Loading...
Report (40) � NE AccuSpec V4.22.2 Transaction #: 12764284 JOB TITLE: Reece (Tigard) Date: 05/01/2019 Approved By: Submittal review and approval required prior to listed unit(s) being released for production and shipment. Unit(s) configured based on information provided. The Approver is responsible for ensuring the units, options, and accessories meet the job specifications. MODINE AccuSpec V4.22.2 SUBMITTAL SCHEDULE & DATA Gas- and OH-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Job Name: Reece (Tigard) Date: 05/01/2019 Location: Engineer: Submitted by: Kyle Cereghino Architect: Contractor: Unit Tag UH-1, UH-2, UH-3 Model Number HD 30AS0111FBAN Quantity of Units 3 Btu/Hr Input 30,000 Btu/Hr Output 24,600 CFM 505 Altitude 0-2000 Temperature Rise (degrees F) 45 External Static Pressure (E.S.P) 0.00 Total Static Pressure (T.S.P.) 0.00 Gas Type Natural Gas Control Type Single Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry Supply Voltage 115/60/1 Control Voltage 24V Motor HP 1/15 Motor RPM 1550 Blower RPM N/A Heat Exchanger Type Aluminized Steel Heat Exchanger/Burner Unit Efficiency % 82.0 Options & Accessories (See Attached Pages) Remarks ?ODINE gib' AccuSpec V4.22.2 SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters and Infrared Heaters Model Description Qty Tag 3 UH-1, UH-2, HD 30A50111FBAN Propeller Unit Heater UH-3 3 UH-1, UH-2, 53140 HD 30A50111FBAN UH-3 4 ,j OOINE AccuSpec V4.22.2 HD MODEL NOMENCLATURE 1,2,3 4,5,6 i 7 8 9,10 11,12 13 14 15 16 I HD 30 1 A S 01 11 F B A N j 1,2,3 - Product Type HD - Power Vented Propeller Unit 4,5,6 - Furnace Input Rating 30 - 30,000 Btu/hr Input 7 - Heat Exchanger Type A - Aluminized Steel Heat Exchanger and Burner 8 - Pilot Ignition S - Direct Spark Ignition 9,10 - Motor and Drive Code (Power Code) 01 - 115V motor 11,12—Gas and Valve/Ignition Control Type (Control Code) 11 - Natural, Single Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry 13 — Fan Guard Type F - Finger Proof Fan Guard 14— Development Sequence B - Current 15 — Future A- For Future Use 16—Factory Installed Option N - Click to See ?0DINE AccuSpec V4.22.2 GENERAL PERFORMANCE DATA c us �, o Intertek General Performance Data Model HD 30 At 0' Elevation Btu/Hr. Input 30,000 Btu/Hr. Output 24,600 Entering Airflow (CFM) 505 Outlet Velocity 523 Air Temp. Rise (°F) 44 Mounting Height (Max Ft.)1 10 Heat Throw (Max. Mtg. Ft.)2 25 Unit Total Power (Amps) 3.75 As Configured at 0-2000 Ft. Elevation Btu/Hr. Input 30,000 Btu/Hr. Output 24,600 Configured Air Temp Rise (°F) 45 Motor Data Horse Power 1/15 RPM 1550 Type S.P. Motor Amps at 115V 2.40 Clearances to Combustibles Top and Bottom 1" Vent Connector 4" Access Side 18" Non-Access Side 1" Rear 18" 1 At 65°F ambient and unit fired at full-rated input. Mounting height as measured from bottom of unit. 2 Heat Throws are calculated at 65°F ambient with a 45°F air temperature rise with the unit mounted at a maximum mounting height of 10 feet. f ?0DINE AccuSpec V4.22.2 DIMENSIONS - UNIT Model HD Dimensions 13.5 BETWEEN 3.8'16 MOUNTING HOLES MOUNTING HOLES V) ON 1N.W BETWEEN 3B"16 MOULHOLES (MODEL SIZES 1CO AND 125 ONLY) TYP 3/8 ai"LONA (MODEL SIZES#DD AND 125 ONLY) a MOUNTING 6 r--_ f0' —POWER VENTER BRACfcST ADIU3TASLE VENT PIPE SIZE 30 76 33" IA WENS j 1� CONNECTION ELECTRIC AL jlE CT NN ECTION Iiiii GAS 1 �' � � E _�.IEM,_,A 5� ill COH NFL i1pN _ q • t Bp pPEN1H6 . Y ik f� 1 � .YP'tP IM 9 1 ' 1 r �.;i ,._,✓,:. pay • C 6OPENINO w•—•—N U ACCESS PANEL 1 ACCESS VIEW REAR VIEW Model Size HD30 Dimensions (in inches) A 26.8 B 12.2 C 16.5 D 14.9 E 10.1 F 7.5 G 18.5 H 7.6 I 28 J 22 Vent Connector 3 Diameter Gas Connection 1/2 Diameter Fan Diameter 10 Approx. Shipping 55 lbs. Weight Standards All unit(s) shall include: C.S.A. (Canadian Standards Association) design certification for use in both the US and Canada to the ANSI Z83.8 - latest revision, standard for "Gas Unit Heater and Gas-Fired Duct Furnaces" for safe operation, construction, and performance Mechanical Configuration Furnace(s) section with 82% minimum efficiency provided by an indirect-fired tubular heat exchanger with individually fired tubes for maximum heat transfer with minimal noise of flame ignition/extinction. Venting Arrangement The venting shall be a power exhausted arrangement. The unit shall be tested to insure proper ignition when the unit is subjected to 40 mile per hour wind velocities. The unit shall also include a factory mounted differential pressure switch designed to prevent main burner ignition until positive venting has been proven. Unit Casing The unit heater(s) casing shall be constructed of not less than 22 gauge aluminized steel with minimization of exposed fasteners. All exterior casing parts shall be cleaned of all oils and a phosphate coating applied prior to painting. The exterior casing parts shall then be painted with an electrostatically applied baked-on gray-green polyester powder paint (7-mil thickness) for corrosion resistance. The unit shall be furnished with horizontal air deflectors. The deflectors are adjustable to provide for horizontal directional airflow control (up or down). Furnace Section The heat exchanger(s) shall be made of 18 gauge aluminized steel tubes and headers. The thermal efficiency of the unit(s) shall be a minimum of 82% efficient for all air flow ranges. Each heat exchanger tube shall be individually and directly flame-fired. The heat exchanger tube shall be crimped to allow for thermal expansion and contraction. The flue collector box shall be made of 20 gauge aluminized steel. The heat exchanger(s) seams and duct connections shall be certified to withstand 0.9" W.C. external static pressure without burner flame disturbance. The burner(s) shall be in-shot type, directly firing each heat exchanger tube individually and is designed for good lighting characteristics without noise of extinction for both natural and propane gas. The ignition controller(s) shall be 100% shut-off with continuous retry. The gas pressure shall be between 6-7" W.0 for natural gas. The solid state ignition system shall directly light the gas by means of a direct spark igniter each time the system is energized. i I The unit gas controls shall be provided with the following: Single-stage gas controls with a single-stage combination gas control, an ignition control. The unit fires at 100% full fire based on a call for heat from a room thermostat. An automatic reset high limit switch mounted in the air stream to shut off the gas supply in the event of overheating. A time delay relay that delays the start of the air mover to allow the heat exchanger a warm-up period after a call for heat. The time delay relay shall also continue the air mover operation after the thermostat has been satisfied to remove any residual heat in the heat exchanger. The unit shall be orificed for 0-2000 feet elevation above sea level. Electrical All electrical components shall carry UL, ETL, or CSA certification. A low voltage terminal board shall be provided for direct wiring connection to an external thermostat. A single 115V to 24V step down transformer shall be provided for all unit controls. Air Mover The motor horsepower shall be 1/15 H.P. The motor wiring shall be in flexible metal BX conduit. The motor shall be controlled by a time delay relay. Propeller models shall meet the following requirements: The motor type shall be Single-Speed, Open Drip Proof (ODP). The air mover motor shall be a 115V motor. Mounting The unit shall be equipped with mounting brackets to allow for threaded rod suspension or to be bolted directly to the ceiling support structure allowing 1" of top clearance. Accessories The following field installed accessory control devices shall be provided with the unit: