Loading...
Report (39) kI'lks(KA\--\ e , SThlii g llIS Submittal D-PSS-1.0 5-10-06 e Leader in Air Management PSS • Supply . Star Pattern Perforated Ceiling Diffusers • Steel . Flush Face AUG 0 kt 2.B1 9, Nt°:3 o r d e r Type 3 (Lay-In) Nominal --, Duct Size D ..- -"---D minus 1/8" --4-.1 I 1 /Star Deflector 1 , / l' 3" / 1 //// \\\\ i \ P 10 i 1 1 --.. Ceiling Module minus 1/4" —.--1 -... Ceiling Module Size *- IIII .- ier Type 1 (Surface Mount) 0 Border Type 2 (Snap In) Nominal Face Size minus 1" 7 -1"Border 4---W : ] i V 1 1 r 01 CiMg 11 i_ L .11 ---. a • fs a a • Pr. - Nominal Face Size --*-- Ceiling Module Size ..., Nominal Face Size plus 1" ..- minus 1/16" El Border Type 4 (Spline) lb tt o rd e r Type 4SL(Spline Side Lock) ...1:2..1; .--N tP.V1 „AM : .". amuse _ owe a*.•• r. = '`,41111111=' .........- ICIIWZAarl- . -.4.1 .. . ...: Ceiling Module Size eiling Module Size --.-1 minus 1/16" minus 1/16°' Note:4SL can be instated after ceiling tiles are in place. -- ------------------ - -- — Available Sizes for Border Types 1, 2, 3, 4, 4SL Face or Nominal Duct Size D Ceiling 6 x 6 8 x 8 10 x 10 12 x 12 6" Dia, 8"Dia. 10" Dia, 12" Dia. 14" Dia, 16" Dia. Module Size .... .. 12x12 - • 24 x 24 • • • • • = - = • • _ ... • Indicates available combination All dimensions are in inches. D—PSS-2.0 5-10-06 Available Discharge Patterns XSide Blow n , Corner Blow 0 Field Adjusted 4 # Plan \lt/ View • Plan (---;- a ---0, ) View it . 40 * 1 Ai N Plan Vit View \\-} _ Back blades can be redirected to Factory Set,4 Way Factory Set,4 Way produce directional adjustment Not available with 12 x 12 neck size. pattern as shown above. Exterior Zone Applications Illustrating Wall Effect Ceiling Ceiling Ceiling """'\,''\;,,,22.w ,,,I, f%7Z,.:','`;;Z• .,/ /,‘;,'" , . ',.v/Z/Z.Z.Zz.'11..,,/-7 A 5'27 47.7"/,/,,:/A: '-'..',.:.7.7 Z12 ..Z.,':A - , , \ / . / , , ' , I- , # \ 9 \ # if / / Elevation , / Elevation \ / AL Elevation \ ' Wall Wail , ;Wall ',"!2/.'......:.11, ./. _A ,C,icittrhnzrebclotrona; „„ / ,, . . , \._. __ Side blow , Corner blow , . ‘ N Plan, : / , \ \ adjustment gives gives maximum v .i , gives maximum Plan ,,,• -' , View: J spread. View maximum wall throw. - Plan ' • coverage. View L Interior Zone Applications n # , , . .‘ , ,„,‘ / I 1 ,,,,, filt I•1,..i , / , ,.--- + Plan View [ . $.- \'7 '4' ..4 Plan It 4 / ..,- / \.„. _...— ---, View \-.../ A ,..., i „,, orner blow with directional ,r,'' Alternating side blow and corner blow setting allow diffuser to be closely spaced without creating down drafts that would otherwise adjustment fills cornerwalls to avoid drafts, result from two air streams coiliging head-on. Field Adjustments , , IIIIIIIIIIIIIIIIIIIIIII • .,. n n . .... , ,.....„--. ......„,„ > r— 111 .... Amomew , '0 7'' 1 1 ,' / 1 ( \I/ .... 0 1 ) SECIM Pattern can be changed from side blow to A A .F.f?.4./... corner blow and vice versa by removing l',,,A-). r four screws,rotating deflector 45 degrees, L3ACK BLACC; CAN,-;- 1-,F":RF:Ta; ';',PF,Oin CE and replacing screws. DEC/ON/C AD.L'.-RENI ,,AFT-P^, A',,HOWN ABOVE. 1 . . D-PSS-3.0 5-10-06 Accessories (Optional) for Round Neck Check 1-Q1/ if provided. O Model AG-100 Radial Sliding Blade Damper 0 Model D-100 Radial Sliding Blade Damper 0 Model EG Equalizing Grid 0 Model EG Equalizing Grid • —AG-100 EG \Mounts Above Neck t EG 1 gligan \ 1 1/2" Intfigli D-100 I i I \ :ounts on Neck alinitinilt1 13/4 ::::•fati&t.kerkke4wa.,:km iii 1 J \•._. Model AG-100 damper is available in duct Model D-100 damper is available in duct sizes 6 thru 14 inches only. sizes 6 thru 14 inches only. O Model D-75 Opposed Blade Damper 0 Model AG-85 Butterfly Damper O Model EG Equalizing Grid 0 Model EG Equalizing Grid \ AG-85 EG _ 0-75 I EG \ Mounts Above Neck 1 1/2" eigna \Mounts on Neck ON. 4iik. )*4 KgRik Me% AbANA. k.;:ltMele4.-4:Eiiiitiiiiiiieka3 (... f A i „, 44:Mvoig \ , i,," ii:XiMUSA:::J \ .. JaintEleghlgettg 1 5/8"A ::si::teiegmi:mtatiz4mikt ‘... i Model D-75 damper is available in duct sizes 6 thru 12 inches only. O Model AG-65 Combination Damper and Equalizing Grid 0 Model AG-75 Opposed Blade Damper 0 Model EG Equalizing Grid r AG-65 \ AG-75 Air Flow -- ,/ Mounts Above Neck A i EG \ Mounts Above Neck la , i 1 1 1/2" TORDINESANIF 11/2" :lea $4 ' ,.. exiii::-. A 11 f estax .mr,fia, , liiiW4:71111 B f ) .... Dimension "A"in Inches, for Dampers Shown on Preceding Page and Above Accessories Nominal Round Duct Sizes Note: Model AG-100 and D-100 dampers 6 8 10 12 14 16 have radial blades that slide in a horizontal AG-100 — — — N/A plane. For that reason, no opening -- -. . -- - - .- - - . •-•; -..- --- . '-- D-100 — — — — N/A clearance A„is dimensioned. D-75 2 3/8 3 1/4 4 1/8 4 7/8 N/A N/A AG-85 ' 2 1/2 3 1/2 4 1/2 5 1/2 6 1/2 7 1/2 AG-65 3 3/8 4 1/2 5 1/2 7 1/8 8 5/8 9 7/8 AG-75 4 1/4 5 1/8 6 6 7/8 2 3/4 3 1/2 D-PSS-4X) 5-10-06 Accessories (Optional) for Rectangular Neck Check ff'if provided. O Model AG-95 Opposed Blade Damper 0 Model AG-35B Opposed Blade Damper • Model EG Equalizing Grid 0 Model EG Equalizing Grid • EG AG-95T Mountson Neck EG AG-35B 1 112" MINA / 11 jFirlin / Mounts , in Duct i:,44:et:Ziliritreriiii*44 1 3/4" tit!.tat 21/16 I \ Slot Operator(Type 1) Slot Operator (Remove Face for Access) (Remove Face for Access) Accessories (Optional) Check 'if provided. 0 TRM TITUS Rapid Mount Frame - 111901111 —91 For Surface Mounting Border Type 3 0 1B Molded Insulation Blanket „it/04 ,A11111-nr , Insulation is R-6 where blanket has the • . . most depth.One-inch clearance on each side of neck is left for insulated duct 44.4 connection.24 x 24-inch module size only. Blanket is factory installed Standard Finish: #26 White General Description • Model PSS perforated star diffuser • Model PSS is available with • Perforated face is hinged to allow is_designed to provide a high -either side blow or comer blow. access to the star deflector. The induction air pattern that maximizes Side blow maximizes throw damper(where used) is adjustable throw distance. distance. Corner blow maximizes after removal of the star deflector. wall surface coverage in a • Excellent performance in variable perimeter installation. • Perforated face has 3/16"diameter air volume systems. holes on 'A"staggered centers. • Model PSS can be changed to • PSS deflector is mounted directly either side blow or corner blow in • Inlet collar is approximately 116" under the neck of the diffuser to the field. deep to allow easy duct connection. generate the long-throw star pattern. • Vertical air pattern can be • Material is heavy gauge steel. obtained by turning all deflector • Air direction can be field adjusted blades inward. with no increase in pressure drop or sound level. This submittal is meant to demonstrate general dimensions of this product.The drawings are not meant to detail every aspect of the product.Drawings are not to scale Titus reserves the right to make changes without written notice •