Wormald Fire Systems Operation & Maintenace "OPERATION AND MAINTENANCE MANUALS" FOR TIGARD CIVIC CENTER 103055 SW HALL TIGARD, OREGON SEPTEMBER 19, 1986 WIG MAL FIRE SYSTEMS WORMALD FIRE JTEMS 1106 54th Avenue East Tacoma, WA 98424 SUBJECT: TIGARD CIVIC CENTER l,K)kf`1ACd; j08: 424-00822 l.ix";1i [()1\: TIGARD, OREGON NQ. ITEM SPEC. MANUFACTOREP " ?! I I ;1 X !tF;MAPKS 1 SWING CHECK VALVE RELIABLE DW 4" FOR FIRE DEPT. CONNECTION 2 O.S.&Y GATE VALVE KENNEDY 68 3" & 4" CONTROL VALVE 3 TAMPER SWITCH POTTER ELECTRIC SYS-UA1 FOR CONTROL VALVE 4 ELECTRIC BELL WHEELOCK 43-G6-115 6" ALARM BELL, 5 SWING CHECK VALVE UNITED BRASS 99S 2" FOR ANTI-FREEZE SYSTEM 6 BUTTERFLY VALVES MILWAUKEE BB-SC100 2" FOR ANTI-FREEZE SYSTEM 7 FIRE DEPARTMENT CONN. STANDARD FIRE WEST S-133 "x22"x2'2 FIRE DEPARTMENT CONN. 8 BACKFLOW PREVENTOR HERSEY NO. 2 4" 9 WATERFLOW INDICATOR NOTIFIER WFD 4" 10 SPRINKLER HEAD RECESSED RELIABLE G 12" 11NDARD. SPRINKLER HEAD RELIABLE _�G -` -2" Bulletin 803C Model D °° ® 4" Swing CO lailablimCheck Valves0 Features 1. Two connection styles available: .: Wafer type—Model DW Grooved end type—Model DG 2. Easily installed compact lightweight design 3. Resilient `O' ring seating provides: Leaktight sealing, antlstick operation, RAN . simple field replacement 4. Approved for vertical and horizontal Model DW Wafer check Valve installation 5. Listed by Underwriters Laboratories, Inc. �--� Approved by Factory Mutual Research Corporation, N.Y City, B.S. &A. No. 587-75-SA 31, Reliable Model D Swing Check Valves are general pur- ` pose valves which perform all regular check valve duties. m Both models are approved for use in fire protection sys- tems, typical applications include connections between7-8 public water supplies and private fire systems, at the discharge from fire pumps, at gravity tank connections Model DG Grooved End Check Valve and at fire department pumper connections. These valves provide leak tight, non stick operation through the use of a resilient`O' ring seal installed in the valve's seat. The Model DG Grooved End Check Valve is also easily This seal is field replaceable for easy maintenance. installed using mechanical grooved couplings.This valve The Model DW Wafer Check Valve is Basil installed also provides easy inspection and repair by removing the y couplings and slipping the valve out from between its between standard Class 125 flanges with gaskets using connections. one set of flange studs. Inspection and repairs are easily accomplished by loosening the studs and slipping the valve out from between the flanges. The Reliable Automatic Sprinkler Co.,Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Valve Description 8. UL Guide No.—HMER 1. Rated Working Pressure:250 psi(17,23 bar) 9. Ordering Information 2. Factory Hydrostatic Test Pressure:500 psi(34,47 bar) Specify 3. Stud Length (not supplied): 85/8"x 9" double ended 4"Model DW-Wafer Check Valve P/N 6104040000 or stud bolts and 16 nuts, Model DW-Wafer style only. 4"Model DG-Grooved End Check Valve P/N 4. Groove Dimensions DG Boss B 0015 Model : y ( ) Boss Tapping—/2 NPT(if required) Outside dia.4.500"(114.3 mm) Groove dia.4.334!'(110.1 mm) Item Groove width 3/8"(9.5 mm) No. Part Name Part Number Quantity Face of Valve to Groove 5/8"(15.9 mm) 1 oder 91006824 1 5. Friction Loss—Expressed in equivalent length of pipe, Grooved Ends 91006815 1 based on Hazen Williams formula with C = 120 2* Seat Ring 960"24 1 Equiv. Length 3 10'Ring 95446823 1 4"Models DW and DG 9.8 ft. (3.0) 4 Clapper 91906824 1 6. Shipping Weight 5 Hinge Pin 95006824 1 4"Model DW-17 lbs. (7.7 kg) 6 Plug 1/4" 1 98604403 2 4"Model DG-17 lbs. (7.7 kg) 7 Plug lb" 98604402 1 7. UL Control No.-143V 8 Label 94392009 .1 *Not field replaceable. 5 1 4 2 3 8 8 I I 6 I I I , r-+-fi-- I I i II I I I I I I -4 BossA Boss --- --J 1111 —— — _——--- _ �- _ (Typical Both Models) 8„ 51/21 Boss A Factory Tapped to 1/2'NPT.Boss B may be tapped to 1/2'NPT The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Reliable Sprinkler Devices,protecting life and property for over 60 years,are approved by all fire insurance and government agencies,and are installed and serviced by Reliable's chain of representatives. Reliable representatives,located throughout the United States,Canada and foreign countries,have a life-time of experience and are as near as your telephone. Manufactured by The Reliable � Automatic Sprinkler Co.,Inc. RellabIl 525 North MacQuesten Parkway Mount Vernon,New York 10552 (914)66$_3470 (S)PRINTED IN U.S.A.12185 KENNEDY IRON GATE VALVE outside-screw-and-Yoke (os&Y) Underwriters'/Factory Mutual 't Kennedy. Outside-Screw-and-Yoke Gate Valves Working Pressures: are designed for use in cold water fire line'piping 2W through 12" Cold Water, systems: Ikon-Shack 175 lbs. Bonnet markings "UL" and ",4FM►" ,signify 14" Gold Water, Non-Shock 150 lbs. these valves are listed by Underwriters' Labora Hydrostatic Test Pressures: tories and approved by Factory Mutual Fire In 2Y2"through 12"Seat&Shell 350 psi. surance companies. 14" Seat&Shell 300 psi. Construction: - ■ Iron Body ■ Bronze Mounted ■ Double Disc: ■ Parallel Seats - f - I FIG. 67 FIG. tib SCREWED FLANGE© SIZES:2'h"THRU 4" SIZES:-2'z"THRU 14" PENNED Y. 1tAL VE Division of ITT Grinnel#Veixe Co- Inc: A` [RON GATE VALVE Working pressures: ■ Outside-Screw-and-Yoke 21h"-12"Cold Water, Non-Shock 175'ibs. ■ Bronze Mounted IJnderurr2ters'/Factory Mutual 14"—Cord Water, Non-Shock-150 lbs. ■ Parallel Seats ■ Double Disc ■ 212"through 14" �� ` HYDROSTATIC TEST PRESSURE:2'h"—12"Seat l;<Shell—350 psi. 14°Seat&Shell—300 psi. - Part No. DESCRIPTION MATERIAL A.S.T.M. PEE 1 Lock Nut Bronze B-62 2 Handwheei' Cast Iron A-126 Glass B= ter• 3 ' Washer Bronze B-62 FIG. 6$ Yoke Nut Bronze B-62 Flanged Ends _ Stem Bronze Rod B-16 6 Yoke Cast Iron A-126 Class B 7 Hex Nuts Bronze B-16 $ 8' Gland Follower Cast Iron A-126 Class B 9 Gland ronze B-62 10 Hex Head Batts teal Rust Proof) A-307 8 11 Packing Graph. Asbestos Teflon Asbestos 17 goonet Bashing Bronze B-135 Alloy 2* 13 Yolle to Bonnet Bolts & Nuts Steel A-307 Grade B 14 TBonnet Cast Iron A-126 Class B, 15 Gasket Asbiitos Sheet I6 Bonnet Baits & Nuts Steel A-307 Grade B F 17 Stem Reid ang: Bronze B1584 Alloy 086400 1 I8 Disc Rings Bronze B-62 2 �. I9 Discs Cast Iron A-126 Class B 0 Seat Rings Bronze 8-62 3 21 Wedge Pins Bronze 942 22 Body ast Iron A-126 Class B 4 *14"SIZE MATERIAL IS ASTM B-62 STEM K SIZE A B C D E F G H i K ; WA. 7 2'fr , 77T 7 1 1 Ya 5� 81 7 1 6 Ys 3/ 3. 8 7 l 151e 19.a 1Q 10%2 6 V2 l ya- $ 39 8'/2 83 11s 161/s 24ys 8 10% 1 8 1 V1s ye f OPEN g 4 9 9 13/4 18 ".22 4 16` 14 8 1z ,life; ( to 5 10 10 2 203/4 26"el 10 111 8 1fY 1118 B 'C#gSE>i 11 1 i 1 2/ 243/s 30 Ya T2 20 `i0 112I'la 1 Q 14, f28 1I/131/zY2 1/x. Y2 1 10 1 16 21/4 36% 47% i6 32�i 14 a i% 13 12 14 19 2'f 421fz 55 fis 18 38 16 la 1 Vs 4 15 21 2a/ 5£13/8 6T% 18- 45 16314 1Y 14 15 WEIGHTS -- POUNDS 16 SIZE 21/z1 3 1 3112, 4 1 6 1 6 1 8 1 10 1 12 1 14 FIG.68 1 51 1 701 77 1109 11261 180 314` 441 610 890 17 F =DIA.OF HANDWHEEL H = NO.OF BOLTS 18 WHEN SPECIFIED J=DIA.OF BOLT B G= NUMBER OF TURNS:TO OPEN 19 BODY MARKING BONNET MARKING 26 SIZE UL YEAR YEAR 4FM►175 W \ KENNEDY YOKES ARE BOLTED ON IN SIZES LARGER THAN 4 INCH;4 INCH AND 22 BELOW—THE YOKES ARE CAST INTEGRAL WITH BONNET: A 125 M.AMERICAN STANDARD END FLANGE DRILLING. KENNEDY VALVE �- - - Division of ITT Grinnell Valve Co., Inc. POTTER ELECTRIC SIGNAL CO. OSYSU=A 2081 Craig Road • P.O. Box 28480 St. Louis, Mo.63146 • (314)878-4321 Toll-Free (800)325-3936 OUTSIDE SCREW AND YOKE TWX: 9107640909 VALVE SWITCH CHARACTERISTICS U.L. LISTED & F.M. APPROVED CONTACT RATINGS: OSYSU-A1 —One set of S.P.D.T. (Form C) OSYSU-A2 —Two sets of S.f .D.T. (Form C) 15 A @ 125/250 WAC 0.50 A @ 125 VDC 0.25 A @ 250 VDC 4k DIMENSIONS: 6.1"L x 2.3"W x 8.3"H See Fig. 2 15.5cm.L x 5.7cm.W x 21.Ocm.H WEIGHT: 2 lb. .9kg ENCLOSURE:Cover: Die-cast Aluminum Finished — Red Spatter Enamel Base: Formed Steel All parts plated to resist corrosion. COVER TAMPER:Mechanically Activated by cover removal. ENVIRONMENTAL LIMITATIONS: -40°F/+140°F OSYSU-A1 Stk. No. 1010102 OSYSU-A2 Stk. No. 1010202 The OSYSU-A is used to monitor the open position of an TYPICAL ELECTRICAL CONNECTIONS OS&Y(outside screw&yoke)type gate valve.This device is TYP.SWITCH ACTION available in two models;the OSYSU-A1, containing one set coM.r �(*N.0. of S.P.D.T. (Form C)contacts and OSYSU-A2,containing two ALARM— 0 N•C• sets of S.P.D.T. (Form C)contacts.These switches mount con- LOCAL AUDIBLE / CONTROL PANEL veniently to most OS&Y valves ranging in size from '/2" to CoM. N.O. 12". (For explosion proof requirements see model OSYS-U- TRANSFORMER AUDIBLE EX, Bulletin 705) OR BATTERY I N.C. DEVICE TAMPER RESISTANT TO N.o. CROSS CIRCUIT 1 END OF Removing the cover causes the switches to operate. Either FROM COM-1V,0LINE switch on the OSYSU-.A2 may be disconnected from the PANEL NC RESISTOR tamper action by removing the tamper action tab or Screw N.0. associated with that particular switch. (SEE PAGE 2) COM. TRANFORMER AUDIBLE WARNING OR BATTERY I N.C. DEVICE DISABLING THE TAMPER ACTION OF THE TO l NO. SWITCH ON THE OSYSU-A1 OR BOTH SWITCHES OPEN CIRCUIT_! O END OF LIN ON THE OSYSU-A2 WILL VOID UNDERWRITERS FROM COM. RESISTOR PANEL N.C. LABORATORIES' LISTING AND F.M APPROVAL. LOCAL AUDIBLE / REMOTE TRANSMITTER N.O. COM. SERVICE USE: TRANSFORMER aA DEVICE E r� Central Station NFPA-71 OR BATTERY I N.C. Local NFPA-72A I NO. Auxiliary NFPA-72B coM 0 FROM N.C. Remote Station NFPA-72C TRANSMITTER Proprietary NFPA-72D FIGURE 1 DWG. 5400655-15A 7-84 BULLETIN 724 1 OF 4 OSYSU-A TAMPER ACTION ADJUSTING SCREWS OR TABS TO DISABLE TAMPER ACTION OF EITHER SWITCH, REMOVE �•• ADJUSTING SCREW OR TAB COVER TAMPER ASSOCIATED WITH THAT SWITCH. ADJUSTING SCREWS: DO NOT ADJUST GROUNDING FACTORY SET SCREWS SCREW 1 3.03" 4.75'\ - 4.91" 2.25" 6.10 �\ 8.25'1 NOTE: DISABLING TAMPER ACTION OF SWITCH ON THE OSYSU-A I OR BOTH SWITCHES ON THE OSYSU-A2 WILL VOID UNDER- WRITERS LABORATORIES' LISTING AND F.M. APPROVAL. FIGURE 2 DWG. 5400724-30 BULLETIN 724 2 OF 4 7-84 OSYSU-A SMALL VALVE INSTALLATION - 1/2" thru 2 1/2" SIZES 1/2" THRU I-1/2" VALVES USE SMALL J-BOLTS. J-BOLTS MOUNT ON OUT- SIDE OF YOKE 'C 2" VALVES USE LARGE J-BOLTS. J-BOLTS MOUNT ON OUT- _ j SIDE OF YOKE. I e 2- 1/2" VALVES USE LARGE J-BOLTS. J-BOLTS MOUNT ON IN- SIDE OF YOKE. n I FIGURE 3 DWG. 5400724-31 SMALL VALVE INSTALLATION 7. Mount the OSYS.UA loosely with the trip rod centered in groove and perpendicular to base. 1. Remove and discard "C" washer and roller from the trip 8. Final adjustment is made by sliding OSYSUA laterally rod. across the yoke so that switches are not activated with the 2. With the valve in the FULL OPEN position, locate the trip rod seated in the valve stem groove and that the OSYSUA across the valve yoke so that the trip rod lays switches activate when the trip rod moves out of the against the non-threaded portion of the valve stem. groove. (Cover must,be on or cover tamper activator must 3. Mount the OSYSUA loosely with the small pair of J-bolts be held down while making adjustment.) supplied, so that the trip rod is held perpendicular to the 9. Tighten the mounting nuts. Check to insure that the rod base of the OSYSUA. (Use large J-bolts on 2" and 2 1/2" moves out of the groove easily and that the switches valve.) activate within one turn when the valve is operated from 4. Mark the valve stem at the center of the trip rod. the FULL OPEN towards the CLOSED position. 5. Remove the OSYSUA. File a 3/32" deep groove centered 10. Excess J-bolt length may be cut off. on the mark on the valve stem utilizing a 1/4" diameter non-tapered file. Round and smooth the edges of the groove to prevent damage to the valve packing and to NOTE: CLOSE THE VALVE FULLY TO DETER- allow the trip rod to move easily in and out of the groove MINE THAT THE STEM THREADS DO NOT as the valve is operated. ACTIVATE THE SWITCH. THE SWITCH BEING 6. Excess trip rod length extending beyond the valve stem ACTIVATED BY THE STEM THREADS COULD may be,cut off. RESULT IN A FALSE VALVE OPEN INDICATION. 7-84 BULLETIN 724 3 OF 4 OSYSU-A LARGE VALVE INSTALLATION - 3" thru 12" SIZES 3" THRU 12" VALVES USE LARGE J-BOLTS. J-BOLTS MOUNT ON INSIDE OF YOKE. i 1 o FIGURE 4 DWG. 5400724-32 LARGE VALVE INSTALLATION 6. Final adjustment is made by sliding OSYSUA laterally across the yoke so that switches are not activated with the 1. With the valve in the FULL OPEN position, locate the trip rod seated in the valve stem groove and that the OSYSUA across the valve yoke so that the trip rod lays switches activate when the trip rod moves out of the against the non-threaded portion of the valve stem. groove. (Cover must be on or cover tamper activator must 2. Mount the OSYSUA loosely with the large pair of J-bolts be held down while making adjustment.) supplied so that the trip rod is held perpendicular to the 7. Tighten the mounting nuts. Check to insure that the rod base of the OSYSU-A moves out of the groove easily and that the switches 3. Mark the valve stem at the center of the trip rod. activate within two turns when the valve is operated from 4. Remove the OSYSU A File a 1/8" deep groove centered on the FULL OPEN towards the CLOSED position. the mark of the valve stem utilizing a 3/8" diameter round 8. Excess J-bolt length may be cut off. file. Round and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to NOTE: CLOSE THE VALVE FULLY TO DETER- move easily in and out of the groove as the valve is MINE THAT THE STEM THREADS DO NOT operated. ACTIVATE THE SWITCH. THE SWITCH BEING 5. Mount the OSYSUA loosely with the trip rod centered in ACTIVATED BY THE STEM THREADS COULD groove and perpendicular to base. RESULT IN A FALSE VALVE OPEN INDICATION. BULLETIN 724 4 OF 4 7-84 PRINTED IN USA SERIES 40 BELLS wheeJock & STROBE BELLS THE SIGNAL SOURCES"' Wheelock's Series 40 bells provide the durable oper- ation and dependable performance required for life safety alarm systems. A complete range of single 10-INCH BELL stroke or vibrating models is offered in 4", 6" and 10" s sizes for AC or DC operation in indoor or outdoor in- stallations. All models provide high sound output with low power consumption. Unique strobe bell combina- tions are also available for effective audible and visual signaling. The strobe bell models mount directly to re- cessed 4" square backboxes and can be surface mounted to Wheelock's SB surface backbox. All models are provided with screw terminal inputs for secure in- _ out field wiring. Features � • UL Listed for Fire Protective Service. • High sound output with low current draw. • Complete range of single stroke and vibrating models with choice of shell sizes and input voltages. P 9 • Unique strobe bell models for combined audible and visual signaling. • Semi-flush mounting to standard 4" square back- boxes or surface mounting to Wheelock's surface ' backboxes. • Polarized for supervision of alarm lines with screw terminal inputs for fast and secure in-out field wiring. 4-INCH • Attractive red textured finish to enhance appearance 6-INCH and durability. STROBE BELL Specifications The alarm signals shall be Wheelock Series 40 Bells or approved equal. They shall be UL Listed for Fire Protective Service with models for single stroke or vibrating operation and optional steel shells from 4"to 10" diameter. Sound output at 10 feet shall range up to 74 dBA for single stroke models and up to 88 dBA for vibrating models. The bells shall semi-flush mount to standard 4" square backboxes or surface mount to Wheelock's indoor BB backbox or outdoor WBB backbox. Strobe bell models shall include an integral flashing strobe light with white polycarbonate lens and red FIRE lettering. The strobes shall produce 8000 peak candlepower at approximately one flash per second and shall be capable of operating independently or in parallel with the bells. The strobe bells shall semi-flush mount to standard 4" square backboxes or surface mount to Wheelock's SB backbox. All bell and strobe bell models shall be polarized for line supervision and shall have screw terminals for in-out field wiring. Rated input voltage for all DC models shall range from 18-31.2 VDC or 9-15.6 VDC. The finish on all models shall be textured red enamel. WHEELOCK, INC. •273 BRANCHPORT AVENUE• LONG BRANCH, N. J. 07740•(201) 222-6880 Ordering Information Model Shell Input Input dBA @ Mounting Number Size Voltage Current 10 feet Wiring Options Approvals 46T-G4-12-R 4" 9-15.6 VDC 0.125 84 46T-G4-24-R 4" 18-31.2 VDC 0.063 84 DC VIBRATING 46T-G6-12-R 6" 9-15.6 VDC 0.125 85 BELLS 46T-G6-24-R 6" 18-31.2 VDC 0.063 85 46T-1310-12-13 10" 9-15.6 VDC 0.125 87 46T-G10-24-R 10" 18-31.2 VDC 0.063 87 43T-G4-24-R 4" 24VAC 0.410 85 43T-G4-115-R 4" 115VAC 0.085 85 UL, FM, AC VIBRATING 43T-G6-24-R 6" 24VAC 0.410 86 Fig. 1 A,B,C,D CSA, CFM, BELLS 43T-G6-115-R 6" 115VAC 0.085 86 ULC, BSA 43T-G10-24-13 10" 24VAC 0.410 88 43T-G10-115-R 10" 115VAC 0.085 88 42PT-G6-12-R 6" 9-15.6 VDC 0.750 72 DC SINGLE 42PT-G6-24-R 6" 18-31.2 VDC 0.380 72 STROKE BELLS 42PT-G10-12-R 10" 9-15.6 VDC 0.750 74 42PT-G10-24-R 10" 18-31.2 VDC 0.380 74 Bell Strobe Peak Model Shell Input Input dBA @ Input Input Candle- Mounting Number Size Voltage Current 10 feet Voltage Current power Wiring Options Approvals 46T-G6-12-WS-12-HF-R 6" 9-15.6 VDC 0.125 85 9-15.6 VDC 0.084 8000 DC VIBRATING 46T-G6-24-WS-24-HF-R 6" 18-31.2 VDC 0.063 85 18-31.2 VDC 0.042 8000 UL, STROBE BELLS 46T-G10-12-WS-12-HF-R 10" 9-15.6 VDC 0.125 87 9-15.6 VDC 0.084 8000 Figs. 2, 3 E,F BSA 46T-G10-24-WS-24-HF-R 10" 18-31.2 VDC 1 0.063 87 18-31.2 VDC 0.042 8000 NOTES: 1.Typical dBA at 10 feet is measured in an anechoic chamber. 2. All bell models are optionally available with input leads rather than screw terminals. For lead versions delete "T"from model number(e.g., 46-G6-24-R). 3. Each bell mechanism is adjusted to operate only with the shell provided. Do not mix shells and mechanisms during installation. 4. DC vibrating bells have an in-rush current of approximately 2 times rated current during initial turn-on. 5.Strobe bell models �•� include RFI suppression to minimize induced noise on the alarm lines. 6. Approvals: UL = Underwriters Laboratories, ULC = Underwriters Laboratories of Canada, CFM = State of California Fire Marshall, FM = Factory Mutual, CSA = Canadian Standards Association, BSA = New York City Bureau of Standards and Appeals. Mounting Options (Mounting plates and backboxes ordered separately—specify color) Wiring A SEMI-FLUSH B SURFACE C CONCEALED Fig. 1 (ALL BELL MODELS) CONDUIT BELL — I OStandard BB _ ND PrecdingBellFACP o EOL Fig. 2 (BELL AND STROBE OPERATE IN PARALLEL) '' BELL STROBE SFP 4"square + - ® + - backbox AP __GNQ_ D OUTDOOR E SEMI-FLUSH F SURFACE P,eeed;eg Ren (STROBE BELLS) (STROBE BELLS) o`'FACPe" BtrEL`Bell _ Fig. 3 (BELL AND STROBE OPERATE INDEPENDENTLY) _ BELL __ STROBE —GPA— � ti i Weceding Nen Ben Ben Standard "NP WBB4' square { B�roUe eg $�febe backbox SB gr FAGP g�ENL WHEELOCK, INC. •273 BRANCHPORT AVENUE• LONG BRANCH, N. J. 07740•(201)222-6880 S0600-385 Printed in U.S.A. TED CHECK VALVES UNl SWING CHECK 200 lbs.WOG 100% Hydrostatic Tested Screwed Ends Replaceable Rubber Disc (Not recommended for steam) Sizes: 1/4" - 2" B VIEW 99S ,-,*N Size 1/4" 3/8" 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" A 1 57/64" 1 57/64" 2 9/64" 2 33/64" 3 1/32" 3 29/64" 3 13/16" 4 7/16" B 1 7/32" 1 7/32" 1 9/32" 1 17/32" 2 1/16" 2 13/64" 2 31/64" 2 55/64" Ship Wt. Obs.) .45 .45 .58 .81 1.22 1.81 2.41 3.42 Quan. Per Ctn. 12 12 12 12 6 6 4 4 125 lbs.WSP 200 lbs.WOG 100% Hydrostatic Tested Screwed Ends Teflon* Disc Sizes: 1/4" - 2" 99T For Replacement Seat Rings See Page 48 13 bronze butftrball brflY valves FOR FIRE PROTECTION SPRINKLER SYSTEMS a: And other slow close applications where water hammer is a concern B B-SC 1 O0 Slow close valve • Bronze body, threaded ends • Stainless steel disc and stem • Sizes 1" through 21/2" a Pressure 29" Hg vacuum to 175 psi Slow close operator Compact, lightweight manual operator has scotch yoke design & visual position indicator. Close coupled for positive direct drive. Economical alternative to Bronze O S & Y gate valves. One operator fits all sizes. r r ApprovedL Listed 41/2„ For use with fire protection sprinkler systems (� — I Approved by the New York City Board of Stds. &Appeals j under Calendar No. 996-81-SM. Rp or+ SIZE 1 11/4 11/2 2 21/2 B A 21/6 25/6 27/831/4 41/6 U B 375/16 49/32 417/32 5 51/4 c _—+ _ C 19/16 11516 23/16 23/4 35/16 D 123/32 21/8 23/8 31/16 31/2 Cv 1 43 1 85 1 12 1 180 180 (The Cv Factor is defined as the flow coefficient for valves,expressing the flow LD� �A rate in gallons per minute at 60°F. water with 1.0 psi pressure drop across valve.) SUPERVISORY SWITCH KIT These Supervisory Control Kits are for mounting on top of the operator of a BB-SC100 Slow Close Valve. The conver- sion from a BB-SC100 Slow Close to a Supervised Valve BB-SCS is simple and takes only a couple of minutes. Assembly instructions are provided with each switch. MODEL BB-SCK01 (One Micro Switch) MODEL BB-SCK02 (Two Micro Switches) r Approved W t� � Listed For use with fire protection sprinkler systems Approved by the New York City Board of Stds. & Appeals under Calendar No. 996-81-SM. STANDARD ' i FIRE z WEST 4�r. A SINGLE CLAPPER SIAMESE I No. S201D Single Clapper 2-Way Straight Siamese Inlet. Ductile iron. C Branded: "Auto Spkr". Finish: Painted red with brass swivels. Size: 4" x 21/2 x 21/: Specify: Thread. ; L N7 E S201D 4 X Z'/2 X Z'/2 5'I4 9314 71/2 No. S2020 Single Clapper 2-Way 900 Siamese Inlet. Ductile Iron. A Branded: "Auto Spkr". Finish: Painted red with brass swivels. Size: 4" x 21/2 x 2'/2'' lot ie 52020 4 x 1/2x 2'/2 87, 9,/e _., DOUBLE CLAPPER SIAMESE No. S132 Double Clapper 2-Way Straight Siamese A Inlet, cast brass. Branded: "Standpipe" or "Auto Spkr". Finish: Rough brass. Optional: Polished, Chrome plated rough or polished. 4 Sizes: 4" or 6" x 21/2" x 2'/z 4" or 6" x 3" x 3". e Specify: Size, thread, and branding. No. S133 Double Clapper 2-Way 900 Siamese Inlet, S132 cast brass. Same as S132 above except 900 instead of straight. D E 4 x 21/2 x 21/2 9% 1 Z'/4 113/ 9% 71/4 6 x %x 2'h 101/4 113/1 113/0 103/4 71/4 4 x 3 x 3 10 12'h 121/2 10% 71/2 L C *6x3x3 10% 121/2 121/4 101% 7V4 'Listed by Underwriters Laboratories S133 No. S279 Double Clapper 2-Way 450 Siamese Inlet, cast brass. U/L Listed. A Branded: `'Standpipe" or "Auto Spkr Finish: Rough Brass. Optional: Polished, Chrome Plated Rough or Polished. ..:=ar C Size: 4" x 2'/2" x 2'/2 a} j _ Specify: Branding and Thread. . -- = 4 x 2 1/2 x 2 y2 10% 121/2 83/0 $279 Page 33 DETECTOR-DOUBLE CHECK PRODUCTS INC. Valve Assembly Combination Sizers 3"9 4"1, 611 9 81", & 101" HERSEY MODEL DDC 11 WITH FULL USC AND UL APPROVALS Y: U CLASSIFIED BY S AS TO FRICTION LOSS AND BODY STRENGTH BACKFLOW PREVENTED WITH DETECTOR BYPASS DESCRIPTION The Hersey Model DDC II as a single unit offers the combined features of a detector check and a double check valve assembly for installation in fire lines. The mainline assembly consists of a Model 2 double check valve, which is listed by Underwriters' Laboratories. The bypass consists of an approved double check valve assembly, shutoff valves, testcocks and a meter with an unsealed register. Designed as a dual purpose unit, the Model DDC II will (1) detect leakage or unauthorized use of water from fire or automatic sprinkler systems as a detector check, and (2) will protect against ob- jectionable backflow contaminating the potable water system. A BEECO ( reduced pressure backflow preventer is recommended if a health hazard exists. ORDERING INFORMATION: SPECIFY METER REGISTRATION (CU FT OR GALS.) FEATURES: REPLACEABLE SEATS - LOW HEAD LOSS - REPAIRABLE IN-LINE-RUGGED CONSTRUCTION EASILY TESTED. OS+Y GATES ARE OFFERED AS A STANDARD FEATURE WITH A DDC 16. BODY CAST IRON WORKING PARTS BRONZE AND STAINLESS STEEL SPRINGS STAINLESS STEEL VALVE DISCS SILICONE RUBBER MAXIMUM WORKING PRESSURE 175 PSI HYDROSTATIC TEST PRESSURE 3..50 PSI-(MAINLINE ONLY) FLOW CHARTS 0 50 100 150 200 250 300 350 400 450 500 0 100 200 300 400 Soo 600 700 800 900 1000 12 72 12 12 M MRF 10 3, i0 10 10 ,F 3" 4 a 8If 8 8 w 8 W Q Q � 6 ¢ n a 4" 0 4 4 y 4 a o o J J 2 2 2 2 0 11 1 1 0 0 0 50 100 150 200 250 300 350 400 450 500 0 100 200 300 400 500 600 700 800 900 1000 RATE OF FLOW U.S.G.P.M. RATE OF FLOW U.S.G.P.M. 0 500 1000 1500 2000 0 500 1000 1500 2000 2500 12 12 12 1 12 MRF MRF /0 10 _10 10 N N it a w 8 8 W 8 8 � 1 a 8/' a 8 6 ■O" 01 8 8 01 O 0 4 N 4 4 N 4 O O J J 2 2 2 2 0 go 0 0500 1000 1500 - 2000 0 500 1000 1500 2000 2500 RATE OF FLOW-U.S.G.P.M. - RATE OF FLOW-U.S.G.P.M. III II II LI , E OPEN 0 0 0 0 0 0 9 0 0 1 L— A .'--D-TC DIMENSIONS: SIZE 3"x 3/411 491X 3/471 619X 3/411 899X 3/471 10"X 3/417 END DETAIL FLGD. FLGD. FLGD. FLGD. FLGD. MAX. GPM 320 500 1000 1600 2300 A 40 461/2 62 751/2 88 B 4 411116 53/4 7 81/2 C 41/8 411116 63116 8 318 103116 D 95/8 13 141/4 151/4 161/4 OS+Y GATES) E OPEN 181/4 21 718 293/4 40 481/2 NET WEIGHT 290 466 817 1546 2522 GROSS WEIGHT 370 561 969 1771 2807 TEST COCK SIZE 1/2 1/2 13/4 3/4 3/4 SALES OFFICES py SOUTHEAST— 2131 Kingston Court, S.E., Suite 102, Marietta, GA 30067 (404) 952-4424NEW ENGLAND — 250 Elm St., Dedham, MA 02026-9115 (617) 326-9400 PRODUCT . NORTHEAST —320 Braen Ave., Wyckoff, NJ 07481 (201) 445-0373 Water Meter & Controls Group MIDWEST — 1025 Criss Circle, Elk Grove Village, IL 60007 (312) 439-7700 250 Elm Street, Dedham, MA WESTERN — 7240 East Slauson Ave., Los Angeles, CA 90040 (213) 722-6870 02026-9115 U.S.A. Copynght< 1985 Hersey Products Inc,oaa❑am Massachusetts 02025 v S A Printed in U S A- 5M/9/85/TD (617)326-9400 Telex 92-4352 February 1985 20E-12-2 WFD and WFD-10 Series Waterflow Detectors � NOTIFI ER@ (for large ferrous pipe sprinkler systems) LISTfNGS ��� O Fire Marl 7770-028:32 GENERAL Vane-type waterflow detectors detect the flow of water in wetpipe sprinkler pipes and signal fire detection and control systems or auxiliary indicators when flow occurs.Water flowing in the pipe deflects the vane of the detector, causing a contact closure signal. This initiating signal will trigger the sounding of an alarm, either general/zone alarm or auxiliary Indication. The WFD and WFD-10 Series detectors are used 6�4 in ferrous(steel or black iron)pipe sprinkler systems, , u 2" lines and larger, Do not use them in copper pipe I '. systems! (Use WFD-1/11/2 or WFDC-1/11/2 detectors in "T pipe smaller than 2",either ferrous,copper,or pias- q tic. See catalog nos. 20E-12-1 and 20E-12-3.) 4 o FEATURES J j ' � 4, � For wetpipe sprinkler systems that use ferrous (steel or black iron) piping Models available for both Schedule 40 and Schedule 10 , pipe (Schedule 40 models adaptable for Schedule 80 �. :; _ :Q _ �,_ i ,., pipe) (WFD-2 shown) Adjustable pneumatic delay prevents false alarms due to water surges; serviceable without draining pipe APPLICATIONS ^� Requires no power io operate sensing mechanism Steel u-bolts provide secure mounting WFDs are used in wetpipe sprinkler systems to Impact resistant cover protects mechanism signal waterflow of 4 to 10 gpm. The flow could be Heavy duty aluminum saddles due to the opening of one or more sprinkle heads or test valves,or it could be due to leakage or rupture of OPERATION the piping. When water flows in the pipe, it deflects the By the appropriate choice of installation sites, vane, which operates a linkage to release the pneu- the WFDs can be used to signal general flow matic delay shaft. The stop on the shaft in turn (installed on mains) or flow by zones (installed on releases the switch levers at a rate determined by the branch lines). Either horizontal or vertical pipes can presetting of the pneumatic delay mechanism.When be utilized. the shaft and its stops have pulled far enough away, Common usages of WFDs include operating a the spring operated switch levers actuate the two bell or horn at the riser and signaling a control panel SPDT switches. The switches have both NO and NC or master box. terminals. If the WFDs are used at the upper limits of their When, water stops flowing,the vane is no longer temperature ranges,especially at a 100%duty cycle, deflected and a spring draws the actuator arm of the their working life may be significantly shortened. linkage back against the stops on the pneumatic Use these detectors on steel pipe only.They will delay shaft, closing the switch levers and returning not fit or function correctly on copper or plastic pipe. the device to its normal condition. The pneumatic delay mechanism is adjustable CAUTION across a range of 0 to 70 seconds:It incorporates an Do not use vane-type waterflow detec- automatic, noncumulative reset to accommodate a tors in the following: sequence of surges without acquiring an accumu- drypipe sprinkler systems, fated delay greater or less than the preset value. As deluge systems, and shipped,the adjustment dial is set for a delay of 20-30 pre-action systems. seconds; but any value within the range can be The vane and linkage of the WFD can be selected in the field. damaged by the sudden rush of water The two switches allow both an alarm and auxil- when the control valve opens. Use a iary circuit to be connected to a single detector,each pressure actuated detector on such sys- isolated from the other. tems instead. the hole to prevent leakage and securing the detec- tor in place. Loop wiring is connected to the switch or switches as appropriate. Tamper resistant screws hold the cover in place over the mechanism to pro- �..� tect the device. #10 Spanner SPECIFICATIONS Cover Wrench (Provided) �I� � Contact Ratings .........................-.....................7.5 A @ 125 Vac \�- 0.25 A @ 125 Vdc or less Tamper-resistant Dual Switches Triggering Threshold Security Screw Bandwidth (flow rate) 4-10 gpm, min. Pneumatic Delay Conduit Maximum Velocity of Waterflow 15 fps y - Entrance Static Pressure Rating.._..............................._................. 250 psi Dela Overall Dimensions, Adjustment Dial \' j\\ Nut installed (HWD) .................. (P.D.+5.5") x (P.D.+3.0") x 6.7" f (P.D.+14.0 cm) x (P.D.+7.6 cm) x 17.0 cm Wiring Major Component Materials ....................aluminum saddle, \� Label steel u-bolt,cast aluminum mounting plate,flame retardant Mounting Plate polycarbonate cover, polyethylene vane Pipe Saddle I� Operating Temperature Ranges Plastic Vane Ambient Air ----------------------------32 OF -120 OF (0°C -49°C) System Water 32 OF - 100 OF (0°C -43 °C) 0-ring I Compatible Pipe -------------------------------------------- steel water pipe, Schedule 10,40,and 80 Shipping Weight--------------------------------------------varies,4 lbs.-7 lbs. according to size ORDERING INFORMATION WFD Series Waterflow Detectors For Schedule 40 (or 80) steel pipe — �ofA WFD-2.......................................................................546-7020 WFD-21/2-------------------------------------------------------------.------546-7025 I WFD-3 ..._.---546-7030 WFD-4------------------------------------------------------------------------546-7040 WFD-5 546-7050 U-bolt WFD-6 - -- -- - - -- 546-7060 WFD-8------------------------------------------------------------------------546-7080 WFD-10 Series Waterflow Detectors For Schedule 10 steel pipe only— NOTE: Area inside pipe(one pipe diameter each side of hole WFD-10-2 ................................................................546-7721 center—shown by dashed lines) must be free of scale and WFD-10-21/2..............................................................546-7722 obstructions. WFD-10-3 ----------------------------------------------------------------546-7723 WFD-10-31/2 - . ..........................---- 546-7724 INSTALLATION WFD-10-4 ---------------- 546-7725 WFD-10-5 ----------------------------------------------------------------546-7726 The details of proper location and the method of WFD-10-6* ----------------------------------------------------------....546-7727 installing the detector on the pipe are contained in WFD-10-8t ......................-....-................................546-7728 the installation sheet packed with each detector. Accessories — Briefly, a properly centered hole is made in the Optional Tamperswitch Kit ...546-6000 drained pipe. The edges of the vane are squeezed replacement#10 spanner wrench together sufficiently to allow it to be inserted (one each supplied with above)........-_---.....109-7207 through the hole as the detector is set in place on the pipe. The vane is trimmed first before insertion for *nominal wall thickness—0.134"min. Schedule 80 pipe. A u-bolt clamps the saddle of the tnominal wall thickness—0.188"min. detector against the pipe, sealing the o-ring around ns ENGINEERING SPECIFICATIONS Vane-type waterflow detectors shall be installed on the sprinkler system piping as designed on the drawings and/or as specified herein. Detectors shall mount on any clear span of pipe of the appropriate nominal size,either a vertical or horizontal run, up to within 10 pipe diameters of any fitting or valve which changes or controls direction,diameter,or rate of flow.Detectors shall have sensitivity sufficient to detect and signal any flow of water equal to or greater than the discharge of one sprinkler head.Detectors shall have a minimum static pressure rating of 250 psi.A pneumatic delay mechanism shall be incorporated in the detectors that shall cover a field adjustable range of 0 to 70 seconds to prevent false alarms due to water surges within the sprinkler system.Delay shall be noncumulative to prevent any sequence of surges from acquiring an accumulated delay period greater or less than that set on the delay adjustment dial.The actuation mechanism of the detectors shall include an inert plastic vane placed in the waterway of the piping and actuating a mechanical linkage operating two separate SPDT electrical switches simultaneously,each having three terminals(common,normally open,and normally closed)so that two isolated circuits of loop wiring can be connected to each detector,each circuit being provided either a contact closure signal or disruption of continuity upon actuation and utilized as designated on the drawings and/or as specified herein.A wiring entrance for standard fittings of commonly used electrical wiring conduit shall be provided on the detectors.The detectors shall be listed by Underwriters Laboratories and Factory Mutual System. Bulletin 111 G ® Model G Recessed HIM11abi Automatic Sprinkler The Most compact, • - Attractive and Easily Installed Sprinkler Ever Designed. _ ' Features 1. 11/2"Total adjustment provided by adjustable inlet versions 2. 1/2'Total adjustment provided by economical standard inlet version 3. Adjustable inlet version available with #` either 1" NPT male or female threads eliminating costly reducing coupling r1 4. Small diameter escutcheon ` �. 5. Available in brass, chrome or white finish 6. Multiple orifice sizes for design flexibility The Model G Recessed Sprinkler's threaded two- piece construction makes initial field installation a very 7. Suitable for non-residential and easy task. It also allows ceiling panels to be removed residential occupancies alike without shutting down the sprinkler protection thus facili- tating maintenance of above ceiling services.The adjust- able version with its one inch inlet and one and one half & Underwriters' Laboratories Of Canada. inch adjustment eliminates both the normally required Approved by Factory Mutual Research reducing coupling and the need to accurately cut drop Corporation, NYC BS&A No. 587-75-SA. nipples.This sprinkler can be adjusted after the ceiling is in place and even while the system is pressurized eliminating the final corrections to pipe hangers or ceilings Today's modem buildings demand that a sprinkler not that might otherwise be required. only provide the best fire protection but also achieve an Sprinkler is the heart The Reliable Model G Automatic S attractive appearance. Reliable's Model G Recessed p Sprinkler, like Reliable's Model F Recessed Sprinkler of the Recessed Sprinkler.This sprinkler utilizes the center meets both criteria. It combines the fire fighting capability strut solder in compression principle of construction.The of a proven sprinkler with the smallest practicable recess- fusible alloy, captured in the cylinder of a small Solder ing unit. Its small profile does not disrupt the overhead Capsule by a stainless steel ball,acts as the trigger of the aesthetics, and yet one vertical glance upward gives a sprinkler.When the fusible alloy melts,the sprinklers oper- visual assurance of the finest in fire protection, an auto- ating parts spring free from the sprinkler clearing the matic sprinkler system. waterway and allowing the deflector to distribute the dis- charging water. The Reliable Automatic Sprinkler Co.,Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Sprinkler Maximum Ceiling Standard Finishes* Classification Rating Temperature Frame Sprinkler Escutcheon °F °C °F oC Color Bronze Brass Ordinary 135 57 100 38 Black Bronze White Ordinary 165 74 100 38 Uncolored Chrome Bright Chrome Bright Intermediate 212 100 150 66 White Chrome Bright Chrome Dull Chrome Bright White *Special Finishes Upon Request K Factor Sprinkler Inlet Total Adjustment* Nominal Orifice U.S. Metric Thread Approvals Non Adjustable 1/2" 112" 5.62 81.0 1/2"NPT 1,2,3,4 Non Adjustable 1/2" 7/16" 4.24 61.0 1/2"NPT 1,3,4 Non Adjustable 1/2" 3/8" 2.82 40.6 1/2"NPT 1,3,4 Non Adjustable 1/2' 10 mm 4.10 59.1 10 mm BSP Non Adjustable 1/2" 17/32" 7.96 114.7 1/2"NPT 1,3 Adjustable 1112" 1/2" 5.53 79.7 1"NPT Male 1,2,3,4 or Female Adjustable 11/2" 7/16" 4.24 61.0 1"NPT Male 1,3,4 or Female Adjustable 11/2" 3/8" 2.72 39.2 1"NPT Male 1,3,4 or Female *Sprinkler Escutcheon provides 1/2"of the Total Adjustment.Adjustable Inlets,when used,provide 1"of the Total Adjustment. Ordering Information Approval Organizations Specify 1. Underwriters Laboratories Inc. 1. Temperature Rating 5. Sprinkler Type: Either 2. Factory Mutual Research Corp. 2. Nominal Orifice Non-Adjustable Inlet(Fig. 1) (Light Hazard Occupancies) 3. Sprinkler Finish 1"Male Adjustable Inlet(Fig.2) 3. Underwriters'Laboratories of Canada 4. Escutcheon Finish 1"Female Adjustable Inlet(Fig.3) 4. N.Y.City BS&A No.587-75-SA *Add 5/16"for Pintle on 3/8"&7/16"Orifice. 1"System, 1"System Tee, e,or Elbow Drop Nipple ---�� -ly k --- 4Rr---;� � � �W 1.1 --- _ _ Note 1 �l�r -,.Note (55.5) �'1L- 1"NPT Male 23/is"Dia. Coupling 1"NPT Female Reducer 33/4"±3/4' 2�4"* �• Face of Fitting to Coupling 33/4'± 314' oa4na (70) Face of Ceiling Reducer Drop Nipple to Ceiling, 1/4 i Inlet Dimension Inlet Ceiling Dimension Max �— (44) 1"Max Sprinkler Adjustment 11'Max Sprinkler 1" oa4an Assembly Adjustment Cup Adjustment Ceiling Ceiling f Ceiling @NTT Assembly I.---3"Dia. Ceiling (76) T N T ' Ceiling j 9 �„ i_ _ 11z Dimensions in Parenthesis in Millimeters Escutcheon Max Adjustment + Escutcheon Max Adjustment 1/2"NPT Non-Adjustable Inlet 1"NPT Male-Adjustable Inlet 1"NPT Female-Adjustable Inlet Figure 1 Figure 2 Figure 3 M Product Description and Installation by hex flats on the coupling reducer as depicted in the The Reliable Model G Recessed Sprinkler has been de- figures—do not wrench on any other part of the sprinkler. signed with ease of installation in mind.A choice of three After the ceiling tiles have been cut and installed in place inlets with up to one inch adjustment coupled with the 112" (a 21/4'diameter hole is recommended),the sprinkler can escutcheon adjustment enables most systems to be in- be adjusted using the RC Concealed Wrench. When stalled using pre-cut drop nipples. The adjustment can using the wrench in this application,however,do not over- be accomplished after the ceiling installation and while torque beyond the adjustment stops. the system is pressurized thereby providing sprinkler pro- Fig.4 shows a 1/2' NPT non-adjustable inlet sprinkler, tection before construction is completed. with the attached sprinkler cup combination inserted into The Non-Adjustable inlet version(Fig.1)consists of the the special Reliable Model RC-Installation Wrench. This Reliable Model G Sprinkler with an attached cup re- wrench must be used.The wrenching pads of the sprin- cessed in the ceiling. A ceiling hole of 21/a" diameter is kler easily slip into the rectangular cut-outs of the wrench recommended. as the outside diameter locates the threaded cup.A 1/2' The Adjustable inlet version uses the same sprinkler as drive ratchet can then be used for installation and tighten- the Non-Adjustable inlet type except that 1" additional Ing i 5showstheremovalofthewrench.Careshouldbe adjustment is provided by a telescoping sprinkler inlet g section that threads in or out of a stationary Coupling taken during this procedure to avoid hitting the deflector Reducer(either 1"male or 1"female)as shown in figures 2 with the wrench. The wrench should be lowered until it or 3.The Sprinkler-Cup assembly comes attached to the clears the threaded cup,and then moved horizontally to inlet Coupling Reducer and is retained from separation clearthe sprinkler.The installation is completed bythread- past its maximum adjustment length by a snap ring.This ing the escutcheon on until it contacts the ceiling.To avoid combination is simply installed after the system drop nip- leaving smudge marks on the ceiling,the Reliable Model ple,elbow or tee has been"roughed"into the dimensions FEA Flush Sprinkler Escutcheon Wrench should be used. shown in figures 2 or 3.Wrenching means are provided See Bulletin 205 for details. Note: 1. Use hex wrench fiats on Coupling Reducer to tighten Adjustable Sprinkler into fittings. ,n Do not use RC Wrench for this purpose. ti r-y Figure 4 Figure 5 Reliable . . . For Complete Protection Reliable offers a wide selection of sprinkler components.Following are some of the many precision-made Reliable products that guard life-and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Supertrol electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices L-- • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms Pressure gauges • Electrical sprinkler alarm switches Identification signs • Water flow detectors Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Reliable Sprinkler Devices,protecting life and property for over 60 years,are approved by all fire insurance and government agencies,and are installed and serviced by Reliable's chain of representatives. Reliable representatives,located throughout the United States,Canada and foreign countries,have a life-time of experience and are as near as your telephone. Manufactured by The Reliable `�.. Himillabill Automatic Sprinkler Co.,Inc. 525 North MacQuesten Parkway Mount Vernon,New York 10552 (914)668-3470 (S)PRINTED IN U.S.A.12185 Bulletin 110H Model G ® Automatic Sprinklers -� Spray Upright, Spray Pendent and Conventional Product Description The Reliable Model G Automatic Sprinkler utilizes the center strut solder in compression principle of construc- tion. The fusible alloy is captured In the cylinder of the solder capsule by a stainless steel ball.When the fusible alloy melts,the ball moves into the cylinder allowing the cylinder to fall away from the sprinkler. When this hap- pens,the lever is released to spring free from the sprinkler so that all of the operating parts clear from the waterway allowing the deflector to distribute the discharging water. Except for the parts in the cylinder as mentioned above,the sprinkler components are made from copper based alloys for maximum corrosion protection. Lead Small orifice Conventional plated,wax coated or wax over lead plated sprinklers are Upright available for specially severe environments. Chrome (With Pintle plated sprinklers are available for decorative purposes. Screw) All sprinklers are individually hydrostatically tested. All sprinklers are identified as to their fusing point by markings that appear on several of the operating parts and by an identifying color that appears on the frame. Conventional—This deflector configuration is used pri- Sprinkler Types marily in those countries where the F O.C.installation rules Standard Upright—This deflector configuration is nor- have precedence.The sprinkler is designed to distribute mally used with exposed piping installations. Water is a portion of its water discharge upward against the ceiling distributed laterally and downward in a wide pattern ap- with the balance downward. It may be installed in either proximating a hemisphere which is completely and uni- the Upright or the Pendent position. Sprinklers with con- formly filled with water in the form of small drops or spray. ventional deflectors are available with orifice sizes corre- At a sprinkler height of 10 feet, a circular area of approxi- sponding to light, ordinary and extra-high hazard mately 20 feet in diameter is covered by the water dis- installations. charged at the minimum pressure. Application and Installation Standard Pendent—This deflector configuration is nor- Standard sprinklers are used in fixed fire protection sys- mally used where the space above the piping is not tems: Wet, Dry, Deluge or Preaction. Care must be exer- adequate or where a concealed piping installation is em- cised that the orifice sizes,temperature ratings,deflector ployed. The discharge characteristics of the Standard styles and sprinkler spacings are in accordance with the Pendent are virtually Identical to the Standard Upright as latest published standards of the National Fire Protection described above. Association or the approving authority having jurisdiction. Large and Small Orifice—By varying the orifice size,a The sprinklers must be installed with the Reliable Model large or small orifice sprinkler is created that will distribute D Sprinkler Wrench.Any other type of wrench may Jam- as much as 40%more water or 65%less water than the age the sprinkler. Installation and sale of automatic fire normal 112'orifice sprinkler.These sprinklers are identified sprinkler systems utilizing equipment manufactured by by the orifice size that is stamped in the base of the Reliable is performed by a world-wide network of install- sprinkler and by the pintle that extends from the deflec- ing distributors. Consult the Yellow Pages under"Sprin- I for—the exception is the Large Orifice Sprinkler with the klers-Automatic Fire",or write to us directly. 3/4"NPT inlet thread where the size of the Inlet is sufficient The approvals or listings of Reliable Automatic Sprin- I to classify this sprinkler as one having a larger than stan- klers by major approving organizations are shown in the dard orifice. tabulated list provided on the back of this bulletin. I 'Patent No.4,440,234 The Reliable Automatic Sprinkler Co.,Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Model G Installation Data pp Sprinkler Type uSK'F actor Metric SHeight r Approvals Standard—Upright(SSU)and Pendent(SSP) Deflectors Marked to Indicate Position '/z"Standard Orifice with 1/2"NPT(15 mm)Thread 5.62 81.0 27A"73 mm 1,2,3,4,5,6,7 7/16"Small Orifice(')with'h"NPT(15 mm)Thread 4.24 61.0 33/16' 1,3,7 -'6'Small Orifice(')with'/2"NPT(15 mm)Thread 2.82 40.6 33/16" 1,2,3,7 5/16"Small Orifice(')with 1/2"NPT(15 mm)Thread 1.98 28.5 33/16" 1,3,7 17/32"Large Orifice(')with 112"NPT(15 mm)Thread 7.96 114.7 33/16" 1,2,3,7 17/32"Large Orifice with 3/4"NPT Thread 8.20 118.2 221/32" - 1,2,3,7 20 mm XHH with 20 mm Thread 8.20 118.2 75.4 mm 4,5,6 10 mm XLH with 10 mm Thread 4.10 59.1 73 mm 4,5,6 Conventional—Installed in Upright or Pendent Position 10 mm XLH with 10 mm Thread 4.10 59.1 73 mm 5 15 mm Standard Orifice with 15 mm Thread 5.62 81.0 73 mm 4,5,6 20 mm XHH with 20 mm Thread 8.20 118.2 75.4 mm 4,5 (1) Identified by pintle extending above deflector,Sprinkler Height includes pintle extension Temperature Ratings Approval Organizations: Sprinkler Maximum Ceiling 1. Underwriters Laboratories, Inc. Classification Rating Temperature Frame* °F °c °F oc Color 2. Factory Mutual Research Corp. Ordinary 135 57 100 38 Black 3. Underwriters'Laboratories of Canada Ordinary 165 74 100 38 Uncolored 4. Fire Offices'Committee Intermediate 212 100 150 66 White 5. Pleniere Assemblee High 286 141 225 107 Blue 6. Verband der Sachversicherer *Frame Color does not apply to chrome plated sprinklers—Use sprinkler 7. N.Y City, B.S.and A. No.587-75-SA. rating as identified on operating parts as shown below. Finishes Natural Bronze —All Temp.ratings Deflector Bright Chrome Plated —All Temp.ratings e, (Upright) Satin Chrome Plated —All Temp.ratings Lead Plated —165°F,212°F&286°F ratings Strut(with Lever Corroproofed —165°F Clear Wax,212°F Brown Wax Temperature Corroproofed —165°F Clear Wax,212°F Brown Wax and Year $ Over Lead Plated Identification) E. Enameled —Subject to Acceptance by Authority having j Jurisdiction.Not Approved by Official Approval Organizations. Solder Capsule (with Temperature Maintenance and Year Sprinklers should be inspected regularly for any physical Identification) damage, dust, corrosion and paint(other than the ident- Frame ifying frame color). Cap Note:Never suspend any items(signs or decorations) from the sprinklers. All automatic sprinklers should be Inlet Threads replaced after 50 years of service or before if they become painted,corroded or otherwise damaged. Upright Once fused, automatic sprinklers cannot be reas- sembled and reused. New sprinklers of the same size, purpose. Use only the special sprinkler wrench provided type and temperature rating must be installed.A cabinet by the manufacturer for sprinkler removal and installation. of replacement sprinklers should be provided for this Any other type of wrench may damage the sprinkler. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Reliable Sprinkler Devices,protecting life and property for over 60 years,are approved by all fire insurance and government agencies,and are installed and serviced by Reliable's chain of representatives. Reliable representatives,located throughout the United States,Canada and foreign countries,have a life-time of experience and are as near as your telephone. Manufactured by The Reliable � Automatic Sprinkler Co.,Inc. Rellab' 525 North MacQuesten Parkway Mount Vernon,New York 10552 (914)668-3470 (S)PRINTED IN U.S.A.10185