appd.
Phone:(918)587-4630 Code: TIA-222-H Date:05/03/19 Sale: NTS
FAX:(918)295-0265 Path: Dwg No.E-7
Job Page
tnxTower 78702.004.01 - BARROWS RD, OR (BU#879602) 1 of 15
B+T Group Project Date
1717 S.Boulder,Suite 300 17:07:09 05/03/19
Tulsa,OK 74119 Client Designed by
• Phone:(918)587-4630 Crown Castle
FAX:(918)295-0265 Rakshak
Tower Input Data
The tower is a monopole.
This tower is designed using the TIA-222-H standard.
The following design criteria apply:
Tower is located in Washington County,Oregon.
Tower base elevation above sea level:313.000 ft.
Basic wind speed of 120 mph.
Risk Category II.
Exposure Category C.
Simplified Topographic Factor Procedure for wind speed-up calculations is used.
Topographic Category: 1.
Crest Height:0.000 ft.
Nominal ice thickness of 2.000 in.
Ice thickness is considered to increase with height.
Ice density of 56.000 pcf.
A wind speed of 30 mph is used in combination with ice.
Temperature drop of 50.000°F.
Deflections calculated using a wind speed of 60 mph.
TIA-222-H Annex S.
A non-linear(P-delta)analysis was used.
Pressures are calculated at each section.
Stress ratio used in pole design is 1.05.
Tower analysis based on target reliabilities in accordance with Annex S.
Load Modification Factors used:Kes(Fw)=0.95,Kes(ti)=0.85.
Local bending stresses due to climbing loads,feed line supports,and appurtenance mounts are not considered.
Options
Consider Moments-Legs Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules
Consider Moments-Horizontals Assume Legs Pinned Calculate Redundant Bracing Forces
Consider Moments-Diagonals ' Assume Rigid Index Plate -ignore Redundant Members in FEA
Use Moment Magnification ) Use Clear Spans For Wind Area SR Leg Bolts Resist Compression
Use Code Stress Ratios Use Clear Spans For KL/r All Leg Panels Have Same Allowable
Ai Use Code Safety Factors-Guys Retension Guys To Initial Tension Offset Girt At Foundation
Escalate Ice Bypass Mast Stability Checks ) Consider Feed Line Torque
Always Use Ms - Al Use Azimuth Dish CoefficietlLs : uclude Angle BIGGIc cr.e.,.Ci,eck _- _
Use Special Wind Profile ) Project Wind Area of Appurt. Use TIA-222-H Bracing Resist.Exemption
Include Bolts In Member Capacity Autocalc Torque Arm Areas Use TIA-222-H Tension Splice Exemption
Leg Bolts Are At Top Of Section Add IBC.6D+W Combination Poles
Secondary Horizontal Braces Leg Sort Capacity Reports By Component - Include Shear-Torsion Interaction
Use Diamond Inner Bracing(4 Sided) Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow
SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets
SR Members Are Concentric Ignore KL/ry For 60 Deg.Angle Legs Pole Without Linear Attachments
•
Pole With Shroud Or No Appurtenances
Outside and Inside Corner Radii Are
Known
Job Page
tnxTower 78702.004.01 - BARROWS RD, OR (BU#879602) 2 of 15
B+T Group Project Date
1717 S.Boulder,Suite 300 17:07:09 05/03/19
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle Rakshak
FAX:(918)295-0265
Tapered Pole Section Geometry
Section Elevation Section Splice Number Top Bottom Wall Bend Pole Grade
Length Length of Diameter Diameter Thickness Radius
ft ft ft Sides in in in in
Ll 100.000-72.750 27.250 3.250 18 22.000 26.088 0.188 0.750 A607-65
(65 ksi)
L2 72.750-36.000 40.000 4.000 18 25.225 31.227 0.219 0.875 A607-65
(65 ksi)
L3 36.000-0.000 40.000 18 30.189 36.190 0.250 1.000 A607-65
(65 ksi)
Tapered Pole Properties
Section Tip Dia. Area I r C I/C J It/Q w w/t
in in' in' in in in3 in' in' in
Ll 22.310 12.981 780.301 7.743 11.176 69.819 1561.628 6.492 3.542 18.891
26.462 15.414 1306.382 9.195 13.253 98.575 2614.482 7.708 4.261 22.728
L2 26.076 17.362 1371.706 8.877 12.815 107.043 2745.217 8.683 4.055 18.536
31.675 21.529 2615.316 11.008 15.863 164.866 5234.074 10.767 5.111 23.364
L3 31.226 23.757 2690.365 10.628 15.336 175.426 5384.270 11.881 4.873 19.493
36.710 28.518 4653.917 12.759 18.385 253.143 9313.957 14.262 5.929 23.718
Tower Gusset Gusset Gusset Grade Adjust.Factor Adjust. Weight Mult. Double Angle Double Angle Double Angle
Elevation Area Thickness Af Factor Stitch Bolt Stitch Bolt Stitch Bolt -
(per face) A, Spacing Spacing Spacing
Diagonals Horizontals Redundants
ft ft' in in in in
L1 1 1 I
100.000-72.75
0
L2 1 1 1
72.750-36.000
L3 1 1 1
36.000-0.000
Feed Line/Linear Appurtenances - Entered As Round Or Flat
Description Sector Exclude Component Placement Total Number Start/End Width or Perimeter Weight
From Type Number Per Row Position Diameter
Torque ft in in klf
Calculation
ATCB-B01-001(5/16") A No Surface Ar 75.000- 1 1 -0.450 0.315 0.000
(E-Ground) (CaAa) 0.000 -0.450
***
Safety Line 3/8 A No Surface Ar 100.000- 1 1 0.490 0.375 0.000
(E) (CaAa) 0.000 0.490
***
Feed Line/Linear Appurtenances - Entered As Area
Job ob Page
78702.004.01 - BARROWS RD, OR (BU# 879602) 3 of 15
B+T Group Project Date
1717 S.Boulder,Suite 300 17:07:09 05/03/19
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle Rakshak
FAX. (918)295-0265
Description Face Allow Exclude Component Placement Total CAAA Weight
or Shield From Type Number
Leg Torque ft ft2/ft klf
Calculation
LDF6-50A(1-1/4) A No No Inside Pole 99.000-0.000 3 No Ice 0.000 0.001
(E) 1/2"Ice 0.000 0.001
1"Ice 0.000 0.001
2"Ice 0.000 0.001
LDF5-50A(7/8) C No No Inside Pole 86.000-0.000 18 No Ice 0.000 0.000
(E) 1/2"Ice 0.000 0.000
1"Ice 0.000 0.000
2"Ice 0.000 0.000
HCS 2.0 Part 2(5/8) C No No Inside Pole 86.000-0.000 1 No Ice 0.000 0.000
(P) 1/2"Ice 0.000 0.000
1"Ice 0.000 0.000
2"Ice 0.000 0.000
***
Feed Line/Linear Appurtenances Section Areas
Tower Tower Face AR AF CAAA CAAA Weight
Section Elevation In Face Out Face
ft ft2 ft2 ft2 ft2 K
Ll 100.000-72.750 A 0.000 0.000 1.093 0.000 0.053
B 0.000 0.000 0.000 0.000 0.000
C 0.000 0.000 0.000 0.000 0.083
L2 72.750-36.000 A 0.000 0.000 2.536 0.000 0.077
B 0.000 0.000 0.000 0.000 0.000
C 0.000 0.000 0.000 0.000 0.231
L3 36.000-0.000 A 0.000 0.000 2.484 0.000 0.075
B 0.000 0.000 0.000 0.000 0.000
C 0.000 0.000 0.000 0.000 0.226
Feed Line/Linear Appurtenances Section Areas - With Ice
Tower Tower Face Ice AR AF CAAA CAAA Weight
Section Elevation or Thickness In Face Out Face
ft Leg in ft2 ft2 ft2 ft2 K
LI 100.000-72.750 A 1.871 0.000 0.000 12.131 0.000 0.205
B 0.000 0.000 0.000 0.000 0.000
C 0.000 0.000 0.000 0.000 0.083
L2 72.750-36.000 A 1.786 0.000 0.000 30.037 0.000 0.449
B 0.000 0.000 0.000 0.000 0.000
C 0.000 0.000 0.000 0.000 0.231
L3 36.000-0.000 A 1.601 0.000 0.000 28.205 0.000 0.410
B 0.000 0.000 0.000 0.000 0.000
C 0.000 0.000 0.000 0.000 0.226
Feed Line Center of Pressure
Job Page
tnxTower 78702.004.01 - BARROWS RD, OR (BU#879602) 4 of 15
B+T Group Project Date
1717 S.Boulder,Suite 300 17:07:09 05/03/19
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle Rakshak
FAX.:(918)295-0265
Section Elevation CPx CPz CPx CPz
Ice Ice
ft in in in in
L1 100.000-72.750 -0.027 -0.291 -0.156 -1.488
L2 72.750-36.000 -0.233 -0.195 -1.338 -0.873
L3 36.000-0.000 -0.234 -0.196 -1.354 -0.884
Note:For pole sections,center of pressure calculations do not consider feed line shielding.
Shielding Factor Ka
Tower Feed Line Description Feed Line K K
Section Record No. Segment Elev. No Ice Ice
LI 7 ATCB-B01-001(5/16") 72.75-75.00 1.0000 1.0000
Ll 9 Safety Line 3/8 72.75-100.00 1.0000 1.0000
L2 7 ATCB-B01-001(5/16") 36.00-72.75 1.0000 1.0000
L2 9 Safety Line 3/8 36.00-72.75 1.0000 1.0000
Discrete Tower Loads
Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight
or Type Horz Adjustment Front Side
Leg Lateral
Vert
ft ° ft ft2 ft2 K
ft
ft
Top Hat C None 0.000 101.000 No Ice 3.000 3.000 0.081
(E) 1/2"Ice 3.480 3.480 0.111
1"Ice 3.960 3.960 0.141
2"Ice 4.920 4.920 0.201
***
APXVSPP18-C-A20 w/ A From Leg 4.000 0.000 99.000 No Ice 4.600 4.010 0.088
Mount Pipe 0.000 1/2"Ice 5.050 4.450 0.152
(E) 1.000 1"Ice 5.500 4.890 0.227
2"Ice 6.440 5.820 0.412
APXVSPP18-C-A20 w/ B From Leg 4.000 0.000 99.000 No Ice 4.600 4.010 0.088
Mount Pipe 0.000 1/2"Ice 5.050 4.450 0.152
(E) 1.000 1"Ice 5.500 4.890 0.227
2"Ice 6.440 5.820 0.412
APXVERR18-C w/Mount C From Leg 4.000 0.000 99.000 No Ice 8.262 6.946 0.076
Pipe 0.000 1/2"Ice 8.822 8.127 0.144 _
(E) 1.000 1"Ice 9.346 9.021 0.220
2"Ice 10.418 10.844 0.399
ET-X-WM-18-65-8P w/ A From Leg 4.000 0.000 99.000 No Ice 4.000 2.300 0.059
Mount Pipe 0.000 1/2"Ice 4.390 2.660 0.106 -
(E) 1.000 I"Ice 4.790 3.030 0.162
2"Ice 5.620 3.800 0.305
ET-X-WM-18-65-8P w/ B From Leg 4.000 0.000 99.000 No Ice 4.000 2.300 0.059
Job Page
tnxTower 78702.004.01 - BARROWS RD, OR (BU#879602) 5 of 15
B+T Group Project Date
1717 S.Boulder,Suite 300 17:07:09 05/03/19
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle
FAX::(918)295-0265 Rakshak
Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight
or Type Horz Adjustment Front Side
Leg Lateral
Vert
ft ft ft2 ft2 K
ft
ft
Mount Pipe 0.000 1/2"Ice 4.390 2.660 0.106
(E) 1.000 1"Ice 4.790 3.030 0.162
2"Ice 5.620 3.800 0.305
ET-X-WM-18-65-8P w/ C From Leg 4.000 0.000 99.000 No Ice 4.000 2.300 0.059
Mount Pipe 0.000 1/2"Ice 4.390 2.660 0.106
(E) 1.000 1"Ice 4.790 3.030 0.162
2"Ice 5.620 3.800 0.305
RRH-P4 A From Leg 4.000 0.000 99.000 No Ice 2.735 1.789 0.060
(E) 0.000 1/2"Ice 2.948 1.968 0.083
0.000 1"Ice 3.168 2.158 0.109
2"Ice 3.630 2.566 0.172
RRH-P4 B From Leg 4.000 0.000 99.000 No Ice 2.735 1.789 0.060
(E) 0.000 1/2"Ice 2.948 1.968 0.083
0.000 1"Ice 3.168 2.158 0.109
2"Ice 3.630 2.566 0.172
RRH-P4 C From Leg 4.000 0.000 99.000 No Ice 2.735 1.789 0.060
(E) 0.000 1/2"Ice 2.948 1.968 0.083
0.000 1"Ice 3.168 2.158 0.109
2"Ice 3.630 2.566 0.172
RRH-C2A W/EXT FILTER A From Leg 4.000 0.000 99.000 No Icc 3.109 1.379 0.055
• (E) 0.000 1/2"Ice 3.332 1.545 0.077
0.000 1"Ice 3.562 1.719 0.103
2"Ice 4.045 2.087 0.164
RRH-C2A W/EXT FILTER B From Leg 4.000 0.000 99.000 No Ice 3.109 1.379 0.055
(E) 0.000 1/2"Ice 3.332 1.545 0.077
0.000 1"Ice 3.562 1.719 0.103
2"Ice 4.045 2.087 0.164
RRH-C2A W/EXT FILTER C From Leg 4.000 0.000 99.000 No Ice 3.109 1.379 0.055
(E) 0.000 1/2"Ice 3.332 1.545 0.077
0.000 1"Ice 3.562 1.719 0.103
2"Ice 4.045 2.087 0.164
POWER JUNCTION A From Leg 4.000 0.000 99.000 No Ice 0.369 0.369 0.003
CYLINDER 0.000 1/2"Ice 0.453 0.453 0.007
(E) 1.000 1"Ice 0.547 0.547 0.013
2"Ice 0.758 0.758 0.029
POWER JUNCTION B From Leg 4.000 0.000 99.000 No Ice 0.369 0.369 0.003
CYLINDER 0.000 1/2"Ice 0.453 0.453 0 007
(E) 1.000 1"Ice 0.547 0.547 0.013
2"Ice 0.758 0.758 0.029
„ POWER JUNCTION C From Leg 4.000 0.000 99.000 No Ice 0.369 0.369 0.003
CYLINDER 0.000 1/2"Ice 0.453 0.453 0.007
. (P lielea 1"Ice 0.547 0.547 O:0I3
2"Ice 0.758 0.758 0.029
2.5GHz RRH-V3 A From Leg 4.000 0.000 99.000 No Ice 2.402 1.221 0.060
(E) 0.000 1/2"Ice 2.596 1.363 0.081
1.000 1"Ice 2.796 1.513 0.105
2"Ice 3.220 1.834 0.163
2.5GHz RRH-V3 B From Leg 4.000 0.000 99.000 No Ice 2.402 1.221 0.060
(E) 0.000 1/2"Ice 2.596 1.363 0.081
1.000 1"Ice 2.796 1.513 0.105
2"Ice 3.220 1.834 0.163
2.5GHz RRH-V3 C From Leg 4.000 0.000 99.000 No Ice 2.402 1.221 0.060
(E) 0.000 1/2"Ice 2.596 1.363 0.081
- 1.000 1"Ice 2.796 1.513 0.105
2"Ice 3.220 1.834 0.163
(2)6'x 2"Mount Pipe A From Leg 4.000 0.000 99.000 No Ice 1.425 1.425 0.022
(E) 0.000 1/2"Ice 1.925 1.925 0.033
Job Page
tnxTower 78702.004.01 - BARROWS RD, OR (BU#879602) 6 of 15
B+T Group Project Date
1717 S Boulder,Suite 300 17:07:09 05/03/19
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle
Rakshak
FAX:(918)295-0265
Description Face Offset Offsets: Azimuth Placement CAAA CAAA
Weight
or Type Horz Adjustment Front Side
Leg Lateral
Vert
ft ° ft ft2 ft2 K
ft
ft
0.000 1"Ice 2.294 2.294 0.048
2"Ice 3.060 3.060 0.090
(2)6'x 2"Mount Pipe B From Leg 4.000 0.000 99.000 No Ice 1.425 1.425 0.022
(E) 0.000 1/2"Ice 1.925 1.925 0.033
0.000 1"Ice 2.294 2.294 0.048
2"Ice 3.060 3.060 0.090
(2)6'x 2"Mount Pipe C From Leg 4.000 0.000 99.000 No Ice 1.425 1.425 0.022
(E) 0.000 1/2"Ice 1.925 1.925 0.033
0.000 1"Ice 2.294 2.294 0.048
2"Ice 3.060 3.060 0.090
Miscellaneous[NA 509-3] C None 0.000 96.000 No Ice 11.840 11.840 0.275
(E) 1/2"Ice 16.960 16.960 0.296
1"Ice 22.080 22.080 0.317
2"Ice 32.320 32.320 0.360
Miscellaneous[NA 510-1] C None 0.000 99.000 No Ice 6.000 6.000 0.256
(E) 1/2"Ice 8.500 8.500 0.340
1"Ice 11.000 11.000 0.423
2"Ice 16.000 16.000 0.591
Platform Mount[LP 1201-1] C None 0.000 99.000 No Ice 23.100 23.100 2.100
(E) 1/2"Ice 26.800 26.800 2.500
1"Ice 30.500 30.500 2.900 •
2"Ice 37.900 37.900 3.700
***
(2)TME-FXFB C From Leg 2.000 0.000 87.000 No Ice 3.538 1.023 0.055
(E) 0.000 1/2"Ice 3.771 1.173 0.077
1.000 1"Ice 4.012 1.330 0.103
2"Ice 4.515 1.664 0.164
6'x 2"Mount Pipe B From Leg 2.000 0.000 87.000 No Ice 1.425 1.425 0.022
(E) 0.000 1/2"Ice 1.925 1.925 0.033
0.000 1"Ice 2.294 2.294 0.048
2"Ice 3.060 3.060 0.090
6'x 2"Mount Pipe C From Leg 2.000 0.000 87.000 No Ice 1.425 1.425 0.022
(E) 0.000 1/2"Ice 1.925 1.925 0.033
0.000 1"Ice 2.294 2.294 0.048
2"Ice 3.060 3.060 0.090
Side Arm Mount[SO 104-3] C None 0.000 87.000 No Ice 3.300 3.300 0.287
- (E) 1/2"Ice 4.130 4.130 0.317
1"Ice 4.960 4.960 0.347
2"Ice 6.620 6.620 0.407
(2)TMBXX-6516-A2M w/ A From Leg 4.000 0.000 86.000 No Ice 5.656 4.525 0.054
Mount Pipe 0.000 1/2"Ice 6.064 5.205 0.103
(E) 0.000 1"Ice 6.475 5.857 0.158
2"Ice 7.322 7.198 0.291
(2)TMBXX-6516-A2M w/ B From Leg 4.000 0.000 86.000 No Ice 5.656 4.525 0.054
Mount Pipe 0.000 1/2"Ice 6.064 5.205 0.103
(E) 0.000 1"Ice 6.475 5.857 0.158
2"Ice 7.322 7.198 0.291
(2)TMBXX-6516-A2M w/ C From Leg 4.000 0.000 86.000 No Ice 5.656 4.525 0.054
Mount Pipe 0.000 1/2"Ice 6.064 5.205 0.103 -
(E) 0.000 1"Ice 6.475 5.857 0.158
2"Ice 7.322 7.198 0.291
FFHH-65C-R3 w/Mount A From Leg 4.000 0.000 86.000 No Ice 12.970 6.200 0.161
Pipe 0.000 1/2"Ice 13.620 6.770 0.296 -
(P) 0.000 1"Ice 14.270 7.360 0.445
2"Ice 15.620 8.570 0.790
FFHH-65C-R3 w/Mount B From Leg 4.000 0.000 86.000 No Ice 12.970 6.200 0.161
Job Page
tnxTower 78702.004.01 - BARROWS RD, OR (BU#879602) 7 of 15
B+T Group Project Date
1717 S.Boulder,Suite 300 17:07:09 05/03/19
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle
FAX:(918)295-0265 Rakshak
Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight
or Type Horz Adjustment Front Side
Leg Lateral
Vert
ft ft ft' ft' K
ft
ft
Pipe 0.000 1/2"Ice 13.620 6.770 0.296
(P) 0.000 1"Ice 14.270 7.360 0.445
2"Ice 15.620 8.570 0.790
FFHH-65C-R3 w/Mount C From Leg 4.000 0.000 86.000 No Ice 12.970 6.200 0.161
Pipe 0.000 1/2"Ice 13.620 6.770 0.296
(P) 0.000 1"Ice 14.270 7.360 0.445
2"Ice 15.620 8.570 0.790
HCS 2.0 Part 1 A From Leg 4.000 0.000 86.000 No Ice 1.867 0.933 0.024
(P) 0.000 1/2"Ice 2.037 1.059 0.040
0.000 1"Ice 2.215 1.193 0.059
2"Ice 2.593 1.481 0.105
AHFIG A From Leg 4.000 0.000 86.000 No Ice 3.082 1.404 0.079
(P) 0.000 1/2"Ice 3.313 1.586 0.100
0.000 1"Ice 3.552 1.775 0.125
2"Ice 4.052 2.175 0.183
AHFIG B From Leg 4.000 0.000 86.000 No Ice 3.082 1.404 0.079
(P) 0.000 1/2"Ice 3.313 1.586 0.100
0.000 1"Ice 3.552 1.775 0.125
2"Ice 4.052 2.175 0.183
AHFIG C From Leg 4.000 0.000 86.000 No Ice 3.082 1.404 0.079
(P) 0.000 1/2"Ice 3.313 1.586 0.100
0.000 1"Ice 3.552 1.775 0.125
2"Ice 4.052 2.175 0.183
AHLOA A From Leg 4.000 0.000 86.000 No Ice 2.229 1.391 0.084
(P) 0.000 1/2"Ice 2.422 1.552 0.102
0.000 1"Ice 2.623 1.720 0.123
2"Ice 3.048 2.082 0.175
AHLOA B From Leg 4.000 0.000 86.000 No Ice 2.229 1.391 0.084
(P) 0.000 1/2"Ice 2.422 1.552 0.102
0.000 1"Ice 2.623 1.720 0.123
2"Ice 3.048 2.082 0.175
AHLOA C From Leg 4.000 0.000 86.000 No Ice 2.229 1.391 0.084
(P) 0.000 1/2"Ice 2.422 1.552 0.102
0.000 1"Ice 2.623 1.720 0.123
2"Ice 3.048 2.082 0.175
5'x 2"Pipe Mount A Prom Leg 4.000 0.000 86.000 No Ice 1.000 1.000 0.029
(E) 0.000 1/2"Ice 1.393 1.393 0.037
0.000 1"Ice 1.703 1.703 0.048
2"Ice 2.351 2.351 0.082
5'x 2"Pipe Mount B From Leg 4.000 0.000 86.000 No Ice 1.000 1.000 0.029
(E) 0.000 1/2"Ice 1.393 1.393 0.037
(Iona 1"Ice 1.703 1.703 0.048 .
2"Ice 2.351 2.351 0.082
5'x 2"Pipe Mount C From Leg 4.000 0.000 86.000 No Ice 1.000 1.000 0.029
(E) 0.000 1/2"Ice 1.393 1.393 0.037
0.000 1"Ice 1.703 1.703 0.048
2"Ice 2.351 2.351 0.082
T-Arm Mount[TA 602-3] C None 0.000 86.000 No Ice 11.590 11.590 0.774
(E) 1/2"Ice 15.440 15.440 0.990
•
1"Ice 19.290 19.290 1.206
2"Ice 26.990 26.990 1.639
*0*
Job Page
tnxTower 78702.004.01 - BARROWS RD, OR (BU#879602) 8 of 15
B+T Group Project Date
1717 S.Boulder,Suite 300 17:07:09 05/03/19
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle
FAX:(918)295-0265 Rakshak
Load Combinations
Comb. Description
No.
1 Dead Only
2 1.2 Dead+1.O Wind O deg-No Ice
3 0.9Dead+1.OWind Odeg-No Ice
4 1.2 Dead+1.0 Wind 30 deg-No Ice
5 0.9 Dead+1.0 Wind 30 deg-No Ice
6 1.2 Dead+1.0 Wind 60 deg-No Ice
7 0.9 Dead+1.0 Wind 60 deg-No Ice
8 1.2 Dead+1.0 Wind 90 deg-No Ice
9 0.9 Dead+1.0 Wind 90 deg-No Ice
10 1.2 Dead+1.0 Wind 120 deg-No Ice
11 0.9 Dead+1.0 Wind 120 deg-No Ice
12 1.2 Dead+1.0 Wind 150 deg-No Ice
13 0.9 Dead+1.0 Wind 150 deg-No Ice
14 1.2 Dead+1.0 Wind 180 deg-No Ice
15 0.9 Dead+1.0 Wind 180 deg-No Ice
16 1.2 Dead+1.0 Wind 210 deg-No Ice
17 0.9 Dead+1.0 Wind 210 deg-No Ice
18 1.2 Dead+1.0 Wind 240 deg-No Ice
19 0.9 Dead+1.0 Wind 240 deg-No Ice
20 1.2 Dead+1.0 Wind 270 deg-No Ice
21 0.9 Dead+1.0 Wind 270 deg-No Ice
22 1.2 Dead+1.0 Wind 300 deg-No Ice
23 0.9 Dead+1.0 Wind 300 deg-No Ice
24 1.2 Dead+1.0 Wind 330 deg-No Ice
25 0.9 Dead+1.0 Wind 330 deg-No Ice
26 1.2 Dead+1.0 Ice+1.0 Temp
27 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp
28 1.2 Dead+1.0 Wind 30 deg+1.0 Ice+1.0 Temp
29 1.2 Dead+1.0 Wind 60 deg+1.0 Ice+1.0 Temp
30 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp
31 1.2 Dead+1.0 Wind 120 deg+1.0 Ice+1.0 Temp
32 1.2 Dead+1.0 Wind 150 deg+1.0 Ice+1.0 Temp
33 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp
34 1.2 Dead+1.0 Wind 210 deg+1.0 Ice+1.0 Temp
35 1.2 Dead+1.0 Wind 240 deg+1.0 Ice+1.0 Temp
36 1.2 Dead+1.0 Wind 270 deg+1.0 Ice+1.0 Temp
37 1.2 Dead+1.0 Wind 300 deg+1.0 Ice+1.0 Temp
38 1.2 Dead+1.0 Wind 330 deg+1.0 Ice+1.0 Temp
39 Dead+Wind 0 deg-Service
40 Dead+Wind 30 deg-Service
41 Dead+Wind 60 deg-Service
42 Dead+Wind 90 deg-Service
43 Dead+Wind 120 deg-Service
44 Dead+Wind 150 deg-Service
45 Dead+Wind 180 deg-Service
46 Dead+Wind 210 deg-Service
47 Dead+Wind 240 deg-Service
48 Dead+Wind 270 deg-Service
49 Dead+Wind 300 deg-Service
50 Dead+Wind 330 deg-Service
Maximum Member Forces
Job ob Page
78702.004.01 - BARROWS RD, OR (BU#879602) 9 of 15
B+T Group Project Date
1717 S.Boulder,Suite 300 17:07:09 05/03/19
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle
FAX(918)295-0265 Rakshak
Section Elevation Component Condition Gov. Axial Major Axis Minor Axis
No. ft Type Load Moment Moment
Comb. K kip ft kip ft
L1 100-72.75 Pole Max Tension 1 0.000 0.000 0.000
Max.Compression 26 -20.903 1.015 -0.142
Max.Mx 20 -8.489 163.814 -1.419
Max.My 14 -8.500 1.603 -162.438
Max.Vy 20 -10.072 163.814 -1.419
Max.Vx 14 9.996 1.603 -162.438
Max.Torque 25 0.881
L2 72.75-36 Pole Max Tension 1 0.000 0.000 0.000
Max.Compression 26 -27.228 1.512 0.083
Max.Mx 20 -12.066 570.395 -4.882
Max.My 14 -12.073 5.106 -566.271
Max.Vy 20 -12.472 570.395 -4.882
Max.Vx 14 12.397 5.106 -566.271
Max.Torque 25 0.796
L3 36-0 Pole Max Tension 1 0.000 0.000 0.000
Max.Compression 26 -35.663 1.980 0.353
Max.Mx 20 -17.614 1115.448 -8.605
Max.My 14 -17.615 8.861 -1108.350
Max.Vy 20 -14.663 1115.448 -8.605
Max.Vx 14 14.591 8.861 -1108.350
Max.Torque 25 0.793
Maximum Reactions
Location Condition Gov. Vertical Horizontal,X Horizontal,Z
Load K K K
Comb.
Pole Max.Vert 36 35.663 1.597 -0.004
Max.H. 20 17.631 14.643 -0.091
Max.Hz 2 17.631 -0.091 14.571
Max.M. 2 1108.181 -0.091 14.571
Max.M, 8 1114.758 -14.643 0.091
Max.Torsion 25 0.792 7.243 12.574
Min.Vert 13 13.223 -7.243 -12.574
Min.H. 8 17.631 -14.643 0.091
Min.Hz 14 17.631 0.091 -14.571
Min.M. 14 -1108.350 0.091 -14.571
Min.Mz 20 -1115.448 14.643 -0.091
Min.Torsion 13 -0.792 -7.243 -12.574
Tower Mast Reaction Summary
Load Vertical Shear Shear, Overturning Overturning Torque
Combination Moment,M, Moment,M,
K K K kip ft kip ft kip ft
Dead Only 14.692 0.000 0.000 0.065 0.266 0.000
1.2 Dead+1.0 Wind 0 deg-No 17.631 0.091 -14.571 -1108.181 -8.188 -0.694
Ice
0.9 Dead+1.0 Wind 0 deg-No 13.223 0.091 -14.571 -1095.329 -8.172 -0.696
Ice
1.2 Dead+1.0 Wind 30 deg-No 17.631 7.400 -12.664 -963.940 -564.593 -0.412
Ice
0.9 Dead+1.0 Wind 30 deg-No 13.223 7.400 -12.664 -952.761 -558.112 -0.412
Job Page
tnxTower 78702.004.01 - BARROWS RD, OR (BU#879602) 10 of 15
B+T Group Project Date
1717 S.Boulder,Suite 300 17:07:09 05/03(19
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle
FAX:(918)295-0265 Rakshak
Load Vertical Shear„ Shear, Overturning Overturning Torque
Combination Moment,M Moment,M,
K K K kip ft kip ft kip ft
Ice
1.2 Dead+1.0 Wind 60 deg-No 17.631 12.726 -7.364 -561.413 -969.617 -0.018
Ice
0.9 Dead+1.0 Wind 60 deg-No 13.223 12.726 -7.364 -554.908 -958.432 -0.017
Ice
1.2 Dead+1.0 Wind 90 deg-No 17.631 14.643 -0.091 -8.443 -1114.758 0.380
Ice
0.9 Dead+1.0 Wind 90 deg-No 13.223 14.643 -0.091 -8.360 -1101.894 0.383
Ice
1.2 Dead+1.0 Wind 120 deg- 17.631 12.636 7.207 546.833 -961.133 0.676
No Ice
0.9 Dead+1.0 Wind 120 deg- 13.223 12.636 7.207 540.465 -950.050 0.679
No Ice
1.2 Dead+1.0 Wind 150 deg- 17.631 7.243 12.574 955.620 -549.853 0.789
No Ice
0.9 Dead+1.0 Wind 150 deg- 13.223 7.243 12.574 944.499 -543.552 0.792
No Ice
1.2 Dead+1.0 Wind 180 deg- 17.631 -0.091 14.571 1108.350 8.861 0.690
No Ice
0.9 Dead+1.0 Wind 180 deg- 13.223 -0.091 14.571 1095.452 8.667 0.692
No Ice
1.2 Dead+1.0 Wind 210 deg- 17.631 -7.400 12.664 964.111 565.272 0.408
No Ice
0.9 Dead+1.0 Wind 210 deg- 13.223 -7.400 12.664 952.887 558.611 0.409
No Ice
1.2 Dead+1.0 Wind 240 deg- 17.631 -12.726 7.364 561.581 970.301 0.019
No Ice
0.9 Dead+1.0 Wind 240 deg- 13.223 -12.726 7.364 555.031 958.935 0.017 _
No Ice
1.2 Dead+1.0 Wind 270 deg- 17.631 -14.643 0.091 8.605 1115.448 -0.376
No Ice
0.9 Dead+1.0 Wind 270 deg- 13.223 -14.643 0.091 8.479 1102.398 -0.379
No Ice
1.2 Dead+1.0 Wind 300 deg- 17.631 -12.636 -7.207 -546.674 961.811 -0.672
No Ice
0.9 Dead+1.0 Wind 300 deg- 13.223 -12.636 -7.207 -540.348 950.549 -0.675
No Ice
1.2 Dead+1.0 Wind 330 deg- 17.631 -7.243 -12.574 -955.457 550.526 -0.789
No Ice
0.9 Dead+1.0 Wind 330 deg- 13.223 -7.243 -12.574 -944.380 544.047 -0.792
No Ice
1.2 Dead+1.0 Ice+1.0 Temp 35.663 -0.000 -0.000 -0.353 1.980 0.000
1.2 Dead+1.0 Wind 0 deg+1.0 35.663 0.004 -1.594 -127.577 1.631 -0.071
Ice+1.0 Temp
1.2 Dead+1.0 Wind 30 deg+1.0 35.663 0.802 -1.383 -110.740 -62.043 -0.041
Ice+1.0 Temp
1.2 Dead+1.0 Wind 60 deg+1.0 35.663 1.385 -0.801 -64.329 -108.544 0.001
Ice+1.0 Temp
1.2 Dead+1.0 Wind 90 deg+1.0 35.663 1.597 -0.004 -0.777 -125.414 0.042
Ice+1.0 Temp
1.2 Dead+1.0 Wind 120 35.663 1.380 0.793 62.885 -108.130 0.072
deg+1.0 Ice+1.0 Temp
1.2 Dead+1.0 Wind 150 35.663 0.794 1.378 109.601 -61.325 0.082
deg+1.0 Ice+1.0 Temp
1.2 Dead+1.0 Wind 180 35.663 -0.004 1.594 126.851 2.460 0.071
deg+1.0 Ice+1.0 Temp
1.2 Dead+1.0 Wind 210 35.663 -0.802 1.383 110.015 66.133 0.041
deg+1.0 Ice+1.0 Temp -
1.2 Dead+1.0 Wind 240 35.663 -1.385 0.801 63.603 112.635 -0.000
deg+1.0 Ice+1.0 Temp
1.2 Dead+1.0 Wind 270 35.663 -1.597 0.004 0.052 129.504 -0.041
Job ob Page
78702.004.01 - BARROWS RD, OR (BU#879602) 11 of 15
Project Date
B+T Group 17:07:09 05/03/19
1717 S.Boulder,Suite 300
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle
FAX:(918)295-0265 Rakshak
Load Vertical Shear, Shear, Overturning Overturning Torque
Combination Moment,M, Moment,M,
K K K kip ft kip ft kip ft
deg+1.0 Ice+1.0 Temp
1.2 Dead+1.0 Wind 300 35.663 -1.380 -0.793 -63.611 112.221 -0.071
deg+1.0 Ice+1.0 Temp
1.2 Dead+1.0 Wind 330 35.663 -0.794 -1.378 -110.326 65.416 -0.082
deg+1.0 Ice+1.0 Temp
Dead+Wind 0 deg-Service 14.692 0.021 -3.431 -259.168 -1.710 -0.165
Dead+Wind 30 deg-Service 14.692 1.742 -2.982 -225.433 -131.864 -0.098
Dead+Wind 60 deg-Service 14.692 2.996 -1.734 -131.275 -226.609 -0.004
Dead+Wind 90 deg-Service 14.692 3.448 -0.021 -1.923 -260.559 0.090
Dead+Wind 120 deg-Service 14.692 2.975 1.697 127.963 -224.617 0.161
Dead+Wind 150 deg-Service 14.692 1.705 2.961 223.581 -128.412 0.188
Dead+Wind 180 deg-Service 14.692 -0.021 3.431 259.309 2.276 0.165
Dead+Wind 210 deg-Service 14.692 -1.742 2.982 225.574 132.431 0.097
Dead+Wind 240 deg-Service 14.692 -2.996 1.734 131.415 227.176 0.004
Dead+Wind 270 deg-Service 14.692 -3.448 0.021 2.063 261.126 -0.090
Dead+Wind 300 deg-Service 14.692 -2.975 -1.697 -127.823 225.183 -0.160
Dead+Wind 330 deg-Service 14.692 -1.705 -2 961 -223.441 128.978 -0.188
Solution Summary
Sum of Applied Forces Sum of Reactions
. Load PX PY PZ PX PY PZ %Error
Comb. K K K K K K
1 0.000 -14.692 0.000 0.000 14.692 0.000 0.000%
2 0.091 -17.631 -14.571 -0.091 17.631 14.571 0.000%
3 0.091 -13.223 -14.571 -0.091 13.223 14.571 0.000%
4 7.400 -17.631 -12.664 -7.400 17.631 12.664 0.000%
5 7.400 -13.223 -12.664 -7.400 13.223 12.664 0.000%
6 12.726 -17.631 -7.364 -12.726 17.631 7.364 0.000%
7 12.726 -13.223 -7.364 -12.726 13.223 7.364 0.000%
8 14.643 -17.631 -0.091 -14.643 17.631 0.091 0.000%
9 14.643 -13.223 -0.091 -14.643 13.223 0.091 0.000%
10 12.636 -17.631 7.207 -12.636 17.631 -7.207 0.000%
11 12.636 -13.223 7.207 -12.636 13.223 -7.207 0.000%
12 7.243 -17.631 12.574 -7.243 17.631 -12.574 0.000%
13 7.243 -13.223 12.574 -7.243 13.223 -12.574 0.000%
14 -0.091 -17.631 14.571 0.091 17.631 -14.571 0.000%
15 -0.091 -13.223 14.571 0.091 13.223 -14.571 0.000%
16 -7.400 -17.631 12.664 7.400 17.631 -12.664 0.000%
17 -7.400 -13.223 12.664 7.400 13.223 -12.664 0.000%
18 -12.726 -17.631 7.364 12.726 17.631 -7.364 0.000%
19 -12.726 -13.223 7.364 12.726 13.223 -7.364 0.000%
• _ 0.091 14.643 17.631 -0.091 0.000%.
21 -14.643 -13.223 0.091 14.643 13.223 -0.091 0.000%
22 -12.636 -17.631 -7.207 12.636 17.631 7.207 0.000%
23 -12.636 -13.223 -7.207 12.636 13.223 7.207 0.000%
24 -7.243 -17.631 -12.574 7.243 17.631 12.574 0.000%
25 -7.243 -13.223 -12.574 7.243 13.223 12.574 0.000%
26 0.000 -35.663 0.000 0.000 35.663 0.000 0.000%
27 0.004 -35.663 -1.594 -0.004 35.663 1.594 0.000%
•
28 0.802 -35.663 -1.383 -0.802 35.663 1.383 0.000%
29 1.385 -35.663 -0.801 -1.385 35.663 0.801 0.000%
30 1.597 -35.663 -0.004 -1.597 35.663 0.004 0.000%
31 1.380 -35.663 0.793 -1.380 35.663 -0.793 0.000%
32 0.794 -35.663 1.378 -0.794 35.663 -1.378 0.000%
33 -0.004 -35.663 1.594 0.004 35.663 -1.594 0.000%
34 -0.802 -35.663 1.383 0.802 35.663 -1.383 0.000%
35 -1.385 -35.663 0.801 1.385 35.663 -0.801 0.000%
Job Page
tnxTower 78702.004.01 - BARROWS RD, OR (BU#879602) 12 of 15
B+T Group Project Date
1717 S.Boulder,Suite 300 17:07:09 05/03/19
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle Rakshak
FAX:(918)295-0265
Sum of Applied Forces Sum of Reactions
Load PX PY PZ PX PY PZ %Error
Comb. K K K K K K
36 -1.597 -35.663 0.004 1.597 35.663 -0.004 0.000%
37 -1.380 -35.663 -0.793 1.380 35.663 0.793 0.000%
38 -0.794 -35.663 -1.378 0.794 35.663 1.378 0.000%
39 0.021 -14.692 -3.431 -0.021 14.692 3.431 0.000%
40 1.742 -14.692 -2.982 -1.742 14.692 2.982 0.000%
41 2.996 -14.692 -1.734 -2.996 14.692 1.734 0.000%
42 3.448 -14.692 -0.021 -3.448 14.692 0.021 0.000%
43 2.975 -14.692 1.697 -2.975 14.692 -1.697 0.000%
44 1.705 -14.692 2.961 -1.705 14.692 -2.961 0.000%
45 -0.021 -14.692 3.431 0.021 14.692 -3.431 0.000%
46 -1.742 -14.692 2.982 1.742 14.692 -2.982 0.000% I
47 -2.996 -14.692 1.734 2.996 14.692 -1.734 0.000%
48 -3.448 -14.692 0.021 3.448 14.692 -0.021 0.000%
49 -2.975 -14.692 -1.697 2.975 14.692 1.697 0.000%
50 -1.705 -14.692 -2.961 1.705 14.692 2.961 0.000%
Non-Linear Convergence Results
Load Converged? Number Displacement Force
Combination of Cycles Tolerance Tolerance
•
1 Yes 4 0.00000001 0.00000001
2 Yes 5 0.00000001 0.00009677
3 Yes 5 0.00000001 0.00004572
4 Yes 6 0.00000001 0.00010895
5 Yes 5 0.00000001 0.00090010
6 Yes 6 0.00000001 0.00011150
7 Yes 5 0.00000001 0.00092133
8 Yes 4 0.00000001 0.00085001
9 Yes 4 0.00000001 0.00046003
10 Yes 6 0.00000001 0.00011201
11 Yes 5 0.00000001 0.00092793
12 Yes 6 0.00000001 0.00010321
13 Yes 5 0.00000001 0.00085297
14 Yes 5 0.00000001 0.00017715
15 Yes 5 0.00000001 0.00008224
16 Yes 6 0.00000001 0.00011393
17 Yes 5 0.00000001 -- 0.00094194
18 Yes 6 0.00000001 0.00011158
19 Yes 5 0.00000001 0.00092159
20 Yes 5 0.00000001 0.00011608
21 Yes 5 0.00000001 0.00005381
22 Yes 6 0.00000001 0.00010404
23 Yes 5 0.00000001 0.00085931
24 Yes 6 0.00000001 0.00011268
25 Yes 5 0.00000001 0.00093361
26 Yes 4 0.00000001 0.00003899
27 Yes 5 0.00000001 0.00024451
28 Yes 5 0.00000001 0.00025977
29 Yes 5 0.00000001 0.00025892
30 Yes 5 0.00000001 0.00023887
31 Yes 5 0.00000001 0.00025729 -
32 Yes 5 0.00000001 0.00025735
33 Yes 5 0.00000001 0.00024401
34 Yes 5 0.00000001 0.00026848
35 Yes 5 0.00000001 0.00026955
36 Yes 5 0.00000001 0.00024994
Job Page
tnxTower 78702.004.01 - BARROWS RD, OR (BU#879602) 13 of 15
B+T Group Project Date
1717 S.Boulder,Suite 300 17:07:09 05/03/19
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle
FAX(918)295-0265 Rakshak
37 Yes 5 0.00000001 0.00026779
38 Yes 5 0.00000001 0.00026759
39 Yes 4 0.00000001 0.00016074
40 Yes 4 0.00000001 0.00061433
41 Yes 4 0.00000001 0.00065617
42 Yes 4 0.00000001 0.00009486
43 Yes 4 0.00000001 0.00071347
44 Yes 4 0.00000001 0.00055994
45 Yes 4 0.00000001 0.00018209
46 Yes 4 0.00000001 0.00070936
47 Yes 4 0.00000001 0.00066079
48 Yes 4 0.00000001 0.00011463
49 Yes 4 0.00000001 0.00056992
50 Yes 4 0.00000001 0.00073095
Maximum Tower Deflections - Service Wind
Section Elevation�..mma. e..m.._ Horz. Gov. Tilt Twist
No. Deflection Load
ft in Comb. °
L1 100-72.75 14.375 47 1.119 0.003
L2 76-36 8.901 47 1.023 0.002
L3 40-0 2.619 47 0.588 0.001
Critical Deflections and Radius of Curvature - Service Wind
Elevation Appurtenance Gov. Deflection Tilt Twist Radius of
Load Curvature
ft Comb. in ft
101.000 Top Hat 47 14.375 1.119 0.003 38629
99.000 APXVSPP18-C-A20 w/Mount Pipe 47 14.141 1.117 0.003 38629
96.000 Miscellaneous[NA 509-3] 47 13.440 1.109 0.003 38629
87.000 (2)TME-FXFB 47 11.355 1.081 0.003 14857
86.000 (2)TMBXX-6516-A2M w/Mount 47 11.127 1.078 0.003 13796
Pipe
Maximum Tower Deflections - Design Wind
Section Elevation _ Horz. Gov. Tilt Twist
No. Deflection Load
ft in Comb. °
Ll 100-72.75 61.399 18 4.787 0.014
L2 76-36 38.033 18 4.374 0.008
L3 40-0 11.191 18 2.515 0.003
Critical Deflections and Radius of Curvature - Design Wind
Job Page
tnxTower 78702.004.01 - BARROWS RD, OR (BU#879602) 14 of 15
B+T Group Project Date
1717 S.Boulder,Suite 300 17:07:09 05/03/19
Tulsa,OK 74119 Client Designed by
Phone:(918)587-4630 Crown Castle Rakshak
FAX:(918)295-0265
Elevation Appurtenance Gov. Deflection Tilt Twist Radius of
Load Curvature
ft Comb. in ° ft
101.000 Top Hat 18 61.399 4.787 0.014 9187
99.000 APXVSPP18-C-A20 w/Mount Pipe 18 60.401 4.776 0.014 9187
96.000 Miscellaneous[NA 509-3] 18 57.407 4.744 0.013 9187
87.000 (2)TME-FXFB 18 48.510 4.626 0.011 3532
86.000 (2)TMBXX-6516-A2M w/Mount 18 47.535 4.609 0.011 3280
Pipe
Compression Checks
Pole Design Data
Section Elevation Size L L„ Kl/r A P. 4)P, Ratio
No. P.
ft ft ft in' K K gyp,,
L1 100-72.75(1) TP26.088x22x0.188 27.250 0.000 0.0 15.124 -8.480 884.747 0.010
L2 72.75-36(2) TP31.227x25.225x0.219 40.000 0.000 0.0 21.113 -12.060 1235.090 0.010
L3 36-0(3) TP36.19x30.189x0.25 40.000 0.000 0.0 28.518 -17.614 1668.330 0.011
Pole Bending Design Data
Section Elevation Size M. 011. Ratio M,,, +M,, Ratio
No. M M,,
ft tap ft kip ft $M lap-ft kip ft 4,MY
L1 100-72.75(1) TP26.088x22x0.188 164.682 527.837 0.312 0.000 527.837 0.000
L2 72.75-36(2) TP31.227x25.225x0.219 573.558 873.300 0.657 0.000 873.300 0.000
L3 36-0(3) TP36.19x30.189x0.25 1121.100 1375.883 0.815 0.000 1375.883 0.000
Pole Shear Design Data
Section Elevation Size Actual 4iV Ratio Actual 4)T Ratio
No. V. V. T T
ft K K 4>V 1913-ft kip ft 4)T
L1 100-72.75(1) TP26.088x22x0.188 10.136 265.424 0.038 0.019 590.711 0.000
L2 72.75-36(2) TP31.227x25.225x0.219 12.536 370.528 0.034 0.019 986.708 0.000
L3 36-0(3) TP36.19x30.189x0.25 14.723 500.498 0.029 0.019 1575.292 0.000
Pole Interaction Design Data
Job Page
tnxTower 78702.004.01 - BARROWS RD, OR (BU#879602) 15 of 15
B+T Group Project Date
1717 S.Boulder,Suite 300 17:07:09 05/03/19
Tulsa,OK 74119 Client Designed by
- Phone:(918)587-4630 Crown Castle
FAX:(918)295-0265 Rakshak
Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria
No. P. M MY V T Stress Stress
ft 4P„ (I)M„,„ +M y 4V (PT Ratio Ratio
LI 100-72.75(1) 0.010 0.312 0.000 0.038 0.000 0.323 1.050 482 V
V '/
L2 72.75-36(2) 0.010 0.657 0.000 0.034 0.000 0.668 1.050 482 Y
V
L3 36-0(3) 0.011 0.815 0.000 0.029 0.000 0.826 1.050 482 V
V
Section Capacity Table
Section Elevation Component Size Critical P 0Pallo„, % Pass
No. ft Type Element K K Capacity Fail
L1 100-72.75 Pole TP26.088x22x0.188 1 -8.480 928.984 30.8 Pass
L2 72.75-36 Pole TP31.227x25.225x0.219 2 -12.060 1296.844 63.6 Pass
L3 36-0 Pole TP36.19x30.189x0.25 3 -17.614 1751.746 78.7 Pass
Summary
Pole(L3) 78.7 Pass
RATING= 78.7 Pass
Program Version 8.0.5.0
APPENDIX B
BASE LEVEL DRAWING
--_ —\\
/ \ CLIMBING PEGS
/ /��� `\ \
(OTHER CONSIDERED EQUIPMENT) /
(3) 1-1/4"TO 99 FT LEVEL , / \ \
/ \
l / 0 \\ \
I I 03 0, I I
(OTHER CONSIDERED EQUIPMENT) 1 02 1
E.
(1) 5/16" GROUND TO 75 FT LEVEL 1. \ \ / /
\ \ /
\ / /
(FINAL CONFIGURATION EQUIPMENT) \ i /
(1) 5/8"TO 86 FT LEVEL \ =_' /
(18) 7//a" TO E6 FT LEEi
VEL \ ./0
B „ SI \ ESS U \ IT: 879602
APPENDIX C
ADDITIONAL CALCULATIONS
•
Monopole Base Plate Connectionl�� CROWN
`�.J : CASTLE
Site Info
BU# 879602
Site Name BARROWS RD,OR
Order# 485007;Rev.0
Analysis Considerations
TIA-222 Revision H
Grout Considered: No
I,(in) 1.125
Applied Loads
Moment(kip-ft) 1121.10
Axial Force(kips) 17.61
Shear Force(kips) 14.72
*7IA-222-H Section 15.5 Applied
Connection Properties Analysis Results
Anchor Rod Data Anchor Rod Summary (units of kips,kip-in)
(8)2-1/4"0 bolts(A615-75 N;Fy=75 ksi,Fu=100 ksi)on 42"BC Pu_c=162.17 4Pn_c=243.75 Stress Rating
Anchor Spacing:6in Vu=1.84 4 Vn=73.13 63.4%
Mu=n/a 4Mn=n/a Pass
Base Plate Data
41"OD x 2.25"Plate(A572-55;Fy=55 ksi,Fu=70 ksi) Base Plate Summary
Max Stress(ksi): 31.31 (Flexural)
Stiffener Data Allowable Stress(ksi): 49.5
N/A Stress Rating: 60.2% Pass
Pole Data
36.19"x 0.25"18-sided pole(A607-65;Fy=65 ksi,Fu=80 ksi)
CClplate-version 3.6.0 Analysis Date:5/3/2019
Drilled Pier Foundation ( CROWN
BU#: 879602 CASTLE
Site Name: BARROWS RD,OR
Order Number: 485007;Rev.0
TIA-222 Revison: H
Tower Type: Monopole
Analysis Results Check Limitation
Applied Loads Soil Lateral Capacity Compression Uplift A..I TIA-222-H Section 15.5: 0
Comp. Uplift D,,,(,(ft from TOC) 5.33 - N/A MOM
Moment(kip-ft) 1121 Soil Safety Factor 3.44 -
Axial Force(kips) 18 Max Moment(kip-ft) 1183.43 -
Shear Force(kips) 15 Rating* 36.9% -
Soil Vertical Capacity Compression Uplift
Material Properties Skin Friction(kips) 241.75 -
Concrete Strength,f'c: 3 ksi End Bearing(kips) 318.09 -
Rebar Stren•th,F : 60 ksi Weight of Concrete(kips) 106.88 -
Total Capacity(kips) 559.83 -
Pier Design Data Axial(kips) 124.88 -
Depth 20.5 ft Rating* 21.2% -
Ext.Above Grade 0.5 ft Reinforced Concrete Capacity Compression Uplift
Pier Section 1 Critical Depth(ft from TOC) 5.17 -
From 0.5'above grade to 20.5'below grade Critical Moment(kip-ft) 1183.33 -
Pier Diameter 6 ft Critical Moment Capacity 3314.83 -
Rebar Quantity 16 Rating* 34.0% -
Rebar Size 11
Clear Cover to Ties 4 in Soil Interaction Rating* 36.9%
_ Tie Size 4 Structural Foundation Rating* 34.0%
*Rating per TIA-222-H Section 15.5
Soil Profile
Groundwater Death n/a ft #of La ers 4
Angle of Calculated Calculated Ultimate Skin Ult.Gross
Ultimate Skin
Top Bottom Thickness Y.on y,on„.,. Cohesion Ultimate Skin Ultimate Skin Friction Comp Bearing SPT Blow
LayerFriction Friction Uplift Soil Type
(ft) (ft) (ft) (pcf) (pcf) (ksf) Friction Comp Friction Uplift Override Capacity Count
(degrees) (ksf) (ksf) (ksf) Override(ksf) (ksf)
1 0 2 2 100 150 0 0 0.000 0.000 0.00 0.00 Cohesionless
2 2 8 6 100 150 0 30 0.000 0.000 0.60 0.60 Cohesionless
3 8 18 10 100 150 0 32 0.000 0.000 0.90 0.90 Cohesionless
4 18 20.5 2.5 100 150 0 32 0.000 0.000 1.80 1.80 15 Cohesionless
Version 2.1.1 , . . ' . .
Seismic Design Category Date: 5/3/2019
Site BU : 879602 CROWN
Site Name : BARROWS RD CASTLE
App: 485007 Rev. 0
Site Information
Site Latitude = 45.0 ° 25.0 34.6
Site Longitude = -122.0 ° 50.0 53.9
Site Class = D -Stiff Soil
Spectral Response Acceleration Short Periods, Ss= 0.956
Spectral Response Acceleration 1 s Period, Si = 0.424
Seismic Category Determination
Site Class Amplification, Fa= 1.12
Site Class Amplification, Fv= 1.58
1-S Period Response Acceleration Parameter, SDI= 0.45
Short Period response Acelleration Parameter,SDs = 0.71
Seismic Category Based on SDI.= D
Seismic Category Based on SDs= D
•
D
ASCE.
ASCE 7 Hazards Report
AMERICAN SOCIETY OF CML ENGINEERS
Address: Standard: ASCE/SEI 7-10 Elevation: 313.14 ft (NAVD 88)
No Address at This Risk Category: II Latitude: 45.426281 -
Location Soil Class: D Stiff Soil •
Longitude: -122.848292
.�.. V'"(.�14-x- �` �1 ‘'.......-...-,'S' � `�" - r
1 �� '','":1':;,.,` !,'..41i. 45P !
fi
�jf '�� 444 R000to I,
8
lir
f syY � /r II dIst:ora _,,,11
f f i^. rtland
..... IY ,Pr ,, J n !HIL
`� � P
\t L
�; q 50` // �/ I
f
-SIR !'I - - - _Along
''` r . - � fifes ` , f✓/ r Ji e n ill i.
6!;"........„...,..."-t.,...- 4.0., °
° �� _111110:10.4
.tc
n G� _ Lak,c�.. r
;. _,. -'-'—"--- 1.31*---''. -�.,,t "„r `�
po
1R,—_ iSAA ,yam' • V i.irG l tf�19Qe,'rV iJ 1.'r 4 - M TuLLlin
At ` j O"
ft t._._..fii �L. / "/ 1 ,
A
7
p -1,-.4'-''''''Ti......,'',,,,...
4i "rd i //.. ; i _4'4°h.k..,;.,.:
ril
,1 � � .o.,,,,,,— — 3 �� ?H:LLSCFO4'NLEE 'tl4 nta J op R(E7 Tfk4VNTA N
b.W
•: !` ��,���`',; wt4Laaacrre VALLEY 4
-_`. _.n M -MUM"
sv " - = •
N.
Wind
Results:
Wind Speed: 110 Vmph
10-year MRI 72 Vmph
25-year MRI 79 Vmph
50-year MRI 85 Vmph
100-year MRI 91 Vmph
Data Source: ASCE/SEI 7-10, Fig. 26.5-1A and Figs. CC-1—CC-4, incorporating errata of
March 12, 2014
Date Accessed: Fri May 03 2019
Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear
interpolation between contours. Wind speeds are interpolated in accordance with the 7-10 Standard. Wind speeds
correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability =
0.00143, MRI =700 years).
Site is not in a hurricane-prone region as defined in ASCE/SEI 7-10 Section 26.2.
Mountainous terrain, gorges, ocean promontories, and special wind regions should be examined for unusual wind
conditions.
https://asce7hazardtool.online/ Page 1 of 3 Fri May 03 2019
ASCE.
AMERICAN SOCIETY OF CML ENGINEERS
Seismic
• Site Soil Class: D-Stiff Soil
Results:
SS : 0.956 SDS : 0.712
S1 : 0.424 Sp, : 0.446
Fa : 1.118 TL : 16
F, : 1.576 PGA : 0.421
SMS : 1.069 PGA M : 0.454
SM, : 0.669 FPGA : 1.079
le : 1
Seismic Design Category D
1.2 MCER Response Spectrum 0.8 Design Response Spectrum
1.0 °110.7
ilic
* Os '
0.6 •
.5 is
0.6 a_a
0.4 , 0.3o
0.2
02 01 €
0 2 4 Sa(g)vs T(s) 10 12 14 16 18 0 2 4 Sa(g,}vs TPs) 10 12 14 16 18
Data Accessed: Fri May 03 2019
Date Source: USGS Seismic Design Maps based on ASCE/SEI 7-10, incorporating
Supplement 1 and errata of March 31, 2013, and ASCE/SEI 7-10 Table 1.5-2.
Additional data for site-specific ground motion procedures in accordance with
ASCE/SEI 7-10 Ch. 21 are available from USGS.
https://asce7hazardtool.online/ Page 2 of 3 Fri May 03 2019
ASCE
AMERICAN SOCIETY Of CML ENGINEERS
Ice
Results:
Ice Thickness: 1.00 in.
Concurrent Temperature: 25 F
Gust Speed: 30 mph
Data Source: Standard ASCE/SEI 7-10, Figs. 10-2 through 10-8
Date Accessed: Fri May 03 2019
Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys
and gorges may exceed the mapped values.
Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds,
for a 50-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain.
Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice
thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may
exceed the mapped values.
The ASCE 7 Hazard Tool is provided for your convenience,for informational purposes only,and is provided"as is"and without warranties of
any kind.The location data included herein has been obtained from information developed,produced,and maintained by third party providers;
or has been extrapolated from maps incorporated in the ASCE 7 standard.While ASCE has made every effort to use data obtained from
reliable sources or methodologies,ASCE does not make any representations or warranties as to the accuracy,completeness,reliability,
currency,or quality of any data provided herein.Any third-party links provided by this Tool should not be construed as an endorsement,
affiliation,relationship,or sponsorship of such third-party content by or from ASCE.
ASCE does not intend,nor should anyone interpret,the results provided by this Tool to replace the sound judgment of a competent
professional,having knowledge and experience in the appropriate field(s)of practice,nor to substitute for the standard of care required of such
professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard.
In using this Tool,you expressly assume all risks associated with your use.Under no circumstances shall ASCE or its officers,directors,
employees,members,affiliates,or agents be liable to you or any other person for any direct,indirect,special,incidental,or consequential
damages arising from or related to your use of,or reliance on,the Tool or any information obtained therein.To the fullest extent permitted by
law,you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data
provided by the ASCE 7 Hazard Tool.
https://asce7hazardtool.online/ Page 3 of 3 Fri May 03 2019
( CROWN BU: 879602 Structure: A
1 CASTLE WO: 1735475
Order: 485007 Rev: 0
•
Location
Decimal Degrees Deg Min Sec
Lat: 45.426278 ® 45 25 34.60
Long: -122.848306 0 122 50 53.90
Code and Site Parameters
Seismic Design Code: TIA-222-H*
Site Soil: D Dense Soil/Soft Rock
Risk Category: II
USGS Seismic Reference Ss: 0.9560 g
S1: 0.4240 g
TL: 16 s
Seismic Design Category Determination
Importance Factor,l : 1
Acceleration-based site coefficient,Fa: 1.1176
Velocity-based site coefficient,Fv: 1.5760
Design spectral response acceleration short period,SDs: 0.7123 g
Design spectral response acceleration 1 s period,S01: 0.4455 g
Seismic Design Category Based on SDs: D
Seismic Design Category Based on SD1: D
Seismic Design Category Based on Si: N/A
Controlling Seismic Design Category: D
*Using ASCE 7-10 Seismic Parameters
CCISeismic 3.2.3 Page 1 Analysis Date: 5/3/2019
CROWN BU:
WO: 879602
1735475 Structure: A
,„• CASTLE Order: 485007 Rev: 0
Tower Details
Tower Type: Tapered Monopole
Height,h: 100 ft
Effective Seismic Weight,W: 14.69 kips
Amplification Factor,A5: 1.0 2.7.8.1
Seismic Base Shear
Response Modification Factor,R: 1.5
Discrete Appurtenance Weight in Top 1/3 of Structure,Wu: 6.42563 kips
W1: 8,266546179 kips
E: 29000.0 ksi
g: 386.088 in/s2
a
Average Moment of Inertia,laug: 2337.787836 in
Fa: 0.370698976 hz
Approximate Fundamental Period Monopole,Ta: 2.6976 s 2.7.7.1.3.3
Seismic Response Coefficient,C, 0.4749 2.7.7.1.1
Seismic Response Coefficient Max 1,Cama. 0.1101 2.7.7.1.1
Seismic Response Coefficient Max 2,Csmax N/A 2.7.7.1.1
Seismic Response Coefficient Min 1,Csmin 0.0313 2.7.7.1.1
Seismic Response Coefficient Min 2,Csmin N/A 2.7.7.1.1
•
Controlling Seismic Response Coefficient,Cs, 0.1101
Seismic Base Shear,V 1.618 kips 2.7.7.1.1
Vertical Distribution Factors
Period Related Exponent,k: 2.000 2.7.7.1.2
Sum of w;hik 78647.96 2.7.7.1.2
CCISeismic 3.2.3 Page 2 Analysis Date: 5/3/2019
Tower Section Loads
Section Section
Length Top Height Mid Height,h„ w,h,k C,,, F, F,,,
Number Weight,w, h
®® 100.00 IMEMIIIIMMOMEMEM 0.0388 0.0627 0.0468
- 1-2 10.00 r k.
87.75 0.4789 3687.70 0.0469 �0.0758 :EM
• ® 10.00 ® 0.5093 sa:iti# ,k
® 10.00 MC= 71.00 0.6085 3067.49 0.0390 0.0631 MEM
• ® 10.00 11.33=1111=110.6440 1116r 0.0305 0.0493 0.0917
• =IIMMTEMIIMEIMMIEECM0.6794 ME= 0.0225 Mar= 0.0968
11110111 10.00 46.00 41.00 MEM 1201.66 MB= 0.0247 MEM
3-1 10.00 40.00 35.00 MEM 1015.06 0.0129 0.0209 0.1180
® 10.00 30.00. k sMIZECIII 0.0069 IlliniallEMMIE
3-3 10.00 20.00 MN= 0.9096 204.67 0.0026 0.0042 0.1296
IllinM® 10.00111[0.11.1=1.11111M111�4 0.0003 0.0005
MIME
Sum 3'n,'.. :.�1"£I..:,t;
•
CCISeismic 3.2.3 Page 3 Analysis Date: 5/3/2019
Discrete Loads
Name 11„ wx w„hxk C.. IF,,), Fx„
miscl Top Hat 101.00 00810 826.28 0.0105 0.0170 0.0115
rfs celwave APXV5PP18-C-420 w/Mount Pipe 99.00 0.0876 858.47 0.0109 0.0177 0.0125
rfs celwave APXVSPPS8-C-A20 4 Mount Pipe 99.00 0.0876 858.47 0.0109 0.0177 0.0125
rfs celwave APXVERR18-C w/Mount Pipe 99.00 0.0760 744.88 0.0095 0.0153 0.0108
kmw communications ET-X-WM-18-65-8P 4 Mount Pipe 99.00 0.0586 574.73 0.0073 0.0118 0.0084
kmw communications ET-X-WM-18-65-8P w/Mount Pipe 99.00 0.0586 574.73 0.0073 0.0118 0.0084 •
kmw communications ET-X-WM-18-65-8P 4 Mount Pipe 99.00 0.0586 574.73 0.0073 0.0118 0.0084
samsung telecommunications RRH-P4 99.00 0.0600 588.06 0.0075 0.0121 0.0085
samsung telecommunications RRH-P4 99.00 0.0600 588.06 , 0.0075 0.0121 0.0085
samsung telecommunications RRH-P4 99.00 0.0600 588.06 0.0075 0,0121 0.0085
samsung telecommunications RRH-C2A W/EXT FILTER 99.00 0.0550 539.06 0.0069 0.0111 0.0078
samsung telecommunications RRH-C2A W/EXT FILTER 99.00 0.0550 539.06 0.0069 0.0111 0.0078
samsung telecommunications RRH-C2A W/EXT FILTER 99.00 0.0550 539.06 0.0069 0.0111 0.0078
samsung telecommunications POWER JUNCTION CYLINDER 99.00 0.0030 29,40 0.0004 0.0006 0.0004
samsung telecommunications POWER JUNCTION CYLINDER 99.00 0.0030 29.40 0.0004 0.0006 0.0004
samsung telecommunications POWER JUNCTION CYLINDER 99.00 0.0030 29.40 0.0004 0.0006 0.0004
samsung telecommunications 2.5GHz RRH-V3 99.00 00600 588.06 0.0075 0.0121 0.0085
samsung telecommunications 2.5GHz RRH-V3 99.00 0.0600 588.06 0.0075 0.0121 0.0085
samsung telecommunications 2.5GHz RRH-V3 99.00 0.0600 588.06 0.0075 0.0121 0.0085
(2)tower mounts 6'x 2"Mount Pipe 99.00 0.0440 431.24 0.0055 0.0089 0.0063
(2)tower mounts 6'x 2"Mount Pipe 99.00 0.0440 431.24 0.0055 0.0089 0.0063
(2)tower mounts 6'x 2"Mount Pipe 99.00 0.0440 431.24 0.0055 0.0089 0.0063
tower mounts Miscellaneous[NA 509-3] 96.00 0.2750 2534.40 0.0322 0.0521 0.0392
tower mounts Miscellaneous[NA 510-1] 99.00 0.2557 2506.12 0.0319 0.0515 0.0364
tower mounts Platform Mount[LP 1201-1] 99.00 2.1000 20582.10 0.2617 0,4233 0.2992
(2)nokia TME-FXFB 87.00 0.1100 832.59 0.0106 0.0171 0.0157
tower mounts 6'x 2"Mount Pipe 87.00 0.0220 166.52 0.0021 0.0034 0,0031
tower mounts 6'x 2"Mount Pipe 87.00 0.0220 166.52 0.0021 0.0034 0.0031
tower mounts Side Arm Mount[SO 104-3] 87.00 0.2870 2172.30 0.0276 0.0447 0.0409
(2)andrew TMBXX-6516-A2M pal Mount Pipe 86.00 0.1080 798.77 0.0102 0.0164 0.0154
(2)andrew TMBXX-6516-A2M 4 Mount Pipe 8600 0.1080 798,77 0.0102 0.0164 0.0154
(2)andrew TMBXX-6516-A2M 4 Mount Pipe 86.00 0.1080 798.77 0.0102 0.0164 0.0154
commscope FFHH-65C-R3 w/Mount Pipe 86.00 0.1605 1187.13 0.0151 0.0244 0,0229
commscope FEHH-65C-R3 wMount Pipe 86.00 0.1605 1187.13 0.0151 0.0244 0.0229
commscope FEHH-65C-R3 w/Mount Pipe 86.00 0.1605 1187.13 0.0151 0.0244 0.0229
commscope HCS 2.0 Part 1 86.00 0.0240 177.50 0.0023 0.0037 0.0034
nokia AHFIG 86.00 0.0790 584.28 0.0074 0.0120 0.0113
nokia AHFIG 86.00 0.0790 584.28 0.0074 0.0120 0.0113
nokia AHFIG 86.00 0.0790 584.28 0.0074 0.0120 0.0113
nokia AHLOA 86.00 0.0840 621.26 0.0079 0.0128 0.0120
nokia AHLOA 86.00 0.0840 621.26 , 0.0079 0.0128 0.0120
nokia AH LOA 86.00 0.0840 621.26 0.0079 0.0128 0.0120
tower mounts 5'x 2"Pipe Mount 86.00 0.0290 214.48 0.0027 0.0044 0.0041
tower mounts 5'x 2"Pipe Mount 86.00 0.0290 214.48 0.0027 0.0044 0.0041 •
tower mounts 5'x 2"Pipe Mount 86.00 0.0290 214.48 0.0027 0.0044 0.0041
tower mounts T-Arm Mount[TA 602-31 86.00 0.7743 5726.72 0.0728 0.1178 0.1103
Sum 6.4256 56622,32
•
CCISeismic 3.2.3 Page 4 Analysis Date: 5/3/2019
Linear Loath
Name Start Height End Height h, w„ w,h,` C„, F,, F,,,
(3)andrew LDF6-504(1-1/4)From 0 to 99 90,00 99.00 94.50 0.0162 144.67 0.0018 0.0030 0.0023
(3)andrew LDF6-50A(1-1/4)From 0 to 99 80.00 90.00 85.00 0.0180 130.05 0.0017 0.0027 0.0026
(3)andrew LDF6-50.4(1-1/4)From 0 to 99 70.00 80.00 75.00 0.0180 101.25 0.0013 0.0021 0.0026
(3)andrew LDF6-50A(1-1/4)From 0 to 99 60.00 70.00 65.00 0.0180 76.05 0.0010 0.0016 0.0026
(3)andrew LDF6-50A(1-1/4)From 0 to 99 50.00 60.00 55.00 0.0180 54.45 0.0007 0.0011 0.0026
(3)andrew LDF6-50A(1-1/4)From 0 to 99 40.00 50.00 45.00 0.0180 36.45 0.0005 0.0007 0.0026
•
(3)andrew LDF6-50A(1-1/4)From 0 to 99 30.00 40.00 35.00 0.0180 22.05 0.0003 0.0005 0.0026
(3)andrew LDF6-50411-1/4)From 0 to 99 20.00 30.00 25.00 0.0180 11.25 0.0001 0.0002 0.0026
(3)andrew LDF6-50A(1-1/4)From 0 to 99 10.00 20.00 15.00 0.0180 4.05 0.0001 0.0001 0.0026
(3)andrew LDF6-50.4(1-1/4)From 0 to 99 0.00 10.00 5.00 0.0180 0.45 0.0000 0.0000 0.0026
(18)andrew LDF5-50A(7/8)From 0 to 86 80.00 86.00 83.00 0.0356 245.52 0.0031 0.0050 0.0051
(18)andrew LDF5-50A(7/8)From 0 to 86 70,00 80.00 75.00 0.0594 334.13 0.0042 0.0069 0.0085
(18)andrew LDF5-50A(7/8)From 0 to 86 60.00 70.00 65.00 0,0594 250.97 0.0032 0,0052 0.0085
(18)andrew LDF5-50A(7/8)From 0 to 86 50.00 60.00 55.00 0.0594 179.69 0.0023 0.0037 0.0085
(18)andrew LDF5-50A)7/8)From 0 to 86 40.00 50.00 45.00 0.0594 120,29 0.0015 0.0025 0.0085
(18)andrew LDF5-50A(7/8)From 0 to 86 30.00 40.00 35.00 0.0594 72.77 0.0009 0.0015 0.0085
(18)andrew LDF5-50A(7/8)From 0 to 86 20.00 30.00 25.00 0.0594 37.13 0.0005 0.0008 0.0085
(18)andrew LDF5-504(7/8)From 0 to 86 10.00 20.00 15.00 0.0594 13.37 0.0002 0.0003 0.0085
(18)andrew LDF5-50A(7/8)From 0 to 84 0.00 10.00 5.00 0.0594 1.49 0.0000 0.0000 0.0085
nokia HCS 2.0 Part 2(5/8)From 0 to 86 80.00 86.00 83.00 0.0020 14.05 0.0002 0.0003 0.0003
nokia HCS 2.0 Part 2(5/8)From 0 to 86 70.00 80,00 75.00 0.0034 19.13 0.0002 0.0004 0.0005
nokia HCS 2.0 Part 2(5/8)From 0 to 86 60.00 70.00 65.00 0.0034 14.37 0.0002 0.0003 0,0005
nokia HCS 2.0 Part 2(5/8)From 0 to 86 50.00 60.00 55.00 0.0034 10.29 0.0001 0.0002 0.0005
nokia HCS 2.0 Part 2(5/8)From 0 to 86 40.00 50.00 45.00 0.0034 6.89 0.0001 0.0001 0.0005
nokia HCS 2.0 Part 2(5/8)From 0 to 86 30.00 40.00 35.00 0.0034 4.17 0.0001 0.0001 0,0005
nokia HCS 2.0 Part 2(5/8)From 0 to 86 20.00 30.00 25.00 0.0034 2.13 0.0000 0.0000 0.0005
nokia HCS 2.0 Part 2(5/8)From 0 to 86 10.00 20.00 15.00 0.0034 0.77 0.0000 0.0000 0.0005
nokia HCS 2.0 Part 2(5/8)From 0 to 86 0.00 10,00 5.00 0,0034 0.09 0.0000 0.0000 0.0005
andrew ATC13-801-001(5/161 From 0 to 75 70.00 75.00 72.50 0.0004 1.97 0.0000 0.0000 0.0001
andrew ATC8-801-001(5/16")From 0 to 75 60.00 70.00 65.00 0.0008 3.17 0.0000 0.0001 0.0001
andrew ATC8-801-001(5/16")From 0 to 75 50.00 60,00 55.00 0.0008 2.27 0.0000 0.0000 0.0001
andrew ATC8-801-001(5/16")From 0 to 75 40.00 50.00 45.00 0.0008 1.52 0.0000 0.0000 0.0001
andrew ATC8-801-001(5/16")From 0 to 75 30,00 40.00 35.00. 0.0008 0,92 0,0000 0.0000 0.0001
andrew ATCB-B01-001(5/16")From 0 to 75 20.00 30.00 _ 25.00 0.0008 0.47 0.0000 0.0000 0.0001
andrew ATCB-801-001(5/161 From 0 to 75 10.00 20.00 15,00 0.0008 0.17 0.0000 0.0000 0.0001
andrew ATC5-801-001(5/16")From 0 to 75 0.00 10,00 5,00 0.0008 0.02 0.0000 0.0000 0.0001
mind Safety Line 3/8 From 0 to 100 90.00 100.00 95.00 0.0022 19.86 0.0003 0.0004 0,0003
miscl Safety Line 3/8 From 0 to 100 80.00 90.00 85.00 0.0022 15,90 0.0002 0.0003 0.0003
mind Safety Line 3/8 From 0 to 100 70.00 80.00 75.00 0.0022 12.38 0.0002 0.0003 0.0003
miscl Safety Line 3/8 From 0 to 100 60.00 70.00 65.00 0.0022 9.30 0.0001 0.0002 0.0003
misci Safety Line 3/8 From 0 to 100 50.00 60.00 55,00 0.0022 6.66 0.0001 0.0001 0.0003
mind Safety Line 3/8 From 0 to 100 40.00 50.00 45.00 0.0022 4.46 0.0001 0.0001 0.0003
miscl Safety Line 3/8 From 0 to 100 30.00 40.00 35,00 0.0022 2.70 0.0000 0.0001 0.0003
miscl Safety Line 3/8 From 0 to 100 20.00 30.00 25.00 0.0022 1.38 0,0010 0.0000 0.0003
mind Safety Line 3/8 From 0 to 100 10.00 20.00 15.00 0.0022 0.50 0.0000 0.0000 0.0003
miscl Safety Line 3/8 From 0 to 100 0.00 10.00 5.00 0.0022 0.06 0.0000 0.0000 0.0003
Sum 0.7459 1991.55
•
CCISeismic 3.2.3 Page 5 Analysis Date: 5/3/2019
100.05 ---i
MATERIAL STRENGTH
GRADE Fy Fu 1 GRADE Fy Fu
A607-65 65 ksi 80 ksi 1
TOWER DESIGN NOTES
1. Tower is located in Washington County,Oregon.
2. Tower designed for Exposure C to the TIA-222-H Standard.
N o 8 3. Tower designed for a 120 mph basic wind in accordance with the TIA-222-H Standard. •
N N N 4. Tower is also designed for a 30 mph basic wind with 2.00 in ice.Ice is considered to increase
in thickness with height. •
5. Deflections are based upon a 60 mph wind.
6. Tower Risk Category II.
7. Topographic Category 1 with Crest Height of 0.000 ft
8. TIA-222-H Annex S
9. CCISeismic Note:Seismic loads generated by CCISeismic 3.2.3
/ 10. CCISeismic Note:Seismic calculations are in accordance with TIA-222-H
11. TOWER RATING:78.7%
72.80
0 0
N
? N N
N N N
C N N1 ,'2
`Ii 0
/ 36.0 e ALL REACTIONS
ARE FACTORED
AXIAL
20 K
54
SHEAR MOMENT
2 K ( J 150 kip-ft
TORQUE 0 kip-ft
SEISMIC
0
0 AXIAL
0.
v . o
36 K
SHEAR > MOMENT
2 K 130 kip-ft
TORQUE 0 kip-ft
30 mph WIND-2.000 in ICE
. AXIAL
18K
SHEAR MOMENT
15 K 1121 kip-ft
0.0 ft
in
TORQUE 1 kip-ft
REACTIONS-120 mph WIND
_ - Y
•
aF E u xo 0 a o
m - ( - mP .-
.-