Loading...
Specifications Ht.........,000000fikigaioirocorioe0000.0x RECEIVED ALAN DEC 11 2018 • ITY OF TIGARD BUILDING DIVISION DESIGN ASSOCIATES, I N C . OPTION LAN 2376A BY: SOLSTICE CUSTOM HOMES (TRUSS ROOF DESIGN) GRAVITY LOADS BASED ON AFPA NDS-12 FLOOR - 40# LIVE, 10# DEAD ROOF - 25# SNOW 15# DEAD (SHAKE/COMP) 19# DEAD (CONC. TILE) CEILING - 20# LIVE, 10# DEAD DECKS - 60# LIVE, 10# DEAD EXITS/STAIRS - 50# TOTAL LOAD BEAM CALCULATIONS ALAN MASCORD DESIGN ASSOCIATES,INC. 2187 N.W.Reed St. Suite#100 PORTLAND,OR. 97210 page Project:2376a solstice custom homes 11111 Patrick J. Burke Location:D1 -REAR DECK BEAM Alan Mascord Design Multi-Loaded Multi-Span Beam lin 2187 NW Reed St.Ste 100 of [2015 International Building Code(2015 NDS)] Portland,OR 97210 5.5 IN x 11.5 IN x 10.5 FT Pressure Treated #2-Hem-Fir-Wet Use StruCalc Version 10.0.1.6 11/13/2018 11:10:50 AM Section Adequate By:9.1% Controlling Factor: Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.11 IN L/1126 Dead Load 0.02 in Total Load 0.14 IN L/925 Live Load Deflection Criteria: U360 Total Load Deflection Criteria: L/240 REACTIONS A Live Load 1565 lb 1565 lb Dead Load 340 lb 340 lb Total Load 1905 lb 1905 lb Bearing Length 1.28 in 1.28 in BEAM DATA Center Span Length 10.5 ft 10.5 ft B Unbraced Length-Top 0 ft A Unbraced Length-Bottom 10.5 ft Live Load Duration Factor 1.00 Notch Depth 0.00 UNIFORM LOADS Center MATERIAL PROPERTIES Uniform Live Load 298 plf #2-Hem-Fir Uniform Dead Load 53 plf Base Values Adjusted Beam Self Weight 12 plf Bending Stress: Fb= 675 psi Fb'= 540 psi Total Uniform Load 363 plf Cd=9.00 CF=1.00 Ci=0.80 Shear Stress: Fv= 140 psi Fv'= 112 psi Cd=1.00 Ci=0.80 Modulus of Elasticity: E= 1100 ksi E'= 1045 ksi Ci=0.95 Comp.-1-to Grain: Fc- = 405 psi Fc--I-'= 271 psi Cm=0.67 Controlling Moment: 5000 ft-lb 5.25 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Controlling Shear: -1905 lb 10.0 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Comparisons with required sections: Req'd Provided Section Modulus: 111.1 in3 121.23 in3 Area(Shear): 25.51 in2 63.25 in2 Moment of Inertia(deflection): 222.79 in4 697.07 in4 Moment: 5000 ft-lb 5455 ft-lb Shear: -1905 lb 4723 lb Project:2376a solstice custom homes 11111page Location:JC1 -CRAWLSPACE FLR JSTS BELOW PANTRY J HALL BATHiss Patrick J. Burke Floor Joist Alan Mascord Design [2015 International Building Code(2015 NDS)] � P187 NW Ree9 Ste 100 or (2) 1.5 IN x 9.25 IN x 11.0 FT i 16 O.C. Portland, OR 972211 0 #2-Douglas-Fir-Larch-Dry Use Section Adequate By: 34.8% StruCalc Version 10.0.1.6 11/13/2018 11:10:51 AM Controlling Factor:Moment CAUTIONS *Properly connect sheathing to double joists/rafters or fully laminate to transfer diaphragm forces. DEFLECTIONS Center LOADING DIAGRAM Live Load 0.14 IN L/915 Dead Load 0.04 in Total Load 0.18 IN L/732 Live Load Deflection Criteria: L/480 Total Load Deflection Criteria: L/360 REACTIONS A Live Load 544 lb 656 lb Dead Load 136 lb 164 lb Total Load 680 lb 820 lb Bearing Length 0.36 in 0.44 in SUPPORT LOADS A_ Live Load 408 plf 492 plf Dead Load 102 plf 123 plf A 11 ft Total Load 510 plf 615 plf MATERIAL PROPERTIES #2-Douglas-Fir-Larch JOIST DATA Center Base Values Adiusted Span Length 11 ft Bending Stress: Fb= 900 psi Fb'= 1139 psi Unbraced Length-Top 0 ft Cd=1.00 CF=1.10 Cr=1.15 Unbraced Length-Bottom 0 ft Shear Stress: Fv= 180 psi Fv'= 180 psi Floor sheathing applied to top of joists-top of joists fully braced. Cd=1.00 Floor Duration Factor 1.00 Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Comp.1 to Grain: Fc-1= 625 psi Fc-1'= 625 psi JOIST LOADING Uniform Floor Loading Center Controlling Moment: 3011 ft-lb Live Load LL= 40 psf 6.49 Ft from left support of span 2(Center Span) Dead Load DL= 10 psf Created by combining all dead loads and live loads on span(s)2 Total Load TL= 50 psf Controlling Shear: -820 lb TL Adj. For Joist Spacing wT= 66.7 plf At right support of span 2(Center Span) Wall Loading Created by combining all dead loads and live loads on span(s)2 Wall One Live Load(1 to Joists): L1 = 460 plf Comparisons with required sections: Req'd Provided Dead Load(1 to Joists)D1 = 115 plf Section Modulus: 31.74 in3 42.78 in3 Load Location X1 = 6.5 ft Area(Shear): 6.83 in2 27.75 in2 Moment of Inertia(deflection): 103.75 in4 197.86 in4 Moment: 3011 ft-lb 4059 ft-lb Shear: -820 lb 3330 lb page Project:2376a solstice custom homes on Patrick J. Burke f Location: F20-TYP ISOLATED BR'G PAD Alan Mascord Design 2187 NW Reed St.Ste 100 o Footing [2015 International Building Code(2015 NDS)] Portland, OR 97210 Footing Size: 1.667 FT x 1.667 FT x 10.00 IN Section Footing Design Adequate StruCalc Version 10.0.1.6 11/13/2018 11:10:50 AM CAUTIONS *Footing has been designed without reinforcement FOOTING PROPERTIES LOADING DIAGRAM Allowable Soil Bearing Pressure: Qs= 1500 psf Concrete Compressive Strength: F'c= 2500 psi Reinforcing Steel Yield Strength: Fy= 60000 psi Concrete Reinforcement Cover: c= 3 in FOOTING SIZE Width: W= 1.67 ft Length: L= 1.67 ft Depth: Depth= 10 in Effective Depth to Top Layer of Steel: d= 8 in COLUMN AND BASEPLATE SIZE Column Type: Wood Column Width: m= 3.5 in l--3.5in-- Column Depth: n= 3.5 in j FOOTING CALCULATIONS Bearing Calculations: i Ultimate Bearing Pressure: Qu= 1375 psf i Effective Allowable Soil Bearing Pressure:Qe= 1375 psf Required Footing Area: Areq= 2.78 sf 10 in Area Provided: A= 2.78 sf Baseplate Bearing: Bearing Required: Bear= 5347 lb Allowable Bearing: Bear-A= 28634 lb 3.n Beam Shear Calculations(One Way Shear): Beam Shear: Vul = 535 lb ' Allowable Beam Shear: Vol = 5867 lb i 1.6667 ft Punching Shear Calculations(Two Way Shear): Critical Perimeter: Bo= 46 in Punching Shear Vu2= 3579 lb FOOTING LOADING Controlling Allowable Punching Shear: vc2= 26919 lb Live Load: PL= 0 lb Bending Calculations: Dead Load: PD= 3819 lb Factored Moment: Mu= 13367 in-lb Total Load: PT= 3819 lb Nominal Moment Strength: Mn= 29334 in-lb Ultimate Factored Load: Pu= 5347 lb Footing plus soil above footing weight: Wt= 224 lb page , Project:2376a solstice custom homes111111 PatricklaJ. Burke D / Location: F24-TYP ISOLATED BR'G PAD �� Alan Mascord Design Footing 2187 NW Reed St. Ste 100 of [2015 International Building Code(2015 NDS)] _ Portland, OR 97210 Footing Size: 2.0 FT x 2.0 FT x 12.00 IN —' 0 Section Footing Design Adequate StruCalc Version 10.0.1.6 11/13/2018 11:10:50 AM CAUTIONS *Footing has been designed without reinforcement FOOTING PROPERTIES LOADING DIAGRAM Allowable Soil Bearing Pressure: Qs= 1500 psf Concrete Compressive Strength: F'c= 2500 psi Reinforcing Steel Yield Strength: Fy= 60000 psi Concrete Reinforcement Cover: c= 3 in FOOTING SIZE Width: W= 2 ft Length: L= 2 ft Depth: Depth= 12 in Effective Depth to Top Layer of Steel: d= 10 in COLUMN AND BASEPLATE SIZE Column Type: Wood Column Width: m= 3.5 in 1--3sin Column Depth: n = 3.5 in FOOTING CALCULATIONS Bearing Calculations: Ultimate Bearing Pressure: Qu= 1350 psf Effective Allowable Soil Bearing Pressure:Qe= 1350 psf Required Footing Area: Areq = 4 sf 12 in Area Provided: A= 4.00 sf i Baseplate Bearing: Bearing Required: Bear= 7560 lb Allowable Bearing: Bear-A= 28634 lb Beam Shear Calculations(One Way Shear): r !3 in Beam Shear: Vu1 = 630 lb Allowable Beam Shear: Vc1 = 8800 lb Punching Shear Calculations(Two Way Shear): 2 ft Critical Perimeter: Bo= 54 in Punching Shear: Vu2= 5168 lb FOOTING LOADING Controlling Allowable Punching Shear: vc2= 39501 lb Live Load: PL= 0 lb Bending Calculations: Dead Load: PD= 5400 lb Factored Moment: Mu= 22680 in-lb Total Load: PT= 5400 lb Nominal Moment Strength: Mn= 55000 in-lb Ultimate Factored Load: Pu= 7560 lb Footing plus soil above footing weight: Wt= 387 lb page Project:2376a solstice custom homes 11111 Patrick J.Burke Location:F28-TYP ISOLATED BR'G PAD Alan Mascord Design Footing ME 2187 NW Reed St.Ste 100 or [2015 International Building Code(2015 NDS)] .iy, :,..Portland,OR 97210 Footing Size:2.333 FT x 2.333 FT x 14.00 IN Section Footing Design Adequate StruCalc Version 10.0.1.6 11/13/2018 11:10:50 AM CAUTIONS Footing has been designed without reinforcement FOOTING PROPERTIES LOADING DIAGRAM Allowable Soil Bearing Pressure: Qs= 1500 psf Concrete Compressive Strength: F'c= 2500 psi Reinforcing Steel Yield Strength: Fy= 60000 psi Concrete Reinforcement Cover: c= 3 in FOOTING SIZE Width: W= 2.33 ft Length: L= 2.33 ft Depth: Depth= 14 in Effective Depth to Top Layer of Steel: d= 12 in COLUMN AND BASEPLATE SIZE Column Type: Wood Column Width: m= 3.5 in 1-3sin— Column Depth: n= 3.5 in FOOTING CALCULATIONS Bearing Calculations: 1 Ultimate Bearing Pressure: Qu= 1325 psf Effective Allowable Soil Bearing Pressure:Qe= 1325 psf Required Footing Area: Areq= 5.44 sf 14 in Area Provided: A= 5.44 sf Baseplate Bearing: Bearing Required: Bear= 10095 lb Allowable Bearing: Bear-A= 28634 lb T Beam Shear Calculations(One Way Shear): 3 in Beam Shear: Vu1 = 720 lb Allowable Beam Shear: Vcl = 12318 lb —2.333ft Punching Shear Calculations(Two Way Shear): Critical Perimeter: Bo= 62 in Punching Shear: Vu2= 7001 lb FOOTING LOADING Controlling Allowable Punching Shear: vc2= 54424 lb Live Load: PL= 0 lb Bending Calculations: Dead Load: PD= 7211 lb Factored Moment: Mu= 35329 in-lb Total Load: PT= 7211 lb Nominal Moment Strength: Mn= 92387 in-lb Ultimate Factored Load: Pu= 10095 lb Footing plus soil above footing weight: Wt= 614 lb , Project:2376a solstice custom homes page mg Patrick J. Burke Location: F30-TYP ISOLATED BR'G PAD insimir Alan Mascord Design Footing 2187 NW Reed St. Ste 100 of MM., [2015 International Building Code(2015 NDS)] . Portland, OR 97210 Footing Size: 2.5 FT x 2.5 FT x 15.00 IN -- ir >t . Section Footing Design Adequate StruCalc Version 10.0.1.6 11/13/2018 11:10:51 AM CAUTIONS *Footing has been designed without reinforcement FOOTING PROPERTIES LOADING DIAGRAM Allowable Soil Bearing Pressure: Qs= 1500 psf Concrete Compressive Strength: F'c= 2500 psi Reinforcing Steel Yield Strength: Fy= 60000 psi Concrete Reinforcement Cover: c= 3 in FOOTING SIZE Width: W= 2.5 ft Length: L= 2.5 ft Depth: Depth= 15 in Effective Depth to Top Layer of Steel: d= 13 in COLUMN AND BASEPLATE SIZE Column Type: Wood Column Width: m= 3.5 in Column Depth: n= 3.5 in h35in FOOTING CALCULATIONS i I Bearing Calculations: Ultimate Bearing Pressure: Qu= 1312 psf Effective Allowable Soil Bearing Pressure:Qe= 1313 psf Required Footing Area: Areq= 6.25 sf Area Provided: A= 6.25 sf 15 i" Baseplate Bearing: Bearing Required: Bear= 11484 lb Allowable Bearing: Bear-A= 28634 lb E 1 - Beam Shear Calculations(One Way Shear): 3 in Beam Shear: Vu1 = 766 lb Allowable Beam Shear: Vc1 = 14300 lb '— 2.5 ft Punching Shear Calculations(Two Way Shear): Critical Perimeter: Bo= 66 in Punching Shear: Vu2= 8010 lb FOOTING LOADING Controlling Allowable Punching Shear: vc2= 62763 lb Live Load: PL= 0 lb Bending Calculations: Dead Load: PD= 8203 lb Factored Moment: Mu= 43066 in-lb Total Load: PT= 8203 lb Nominal Moment Strength: Mn= 116188 in-lb Ultimate Factored Load: Pu= 11484 lb Footing plus soil above footing weight: Wt= 755 lb page Project:2376a solstice custom homes 1111111 Patrick J. Burke Location:F36-TYP ISOLATED BR'G PAD Alan Mascord Design Footing IBM 2187 NW Reed St.Ste 100 of [2015 International Building Code(2015 NDS)] —411,40-9}.0(..../'t' sgk0(._Portland, OR 97210 Footing Size: 3.0 FT x 3.0 FT x 12.00 IN Reinforcement:#4 Bars @ 9.00 IN.O.C. E/W 1(4)min. StruCalc Version 10.0.1.6 11/13/2018 11:10:51 AM Section Footing Design Adequate FOOTING PROPERTIES ' LOADING DIAGRAM Allowable Soil Bearing Pressure: Qs= 1500 psf Concrete Compressive Strength: F'c= 2500 psi Reinforcing Steel Yield Strength: Fy= 60000 psi Concrete Reinforcement Cover: c= 3 in FOOTING SIZE I-3.5in-? Width: W= 3 ft Length: L= 3 ft Depth: Depth= 12 in Effective Depth to Top Layer of Steel: d= 8.25 in COLUMN AND BASEPLATE SIZE 12 in'r Column Type: Wood . n ci Column Width: m= 3.5 in T Column Depth: n= 3.5 in3in FOOTING CALCULATIONS 3 ft I Bearing Calculations: I-3.5In-4. Ultimate Bearing Pressure: Qu= 1350 psf I _i____ __ Effective Allowable Soil Bearing Pressure: Qe= 1350 psf Required Footing Area: Areq= 9 sf Area Provided: A= 9.00 sf Baseplate Bearing: 12 in Bearing Required: Bear= 17010 lb Allowable Bearing: Bear-A= 33841 lb n n n p T Beam Shear Calculations(One Way Shear): I ' 3 i Beam Shear: Vu1 = 4607 lb .i___ ; _,.._ Allowable Beam Shear: Vc1 = 22275 lb 1 3 f Punching Shear Calculations(Two Way Shear): Critical Perimeter: Bo= 47 in Punching Shear: Vu2= 15198 lb FOOTING LOADING Allowable Punching Shear(ACI 11-35): vc2-a= 87244 lb Live Load: PL= 0 lb Allowable Punching Shear(ACI 11-36): vc2-b= 131175 lb Dead Load: PD= 12150 lb Allowable Punching Shear(ACI 11-37): vc2-c= 58163 lb Total Load: PT= 12150 lb Controlling Allowable Punching Shear: vc2= 58163 lb Ultimate Factored Load: Pu= 17010 lb Bending Calculations: Footing plus soil above footing weight: Wt= 870 lb Factored Moment: Mu= 76545 in-lb Nominal Moment Strength: Mn= 336668 in-lb Reinforcement Calculations: Concrete Compressive Block Depth: a= 0,62 in Steel Required Based on Moment: As(1)= 0.17 in2 Min.Code Req'd Reinf.Shrink./Temp. (ACI-10.5.4):As(2)= 0.78 in2 Controlling Reinforcing Steel: As-reqd= 0.78 in2 Selected Reinforcement: #4's @ 9.0 in. o.c.e/w(4)Min. Reinforcement Area Provided: As= 0.79 in2 Development Length Calculations: Development Length Required: Ld= 15 in Development Length Supplied: Ld-sup= 15 in Note:Plain concrete adequate for bending, therefore adequate development length not required. page , Project:2376a solstice custom homes1111 Patrick J. Burke Location: F42-TYP ISOLATED BR'G PAD Alan Mascord Design Footing 1111112187 NW Reed St. Ste 100 or [2015 International Building Code(2015 NDS)] _Portland,OR 97210 Footing Size: 3.5 FT x 3.5 FT x 12.00 IN Reinforcement:#4 Bars @ 8.00 IN.O.C. EMI/(5)min. StruCalc Version 10.0.1.6 11/13/2018 11:10:51 AM Section Footing Design Adequate FOOTING PROPERTIES LOADING DIAGRAM Allowable Soil Bearing Pressure: Qs= 1500 psf Concrete Compressive Strength: F'c= 2500 psi Reinforcing Steel Yield Strength: Fy= 60000 psi Concrete Reinforcement Cover: c= 3 in FOOTING SIZE Width: W= 3.5 ft Length: L= 3.5 ft 1-3.5 in Depth: Depth= 12 in Effective Depth to Top Layer of Steel: d= 8.25 in COLUMN AND BASEPLATE SIZE Column Type: Wood Column Width: m= 3.5 in 12 in Column Depth: n= 3.5 in c, 0 r, p FOOTING CALCULATIONS _ j j 3 in Bearing Calculations: I 3.5 ft Ultimate Bearing Pressure: Qu= 1350 psf [3.s in Effective Allowable Soil Bearing Pressure: Qe= 1350 psf Required Footing Area: Areq= 12.25 sf Area Provided: A= 12.25 sf Baseplate Bearing: Bearing Required: Bear= 23152 lb 12 in Allowable Bearing: Bear-A= 33841 lb Beam Shear Calculations(One Way Shear): ___:=. -- _ Beam Shear: Vu1 = 7028 lb I Sin Allowable Beam Shear: Vc1 = 25988 lb Punching Shear Calculations(Two Way Shear): 3.5 ft Critical Perimeter: Bo= 47 in Punching Shear: Vu2= 21340 lb FOOTING LOADING Allowable Punching Shear(ACI 11-35): vc2-a= 87244 lb Live Load: PL= 0 lb Allowable Punching Shear(ACI 11-36): vc2-b= 131175 lb Dead Load: PD= 16537 lb Allowable Punching Shear(ACI 11-37): vc2-c= 58163 lb Total Load: PT= 16537 lb Controlling Allowable Punching Shear: vc2= 58163 lb Ultimate Factored Load: Pu= 23152 lb Bending Calculations: Footing plus soil above footing weight: Wt= 1184 lb Factored Moment: Mu= 121547 in-lb Nominal Moment Strength: Mn= 419670 in-lb Reinforcement Calculations: Concrete Compressive Block Depth: a= 0.66 in Steel Required Based on Moment: As(1)= 0.28 in2 Min.Code Req'd Reinf.Shrink./Temp. (ACI-10.5.4):As(2)= 0.91 in2 Controlling Reinforcing Steel: As-reqd= 0.91 in2 Selected Reinforcement: #4's @ 8.0 in. o.c.e/w(5)Min. Reinforcement Area Provided: As= 0.98 in2 Development Length Calculations: Development Length Required: Ld= 15 in Development Length Supplied: Ld-sup= 18 in page Project:2376a solstice custom homes NE Patrick J. Burke / Location:FC1 -TYP MAX BR'G FTG COLUMN UP TO F36 Alan Mascord Design Column in 2187 NW Reed St.Ste 100 or [2015 International Building Code(2015 NDS)] yr 0,}'...Portland.OR 97210 3.5 IN x 3.5 IN x 4.0 FT #2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:51 AM Section Adequate By: 0.0% VERTICAL REACTIONS LOADING DIAGRAM Live Load: Vert-LL-Rxn= 0 lb Dead Load: Vert-DL-Rxn= 14550 lb Total Load: Vert-TL-Rxn= 14550 lb COLUMN DATA B Total Column Length: 4 ft Unbraced Length(X-Axis)Lx: 4 ft Unbraced Length(Y-Axis)Ly: 4 ft Column End Condition-K(e): 1 Axial Load Duration Factor 1.00 COLUMN PROPERTIES #2-Douglas-Fir-Larch Base Values Adiusted Compressive Stress: Fc= 1350 psi Fc'= 1188 psi Cd=0.90 Cf=1.15 Cp=0 85 Bending Stress(X-X Axis): Fbx= 900 psi Fbx'= 1215 psi Cd=0.90 CF=1.50 4 ft Bending Stress(Y-Y Axis): Fby= 900 psi Fby'= 1215 psi Cd=0.90 CF=1.50 Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi €' Column Section(X-X Axis): dx= 3.5 in Column Section(Y-Y Axis): dy= 3.5 in Area: A= 12.25 in2 r Section Modulus(X-X Axis): Sx= 7.15 in3 Section Modulus(Y-Y Axis): Sy= 7.15 in3 Slenderness Ratio: Lex/dx= 13.71 rr Ley/dy= 13.71 A Column Calculations(Controlling Case Only): AXIAL LOADING Controlling Load Case:Axial Dead Load Only(D) Actual Compressive Stress: Fc= 1188 psi Live Load: PL= 0 lb Allowable Compressive Stress: Fe= 1188 psi Dead Load: PD= 14539 lb Eccentricity Moment(X-X Axis): Mx-ex= 0 ft-lb Column Self Weight: CSW= 11 lb Eccentricity Moment(Y-Y Axis): My-ey= 0 ft-lb Total Axial Load: PT= 14550 lb Moment Due to Lateral Loads(X-X Axis): Mx= 0 ft-lb Moment Due to Lateral Loads(Y-Y Axis): My= 0 ft-lb Bending Stress Lateral Loads Only(X-X Axis):Fbx= 0 psi Allowable Bending Stress(X-X Axis): Fbx'= 1215 psi Bending Stress Lateral Loads Only(Y-Y Axis):Fby= 0 psi Allowable Bending Stress(Y-Y Axis): Fby'= 1215 psi Combined Stress Factor: CSF= 1 , Project:2376a solstice custom homes page 11111 Patrick J. Burke Location: FC2-TYP MAX BR'G FTG COLUMN @ F42 Alan Mascord Design Column IIIIII 2187 NW Reed St.Ste 100 of [2015 International Building Code(2015 NDS)] 4 ,,6, -Portland, OR 97210 5.5 IN x 5.5 IN x 4.0 FT - #2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:51 AM Section Adequate By: 0.0% VERTICAL REACTIONS LOADING DIAGRAM Live Load: Vert-LL-Rxn= 0 lb Dead Load: Vert-DL-Rxn= 18547 lb Total Load: Vert-TL-Rxn= 18547 lb COLUMN DATA Total Column Length: 4 ft B Unbraced Length(X-Axis)Lx: 4 ft Unbraced Length(Y-Axis)Ly: 4 ft Column End Condition-K(e): 1 Axial Load Duration Factor 1.00 COLUMN PROPERTIES ', -z #2-Douglas-Fir-Larch Base Values Adjusted j Compressive Stress: Fc= 700 psi Fc'= 613 psi Cd=0.90 Cp=0.97 Bending Stress(X-X Axis): Fbx= 750 psi Fbx'= 675 psi . ,.;,j Cd=0.90 CF=1.00 4 ft ; Bending Stress(Y-Y Axis): Fby= 750 psi Fby'= 675 psi Cd=0.90 CF=1.00 Modulus of Elasticity: E= 1300 ksi E'= 1300 ksi A 4- Column Section(X-X Axis): dx= 5.5 in Column Section(Y-Y Axis): dy= 5.5 in Area: A= 30.25 in2 Section Modulus(X-X Axis): Sx= 27.73 in3 Section Modulus(Y-Y Axis): Sy= 27.73 in3 Slenderness Ratio: Lex/dx= 8.73 Ley/dy= 8.73 A Column Calculations(Controlling Case Only): Controlling Load Case:Axial Dead Load Only(D) AXIAL LOADING Actual Compressive Stress: Fc= 613 psi Live Load: PL= 0 lb Allowable Compressive Stress: Fc'= 613 psi Dead Load: PD= 18521 lb Eccentricity Moment(X-X Axis): Mx-ex= 0 ft-lb Column Self Weight: CSW= 26 lb Eccentricity Moment(Y-Y Axis): My-ey= 0 ft-lb Total Axial Load: PT= 18547 lb Moment Due to Lateral Loads(X-X Axis): Mx= 0 ft-lb Moment Due to Lateral Loads(Y-Y Axis): My= 0 ft-lb Bending Stress Lateral Loads Only(X-X Axis):Fbx= 0 psi Allowable Bending Stress(X-X Axis): Fbx'= 675 psi Bending Stress Lateral Loads Only(Y-Y Axis):Fby= 0 psi Allowable Bending Stress(Y-Y Axis): Fby'= 675 psi Combined Stress Factor: CSF= 1 page Project:2376a solstice custom homes IIIII Patrick J. Burke Location:J1 -FLR JSTS O/FRONT 16/0 BAY GAR IKE Alan Mascord Design Floor Joist 2187 NW Reed St.Ste 100 or [2015 International Building Code(2015 NDS)] _„. '.:Portland, OR 97210 1.5INx11.251Nx11.OFT @16O.C. #2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:51 AM Section Adequate By: 80.0% Controlling Factor: Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.08 IN L/1662 Dead Load 0.04 in Total Load 0.12 IN L/1125 Live Load Deflection Criteria: L/480 Total Load Deflection Criteria:L/360 REACTIONS A B Live Load 458 lb 330 lb Dead Load 282 lb 120 lb Total Load 740 lb 450 lb Bearing Length 0.79 in 0.48 in SUPPORT LOADS A B Live Load 344 plf 248 plf --'_.. Dead Load 212 plf 90 plf A 11 n B Total Load 555 plf 338 plf MATERIAL PROPERTIES #2-Douglas-Fir-Larch JOIST DATA Center Base Values Adjusted Span Length 11 ft Bending Stress: Fb= 900 psi Fb'= 1035 psi Unbraced Length-Top 0 ft Cd=1.00 CF=1.00 Cr=1.15 Unbraced Length-Bottom 0 ft Shear Stress: Fv= 180 psi Fv'= 180 psi Floor sheathing applied to top of joists-top of joists fully braced. Cd=1.00 Floor Duration Factor 1.00 Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi JOIST LOADING Comp.-I-to Grain: Fc--1-= 625 psi Fc--1-'= 625 psi Uniform Floor Loading Center Live Load LL= 40 psf Controlling Moment: 1516 ft-lb Dead Load DL= 10 psf 4.29 Ft from left support of span 2(Center Span) Total Load TL= 50 psf Created by combining all dead loads and live loads on span(s)2 TL Adj. For Joist Spacing wT= 66.7 plf Controlling Shear: 740 lb Wall Loading At left support of span 2(Center Span) Wall One Created by combining all dead loads and live loads on span(s)2 Live Load (1 to Joists): L1 = 151 plf Dead Load(1 to Joists)D1 = 191 plf Comparisons with required sections: Req'd Provided Load Location X1 = 2 ft Section Modulus: 17.58 in3 31.64 in3 Area(Shear): 6.16 in2 16.88 in2 Moment of Inertia(deflection): 56.98 in4 177.98 in4 Moment: 1516 ft-lb 2729 ft-lb Shear: 740 lb 2025 lb , Project:2376a solstice custom homes in page Patrick J. Burke Location:M1 -GAR BM SHORT SPAN FROM FOYER RECESS �� Alan Mascord Design Multi-Loaded Multi-Span Beam 2187 NW Reed St. Ste 100 of [2015 International Building Code(2015 NDS)] e o .Portland, OR 97210 (2)1.51Nx11.25INx3.0FT #2-Douglas-Fir-Larch Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:51 AM Section Adequate By: 524.5% Controlling Factor: Shear CAUTIONS *Laminations are to be fully connected to provide uniform transfer of loads to all members DEFLECTIONS Center LOADING DIAGRAM Live Load 0.00 IN L/MAX Dead Load 0.00 in Total Load 0.00 IN L/MAX Live Load Deflection Criteria: U360 Total Load Deflection Criteria:0240 REACTIONS A Live Load 339 lb 339 lb Dead Load 309 lb 309 lb Total Load 648 lb 648 lb TRI Bearing Length 0.35 in 0.35 in BEAM DATA Centerso, Span Length 3 ft - Unbraced Length-Top O ft A 3 ft Unbraced Length-Bottom 3 ft Live Load Duration Factor 1.00 Notch Depth 0.00 UNIFORM LOADS Center MATERIAL PROPERTIES Uniform Live Load 100 plf #2-Douglas-Fir-Larch Uniform Dead Load 115 plf Base Values Adjusted Beam Self Weight 7 plf Bending Stress: Fb= 900 psi Fb'= 900 psi Total Uniform Load 222 plf Cd=1.00 CF=1.00 TRAPEZOIDAL LOADS-CENTER SPAN Shear Stress: Fv= 180 psi Fv'= 180 psi Load Number One Cd=1.00 Left Live Load 126 plf Modulus of Elasticity: E= 1 1600 ksi E'=1 1600 ksi Left Dead Load 84 plf Comp. to Grain: Fc- _ 625 psi Fc- = 625 psi Right Live Load 126 plf Right Dead Load 84 plf Controlling Moment: 486 ft-lb Load Start 0 ft 1.5 Ft from left support of span 2(Center Span) Load End 3 ft Created by combining all dead loads and live loads on span(s)2 Load Length 3 ft Controlling Shear: -648 lb At right support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Comparisons with required sections: Req'd Provided Section Modulus: 6.48 in3 63.28 in3 Area(Shear): 5.4 in2 33.75 in2 Moment of Inertia(deflection): 3.28 in4 355.96 in4 Moment: 486 ft-lb 4746 ft-lb Shear: -648 lb 4050 lb page Project:2376a solstice custom homes Ell Patrick J. Burke Location:M2-GAR BM-FRONT 1ST BAY mg Alan Mascord Design Multi-Loaded Multi-Span Beam Km2187 NW Reed St.Ste 100 of [2015 International Building Code(2015 NDS)] __,.tie e:_Portland,OR 97210 5.5 IN x 11.51N x 11.0 FT #2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:52 AM Section Adequate By:26.9% Controlling Factor: Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.09 IN L/1451 Dead Load 0.07 in Total Load 0.16 IN L/834 Live Load Deflection Criteria: U360 Total Load Deflection Criteria: L/240 1 REACTIONS A B 2 Live Load 875 lb 1544 lb Dead Load 627 lb 1191 lb Total Load 1502 lb 2735 lbTR1 TR2 Bearing Length 0.44 in 0.80 in w BEAM DATA Center Span Length 11 ft 1111 Unbraced Length-Top O ft A — 11 n B Unbraced Length-Bottom 11 ft Live Load Duration Factor 1.00 Notch Depth 0.00 UNIFORM LOADS Center MATERIAL PROPERTIES Uniform Live Load 40 plf #2-Douglas-Fir-Larch Uniform Dead Load 10 plf Base Values Adiusted Beam Self Weight 14 plf Bending Stress: Fb= 875 psi Fb'= 875 psi Total Uniform Load 64 plf Cd=1.00 CF=1.00 POINT LOADS-CENTER SPAN Shear Stress: Fv= 170 psi Fv'= 170 psi Load Number One Two* Cd=1.00 Live Load 602 lb 339 lb Modulus of Elasticity: E= 1300 ksi E'= 1300 ksi Dead Load 402 lb 309 lb Comp.-I-to Grain: Fc-1= 625 psi Fc--I-'= 625 psi Location 8 ft 6 ft *Load obtained from Load Tracker. See Summary Report for details. Controlling Moment: 6968 ft-lb 6.05 Ft from left support of span 2(Center Span) TRAPEZOIDAL LOADS-CENTER SPAN Created by combining all dead loads and live loads on span(s)2 Load Number One Two Controlling Shear: -2735 lb Left Live Load 170 plf 50 plf At right support of span 2(Center Span) Left Dead Load 164 plf 34 plf Created by combining all dead loads and live loads on span(s)2 Right Live Load 170 plf 126 plf Right Dead Load 164 plf 84 plf Comparisons with required sections: Req'd Provided Load Start 8 ft 2 ft Section Modulus: 95.56 in3 121.23 in3 Load End 11 ft 8 ft Area(Shear): 24.13 in2 63.25 in2 Load Length 3 ft 6 ft Moment of Inertia(deflection): 200.48 in4 697.07 in4 Moment: 6968 ft-lb 8840 ft-lb Shear: -2735 lb 7168 lb , Project:2376a solstice custom homes page 11111 Patrick J. Burke Location: M3-GAR BM-FRONT 2ND BAY Alan Mascord Design Multi-Loaded Multi-Span Beam 11111 2187 NW Reed St.Ste 100 of [2015 International Building Code(2015 NDS)] Portland, OR 97210 3.125 IN x 10.5 IN x 11.0 FT — : 24F-V4-Visually Graded Western Species-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:52 AM Section Adequate By:26.4% Controlling Factor:Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.19 IN L/686 Dead Load 0.13 in Total Load 0.32 IN L/407 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria: L/240 REACTIONS A B 2 Live Load 1089 lb 2190 lb Dead Load 712 lb 1641 lb 1 Total Load 1801 lb 3831 lb TRI Bearing Length 0.89 in 1.89 in TR2 BEAM DATA Center w Span Length 11 ft Unbraced Length-Top 0 ft A 11 ft B Unbraced Length-Bottom 11 ft Live Load Duration Factor 1.00 Camber Adj. Factor 1.5 Camber Required 0.2 UNIFORM LOADS Center Notch Depth 0.00 Uniform Live Load 40 plf Uniform Dead Load 10 plf MATERIAL PROPERTIES Beam Self Weight 7 plf 24F-V4-Visually Graded Western Species Total Uniform Load 57 plf Base Values Adjusted POINT LOADS-CENTER SPAN Bending Stress: Fb= 2400 psi Controlled by: Fb_cmpr= 1850 psi Fb'= 2400 psi Load Number One Two Cd=1.00 Live Load 111 Ib 1513 Ib Shear Stress: Fv= 265 psi Fv'= 265 psi Dead Load 74 lb 1008 lb Cd=1.00 Location 1.5 ft 8 ft Modulus of Elasticity: E= 1800 ksi E'= 1800 ksi TRAPEZOIDAL LOADS-CENTER SPAN Comp.L to Grain: Fc-1= 650 psi Fc-1'= 650 psi Load Number One Two Left Live Load 229 plf 50 plf Controlling Moment: 9089 ft-lb Left Dead Load 243 plf 34 plf 7.92 Ft from left support of span 2(Center Span) Right Live Load 229 plf 126 plf Created by combining all dead loads and live loads on span(s)2 Right Dead Load 243 plf 84 plf Controlling Shear: -3831 lb Load Start 8 ft 2 ft At right support of span 2(Center Span) Load End 11 ft 8 ft Created by combining all dead loads and live loads on span(s)2 Load Length 3 ft 6 ft Comparisons with required sections: Req'd Provided Section Modulus: 45.44 in3 57.42 in3 Area(Shear): 21.68 in2 32.81 in2 Moment of Inertia(deflection): 177.79 in4 301.46 in4 Moment: 9089 ft-lb 11484 ft-lb Shear: -3831 lb 5797 lb page Project:2376a solstice custom homes 11111 Patrick J. Burke Location: M4- 16/0 GAR DR HDR Alan Mascord Design Multi-Loaded Multi-Span Beam ril 2187 NW Reed St.Ste 100 of [2015 International Building Code(2015 NDS)] ea[,..Portland,OR 97210 5.125 IN x 13.5 IN x 16.0 FT 24F-V4-Visually Graded Western Species-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:52 AM Section Adequate By:4.2% Controlling Factor:Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.44 IN L/432 Dead Load 0.29 in Total Load 0.74 IN L/261 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria:L/240 REACTIONS A B Live Load 4552 lb 4657 lb 1 2 Dead Load 3037 lb 3059 lb Total Load 7589 lb 7716 lb Bearing Length 2.28 in 2.32 in TR2 BEAM DATA Center Span Length 16 ft -- — _ -- — Unbraced Length-Top 0 ft A 16 ft B Unbraced Length-Bottom 16 ft Live Load Duration Factor 1.00 Camber Adj. Factor 1 UNIFORM LOADS Center Camber Required 0.29 Uniform Live Load 0 plf Notch Depth 0.00 Uniform Dead Load 0 plf MATERIAL PROPERTIES Beam Self Weight 15 plf 24F-V4-Visually Graded Western Species Total Uniform Load 15 plf Base Values Adjusted POINT LOADS-CENTER SPAN Bending Stress: Fb= 2400 psi Controlled by: Load Number One* Two* Fb_cmpr= 1850 psi Fb'= 2400 psi Live Load 875 lb 1089 lb Cd=100 Dead Load 627 lb 712 lb Shear Stress: Fv= 265 psi Fv'= 265 psi Location 1.5 ft 14.5 ft Cd=1.00 *Load obtained from Load Tracker. See Summary Report for details. Modulus of Elasticity: E= 1800 ksi E'= 1800 ksi Comp..1 to Grain: Fc-1= 650 psi Fc-1'= 650 psi TRAPEZOIDAL LOADS-CENTER SPAN Load Number One Two* Three " Controlling Moment: 29883 ft-lb Left Live Load 126 plf 534 plf 76 plf 8.0 Ft from left support of span 2(Center Span) Left Dead Load 84 plf 332 plf 50 plf Created by combining all dead loads and live loads on span(s)2 Right Live Load 126 plf 534 plf 76 plf Controlling Shear: -7717 lb Right Dead Load 84 plf 332 plf 50 plf At right support of span 2(Center Span) Load Start 0 ft 1.5 ft 14.5 ft Created by combining all dead loads and live loads on span(s)2 Load End 1.5 ft 14.5 ft 16 ft Load Length 1.5 ft 13 ft 1.5 ft Comparisons with required sections: Read Provided *Load obtained from Load Tracker. See Summary Report for details. Section Modulus: 149.41 in3 155.67 in3 Area(Shear): 43.68 in2 69.19 in2 Moment of Inertia(deflection): 965.98 in4 1050.79 in4 Moment: 29883 ft-lb 31134 ft-lb Shear: -7717 lb 12223 lb Page Project:2376a solstice custom homes Patrick J. Burke Location: M5-8/0 GAR DR HDR �� Alan Mascord Design Multi-Loaded Multi-Span Beam 2187 NW Reed St.Ste 100 of [2015 International Building Code(2015 NDS)] , ' j. Portland,OR 97210 3.5INx5.5INx8.0FT #2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:52 AM Section Adequate By: 0.4% Controlling Factor: Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.15 IN L/642 Dead Load 0.10 in Total Load 0.25 IN L/378 Live Load Deflection Criteria: U360 Total Load Deflection Criteria: L/240 REACTIONS A Live Load 504 lb 504 lb Dead Load 353 lb 353 lb Total Load 857 lb 857 lb Bearing Length 0.39 in 0.39 in BEAM DATA Center Span Length 8 ft . ----- - Unbraced Length-Top 0 ft - s ft -- B Unbraced Length-Bottom 8 ft Live Load Duration Factor 1.00 Notch Depth 0.00 UNIFORM LOADS Center MATERIAL PROPERTIES Uniform Live Load 126 plf #2-Douglas-Fir-Larch Uniform Dead Load 84 plf Base Values Adjusted Beam Self Weight 4 plf Bending Stress: Fb= 900 psi Fb'= 1170 psi Total Uniform Load 214 plf Cd=1.00 CF=1.30 Shear Stress: Fv= 180 psi Fv'= 180 psi Cd=1.00 Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Comp.-L to Grain: Fc-L= 625 psi Fc--- = 625 psi Controlling Moment: 1713 ft-lb 4.0 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Controlling Shear: -857 lb At right support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Comparisons with required sections: Reo'd Provided Section Modulus: 17.57 in3 17.65 in3 Area(Shear): 7.14 in2 19.25 in2 Moment of Inertia(deflection): 30.84 in4 48.53 in4 Moment: 1713 ft-lb 1720 ft-lb Shear: -857 lb 2310 lb page Project:2376a solstice custom homes 1111 Patrick J.Burke / Location:M6-GAR BM-REAR 3RD BAYmin Alan Mascord Design Multi-Loaded Multi-Span Beam 2187 NW Reed St.Ste 100 or [2015 International Building Code(2015 NDS)] ' }. i9. .:Portland,OR 97210 5.125 INx9.0INx9.0FT 24F-V4-Visually Graded Western Species-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:52 AM Section Adequate By:22.9% Controlling Factor: Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.16 IN L/693 Dead Load 0.11 in Total Load 0.27 IN L/402 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria:L/240 1 REACTIONS A B Live Load 3119 lb 1857 lb Dead Load 2228 lb 1386 lb Total Load 5347 lb 3243 lb TRI Bearing Length 1.61 in 0.97 in w BEAM DATA CenterifilEORT;::tt .Iitfaszommatssittli.. Span Length 9 ft Unbraced Length-Top 0 ft A _.9 ft -- —__ B Unbraced Length-Bottom 9 ft Live Load Duration Factor 1.00 Camber Adj. Factor 1 UNIFORM LOADS Center Camber Required 0.11 Uniform Live Load 160 plf Notch Depth 0.00 Uniform Dead Load 130 plf MATERIAL PROPERTIES Beam Self Weight 10 plf 24F-V4-Visually Graded Western Species Total Uniform Load 300 plf Base Values Adiusted POINT LOADS-CENTER SPAN Bending Stress: Fb= 2400 psi Controlled by: Load Number One Fb_cmpr= 1850 psi Fb'= 2400 psi Live Load 1568 lb Cd=1.00 Dead Load 1046 lb Shear Stress: Fv= 265 psi Fv'= 265 psi Location 3 ft Cd=1.00 Modulus of Elasticity: E= 1800 ksi E'= 1800 ksi TRAPEZOIDAL LOADS-CENTER SPAN Comp.1 to Grain: Fc-1= 650 psi Fc-1'= 650 psi Load Number One Two Left Live Load 454 plf 126 plf Controlling Moment: 11260 ft-lb Left Dead Load 302 plf 84 plf 3.06 Ft from left support of span 2(Center Span) Right Live Load 454 plf 76 plf Created by combining all dead loads and live loads on span(s)2 Right Dead Load 302 plf 50 plf Controlling Shear: 5347 lb Load Start 0 ft 3 ft At left support of span 2(Center Span) Load End 3 ft 9 ft Created by combining all dead loads and live loads on span(s)2 Load Length 3 ft 6 ft Comparisons with required sections: Req'd Provided Section Modulus: 56.3 in3 69.19 in3 Area(Shear): 30.26 in2 46.13 in2 Moment of Inertia(deflection): 185.75 in4 311.34 in4 Moment: 11260 ft-lb 13838 ft-lb Shear: 5347 lb 8149 lb Project:2376a solstice custom homes in page Patrick J. Burke Location:M7-GAR BM-REAR 2ND BAY-SHORT SPAN Alan Mascord Design Multi-Loaded Multi-Span Beam IIIII 2187 NW Reed St.Ste 100 of [2015 International Building Code(2015 NDS)] Portland, OR 97210 7.0INx9.5INx3.0FT - 7 sp - 2.0E Parallam-iLevel Trus Joist StruCalc Version 10.0.1.6 11/13/2018 11:10:52 AM Section Adequate By: 1.8% Controlling Factor:Shear DEFLECTIONS Center LOADING DIAGRAM Live Load 0.00 IN L/7355 Dead Load 0.00 in Total Load 0.01 IN L/4371 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria:L/240 REACTIONS A_ Live Load 7539 lb 2245 lb Dead Load 5092 lb 1562 lb Total Load 12631 lb 3807 lb TR1 Bearing Length 2.41 in 0.73 in BEAM DATA Center " Span Length 3 ft -•• Unbraced Length-Top O ft A 3 ft B Unbraced Length-Bottom 3 ft Live Load Duration Factor 1.00 Notch Depth 0.00 UNIFORM LOADS Center MATERIAL PROPERTIES Uniform Live Load 160 plf 2.0E Parallam-iLevel Trus Joist Uniform Dead Load 130 plf Base Values Adjusted Beam Self Weight 21 plf Bending Stress: Fb= 2900 psi Fb'= 2976 psi Total Uniform Load 311 plf Cd=1.00 CF=1.03 Shear Stress: Fv= 290 psi Fv'= 290 psi POINT LOADS-CENTER SPAN Cd=1.00 Load Number One Modulus of Elasticity: E= 2000 ksi E'= 2000 ksi Live Load 7942 lb Comp.-I-to Grain: Fc--1--= 750 psi Fc- L'= 750 psi Dead Load 5295 lb Location 0.5 ft Controlling Moment: 6171 ft-lb TRAPEZOIDAL LOADS-CENTER SPAN 0.51 Ft from left support of span 2(Center Span) Load Number One Created by combining all dead loads and live loads on span(s)2 Left Live Load 454 plf Controlling Shear: 12631 lb Left Dead Load 302 plf At left support of span 2(Center Span) Right Live Load 454 plf Created by combining all dead loads and live loads on span(s)2 Right Dead Load 302 plf Load Start 0 ft Comparisons with required sections: Req'd Provided Load End 3 ft Section Modulus: 24.88 in3 105.29 in3 Load Length 3 ft Area(Shear): 65.33 in2 66.5 in2 Moment of Inertia(deflection): 27.46 in4 500.14 in4 Moment: 6171 ft-lb 26115 ft-lb Shear: 12631 lb 12857 lb page Project:2376a solstice custom homes IIIIE Patrick J. Burke Location:M8-GAR BM-REAR 2ND BAY on Alan Mascord Design Multi-Loaded Multi-Span Beam 11111. 2187 NW Reed St.Ste 100 of [2015 International Building Code(2015 NDS)] Y . .4ie !.:Portland,OR 97210 7.OINx11.25INx10.OFT 2.0E Parallam-iLevel Trus Joist StruCalc Version 10.0.1.6 11/13/2018 11:10:52 AM Section Adequate By: 12.2% Controlling Factor:Shear DEFLECTIONS Center LOADING DIAGRAM Live Load 0.12 IN L/1043 Dead Load 0.08 in Total Load 0.19 IN L/617 Live Load Deflection Criteria: U360 Total Load Deflection Criteria: L/240 REACTIONS A B 2 Live Load 8033 lb 1940 lb 1 Dead Load 5536 lb 1361 lb Total Load 13569 lb 3301 lb TRI Bearing Length 2.58 in 0.63 in w BEAM DATA Center 1.'"iiciFiihki. ."A:. ::;tt::;Yi :::.: 5*..:— Span Length 10 ft Unbraced Length-Top 0 ft A —ion B Unbraced Length-Bottom 10 ft Live Load Duration Factor 1.00 Notch Depth 0.00 UNIFORM LOADS Center MATERIAL PROPERTIES Uniform Live Load 40 plf 2.0E Parallam-iLevel Trus Joist Uniform Dead Load 10 plf Base Values Adjusted Beam Self Weight 25 plf Bending Stress: Fb= 2900 psi Fb'= 2921 psi Total Uniform Load 75 plf Cd=1.00 CF=1.01 POINT LOADS-CENTER SPAN Shear Stress: Fv= 290 psi Fv'= 290 psi Load Number One Two* Cd=1.00 Live Load 1467 lb 7539 lb Modulus of Elasticity: E= 2000 ksi E'= 2000 ksi Dead Load 978 lb 5092 lb Comp.- to Grain: Fc-1= 750 psi Fc--1-'= 750 psi Location 1 ft 2 ft *Load obtained from Load Tracker.See Summary Report for details. Controlling Moment: 24020 ft-lb 2.0 Ft from left support of span 2(Center Span) TRAPEZOIDAL LOADS-CENTER SPAN Created by combining all dead loads and live loads on span(s)2 Load Number One Controlling Shear: 13569 lb Left Live Load 567 plf At left support of span 2(Center Span) Left Dead Load 481 plf Created by combining all dead loads and live loads on span(s)2 Right Live Load 567 plf Right Dead Load 481 plf Comparisons with required sections: Red Provided Load Start 1 ft Section Modulus: 98.68 in3 147.66 in3 Load End 2 ft Area(Shear): 70.19 in2 78.75 in2 Load Length 1 ft Moment of Inertia(deflection): 323.27 in4 830.57 in4 Moment: 24020 ft-lb 35940 ft-lb Shear: 13569 lb 15225 lb Project:2376a solstice custom homes page PatrickIIIII J. Burke Location:M9-MAIN GAR BM-16/0 BAY 1111112187 Mascord Design Multi-Loaded Multi-Span Beam 2187 NW Reed St.Ste 100 or [2015 International Building Code(2015 NDS)] Portland,OR 97210 5.125 IN x 22.5 IN x 19.0 FT ___,.140402..„01.,,t,.. 24F-V4-Visually Graded Western Species-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:53 AM Section Adequate By:6.2% Controlling Factor: Shear DEFLECTIONS Center LOADING DIAGRAM Live Load 0.29 IN L/790 Dead Load 0.16 in Total Load 0.45 IN L/510 Live Load Deflection Criteria: U360 Total Load Deflection Criteria:L/240 REACTIONS A B 2 Live Load 6759 lb 11806 lb Dead Load 3550 lb 7370 lb 1 Total Load 10309 lb 19176 lb TRS Bearing Length 3.09 in 5.76 in TR1 BEAM DATA Center _ Span Length 19 ft Unbraced Length-Top 0 ft l- 19ft B Unbraced Length-Bottom 19 ft Live Load Duration Factor 1.00 Camber Adj. Factor 1 UNIFORM LOADS Center Camber Required 0.16 Uniform Live Load 0 plf Notch Depth 0.00 Uniform Dead Load 0 plf MATERIAL PROPERTIES Beam Self Weight 25 plf 24F-V4-Visually Graded Western Species Total Uniform Load 25 plf Base Values Adjusted POINT LOADS-CENTER SPAN Bending Stress: Fb= 2400 psi Controlled by: Load Number One* Two* Three Fb_cmpr= 1850 psi Fb'= 2276 psi Live Load 1544 lb 2190 lb 8033 lb Cd=1.00 Cv=0.95 Dead Load 1191 lb 1641 lb 5536 lb Shear Stress: Fv= 265 psi Fv'= 265 psi Location 2.5 ft 16 ft 16 ft Cd=1.00 Modulus of Elasticity: E= 1800 ksi E'= 1800 ksi *Load obtained from Load Tracker.See Summary Report for details. Comp.-L to Grain: Fc-1= 650 psi Fc-1'= 650 psi TRAPEZOIDAL LOADS-CENTER SPAN Load Number One Two Three * Controlling Moment: 59774 ft-lb Left Live Load 200 plf 100 plf 248 plf 13.3 Ft from left support of span 2(Center Span) Left Dead Load 50 plf 25 plf 90 plf Created by combining all dead loads and live loads on span(s)2 Right Live Load 200 plf 100 plf 248 plf Controlling Shear: -19176 lb Right Dead Load 50 plf 25 plf 90 plf At right support of span 2(Center Span) Load Start 0 ft 0 ft 2.5 ft Created by combining all dead loads and live loads on span(s)2 Load End 16 ft 2.5 ft 16 ft Load Length 16 ft 2.5 ft 13.5 ft Comparisons with required sections: Req'd Provided *Load obtained from Load Tracker, See Summary Report for details. Section Modulus: 315.09 in3 432.42 in3 Area(Shear): 108.54 in2 115.31 in2 Moment of Inertia(deflection): 2287.79 in4 4864.75 in4 Moment: 59774 ft-lb 82032 ft-lb Shear: -19176 lb 20372 lb page Project:2376a solstice custom homes En Patrick J. Burke Location: M10-GAR BM BTWN 16/0&8/0 BAYS Alan Mascord Design Multi-Loaded Multi-Span Beam 111111 2187 NW Reed St.Ste 100 of [2015 International Building Code(2015 NDS)] ____,.14:40,1614Z,._Portland.OR 97210 6.75 IN x 25.5 IN x 19.0 FT 24F-V4-Visually Graded Western Species-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:51 AM Section Adequate By:4.7% Controlling Factor:Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.25 IN L/906 Dead Load 0.17 in Total Load 0.42 IN L/542 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria: L/240 REACTIONS A B 1 Live Load 8540 lb 8950 lb Dead Load 5846 lb 6103 lb 2 Total Load 14386 lb 15053 lb Bearing Length 3.28 in 3.43 in TR1 BEAM DATA Center Span Length 19 ft - B Unbraced Length-Top 0 ft A —19ft Unbraced Length-Bottom 19 ft Live Load Duration Factor 1.00 Camber Adj. Factor 1 UNIFORM LOADS Center Camber Required 0.17 Uniform Live Load 0 plf Notch Depth 0.00 Uniform Dead Load 0 plf MATERIAL PROPERTIES Beam Self Weight 37 plf 24F-V4-Visually Graded Western Species Total Uniform Load 37 plf Base Values Adiusted POINT LOADS-CENTER SPAN Bending Stress: Fb= 2400 psi Controlled by: Load Number One* Two* Three " Fbcmpr= 1850 psi Fb'= 2187 psi Live Load 11806 lb 3119 Ib 2245 lb Cd_=1.00 Cv=0.91 Dead Load 7370 lb 2228 lb 1562 lb Shear Stress: Fv= 265 psi Fv'= 265 psi Location 9 ft 11 ft 11 ft Cd=1.00 *Load obtained from Load Tracker.See Summary Report for details. Modulus of Elasticity: E= 1800 ksi E= 1800 ksi Comp.1 to Grain: Fc--L= 650 psi Fc--L'= 650 psi TRAPEZOIDAL LOADS-CENTER SPAN Load Number One Controlling Moment: 127344 ft-lb Left Live Load 40 plf 9.12 Ft from left support of span 2(Center Span) Left Dead Load 10 plf Created by combining all dead loads and live loads on span(s)2 Right Live Load 40 plf Controlling Shear: -15053 lb Right Dead Load 10 plf At right support of span 2(Center Span) Load Start 11 ft Created by combining all dead loads and live loads on span(s)2 Load End 19 ft Load Length 8 ft Comparisons with required sections: Req'd Provided Section Modulus: 698.71 in3 731.53 in3 Area(Shear): 85.21 in2 172.13 in2 Moment of Inertia(deflection): 4128.05 in4 9327.02 in4 Moment: 127344 ft-lb 133325 ft-lb Shear: -15053 lb 30409 lb page Project:2376a solstice custom homes1111111 Patrick J. Burke Location:M11 -SIDE ENTRY BM Alan Mascord Design Multi-Loaded Multi-Span Beam 11111 2187 NW Reed St.Ste 100 of [2015 International Building Code(2015 NDS)] Portland,OR 97210 3.5INx7.25INx5.OFT #2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:51 AM Section Adequate By:61.3% Controlling Factor: Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.03 IN L/2309 Dead Load 0.02 in Total Load 0.04 IN L/1370 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria:L/240 REACTIONS A Live Load 635 lb 719 lb 1 Dead Load 437 lb 496 lb Total Load 1072 lb 1215 lb Bearing Length 0.49 in 0.56 in BEAM DATA Center Span Length 5 ft Unbraced Length-Top O ft A 5 ft Unbraced Length-Bottom 5 ft Live Load Duration Factor 1.00 Notch Depth 0.00 UNIFORM LOADS Center MATERIAL PROPERTIES Uniform Live Load 0 plf #2-Douglas-Fir-Larch Uniform Dead Load 0 plf Base Values Adjusted Beam Self Weight 6 plf Bending Stress: Fb= 900 psi Fb'= 1170 psi Total Uniform Load 6 plf Cd=1.00 CF=1.30 POINT LOADS-CENTER SPAN Shear Stress: Fv= 180 psi Fv'= 180 psi Load Number One Cd=1.00 Live Load 472 lb Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Dead Load 315 lb Comp. L to Grain: Fc- L= 625 psi Fc--- = 625 psi Location 2 ft Controlling Moment: 1853 ft-lb TRAPEZOIDAL LOADS-CENTER SPAN 2.0 Ft from left support of span 2(Center Span) Load Number One Two Created by combining all dead loads and live loads on span(s)2 Left Live Load 235 plf 76 plf Controlling Shear: -1215 lb Left Dead Load 158 plf 50 plf At right support of span 2(Center Span) Right Live Load 235 plf 101 plf Created by combining all dead loads and live loads on span(s)2 Right Dead Load 158 plf 67 plf Load Start 2 ft O ft Comparisons with required sections: Req'd Provided Load End 5 ft 2 ft Section Modulus: 19.01 in3 30.66 in3 Load Length 3 ft 2 ft Area(Shear): 10.13 in2 25.38 in2 Moment of Inertia(deflection): 19.48 in4 111.15 in4 Moment: 1853 ft-lb 2989 ft-lb Shear: -1215 lb 3045 lb page Project:2376a solstice custom homes EN Patrick J. Burke / • Location:M12-FRONT ENTRY BM Alan Mascord Design Multi-Loaded Multi-Span BeamIII2187 NW Reed St. Ste 100 of [2015 International Building Code(2015 NDS)] .„.11.4,i40,04.0!.... Portland,OR 97210 3.5 IN x 5.51N x 7.0 FT ' #2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:51 AM Section Adequate By:63.1% Controlling Factor:Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.07 IN L/1195 Dead Load 0.05 in Total Load 0.12 IN L/701 Live Load Deflection Criteria: 0360 Total Load Deflection Criteria:L/240 REACTIONS A B Live Load 354 lb 354 lb Dead Load 249 lb 249 lb Total Load 603 lb 603 lb Bearing Length 0.28 in 0.28 in BEAM DATA Center Span Length 7 ft Unbraced Length-Top 0 ft A — —7 ft - B Unbraced Length-Bottom 7 ft Live Load Duration Factor 1.00 Notch Depth 0.00 UNIFORM LOADS Center MATERIAL PROPERTIES Uniform Live Load 101 plf #2-Douglas-Fir-Larch Uniform Dead Load 67 plf Base Values Adjusted Beam Self Weight 4 plf Bending Stress: Fb= 900 psi Fb'= 1170 psi Total Uniform Load 172 plf Cd=1.00 CF=1.30 Shear Stress: Fv= 180 psi Fv'= 180 psi Cd=1.00 Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Comp.1 to Grain: Fc-L= 625 psi Fc- = 625 psi Controlling Moment: 1055 ft-lb 3.5 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Controlling Shear: -603 lb At right support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Comparisons with required sections: Req'd Provided Section Modulus: 10.82 in3 17.65 in3 Area(Shear): 5.02 in2 19.25 in2 Moment of Inertia(deflection): 16.61 in4 48.53 in4 Moment: 1055 ft-lb 1720 ft-lb Shear: -603 lb 2310 lb page Project:2376a solstice custom homes111111 Patrick J. Burke Location:M13-FRONT FOYER BM Alan Mascord Design Multi-Loaded Multi-Span Beam Ell 2187 NW Reed St.Ste 100 of [2015 International Building Code(2015 NDS)] 9 ._Portland,OR 97210 3.5 IN x 7.25 IN x 7.0 FT - #2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:51 AM Section Adequate By:40.5% Controlling Factor: Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.05 IN L/1832 Dead Load 0.06 in Total Load 0.11 IN L/796 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria: L/240 REACTIONS A Live Load 529 lb 529 lb Dead Load 688 lb 688 lb Total Load 1217 lb 1217 lb Bearing Length 0.56 in 0.56 in BEAM DATA Center Span Length 7 ft Unbraced Length-Top O ft A 7 ft Unbraced Length-Bottom 7 ft Live Load Duration Factor 1.00 Notch Depth 0.00 UNIFORM LOADS Center MATERIAL PROPERTIES Uniform Live Load 151 plf #2-Douglas-Fir-Larch Uniform Dead Load 191 plf Base Values Adjusted Beam Self Weight 6 plf Bending Stress: Fb= 900 psi Fb'= 1170 psi Total Uniform Load 348 plf Cd=1.00 CF=1.30 Shear Stress: Fv= 180 psi Fv'= 180 psi Cd=1.00 Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Comp. L to Grain: Fc-L= 625 psi Fc---'= 625 psi Controlling Moment: 2128 ft-lb 3.5 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Controlling Shear: 1216 lb At left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Comparisons with required sections: Req'd Provided Section Modulus: 21.83 in3 30.66 in3 Area(Shear): 10.14 in2 25.38 in2 Moment of Inertia(deflection): 33.52 in4 111.15 in4 Moment: 2128 ft-lb 2989 ft-lb Shear: 1216 lb 3045 lb page Project:2376a solstice custom homes Ell Patrick J. Burke Location:M14-FOYER BM @ CENTER STAIR Alan Mascord Design Multi Loaded Multi Span Beam 2187 NW Reed St. Ste 100 or [2015 International Building Code(2015 NDS)] Portland,OR 97210 3.5 IN x 9.25 IN x 9.0 FT #2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:51 AM Section Adequate By:2.7% Controlling Factor:Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.14 IN L/795 Dead Load 0.04 in Total Load 0.17 IN L/626 Live Load Deflection Criteria: U360 Total Load Deflection Criteria:L/240 REACTIONS A Live Load 1530 lb 1530 lb Dead Load 414 lb 414 lb Total Load 1944 lb 1944 lb Bearing Length 0.89 in 0.89 in BEAM DATA Center Span Length 9 ft Unbraced Length-Top O ft A -9 ft B Unbraced Length-Bottom 9 ft Live Load Duration Factor 1.00 Notch Depth 0.00 UNIFORM LOADS Center MATERIAL PROPERTIES Uniform Live Load 340 plf #2-Douglas-Fir-Larch Uniform Dead Load 85 plf Base Values Adjusted Beam Self Weight 7 plf Bending Stress: Fb= 900 psi Fb'= 1080 psi Total Uniform Load 432 plf Cd=1.00 CF=1.20 Shear Stress: Fv= 180 psi Fv'= 180 psi Cd=1.00 Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Comp.1 to Grain: Fc- = 625 psi Fc--- = 625 psi Controlling Moment: 4374 ft-lb 4.5 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Controlling Shear: 1944 lb At left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Comparisons with required sections: Req'd Provided Section Modulus: 48.6 in3 49.91 in3 Area(Shear): 16.2 in2 32.38 in2 Moment of Inertia(deflection): 104.55 in4 230.84 in4 Moment: 4374 ft-lb 4492 ft-lb Shear: 1944 lb 3885 lb page Project:2376a solstice custom homes III Patrick J. Burke / Location: M15-HALL/GREAT RM OPN'G HDR Alan Mascord Design Multi-Loaded Multi-Span Beam 2187 NW Reed St.Ste 100 of [2015 International Building Code(2015 NDS)] ___41,40,0%„6.. Portland,OR 97210 5.5INx9.5INx7.OFT #2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:51 AM Section Adequate By:8.1% Controlling Factor:Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.08 IN L/1103 Dead Load 0.02 in Total Load 0.10 IN L1872 Live Load Deflection Criteria: U360 Total Load Deflection Criteria: L/240 REACTIONS A Live Load 2520 lb 2520 lb Dead Load 670 lb 670 lb Total Load 3190 lb 3190 lb Bearing Length 0.93 in 0.93 in BEAM DATA Center Span Length 7 ft Unbraced Length-Top O ftA 7 ft B Unbraced Length-Bottom 7 ft Live Load Duration Factor 1.00 Notch Depth 0.00 UNIFORM LOADS Center MATERIAL PROPERTIES Uniform Live Load 720 plf #2-Douglas-Fir-Larch Uniform Dead Load 180 plf Base Values Adjusted Beam Self Weight 11 plf Bending Stress: Fb= 875 psi Fb'= 875 psi Total Uniform Load 911 plf Cd=1.00 CF=1.00 Shear Stress: Fv= 170 psi Fv'= 170 psi Cd=1.00 Modulus of Elasticity: E= 1300 ksi E'= 1300 ksi Comp.L to Grain: Fe--1-= 625 psi Fc--- = 625 psi Controlling Moment: 5582 ft-lb 3.5 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Controlling Shear: 3190 lb At left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Comparisons with required sections: Req'd Provided Section Modulus: 76.55 in3 82.73 in3 Area(Shear): 28.14 in2 52.25 in2 Moment of Inertia(deflection): 128.21 in4 392.96 in4 Moment: 5582 ft-lb 6032 ft-lb Shear: 3190 lb 5922 lb page Project:2376a solstice custom homesER Patrick J.Burke • Location: M16-DINING/GREAT RM OPN'G HDR Alan Mascord Design Multi-Loaded Multi-Span Beam 2187 NW Reed St.Ste 100 of [2015 International Building Code(2015 NDS)] • Portland,OR 97210 5.5INx9.5INx7.OFT #2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:51 AM Section Adequate By:21.4% Controlling Factor: Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.07 IN L/1241 Dead Load 0.02 in Total Load 0.09 IN L/979 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria:L/240 REACTIONS A Live Load 2240 lb 2240 lb Dead Load 600 lb 600 lb Total Load 2840 lb 2840 lb Bearing Length 0.83 in 0.83 in BEAM DATA Center Span Length 7 ft Unbraced Length-Top 0 ft A eft_ - B Unbraced Length-Bottom 7 ft Live Load Duration Factor 1.00 Notch Depth 0.00 UNIFORM LOADS Center MATERIAL PROPERTIES Uniform Live Load 640 plf #2-Douglas-Fir-Larch Uniform Dead Load 160 plf Base Values Adjusted Beam Self Weight 11 plf Bending Stress: Fb= 875 psi Fb'= 875 psi Total Uniform Load 811 plf Cd=1.00 CF=1.00 Shear Stress: Fv= 170 psi Fv'= 170 psi Cd=1.00 Modulus of Elasticity: E= 1300 ksi E'= 1300 ksi Comp.-L to Grain: Fc- = 625 psi Fc--i-'= 625 psi Controlling Moment: 4969 ft-lb 3.5 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Controlling Shear: 2840 lb At left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Comparisons with required sections: Req'd Provided Section Modulus: 68.15 in3 82.73 in3 Area(Shear): 25.06 in2 52.25 in2 Moment of Inertia(deflection): 113.96 in4 392.96 in4 Moment: 4969 ft-lb 6032 ft-lb Shear: 2840 lb 5922 lb page Project:2376a solstice custom homes in Patrick J. Burke Location:M17-HALL/NOOK OPN'G HDR Alan Mascord Design Multi-Loaded Multi-Span Beam lila 2187 NW Reed St.Ste 100 of [2015 International Building Code(2015 NDS)] . Portland,OR 97210 3.5 INx5.5INx4.0FT #2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:52 AM Section Adequate By: 33.7% Controlling Factor: Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.03 IN L/1407 Dead Load 0.01 in Total Load 0.04 IN L/1117 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria:L/240 REACTIONS A Live Load 920 lb 920 lb Dead Load 238 lb 238 lb Total Load 1158 lb 1158 lb Bearing Length 0.53 in 0.53 in BEAM DATA Center Span Length 4 ft Unbraced Length-Top 0 ft d Oft B Unbraced Length-Bottom 4 ft Live Load Duration Factor 0.90 Notch Depth 0.00 UNIFORM LOADS Center MATERIAL PROPERTIES Uniform Live Load 460 plf #2-Douglas-Fir-Larch Uniform Dead Load 115 plf Base Values Adjusted Beam Self Weight 4 plf Bending Stress: Fb= 900 psi Fb'= 1053 psi Total Uniform Load 579 plf Cd=0.90 CF=1.30 Shear Stress: Fv= 180 psi Fv'= 162 psi Cd=0.90 Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Comp.-I-to Grain: Fc- = 625 psi Fc- = 625 psi Controlling Moment: 1158 ft-lb 2.0 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Controlling Shear: 1158 lb At left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Comparisons with required sections: Reci'd Provided Section Modulus: 13.2 in3 17.65 in3 Area(Shear): 10.73 in2 19.25 in2 Moment of Inertia(deflection): 12.42 in4 48.53 in4 Moment: 1158 ft-lb 1548 ft-lb Shear: 1158 lb 2079 lb page Project:2376a solstice custom homesEll Patrick J. Burke Location: M18-REAR DECK ROOF BM @ STAIR SIDE Alan Mascord Design Multi-Loaded Multi-Span Beam nin 2187 NW Reed St. Ste 100 or [2015 International Building Code(2015 NDS)] r Portland,OR 97210 5.5 IN x 11.5 IN x 9.0 FT -- r9ik»� #2 Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:52 AM Section Adequate By: 16.7% Controlling Factor: Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.06 IN L/1706 Dead Load 0.04 in Total Load 0.11 IN L/1003 Live Load Deflection Criteria: U360 Total Load Deflection Criteria: L/240 REACTIONS A Live Load 1761 lb 1129 lb Dead Load 1234 lb 812 lb Total Load 2995 lb 1941 lb Bearing Length 0.87 in 0.56 in TR1 BEAM DATA Centerticammwswiiimisamormatt Span Length 9 ft Unbraced Length-Top 0 ft A 9f Unbraced Length-Bottom 9 ft Live Load Duration Factor 1.00 Notch Depth 0.00 UNIFORM LOADS Center MATERIAL PROPERTIES Uniform Live Load 0 plf #2-Douglas-Fir-Larch Uniform Dead Load 0 plf Base Values Adjusted Beam Self Weight 14 plf Bending Stress: Fb= 875 psi Fb'= 875 psi Total Uniform Load 14 plf Cd=1.00 CF=1.00 POINT LOADS-CENTER SPAN Shear Stress: Fv= 170 psi Fv'= 170 psi Load Number One Cd=1,00 Live Load 1105 Ib Modulus of Elasticity: E= 1300 ksi E'= 1300 ksi Dead Load 736 Ib Comp.1 to Grain: Fc- = 625 psi Fc--- = 625 psi Location 4 ft Controlling Moment: 7575 ft-lb TRAPEZOIDAL LOADS-CENTER SPAN 3.96 Ft from left support of span 2(Center Span) Load Number One Two Created by combining all dead loads and live loads on span(s)2 Left Live Load 320 plf 126 plf Controlling Shear: 2995 lb Left Dead Load 213 plf 84 plf At left support of span 2(Center Span) Right Live Load 320 plf 76 plf Created by combining all dead loads and live loads on span(s)2 Right Dead Load 213 plf 50 plf Load Start Oft 4 ft Comparisons with required sections: Reci'd Provided Load End 4 ft 9 ft Section Modulus: 103.89 in3 121.23 in3 Load Length 4 ft 5 ft Area(Shear): 26.43 in2 63.25 in2 Moment of Inertia(deflection): 166.81 in4 697.07 in4 Moment: 7575 ft-lb 8840 ft-lb Shear: 2995 lb 7168 lb MIIIIL page , Project:2376a solstice custom homes in Patrick J. Burke Location:M19-REAR DECK ROOF BM-REAR Alan Mascord Design Multi-Loaded Multi-Span Beam 2187 NW Reed St.Ste 100 or �� [2015 International Building Code(2015 NDS)] e .,_Portland,OR 97210 5.125 IN x 10.5 IN x 20.0 FT 24F-V4-Visually Graded Western Species-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:52 AM Section Adequate By: 16.8% Controlling Factor: Deflection DEFLECTIONS Center LOADING DIAGRAM Live Load 0.49 IN L/494 Dead Load 0.37 in Total Load 0.86 IN L/280 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria: L/240 REACTIONS A B Live Load 1130 lb 1115 lb Dead Load 869 lb 858 lb Total Load 1999 lb 1973 lb Bearing Length 0.60 in 0.59 in BEAM DATA Center Span Length 20 ft n: : Unbraced Length-Top 0 ft2O ft A B Unbraced Length-Bottom 20 ft Live Load Duration Factor 1.00 Camber Adj. Factor 1 UNIFORM LOADS Center Camber Required 0.37 Uniform Live Load 0 plf Notch Depth 0.00 Uniform Dead Load 0 plf MATERIAL PROPERTIES Beam Self Weight 12 plf 24F-V4-Visually Graded Western Species Total Uniform Load 12 pif Base Values Adjusted TRAPEZOIDAL LOADS-CENTER SPAN Bending Stress: Fb= 2400 psi Controlled by: Load Number One Two Three Fbcmpr= 1850 psi Fb'= 2400 psi Left Live Load 76 plf 126 plf 126 plf Cd—=1.00 Left Dead Load 50 plf 84 plf 84 plf Shear Stress: Fv= 265 psi Fv'= 265 psi Right Live Load 126 plf 126 plf 76 plf Cd=1.00 Right Dead Load 84 plf 84 plf 50 plf Modulus of Elasticity: E= 1800 ksi E'= 1800 ksi Load Start 0 ft 5 ft 14 ft Comp.-1-to Grain: Fc-1= 650 psi Fc-1'= 650 psi Load End 5 ft 14 ft 20 ft Controlling Moment: 10656 ft-lb Load Length 5 ft 9 ft E ft 10.0 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Controlling Shear: 1999 lb At left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Comparisons with required sections: Req'd Provided Section Modulus: 53.28 in3 94.17 in3 Area(Shear): 11.31 in2 53.81 in2 Moment of Inertia(deflection): 423.41 in4 494.4 in4 Moment: 10656 ft-lb 18834 ft-lb Shear: 1999 lb 9507 lb Project:2376a solstice custom homes page inn Patrick J. Burke Location: M20-REAR DECK BM-GREAT RM SIDE ma Alan Mascord Design Multi-Loaded Multi-Span Beam Km2187 NW Reed St.Ste 100 of [2015 International Building Code(2015 NDS)] r Portland,OR 97210 5.5 IN x 5.5 IN x 7.0 FT -- : #2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:52 AM Section Adequate By: 13.8% Controlling Factor:Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.08 IN L/1057 Dead Load 0.06 in Total Load 0.14 IN L/618 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria: L/240 REACTIONS A Live Load 744 lb 401 lb Dead Load 518 lb 289 lb Total Load 1262 lb 690 lb Bearing Length 0.37 in 0.20 in BEAM DATA Center Span Length 7 ft4110 .` Unbraced Length-Top 0 ft A - ----7 ft B Unbraced Length-Bottom 7 ft Live Load Duration Factor 1.00 Notch Depth 0.00 UNIFORM LOADS Center MATERIAL PROPERTIES Uniform Live Load 0 plf #2-Douglas-Fir-Larch Uniform Dead Load 0 plf Base Values Adjusted Beam Self Weight 7 plf Bending Stress: Fb= 750 psi Fb'= 750 psi Total Uniform Load 7 plf Cd=1.00 CF=1.00 TRAPEZOIDAL LOADS-CENTER SPAN Shear Stress: Fv= 170 psi Fv'= 170 psi Load Number One Two Cd=1.00 Left Live Load 320 plf 126 plf Modulus of Elasticity: E= 1 1300 ksi E'=1 1300 ksi Left Dead Load 213 plf 84 plf Comp. to Grain: Fc- = 625 psi Fc = 625 psi Right Live Load 320 plf 76 plf Right Dead Load 213 plf 50 plf Controlling Moment: 1523 ft-lb Load Start 0 ft 2 ft 2.87 Ft from left support of span 2(Center Span) Load End 2 ft 7 ft Created by combining all dead loads and live loads on span(s)2 Load Length 2 ft 5 ft Controlling Shear: 1262 lb At left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Comparisons with required sections: Req'd Provided Section Modulus: 24.36 in3 27.73 in3 Area(Shear): 11.13 in2 30.25 in2 Moment of Inertia(deflection): 29.61 in4 76.26 in4 Moment: 1523 ft-lb 1733 ft-lb Shear: 1262 lb 3428 lb page Project:2376a solstice custom homes in Patrick J. Burke Location: M21 -KIT.WINDOW HDR Alan Mascord Design Multi-Loaded Multi-Span Beam 11,1112187 NW Reed St.Ste 100 of [2015 International Building Code(2015 NDS)] ___,.1,1404„-al,,..Portland,OR 97210 5.125 IN x 12.0 IN x 3.0 FT 24F-V4-Visually Graded Western Species-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:52 AM Section Adequate By: 13.9% Controlling Factor: Shear DEFLECTIONS Center LOADING DIAGRAM Live Load 0.01 IN L/6819 Dead Load 0.00 in Total Load 0.01 IN L/4129 Live Load Deflection Criteria: U360 Total Load Deflection Criteria: L!240 1 REACTIONS A B Live Load 3206 lb 5777 lb Dead Load 2049 lb 3763 lb Total Load 5255 lb 9540 lb TR2 Bearing Length 1.58 in 2.86 in w BEAM DATA Center Span Length 3 ft Unbraced Length-Top O ft A - - 3 ft B- Unbraced Length-Bottom 3 ft Live Load Duration Factor 1.00 Camber Adj. Factor 1 UNIFORM LOADS Center Camber Required 0 Uniform Live Load 390 plf Notch Depth 0.00 Uniform Dead Load 188 plf MATERIAL PROPERTIES Beam Self Weight 13 plf 24F-V4-Visually Graded Western Species Total Uniform Load 591 plf Base Values Adjusted POINT LOADS-CENTER SPAN Bending Stress: Fb= 2400 psi Controlled by: Load Number One Fb_cmpr= 1850 psi Fb'= 2400 psi Live Load 7065 lb Cd=1.00 Dead Load 4710 lb Shear Stress: Fv= 265 psi Fv'= 265 psi Location 2 ft Cd=1.00 Modulus of Elasticity: E= 1800 ksi E'= 1800 ksi TRAPEZOIDAL LOADS-CENTER SPAN Comp.1 to Grain: Fc---= 650 psi Fc-1'= 650 psi Load Number One Two Left Live Load 141 plf 465 plf Controlling Moment: 8784 ft-lb Left Dead Load 94 plf 310 plf 1.98 Ft from left support of span 2(Center Span) Right Live Load 141 plf 465 plf Created by combining all dead loads and live loads on span(s)2 Right Dead Load 94 plf 310 plf Controlling Shear: -9540 lb Load Start 0 ft 2 ft At right support of span 2(Center Span) Load End 2 ft 3 ft Created by combining all dead loads and live loads on span(s)2 Load Length 2 ft 1 ft Comparisons with required sections: Req'd Provided Section Modulus: 43.92 in3 123 in3 Area(Shear): 54 in2 61.5 in2 Moment of Inertia(deflection): 42.9 in4 738 in4 Moment: 8784 ft-lb 24600 ft-lb Shear: -9540 lb 10865 lb page Project:2376a solstice custom homes Patrick J. Burke Location: M22-NOOK PATIO DR HDR Alan Mascord Design Multi-Loaded Multi-Span Beam 11111 2187 NW Reed St.Ste 100 of [2015 International Building Code(2015 NDS)] ef Portland, OR 97210 3.51Nx9.251Nx6.OFT #2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:52 AM Section Adequate By:36.4% Controlling Factor: Moment DEFLECTIONS Center LOADING DIAGRAM Live Load 0.04 IN L/1979 Dead Load 0.02 in Total Load 0.06 IN L/1246 Live Load Deflection Criteria: U360 Total Load Deflection Criteria:L/240 REACTIONS A Live Load 1383 lb 1383 lb Dead Load 813 lb 813 lb Total Load 2196 lb 2196 lb Tai Bearing Length 1.00 in 1.00 in w BEAM DATA Center Span Length 6 ft Unbraced Length-Top O ft A s ft B Unbraced Length-Bottom 6 ft Live Load Duration Factor 1.00 Notch Depth 0.00 UNIFORM LOADS Center MATERIAL PROPERTIES Uniform Live Load 320 plf #2-Douglas-Fir-Larch Uniform Dead Load 170 plf Base Values Adjusted Beam Self Weight 7 plf Bending Stress: Fb= 900 psi Fb'= 1080 psi Total Uniform Load 497 plf Cd=1.00 CF=1.20 TRAPEZOIDAL LOADS-CENTER SPAN Shear Stress: Fv= 180 psi Fv'= 180 psi Load Number One Cd=1.00 Left Live Load 141 plf Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Left Dead Load 94 plf Comp.L to Grain: Fc-L= 625 psi Fc-L'= 625 psi Right Live Load 141 plf Right Dead Load 94 plf Controlling Moment: 3294 ft-lb Load Start 0 ft 3.0 Ft from left support of span 2(Center Span) Load End 6 ft Created by combining all dead loads and live loads on span(s)2 Load Length 6 ft Controlling Shear: 2196 lb At left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Comparisons with required sections: Req'd Provided Section Modulus: 36.6 in3 49.91 in3 Area(Shear): 18.3 in2 32.38 in2 Moment of Inertia(deflection): 44.46 in4 230.84 in4 Moment: 3294 ft-lb 4492 ft-lb Shear: 2196 lb 3885 lb page . Project:2376a solstice custom homes ini Patrick J. Burke Location:U1 -MSTR BATH TUB WINDOW HDR Alan Mascord Design Multi-Loaded Multi-Span Beam IBM 2187 NW Reed St. Ste 100 or [2015 International Building Code(2015 NDS)] �.. . i,-Portland,OR 97210 3.5 INx9.25INx6.0FT #2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:53 AM Section Adequate By: 19.3% Controlling Factor: Shear DEFLECTIONS Center LOADING DIAGRAM Live Load 0.03 IN L/2790 Dead Load 0.02 in Total Load 0.04 IN L/1653 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria: L/240 REACTIONS A B 1 Live Load 1942 lb 553 lb Dead Load 1315 lb 390 lb Total Load 3257 lb 943 lb Bearing Length 1.49 in 0.43 in BEAM DATA Center Span Length 6 ft Unbraced Length-Top 0 ft A - 6ft - B Unbraced Length-Bottom 6 ft Live Load Duration Factor 1.00 Notch Depth 0.00 UNIFORM LOADS Center MATERIAL PROPERTIES Uniform Live Load 0 plf #2-Douglas-Fir-Larch Uniform Dead Load 0 plf Base Values Adjusted Beam Self Weight 7 plf Bending Stress: Fb= 900 psi Fb'= 1080 psi Total Uniform Load 7 plf Cd=1.00 CF=1.20 POINT LOADS-CENTER SPAN Shear Stress: Fv= 180 psi Fv'= 180 psi Load Number One Cd=1.00 Live Load 1568 lb Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Dead Load 1046 lb Comp.1 to Grain: Fc--1-= 625 psi Fc-1'= 625 psi Location 1 ft Controlling Moment: 2873 ft-lb TRAPEZOIDAL LOADS-CENTER SPAN 1.02 Ft from left support of span 2(Center Span) Load Number One Two Created by combining all dead loads and live loads on span(s)2 Left Live Load 454 plf 126 plf Controlling Shear: 3257 lb Left Dead Load 302 plf 84 plf At left support of span 2(Center Span) Right Live Load 454 plf 63 plf Created by combining all dead loads and live loads on span(s)2 Right Dead Load 302 plf 42 plf Load Start 0 ft 1 ft Comparisons with required sections: Req'd Provided Load End 1 ft 6 ft Section Modulus: 31.92 in3 49.91 in3 Load Length 1 ft 5 ft Area(Shear): 27.14 in2 32.38 in2 Moment of Inertia(deflection): 33.52 in4 230.84 in4 Moment: 2873 ft-lb 4492 ft-lb Shear: 3257 lb 3885 lb page Project:2376a solstice custom homes11111 Patrick J. Burke Location:U2-STAIR LANDING SIDE WINDOW HDR Alan Mascord Design Multi-Loaded Multi-Span Beam Es 2187 NW Reed St.Ste 100 of [2015 International Building Code(2015 NDS)] Portland,OR 97210 3.5 IN x 9.25 IN x 6.34 FT '��s�'•: #2 Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:53 AM Section Adequate By:4.0% Controlling Factor: Shear DEFLECTIONS Center LOADING DIAGRAM Live Load 0.04 IN L/1872 Dead Load 0.03 in Total Load 0.07 IN L/1112 Live Load Deflection Criteria: U360 Total Load Deflection Criteria:L/240 REACTIONS A Live Load 711 lb 2227 lb Dead Load 496 lb 1507 lb Total Load 1207 lb 3734 lb Bearing Length 0.55 in 1.71 in TR2 BEAM DATA Center Span Length 6.34 ft Unbraced Length-Top O ft A - 6.34 ft Unbraced Length-Bottom 6.34 ft Live Load Duration Factor 1.00 Notch Depth 0.00 UNIFORM LOADS Center MATERIAL PROPERTIES Uniform Live Load 0 plf #2-Douglas-Fir-Larch Uniform Dead Load 0 plf Base Values Adjusted Beam Self Weight 7 plf Bending Stress: Fb= 900 psi Fb'= 1080 psi Total Uniform Load 7 plf Cd=1.00 CF=1.20 POINT LOADS-CENTER SPAN Shear Stress: Fv= 180 psi Fv'= 180 psi Load Number One Cd=1.00 Live Load 1750 Ib Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Dead Load 1167 lb Comp.-L to Grain: Fc-1= 625 psi Fc--- = 625 psi Location 5 ft Controlling Moment: 4177 ft-lb TRAPEZOIDAL LOADS-CENTER SPAN 4.95 Ft from left support of span 2(Center Span) Load Number One Two Created by combining all dead loads and live loads on span(s)2 Left Live Load 63 plf 534 plf Controlling Shear: -3734 lb Left Dead Load 42 plf 356 plf 6.0 Ft from left support of span 2(Center Span) Right Live Load 126 plf 534 plf Created by combining all dead loads and live loads on span(s)2 Right Dead Load 84 plf 356 plf Load Start Oft 5 ft Comparisons with required sections: Req'd Provided Load End 5 ft 6.34 ft Section Modulus: 46.41 in3 49.91 in3 Load Length 5 ft 1.34 ft Area(Shear): 31.12 in2 32.38 in2 Moment of Inertia(deflection): 49.82 in4 230.84 in4 Moment: 4177 ft-lb 4492 ft-lb Shear: -3734 lb 3885 lb 1 page . Project:2376a solstice custom homes ER Patrick J. Burke Location:U3-FRONT STAIR WINDOW HDR Alan Mascord Design 1111111 Multi-Loaded Multi-Span Beam 2187 NW Reed St.Ste 100 of [2015 International Building Code(2015 NDS)] _..,' .' e :_Portland,OR 97210 3.5 IN x 7.25 IN x 9.34 FT #2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 11/13/2018 11:10:53 AM Section Adequate By:32.2% Controlling Factor: Moment DEFLECTIONS Center ' LOADING DIAGRAM Live Load 0.12 IN L/971 Dead Load 0.08 in Total Load 0.20 IN L/567 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria:L/240 REACTIONS A B Live Load 474 lb 610 lb Dead Load 342 lb 433 lb Total Load 816 lb 1043 lb Bearing Length 0.37 in 0.48 in BEAM DATA Center Span Length 9.34 ft .._ --- _-- -- Unbraced Length-Top 0 ft A _9.34 ft B Unbraced Length-Bottom 9.34 ft Live Load Duration Factor 1.00 Notch Depth 0.00 UNIFORM LOADS Center MATERIAL PROPERTIES Uniform Live Load 0 plf #2-Douglas-Fir-Larch Uniform Dead Load 0 plf Base Values Adjusted Beam Self Weight 6 plf Bending Stress: Fb= 900 psi Fb'= 1170 psi Total Uniform Load 6 plf Cd=1.00 CF=1.30 TRAPEZOIDAL LOADS-CENTER SPAN Shear Stress: Fv= 180 psi Fv'= 180 psi Load Number One Two Cd=1.00 Left Live Load 63 plf 141 plf Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Left Dead Load 42 plf 94 plf Comp.-L to Grain: Fc--I = 625 psi Fc-1'= 625 psi Right Live Load 126 plf 141 plf Right Dead Load 84 plf 94 plf Controlling Moment: 2261 ft-lb Load Start O ft 5 ft 4.95 Ft from left support of span 2(Center Span) Load End 5 ft 9.34 ft Created by combining all dead loads and live loads on span(s)2 Load Length 5 ft 4.34 ft Controlling Shear: -1043 lb 9.0 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Comparisons with required sections: Req'd Provided Section Modulus: 23.19 in3 30.66 in3 Area(Shear): 8.69 in2 25.38 in2 Moment of Inertia(deflection): 47.04 in4 111.15 in4 Moment: 2261 ft-lb 2989 ft-lb Shear: -1043 lb 3045 lb