Report (44) oaa3G itiNSWIiirecillk, •
CT E c,I 4. 60
INC W
180 Nickerson St.
AA
Suite 302
R EG of N� Seattle,WA 98109
'4222 X1 c�� (206)285-4512(V)
IFS T G\k\ (206)285-0618(F)
asolomon@ctengincering.com
8/14/2019
BULLETIN
Date: August 14,2019 Number: CT-62 Project#: 15238
Project Name: River Terrace SF Attached: None
Subject: Lot 215 (Plan 3410B)—Header for Garage Wall Electrical Panel
Drawings Affected:
Description/Action:
This bulletin provides response to RFI's, design clarifications and/or variation requests for the `River
Terrace SF' project located in Tigard, Oregon.
Based on our review of the plans &the information & construction photos provided by Polygon, the
GLB 3.5" x 9.5" header& supporting cripple studs for the garage wall electrical panel are acceptable
for the given loading condition. No change is required.
CALL WITH ANY OUESTIONS
Issued by: Yashar E.Zafari Date: Auq. 14, 2019
Distribution:
Contact Information:
Paul McColm Pcgon Northwest Company
Frank Sandoval te_c`ivgon Northwest Company
Chris Roberts Polygon Northwest Company
David Burnett Milbrandt Architects
R:\15238 River Terrace SF\Bulletins\15238_2019.08.14_CT62_Lot 215(Plan 3410B)-Header for Garage Wall Electrical Panel.doc
Structural Engineers
CT ENGINEERING GJ
• �4
'60 �; ,
INC W .+ 180 Nickerson St.
'4 �� Suite 302
a , A REGON& Seattle,WA 98109
`a,� �� (206)285-4512(V)
22, c� 206 285-0618
Orbit asolomon@ctengincering.corn
8/14/2019
BULLETIN
Date: August 14, 2019 Number: CT-63 Project#: 15238
Project Name: River Terrace SF Attached: None
Subject: Lot 215 (Plan 3410B)—Drilled Holes in LVL Beam
Drawings Affected:
Description/Action:
This bulletin provides response to RFI's, design clarifications and/or variation requests for the 'River
Terrace SF' project located in Tigard, Oregon.
Based on our review of the plans & the information & construction photos provided by Polygon
regarding the 1-3/4" x 14" LVL beam with three 1" diameter electrical holes drilled through. A
Simpson MSTA24 strap should be attached along the bottom of the beam, where the drilled holes
are located.
--411111160014
y
CALL WITH ANY QUESTIONS
Issued by: Yashar E.Zafari Date: Auq. 14, 2019
Distribution:
Contact Information:
Paul McColm Polygon Northwest Company:__
Frank Sandoval Polygon Northwest Company i,
Chris Roberts Polygon Northwest Company
David Burnett Milbrandt Architects
R:\15238 River Terrace SF\Bulletins115238 ' 19.08.14_CT63_Lot 215(Plan 34108)-Drilled Holes in LVL Beam.doc