Loading...
Report Fc,s3-o A- D JUL 1 b 2019 • � �pCil Y �7� �I��Rs:a ����� Bt ILDING I�I�,�ISICN SIEMENS 15201 NW Greenbrier Parkway Suite A-4 Beaverton,Oregon 97006 Phone: (503)207-1900 Fax:(503)207-1901 FIRE ALARM SUBMITTAL Washington Square 85C Bakery Submittal Version Date Siemens Job Number 44OP-265383 Issued for Review 07.09 2019 Siemens Project Manager Moses Frangopolous Siemens Project Engineer Garrick Youngberg,SET Unrestricted Proprietary document for approval only TABLE OF CONTENTS Unrestricted S I E E N S BILL OF MATERIALS & COMPONENT SPECIFICATIONS FIRE ALARM POWER SUPPLY BATTERY AND VOLTAGE DROP CALCULATIONS BILL OF MATERIALS SIEMENS FIRE ALARM SUBMITTAL Washington Square 85C Bakery Fire Alarm System Panel Components Item Model# Siemens Part# Quantity Color Mfg Description 1 E60H-24MCC-FW 9 White Wheelock Multi-Candela Speaker/Strobe-White,Ceiling Mount-High Fideli 2 STW 2 White Wheelock Exceder Multi-Candela Strobe-White,Wall Mount 3 TRI-R 500-896224 4 Siemens MXL Control Relay Module w/Monitor Point 4 STWC 2 Exceder Multi-Candela Strobe-White,Ceiling Mount 5 FP-11 500-095112 2 White Siemens MXL Smoke Detector-Photo 6 FDBZ492 S54319-822-A1 2 Grey Siemens Air Duct Housing 7 ST-50 500-649712 2 Grey Siemens Duct Detector Sample Tube,3'-0"to 5'-0"Duct Width 8 PS-8 1 Red Wheelock Wheelock Power Supply 8-Amp 9 12V-8AH* WKAl2-8F 2 Black Werker 8 Amp Hour Battery,12VDC* * Catalog Cut Sheets not available Unrestricted PROPRIETARY DOCUMENT FOR APPROVAL ONLY 7/10/2019 : ' Series E70 Speakers anCOO® d SpeR Notificationaker Strobes FIRE FIRE ; SERIES E70 - STROBE SERIES E70 SERIES E90 SERIES E90 SPEAKER STROBE SPEAKER Description Features The Wheelock Series E Low Profile Speakers and Speaker Strobes • Approvals include: UL Standard 1971, UL Standard 1480, are designed for high efficiency sound output, with dual voltage New York City(MEA),California State Fire Marshal(CSFM), (25/70 VRMS) capability and field selectable taps from 1/8 to 2 Factory Mutual(FM)and Chicago(BFP) See approvals by watts. The low profile design incorporates a speaker mounting plate model in Specifications and Ordering Information for faster and easier installation. Each model has a built-in level ADA/NFPA/ANSI compliant adjustment feature and an aesthetic two(2)screw grille cover. •The Series E Speaker Strobe models incorporate the Low Current • Complies with OSHA 29 Part 1910.165 draw Series RSS Strobes. • Wall mount models are available with Field Selectable Strobe options for wall mount models include 1575 or Wheelock Candela Settings of 15/30/75/110cd or 135/185cd,or 1575cd(Single Candela model)(Multi- patented MCW multi-candela strobe with field selectable candela Candela models), settings of 15/30/75/110cd or the high intensity MCWH strobe with • Ceiling mount models are available with field selectable - field selectable 135/185cd. candela settings of 15/30/75/95cd or 115/177cd (Multi- Ceiling mount models are available in Wheelock patented MCC candela models) multi-candela ceiling strobe with field selectable intensities of • Strobes produce 1 flash per second over the regulated 15/30/75/95cd or the high intensity MCCH strobe with field voltage range selectable 115/177cd. • 24 VDC with wide UL"Regulated Voltage" Series E Speakers and Speaker Strobes provide high audio usingfiltered DC or unfiltered VRMS input voltage output with clear audibility and are designed to meet the critical needs of the life safety industry for effective emergency voice • Synchronize using the Wheelock Sync Modules or panels communications, tone signaling and visible signaling to alert the with built-in Wheelock Patented Sync Protocol hearing impaired. • Field selectable taps for 25 or 70 VRMS operation from 1/8 The strobe portion of all Series E Speaker Strobes may be watt up to 2 watts synchronized when used in conjunction with the Wheelock DSM High efficiency for maximum at minimum Sync Modules,Wheelock Power Supplies or other manufacturers • wattage acrossy a design for frequency range of 400 to output at HZ panels incorporating the Wheelock Patented Sync Protocol. Wheelock synchronized strobes offer an easy way to comply with • Fast installation with IN/OUT screw terminals using#12 to ADA recommendations concerning photosensitive epilepsy. #18 AWG wires Series E Speaker Strobes are UL Listed for indoor use under Standard 1971 (Signaling Devices for the Hearing-Impaired)and Standard 1480(Speaker Appliances),and use a Xenon flashtube with solid state circuitry enclosed in a rugged Lexan® lens to provide maximum reliability for effective visual signaling. All inputs are supervised and employ IN/OUT wiring terminals for fast installation using#12 to#18 AWG wiring. Color options for the Series E Speakers and Speaker Strobes are red,white and nickel plated. ofil MEA " APPROVED S5391 151-92-E 7125-0785:152 7320-0785:134(Speaker) NOTE:All CAUTIONS and WARNINGS are identified by the symbol A.All warnings are printed in bold capital letters. • A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • "Regulated Voltage Range"is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology"Listed Voltage Range". Table 1: UL Max Current* E70 Strobe Current-Wall Mount E90 Strobe Current-Ceiling Mount E70/E90 Speaker 241575W 24MCW 24MCWH 24MCC 24MCCH Strobes 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 16-33 VDC 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 Table 2: E70/E90 UL Reverberant dBA @ 10 Feet** *UL max current rating is the maximum RMS current watts 1/8 1/4 1/2 1 2 within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at E Speaker 77 81 83 86 89 the minimum listed voltage(16v for 24v units). For E Speaker Strobe 76 80 82 85 88 audibles the max current is usually at the maximum **dBA ratings are based on testing under UL Standard 1480. listed voltage(33v for 24v units). For unfiltered FWR ratings,see installation instructions. Wiring Diagrams# SERIES E SPEAKER&STROBE OPERATE SERIES E SPEAKER STROBES SYNCHRONIZED INDEPENDENTLY(NON-SYNC OR SYNC) WITH MULTIPLF5 DSM MODULES FROMA ei•I-NA I Note: Figure PRECEDING +- + TON AaN Strobe NAC CIr.r Syr+c MEIN © © shows intercon- APPLIANCE APPLIANCE F �;� OR VOICE OREOLR vection to strobe Audible NACCir DSM#2 EVACUATION through sync PANEL TO NEXT A Strobe NACCir. '�Synt © © module. Speaker FROM + - - r——— ——— +STROBE ■ ?' P PRECEDING — —— - OR C !l STROBE SYNC - - —— EOLR I requires 2 MODULE, 1 r DSM#3 portion `t Audible NAC Cir POWER SUPPLY P —sim Sync © © separate conduc- OR Strobe NAC Cir. `I+ 1 4 tors to FACP. FACP 0 STROBE SPEAKER DSM Interconnecting wiring shown.Maximum of twenty(20) SERIES E SPEAKER STROBE APPLIANCES SERIES E SPEAKER STROBE APPLIANCES &RSS SYNCHRONIZED WITH DSM MODULE SINGLE STROBES SYNCHRONIZED WITH WHEELOCK POW- CLASS"A" DSM ER SUPPLIES PS Power Supplies STROBE _—t + / NAC SYNC E C\ CS CIRCUIT OUTPUTS EOLR OUT ee • �©�©O©7 F -CLASS 1-4 --� Q �t'L /�+IN1 /� ' Q •B /� '41— MINUS 1 A OR B C 2-CLASS /� /+AUDIBLE C ,A, ___I MINUS2 /' t©3©j F Co+IN 2 / STROBE /�+OUT 2 C NAC E \ go CIRCUIT RETURN Series PS Power Supplies For wiring information on the Wheelock power supplies, please refer to Data Sheet#S9100. B For detail using DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84905. Specifications and Ordering Information Strobe Sync w/ Model Model Model Agency Approvals Order Wall Ceiling DSM or Strobe Color Color Color Mounting Op- Model Code Mount Mount Wheelock Power Candela tions RED White Nickel UL MEA CSFM FM BFP Supplies E70-24MCW-FR 9022 X - X 15/30/75/110 X - - L,O,P,Q,R,U,Y X X X X X E70-24MCW-FW 9023 X - X 15/30/75/110 - X - L,O,P,Q,R,U,Y X X X X X E70-24MCW-FN 3099 X - X 15/30/75/110 - - X Q,U X X X X X E70-241575W-FR 7871 X - X 15(75 on Axis) X - - L,O,P,Q,R,U,Y X X - X X E70-241575W-FW 7876 X - X 15(75 on Axis) - X - L,O,P,Q,R,U,Y X X - X X E70-241575W-FN 3100 X - X 15(75 on Axis) - - X L,O,P,Q,R,U,Y X X - X X E70-R 7866 X X - - X - - Q,U XX X XX E70-W 7868 X X - - - X - Q,U XX X XX E70-N 3108 X X - - - - X Q,U XX X XX E70-24MCC-FW 0102 X X 115/177 - X - Q,U,V XX X XX E70-24MCWH-FR 3470 X - X 135/185 X - - L,O,P,Q,R,U,Y X X X X - E70-24MCWH-FW 3474 X - X 135/185 - X - L,O,P,Q,R,U,Y X X X X - E70-24MCWH-FN 0059 X - X 135/185 - - X Q,U X X X X - E90-24MCC-FW 3166 - X X 15/30/75/95 - X - Q,U,V X X X X - E90-24MCC-FR 3165 - X X 15/30/75/95 X - - Q,U,V X X X X - E90-24MCC-FN 3185 - X X 15/30/75/95 - - X Q,U,V X X X X - E90-W 7869 X X - - - X - Q,U,V XX X XX E90-R 7867 X X - - X - - Q,U,V XX X XX E90-N 3109 X X - - - - X Q,U,V X X X X X E90-24MCCH-FW 3471 - X X 115/177 - X - Q,U,V X X X X - E90-24MCCH-FR 3481 - X X 115/177 X - - Q,U,V X X X X - E90-24MCCH-FN 0062 - X X 115/177 - - X Q,U,V X X X X - Also comes in NW(no writting).Models available with no writting,may be subject to minimum quantity order. Architects and Engineers Specifications The speaker appliances shall be Wheelock Series E Speakers and the speaker strobe appliances shall be Wheelock Series E Speaker Strobes or approved equals.The speakers shall be UL Listed under Standard 1480 for Fire Protective Service and speakers equipped with strobes shall be listed under UL Standard 1971 for Emergency Devices for the Hearing-Impaired. In addition,the strobes shall be certified to meet the requirements of FCC Part 15,Class B. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS,with selectable power taps from 1/8 watt to 2 watts. - All models shall have listed sound output of up to 87 dB at 10 feet and a listed frequency response of 400 to 4000 Hz.The speaker shall also incorporate a sealed back construction.All inputs shall employ terminals that accept#12 to#18 AWG wire sizes. The strobe portion of the appliance shall produce a flash rate of one(1)flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens.The strobe shall be of low current design.Where Multi-Candela Speaker Strobes are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required(e.g.ADA compliance). When synchronization is required,the strobe portion of the appliance shall be compatible with Wheelock DSM sync modules,Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e.,contacts remain closed),the strobe shall revert to a non-synchronized flash rate. The speaker and speaker strobe appliances shall be designed for indoor surface or flush mounting.The speaker and speaker strobe shall incorporate a speaker mounting plate with a grille cover which is secured with two screws for a level, aesthetic finish and shall mount to standard electrical hardware requiring no additional trimplate or adapter. The finish of the Series E speakers and strobe speakers shall be white,red,or nickel plate. All speaker and speaker strobe appliances shall be backward compatible. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY S1610 E70/E90 06/11 NJ Location 273 Branchport Ave. Long Branch,NJ 07740 P:800-631-2148 F:732-222-8707 www.coopernotification.com OOP Cooper Notification is Wheelock®(MEDC) SAFEPATH' WAVES, COOPER Notification HN Series Effective November 2016 HS Series Technical Data TD450049EN Supersedes October 2014 ST Series Exceder Strobe, Horn Strobe, and Horn Notification Appliances .. - ,, Description The Wheelock Exceder Series of notification appliances feature a sleek modern design that will please building owners � with its reduced total costfeature of ownership including Installersthe will benefitdela from r; comprehensive listmost canoptions � f in one appliance,low current draw,no tools needed for setting a .,.. changes,voltage test points, 12/24 VDC operation,universal ii - mounting base and multiple mounting options for both new and i� - retrofit construction. . `° The Wheelock Exceder Series incorporates high reliability and high — FIRE efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit.All strobe . models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings(90,95, s,\ , )t..!.4 i,„ r 99 dB).All switches to change settings,can be set without the use �{ '< Y of a tool and are located behind the appliance to prevent tampering. V j - Wall models feature voltage test points to take readings with a f, voltage meter for troubleshooting and AHJ inspection. sThe Wheelock Exceder Series of wall and ceiling notification . j appliances feature a Universal Mounting Base(UMB)designed r to simplify the installation and testing of horns,strobes,and combination horn strobes.The separate universal mounting base ,, can be pre-wired to allow full testing of circuit wiring before the _ `i' appliance is installed and the surface is finished. It comes complete 4,' with a Contact Cover for protection against dirt,dust,paint and damage to the contacts.The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. t The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed.The UMB allows for consistent installation and easy replacement of appliances if required.Wall models provide an optional locking screw for extra secure installation,while the ceiling models provide a captivated screw to prevent the screw from falling during installation. EX•N Powering Business Worldwide Technical Data TD450049EN HN Series Effective November 2016 HS Series ST Series Features • Environmentally friendly • Sleek modern aesthetics Low current draw • Finger slide switches • Up to 9 models now in 1 appliance draw® • Voltage test points • 12/24VDC on a single appliance • Multiple voltages • Easy to remember model numbers ®Patented • 3 Audible settings • 90,95,99 dB Note:Please read these specifications and associated installation instruc- tions,before using,specifying,or installing this product.Visit Eaton.com/ • Industry leading-8 candela settings on 1 device massnotification for current installation instructions. • Wall: 15/1575/30/75/95/110/135/185 General Notes • Ceiling: 15/30/60/75/95/115/150/177 • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range" • All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. • Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F(0°C to 49°C)and maximum humidity of 93% (±2%) UL 464(85% UL 1971). • Series Exceder horns are under UL Standard 464 for audible signal appliances(Indoor use only). Compatibility and requirements • Synchronize using the Wheelock®Sync Modules or panels with built-in Wheelock®Patented Sync Protocol • Universal mouting base • Compatible with UL"Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage • Ceiling and wall • Strobes produce 1 flash per second over the"Regulated • Mounts to 5 backbox types: 1 gang,2 gang,4" square, Voltage" range 3.5"octal. &4"octal. (100mm for international customers) Universal mounting base Contact cover Compliance due; • UL 1971, UL 464, ULC,CSFM, FM • ADA/NFPA/ANSI/OSHA • RoHS Common base for wall and ceiling with 5 mounting options • Voltage test points for quick troubleshooting and easy spot checking(wall models only) o n X44: ,. e' Wu ,. . , ,. 2 EATON www.eaton.com HN Series Technical Data TD450049EN HS Series Effective November 2016 ST Series Table 1. Strobe Ratings per UL Standard 1971 UL Max Current® 24 VDC/24 FWR 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 ST 8.0-33.0 0.057 0.070 0.085 - 0.135 0.163 0.182 - 0.205 - - 0.253 0.110 0.140 STC 8.0-33.0 0.061 - 0.085 0.103 0.135 0.163 - 0.182 - 0.205 0.253 - 0.110 - Table 2. Horn Strobe Ratings per UL 1971 &Anechoic at 24VDC UL Max Current®at Anechoic 99 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.082 0.095 0.102 - 0.148 0.176 0.197 - 0.242 - - 0.282 0.125 0.159 HSC 8.0-33.0 0.082 - 0.102 0.141 0.148 0.176 - 0.197 - 0.242 0.282 - 0.125 - UL Max Current®at Anechoic 95 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 - 0.139 0.163 0.186 - 0.230 - - 0.282 0.122 0.153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163 - 0.186 - 0.230 0.272 - 0.122 - UL Max Current®at Anechoic 90 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 - 0.226 - - 0.267 0.120 0.148 HSC 8.0-33.0 0.065 - 0.084 0.120 0.136 0.157 - 0.184 - 0.226 0.267 - 0.120 - r®UL max current rating is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units).For strobes the UL max current is usually at the minimum listed voltage(16 VDC for 24 VDC units).For audibles the max current is usually at the maximum listed voltage(33 VDC for 24 VDC units).For unfiltered ratings,see installation instructions. Table 3. Horn Ratings per UL Anechoic Model Legend Regulated Voltage Model Range VDC 99 dB 95 dB 90 dB HN = Horn R = Red HN 16-33.0 0.064 0.044 0.022 ST = Strobe A = Agent Lettering(strobes only) HNC 16-33.0 0.084 0.044 0.022 HS = Horn Strobe AL = Alert Lettering(strobes only) HN 8.0-17.5 0.047 0.026 0.017 C = Ceiling Mount N = No Lettering(strobes only) HNC 8.0-17.5 0.047 0.026 0.017 W = White Example 1:STRC=Strobe,Red,Ceiling Mount Table 4. Specification&Ordering Information Example 2:HSR=Horn Strobe,Red,Wall Mount sync w/DSM or Example 3:HSW=Horn Strobe,White,Wall Mount Wheelock Power 12/24 Mounting Example 4:STW-AL=Strobe,White,Wall Mount,Alert Lettering Model Strobe Candela Supplies VDC® Options Horn Strobes HSR 15/1575/30/75/95/110/135/185 X X UMB® 7L F HSW 15/1575/30/75/95/110/135/185 X X UMB® .. ti HSRC 15/30/60/75/95/115/150/177 X X UMB® - HSWC 15/30/60/75/95/115/150/177 X X UMB® /4/"/Str obes �' STR 15/1575/30/75/95/110/135/185 X X UMB® A. ,4 x w✓� ,. STW 15/1575/30/75/95/110/135/185 X X UMB® STRC 15/30/60/75/95/115/150/177 X X UMBO "• SIWC 15/30/60/75/95/115/150/177 X X UMB® Horn HNR X X UMB® 'a HNW X X UMB® / r ■ HNRC X X UMB® Example:HSR Example:HSWC HNWC X X UMB® ,p 12 VDC models feature 15&15/75 settings ®UMB=Universal Mounting Base EATON www.eaton.com 3 Technical Data TD450049EN HN Series Effective November 2016 HS Series ST Series Architects and Engineers Specifications • The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection Service.The Series HS and HN Audibles shall be UL Listed under Standard 464(Fire Protective Signaling).All Series shall meet the requirements of FCC Part 15 Class B.All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel(FACP)with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one(1)flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens.The Series shall be of low current design.Where multi- candela appliances are specified,the strobe intensity shall have 8 field selectable settings at 15, 15/75,30, 75,95, 110, 135, 185 candela for wall mount and 15,30,60,75,95, 115, 150, 177 candela for ceiling mount.The selector switch for selecting the candela shall be tamper resistant.The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g.,ADA compliance).Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three(3)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3)audible outputs. The Series HS Audible Strobe,ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang,double-gang,4-inch square,3.5-inch octal,4-inch octal or 100mm European type back boxes.Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel(FACP).The mounting base shall be the same base among all horn, strobe,horn strobe,wall and ceiling models.All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58"W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58"W x 1.6"D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68"x 2.63" D.Series HNC ceiling shall have a diameter of 6.68"x 1.50" D. When synchronization is required,the appliance shall be compatible with Wheelock's DSM Sync Modules,Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate,the strobe shall revert to a non-synchronized flash-rate and still maintain (1)flash per second over its Regulated Voltage Range.The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wall Appliances:UL Standard 1971, UL Standard 464,California State Fire Marshal(CSFM), ULC, FM, RoHS Ceiling Appliances:UL Standard 1971, UL Standard 464,California State Fire Marshal(CSFM), ULC, FM, RoHS Note:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Eaton standard terms and conditions. Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland,OH 44122 United States Eaton.com Eaton Life safety&mass notification solutions 273 Branchport Ave. Long Branch,NJ 07740 Eaton.com/massnotification ®2016 Eaton E�� All Rights Reserved - Printed in USA Eaton is a registered trademark. Publication No.TD450049EN All other trademarks are property Powering Business Worldwide November 2016 of their respective owners. SIEMENS Sheet Fire Safety& Security Products Intelligent Detection Devices TRI Series — Intelligent Initiating Interface Modules [For use with FireFinder® XLS and MXL Panels] Models TRI-D, TRI-R and TRI-S ARCHITECT AND ENGINEER SPECIFICATIONS • Used as an intelligent initiating interface module for the FireFinder XLS and MXL fire-alarm control panels(FACPs) • Interfaces and supervises normally open (N.0)contacts • Integral single-pole,double-throw(SPDT)relay(up to 4 amps),Model TRI-R • Dual input for Model TRI-D • Multi-color light-emitting diode(LED) indicates detector status (green,arrebet,red) • Simple front-end access to programming port and wiring terminals & • Mounts in a 4"-square,2-1/8"-deep standard or double-gang box =e c a �Er, • Dynamic supervision ta • 5-x-5-inch faceplate included • Two-wire operation „ '• Compatible with Model DPU or FPI-32 field programmer/tester • Electronic-address programming is simple and dependable • ®UL Listed,IULC Listed; CSFM and NYC Fire Department Approved Product Overview The Model TRT-series of intelligent interface The sole purpose of Model TRI-S is to monitor and modules from Siemens—Fire Safety is designed to report the status of the contact,while Model TRI-R provide the means of interfacing direct shorting incorporates an addressable'Form C'relay. The devices to Model MLC for the FireFinder XLS FACP, relay and contact device input for Model TRI-R are or to Model ALD for the MXL system, respectively. controlled at the same address. The relay and input The Model TRI-series of intelligent interface contact can be controlled as a separate function. modules provides the most advanced method of The relay is typically used where control or shunting address programming and supervision—combined of external equipment is required. with sophisticated FACP communication. Each Model TRI-D is a dual-input module that is designed to Model TRI-series interface module incorporates a supervise and monitor two(2)sets of dry contacts. microcomputer chip. In turn,the microcomputer- Model TRI-D requires two(2)address settings. Model chip technology and its sophisticated bi-directional TRI-D is ideal for monitoring a waterflow switch and its communication capabilities with the FACP, achieve respective valve tamper switch. the state of an'Intelligent Device.' Model TRI-series has a multi-color LED that flashes Specifications green when operating normally;an;bcr,if unit is in trouble condition, and red to indicate a change of The Model TRI-series of intelligent interface status command. Model TRI-D flashes two(2)times— modules is available in three (3) models. Models once for each address,and the red LED of Model TRI-R TRI-S and TRI-R are designed to monitor a normally indicates a change of state in the relay. open (N.O.) dry contact. The interface module reports the contact's status to the FACP. w TRI Series —Intelligent Initiating Interface Modules (9 SIEMENS Industry, Inc. Building Technologies Division Specifications — (continued) Electrical Ratings . The microcomputer chip for the Model TRI-series of Current Draw: devices has the capacity of storing—in memory— [Active or Standby] 1.5mA identification information as well as important Model TRI-R Relay Ratings: operating status information. Resistive: 4A, 125VAC Siemens—Fire Safety innovative technology allows 4A,30VDC all Model TRI-series intelligent interface modules to 3.5A,120VAC[0.6 P.F] be programmed and tested,via Model DPU or the 3.0A,30VDC[0.6 P.F] FPI-32 Programmer/Tester. Each of these Inductive: z.OA, 120VAC[0.4 P.F] programmer/testers is a compact, portable and z.oA, 12OVAC[0.35 P.Fj menu-driven accessory that makes programming z.OA, 120VAC[0.35 P.F] and testing an interface device faster,easier and more dependable than previous methods. Model DPU or the FPI-32 eliminates the need for Mounting Diagram mechanical addressing mechanisms(such as: MOUNTING SLOTS CH program jumpers, DIP switches,or rotarydials), WI ctii o ) srvtrCrdaox since either programmer/tester device electronically sets the address of the Model TRI- series into the interface's microcomputer-chip, non- 0 o 4 y` volatile memory. Vibration,corrosion and other rR€-s/t�rR CI conditions that deteriorate mechanical addressing 2 � � MLL�ULE mechanisms are no longer a cause for concern. I 3 14 4 The Model TRI series of intelligent interface S �' MOUNTING HOLES FOR modules is fitted with screw terminals for ° I HMOLES PL&TE connection to an addressable circuit,and is fully g compatible on the same circuit with all intelligent Model FP; Model IL and Model ID-60-series 'Q o 0 detectors; Model MSI Series addressable manual stations,or any other addressable intelligent modules,such as Model CZM or Model ICP. OR DOUe E-GANG All Model TRI-series intelligent interface modules S4VtTCHBOX are®UL and "ULC Listed. Details for Ordering Model Part Shipping Weight Nurnbe Number Description Oz t K g TRI-D 500 896226 Dual-Input Intelligent Interface Module 7 0.2 Single-Input lwl relay] TRI-R 500-896224 Intelligent Interface 7 0.2 Module Single-Input i TRI-S 500-896225 Intelligent Interface 7 I 0.2 Module Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information,refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park,NJ 07932 Brampton,Ontario Building Technologies Division Tel:(973)593-2600 (SII-FS) L6T5E4/Canada July 2012 FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 Supersedes sheet dated 5/06 URL:www.usa.Siemens.com/Fire FAX:(905)799-9858 (Rev.1) SIEMENSData Fire Safety Products Intelligent Detection Devices Intelligent FirePrintTM Detector [For use with Firerinder® XLS and MXL® Panels] Model FP-11 ARCHITECT AND ENGINEER SPECIFICATIONS • Multi-criteria fire detection • Sophisticated'detector intelligence' • Remote-sensitivity-measurement capability • Easily programmed to match specific hazard profiles from the fire-alarm control panel (FACP) • FIrePrrntTM technology to distinguish between deceptive phenomena and an actual fire • • Pre-Alarm reporting based upon fire profile selected • Field-cleanable chamber with replaceable chamber parts • System-logic activation based upon any of three (3) inputs from the detector(smoke,heat or neural network) • Supports software-based,automatic environmental compensation • EnviroLINK • Compatible with field programmer/tester Multi color,detector status • Model DPU I FPI-32 Upgrade Kit • Backward compatible with older MXL systems light emitting diode (LED) • Two wire operation • Rev.2 and above • Optional fully programmable relay base,audible base and duct housing • ®UL and®ULC Listed; FM,CSFM &NYCFD Approved Product Overview The Intelligent Fire Detector(Model FP-11) is a The upgrade kit (Models DPU or FPI 32) eliminates highly evolved detection system that provides a the need for cumbersome, unreliable mechanical very sophisticated level of fire protection,along with superior immunity to nuisance-alarms. Model FP-11 utilizes highly developed detection programming methods, as well as reduces installation and service costs by electronically programming and testing the detector prior to installation. technology that allows the detector to distinguish Specifications non-threatening deceptive phenomena (i.e. — Model FP 11 is a plug-in, two wire and multi sensor cigarette smoke)from actual fire hazards,while detector with photoelectric and thermal inputs that is optimizing detection for the area of its intended zone. Model FP-11 uses state-of-the-art compatible with the FireFinder XLS and MXL family of FACPs. Each detector consists of a dust resistant, microprocessor circuitry with error check; detector self-diagnostics,and supervision programs. Model FP-11 is compatible with the Siemens — Fire Safety Model FPI-32 upgrade kit or Siemens' field cleanable photo chamber; a solid-state, non- mechanical thermal sensor, and microprocessor based electronics with a low profile plastic cover and base. • Model FP 11 utilizes state-of-the-art ASIC and surface- mount I tester, Model DPU I FPI-32, mount technology for maximum reliability. which is a compact, portable and menu-driven Every Model FP 11 fire detector is shipped with a accessory for efficiently programming and testing protective dust cover. Model FP 11 fire detector detectors electronically. utilizes an infrared light emitting diode (IRLED), and light-sensing photodiode. Intelligent FirePrintTM Detector 6175 SIEMENSIndustry, Inc. Building Technologies Division Specifications — (continued) Under normal conditions, light transmitted by the LED The FirePrint technology for Model FP-11 monitors is directed away from the photodiode and scattered input from the photo chamber and the thermal through the smoke chamber in a controlled pattern. sensor,evaluating this information with sophisticated The smoke chamber is designed to manage light mathematical formulas or algorithms,and compares dissipation and extraneous reflections from dust data transfer to this input to the characteristics of particles or other non-smoke airborne contaminants in both threatening fires and deceptive phenomena that such a way as to maintain stable, consistent detector would deceive any ordinary detector. operation. When smoke enters the detector chamber, This technology was developed over years of research light emitted from the IRLED is scattered by the smoke and reviewing the results of over 20 years of fire-test particles,and is received by the photodiode. data in one of the world's most advanced fire research Model FP 11 also utilizes a modern,accurate and centers. The results of this research are the mathematical models that form the algorithms used shock-resistant thermistor to sense temperature in FirePrint. No other fire detector has this level of changes. The'on-board'FirePrint technology allows the detector to gather smoke and thermal intelligence or this amount of research and data,analyzing this data in the detector's'neural development supporting its design. network.' By comparing data received with the The software of the microprocessor can identify and common characteristics of fires,or fire fingerprints, disregard false input caused by radio frequency(RFI) Model FP-11 can compare these'fire prints'to those and electromagnetic(EMI) interference,and validates of deceptive phenomena that cause other detectors all Trouble conditions before annunciating or to go into Alarm mode. reporting to the control panel. The microprocessor This advanced FirePrint technology allows Model for Model FP 11 uses an integral electronically FP 11 to accurately determine a true fire hazard from erasable programmable read-only memory(EEPROM) to store the detector's address and other critical non-threatening,deceptive phenomena—without the operating parameters,which include the assigned need to use alarm-delaying verification and program values for Alarm and Trouble—command confirmation techniques;thus decreasing the thresholds. probability of losses in infrastructure from an actual fire. Communications within the detector; between Model Model FP-11 provides the highest level of detector FP-11 and the FACP,or with the field programmer/ intelligence available today with a detector/control- tester(Model DPU/FPI-32),are supervised and panel link that allows the user to program the safeguarded against disruption by reliable, detector for the specific hazard profile. microprocessor-based error checking routines. Detectors are optimized by selecting one (1)of Additionally,the microprocessor supervises all the following applications: EEPROM memory locations and provides a high • Office 1 Retail degree of EEPROM failure fault tolerance. • Lobby Model FP-11 determines its operating status(Normal, • Computer room Alarm, or Trouble modes) based upon the difference • Dormitory between the alarm-threshold values stored in the • Healthcare facility detector's memory and the detector's latest analog • Parking garage measurement. The detector then communicates • Utility 1 transformer room changes in its status to the FACP. • Hostile environment • Precious storage In addition,the FACP will sample the value of the • Air duct analog signal for Model FP-11 over a period of time, in • Warehouse Night manufacturing order to determine if those values indicate excessive buildup in the photo chamber. In the event of Once programmed,the software does the rest— excessive buildup,the FACP will accurately indicate no guessing on detector sensitivities or alarm which detector shall require maintenance. verification —the FACP programs Model FP-11 for the Model FP 11 is listed as a self testing device. The LED protected area without any confirmation delays. for Model FP-11 flashes green every four(4)seconds, Once optimized for the hazards in the protected area, indicating communication with the FACP,and that it Model FP-11 provides the utmost means in detection. has passed its self-test. Should the detector sense a Should the operator or installer forget fault or failure within its systems,the LED will flash to program the detector, Model FP-11 will revert amber,and the detector will transmit that data to the to a default setting that, in turn,allows operation FACP. A quick visual inspection is sufficient to as a standard photoelectric or photothermal detector. indicate the condition of the detector at any time. SIEMENS Industry,Inc. Building Technologies Division Specifications — (continued) If more detailed information is required,a printed All Model FP-11 detectors can be cleaned in the field— report can be provided from the FACP, indicating the when required — by simply removing the detector status and settings assigned to each detector. cover and unsnapping the photo chamber. There is When Model FP 11 activates into Alarm mode,the also the option of cleaning the interior of the detector detector will flash amber,and will transmit that data with a clean,soft cloth or brush,or replacing the to the FACP. When the FACP confirms the condition labyrinth and bug screen included in the detector of the detector,the FACP will instruct Model FP-11 to maintenance kit, Model DMK 11. flash red—and continue to flash red— until the Model FP-11 uses the low-profile,surface-mounting system is reset manually at the FACP. At that same base, Model DB-11. This base mounts on a 4-inch time,any user-defined system alarm functions (10.2 cm.)octagon,square,or a single-gang electrical programmed into the system are activated. Each box. The base utilizes screw-clamp contacts for Model FP-11 detector can operate one (1) remote electrical connections and self-wiping contacts for alarm indicator;one(1)auxiliary relay,or one (1) increased reliability. audible base. The base can be used with the optional Model LK-11 Detector sensitivity,calibration and identification detector locking kit,which contains 50 detector locks, are dynamically supervised by the FACP. Detector as well as an installation tool,thus preventing sensitivity and pre-Alarm levels are a function of the unauthorized removal of the detector head. Model application chosen at the FACP,and are controlled DB 11 has integral,decorative plugs to cover the by the panel. If an alternate, non-FirePrint mode is outer mounting screw holes. selected,then the sensitivity can be changed from Model FP-11 is electrically compatible with existing the FACP. MXL-detector accessories, including relays, remote The Program 1 Test unit(Model DPU or FPI-32) lamps,duct housings and audible bases. To use existing Model DB-3S base or audible base, Model upgrade kit is used to program and verify the detector's address.The technician selects the FP 11 requires a base adapter(Model DB-ADPT). accessory's program mode to enter the desired Application Data address. Consequently,the programmer unit(Model Installation of the Model FP 11 series of fire detectors DPU or FPI-32)will automatically set and verify the address, and tests the detector. Model DPU I FPI 32 requires a (2)two-wire circuit of 18 American Wire also allows the user to change the device ID from that Gauge(AWG), minimum,thermoplastic fixture wire enclosed in conduit,or 18 AWG (American Wire of a Model FP-11 detector to an older detector ID Gauge) limited-energy,shielded-cable without (such as: ILP-1,ILPT-1,ILP-2,ID-60P or ID-60PT)to conduit,if permitted by local codes. Field wiring allow for easy replacement of older detectors without should conform to local and national electric codes the need of reprogramming the FACP. and the control panel wiring specifications. The FPI-32 upgrade kit operates on AC power or 'T-tapping'is permitted only for Style 4 (Class B) rechargeable batteries, providing flexibility and wiring. convenience in programming and testing equipment Model FP-11 fire detectors can be applied within the from almost any location. When in'test'mode, Model maximum 30-foot center spacing (900 sq.ft.areas), DPU or FPI-32 upgrade kit will perform a series of as referenced in NFPA 72. This applications guideline diagnostic tests without altering the address or other is based upon ideal conditions—specifically—smooth stored data,allowing technicians to determine if the ceiling surfaces, minimal air movement,and no detector is operating properly. physical obstructions between potential fire sources Model FP-11 may be installed on the same initiating and the detector. Do not mount detectors in close circuit with Models IL or ID series detectors proximity to ventilation or heating and air- (Photoelectric,thermal,or ionization); Model MSI- conditioning outlets. series manual stations; Model TRI-series interfaces; Exposed joints or beamed ceilings may also affect safe Model ICP output-control devices,or Model CZM spacing limitations for detectors.Should questions series of addressable,conventional-zone modules. arise regarding detector placement,observe National Fire Protection Association (NFPA) 72 guidelines. SIEMENS Industry, Inc. Building Technologies Division Technical Data Details for Ordering Environment Part Temperature:al• 32°F(0°C)to 100°F(38°C) Model Number Description Humidity: Up to 93%RH, non-condensing FP-11 500-095112 Addressable FirePrintTM Detector Air Pressure: No effect Detector Mounting Base Alarm Temperature: 135°F(57°C) DB 11 500-094151 For Series 11 Intelligent Detectors ADBX-11 500-096181 Audible Base Electrical Voltage: 16—27 VDC DB-11E 500-094151E Detector Base(Small) Ripple: 3V, peak-to-peak DB-ADPT 500-094187 Base Adapter to Model DB-35 Base Supervisory Current: 110NA max DB-X11 RS 500-096125 Relay Base for Model 11-series Alarm Current: 33—50mA Intelligent Detectors DMK 11 500-695338 Model 11-series Maintenance Kit (replacement labyrinth and bug screen) Air-Duct Housing_ Dimensions A two-wire addressable or conventiona duct detector(without relays)designed for -- ---Diameter Base direct use on heating, ventilating and air- [t SBs cm] FDBZ492 854319-B22-A1 conditioning(HVAC)air-duct systems. lr When equipped, the air-duct detector housing will signal the presenceof smoke being carried through the duct system. __Air-Duct Housing A two-wire addressable duct detector Height (with relays)designed for direct use to 3* �-"1 HVAC air-duct systems. [S.E cm] FDBZ492-554319-B23-A1 This part has aro rammable relaybase, C16 ��'� HR and when equipped,p the addressable air- ' UNvAi duct detector housing will signal the -- ------- presence of smoke being carried through the duct system. LK-11 500-695350 Base Locking Kit for Series 11 Detectors RLI-1 500-390673 Remote Alarm Indicator 4"Octagon Box Mount,Red RLI-2 500-390674 Remote Alarm Indicator Single-Gang Mount,Red In Canada, please order: Thi Part 13'-I Description Number MAW "° 135°F Fixed Temperature,Plug-In FP-11C 500-095112C Detector Addressable FirePrintTM Detector[@ULC Listed] Detector Mounting Base DB-11C 500-095687 (for Model 11-series Intelligent Detectors) [ ULC Listed] Relay Base for Model 11-series DB-X11 RSC 500-093125C Intelligent Detectors[QULC Listed] ADBX 11 C 500-096181C Audible Base for Model 11-series Intelligent Detectors[(ULC Listed] Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information,refer to each product's installation instructions. 8 Fernwood Road 1577 North Service Road SIEMENS Industry,Inc. Florham Park,NJ 07932 East Oakville,Ontario May 2016 Building Technologies Division Tel:(973)593-2600 (sis-Fs) L6H OH6 I Canada Supersedes sheet dated 6/2012 FAX:(908)547-6877 Printed in U.S.A. Tel:[905]465-8000 (Rev.3) URL:www.usa.siemens.com/FIRE URL:www.Siemens.CA SIEMENS Data Sheet Fire Safety& Security Products Specialized Devices Air-Duct Housings —> FDBZ Series Models FDBZ492, FDBZ492-HR, FDBZ492-R and FDBZ492-RP (with FDBZ-WT and FDBZ492-RTL) ARCHITECT AND ENGINEER SPECIFICATIONS • Four(4)models available • Addressable and conventional(with and without relays) at • Compatible with Siemens—Fire Safety conventional •°&. and addressable fire-alarm control panels(FACPs) "` " ° ~~� FDBZ series of air-duct housings • Magnet test feature with the Model OP1 21 (FDBZ492,FDBZ492-HR,air-duct and FDBZ492-RP) s« conventional detector Remote alarm • Design for air-velocity range of 100 to 4,000 indicator (Model FDBZ492-RTL) .:<• feet-per-minute(fpm) • Robust,compatible conventional remote indicator test switch that incorporates tri-color light-emitting diode(LED) • Clear housing cover with smoke test port on cover for quick identification of detector type »i - �� • Removable with four(4)captive-thumb screws(no tools required) �t�i1 ;• „�. ���L ��'$ r • Includes a smoke 1 aerosol detector test port l�.t,="` Watertighthousing • Optional NEMA 4X-reinforced,stainless-steel and (Modl FDBZ-WT watertight enclosure available,Model FDBZ WT • Self-contained model available with'on-board' • No tools required for cover removal,sampling and power supply for conventional detectors exhaust-tube installations • Expanded temperature range • Trouble-event activation upon front-cover removal • Relay models available • Alarm LED visible from front • 4UL268A Listed,fULC-S529 Listed Product Overview The Siemens—Fire Safety Model'FDBZ'-series of air- Notes-(cont.'d): With either the DesigoT'series or FireFinder® duct-detector housings are designed to be used with XLS series of FACPs,up to 252-addressable detectors with the Siemens Model'H'-series,'FD'-series and the Model relays per circuit may be used.The connection of an intelligent remote lamp(ILED)and a remote relay is allowed for each OP121 detectors. Designed for installation directly to detector simultaneously. heating,ventilating and air-conditioning(HVAC)duct systems,the Model'FDBZ'-series complies with National Specifications Fire Protection Association Standard(NFPA)No.'s 72 The Model'FDBZ'-series of air-duct housings are uniquely and 90A,and is Underwriters'Laboratories Listed. designed to use with the photoelectric detector. Sensitivity When equipped,the air-duct detector housing will of Models PE 11,PE-11C and OP121 detectors can be signal the presence of smoke being carried through the verified for calibration via LED visual status or a Model duct system. Air-duct detectors are not intended to be RSAW 11,Model RSAC 11 or Model FDBZ492-RTL multi substituted for open area detection. color remote lamp. A green flash indicates the detector has passed its self test. Amber indicates a Trouble Notes: Most conventional time-control equipment condition,and red indicates an Alarm event. guarantee only one(1)detector per zone when the detector's operated relay function is critical. Sensitivity for Models HFP-11,FP-11,SFP-11,HFPO-11, The connection of a remote lamp and a remote relay SFPO-11,FD0421,FDOOT441 and FDOOTC441 is verified -per detector- is allowed. from the multi-color LED of the respective detector,or its Refer to the installation manual for the respective sensitivity reading may be printed by command from the conventional fire system. corresponding FACP to an optional printer. Model `FDBZ'—Series of Air-Duct Housings and Detectors 6156 SIEMENS Industry, Inc. Building Technologies Division Specifications — (continued) Sampling Tube Selection Table The remote alarm indicator(Model FDBZ492-RTL)allows Duct Width I Sampling Tube for manual testing via a key-switch for conventional and (Model No.) addressable detectors,as well as the conventional and For duct widths 6"to 1' ST-10 addressable air-duct housing with relay. Model For duct widths 1'to 3' ST-25 FDBZ492-RTL,which mounts remotely from the For duct widths 3'to 5' conventional and addressable air duct housing,allows (requires support) ST-50 for manual relay output control. The duct detector For duct widths 5'to 10' (requires support) ST-100 remote indicator key-switch also indicates the current state of the detector. Maintenance of the detector is easily accomplished The watertight housing (Model FDBZ-WT),which allows via the removal of the duct-housing sampling the air-duct detector housing to be installed inside the chamber cover.The detector, which plugs into the separate NEMA 4X enclosure, is for installations for housing, is easily removed for cleaning or replacing by either an outdoor area or in environments where a trained technician. excessive moisture is prevalent. All that is necessary for installation of the air-duct Each detector unit employs a cross-sectional sampling detector is the cutting of three(3) small holes for the principle of operation. Inlet sampling tubes are Sampling Tube installation (template included), and available in four(4)lengths(see: Sampling Tube the drilling of two(2) holes for mounting the air-duct Selection Table). Outlet sampling tubes are one(1) housing. The unit is then easily mounted in place, common length and draw. A continuous,cross- and connection made to the existing wires or sectional sample of air moves through the duct. terminals—if optional accessories are utilized. No Stratification or skin affect phenomenon that occurs in mechanical tools are required for removing the cover or the duct can prevent smoke(especially in large ducts) connecting the sampling and exhaust tubes to an air- from reaching a spot-type detector. duct housing. In addition,the unique design of the sampling chamber Models ST-50 and ST-100 require support. However, insures uniform sensitivity in air velocities,ranging Model ST-100 is shipped in two(2) 5-ft. (152 cm.) from a low of 100 fpm to as high as 4,000 fpm. Each pieces with a coupling for field assembly. housing comes with three(3)wiring entry ports: • Two(2)3/4"conduit knockouts Technical Data • One(1)1/2"conduit opening Operating The inlet sampling tube length is determined by the Temperature +32°F(0°C)to 120°F(49°C) width of the air duct being protected. The inlet tube— Ranges: greater than and nearest to the duct width—should be used (see: Sampling Tube Selection Table).The inlet Sampling Tube Pressure >0.01 inches; tube can then be trimmed at the job site to the exact Range of Differences: <1.2 inches of water width of the duct.The outlet sampling tube for all ducts column —irrespective of width—has a fixed length of Relative Humidity: o—95%;non-condensing approximately 5.5 inches(14cm.),and is supplied with the air-duct housing. Air Pressure/ No effect 1 Note: When the use of a remote relay is required,order Altitude Range: No limitations Model FDBZ492-R for conventional systems;Model Air-Duct Velocity: 100—4,000 ft./min FDBZ492-HR for addressable systems.When required,a (0.51—20m I sec) separate watertight enclosure(Model FDBZ-WT),which is designed to contain the air-duct housings is Dimensions: {H-x-W-x-D} available. •Rectangular: 14.38"-x-5"-x-2.5" (For full details,refer to installation instructions for the (37 cm. x-12.7 cm.-x 6.36 cm.) respective air-duct housing.) •Square: 7.75"-x-9"-x-2.5" (19.7 cm.-x-22.9 cm.-x-6.36 cm.) Note: When a self-contained duct detector with power supply is required,order Model FDBZ492-RP. Detector Weight: 1.8 Lbs.(0.82 Kg.) (For full details,refer to installation instructions part number A6V10330327.) Notes to Architect: When building codes regulate the location of detectors within ventilating systems,make sure the number and locations of detectors are in accordance with the code regulations. For additional electrical specifications, please see the installation instructions of the corresponding air-duct housing. SIEMENS Industry, Inc. Building Technologies Division Operation Details for Ordering Based on the monitoring results,the LED indicator Model Part flashes the following colors based on the followingNumber Number Description _ h conditions: A two-wire addressable or conventional duct detector(without relays)designed for Flash direct use on heating,ventilating and air- Flash conditioning(HVAC)air-duct systems. Condition Interval When equipped,the air-duct detector (in seconds) Color housing will signal the presence of smoke FDBZ492 S54319-B22-A1 being carried through the duct system. Normal supervisory operation. For use with the following Models: Green*: Smoke sensitivity is within 10 - HFP-11 - FD0421 rated limits. - SFP-11 - FDOOT441 OP121 PE 11 Detector is in Trouble - HFPO-11 - FDOOTC441 _ PFE-11C Yellow: condition,and needs either 4 - SFPO-11 - FP-11 repair or replacement. A two-wire addressable duct detector(with relays)designed for direct use to HVAC air- Red: Alarm condition. 1 duct systems and works with the Remote Test Switch(FDBZ492-RTL).This part has a No Flash: Detector is not powered. -- programmable relay base,and when equipped,the addressable air-duct detector *LED can be turned OFF. FDBZ492-HR 554319-B23-A1 housing will signal the presence of smoke Please follow the corresponding description of the panel used. being carried through the duct system. For use with the following Models: - FD0421 - FP-11 - SFP-11 - FDOOT441 - HFP-11 - sFPO-11 - FDOOTC441 - HFPO-11 Products includedwiththe air-duct housing: Atwo-wire conventional duct detector with - (1)short-return(outlet)tube relays designed for direct use on HVAC air- - (1)stopper duct systems.This detector has a relay (1)stopper base,and when equipped with conventional - (2)#12+314"sheet-metal screws air-duct housing,will signal the presence of - (1)mounting template FDBZ492-R 554319-B24-A1 smoke being carried through the duct system. Note: Detector and sampling tube to be purchased separately. For use with the following Models: Minimum hardware required is: one(1)air-duct housing - PE-11 -PE-11C assembly;one(1)sampling tube and one(1)detector. - OP121 A four-wire conventional duct detector with relays and a built-in power supply. Housing is designed for direct use to HVAC air-duct systems. It has a relay base with a built-in power source.When equipped with FDBZ492-RP 554319-B25-A1 conventional air-duct housing,this duct detector will signal the presence of smoke being carried through the duct system. For use with the following Models: - PE-11 -PE-11C - OP121 Device is used for manual testing via a key- switch for duct-housing Models FDBZ492-R, FDBZ492-RP and FDBZ492-HR. Device mounts remotely from the conventional and addressable air-duct housing,allowing for FDBZ492-RTL 554319-S27-A1 manual relay-output control.The duct- detector remote key-switch also indicates the current state of the detector. -- -- For use with the following Models: - FDBZ492-R - FDBZ492-RP -FDBZ492-HR An optional,separate watertight NEMA 4X enclosure(Model FDBZ-WT)that provides added watertight protection for any of the Model FDBZ492-series duct housings.The duct housing fits into the separate 4X enclosure.This part allows the air-duct FDBZ-WT 554319-B26-A1 detector housing to be installed in the separate enclosure,and can be used in either an outdoor area or in environments where excessive moisture is prevalent. For use with the following Models: - FDBZ492 - FDBZ492-R - FDBZ492-HR - FDBZ492-RP ST-10 500-649710 Sampling tube for Ducts 6"to 1' ST-25 500-649711 Sampling tube for Ducts over 1'to 3' ST-50 500-649712 Sampling tube for Ducts 3"to 5' ST-100 500-649713 Sampling tube for Ducts 5'to 10' SIEMENS Industry, Inc. Building Technologies Division • Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information,refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park,NJ 07932 Brampton,Ontario BuildingTechnologies Division Tel:(973)593-2600 August 2013 9 (SII-FS) L6T 5E4/Canada Supersedes sheet dated 6/13 FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 URL:www.usa.Siemens.com/Fire FAX:(905)799-9858 1111111111111111111111111111.1"...1 ., COOPER Notification POWERPATHTM NAC POWER SUPPLIES $Ys�iiit; �owecaM PS-EXP PS-6 PS-8 Description The Wheelock Series PS-6 and PS-8 are 24VDC, filtered and The PS-6 and PS-8 Power Supplies are UL Listed under UL regulated, supervised remote power supply/battery chargers are Standard 864, 9th Edition to be used with any 24 volt Listed used for supervision and expanded power driving capability of Fire Regulated notification appliances.They include the capability Alarm Notification Appliance Circuits. The PS-6 provides 6 amps of to synchronize Wheelock strobes and horns and to silence the power distributed across 4 outputs,while the PS-8 provides 8 Amps horn signal when horn/strobes are operating on two wires. across 4 output. In addition the P5-8 provides additional room in the chassis for accessories like an Addressable Control Module,with Approvals mounting studs. •Approvals Include:UL Standard 864,1481,California State The Power Supplies may be connected to any 12V or 24V (FWR or Fire Marshal(CSFM), Factory Mutual(FM) DC) Fire Alarm Control Panel (FACP) by using a Notification Appliance .Compliant with NFPA 72 Circuit (NAC) or a"Dry Contact". Primary applications include NAC expansion (supports ADA requirements) and auxiliary power to support system accessories.This unit provides filtered and regulated Inputs 24VDC, up to four (4) Class"B", two (2) Class"A", or two (2) Class •120VAC,50/60Hz,4.25 Amps(PS-6/8)and 5.32 Amps "B"and one (1) Class"A"Notification Appliance Circuits.With the (PS-8)Operating Power in Alarm optional plug-in PS-EXP module the unit supports (8) Class"B"or •240VAC,60Hz,2.42 Amps(PS-6E and 3.22 Amps(PS-8E)' (4) Class"A"Notification Appliance Circuits.Additionally,an auxiliary Operating Power in Alarm power output of 2.5 Amps (disconnected upon AC power loss or an .24VDC Battery Backup Connection alarm condition)or up to 0.240 A of constant power on the PS-8 and .Two(2),12V or 24V NAC Initiating Circuits(8-33V at 5mA) 0.075 A of constant power on the P5-6. FWR or DC The Wheelock Power Supplies can accommodate 7 or 12 AH batteries •Two(2)"Dry"Contact initiating Circuits inside its lockable chassis. Using an external battery cabinet it can .Accepts two(2)Class"A"or two(2)Class"B"circuit inputs charge up to 33 AH batteries (pending UL testing). Two FACP NAC .Built in battery charger for sealed lead acid or gel type circuits or two"Dry"contact initiating circuits can be connected to the batteries inputs.These inputs can then be directed to control supervision and power delivery to any combination of the four(4)outputs.Each output is rated at 3.0 Amps(Class"B")or(Class"A")and can be programmed to generate a steady or Code 3 Temporal Horn sound and a strobe Outputs output under alarm condition.Total load for the PS-6 and P5-8 NAC •NAC outputs are 24VDC,3.0 Amps each,power limited circuits must not exceed the power supplies rated output. •8 Amps on PS-8 and 6 Amps on the PS-6 total alarm current The Power Suppliesunder non-alarm condition provides independent supervision for Class"A"and Class"B" FACP NAC circuits. In the event of circuit trouble,the FACP will be notified via the POWERPATH steered input (IN1 or IN2). In addition there are two sets of trouble reporting terminals, one used for AC power loss reporting and the other for all troubles.The AC power loss reporting, on the common trouble terminals and on IN1 or IN2, can be delayed for either 30 seconds or 170 minutes.The AC power loss terminals will always report the trouble within 1 second after loss of AC power. 1' "1 APPROVED ...Features continued on next page •Capable of four(4),Class"B"circuits •Capable of two(2)Class"A"circuits •Capable of one(1)Class"A"circuit and two(2)Class"B"circuits •Capable of(8)Class"B"or four(4)Class"A"circuits with optional PS-EXP module •Temporal(Code 3),constant voltage output,Wheelock Sync output or True input to output follower mode •Built-in Wheelock synchronization mode that can be fed to any or all of the output circuits •Input and output can be synchronized with"IN>OUT SYNC"mode(DSM,2nd POWERPATH'"or FACP with synchronization protocol is required) •Audible silence capability •Filtered and electronically regulated output •2.5 Amp auxiliary power limited output with reset capability.(Removed upon AC loss or alarm.Automatic reset 30 seconds after AC power returns or the alarm condition is over)or 0.075 Amps(PS-6)or 0.240 Amps(PS-8)of auxiliary power limited output which remains on during AC loss or an alarm condition when configured for 24 hour battery backup Supervision •Compatible with 12V or 24V(FWR or DC)FACP •Signaling appliance circuits are supervised and steered to either IN1 or IN2 •10K Ohm,1 Watt(Wheelock Model#MPEOL)End of Line Resistor(EOLR)for supervision of all outputs •37 distinguishable trouble diagnostics •AC loss trouble reported over a separate set of contacts(delay of 1 second) •All troubles are reported over the common trouble contacts(AC loss can have a delay of 30 seconds or 170 minutes) •Automatic switchover to standby battery when AC fails •Thermal and short circuit protection with auto reset •Input and output status LED indicators •AC fail supervision •Battery presence and low battery supervision •Ground Fault Detection,with diagnostics to indicate which circuit fault is on •Latching LED's for NAC trouble annunciation and Diagnostic trouble LED's(latching can be disabled) Power •Not Battery Dependent •Automatic switch over to standby batteries when AC fails •Supports sealed lead acid or gel type batteries •Fused battery protection •Thermal and short circuit protection with auto reset •Supports both 7AH or 12AH batteries in the same cabinet POWERPATH'Operating Modes(refer to Installation Manual): Normal Mode: Provides constant 24 VDC output upon initiation by a voltage to input IN1 or 1N2 or by a contact opening on DRY1 or DRY2.The unit returns to standby mode when the input is deactivated. Wheelock Sync Mode: Provides signals for synchronization of patented Wheelock audible and strobe notification appliances.Audibles can also be silenced in this mode while the strobes continue to flash. In>Out Sync Mode:Accepts a synchronization signal on the input to provide a coded output or synchronized output.This signal may come from a FACE,another POWERPATH or a Wheelock DSM synchronization module.Caution:Do not use strobes on coded output circuits. True Input Follower Mode: Accepts a coded signal on the input to provide a coded output with the same timing as the input. The signal may come from a FACE another POWERPATH or other coded source. Caution: Do not use strobes on coded output circuits. Temporal Mode: Codes the output voltage in a code-3 temporal pattern to drive audible appliances such as horns, bells or chimes.Caution:Do not use strobes on coded output circuits. Specifications and Ordering Information OrderApprovals Input Voltage/Current Model Number Code UL CSFM FM PS-6 105530 6 amp,red enclosure X X X PS-6B 100257 6 amp,black enclosure X X X PS-8 105531 8 amp,red enclosure X X X PS-8B 105830 8 amp,black enclosure X X X PS-6EXP 105083 6 amp power supply with preinstalled expansion module X X X PS-8EXP 105084 8 amp power supply with preinstalled expansion module X X X PS-EXP 105534 4 class B or 2 class A expansion module X X X PS-EXP-RETRO 105527 Field upgrade kit for models prior to January 2010" X X X Input Circuit Input Voltage and Current X=Approved Input voltage Range 8 to 33 VDC *=Pending Input Current @ 12 VDC 0.005 amps #=Contact Technical Support for additional Input Current @ 24 VDC 0.005 amps inforamation on upgrade Output Circuit Output Voltage and Current options Four(4)Class B or Two(2)Class A or One(1)Class A and Two(2)Class"B"or 24 VDC @ up to 3 amps per curcuit 8 Class B or 4 Class A (optional PS-EXP module necessary) Continuous duty up to 3 Amps per circuit,up to 4 Amps maximum per panel Standby Current 0.129 Amps Alarm Current 0.129 Amps Primary PS-6(120 VAC models) 105 to 130 VAC,50/60 Hz @ 4.25 Amps Primary P5-8(120VAC models) 105 to 130 VAC 50/60 Hz @ 5.32 Amps Primary PS-6E(240 VAC models) 210 to 260 VAC,50/60 Hz @ 2.42 Amps Primary PS-8E(240 VAC models) 210 to 260 VAC 50/60 Hz @ 3.22 Amps Secondary Power Charging Capacity 32 Amp hours @ 0.750 Amps per hour Enclosure can house up to two 12 AH batteries Aux Output CP Mode PS-6 up to 75 mA PS-8 up to 250 mA MP Mode 2.5A during non alarm Model Dimensions Weight Comments PS-6/PS-6B 17"H x 13"W x 3.5"D 11.5lbs.(Ship)9.4lbs(Unit) Small profile PS-8/PS-8B 17"H x 15"W x 5.5"D 17.71bs(Ship)15.6lbs(Unit) Additional room for modules Plugs into main pcb on all PS-EXP 4.3"H x 3.7"W x 1"D 11b.(Ship&Unit) models - Architects and Engineers Specifications The power supply shall be Wheelock POWERPATH"Series PS-8, or equivalent.The unit shall be stand alone power supply intended for powering fire alarm notification appliances via its own Notification Appliance Circuit(s) (NAC).The unit shall be UL 864 Listed for - power limited operation of outputs and comply with NFPA 70(NEC),article 760. The power supply shall support a full 8A of notification power even if the battery is in a degraded mode and only AC power is connected. The power supply shall be activated by a standard Notification Appliance Circuit(NAC) from any Fire Alarm Control Panel (FACP) or a "Dry contact"opening.The units shall be 8 ampere, 24 VDC, regulated and filtered, supervised remote power supply/charger. It shall operate over the voltage range of 8 to 33 VDC or FWR.The primary application of the unit shall be able to expand fire alarm system capabilities for additional NAC circuits to support ADA requirements and to provide auxiliary power to support system accessories or functions.The power supply shall provide four Class"B", two Class"A", or two Class"B"and one Class"A"NAC circuit(s). Eight Class"B"or Four Class"A"circuits shall be available with an optional PS-EXP module.The PS-8 unit shall supply up to 240 mA of auxiliary power that is available during both non-alarm and alarm or auxiliary power of not less than 2.5A at 24 VDC during non-alarm. The power supply shall be capable of charging batteries of up to 33 ampere hours per NFPA 72 at maximum rate of 0.750 Amps per hour. Input activation options shall be from not less than two NAC circuits or Dry Contact closures.These inputs shall have the capability of being directed to any combination of the four NAC circuit outputs. Each NAC circuit output shall be rated at 3 amperes for Class"B" applications or 3 amperes each for Class"A".The outputs shall be programmable to generate a steady or Temporal (Code 3) output and or a synchronized strobe or horn output.The power supply shall provide independent loop supervision for either Class"A"or Class "B"FACP NAC circuits and shall have the capability to"steer"all alarm or trouble conditions to either incoming NAC circuit.The units shall have common trouble terminals.The power supply shall be powered from a 120 VAC source with a current consumption of xx amperes max.The unit shall incorporate short circuit protection with auto reset.The power supply shall incorporate a built in battery charger for lead acid or gel type batteries with automatic switchover to battery back up in the event of AC power failure.The charger shall incorporate fused protection for the batteries and have the ability to report low battery and/or no battery condition(s). Standby current for battery back up shall be 0.129 Amps max.The power supply shall have the ability to latch trouble LED's so the circuit in trouble can be identified.The cabinet dimensions shall be 17"H x 15"W x 5.5"D. The power supply shall be Wheelock POWERPATH"Series PS-6,or equivalent.The unit shall be stand alone power supply intended for powering fire alarm notification appliances via its own Notification Appliance Circuit(s) (NAC).The unit shall be UL 864 Listed for power limited operation of outputs and comply with NFPA 70(NEC),article 760. The power supply shall support a full 6A of notification power even if the battery is in a degraded mode and only AC power is connected. The power supply shall be activated by a standard Notification Appliance Circuit (NAC)from any Fire Alarm Control Panel (FACP) or a "Dry contact"opening.The units shall be 6 ampere,24 VDC, regulated and filtered, supervised remote power supply/charger. It shall operate over the voltage range of 8 to 33 VDC or FWR.The primary application of the unit shall be able to expand fire alarm system capabilities for additional NAC circuits to support ADA requirements and to provide auxiliary power to support system accessories or functions.The power supply shall provide four Class"B, two Class"A", or two Class"B"and one Class"A"NAC circuit(s). Eight Class"B"or Four Class"A"circuits shall be available with an optional PS-EXP module.The PS-6 unit shall supply up to 200 mA of auxiliary power that is available during both non-alarm and alarm or auxiliary power of not less than 2.5A at 24 VDC during non-alarm. The power supply shall be capable of charging batteries of up to 33 ampere hours per NFPA 72 at a maximum rate of 0.750 Amps per hour. Input activation options shall be from not less than two NAC circuits or Dry Contact closures.These inputs shall have the capability of being directed to any combination of the four NAC circuit outputs. Each NAC circuit output shall be rated at 3 amperes for Class"B" applications or 3 amperes each for Class"A".The outputs shall be programmable to generate a steady or Temporal (Code 3) output and or a synchronized strobe or horn output.The power supply shall provide independent loop supervision for either Class"A"or Class "B"FACP NAC circuits and shall have the capability to"steer"all alarm or trouble conditions to either incoming NAC circuit.The units shall have common trouble terminals.The power supply shall be powered from a 120 VAC source with a current consumption of xx amperes max.The unit shall incorporate short circuit protection with auto reset.The power supply shall incorporate a built in battery charger for lead acid or gel type batteries with automatic switchover to battery back up in the event of AC power failure.The charger shall incorporate fused protection for the batteries and have the ability to report low battery and/or no battery condition(s).Standby current for battery back up shall be 0.130 Amps max.The power supply shall have the ability to latch trouble LED's so the circuit in trouble can be identified.The cabinet dimensions shall be 17"H x 13"W x 3.5"D. AWARNING:PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT.FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLA- TION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. NOTE:Due to continuous development of our products,specifications and offerings are subject to change without notice in accor- dance with Wheelock Inc.standard terms and conditions. Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 1 YEAR WARRANTY 59100 PS-6&8 06/11 NJ Location 273 Branchport Ave. Long Branch,NJ 07740 P:800-631-2148 F:732-222-8707 www.coopernotification.com / Cooper Notification is Wheelock'(MEDC) SAFEPATH' WAVES, COOPER Notification FAPS-C1 SIEMENS BATTERY&VOLTAGE DROP CALCULATIONS - FIRE ALARM SUBMITTAL Washington Square 85C Bakery FAPS-C1 SPECIFICATIONS FAPS-C1 BATTERY CALCULATIONS FAPS-C1. PANEL 24 Hours(A)Requirement for Standby Charge: PS-8 MODEL 15 Minutes(B)Requirement for Alarm Charge: 15%Design Voltage Drop(20%Max Voltage Drop) 20%(C)Spare Battery Capacity: 3.00 Amp Max Current Draw Per Output 0.13 Amp(F)Standby Total Current Draw 2.50 Amp Max Current Draw Per AUX Output 1.31 Amp(G)Alarm Total Current Draw 8.00 Amp Max Current Draw Per Panel 3.1 Amp Hr(H)Design Standby Charge=(A x F) 14 AWG Wire Gauge 0.3 Amp Hr(J)Design Alarm Charge=(B x G)I60 20.4 VDC Voltage at First Device' 0.7 Amp Hr(K)Additional Capacity Charge=(C x((A x FHB x G)160)) 0.13 Amp Standby Current Draw 4.1 Amp Hr(AH)Battery Amp Hour requirement=(H+J+K) 0.13 Amp Alarm Current Draw 7.0 Amp Hr Battery Size 32.0 Amp Hr Max Battery Charging Capacity FAPS-CI VOLTAGE DROP CALCULATION RESULTS PERCENT STANDBY ALARM PERCENT OUTPUT VOLTAGE CURRENT CURRENT CURRENT LABEL VOLTAGE DROP DROP DRAW DRAW DRAW OUTPUT-1 NC1-1- 3.02 Volt 14.78% 0.00 Amp 1.19 Amp 39.50% OUTPUT-2 NCI-2- 0.00 Volt 0.00% 0.00 Amp 0.00 Amp 0.00% OUTPUT-3 NC1.3- 0.00 Volt 0.00% 0.00 Amp 0.00 Amp 0.00% OUTPUT-4 NC1-I- 0.00 Volt 0.00% 0.00 Amp 0.00 Amp 0.00% AUX OUTPUT NC1-AX- 0.00 Volt 0.00% 0.00 Amp 0.00 Amp 0.00% Total Current Draw 0.00 Amp 1.19 Amp 14.81% FAPS-C1 VOLTAGE DROP CALCULATIONS .,RA.+A0,-ZW,271238111 OUTPUT-1 LABEL CD MODEL STANDBY ALARM DISTANCE VOLTAGE Alarm Voltage Drop=VD=R x la FAPS-C1 PS-8 ""i'^ -.�- Ater:,20.400 405.17 Ft (L)Total Circuit Length(One Leg) �i.:� 1 NCI-1-01 75cd E60H-24MCC-FW 0.189 186.50 ft 20.316 3.14 Ohm Wire Resistance Per 1000 Feet NCI-1-02 15cd STR 0.057 17.25 ft 20.002 2.54 Ohm (R)Total Circuit Resistance(Both Legs) NCI-1-03 30cd E60H-24MCC-FW 0.105 10.92 ft 19.973 0.00 Amp (Is)Total Current Draw(Standby) NCI.1-04 30cd E60H-24MCC-FW 0.105 25.25 ft 19.925 1.19 Amp (la)Total Current Draw(Alarm) NCI-1-05 30cd E60H-24MCC-FW 0.105 20.50 ft 19.865 17.38 Volt (20.4-(lax R))Applied Voltage at Last Device' NCI-1-06 30cd E60H-24MCC-FW 0.105 20.50 ft 19.811 3.02 Volt (VD)Voltage Drop NCI-1-07 30cd E60H-24MCC-FW 0.105 20.50 ft 19.757 14.78% Percent Voltage Drop NC1.I.00 15cd E60H-24MCC-FW 0.065 14.42 ft 19.720 39.50% Percent Current Draw Output-1 NC1.1-09 15cd STVVC 0.061 30.33 ft 19.684 NCI-1-10 30cd E60H-24MCC-FW 0.105 12.83ft 19.639 NCI-1-11 15cd E60H-24MCC-FW 0.065 23.75 ft 19.600 NCI-1-12 15cd STWC 0.061 8.83 ft 19.574 NCI-1.13 15cd STR 0.057 13.58 ft 19.558 OUTPUT-2 LABEL CD MODEL STANDBY ALARM DISTANCE VOLTAGE Voltage Drop=VD=Little P$PS-C1PS-8 1 W 20400..._. 0.00 Ft (L)Total Circuit Length(One Leg) 7m4" _,y.-�. w w 3.14 Ohm Wire Resistance Per 1000 Feet 0.00 Ohm (R)Total Circuit Resistance(Both Legs) 0.00 Amp (Is)Total Current Draw(Standby) 0.00 Amp (la)Total Current Draw(Alarm) 20.40 Volt (20.4-(lax R))Applied Voltage at Last Device' 0.00 Volt (VD)Voltage Drop 0.00% Percent Voltage Drop 0.00% Percent Current Draw Output-2 Unrestricted PROPRIETARY DOCUMENT FOR APPROVAL ONLY 7110/2019 • FAPS-C7 VOLTAGE DROP CALCULATIONS CONTINUED OUTPUT-3 LABEL CD MODEL STANDBY ALARM DISTANCE VOLTAGE Voltage Drop=VD=L'R'la FAPS-Ci ..-, 3 PS-n - P ' "20.400 0.00 Ft (L)Total Circuit Length(One Leg) 3.14 Ohm Wire Resistance Per 1000 Feet 0.00 Ohm (R)Total Circuit Resistance(Both Legs) 0.00 Amp (Is)Total Current Draw(Standby) 0.00 Amp (la)Total Current Draw(Alarm) 20.40 Volt (20.4-(la x R))Applied Voltage at Last Device' 0.00 Volt (VD)Voltage Drop 0.00% Percent Voltage Drop 0.00% Percent Current Draw Output-3 OUTPUT-4 LABEL CD MODEL STANDBY ALARM DISTANCE VOLTAGE Voltage Drop=VD=L'R'la FAPS-Cl PS-8 ai _ate �;. 20.400 425.00 Ft (L)Total Circuit Length(One Leg) 3.14 Ohm Wire Resistance Per 1000 Feet 2.67 Ohm (R)Total Circuit Resistance(Both Legs) 0.00 Amp (Is)Total Current Draw(Standby) 0.00 Amp (la)Total Current Draw(Alarm) 20.40 Volt (20.4-(lax R))Applied Voltage at Last Device' 0.00 Volt (VD)Voltage Drop 0.00% Percent Voltage Drop 0.00% Percent Current Draw Output-4 1 AUX OUTPUT LABEL CD MODEL STANDBY ALARM DISTANCE VOLTAGE Voltage Drop=VD=L'R'la FAPS-C1 PS-8 ° ;ti 20.400 0.00 Ft (L)Total Circuit Length(One Leg) 3.14 Ohm Wire Resistance Per 1000 Feet 0.00 Ohm (R)Total Circuit Resistance(Both Legs) 0.00 Amp (Is)Total Current Draw(Standby) 0.00 Amp (la)Total Current Draw(Alarm) 20.40 Volt (20.4-(lax R))Applied Voltage at Last Device' 0.00 Volt (VD)Voltage Drop 0.00% Percent Voltage Drop 0.00% Percent Current Draw Aux Output Note-1;24 Volt derated by 15%to 20.4 Volts. Note-2;Point to Point Voltage Drop Calculation. Note-3;Line Voltage Drop Calculation Unrestricted PROPRIETARY DOCUMENT FOR APPROVAL ONLY 7/10/2019