Report (49) Ott 5153 - • 1 RECEIVED JUN 10 2019 r:ITy OF TIGARD ClifeVMe BUI1.nl .tG DIVISION Lkjudi [ System Power Requirements GFPS-9 Power Supply Protected Premises: Tempelton Elementary School Date: 5/30/2019 Address: 9500 SW Murdock St City: Tigard State: OR Zip: 97224 Prepared By: Scott Sullivan Advanced Alarm Systems Inc Phone: 503-550-0999 Address: 12017 NE Sumner St Email: City: Portland State: OR Zip: 97220 Primary Standby Load I 0.08 I Amps Current load on the primary power supply during non-alarm conditions. Primary Alarm Load 1.66 Amps Current load on the primary power supply during alarm conditions. Secondary Load Requirements 2.33 Amp Hours Total Secondary Load from the calculation table below. Current Draw Time(hours) Total (AH) Seconday Standby Load Required Standby Time 0.075 A 24 hours 1.80 Secondary Alarm Load Required Alarm Time (hours) 1.657 A x 0.084 hours 0.14 Total Secondary Load 1.94 Derating factor x 1.2 Secondary Load Requirements 2.33 AH Battery Selection I 7 I Amp Hours Select batteries from the list below. 7.0 AH BAT-1270 Battery(12 volt) {: Two r Four(two 12VDC sets in parallel) Page 2 of 3 tGarri0 calewe .., GFPS-9 Total Current Standb 0.075 A Alarm 1.657 A Cl -Standby Current C2-Alarm Current Device Qty Draw Standby Qty Draw Alarm 1.Power Supply GFPS-9 Distributed Power Module 1 x 0.07500 0.07500 1 x 0.20500 0.20500 2.NAC#1 NAC 1 1 x 0.00000 0.00000 1 x 0.84700 0.84700 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC#1 Totals(Max 3.0 Amps): 0.00000 0.84700 3.NAC#2 NAC 2 1 x 0.00000 0.00000 1 x 0.60500 0.60500 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC#2 Totals(Max 3.0 Amps): 0.00000 0.60500 4.NAC#3 NAC 3 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC#3 Totals(Max 3.0 Amps): 0.00000 0.00000 5.NAC#4 NAC 4 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC#4 Totals(Max 3.0 Amps): 0.00000 0.00000 6.Auxiliary Devices Auxiliary Device 1 0 x 0.00000 0 x 0.00000 Auxiliary Device 2 0 x 0.00000 0 x 0.00000 Auxiliary Device 3 0 x 0.00000 0 x 0.00000 Auxiliary Device 4 0 x 0.00000 0 x 0.00000 Auxiliary Device 5 0 x 0.00000 0 x 0.00000 Total Standby Load: 0.075 Total Alarm Load: 1.657 Battery Distribution Chart Shows amp-hour distribution of your selections. ■Spare Battery Capacity Secondary Alarm Load 2% a Secondary Standby Load Secondary Alarm Load Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (7AH) are within the charger range of this power supply(7-26AH). Spare Battery Capacity 4.67 Battery Selection(AH)-Secondary Load Requirements(AH) Secondary Standby Load 2.16 Secondary Standby Load(AH)*Derating Factor Secondary Alarm Load 0.17 Secondary Alarm Load(AH)*Deratinq Factor Page 3 of 3 This calculator provided voltage drop calculations in three formats(Point to Point, End of Line, and Load Centering). Make sure that you know what method is accepted by,and the results do not exceed the limits set by the respective jurisdiction Point to Point Method End of Line Method Load Centering Method Project Name Tempelton Elementary Portables CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS Date 5/30/20191 Circuit Number 1 Totals Voltage Totals Voltage Totals Voltage Area Covered Portables 10,11,12 Current Distance Drop Current Distance Drop Current I Distance Drop Nominal System Voltage 20.4 0.847 255 0.89 0.847 255 1.326 0.847 1 255 0.663 Minimum Device Voltage 16 End of Line Voltage 19.51 End of Line Voltage 19.07 End of Line Voltage 19.74 Total Circuit Current 0.847 Wire Ohm's Percent Drop 4.35% Percent Drop 6.50% Percent Drop 3.25% Gauge Per 1000 End of Line and Load Centering Methods use only the wire guage for the first device to source Standard Wire Resistance in Ohms per 1000 feet. Wire Gauge for balance of circuit 14 Distance from source to 1st devicd 70 I 14 l 3.07 3.07 18=7.77 16=4.89 14=3.07 12=1.98 10=1.24 Enter current in amps. Distance 18-14 Awg=Solid Conductors 12-10 Awg=Stranded Conductors .150= 150 ma from voltage Device Manufacturer System Sensor Device Device previous At Drop from Percent Device Manufacturer System Sensor Current Number Current device Device Source Drop Current @Rated Device 1 0.121 70 20.04 0.364 1.78% Horn Strobe @Rated Strobe Only Mod # Candela Voltage Device 2 0.121 30 19.90 '0.498 2.44% Model# Candela Voltage Device 3 0.121 45 19.74 0.665 3.26% P2WL Wall 15 0.054 SWL Wall 15 0.043 Device 4 0.121 30 19.65 0.754 3.70% 30 0.074 SWL Wall 30 0.063 P2WL Wall 75 0.121 SWL Wall 75 0.107 Device 5 0.121 40 19.56 0.843 4.13% P2WL Wall Device 6 0.121 20 19.53 0.873 4.28% P2WL Wall 95 0.142 SWL Wall 95 0.121 Device 7 0.121 20 19.51 0.888 4.35% P2WL Wall 110 0.162 SWL Wall 110 0.148 END 19.51 0.888 4.35% P2WL Wall 135 0.196 SWL Wall 135 0.172 85 0.222 END 19.51 0.888 4.35% P2WL Wall 185 0.245 SWL Wall 1 15 0.0412 END 19.51 0.888 4.35% PC2WL Ceiling 15 0.071 SCWL Ceiling END 19.51 0.888 4.35% PC2WL Ceiling 30 0.090 SCWL Ceiling 30 0.063 END 19.51 0.888 4.35% PC2WL Ceiling 75 0.143 SCWL Ceiling 75 0.111 END 19.51 0.888 4.35% PC2WL Ceiling 95 0.165 SCWL Ceiling 95 0.134 END 19.51 0.888 4.35% PC2WL Ceiling 110 0.187 SCWL Ceiling 110 0.158 END 19.51 0.888 4.35% PC2WL Ceiling 135 0.217 SCWL Ceiling 138 0.189 END 19.51 0.888 4.35% PC2WL Ceiling 185 0.254 SCWL Ceiling 185 0.226 END 19.51 0.888 4.35% END 19.51 0.888 4.35% P2WH-LF 135 0.352 END 19.51 0.888 4.35% P2WH-LF 185 0.344 END 19.51 0.888 4.35% HW-LF N/A 0.138 Totals 0.847 255 End of Line Voltage 19.51 This calculator provided voltage drop calculations in three formats(Point to Point, End of Line, and Load Centering). Make sure that you know what method is accepted by,and the results do not exceed the limits set by the respective jurisdiction Point to Point End of Load Centering Method thod Project Name Tempelton Elementary Portables CIRCUIT IS WITH NeLIM TS CIRCUIT ISLine WITHINthod LIMITS CIRCUIT IS WITHIN LIMITS Date 7/11/2018 Circuit Number 2 Totals Voltage Totals Voltage Totals Voltage Area Covered Portables 13,14 Current Distance Drop Current Distance Drop Current Distance Drop Nominal System Voltage 20.4 0.605 345 1.12 0.605 345 1.282 0.605 345 0.641 Minimum Device Voltage 16 End of Line Voltage 19.28 End of Line Voltage 19.12 End of Line Voltage 19.76 Total Circuit Current 0.605 Wire Ohm's Percent Drop 5.50% Percent Drop6.28% Percent Drop 3.14% Gauge Per 1000 End of Line and Load Centering Methods use only the wire guage for the first device to source Distance from source to 1st device 250 I 14 I 3.07 Standard Wire Resistance in Ohms per 1000 feet. Wire Gauge for balance of circuit 14 3.07 18=7.77 16=4.89 14=3.07 12=1.98 10=1.24 Enter current in amps. Distance 18-14 Awg =Solid Conductors 12-10 Awg=Stranded Conductors .150= 150 ma from Voltage Device Device previous At Drop from Percent Device Manufacturer [System Sensor _ Number Current device Device source Drop Current Device Manufacturer System Sensor Device 1 0.121 250 19.47 0.929 4.55% Horn Strobe Current Device 2 0.121 35 19.37 1.033 5.06% Model# Candela Voltage Strobe Only @Rated Device 3 0.121 20 19.32 1.077 5.28% P2WL Wall Model# Candela Volta 15 0.054 SWL Wall 15 0.043e Device 4 0.121 20 19.29 1.107 5.43% P2WL Wall 30 0.074 SWL Wall Device 5 0.121 20 19.28 1.122 5.50% P2WL Wall 75 0.121 SWL Wall 75 0.1107 END 19.28 1.122 5.50% P2WL Wall 95 0.142 SWL Wall 95 0.121 END 19.28 1.122 5.50% P2WL Wall 110 0.162 SWL Wall 110 0.148 END 19.28 1.122 5.50% P2WL Wall 135 0.196 SWL Wall 135 0.172 END 19.28 1.122 5.50% P2WL Wall 185 0.245 SWL Wall 185 0.222 END 19.28 1.122 5.50% PC2WL Ceiling 15 0.071 SCWL Ceiling 15 0.041 END 19.28 1.122 5.50% PC2WL Ceiling 30 0.090 SCWL Ceiling 30 0.063 END 19.28 1.122 5.50% PC2WL Ceiling 75 0.143 SCWL Ceiling 75 0.111 END 19.28 1.122 5.50% PC2WL Ceiling 95 0.165 SCWL Ceiling 95 0.134 END 19.28 1.122 5.50% PC2WL Ceiling 110 0.187 SCWL Ceiling 110 0.158 END 19.28 1.122 5.50% PC2WL Ceiling 135 0.217 SCWL Ceiling 138 0.189 END 19.28 1.122 5.50% PC2WL Ceiling 185 0.254 SCWL Ceiling 185 0.226 END 19.28 1.122 5.50% END 19.28 1.122 5.50% P2WH-LF 135 0.352 END 19.28 1.122 5.50% P2WH-LF 185 0.344 END 19.28 1.122 5.50% HW-LF N/A 0.138 Totals 0.605 345 End of Line Voltage 19.28 Honeywell I Addressable Devices a Velociti° Series 3 Detectors Photoelectric Detectors Description The Gamewell-FCI,Velociti®Series 3 intelligent photoelectric detectors with integral communication provide point location for alarm communication and selective maintenance.Designed in a modern bright white color,the Velociti Series 3 is aesthetically pleasing for today's contemporary buildings. The Velociti Series 3 smoke detectors are intelligent addressable detectors with point ID capability that enable each detector address to be set with rotary address switches providing exact device locations.The photoelectric detector continually monitors the detected temperature and reports it to the fire alarm control panel.Thern 11, 11, design and expanded color options support a variety of contemporary aesthetic demands.In addition,each detector is constructed for exceptional installation and maintenance efficiency. The Gamewell-FCI,ASD-PL3 photoelectric detector's re-designed optical sensing Photoelectric Detector chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards.The sensitivity of Velociti series detectors can be programmed using the control panel software to suit the environment.The ASD-PL3R photoelectric detector is also remote test capable that may be used with a DNR(DNRW)duct smoke detector housing.The ASD-PTL3 multi- sensor detector offers either photoelectric detection or thermal detection through dual electronic thermistors at 135°F fixed temperature thermal sensing. For legacy installations,service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility.Service models are designated by the-IV part number after the detector model. Note:Although the E3 Series®and S3 Series panels support both the Velociti®ander CLIP''protocols,the GWF-7075 panel does not support the CLIP protocol.To obtain a complete list of panels that are listed to Velociti Series 3 detectors,refer to the Compatibility Addendum for Gamewell-FLI Manuals,P/N:9000-0427 L8. FEATURES & BENEFITS • Complies with UL° • Contains a built-in • Provides rotary address • Includes dual LEDs for • Offers expanded color Standard 268 7th functional test switch switches(01-159) 360°visibility options Edition activated by external • Supplies optional relay, magnet isolator,or sounder • Designed with a new profile to offer modern • Supports a low standby bases(standard or low and improved current frequency) aesthetics • Ordering Information Ordering Information NOTE:'-IV'suffix indicates Ivory color model. Accessories NOTE:"-BL"suffix indicates Black color model. NOTE:"WH"suffix indicates Bright White color model. SM6600:Surface Mounting Kit(flanged) TR300:Accessory Flange Ring for B300 6"Base,bright ASD-PL3:Photoelectric smoke detector,bright white, , Velociti white TR300-IV:Accessory Flange Ring for B300 6"Base,ivory ASD-PL3R:Photoelectric smoke detector,remote test capable,for use with DNR(W)duct smoke detectors,bright RA100Z: Remote LED annunciator,3-32 VDC white,Velociti The annunciator mounts to a U.S.single-gang electrical ASD-PTL3:Photoelectric smoke detector with thermal box.For use with 8501 and B300-6. sensing,bright white,Velociti CK300: Bright White detector kit(Pack of 10) ASD-PL3-IV:Photoelectric smoke detector,ivory,Velociti/ CK300-IR: White,detector color kit for use with MCS-COF CLIP Series Detectors.(Pack of 10) ASD-PL3R-IV:Photoelectric smoke detector,remote test CK300-IV: Ivory,detector color kit.(Pack of 10) capable,for use with DNR(W)duct smoke detectors,ivory, CK300-IR-IV: Ivory,detector color kit for use with Velociti/CLIP MCSCOF Series detectors.(Pack of 10) ASD-PTL3-IV:Photoelectric smoke detector with thermal CK300-BL: Black detector kit.(Pack of 10) sensing,ivory,Velociti/CLIP CK300-IR-BI: Black,detector color kit for use with Intelligent Bases MCSCOF Series detectors.(Pack of 10) For details on intelligent bases,refer to Data Sheet M02-04-01: Detector test magnet. P/N:9021-60540. M02-09-00: Test magnet with telescoping handle. Note:"IV"suffix indicates Flashscan and CLIP devices. XR2B: Detector removal tool.Allows the installation and/ "WH"suffix indicates bright white or removal of the detector heads from the bases in high 8501-WHITE: 4"Flangeless mounting base,bright white ceiling applications. XP-4: Extension pole for XR2B.Shipped with three,5-foot 6501-WHITE-BP:4"Flangeless mounting base bulk pack, bright white (1.524,m)sections. B501-IV: 4"Flangeless mounting base,ivory B300-6: 6"Flanged mounting base,bright white B300-6-IV:6"Flanged mounting base,ivory 8300-6-BP:6"Flanged mounting base bulk(Pack of 10) B200SR-WH:Standard sounder base,bright white B200SR-IV:Standard sounder base,ivory B200S-WH:Intelligent addressable sounder base,bright white B200S-IV:Intelligent addressable sounder base,ivory B200SR-LF-WH:Standard low frequency sounder base, bright white B200SR-LF-IV:Standard low frequency sounder base, ivory 6200S-LF-WH:Intelligent addressable low frequency sounder base,bright white B200S-LF-IV:Intelligent addressable low frequency sounder base,ivory B224RB-WH:Relay base,bright white B224RB-IV: Relay base,ivory B224BI-WH:Isolator base,bright white 622461-IV: Isolator base,ivory DNR: Intelligent duct detector housing,non-relay DNRW: Intelligent duct detector housing,non-relay, watertight 2 Velociti® Series 3 Detectors Technical Specifications STANDARDS For a complete listing of all SYSTEMS compliance approvals and Photoelectric Intelligent Detector: The Velociti°Series Photo t 211TH Detectors a certifications,please visit- - s _ -.- Physical Specifications designed to comply with the following standard: http://www.gamewe - fci.com/en-US/ Height: 2.0 inches(51 mm)installed in B300-6 base UL Standard:UL 268 documentation/Pages/ Diameter: AGENCY LISTINGS AND APPROVALS Listings.aspx 6.1 inches(15.49 cm)installed in B300-6 base These listings and approvals apply to the modules E3 Series®,Velociti®and 4 inches(10.16 cm)installed in B501 base specified in this document.In some cases,certain Gamewell-FCI®are registered Shipping Weight: 3.4 oz(96.4 g) modules or applications may not be listed by certain trademarks of I Honeywell Operating Temperature Range: approval agencies,or listing may be in process. Photo:32°F to 122°F(0°C to 50°C) Consult factory for latest listing status. UL®is a registered trademark UL:S2332 of Underwriter's Laboratories (--22 0°C to 770°C) Photo in Duct Applications: F tF FM:3023594 Inc. C70° Photo with Thermal:32°F to 100°F(0°C to 38°C) MEA FDNY:COA-219-02-E Vol.VI This document is not intended used installation Operating Humidity Range: 10%to 93% CSFM:7272-1703:0501 to beoses.for try to our non-condensing ISO 9001 Certification peup-to- date keep o Rate-of-Rise Detection:Responds to greater than pdproduct information accatu cannoto 15°F/minute or 135°F(8.3°C/minute or 57°C cover all specific applications or anticipate all requirements. Air Velocity Range: 0 to 4,000 ft/min rlpeciateiansaruireents. (0 to 1219.2 m/min) change without notice. Electrical Specifications Voltage Range: 15 to 32 VDC Standby Current(@ 24 VDC): 200 UA(one communication every 5 seconds with green LED enabled) Max Alarm Current(max.): 2 mA C 24 VDC(one communication every 5 seconds with red LED enabled) Max Current(max.): 4.5 mA C 24 VDC(one communication every 5 seconds with amber LED enabled) Isolator Load Rating: 0.0063 For more information Learn more about Gamewell-FCI's Velociti®Series 3 Detectors and other products available by visiting www.Gamewell-FCl.com Honeywell Gamewell-FCI 12 Clintonville Road Northford,CT 06472-1610 203.484.7161 9020-061.7 I K 104/2018 Honeywell www.honeywell.com ©2018 Honeywell International Inc. Gamewe MS-1 Series ' FIRE CONTROL INSTRUMENTS by Honeywell Description Non-Coded, Manual The Gamewell-FCI, MS-7 Series manual fire alarm Fire Alarm Stations sta- tions are available in a wide variety of configurations. The Stations comply with the Americans with Disabilities Act F _ (ADA) 5-lb. maximum pull force requirement. Operating instructions and Braille text are engraved in the handle.All R stations have a key lock/reset which is keyed alike with Gamewell-FCI fire alarm control panels and other manual 1 P1JSti IN fire alarm stations. r!���twry i MS-7AF Velociti Addressable Station The MS-7AF Velociti®Series addressable station is a dou- ble action station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable controlewe - 'b panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated.*The sta- tion MS-7 features screw terminals. Features MS-7ASF Velociti Addressable Station The MS-7ASF Velociti® Series addressable station is a • Addressable stations compatible with all Gamewell-FCI single action station designed for installation in the signal- analog addressable fire alarm controls ing line circuit of Gamewell-FCI analog addressable con- trol panels. Activation of the station causes its assigned • Conventional stations suitable for use with any UL® address to register at the control panel. The door contains Listed control panel an LED which flashes green in normal condition and lights steady red when the station has been activated.*The sta- • Both single and double action stations available tion features screw terminals. The Velociti®Series stations use a communication proto- • Tumbler lock for test and reset keyed alike with col that substantially increases the speed of communica- tion Gamewell-FCI controls between the sensors and certain Gamewell-FCI • analog addressable fire alarm controls. These devices Surface or semi-flush mounting operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor • Shock and vibration resistant stops the group poll and focuses on the single device. The net effect is response speed up to five times greater than • Stations(MS-7LOB)Listed for outdoor applications earlier designs. • Complies with ADA pull force requirements MS-7 Double Action Station *Only the red LED is operative in panels that do not oper- The MS-7 double action station is used with conventional ate in Velociti mode. fire alarm control panels. It features a set of single pole contacts and screw terminals for connection to an initiating circuit. An Compa Velodti®is a registered trademark of Honeywell International Inc. ISO 9001-2000nY .SGNAUNG UL is a registered trademark of Underwriter's Laboratories Inc. LEXAN®is a registered trademark of GE Plastics,a subsidiary of General FM IEA Electric Company. LISTED APPROVED S2465 9023591 67.02-E WWI 0715003e4:261 GAMEWELL-FCI 1 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2010 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0616 Rev.D page 1 of 2 MS-7S Single Action Station Specifications The MS-7S single action station is used with conventional fire alarm control panels. It features a set of single pole Material: Lexan® contacts and wire leads for connection to an initiating circuit. Contact Ratings: 0.25 amps. @ 30 VACNDC MS-7SP Double Action Station (resistive) The MS-7SP is a double action station similar to the MS-7 Dimensions: 5 5/8" H x 4 1/4"W x 1 1/4" D station, with the additional feature of both English and ( cm) Spanish instructions molded into the unit. Operating Temperature MS-7LR Dual-action Agent Release Station (MS-7AF,MS-7ASF): 32°to 120°F(0°to 49°C) (MS-7LOB): -30°to 150° F(-35°to 66°C) The MS-7LR is designed for use with the Gamewell-FCI Relative Humidity fire alarm control panels with releasing capabilities and (MS-7AF,MS-7ASF): 10 to 93%(non condensing) Flex Series releasing systems. It features a set of single pole contacts and screw terminals for connection to an ini- (MS-7LOB): 85%±5%@ 86°±3.6° tiating circuit. (30°±2°C) Alarm Current: .0030 amp. 0.007 for LED MS-7LRA Agent Release Station with Abort Supervisory Current The MS-7LRA is designed for use with the Gamewell-FCI (MS-7AF,MS-7ASF): .00030 amps. fire alarm control panels with releasing capabilities and Flex Series releasing systems where system abort capabil- ities are required. It consists of an MS-7LR mounted on a on plate with an abort switch and LED indicators for system normal, and system activated status. Part Number Description MS-7LOB Double Action Station MS-7 Double action station (Listed for Outdoor Applications) MS-7AF** Velociti addressable double action The MS-7LOB station must be mounted on a Model SB-I/O station backbox. In retrofit applications,the station is UL Listed for MS-7ASF** Velociti addressable single action station use with the WP-10 backbox. It is intended for use with MS-7S Single action station,wire leads conventional control panels and has a set of single pole MS-7SP Double action station, English and contacts and screw terminals. Spanish instructions MS-7LR Agent release station,dual-action Mounting MS-7LRA Agent release station with abort switch, The MS-7 interior stations may be surface mounted or LED indicators,dual-action semi-flush mounted on a standard double-gang, or 4-inch MS-7LOB Double action station, outdoor use (10.2 cm)square electrical box.An optional trim ring (Includes SB-I/O-Indoor/outdoor use (BG12TR)may also be used for semi-flush mounting. backbox) SB-I/O Indoor/outdoor use backbackbox NYC-Plate e backbox rfa 0 Succ The NYC-Plate provides the backplate for the manual pull SB-1SB-bBG1Trimuring for semi-flush mount, plastic station. (See Figure 1). NY-PLATE NYC backplate for manual pull station **For use with the Gamewell-FCI analog addressable control panels only. FIRE PUSH 1N tk{t(i PULL OOW N� i jIIIIIIIIIII716 A Figure 1 NYC-Plate GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9020-0616 Rev.D page 2 of 2 www.gamewell-fci.com J • #00-04sk.„., Gameweli GFPS-9 " j' FIRE CONTROL INSTRUMENTS by Honeywell Description Gamewell-FCI Power Supply 9 The Gamewell-FCI Power Supply 9 (GFPS-9) panel provides two(2)Class A, Style Z, or four(4) Class B, Style Y notification appliance circuits. Each circuit is rated at 3 amperes, with a total capacity of 9 amperes per panel. These circuits may be programmed to activate by groups or various combinations by connection to one (1) or two (2) existing Class A or B notification appliance circuits with operating voltages ranging from 9 to 30 VDC. Either non- coded or coded operation is possible. In addition, the GFPS-9 can provide a temporal pattern output from a non- coded input. A- R N A unique feature allows for programmable synchronized- outputs for strobes by three(3)different major manufacturers,System Sensor, Faraday,or Gentex. GFPS 9 Features The GFPS-9 contains its own battery charger capable of maintaining batteries of up to 33 AH. The cabinet provides • UL Listed as a fire alarm accessory for use with any space for a set of 7 A/H batteries. It is supervised for ground fault, over-current, open circuits and low batteryGamewell-FCI or other UL Listed fire alarm controls. Two(2)Class A(Style Z),or four(4)Class B(Style Y) conditions. These conditions light the appropriate trouble LED and automatically open the notification a liance cir- notification appliance circuits. pp Programmable temporal pattern output including cuit used for activation, transmitting a trouble signal to the ANSI S3.41. main fire alarm control panel.The ground fault detection • High current 9 amp.total output. circuit may be disabled. • Integral strobe synchronization feature for strobes by The unit contains a set of dry, Form "C" trouble actuated three(3)manufacturers. •auxiliary contacts, rated 2.5 amp. @ 24 VDC (resistive). Integral ground fault detection. • Form Transfer of these contacts for AC power failure is program- "C"trouble contacts with delayed AC failure mable and can be delayed for a period of six(6)hours.This indication. delay feature may be disabled. A power limited,non-resettable auxiliary power output up to three (3) amperes is also available. The panel can be pro- grammed via DIP switch to disconnect this output from the batteries 30 seconds after AC power failure, in order to avoid running down the batteries from current devices such as door holders,etc. An ISO 9000-2000 Company 96N L1HC 0 LISTED GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2007 by Honeywell International Inc. All rights reserved. Www.gamewell-fci.com 9020-60236 Rev.A page 1 of 2 Specifications Ordering Information Operating Power: 120 VAC,3.6 amp.60 Hz Model Description Standby Battery GFPS-9 Gamewell-FCI Power Supply-9 Circuit: 24 VDC(nominal)7 ampere/ hours, max. Supervisory Current: 0.075 amp. Alarm Current: 0.175 amp. (excluding notification appliances) Alarm Output: 9.0 amp. max. @ 24 VDC (nominal) Dimensions: 16"H x 12.25"W x 3" D (40.64 x 30.88 x 7.62 cm) Operating Temperature: 32°to 120°F(0°to 49°C) Relative Humidity: 10 to 85% @ 86°F (non-condensing) GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161•Fax:(203)484-7118 9020-60236 Rev.A page 2 of 2 www.gamewell-fci.com ` .00-0.444„.. Gamewell I-Series cm FIRE CONTROL Fr' INSTRUMENTS Indoor Horns, Strobes, by Honeywell and Horn Strobes Description Indoor Selectable-Output Horns, The L-Series audible visible notification products offer the Strobes, and Horn Strobes for most versatile and easy-to-use line of horns, strobes, and Wall Applications horn strobes in the industry. In addition, this product includes lower current draws and a modern aesthetic design which reduce installation times and maximize prof- its. The following devices offer a variety of design options, so that the L-Series can be used for any application requirement. • White and red plastic housings. • Standard and small footprint devices. x • Plain, FIRE, and FUEGO-printed devices. ' Similar to the entire L-Series product line, the wall-mount `�' ' horns, strobes, and horn strobes include a variety of fea- tures that increase their application versatility while simpli- tying the installation. All devices offer a plug-in design so that there is minimal intrusion into the backbox. These fea It tures make installations fast and foolproof while eliminating costly and time-consuming ground faults. To further simplify the installation and protect devices from Wall Horns/Horn Strobes construction damage, the L-Series uses a mounting plate for all standard and compact models that include an on- board Features shorting spring. This feature allows Installers to test • wiring continuity before the device is installed. • Listed for wall mounting only. Installers can also easily adapt devices to suit a wide Offers small profile devices for horns and horn strobes. range of application requirements using the following fea- • Provides an automatic selection of 12-or 24-volt tures: operation at 15 and 30 candela. • Field-selectable candela settings. • Supports a rotary switch for horn tone and two volume • Automatic selection of 12-or 24-volt operation. • Rotary switch for horn tones with two volume selections. selections. • Produces horn rated at 88+dBA at 16 volts. L-Series Specifications • Uses field-selectable candela settings on wall units: Architect/Engineer Specifications - 15 -30 -75 -95 General - 110 - 135 -185 The L-Series standard horns, strobes, and horn strobes • Includes a mounting plate for all standard and all corn- shall mount to any of the following enclosures: pact wall units. • standard 2 x 4 x 1 7/8-inch backbox • Contains a mounting plate with a shorting spring that • standard 4 x 4 x 1 1/2-inch backbox checks the wiring continuity before device installation. • 4-inch octagon backbox • double gang backbox • Features a plug-in design with minimal intrusion into the backbox. The L-Series compact products shall mount to a single- •gang 2 x 4 x 1 7/8-inch backbox. A universal mounting Designed with stamper-resistant construction. plate shall be used for mounting ceiling and wall products • Built with an updated modern design. for all standard models and a separate universal mounting Supports electrical compatibility with the existing plate shall be used for mounting wall compact models. SpectrAlert and the SpectrAlert Advance products. The notification appliance circuit wiring shall terminate at • Compatible with System Sensor synchronization the universal mounting plate. Also, the L-Series products, protocol. when used with the Sync•Circuit, Module accessory, shall SIGNALING be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. $ LISTED APPROVED •� t�1 PENDING pis, GAMEWELL-FCI 17:1171111117 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2016 by Honeywell International Inc. All rights reserved www.gamewell-fci.com 9021-60929 Rev.A page 1 of 4 J L-Series Specifications(Continued) Physical/Electrical Specifications Architect/Engineer Specifications (Continued) General (Continued) Standard Operating to 49°C)° 120 to 32°F 120°F When it is used with the Sync•Circuit Module,the following Temperature: 32 (0°C occur: Humidity Range: 10 to 93%non-condensing • 12-volt-rated notification appliance circuit outputs shall Strobe Flash Rate: 1 flash per second operate between 8.5 and 17.5 volts. Nominal Voltage: Regulated 12 DC or • 24-volt-rated notification appliance circuit outputs shall regulated 24 DC/FWR1 operate between 16.5 and 33 volts. Operating Voltage Rangel: 8 to 17.5 V(12 V nominal)or The Indoor L-Series products shall operate between 32 16 to 33 V(24 V nominal) and 120 degrees Fahrenheit from a regulated DC or full- Operating Voltage Range wave rectified unfiltered power supply. Strobes and horn (MDL3)Sync Module: 8.5 to 17 V(12 V nominal)or strobes shall have the following field-selectable candela 16.5 to 33 V settings: (24 V nominal) • 15 • 30 • 75 • 95 Input Terminal Wire Gauge: 12 to 18 AWG • 110 • 135 • 185 Wall-Mount Dimensions Strobe (including lens): 5.6 L x 4.7 W x 1.25 D(143 The strobe shall be an L-Series Model listed to mm Lx119 mm W x 32 mm D) UL Standard 1971 and shall be approved for fire protective Compact Wall-Mount service. The strobe shall be wired as a primary-signaling Dimensions: 5.26" L x 3.46"W x 1.93" D notification appliance and comply with the Americans with (including lens) (133 mm L x 88 mm W x 49 mm D) Disabilities Act requirements for visible signaling appli- Horn Dimensions: 5.6 L x 4.7 W x 1.25 D(143 ances, flashing at 1 Hz over the strobe's entire operating mm Lx119 mm W x 32 mm D) voltage range. The strobe light shall consist of a xenon Compact Horn flash tube and associated lens/reflector system. Dimensions: 5.25"L x 3.45"W x 1.25" D (133mm L x 88mm W x 32mm D) Horn Strobe Combination Notes: The horn strobe shall be an L-Series Model listed 1. Full Wave Rectified(FWR)voltage is a non-regulated, to UL Standard 1971 and UL Standard 464 and shall be time-varying power source that is used on some approved for fire protective service. The horn strobe shall power supply and panel outputs. be wired as a primary-signaling notification appliance and 2. P, S, PC, and SC products will operate at 12 V comply with the Americans with Disabilities Act require- nominal only for 15 cd and 30 cd. ments for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audible options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a Sync•Circuit model MDL3 listed to UL Standard 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also,while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch backbox. The module shall also control two Style Y (Class B) circuits or one Style Z(Class A)circuit.The module shall synchronize multiple zones. Daisy-chaining two or more synchroniza- tion modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. GAMEWELL-FCI 12 Clintonville Road,Northford,CTW2 --16r110 USAf•C ecom3)484-7161 •Fax:(203)484-7118 9021-60929 Rev.A J page 2 of 4 UL Current Draw Table 2 lists the UL maximum Horn current draw. Table 1 lists the UL maximum Strobe current draw. 8-17.5 8-17.5 Volts 16-33 Volts Sound Volts 16-33 Volts Candela DC DC FWR Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 135 N/A 172 209 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 Table 1: UL Maximum Strobe Current Draw(mA 3.1 KHz Non-Temporal Low 28 29 54 RMS) Ceded High 43 47 54 13.1 KHz Coded High 42 43 54 Table 2: UL Max. Horn Current Draw(mA RMS) UL Current Draw Data Table 3 lists the maximum UL Current Draw(mA RMS)allowed for 2-Wire Horn Strobes, candala range(15-115cd). 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd EM Temp Hi 98 158 54 74 121 142 162 196 245 EM Temp Low 93 154 44 65 111 133 157 184 235 EM Cont Hi 106 166 73 94 139 160 182 211 262 EM Cont Low 93 156 51 71 119 139 162 190 239 3.1K Temp Hi 93 156 53 73 119 140 164 190 242 3.1K Temp Low 91 154 45 66 112 133 '160 185 235 3.1K Cont Hi 99 162 69 90 135 157 175 208 261 3.1k Cont Low 93 156 52 72 119 138 162 192 242 16V FWR FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd EM Temp Hi 83 107 156 177 198 234 287 EM Temp Low 68 91 145 165 185 223 271 EM Cont Hi 111 135 185 207 230 264 316 EM Cont Low 79 104 157 175 197 235 283 3.1K Temp Hi 81 105 155 177 196 234 284 3.1K Temp Low 68 90 145 166 186 222 276 3.1K Cont Hi 104 131 177 204 230 264 326 3.1k Cont Low 77 102 156 177 199 234 291 Table 3: UL Max. Current Draw(mA RMS), 2-Wire Horn Strobe, Candela Range(15-115 cd) Horn Strobe Tones and Sound Output Data Table 4 lists the horn strobe tones and sound output data. 8-17.5 16-33 Switch Volts Volts I Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9 Coded High 85 90 90 10 3.1 KHz Coded High 84 89 89 Table 4: Horn Strobe Tones and Sound Output Data GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 www.gamewell-fci.com 9021-60929 Rev.A page 3 of 4 • L Series Dimensions L Series Dimensions _ 1.91 3.46 1.25 3.46 -- 1.25 1-77.-110 01 - .r"-----, -„ _ :N 01 M I NN1 01.4 .16 X 11til ^ 5.27 III 5.27 1 I a-.. it, La , ' lit Figure 1 Compact Combo Figure 2 Compact Horn L Series Dimensions L Series Dimensions I. 4.70 , _ 4.70 _ 1 1.91 .91 1.25 , .-- 1.25 re----q16 �. 1 /1 +Ir-1' /i 1 5.67i iiJ 567 1 l', 4• w II. Figure 3 Standard Combo Figure 4 Standard Horn L-Series Ordering Information L-Series Ordering Information Horns Wall Horn Strobes Part Number Description Part Number Description HRL Standard Horn, Red P2RL 2-Wire, Standard Horn Strobe, Red HWL Standard Horn,White P2WL 2-Wire, Standard Horn Strobe,White HGRL Compact Horn, Red P2GRL 2-Wire, Compact Horn Strobe, Red HGWL Compact Horn,White P2GWL 2-Wire, Compact Horn Strobe,White Accessories P2RL-P 2-Wire, Standard Horn Strobe,Red, Plain TR-2 Universal Wall Trim Ring Red P2WL-P 2-Wire,Standard Horn Strobe,White,Plain TR-2W Universal Wall Trim Ring White P2RL-SP 2-Wire,Standard Horn Strobe,Red, SBBRL Standard Wall Surface Mount Backbox, FUEGO Red P2WL-SP 2-Wire, Standard Horn Strobe,White, SBBWL Standard Wall Surface Mount Backbox, FUEGO White Wall Strobes SBBGRL Compact Wall Surface Mount Backbox, SRL Standard Strobe, Red Red SWL Standard Strobe,White SBBGWL Compact Wall Surface Mount Backbox, SGRL Compact Strobe, Red White SGWL Compact Strobe,White Notes: SRL-P Standard Strobe, Red, Plain All-P models have a plain housing SWL-P Standard Strobe,White, Plain (no"FIRE"marking on cover). SRL-SP Standard Strobe, Red, FUEGO All-SP models have"FUEGO"marking on cover. SWL-CLR-ALERT Standard Strobe,White,ALERT All-ALERT models have"ALERT"marking on cover. GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9021 60929 Rev.A page 4 of 4 www.gamewell-fci.com UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output(dBA) candela ratings must be reduced in accordance with this table. 8-17.5 16-33 24-Volt Nominal Strobe Output(cd) Switch Sound Volts Volts Reverberant Anechoic Listed Candela Candela riding at—40°F Position Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 75 4 Non- High 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 78 78 85 85 90 90 98 98 110 110 Temporal 115 115 6 Non- Low 135 135 Temporal 75 75 81 81 88 84 96 92 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. AVDSO1201 SpectrAlert Advance Diagrams 4.7'= 2.5"--r NO Mir Mr MI IIIfr5.6' � � T71 , ------L_ IT: e IIII ..— Wall-Mount Horn Strobes ^)���� Wall Plastic Weatherproof Back Box 611, I ' I"®®®1i►�11 tov . r- i ilil i IIIIIII 1 Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P2RK*t 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor,120 V(includes plastic weatherproof back box) Wall Strobes SRK*t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK*t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK*t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK*t Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. S ©2012 System Sensor. \//STEM 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change vnthout notice.visit systemsensoccom S +E�SO�x Phone:800-SENSOR2•Fax:630-377-6495 for current product Information,including the latest version of this data sheet. avos01201•si,2 SYSTEM �.$ SENSOR® Outdoor Selectable ' 417; - . Output Horns, Strobes, and Horn Strobes for Wall Applications SPECTRA-left SpectrAlert®Advance outdoor audible visible products Amilutaidatillmani are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X,IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from-40°F to 151°F • Field-selectable candela settings: 15, 15/75,30,75,95, 110, 115, 135, 150,177,and 185 Like the entire SpectrAlert Advance line,outdoor horns,strobes, and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation.First, 15/75 candela field-selectable settings,including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from-40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mountina,___olate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature T removable side flanges and improved resistance to saltwater swum ^' corrosion.Knock-outs located on the back eliminate the need to drill CEO"� holes for screw-in mounting.Plastic and metal weatherproof back �L ® M� lei boxes come with 34-inch top and bottom conduit entries and 3/4-inch USTED 300-1653187(outdoor strobes) approved 7125-1653:168 morn st obes, knock outs at the back.A screw-in NPT plug with an 0-ring gasket S4011(chimes,horn strobes,horns) MPROVED PP chime strobes) S3593(outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653:189(horns,chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn,Strobe,and Horn Strobe Specifications Architect/Engineer Specifications SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit""Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between-40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15,15/75,30,75,95,110, 115,135,150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7"L x 5.1"W x 2.0"D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201