Report (52) Mcc.?ry\ct--C)crs3 L 5 S� c 1 .vQsy SUBMITTAL Job Title: Reece (Tigard) Elevation: (ft) 108 Date: 5/01/2019 Submitted By: Kyle Cereghino JOHNSON AIR PRODUCTS 2220 SE 9TH AVE PO BOX 15098 PORTLAND, OR 97293 US Phone: (503)234-5071 Fax: (503)233-0451 Email Address: kcereghino@johnsonair.com SUBMITTAL NOTES: ** Roof Exhaust Fan Submittal *" GREENHECK ® Building Value in Air. P.O. Box 410 Schofield, WI 54476 (715) 359-6171 FAX (715) 355-2399 www.greenheck.corn Generated by:kcereghino@johnsonair.com CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj Page 1 of 22 , GREENHECK Printed Date: 05/(Tigard)1 /201 Job: Reece ® Building Value in Air. Mark: Restroom Exhaust Model: G-099-VG 0 24.40 Model: G-099-VG Direct Drive Centrifugal Roof Exhaust Fan 1 23.70 1.75 35.70 DimensionalJ Quantity 1 t (12.00) Weight w/o Acc's(Ib) ' 35 Weight w/Acc's(Ib) I 37 Roof Opening(in.) 1 14.5 x 14.5 —19.00 SQ-- OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR. Performance 1.0 0.25 Requested Volume(CFM) 800 . Actual Volume 800 Total External SP(in.(CFM) ) 0.25 0.8 ` r 0.20 9 – Fan RPM 1 1264 1264FRPM I I Operating Power(hp) 1 0.1 a, Elevation(ft) 1, 108 0.6 0.15 a C 0 Airstream Temp.(F) 70m` I 3 Air Density(Ib/ft3) 0.075 n b1 0 --1--------------- -------n----- - � Tip Speed(ft/min) 3,702 2 0.4 -_.- 0.10 Static Eff.(%) 33 c EE cofi •• -- ----- —.0 0.05 Qa Yste.t _._. Motor0.0 _Li- H-1-1-1 'I li SII lit I111 . I 0.00 Motor Mounted Y 0 1 2 3 4 5 6 7 8 9 10 Size(hp) 1 1/4 Volume(CFM)x 100 VoltICY age 115/60/1 Enc osuseODP v Operating Bhp point Motor RPM l 1725 0 Operating point at Total External SP Fan curve 1 -.._ _.-System curve Windings Brake horsepower curve FLA(Amps) 2.85 Notes: All dimensions shown are in units of in. *NEC FLA-based on tables 430.248 or 430.250 of Qmca National Electrical Code 2014.Actual motor FLA may vary, CCEERRTVFIED Sound Power by Octave Band for sizing thermal overload,consult factory. MUMS SoundLwA-A weighted sound power level,based on ANSI S1.4 Dnp Data 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones dBA-A weighted sound pressure level,based on 11.5 d6 attenuation per Octave band at 5 ft-dBA levels are not D ' oe YIY Inlet 71 73 74 65 61 59 52 46 69 58 8.8 licensed by AMCA International Sones-calculated using AMCA 301 at 5 ft Generated by:kcereghino@johnsonair.com CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj Page 2 of 22 GREENHECK Printed Date: 05/01/2019 Building Value in Air. Job: Reece (Tigard) Mark: Restroom Exhaust Model: G-099-VG Model: G-099-VG Direct Drive Centrifugal Roof Exhaust Fan Tag:EF-1 Standard Construction Features: -Aluminum housing-Backward inclined composite(sizes 60-95)or aluminum (sizes 97-300)wheel-Aluminum curb cap with prepunched mounting holes- Birdscreen-Ball bearing motors(sizes 85-300 and all Vari Green),sleeve bearing motors(sizes 60-80)-Motor isolated on shock mounts-Corrosion resistant fasteners Selected Options &Accessories: Motor-Vari-Green EC motor Control-Dial for balancing UL/cUL 705 Listed-"Power Ventilators" Switch,NEMA-1,Toggle,Shipped with Unit Junction Box Mounted&Wired Unit Warranty: 1 Yr(Standard) Generated by:kcereghino@johnsonair.com CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj Page 3 of 22 • nifGREENHECK Printed Date: 05/01/2019 Job: Reece (Tigard) ® Building Value in Air. Mark: Restroom Exhaust Model: G-099-VG Disconnect Switch Enclosure Rating: NEMA-1 Standard Construction Features: Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor corrosion protection design tests. The rod entry test is intended to simulate incidental contact with enclosure equipment. Enclosure is equipped with provision to lockout in the off position with customer supplied lock. Disconnect Switch Configuration Type: Toggle Motor Size: 1/4 hp Voltage: 115 UL Listed: Yes Manufacturer: Pass and Seymour Cycle: 60 Amperage: 15 CSA Approved: Yes Overload Protection: None Phase: 1 Switch Pole(s): 1 Rating: 1/2 hp Junction Box Mtg.: Mounted and Wired RPM: 1725 Exp. Resist. Wiring: None Switch Mounting: Shipped With Unit Electrical Drawing Details 00.28 Wiring (4 HOLES) Schematic O • O 4.35 I 1.06 \ • ' • O 1.65 j 0 1 I \ 0.72 —1 2.00 1.06 2.50 — ) Notes:All dimensions shown are in units of in. Generated by:kcereghino@johnsonair.com Page 4 of 22 CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj INGREENHECK Printed Date: 05/01/2019 Building Value in Air. Job: Reece (Tigard) Mark: Restroom Exhaust Model: G-099-VG Assembly Drawing Type: Direct Drive Centrifugal Roof Exhaust Fan SUGGESTED ROOF OPENING . 1 12.00 14.50 SQ SQ RECOMMENDED EXHAUST DUCT SIZE i. A 024.40 23.70 J L 1.75 35.70 t! 1 (12.00) 1 9.00 SQ DUCT DIMENSIONS ARE LARGEST POSSIBLE DUCT TO FIT THROUGH CURB. CONSULT SYSTEM DESIGN ENGINEER FOR RECOMMENDED DUCT SIZE. OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR. Notes:All dimensions shown are in units of in.. Generated by:kcereghino@johnsonair.com CAPS 4.29.1458 Y:1KyleCereghino\Reece(Tigard).gfcj Page 5 of 22 ® Printed Date: Reece 05/01(Ti/2019 IGREENHECK Job: gard) Building Value in Air. Mark: Restroom Exhaust Model: G-099-VG Vari-Green Motor & Control Options An EC motor that uses AC input power and internally converts it to DC power. Potentiometer (dial) mounted on the motor enclosure adjusts the speed (RPM) down 80%. Vari-Green motors feature a soft-start and inherent thermal and current protection built into each unit. Inrush current at start up is eliminated and the motor will automatically reduce speed or turn off if overloaded or it becomes too hot. SLAC- Motor Configuration > WELT VOLTAGE WHITE Input Voltage: 115 ` GREEN GROUND Speed Reference: Dial on Motor Permanent Dial: Yes SPEED CCNTROL Control Configuration / � Control Type: N/A I + Transformer: None VARI-GREED Motor Generated by:kcereghino@johnsonair.com Page 6 of 22 CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj IGREENHEcK Printed Date: 05/01/2019 Building Value in Air. Job: Reece (Tigard) Mark: Restroom Exhaust Model: G-099-VG G-099-VG Min/Max Fan Curve Performance Requested Actual Volume Volume Total External Fan Operating (CFM) (CFM) SP(in.wg) RPM Power(hp) 800 800 0.25 1264 0.1 1.4 0.28 1725 FRPM 1.2 -- - 0.24 1.0 - 0.20 ( - 0) a+ 0.8 0.16 _c 1264 FRAM ( 0.6 - - o - 0.12 cp CL 0,,,'(\S'' __ -- - ----- a 0.4 0.08 m 0.2 + 0.04 300 r-P'M - _ 0.0 --- -4_..1 ._.i_ ..- ! I 0.00 0 2 4 6 8 10 12 14 Volume (CFM) x 100 A Operating Bhp point O Operating point at Total External SP Fan curve - - — -System curve Brake horsepower curve Generated by:kcereghino@johnsonair.com CAPS 4.29.1458 Y:1KyleCereghino\Reece(Tigard).gfcj Page 7 of 22 Printed Job:Date:Reece 05/01/2019(T E1GREENHECK igard) Building Value in Air. Mark: Restroom Exhaust Model: GPI Roof Curb Model: GPI Material: Galvanized Standard Construction Features: - Roof Curb fits between the building roof and the fan mounted directly to the roof support structure -Constructed of either 18 ga galvanized steel or 0.064 in. aluminum -Straight Sided without a cant-2 in. mounting flange- 3 lb density insulation - Height -Available from 12 in. to 42 in. as specified in 0.5 in. increments. Notes: -The maximum roof opening dimension should not be greater than the"Actual"top outside dimension minus 2 in.. -The minimum roof opening dimension should be at least 2.5 in. more than the damper dimension or recommended duct size. -The Roof Opening Dimension may or may not be the same as the Structural Opening Dimension. - Damper Tray is optional and must be specified. Tray size is same as damper size. - Security bars are optional and must be specified. Frames and gridwork are all 12 ga steel. Gridwork is welded to the frame and the frame is welded to the curb. 17.50 17.50 12.00 21 .50 21 .50 Notes:All dimensions shown are in units of in. Generated by:kcereghino@johnsonair.com Page 8 of 22 CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj 0 GREENHECK Printed Date: 05/01/2019 Building Value in Air. Job: Reece (Tigard) Mark: Mechanical Room Ex Model: G-070-VG Model: G-070-VG '--O19.40--i Direct Drive Centrifugal Roof Exhaust Fan r12.10 j-1.75 Dimensional i j 24.10 Quantity 1 t (12.00) Weight w/o Acc's(Ib) j 17 Weight w/Acc's(Ib) 19 Roof Opening(in.) 10.5 x 10.5 OVERALL HEIGHT MAYBE GRA0 TER DEPENDING ON MOTOR. Performance 0.5 0.25 Requested Volume(CFM) 200 — • Actual Volume(CFM) 200 Total External SP(in.wg) 0.25 0.4 0.20 Fan RPM 1365 1365 F/RpM Operating Power(hp) 0.02 En Elevation(ft) 108 0.3 • "---� C - l's_ -- -• 0.15 Airstream Tem F 70 Air Density(Ib/ft3) I 0.075 Tip StaSpetin Eff.m ) 2,904 m 0.2 a° o " d E ra . 0.10 (%) 45 11 e 203 ` \ m 0.1 Q°� f ° , 0.05 c° Motor 0.0 _ - i i ' l l i i : 1 : 1 . 1 . ]II t� Motor Mounted ' Yes 0.00 0 50 100 150 200 250 300 350 Size(hp) 1/15 Volume(CFM) Voltage/Cycle/Phase, 115/60/1 Enclosure I TENV A Operating Bhp point Motor RPM 1725 o Operating point at Total External SP Fan curve Windings ! 1 System curve FLA(Amps) 1.3 Brake horsepower curve Notes: All dimensions shown are in units of in. "NEC FLA-based on tables 430.248 or 430.250 of amen Sound Power by Octave Band National Electrical Code 2014.Actual motor FLA may vary, WORIDWIDI Sound for sizing thermal overload,consult factory. OERTIiIED 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones LwA-A weighted sound power level,based on ANSI S1.4 RR1rInGt DatadBA-A weighted sound pressure level,based on 11.5 dB sounD per Octave band at Inlet 65 64 59 46 40 39 34 30 54 42 3.2 lliicensed ttenuation by AMCA International 5 ft-dBA levels are not D nron A ! Sones-calculated using AMCA 301 at 5 ft MR nvemnnr�"N wnram N. o\ Generated by:kcereghino@johnsonair.com Eannrn�n 11 C ''' , CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj Page 9 of 22 PrintedDate: / 019Job: Reece05/01(Tigard)nife__ . immmmmmmmmmmmmm•mm•.m.••••m ...miGREENHECK Building Value in Air. Mark: Mechanical Room Ex Model: G-070-VG Model: G-070-VG Direct Drive Centrifugal Roof Exhaust Fan Tag:EF-2 Standard Construction Features: -Aluminum housing-Backward inclined composite(sizes 60-95)or aluminum (sizes 97-300)wheel-Aluminum curb cap with prepunched mounting holes- Birdscreen-Ball bearing motors(sizes 85-300 and all Vari Green),sleeve bearing motors(sizes 60-80)-Motor isolated on shock mounts-Corrosion resistant fasteners Selected Options &Accessories: Motor-Vari-Green EC motor with Dial ONLY(Not capable for field conversion to 0-10) Control-Dial for balancing UL/cUL 705 Listed-"Power Ventilators" Switch,NEMA-1,Toggle,Shipped with Unit Junction Box Mounted&Wired Composite Wheel Material Unit Warranty: 1 Yr(Standard) Generated by:kcereghino@johnsonair.com Page 10 of 22 CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj IPrinted Date: 05/01/2019 Building Value in Air. Job: Reece (Tigard) Mark: Mechanical Room Ex Model: G-070-VG Disconnect Switch Enclosure Rating: NEMA-1 Standard Construction Features: Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor corrosion protection design tests. The rod entry test is intended to simulate incidental contact with enclosure equipment. Enclosure is equipped with provision to lockout in the off position with customer supplied lock. Disconnect Switch Configuration Type: Toggle Motor Size: 1/15 hp Voltage: 115 UL Listed: Yes Manufacturer: Pass and Seymour Cycle: 60 Amperage: 15 CSA Approved: Yes Overload Protection: None Phase: 1 Switch Pole(s): 1 Rating: 1/2 hp Junction Box Mtg.: Mounted and Wired RPM: 1725 Exp. Resist. Wiring: None Switch Mounting: Shipped With Unit Electrical Drawing Details 00.28 (4 HOLES) Wiring Schematic O 4.35 I O 1.06 • O I ' 1.65 ' 0 0.72 2.00111, —i 1.06 2.50 Notes:All dimensions shown are in units of in. Generated by:kcereghino@johnsonair.com CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj Page 11 of 22 Printed Date: 05/01/2019 IGREENHECK Job: Reece (Tigard) Building Value in Air. Mark: Mechanical Room Ex Model: G-070-VG Assembly Drawing Type: Direct Drive Centrifugal Roof Exhaust Fan SUGGESTED ROOF OPENING II8.00 10.50 ISQ SQ RECOMMENDED EXHAUST DUCT SIZE 0 19.40 1.7512.10 24.10 (12.00) 1 1 -- 17.00 SQ DUCT DIMENSIONS ARE LARGEST POSSIBLE DUCT TO FIT THROUGH CURB. CONSULT SYSTEM DESIGN ENGINEER FOR RECOMMENDED DUCT SIZE. OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR. Notes:All dimensions shown are in units of in.. Generated by:kcereghino@johnsonair.com CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj Page 12 of 22 I1GREENHECK Printed Date: 05/01/2019 Building Value in Air. Job: Reece (Tigard) Mark: Mechanical Room Ex Model: G-070-VG Vari-Green Motor & Control Options An EC motor that uses AC input power and internally converts it to DC power. Potentiometer (dial) mounted on the motor enclosure adjusts the speed (RPM) down 80%. Vari-Green motors feature a soft-start and inherent thermal and current protection built into each unit. Inrush current at start up is eliminated and the motor will automatically reduce speed or turn off if overloaded or it becomes too hot. Motor Configuration BLACK INDoT VOLTAGE Input Voltage: 115 WHITE Speed Reference: Dial on Motor �� GREEN GROUND Permanent Dial: Yes SPEED CONTROL � Control Configuration Control Type: N/A + Transformer: None VARI-GREEN. m DRAtaNG# Generated by:kcereghino@johnsonair.com CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj Page 13 of 22 Printed Date: 05/01/2019 LJob: Reece (Tigard) MGREENHECK Building Value in Air. Mark: Mechanical Room Ex Model: G-070-VG G-070-VG Min/Max Fan Curve Performance Requested Actual Total External Fan Operating Volume Volume SP(in.wg) RPM Power(hp) (CFM) (CFM) 200 200 0.25 1365 0.02 0.30 _725 pRp,A j I' 0.5 _ , 0.25 • o 0.4 --- 0.20 1355 FRP Q c , 2_,) 0.3 - - t - 0.15 o a_ a> 0.2 -- 0.10 W 0.1 Max FRPM __ 0.05 BhP ------------ ---- --------- ---- 300- PM A - \ _ 0.0 _ --�_ 0.00 0 50 100 150 200 250 300 350 400 450 Volume (CFM) A Operating Bhp point O Operating point at Total External SP Fan curve - - - -System curve Brake horsepower curve Generated by:kcereghino@johnsonair.com CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj Page 14 of 22 EI GREENHECK Printed Date: 05/01/2019 Job: Reece (Tigard) Building Value in Air. Mark: Mechanical Room Ex Model: GPI Roof Curb Model: GPI Material: Galvanized Standard Construction Features: - Roof Curb fits between the building roof and the fan mounted directly to the roof support structure -Constructed of either 18 ga galvanized steel or 0.064 in. aluminum - Straight Sided without a cant-2 in. mounting flange- 3 lb density insulation - Height -Available from 12 in. to 42 in. as specified in 0.5 in. increments. Notes: -The maximum roof opening dimension should not be greater than the "Actual"top outside dimension minus 2 in.. -The minimum roof opening dimension should be at least 2.5 in. more than the damper dimension or recommended duct size. -The Roof Opening Dimension may or may not be the same as the Structural Opening Dimension. - Damper Tray is optional and must be specified. Tray size is same as damper size. -Security bars are optional and must be specified. Frames and gridwork are all 12 ga steel. Gridwork is welded to the frame and the frame is welded to the curb. 15.50 15.50 4000111110;s0. 12.00 .-41141411111-111111111 19.50 19.50 Notes:All dimensions shown are in units of in. Generated by:kcereghino@johnsonair.com CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj Page 15 of 22 nIGREENHECK Printed Date: 05/01/2019 Job: Reece (Tigard) Building Value in Air. Mark: Gym Exhaust Model: G-099-VG 0 24.40 - Model: G-099-VG Direct Drive Centrifugal Roof Exhaust Fan 23.70 r 1.75 35.70 Dimensional 1 Quantity I 1 (12.00) Weight w/o Acc's(Ib) 35 Weight w/Acc's(Ib) 37 Roof Opening(in.) 14.5 x 14.5 —19.00 SQ-- OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR. Performance 1.0 0.25 Requested Volume(CFM) 900 Actual Volume(CFM) 900 1378 FRPM Total External SP(in.wg) 0.25 0.8 , 0.20 Fan RPM 1378 Operating 0.12 m p 9 Power ' 108 X0.6 0.15 a Elevation(ft) _c Airstream Temp.(F) 70 - a ----------�- P p ) 0.075 n a r'.- \ + cn R o Air DensityIb/ft3) 4,037 i3 0.4 ' � 0.10 ( Ti Seed(ft/min Static Eff.(%) 29 I-.,. „s., i no 0.2 0 --- 0.05 CO Motor _ :._._._, i 0.00 0.0 Motor Mounted Yes 0 2 4 6 8 10 12 Size(hp) 1/4 Volume(CFM)x 100 Voltage/Cycle/Phase 115/60/1 Enclosure ODP L Operating Bhp point Motor RPM 1725 0 Operating point at Total External SP Fan curve Windings I 1 ---•---System curve FLA(Amps) 2.85 Brake horsepower curve Notes: All dimensions shown are in units of in. *NEC FLA-based on tables 430.248 or 430.250 of OfCQ National Electrical Code 2014.Actual motor FLA may vary, OERRT�IUC E Sound Power by Octave Band for sizing thermal overload,consult factory. uTMGt SoundLwA-A weighted sound power level,based on ANSI S1.4 fOUI1D Data 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones dBA-A weighted sound pressure level,based on 11.5 dB D attenuation per Octave band at 5 ft-dBA levels are not Inlet 72 74 75 66 63 62 55 48 71 59 9.8 licensed by AMCA International /MOR p°R Sones-calculated using AMCA 301 at 5 ft ,R mm�r " mo4 ono nmol p'bo ro�ocmnon •o, mnnnnnonm.me. Generated by:kcereghino@johnsonair.com CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj Page 16 of 22 LPrinted Date: 05/01/2019 Building Value in Air. Reece (Ti Mark: Gym Exhaust MJob:odel: G-099-Vgard) G Model: G-099-VG Direct Drive Centrifugal Roof Exhaust Fan Tag: EF-3 Standard Construction Features: -Aluminum housing-Backward inclined composite(sizes 60-95)or aluminum (sizes 97-300)wheel-Aluminum curb cap with prepunched mounting holes- Birdscreen-Ball bearing motors(sizes 85-300 and all Vari Green),sleeve bearing motors(sizes 60-80)-Motor isolated on shock mounts-Corrosion resistant fasteners Selected Options &Accessories: Motor-Vari-Green EC motor Control-Dial for balancing UL/cUL 705 Listed-"Power Ventilators" Switch,NEMA-1,Toggle,Shipped with Unit Junction Box Mounted&Wired Unit Warranty: 1 Yr(Standard) Generated by:kcereghino@johnsonair.com CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj Page 17 of 22 IGREENHECK PrintedJob:Date:Reece 05/01/2019 (Tigard) ® Building Value in Air. Mark: Gym Exhaust Model: G-099-VG Disconnect Switch Enclosure Rating: NEMA-1 Standard Construction Features: Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor corrosion protection design tests. The rod entry test is intended to simulate incidental contact with enclosure equipment. Enclosure is equipped with provision to lockout in the off position with customer supplied lock. Disconnect Switch Configuration Type: Toggle Motor Size: 1/4 hp Voltage: 115 UL Listed: Yes Manufacturer: Pass and Seymour Cycle: 60 Amperage: 15 CSA Approved: Yes Overload Protection: None Phase: 1 Switch Pole(s): 1 Rating: 1/2 hp Junction Box Mtg.: Mounted and Wired RPM: 1725 Exp. Resist. Wiring: None Switch Mounting: Shipped With Unit Electrical Drawing Details 00.28 Wiring (4 HOLES) Schematic O 4.35 1.06 • • O 1.65 O ii 0.72 2.00 1.06 --- - 2.50 Notes:All dimensions shown are in units of in. Generated by:kcereghino@johnsonair.com CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj Page 18 of 22 IftIGREENHECK Printed Date: 05/01/2019 Job: Reece (Tigard) Building Value in Air. Mark: Gym Exhaust Model: G-099-VG Assembly Drawing Type: Direct Drive Centrifugal Roof Exhaust Fan SUGGESTED ROOF OPENING 12.00 14.50 SQ SQ RECOMMENDED EXHAUST DUCT SIZE 024.40 23.70 1.75 35.70 L J � (12.00) 1 ' 19.00 SQ— DUCT DIMENSIONS ARE LARGEST POSSIBLE DUCT TO FIT THROUGH CURB. CONSULT SYSTEM DESIGN ENGINEER FOR RECOMMENDED DUCT SIZE. OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR. Notes:All dimensions shown are in units of in.. Generated by:kcereghino@johnsonair.com CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj Page 19 of 22 LRGREENHECK Printed Date: 05/01/2019 Job: Reece (Tigard) Building Value in Air. Mark: Gym Exhaust Model: G-099-VG Vari-Green Motor & Control Options An EC motor that uses AC input power and internally converts it to DC power. Potentiometer (dial) mounted on the motor enclosure adjusts the speed (RPM) down 80%. Vari-Green motors feature a soft-start and inherent thermal and current protection built into each unit. Inrush current at start up is eliminated and the motor will automatically reduce speed or turn off if overloaded or it becomes too hot. SLACK -----------> INPUT VOLTAGE Motor Configuration �/ HiTE Input Voltage: 115 �! GREEN GROUND Speed Reference: Dial on Motor Permanent Dial: Yes SPEED _,-/I)C CONTROL Control Configuration _.� rte;, Control Type: N/A — _.f + Transformer: None VA►Rt-GREEN Motor DRAWING# I.1.v2 Generated by:kcereghino@johnsonair.com CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj Page 20 of 22 ' IGREENHECK Printed Date: 05/01/2019 Job: Reece (Tigard) Building Value in Air. Mark: Gym Exhaust Model: G-099-VG G-099-VG Min/Max Fan Curve Performance Requested Actual Total External Fan Operating Volume Volume (CFM) (CFM) SP(in.wg) RPM Power(hp) 900 900 0.25 1378 0.12 1 .4 0.28 1725 FRPM 1.2 0.24 i 1 .0 0.20 1378 FRPM' c 0.8 • --r- • I 0.16 22 ` __ - --_ N 0.6 , _ 0 12 ci b _ - 0.4 0.08 m 0.2 0.04 300 - - 0.0 0.00 0 2 4 6 8 10 12 14 Volume (CFM) x 100 L\ Operating Bhp point O Operating point at Total External SP Fan curve - - - -System curve Brake horsepower curve Generated by:kcereghino@johnsonair.com CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj Page 21 of 22 0.GREENHECK Printed Date: 05/01/2019 Job: Reece (Tigard) Building Value in Air. Mark: Gym Exhaust Model: GPI Roof Curb Model: GPI Material: Galvanized Standard Construction Features: - Roof Curb fits between the building roof and the fan mounted directly to the roof support structure -Constructed of either 18 ga galvanized steel or 0.064 in. aluminum - Straight Sided without a cant-2 in. mounting flange-3 lb density insulation - Height -Available from 12 in. to 42 in. as specified in 0.5 in. increments. Notes: -The maximum roof opening dimension should not be greater than the"Actual"top outside dimension minus 2 in.. -The minimum roof opening dimension should be at least 2.5 in. more than the damper dimension or recommended duct size. -The Roof Opening Dimension may or may not be the same as the Structural Opening Dimension. - Damper Tray is optional and must be specified. Tray size is same as damper size. - Security bars are optional and must be specified. Frames and gridwork are all 12 ga steel. Gridwork is welded to the frame and the frame is welded to the curb. 17.50 17.50 12.00 21 .50 21 .50 Notes:All dimensions shown are in units of in. Generated by:kcereghino@johnsonair.com CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj Page 22 of 22 SUBMITTAL Job Title: Reece (Tigard) Elevation: (ft) 108 Date: 5/01/2019 Submitted By: Kyle Cereghino JOHNSON AIR PRODUCTS 2220 SE 9TH AVE PO BOX 15098 PORTLAND, OR 97293 US Phone: (503)234-5071 Fax: (503)233-0451 Email Address: kcereghino@johnsonair.com SUBMITTAL NOTES: ** Louver Submittal ** GREENHECK Building Value in Air. P.O. Box 410 Schofield, WI 54476 (715) 359-6171 FAX (715) 355-2399 www.greenheck.com Generated by:kcereghino@johnsonair.com CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj Page 1 of 4 • 'Mc.�ro�q- oosg3 � s c.1V.). - Printed Date: 05/01/2019 �GREENHECK Job: Reece (Tigard) Building Value in Air. Mark: Intake Louver Model: ESD-403 ESD-403 4 in. Frame APPLICATION & DESIGN ESD-403 is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates a drainable head member and stationary horizontal blades to channel water to the jambs which guides the water through vertical downspouts for escape at the sill. The ESD-403 is an extremely efficient louver with AMCA LICENSED PERFORMANCE DATA enabling designers to select and apply with confidence. PRODUCT DETAILS Frame: 4 in.x 0.081 in.Frame Thickness Internal View Frame Type: Channel Blades: 0.081 in.Fixed Blade Thickness Material: Aluminum • �� Sizing: Nominal • Shape: Rectangular II// Construction: Mechanically Fastened Color to be selected II OPTIONS & ACCESSORIES II/ Finish: Kynar 70%(2 coat),Match Color Chip, (,To Be :4 Selected,IHB) �I/ Bird Screen: 0.75 in.x 0.05 in.,Flat Expanded Aluminum,Internal, .11 Match Louver Finish 0 Warranty: 1 Yr(Standard)Product Warranty 10 Yrs(Standard)Finish Warranty r as 44. ' iso. JAS,,• ,I. Width and Height furnished approximately 0.250 in.under size. SUMMARY (Ii FREE AREA I FREE AREA ID# €TAG QTY. W(in.) i H(in.) ( ) t (�lo} SECT WIDE SECT HIGH SHIP SECT .. J 10-1 I r 1 ] 44.4 1 1 1 178 r Total Louver Qty: 1 Total Weight(Ib): 14 Louver Area(ft2): 4 Total Ship Sect.: 1 **Weight shown is an estimate only based on the default base product configuration-without options or accessories. Larger openings may require field assembly of multiple louver panels to make up the overall opening size.Individual louver panels are designed to withstand windloads up to a maximum of 25 PSF(size and configuration dependent).Design,materials and installation of structural reinforcement required to adequately support large sections or multiple section assemblies within a large opening are not provided by Greenheck.Options and accessories including,but not limited to,screensfilter racks,louver doors,and blankoff panels are not subject to structural analysis unless indicated otherwise by Greenheck.Unless specifically indicatedthe following are NOT included in the quote provided:structural steel,installation hardware(anchors angle clips,continuous angles,shims,fasteners,inserts,backer rod and sealant),field measuring and/or installation,miscellaneous flashing trim or enclosures,blank off panels,mullion covers or mullion hardware, hinged frames or removable subframes,custom bird/insect screen,3-coat,metallic and/or exotic paint finishes,bituminous paints for unlike metals any applicable taxes,stamped and sealed structural calculations seismic calculations or job specific engineered submittal drawings. Generated by:kcereghino@johnsonair.com CAPS 4.29.1458 Y:\KyleCereghino\Reece(Tigard).gfcj Page 2 of 4