Report A -
. (\r-c_c_. \cc-00,l9k33 \L\R.) ;ci, (- „,' LI') -"\ c‘ c._..'- i\-Vio--
. W ` r
1
-. SPEEO QUEEN® QUANTUM® TOUCH
AUG 152019
Single Tumble Dryers c.-,--., , ,.,- -, -N
ST025 ST030 ST035 STO55
Control Option Quantum Touch Quantum Touch Quantum Touch Quantum Touch
Capacity-lb(kg) 25(11) 30(14) 35(16) 55(25)
Overall Width-in(rnm) 27.9(709) 27.9(709) 31.5(800) 345(876)
Overall Depth-in(mm) 39.4(1001) 45.5(1156) 45.5(1156) 53.1(1349)
Overall Height-in(mm) 63.9(1623) 63.9(1623) 63.9(1623) 66.7(1694)
Cylinder Diameter-in(mm) 26.5(673) 26.5(673) 30(762) 33(838)
Cylinder Depth-in(mm) 24.0(610) 30.0(762) 30.0(762) 35.0(889)
Cylinder Volume-cu.ft(liters) 7.7(218) 9.6(272) 12.3(348) 17.3(490)
Reversing Cylinder Option Option Option Option
Door Opening Size-in(mm) 22.7(577) 22.7(577) 22.7(577) 26.9(683)
Heat Input Gas Models-Per Pocket 64,000 Btu/hr 73,000 Btu/hr 90,000 Btu/hr 112,000 Btu/hr
Power Steam Models-Per Pocket 83,500 Btu/hr 83,500 Btu/hr 103,400 Btu/hr -
Electric Models 12kW 21kW 24kW 27kW
Gas Connections-in(npt) 0.5 0.5 0.5 0.5
Plumbing Connections-Steam-In(rcpt) 0.75 0.75 0.75 -
Air Outlet-in(mm) 6(152) 6(152) 8(200) 8(200)
Motor-HP Fan 0.3 0.3 0.3 0.5
Cylinder 0.3 0.3 03 0.5
Airflow-cfm 500 500 600 700
Electrical Gas&Steam
Specs imps B 100-120V/50/60/1 10 10 10 12
X 200-240V/50/60/1/3 6 6 6 7
N 440-480V/50/60/3 3 3 3 3
P 380-415V/50/60/3 3 3 3 3
Electric
D 200-208V/50/60/1 60 104 118 133
E 230-240V/50/60/1 53 90 102 116
F 200-208V/50/60/3 36 61 69 78
G 230-240V/50/60/3 32 52 59 67
H 380V/50/60/3 19 33 37 42
J 400-415V/50/60/3 18 30 34 39
K 440V/50/60/3 17 29 32 37
L 460-480V/50/60/3 15 27 30 34
Shipping Dimensions Width 30.0(762) 30.0(762) 33.0(838) 35.5(902)
Approx.-in(mm) Depth 43.0(1092) 49.0(1245) 49.0(1245) 57(1448)
• Height 67.6(1717) 67.6(1717) 67.6(1717) 70.5(1791)
Net Weight-lb(kg) Gas&Steam 300(136) 320(145) 340(154) 430(195)
Electric 310(141) 330(150) 350(159) 440(200)
Shipping Weight-lb(kg) Gas&Steam 320(145) 340(154) 360(163) 470(213)
Electric 330(150) 350(159) 370(168) 480(218)
Agency Approvals CSA CSA CSA CSA
Q Speed Queen.
The Proven Performer in Laundry
---- SPEED QUEEN' QUANTUM' TDUCii
Single & Stack Tumble Dryers
1
STOSO STO7S STT30 ST
Control Option Quantum Touch Quantum Touch Quantum Touch Quantum Touch
Capacity-lb(kg) 50(23) 75(34) 30(14)x 2 45(20)x 2
Overall Width-in(mm) 38.5(978) 38.5(978) 31.5(800) 34.5(875)
Overall Depth-in(mm) 46.8(1189) 53.0(1346) 42.8(1087) 48.6(1235)
Overall Height-In(mm) 77.3(1963) 77.3(1963) 76.3(1938) 81.3(2065)
Cylinder Diameter-in(mm) 37.0(940) 37.0(940) 30.0(762) 33.0(838)
Cylinder Depth-in(mm) 30.0(762) 36.0(914) 26.0(660) 30.0(762)
Cylinder Volume-cu.ft(liters) 18.7(530) 22.4(634) 10.6(300) 14.8(419)
Reversing Cylinder - - option Option
Door Opening Size-in(mm) 26.9(683) 26.9(683) 22.6(574) 26.9(683)
-
Heat Input Gas Models-Per Pocket 122,000 Btu/hr 150,000 Btu/hr 73,000 x 2 Btu/hr 95,000 x 2 Btu/hr
Power Steam-Per Pocket 113,600 Btu/hr 133,900 Btu/hr 85,400 x 2 Btu/hr -
Electric Models 30kW 36kW 21 x 2 kW
Gas Connections-in(npt) 0.5 0.5 0.5 0.5
Plumbing Connections-Steam-in(npt) 0.75 0.75 0.75 -
Air Outlet-in(mm) 8(203) 8(200) 1 x 8(200)oval 1 x 10(250)oval
Motor-HP Fan 0.5 0.5 0.3 0.5
Cylinder 0.5 0.5 0.3 0.5
Airflow-cfm 700 800 2 x 400 2 x 600
Electrical Gas&Steam
Specs-amps B 100-120V/50/60/1 9 12 16 20
X 200-240V/50/60/1/3 6 7 9 '2
N 440-480V/50/60/3 3 3 6 6
P 380-415V/50/60/3 3 3 6 6
Electric
E 230-240V/50/60/1 91 - - _
F 200-208V/50/60/3 87 104 61 x 2 -
G 230-240V/50/60/3 75 90 52 x 2 -
H 380V/50/60/3 47 56 33 x 2 -
J 400-415V/50/60/3 43 52 30 x 2 -
K 440V/50/60/3 41 49 29 x 2 -•
L 460-480V/50/60/3 38 45 27 x 2 -
Shipping Width 41.5(1054) 41.5(1054) 32.5(826) 35.5(902)
Dimensions Depth 50.0(1270) • 56.0(1422) 47.0(1194) 54.0(1372)
Approxi in(mm)
Height Gas&Electric-81.0(2057) , Gas&Electric-81.0(2057) 79.9(2029) 84.9(2156) 'c-' '
Steam-83.5(2121) Steam-83.5(2121)
Net Weight-lb(kg) Gas 660(299) (690(313) 570(259) 710(322)
Steam 690(313) 710(322) 610(277) -
Electric :680(308) = 720(327) 660(299) _
Shipping Weight-lb(kg) Gas 710(322) 740(336) 600(272) 750(340)
Steam 740(336) A 760(345) 640(290) -
1
Electric 730(331) ', 770(349) 690(313) --
Agency Approvals CSA CSA CSA CSA ___ ___
Tumble dryer models are made to suit a variety of electrical service characteristics.See your Speed Queen distributor for specifications.For further details on installation,refer to Installation,Operation
and Maintenance instructions supplied with the tumble dryer.Amperage ratings available In Installation Manual.For the most accurate Information,the installation guide should be used for all design
and construction purposes.Due to continuous product Improvements,design and specifications subject to change without notice.The quality management systems of Alliance Laundry Systems are
registered to ISO 9001.
Speed Queen by Alliance Laundry Systems AC19-0067 • 02019 Alliance Laundry Systems LLC
High BTU Stainless Steel Gas Connectors
Category B Specification Sheet
Applications AUG 1 5 ZO ict
•Boilers •Gas packs/Rooftop HVAC units -„-.,, r,r"7":?,"I i',' Designed for high BTU demand
•Gas Meters •Tankless Water Heater
•Furnaces •Stationary Standby Gas Generators* Exclusive No-Neck® 611,
•Commercial design increases flexibility ,�[u
�a
Water Heaters
CSA design-certified
•Specifically designed for application with a significant BTU requirement.
Can supply up to 1.5 million BTU (natural gas) or 2.4 million (propane), Durable 304 stainless steel 1.
depending on length. tubing '�
•Eliminates the need for pipe nipples, 90's and elbows. More corrugations per inch
• Pre-fabricated gas connector means no field threading, cutting or increase flexibility and extend
assembly of CSST fitting and tubing. service life SP
•Available with hot dipped PVC coating with antimicrobial agent, S
i 12
Safety Shield yellow coating, or Stainless Steel.
Connector Minimum Flow Capacity-For Natural Gas(per ANSI Z21.24/CSA 6.10&ANSI Z21.75/CSA 6.27)
Straight Length Capacity-BTU per Hr 0.64 SG.,1000 BTU per Cu.Ft.at 0.5 inch Water Column Pressure Drop
Series Nominal OD(in) Nominal ID(in) 12" 18'' 24" 30" 36" 48" 60" 72"
40/41/40C 1" 3/4" 349,000 318,500 290,900 270,500 255,900 215,000 197,400 173,900
50/51 1-1/4" 1" 698,000 637,000 581,800 545,200 515,900 442,700 398,900 347,800
60/61 1-1/2" 1-1/4" 1,500,000 j 1,470,000 1,200,000 1,130,000 960,000 930,000
Connector Minimum Flow Capacity-For Propane Gas(per ANSI Z21.24/CSA 6.10&ANSI Z21.75/CSA 6.27)
Straight Length Capacity-BTU per Hr 1.55 SG.,2500 BTU per Cu.Ft.at 0.5 inch Water Column Pressure Drop
Series ' Nominal OD(in) Nominal ID(in) 12" 18" 24" 30" 36" 48" 60" 72"
40/41/40C 1" 3/4" 558,400 509,600 465,440 432,800 409,440 344,000 315,840 278,240
50/51 1-1/4" 1" 1,116,800 1,019,200 930,880 872,320 825,440 708,320 638,240 556,480
60/61 1-1/2" 1-1/4" 2,400,000 2,352,000 1,920,000 1,808,000 1,536,000 1,488,000
NOTE:When using 0.2 water column pressure drop,capacity can be determined by multiplying the values above by 0.632
(for both natural and propane gas). For capacities at other than noted,contact Dormont at 1-800-DORMONT.
Approvals and Certifications Features and Specifications
•ANSI Z21.24/CSA 6.10-Connectors for Gas Appliances •Tubing Annealed,304 stainless steel (ASTM A240)
•ANSI Z21.75/CSA 6.27-Connectors for Outdoor Appliances and •Flare nuts Brass or plated steel
Manufactured Homes •Adapters Brass or plated steel
•City of New York-MEA#376-92-M •Optional coating Heavy-duty,antimicrobial,hot-dipped gray PVC
(41,51 &61 series).Coating will not
•Approved by the Commonwealth of Massachusetts Board of State hold a flame.
Examiners of Plumbers and Gas Fitters-connector length may not •Approved for indoor and outdoor use
exceed 36". •Operating temperature with adapters:-40°F to 150°F
* Tested and passed vibration criteria set forth in UL2200,section 35.1.3.3, •100%leak tested
"Stationary Engine Generator Assemblies,"and UL536,section 7, •When installing a new appliance or when an existing appliance is moved to
"Flexible Metallic Hose." a new location a NEW gas connector must be used per manufacturer's
installation instructions and per product standards ANSI Z21.24/CSA 6.10
ALL INSTALLATIONS MUST COMPLETELY COMPLY WITH ALL and ANSI Z21.75/CSA 6.27.
DORMONT MANUFACTURING COMPANY WARNINGS AND •Avoid repeated bending,flexing,or extreme vibration.Do not use on
INSTRUCTIONS,NATIONAL,STATE AND LOCAL CODES AND portable gas generators due to excessive vibration
ALL APPLICABLE ANSI STANDARDS. •Not suitable for moveable installations.Not NSF certified.
',--..f 40/41.
50/51 and 60/61 series only are IAPMO approved
1-800-DORMONT
www.dormont.com